Home
User Manual
Contents
1. Cancel key to return to normal operation
2. V the LCD will alternately display Lo in place of the Inside temperature and the LCD backlighting is turned off to extend battery life The wireless communication continues to operate but the range is reduced Batteries should be replaced with AA alkaline or lithium rechargeable batteries Lithium batteries can be recharged with a compatible charger b Fees Set To Inside AUTO4 Lo Schedule Day Th oH MENU N HOLD NENT ENTER bB Inside AUTO4 Schedule Day Th inn HEH i MENU M HOLD SEAT ENTER level typically 50 set by your installer Calibrating the Temperature Sensor Press and hold the Menu key until the temperature is displayed bo Press the Enter key to save the calibration and return to normal thermostat operation Use the Up and Down keys to set the correct temperature Displaying the Schedule Press and hold the MENU key until the Monday Day schedule is displayed Schedule Press and hold the Next key to sequentially display the Day and Night schedule for each day 3 Year Limited Warranty This is a Limited Warranty which gives you specif rights You may have other rights which vary from state to state l For a period of three years from the date of purchase any malfunction Senedule Mo Night caused by factory defective parts or workmanship will be corrected at 9 00 no cost to you See the complete Warranty at eControlsUSA com E PM Press the
3. Wireless Thermostat For Direct Damper Control User Manual Model T200WLO1 Made in USA Improved Comfort Your wireless thermostat and damper have been installed and will automatically control airflow to maintain the temperature you set and eliminate the discomfort caused by overcooling and overheating Energy Savings Excess airflow that causes overcooling or overheating is automatically redirected to areas that need it the thermostat is satisfied quicker and the HVAC system operates less The thermostat has an Off position that can shut the airflow down to provide even greater energy savings when the office or space is not being used The night setback feature works the same way and provides added energy savings Temperature Setting Indicates Daytime or Nighttime operation Up and Down keys are used to set the temperature and setting options Current inside temperature Indicates the Schedule or Permanent Hold mode bB Inside AUTO4 SYSTEM key selects Automatic airflow control based on your temperature setting or Off Menu key used to set time of day and the daytime schedule Installer key used to select options Hold key used to switch between Schedule and Permanent Hold operation Next key used when setting time of day and schedules www eControlsUSA com Battery compartment 2 AA batteries L Enter key used when setting time o
4. f day and daytime schedules S eControls 26945 Cabot Road Bldg 101 Laguna Hills CA 92653 949 916 0945 Fax 949 458 8502 Operation Your thermostat controls the WCD Damper installed above the ceiling diffuser via an RF wireless data link It monitors the space temperature and the temperature you set and sends instructions to the damper telling it that the space is too cold or too warm The damper has a temperature sensor that monitors whether the HVAC system is in heating or cooling mode Airflow is periodically increased or decreased until the comfort level you set is achieved This thermostat and damper cannot offset lack of HVAC system heating or cooling capacity Operating Modes The thermostat and damper control airflow in three modes Daytime operation Nighttime operation and Off In Daytime operation airflow is controlled by the temperature setting the inside or space temperature and whether the HVAC system is in heating or cooling mode In Nighttime operation airflow is reduced to the preset Night level to save energy and in Off mode the airflow is reduced to the preset Off level to save energy Daytime Operation In Daytime operation the thermostat adjusts airflow to maintain the space temperature at the comfort setting Nighttime Operation Nighttime operation automatically occurs in the Schedule mode and lowers the airflow to save energy Off Operation In Off the thermostat lowers airflow to reduce ener
5. gy consumption Off mode can be set by the System key or can be programmed to selected days in the daytime nighttime schedule Setting the Temperature Press the Up or Down key to change the temperature setting The LCD light comes on when a key is pressed qm CLI set Inside AUTO Hold in n aa MENU ROLD AEAT ENTER Selecting OFF or Automatic Operation Press the System key to toggle between Auto and Off qm E set Inside OFF lt 4 Hold mn ee MENU HOLD nana ENTER Selecting Hold or Schedule Operation Press the HOLD key to toggle between Hold and Schedule operation HHN Inside AUTO4 Schedule Option oi ai MENU HOLD NEXT A Overriding the Night or Off Operation Pressing the Up or Down key to adjust the temperature when in the nighttime schedule or Off mode returns the thermostat to Daytime operation After two hours the thermostat returns to the Nighttime schedule or Off mode 18 Inside AUTO4 Hold Option iD ggm MENU HOLD J NEXT ENTER Setting the Time of Day To set the time of day and the day of the week press the Menu key and the LCD will display the hour Use the Up and Down keys to set the hour ID AM Press the Next key to set the minute Use the Up and Down keys to set the minute 08 Press the Next key to set the day of the week Use the Up and Down keys to select the day Th 08 Press the Enter key when complete The display retur
6. ns to the normal time and temperature display bB b H k Di ay Night Hold Th iG MENU HOLD NEXT ENTER Changing the Daytime Schedule To change the Daytime schedule press and hold the Menu key until the LCD displays the Daytime start hour Schedule Day 7 AM r CANCEL NEXT ENTER Use the Up and Down keys to set the hour for starting Daytime operation If you do not want Daytime operation on certain days see Setting Days Off Press the Next key to set the Use the Up and Down keys to set the minute for starting Daytime operation The minute can be set to 00 15 30 or 45 minutes Schedule Day 40 Press the Next key to set the hour for ending Daytime operation and starting Nighttime operation Use the Up and Down keys to set the hour for starting Nighttime operation Schedule Night E PM Press the Next key to set the minute for starting Nighttime operation Use the Up and Down keys to set the minute for starting Nighttime operation The minute can be set to 00 15 30 or 45 minutes Schedule Night BID Press the Next key to select the days of the week for the schedule just entered Schedule Night Mo TuWeTh Fr Sa Su BID All of the days will be displayed Use the Next key to move between the days The number in the upper right corner shows the day of the week being selected or deselected 1 is Monday 2 is Tuesday etc Press the Up or Down keys to
7. toggle the selected day on or off The schedule will be applied to the days displayed Ifa different schedule is required for other days program the remaining days for the second schedule Press the Enter key when complete The display returns to the normal time and temperature display The factory default schedule is shown below Start Day Stop Day Schedule Schedule Monday 7 00AM 9 00PM Tuesday 7 00AM 9 00PM Wednesday 7 00AM 9 00PM Thursday 7 00AM 9 00PM Friday 7 00AM 9 00PM Saturday 7 00AM 9 00PM Sunday 7 00AM 9 00PM Setting the OFF Days You can set some days that you will be off and the airflow will be reduced on those days to the preset Off level to save energy Press the Menu key twice to start the schedule sequence Schedule Day Tr r Press and hold the Up key to set OFF 12 midnight as the start hour for Daytime operation Schedule Day OFF Press the Next key to select the days for the Off schedule All of the days will be displayed Use the Next key to move between the days The number in the upper right corner shows the day being selected or deselected 1 is Monday 2 is Tuesday etc Press the Up or Down keys to toggle the selected day on or off The Off days will be the days displayed Sa Su OFF The example above shows the Off days are Saturday and Sunday On those days airflow is reduced to the preset Off Low Battery Indication When battery voltage drops from 3 3V down to 2 5