Home

stairville

image

Contents

1. To change current channel press Up or Down keys To leave this menu press Menu 4 2 DMX status You can check DMX status entering Unit Status gt DMX Signal If the DMX reception is OK the LCD will display DMX signal OK if it is something wrong with DMX signal the LCD will display No DMX signal Note Changing the status of DMX reception will be displayed blinking for 3 seconds e g when you turn on off the DMX console 4 3 Displaying unit temperature You can view the D6 10s internal temperature entering Unit Status gt Unit Temp 34Deg When the temperature exceeds 40 deg the cooling fan will start The fan speed will increase with internal temperature until 64 deg when the fan speed will be max If the internal temperature reach 95 deg D6 10s enter in overheat protection until the temperature go under 80 deg In this situation the channels will be shouted down and the LCD will display blinking Unit Overheated Unit temp 95 deg Note To avoid overheat do not cover the cooling fan and ensure adequate ventilation 0610s stairville Technical Specification AC INPUT LOAD Output Conector DMX Signal DMX conectors Dimension Weight 230V AC 50 60Hz 1 2 or 3 Phases Max 32A Phase 10A Channel 6 x Shucko 16A DMX 512 1990 Input XLR 3 pin Male Output XLR 3 pin Female 19 2U 483 L x 88 H x 430 D 10 8Kg
2. e Phase Note It is recommended to power up all three phases do not leave any dimmer section unpowered even you don t use it Once you have powered the unit the Phase indicator LED s will light and the LCD will display after a second STAIRVILLE D610s DIGITAL DIMMER This mean that D6 10s is ready to be used The Green LED s from front panel will show the intensity for channels Turn on the Circuit Breakers 1 for the channels you want to use and the lamps will light Note It is recommended to Set Up the unit see next pages before you turn on the Circuit Breakers 1 0610s StandBy Mode StdBy Stairville D610 Menu Pres StdBy Key Digital Dimmer Save Changes Yes Ok No lt Unit Setup Press Ok gt Down Up fs lt lt Unit Status Press Ok gt Down Up lt lt Test Ch 1 10 Press Ok gt Menu gt stairville Down Up Menu gt DMX Addr Chxx 01 le A lt Press Ok lt Down up Prehit Ch1 0 Press Ok lt y Down Up Ch1 Curve Linear Press Ok lt y Down y Up Ch1 Limit 100 Press Ok lt y Down Up Up Channell 1 100 Press lt y Down up A DMX Signal Ok Press lt Down Up L1 temp 32Deg Press lt fur Version 1 0 0 Press lt Down 0610s stairville 3 2 Preheat setup D6 10s have
3. individual channel preheat value which can be set in this way Enter Unit Setup gt Preheat Ch1 0 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt remember that you can toggle between channel no and channel value using lt and gt keys The preheat value for selected channel will blink Change the settings pressing Up Down keys If you want to change another channel preheat value press lt key and change the channel number When you have set all preheats to desired values press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without save the changes press lt key Note The max preheat value is 50 and in the On Off mode the preheat is shut off 3 3 DMX Address setup D610s have individual channel DMX address To set these addresses enter Unit Setup gt Ch 1 DMX Addr 01 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt Change the settings pressing Up Down keys If you want to change another channel address value press lt key and change the channel number Press Menu key and the Save Changes view will appear on LCD To save changes press Menu key to quit without save the changes press lt key Note Changing the the DMX address for Ch1 will modify all addresses If you wan
4. r serviceable parts inside do not attempt repairs please contact your local dealer To prevent fire or shock hazard do not expose this product under high temperature or moisture area CAUTION P BSBA This product is intended for indoor use only Disconnect the power when not use for extended period Do not dismantle or modify the unit Do not use the unit in places subject to excessive humidity vibration or bumps During use do not cover and ensure adequate ventilation 0610s stairville 2 Instalation 2 1 FrontPanel 1 2 3 4 5 2000 008888 00 og i nd goo 1 Circuit Breaker 2 Phase LED indicator a 2 le ce 3 Channel LED indicator g p 4 LCD Display 7 Control Keys 2 2 Rear Panel 10 11 12 er s PSI Sly mo 5 y 10 AC Power Outputs 11 Cooling Fan 12 Main AC Power Input 0610s stairville 2 Instalation 2 3 Power Up All indications that follows refers to the front panel and back panel from previous page Plug the 6 lamps into the Harting Plug 10 as is shown on the back panel Insert the DMX cable in the corresponding Inputs 6 Unwrap the power cord 12 and plug into a 3x230V Socket capable of delivering 32A per phase D610s have three section phases named L1 L2 L3 They can be powered in several modes each section powered by his individual Phase one section powered by one Phase and the other two powered by another Phase all sections powered by a singl
