1. V Workbooks Add xlWBatWorkSheet V Workbooks 1 WorkSheets 1 Name praxis Some Data end V Visible True Except ShowMessage Excel could not be opened on this machine End end fA Liberty Script Designer ANewScript ll xi File Edit Search Yiew Dun Tools Help A a He Standard Additional Win32 System Data Access Data Controls Dialogs Win 3 1 Dream 4 gt es ua Sc 1 pene h PHamBane e ggal IL C A_TempStuff ANewScript BasicForm ybs VBasicForm vbs Object Inspector EI Button TButton we Properties Events Dregtusg ofeg t Y l DragKind dkDrag yariable declarations DragMode dmM anual public AnInteger EK ton ro Height 24 Eeer Left 56 en e _ AE oO ModalRestmiNone _ Nee Button SE Caption Returns sets the text displayed in an objects s title bar or below an object s icon The Liberty Script Designer The Script Designer is a separate application that can be started from within Praxis It can be started from the Scripts gt Design A Script menu of the Main Form Script Designer is essentially a complete development environment with a component palette graphical designer forms text editors for entering Code and a project manager It is much like a streamlined version of the Borland Delphi development environment Version 2 of the Script Designe
2. Stepped Tones 1lch asynch stiSinStepped2A 11 Stepped Tones 2ch asynch stiWavS 12 WAV File synch stiWavA 13 WAV File asynch stiWhite 14 White Noise stiPink 15 Pink Noise stiWaveletBurst 16 Wavelet Burst synchronous stiNone 99 None Acquisition types example usage Praxis Acquisition acqTimet acqTimel1 0 Time Domain ich acqTime2 1 Time Domain 2ch acqTimeMLS 2 Impulse Response via MLS acqTimeChirp 3 Impulse Response via Chirp acqFft1 4 Spectrum FFT ich acqFft2 5 Spectrum FFT 2ch acqRtal 6 Spectrum RTA ich acqRta2 7 Spectrum RTA 2ch acqFreqRespCpx 8 Freq Response MAG and PHASE acgqFreqRespMag1 9 acgqFreqRespMag2 10 acqFreqRespMon 11 Freq Response MAG lch Freq Resp MAG 2ch Freq Response Liv Monitor acqIimpulseMon 12 Impulse Resp Live Monitor acqIimpedance 13 Impedance acqCompTrack1 14 Component Track 1ch acqCompTrack2 15 Component Track 2ch acqFRandHD 16 Freq Resp and distortion via Chirp Farina s method acqFRandIMD 17 Freq Resp and IM difference distortion via Chirp acqDispTime 18 Displacement vs Time NOT IMPLEMENTED acqDispFft 19 FFT of displacement NOT IMPLEMENTED acgqFft2Cpx 20 2 CH fft complex normalized acqWaveletMaxLevel 21 Wavelet Max Level capability acqWaveletSingleFreq 22
3. Wavelet distortion vs level acqWaveletDist 23 Wavelet Distortion vs Frequency NOT IMPLEMENTED acqWaveletDist3D 24 Wavelet Dist vs Level vs Freq NOT IMPLEMENTED acqCustom 99 Custom Acquisition PostProcess types example usage Praxis PostProcess ppMath ppNone 0 None ppReMap 1 Re Map to new Freqgs ppFilter 2 Filter ppMath 3 Math ppPaste 4 PasteOver ppSmoothing 5 Smoothing ppFft 6 Fft pelfft 7 Inverse Fft ppTSP 8 Thiele Small Extract ppWF 9 CSD Waterfall pestep 10 Step Response ppHilbert 11 Hilbert Transform ppSchroeder 12 Schroeder Curve ppGroupDelay 13 Group Delay ppPolar 14 Polar Data Compilation PPpFRZ 15 Combination of Frequency and Impedance data PPETC 16 Analytic Signal ETC ppPCepstrum 17 Power Cepstrum transform ppQAnechFB 18 Quasi Anechoic Bass Restoration ppProgAvg 19 Progressive Averaging ppTailCorr 20 Response Tail Correction ppUser 99 User Defined Stepped Tone Increments used in method ChangeStepF Specification swmLog 1 swmLin 0 TFormStates is a record type to be used with the Praxis FormStates property for saving and restoring the visibilities of the Configure forms and the Levels Form Often these forms are not needed to be seen in a script and only clutter the screen they can be hidden via the script see the Show procedures in General
