Home
WIRELESS EXPANSION MODULE BELAIDIS IŠPLĖTIMO MODULIS
Contents
1. Power supply 7 15V 20mA max Number of Zones 2 Number of Outputs 2 Radio transmitter receiver frequency 866 1 MHz 869 5 MHz Range of Operating Temperatures 20 4 559C Dimensions 38x60x12mm Radio communication range 30 meters in premises 150 meters in open areas Compatible with security systems ELDES Wireless Allowable digital input voltage values 0 30V Output max parameters Current 500mA voltage 30V Fig No 2 Wireless Expansion Module EW1 DC C1 C2 Zi Z2 COM Package content AAD OB 1 EW1 wireless expansion module gty 1 2 User MANUAL issisnaiinnisinniisiiia ye Fig No 1 Connector functionality COM Common contact for zones outputs and power supply Z1 Z2 Zones Z1 and Z2 inputs C1 C2 Controlled C1 and C2 outputs tiav ee DC Positive power supply contact Power supply Restoring default parameters 1 Disconnect power supply 2 Short circuit connect connectors D1 and D2 3 Connect power supply till LED indicator starts fast several times blinking 4 Disconnect power supply 5 Disconnect connectors D1 and D2 3 Using software ELDES Configuration Tool Software ELDES Configuration Tool is used to work directly with central device of the security system which can be connected to the computer via USB port Using this software user can 1 Tobind new wireless expansion modules EW1 to central monitoring station 2 Toremove or replace old wireless expansio
2. Indicate as many zones as you want to change their statuses separating entries by symbol as shown in the examples provided 4 2 3 Adjusting controlled output names Controlled output names can be changed by sending the following SMS message XXXX_C1 CONTROLLER1 Here instead of Contoller1 enter the required controlled output name consisting of up to 10 cha racters and instead of C1 indicate the number of the corresponding output To change control led output names of more than one output separate entries by symbol for example XXXX C2 Controller2 C3 Controller3 4 2 4 Managing Controller Timer Wireless expansion module EW1 has 2 open collector controlled outputs They can be used to control various electrical devices such as electric pumps heating lighting etc When outputs are enabled it corresponds to output pins being pulled to common contact COM Enabling output by sending the following SMS message ui C1 VALDIKLIS1 Disabling output by sending the following SMS message Xxxx _c1 0FF C2 0FF Timer This feature allows any controlled output to be switched on or off for a specified time period The follo wing SMS command should be sent 4444 C1 0N 0FF vV MM Ss ON output enabled OFF disabled VV hours valid values 00 24 MM minutes valid values 00 60 SS seconds valid values 00 60 It is not allowed to have all values e
3. siun iama SMS inut XXXX STATUS FREE PASTABA Maksimalus belaid i rengini skai ius kuriuos galima prijungti prie centrin s apsaugos sistemos yra 16vnt 4 5 I pl timo modulio EW1 keitimas Norint pakeisti sen i pl timo modul EW1 nauju siun iama SMS inut XXXX REP ID lt ID5 Cia vietoje ID nurodomas senojo i pl timo modulio EW1 identifikacijos numeris ID o naujojo vieto je ID5 ym jimo Sistema automati kai suteikia buvusius senojo modulio EW1 nustatymus naujajam i pl timo moduliui 4 6 I pl timo modulio pa alinimas Norint pa alinti i pl timo modul EW1 i apsaugos sistemos siun iama SMS inut XXXX DEL ID ia vietoje ID nurodomas EW1 modulio kur norima panaikinti identifikacijos ID numeris I sistemos pa alintos zonos gali b ti naudojamos kitiems belaid iams renginiams prijungti VARTOTOJO VADOVAS EW1 V1 0 11 5 Papildoma informacija Atsakomyb s ribojimas Pirk jas sutinka kad sistema suma ina gaisro pl imo vagyst s ar kit rizik ta iau tai n ra draudimas ar garantija kad pamin ti veiksniai nejvyks bei nebus asmen su eidim ar turto praradimo ar sunaikinimo atvej ELDES UAB neprisiima jokios atsakomyb s uz tiesiogin ar netiesiogin al ar nuostolius taip pat negautas pajamas naudojantis sistema ELDES UAB atsakomyb kiek tai lei d ia galiojantys statymai nevir ija produkto sigijimo ka