5. stalrville D 610s 6 Channel Digital Dimmer Pack _ fl user s manual 0610s stairville 1 Introduction 1 1 Features of D6 10s 1 2 General instruction 2 Installation 2 1 Front Panel 2 2 Rear Panel 2 3 Power Up 3 Unit Setup 3 1 Menu 3 2 Preheat setup 3 3 DMXAddress setup 3 4 Control curve setup 3 5 Test Mode 3 6 Limiter setup 4 Unit Status 4 1 Display channels values 4 2 DMX status 4 3 Displaying unit temperature 4 4 Software Hardware version 5 Technical specifications 0610s stairville 1 Introduction 1 1 Features of 0610s YN ss s S s S S ON ON Y ON Digital signal interface DMX512 1990 Each Channel have it s own DMX address Individual preheat on every Channel 0 15 Individual control curve on every Channel Switch Linear Sart Reglable voltage limit for every Channel Auto frequency tracking 45 65 Hz Test mode Overheat protection LCD Display Internal Temperature displaying Variable fan speed corresponding to internal temperature 0610s stairville 1 Introduction 1 2 General Instructions Thank you for your purchasing this product Please read through this operating instructions before installing or using your new product WARNING This product must be earthed After unpacking check for any obvious transit damage If damage is apparent return the unit to the place of purchase Do not make any inflammable liquids water or metal objects enter the unit No use
6. t to modify the address for each channel first set Ch1 address and after that set the others addresses 0610s stairville 3 4 Control curve setup D6 10s have 5 control curves for each channel Linear Sqrt Curve1 dimmer mode On Off switch mode The channel will be On Full when his value pass over 64 and the channel will be turned Off when his value pass under 32 Note The individual channel settings must be set before turning on the circuit breaker Some non dimming lamps may be damaged if they are used in dimmer mode To select the control curve Enter Unit Setup gt Ch Curve and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt the curve for selected channel will blink Change the settings pressing Up Down keys If you want to change another channel preheat value press lt key and change the channel number When you have set all channel curves press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without save the changes press lt key 3 5 Test mode You can test channels set individual channel value using Test Mode Enter Test Ch 1 0 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt remember that you can toggle between channel no and channel value using lt and gt keys The channel
7. value will start to blink Change the settings pressing Up Down keys If you want to change another channel value press lt key and change the channel number When you want to exit press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without save the changes press lt key user s manual 0610s stairville 3 6 Limiter setup D6 10s have individual voltage channel limit value for prolonging bulb life which can be set in this way Enter Unit Setup gt Limit Ch1 255 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt remember that you can toggle between channel no and channel value using lt and gt keys The Limiter value for selected channel will blink Change the settings pressing Up Down keys If you want to change another channel Limitter value press lt key and change the channel number When you have set all Limits to desired values press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without save the changes press lt key Note The min limiter value is 200 and in the On Off mode the Limiter is shut off 0610s stairville 4 Unit Status 4 1 Display channels values You can see value of each change of ID610s entering Unit Status gt Channel 1 68 and press Menu key The channel number will start to blink

Download Pdf Manuals

image

Related Search

stairville stairville stairville led bar stairville led stairville dmx-master i stairville mh-x25 stairville led par 56 stairville afh-600 dmx hazer stairville dmx joker software download stairville prometheus spark 1 stairville stage tri led bundle complete stairville dj lase 150-r mk-iii dmx ir stairville outdoor stage par 12x3w tri stairville dmx master 1 stairville led bar 240/8 rgb stairville sonicpulse led bar 10