4. function PointInRect const x y integer ARect TRect boolean For graphic programming Returns true only if the point defined by x y is within the ARect area see Delphi docs function PrimaryPlot TDataPlot This returns the Primary Plot linkID 9000 object which is where newly acquired data is placed during a measurement For instance when you make an RTA measurement PRAXIS draws the RTA spectrum result in the Primary Plot The function PrimaryPlot can be used interchangeably with the PRAXIS property PrimaryPlot example usage PrimaryPlot AutoAll DelphiScript Autoscales the primary plot Praxis PrimaryPlot AutoAll this DelphiScript code does the same thing PrimaryPlot AutoAll VBScript function RealVal Mag Angle double double returns the Real part of the complex number Mag _Angle angle in degrees function ReadPortByte PortAddr Integer Byte provides DIRECT READ of hardware ports of the computer Use extreme caution this lets you do things that Windows does not normally allow and can cause trouble if used incorrectly PortAddr is the address of the port be sure to give the decimal not hexadecimal value for the port Also see function LPTin function RoundToDecimalPoints x double DecPts integer double returns the given value x rounded to DecPts decimal points function safediv num den double double gives num den but is protected from divide by zero instead returns a huge value
5. Provides direct WRITE ACCESS to an LPT parallel printer port A printer should NOT be connected to that port This is intended for controlling external hardware using the 8 data lines of the port This works only in Windows2000 or WindowsXP and not in all computers Jor more reliable I O use a Labjack device See NumberOfLPTPorts function Mag Real Imag double double returns the magnitude of complex number Real i Imag procedure MicDatFileSensitivity Adj fn string dB double Adjusts the Microphone data correction file fn so that it causes the mic s sensitivity to be dB higher The file will be modified and a backup file of the original will be created function MoveOctaves Oct Value double double takes Value and changes it by Oct octaves i e if Oct is 1 doubles it if Oct is 1 cuts it in half Function NowDoing string see SetDoing below function NumberOfLPTPorts integer returns the number of LPT parallel printer ports in the computer Works in Windows2000 or WindowsXP only function OctaveChange Ffrom Fto double double A moving x octaves going from Ffrom to Fto result is x function OperatingSystemName string returns a string identifying the Windows operating system in use function PadOut s string slength integer string returns string of length returns a string based on s that is exactly slength characters long extra space at end is filled with blanks
6. function safeExp x double double returns ex protected from overflow error function safeExp2 x double double returns 2 x protected from overflow error function safelnp x double double returns base elogarithm but protects from overflow error by returning huge values function safelog x double double returns base10 logarithm but protects from overflow error by returning huge values function safelog2 x double double returns base2 logarithm but protects from overflow error by returning huge values function saferound x double integer returns value x rounded to the nearest integer but limits at 2 31 function safeTenToPwr x double double returns 10 x with math error protection procedure SavePraxisConfig Fname string Saves the current confguration settings to a reloadable configuration file in the fully specified path and filename file Fname procedure ScriptConfig Fname string Avery handy procedure When your script starts you can call ScriptConfig with the name of a PRAXIS software configuration file that is in the same folder as your script PRAXIS will then save its current configuration as existed when the script started and load the new configuration making a huge number of program settings for you When your script or any other scripts called from our script exits PRAXIS will then automatically restore its original configuration without further programming effort
7. lets user use the dialog to change settings procedure CopyFileFromTo ff ft string ff and ft are complete filenames with paths Copies the file ff to a new file ft complex math functions using real imaginary format The type CXN is a record type defined by CXN record rep imp double end function cpxadd x y CXN CXN x y function cpxsub x y CXN CXN x y function cpxmult x y CXN CXN x y function cpxdiv x y CXN CXN x y function cpxscale x CXN s double CXN x s function cpxinv x CXN CXN 1 x function dBV x double double returns 20 log x Result will be limited to 1E5 function EngFloatToSir x double string returns x in Engineering notation for example 0 012 will give 12 00m function FloatLimits max value min double double returns value if it is within min max Else returns min or max function FloatToMinStr x double digs integer string limits output to digs digits after decimal and if any trailing characters are zeroes they are removed function GetScriptParameters string Returns the string if any set by a previous call to SetScriptParameters and then empties the string Used to send a string value between scripts when one script starts another using Praxis NextScriptToRun function ImagVal Mag Angle double double returns the Imaginary part of the complex number Mag _Angle angle in degrees function IncDecString s string GoUp boolean string Used to
