Home
MAC FAUCETS - ElectronicFaucets
Contents
1. PRESENCE NOT MOTION SENSORS AN IDLE OBJECT PLACED DIRECTLY UNDERNEATH SPOUT WILL IMMEDIATELY ACTIVATE FAUCET 2 Remove hands and water will cease to flow within 1 3 seconds 3 Ifhands are left underneath spout for 60 seconds water will automatically shut off To initiate flow again move hands away from faucet and start at step 1 4 When attempting to run water over small objects such as tooth brush it may be necessary to bring object closer to sensor to initiate water flow when water begins to flow move object back under stream of water Once user gets the feel of the faucet this step may be skipped Battery Replacement Instructions Batteries should provide 12 to 24 months of reliable service mostly depending on the make of battery used and the frequency of usage among other factors Battery weakness is indicated by constantly flashing led light within the sensor capsule When replacing batteries please follow these simple steps 1 Unfasten the 4 Philips screws at the top of the Faucet Automator FA444 TWS box proceed to step 4 2 Hold both water fittings down and carefully remove enclosure cover 3 Pull black battery holder out Be careful not to damage wire 4 Replace batteries with 4 AA Alkaline batteries make sure batteries are placed in their proper position 5 Re install battery pack into the Faucet Automator 6 Test faucet prior to placing enclosure cover back on 7 Place enclosure cover back on Fa
2. WITH POSTAGE AND HANDLING PREPAID ALONG WITH DATED PROOF OF PURGHASE THIS WARRANTY DOES NOT COVER INSTALLATION OR ANY OTHER LABOR CHARGES IT DOES NOT COVER SHIPPING AND HANDLING OF BOTH REPLAGEMENT PARTS AND RETURNED DEFECTIVE PARTS PRODUCTS OR COMPONENTS THAT HAVE BEEN ALTERED OR IN ANY WAY MODIFIED WILL NOT BE COVERED UNDER THIS WARRANTY REPLACEMENT PARTS ARE UNDER WARRANTY ONLY FOR THE REMAINING PERIOD UNDER THE INITIAL WARRANTY SOME STATES DO NOT ALLOW FOR EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE MAC FAUCETS 1289 North Post Oak Suite 160 Houston TX 77055 Tel 866 558 3200 Fax 310 919 3073 www macfaucets com email sales electronicfaucets com
3. least one minute each at high volume Purging water lines clears out dirt and debris that would otherwise find its way to screen filter within the solenoid valve Important Do not use pipe putty on water connection to faucet Pipe putty may cause immediate and irreversible damage to solenoid valve Please use Teflon tape instead Important If you do not plan on using faucet immediately after installation within 30 days of installation disconnect water supply lines to faucet and unload the water pressure that may be present in faucet This will keep new solenoid valve components from bonding together under high pressure Drawings below does not apply to FA444 41 and FA444 43 When installing your automatic Faucet make sure that sink is flush with counter top or below it If sink is raised above counter surface it may klock the sensor eye which in turn causes faucet ta malfunction If your application calls for a sink that is raised above counter make sure that the faucet is elevated at the same level MAC FAUCETS Installation Connection Drawings amp Rough In For Faucet Models FA444 11 FA444 12 FA444 15 FA444 31 FA444 63 FA444 41 FA444 43 awouy gt d nN 310102 wosUas awoyo NN 21902 wosuas 250H AANS 6uo uo 202 SOH 02 250H asus annoy zaDNn0 4 0144300 lt 2 anyon Bupha OMI Sd 2 1 43437 NN nN oro PT oin ya ce 7 AaUSOA 7 ABUSOM 45403 4 7 aaujor