4. W1 To delete wireless expansion module EW1 from the security system send the following SMS message XXXX DEL ID Here instead of ID indicate identification number ID of the module EW1 want to delete Removed from the system zones can be used to connect other wireless devices USER MANUAL EW1 V1 0 5 5 Additional Information Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not guarantee against such events ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system ELDES UAB liability according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with any of the cellular providers therefore is not responsible for the quality of cellular service Manufacturer Warranty The system carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt must be kept as a proof of purchase date The warranty is voided if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors Safety instructions Please read and follow
5. WIRELESS EXPANSION MODULE BELAIDIS I PL TIMO MODULIS EW1 Wireless expansion modules EW1 are wireless device with 2 input zones and 2 output controllers This module connects to ELDES wireless security systems and allows to connect variuos additional devices such as motion sensors sirens and etc Users have to con nect sensors to the EW1 contacts and bind it to the central device of security system by sending a corresponding command via SMS message or using software ELDES Configuration Tool It is possible to connect up to 16 wireless devices to the central security system at a time Maximum distance for wireless connection is 150 meters in open areas 1 Device Installation 1 Connect the circuit as shown in Fig No 2 Power supply cables are connected last 2 Bind the device to central monitoring station Use a software ELDES Configuration Tool or send corresponding SMS messages Please read software Help section or central system installation manual for more information Software ELDES Configuration Tool and installation manual can be downloaded for free in website www eldes lt The system automatically informs about successful unsuccessful bound device If attempt to bind is unsuccessful try to move sensor EWP1 closer to central monitoring station and bind anew 3 EW1 module is ready to use 2 Technical Specifications Electrical and Mechanical Characteristics
6. etaisus Esant jjungtam bet kuriam i valdikli atitinkamas i jimo kanalas sujungiamas su COM Prietaiso jungimas atliekamas siun iant SMS inut i C1 VALDIKLIS1 Prietaiso i jungimas atliekamas siun iant SMS inut 444 c1 0FF C2 0FE Laikmatis Taip pat leid iama bet kur i jimo kanal jungti arba i jungti tam tikram laiko tarpui iuo atveju siun iama SMS inut formatu 4444 c1 0N 0FF vV MM Ss ON bus jungtas OFF bus i jungtas VV valandos galimos reik m s 00 24 MM minut s galimos reik m s 00 60 SS sekund s galimos reik m s 00 60 Negali b ti reik m visi nuliai 10 4 3 Sistemos aktyvuot zon ir valdikli parametrai Norint su inoti sistemos aktyvi zon aliarm tekstus bei b senas valdikliams suteiktus pavadinimus siun iama SMS inut XXXX STATUS Sistemos atsakymas gaunamas SMS inute pvz Z1 0N OFF Zone1 Z2 0N OFF Zone2 C1 0N OFF Controller1 C2 0N OFF Controller2 Pastar ja informacine SMS inute nurodomi visi prijungti prie sistemos belaid iai ELDES renginiai ir esami jy parametrai D MESIO ELDES apsaugos sistema prane a apie visas aktyvias zonas Jeigu aktyvi zon yra daug apie visas jas informuo jama keliomis SMS inut mis 4 4 Laisv kanal skai iaus uzklausimas Norint su inoti kiek dar galima prie centrin s apsaugos sistemos prijungti belaid i rengini
7. i 24 simboli norimas aliarmo tekstas o vietoje Z2 nurodomas atitin kamas zonos numeris is aliarmo tekstas bus gaunamas SMS inute suveikus atitinkamai zonai Norint pakeisti daugiau nei vienos apsaugos zonos aliarmo tekst ra ai atskiriami simboliu pvz XXXX Z2 Tekstas2 Z3 Tekstas3 4 2 2 Zony jungimas i jungimas Galima pasirinkti kurias apsaugos zonas aktyvavus apsaug visoje sistemoje laikyti jungtas ar i jungtas Pagal pradinius gamintojo parametrus visos aktyvuotos zonos yra jungtos Bet kuri saugom zon galima jungti siun iant SMS inut formatu xxx 21 0N 22 0N 23 0N Bet kuri saugom zon galima i jungti siun iant SMS inut formatu 444 21 0FF 22 0FP 23 0FF Nurodoma tiek zon kiek j b sen norima pakeisti ra ai atskiriami simboliu 4 2 3 Valdikli pavadinim keitimas Tam tikro valdiklio pavadinimas kei iamas siun iant atitinkam SMS inut XXXX C1 CONTROLLER1 ia vietoje Controller1 vedamas iki 10 simboli norimas valdiklio pavadinimas o vietoje C1 nuro domas atitinkamas valdiklio numeris Norint pakeisti daugiau nei vieno valdiklio pavadinimus ra ai atskiriami simboliu pvz XXXX C2 tekstas2 C3 tekstas3 4 2 4 Valdikliy valdymas Laikmatis I pl timo modulis EW1 turi 2 atvirojo kolektoriaus i jimo kanalus kuriais galima valdyti vairius elektrinius pri
8. inos Korinio ry io paslaugas teikiantys GSM operatoriai n ra susij su ELDES UAB bendrove Tod l bendrov neprisiima jokios atsakomyb s u tinklo paslaugas jo apr pt bei funkcionavim Garantinis laikotarpis ELDES UAB suteikia sigytam produktui 24 m n Garantij Garantinis laikotarpis pradedamas skai iuoti nuo produkto pardavimo pirmam galutiniam vartotojui datos Garantija taikoma tik jei sistema buvo naudota pagal paskirt laikantis vis vartotojo vadovo instrukcij bei technin je specifikacijoje nustatyt s lyg ir maksimali leistin reik mi Pardavimo data laikoma ekio s skaitos ar kito pardavimo dokumento data Garantija taikoma tik kartu su pamin tais dokumentais pateikus u pildyt garantin talon Garan tija netaikoma jei sistema buvo paveikta mechani kai chemini med iag dr gm s korozijos skys i ekstremali aplinkos veiksni ar kitoki force majeure aplinkybi Saugos informacija Kad u tikrinti j s ir aplinkini saugum pra ome perskaityti ias taisykles bei laikytis vis vartotojo vadove esan i mon tavimo instrukcij ir nurodym Nenaudokite sistemos ten kur ji gali sukelti trikd ius ar pavoj Nemontuokite sistemos prie medicinin s aparat ros ar prietais jei to reikalauja j instrukcijos Nenaudokite sistemos sprogiose vietose Sistema n ra atspari dr gmei cheminei aplinkai bei mechaniniams poveikiams Neremontuokite sistemos paty
9. jungiami kontaktai D1 ir D2 3 Programin s rangos naudojimas Programin ranga ELDES Configuration Tool skirta tiesiogiai prisijungti prie centrinio apsaugos sistemos renginio kuris prie kom piuterio jungiamas USB laidu Su ia programine ranga vartotojas gali 1 Prie naudojamos centrin s apsaugos sistemos priri ti aktyvuoti ry naujus belaid ius i pl timo modulius EW1 2 Pa alinti ar pakeisti esamus belaid ius i pl timo modulius EW1 naujais moduliais 3 Konfig ruoti prijungt prie sistemos belaid i i pl timo moduli EW1 nustatymus 4 Realiu laiku steb ti EW1 belaid i i pl timo moduli zon bei i jimo valdikli b senas 5 Konfig ruoti visus apsaugos sistemos nustatymus ir parametrus Programin rang ELDES Configuration Tool galite nemokamai atsisi sti i interneto svetain s www eldes lt 4 Komandin s SMS inut s D MESIO Komandin s SMS inut s siun iamos bendruoju apsaugos sistemos telefono numeriu Visos SMS inut s prade damos pagrindiniu vartotojo 4 skaitmen slapta od iu pateiktuose pavyzd iuose naudojamas XXXX ym jimas Apatinis br k nys visur rei kia tarpel ty ra ant SMS inut vietoj io br k nio turi b ti daromas vieno simbolio tarpelis 4 1 Moduli priri imas prie centrin s apsaugos sistemos D MESIO Prie siun iant komandin SMS inut sitikinkite kad belaidis i pl timo modulis EW1 yra priju
10. lio ak tyvavim bandykite j aktyvuoti i naujo perkeliant ar iau centrinio apsaugos sistemos renginio 3 Modulis EW1 paruo tas darbui 2 Technin specifikacija Elektrin s ir mechanin s charakteristikos Maitinimo tampa 7 15V 20mA max Zon skai ius 2 I jim skai ius 2 Duomen perdavimo da nis 866 1 MHz 869 5 MHz Darbinis temperat r diapazonas 20 559C Matmenys 38x60x12mm Maksimalus bevielio ry io palaikomas atstumas Iki 30m patalpose iki 150m atvirose vietose Suderinamas su apsaugos sistemomis ELDES Wireless Skaitmeninio jimo leistin tamp reik m s 0 30V I jim maksimalios komutuojamos reik m s Srov 500mA tampa 30V Pav Nr 2 AAA eae egy Belaidis i pl timo modulis EW1 Pakuot s sud tis a 1 EW1 belaidis i pl timo moduli 1 vnt Bae 07 2 Vartotojo VAdOVAS sesseeeeee 1 VNT Pav Nr 1 Kontakt paskirtis COM Bendras kontaktas zonoms i jimams ir maitinimo altiniui Z1 Z2 Zon Z1 ir Z2 jimai o Ci C2 Valdikli C1 ir C2 i jimai IEA 5 DC Maitinimo altinio teigiamas kontaktas Maitinimo altinis Pradini parametr atstatymas 1 Atjungiamas maitinimas 2 U trumpinami sujungiami kontaktai D1 ir D2 3 jungiamas maitinimas tol kol kelis kartus gretai sumirksi LED indikatorius 4 Atjungiamas maitinimas 5 At