4. MAC FAUCETS Owner s Manual Models FA444 Installation procedure 1 Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation Connect Faucet Automator model FA444 exactly as shown in drawing with sensor cable connection at bottom Failure to install Faucet Automator Model FA444 as shown will result in premature product failure and will void all warranties including extended warranty KIF using deck plate place plate on deck immediately over center sink hole Install new faucet by placing sensor wire and hose faucets with integral hose through the hole designated for spout Make sure that wire is not pinched or cut during installation Cutting or severely crimping sensor wire will cause faucet to malfunction and will also void all warranties Faucets with integral hose go to step 5 Affix faucet above plate if used Slide retainer washer over faucet shank with set screw deep placed in shank groove Insert sensor wire through special groove in washer Install retainer nut over faucet shank and tighten Remove the stainless steel braided hose from package fasten to faucet shank Go to step 6 Place rubber ring if used at the bottom of the faucet Affix faucet above plate if deck plate is used Use 2 screws 2 nuts and 1 retainer washer to fasten faucet to deck Locate spot on the wall that you feel comfortable installing Faucet Automator FA444 The spot s
5. aj Ja4033 5 4 Lauj y PIA Ua aAA pUBNESN PO woja 49799 0U01300 PMA UL 3AA puaupsnf po 3 ASZOM Pua SAA prpusjos SAPA pous ps pun 2 12330q puo sapaypoy Gasnay Buprey xog joJjuaj xog QUID pauadua 10 piod aAa daon T 0 pa gt uuo3 330N04 MAC RAUCRTS Rough In Faucets Water mixing valves Soap dispensers Faucet Hole 91 2500 Optional Soap Dispenser Hole 91 2300 Linear distance 1 5000 MIn between faucet hole and mixing valve hole 4 in min 20 in max 61 2500 LI dist Center to Center near agistance es 1 5 maxsimum Optionalt Above the Sink Woter Mixing alve Hole Sink Eawl Optionals OFF Body Lift Hole Off Body Draln Lift hole min dlamter 1 2 maximum diameter 1 1 2 maximum near distance From center oc sink 12 Faucet Hole WARNING Drop In sink may Interfere with sensor We recommend undermaunt sink or sink that Sink Bowl Is flush with counter top Maximum A Recommended A 1 0000 Counter Ay thickness 1 16 minimum LIMITED WARRANTY MAG FAUCETS WARRANT THIS FAUCET TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF PURCHASE MAG FAUCETS WILL REPLACE FREE OF CHARGE DURING THIS WARRANTY PERIOD PARTS THAT PROVE DEFECTIVE WHEN PROPERLY INSTALLED AND UNDER NORMAL USE AND SERVICE DAMAGE THAT OCCURS AS A RESULT OF ABUSE IMPROPER INSTALLATION ENVIRONMENTAL CONDITIONS OR IMPROPER APPLIGATION WILL VOID THIS WARRANTY PRODUCTS MUST BE SHIPPED
6. elected should be within reach of braided hose and sensor wire The selected spot should also be away from possible water contamination Mount Faucet Automator FA444 using supplied fasteners Be careful to mount box exactly as shown in drawings Install shank hose to Faucet Automator s water outlet top Align groove in sensor wire plug with pin in Faucet Automator FA444 sensor receptacle insert plug into receptacle fasten plug nut by hand only DO NOT CROSS THREAD Before proceeding to step 9 purge both hot and cold water lines for at least a minute each at high volume Purging water lines clears out dirt and debris that would otherwise find its way to screen filter within the solenoid valve 10 For single water source system install cold water supply hose to Faucet Automator s water inlet absolutely do not substitute hot water for cold as this may lead to scalding injuries 11 For dual water temp system install supplied T to Faucet Automator s water inlet Do Not Forget O ring 12 Install hot and cold water supply hoses to T in no particular order 13 Turn angle stops on Check for leaks Operation 1 Place hands under spout and directly in front of neck mounted sensor water will begin to flow out in less than a second water flow rate is governed by aerator and supply pressure water temperature is governed by selection at angle stops as well as water temperature in supply pipes PLEASE REMEMBER AUTOMATIC FAUGETS EMPLOY