11. n modules with new ones 3 To configure settings of all added to the system wireless expansion modules 4 To watch the wireless expansion modules EW1 input and output zones status in real time 5 To configure security system settings Software ELDES Configuration Tool is a freeware and can be downloaded from website www eldes lt 4 Command SMS Messages ATTENTION send command SMS messages to the number used by the central device of the security system All SMS messages should start with the main 4 digit user password in the examples provided XXXX marking is used Undersco re symbol _ is used to represent space symbol 4 1 Binding Modules to the Security System ATTENTION before sending SMS message check whether wireless expansion module EW1 is connected to the power supply If it is not connected to the power supply binding to the central security system will be unsuccessful Binding of wireless expansion module EW1 to the central device of security system station is performed by indicating module identification numbers 1111 SET XXXX_SET ID1 05000001 Here ID1 means module identification number The system automatically provides 2 security zones and 2 outputs to the bounded module The system informs about this via SMS message for example 1D1 Z2 Z3 C1 C2 here instead of ID1 will be identification number of the module that you want to connect Z2 Z3 C1 and C2 the number of free zones and ou
12. ngtas prie mai tinimo altinio Kitu atveju daviklio priri imas prie centrin s apsaugos sistemos bus nes kmingas Moduli priri imas prie centrin s apsaugos sistemos vykdomas nurodant moduli identifikacijos nu merius 1111 SET XXXX SET ID1 05000001 ia ID1 i pl timo modulio identifikacijos numeris Priri tiems i pl timo moduliams EW1 sistema au tomati kai i skiria 2 laisvas apsaugos zonas bei 2 valdiklio numerius Apie tai sistema informuoja SMS inute pvz ID1 Z2 Z3 C1 C2 ia vietoje ID1 ra omas norimo prijungti i pl timo modulio identifi kacijos numeris Z2 Z3 C1 ir C2 atitinkamai i skirti laisv zon ir valdikli numeriai Vienu metu galima priri ti ir daugiau nei vien i pl timo modul EW1 Tokiu atveju komandin je SMS inut je atskiriami i pl timo moduli identifikacijos numeriai simboliu pvz XXXX SET ID1 ID2 ID16 4 2 Aktyvuot zon ir valdikli nustatymai Aktyvavus i pl timo modulius EW1 kiekvienam j automati kai suteikiamos 2 zonos ir 2 valdikli numeriai su pradiniais nustatymais t y tam tikru zonos aliarmo tekstu ir b sena bei valdiklio pavadinimu ir b sena Pradiniai gamintojo suteikti nustatymai gali b ti koreguojami VARTOTOJO VADOVAS EW1 V1 0 9 4 2 1 Aliarmo teksto koregavimas Tam tikros zonos aliarmo tekstas kei iamas siun iant atitinkam SMS inut XXXX Z2 TEXT ia vietoje Tekstas vedamas ik
13. ns of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt ce USER MANUAL EW1 V1 0 Belaidis i pl timo modulis EW1 tai ELDES belaid i apsaugos sistem priedas turintis 2 jimo ir 2 i jimo kanalus Jis skirtas pri jungti vairiems papildomiems renginiams judesio davikliams lauko sirenoms valdikliams kurie bus valdomi per centrin apsaugos sistem Vartotojui tereikia aktyvuoti modulio EW1 ry su centrine sistema SMS inute arba su programine ranga ir prijungti nori mus renginius prie atitinkam kontakt Vienu metu prie centrin s apsaugos sistemos gali b ti prijungta iki 16 belaid i rengini Belaid iai i pl timo moduliai EW1 nuo centrin s apsaugos sistemos gali b ti i d styti ne didesniu kaip 150 m atstumu 1 renginio instaliacija 1 Sujunkite grandin pagal pav Nr 2 pavaizduot schem Maitinimo altinio laidai prijungiami v liausiai 2 Aktyvuokite ry su centrine apsaugos sistema Tai galima greitai ir patogiai atlikti programine ranga ELDES Configuration Tool arba SMS inut mis Pla iau skaitykite programin s rangos Help skyrelyje arba centrin s sistemos instaliacijos vadove instaliacijos vadov bei ELDES Configuration Tool program galima nemokamai parsisi sti puslapyje www eldes lt Sistema automati kai informuoja apie s kming nes kming daviklio aktyvavim Jei sistema informavo apie nes kming davik
14. qual zeros 4 3 Reguesting system status information To find out the alarm texts and statuses of activated zones names provided to the controllers send the following SMS message XXXX STATUS You will receive system response via SMS message for example Z1 0N OFF Zone1 Z2 0N OFF Zone2 C1 0N OFF Controller1 C2 ON OFF Controller2 This informational SMS message indicates all wireless ELDES devices connected to the system and their current parameters ATTENTION System informs about all active zones If there are many active zones the system informs about all of them in several SMS messages 4 4 Requesting number of available slots to connect wireless devices To find out the number of available slots to connect wireless devices to the central device of security system send the following SMS message XXXX_STATUS_FREE NOTE maximum number of wireless devices that can be connected to the central device of the security system station is 16 units 4 5 Changing wireless expansion module EW1 To change an old module EW1 with a new module send the following SMS message XXXX REP ID lt ID5 Here instead of ID indicate identification number ID of the old module EW1 Identification number of the news module EW1 is indicated instead of ID5 marking The new module is provided with the same zone number with all previous settings valid for the old sensor 4 6 Deleting wireless expansion module E
15. s Pagal WEEE direktyv perbrauktos iuk li d s su ratais enklas rei kia kad nebetinkama naudoti gamin Europos S jungoje reikia atiduoti perdirbti atskirai nuo kit iuk li Copyright UAB ELDES 2010 Visos teis s saugomos Draud iama kopijuoti kaupti ar perduoti tretiesiems asmenims iame dokumente esan i informacij ar bet koki dokumento dal be i ankstinio ra ti ko UAB ELDES sutikimo UAB ELDES pasilieka teis be i ankstinio sp jimo tobulinti ar keisti bet kuriuos dokumente pamin tus gaminius taip pat pat dokument UAB ELDES deklaruoja kad EW1 belaidis i pl timo modulis atitinka esminius reikalavimus ir kitas 1999 5 EC direktyvos nuostatas Jos atitikties deklaracij galima rasti iame tinklalapyje www eldes lt ce VARTOTOJO VADOVAS EW1 V1 0 13 Made in Lithuania Pagaminta Lietuvoje www eldes lt
16. these safety guidelines in order to maintain safety of operators and people around Don t use the system where it can be interfere with other devices and cause any potential danger Don t use the system with medical devices Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system Any system repairs must be done only by qualified safety aware personnel The WEEE Waste Electrical and Electronic Equipment marking on this product see right or its documentation indicates that the product must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the system supplier or the local authority responsible for waste disposal in your area Copyright ELDES UAB 2010 All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB ELSDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this EW1 wireless expansion module is in compliance with the essen tial requirements and other relevant provisio
17. tputs provided by the system an You can bind more than one wireless expansion module at a time In such a case separate identification numbers by symbol for example XXXX SET ID1 ID2 ID16 4 2 Settings of Activated Zones and Outputs After activating wireless expansion module EW1 each of them is automatically given 2 zones and 2 outputs numbers with initial settings i e a particular zone alarm text and status particular output text and status USER MANUAL EW1 V1 0 3 4 2 1 Adjusting Alarm Text Alarm text of a particular zone is adjusted by sending the following SMS message XXXX Z2 TEXT Here instead of Text enter the required alarm text consisting of up to 24 characters and instead of Z2 indicate the number of the corresponding zone You receive this alarm text by SMS message when a corresponding zone is triggered To change alarm text of more than one zone separate entries by symbol for example XXXX Z2 Text2 Z3 Text3 4 2 2 Enabling Disabling Zones You can choose which zones after activating the alarm in the whole system will be enabled or disabled By initial factory default parameters all activated zones are enabled Any zone can be enabled by sending SMS message with the following format 4406 21 0N 22 0N 23 0N Any secured zone can be disabled by sending SMS message with the following format Xxxx 21 0FF 22 0FP 23 0FP an