7. olenoid valve send Faucet Automator for repair or contact an authorized plumbing professional Loud thump noise when faucet turns on and off This is an issue commonly associated with diaphragm type valves such as washing machine valves dishwasher valves etc The noise is generally present in the piping system Clear winner remedies are to 1 Lower water flow rate see flow rate adjustment section of this manual 2 Install hammer arrestors in close proximity to your automatic faucet Please consult a plumbing professional for this task 3 Problem may be caused by defective angle stop Replace angle stop Faucet continues to run for 30 60 seconds after hands are removes This very rare condition generally occurs due to over sensitivity on the part of the sensor system water pressure well above 100psi and or bathroom lighting setting This condition is always field curable 1 Turn down water flow rate see water flow rate adjustment 2 Replace aerator with 0 5GPM aerator when possible 3 Adjust sensor range to shorter See sensor range adjustment instructions Faucet runs if NO hands are present shuts off when hands are present under faucet works backwards Solenoid valve wire plugged in backwards Unplug solenoid wire from electronics rotate 180 degrees re insert the 2 plug ends together It is extremely important that you have flash light present when plugging solenoid wire correctly Runaway faucet water runs
8. out of faucet continuously longer than I minute does not stop 1 Make sure batteries are installed properly if A C make sure that power is present at wall receptacle DSC kD Make sure Faucet Automator is properly oriented on the wall see drawings below Make sure that sensor wire from faucet is plugged into Faucet Automator Make sure that sensor wire is not cut or broken specially near mounting nut and washer immediately below deck Make sure that water is plumbed correctly into Faucet Automator Water in to inlet water out from Outlet see Drawings If items 1 to 5 are OK please contact Factory for more tips on your particular installation Special Installation Note Automatic faucets are design to perform properly in a variety of applications There are some conditions however that may adversely impact the faucet s ability to perform Please note the following conditions prior to installing you new faucet 1 2 Your automatic faucet is designed for indoor applications This faucet is not designed for outdoor applications Avoid installing your new faucet in direct sunlight Direct sunlight that is focused on sensor will temporarily disable faucet s sensing capabilities If you choose to install your faucet to one water source only do not install to hot water only as this may result in scalding injury Important Before connecting supply line to Faucet Automator purge both hot and cold water lines for at
9. sten 4 Philips screws Trouble Shooting Faucet does not operate red light does not in response to approaching objects 1 Hands are not placed properly under spout and inline with sensor 2 Batteries need replacing replace batteries see battery replacement instructions 3 Batteries installed improperly in battery pack battery harness not plugged in properly see installation instruction and battery replacement instructions 4 Sensor wire loose unplugged plugged improperly plug sensor wire properly See installation instructions 5 Sensor range requires adjustment see sensor range adjustment instructions 6 Sink is raised above counter and blocking sensor s vision reinstall properly Faucet does not operate red light blinks in response to approaching objects No water very low water pressure in supply pipes supply valves closed Water pressure very high well above 115 PSI Screen filter severely clogged up Supply hoses severely kinked Batteries low or defective replace batteries i i Faucet operates on and off by it self 1 Sensor range adjusted too long and must be adjusted for shorter range See sensor range adjustment section of this manual 2 Objects such as sink lip may be present in close proximity to sensor 3 Rare Severe transient infrared signal present in the environment probably caused by a defective neon light Faucet leaks drips Constant leaks or drips indicate defective s
Download Pdf Manuals
Related Search
Related Contents
Samsung LA32A550P1F User Manual 業務規程 - コスモス・コーポレイション Zanussi ZOD580 User's Manual Usages des Technologies de l`Information et de la Communication Les défis de la gestion de classe au secondaire Redutores Industriais: Série X / Instruções de Operação / 2007-11 EVGA P55 Micro Motherboard 取扱説明善、本体表示などの注意書きに従った使用状態で保証期間内に Copyright © All rights reserved.