8. Praxis AuxPlotFormDimensions var Left Top Width Height integer All arguments to these methods must be variables of the script To set the values assign the variables as desired before calling the method To leave any of them unchanged set the corresponding variable s to a negative value After the method executes the variable will be loaded with the current positive value of the plot setting You can obtain parameters of the data that is currently obtained in a normal PRAXIS plot by using the procedure GetDataStats var DS DataStats This is given a data record of type DataStats that will be filled by the procedure The DataStats record is defined as follow DataStats record datatype string example TimeDomain etc NumberOfPoints NumberOfFields integer HorizontalMin HorizontalMax double range over which the horizontal axis is defined Description string DateAcquired MonthAcquired YearAcquired word HourAcquired MinuteAcquired SecondAcquired word SampleRate integer WindowLeft WindowRight double window edges for time domain data end AddAPlotToPlotSet DP TDataPlot See Plot Sets below AddMultiPlotFile FileName string Adds a single data file to be included in the set of Multi traces for the plot If UseMultiPlot is true and the first field of the data file is compatible with the first field of the data held by the plot a trace will be shown from this file You can also load a list of such file names usin
9. If Fname is blank or an empty string then PRAXIS will still save its current configuration and restore it after your script is done Procedure SetDoing s string sets an internal string called DOING to the uppercase converted version of string s The internal string accessed with functions IsDoing IsInDoing or NowDoing is useful within scripts to keep track of what the script is trying to do at any time and to determine different actions to be performed within event handler procedures An event handler could be entered at various times while the script is running and the string variable will let your script code keep track of changing situations Examples SetDoing Measuring First the internal DOING string is set to MEASURING FIRST If IsInDoing Measuring then true because the DOING string contains MEASURING If IlsDoing Measuring Second then false because DOING is not MEASURING SECOND LogString NowDoing shows the DOING string in a debug message procedure SetScriptParameters s string used to send parameters such as the name of a file or directory between scripts using a string The next script to run can access the string by using the function GetScriptParameters which then empties the string function ShellExecute hwnd HWND lpOperation LPCTSTR IpFile LPCTSTR lpParameters LPCTSTR lpDirectory LPCTSTR nShowCma INT HINSTANCE Use this Windows API function to sta
10. Much of your code will be grouped into sets of Event Handlers Of course some of these events will occur multiple times and under different circumstances so you need to keep track of what conceptual processes are happening as execution of your script progresses This is needed so that your Event Handlers can adapt their response to the changing situations You can do this using your own variables or with the built in global functions SetDoing IsDoing IsinDoing and NowDoing You shouldn t call Praxis Start and Praxis Stop within the same script procedure as this will more or less stop the acquisition process before it has collected anything Remember that these operations really start or end thread processes code that happens essentially at the same time as other program operation occur within Praxis and then almost immediately returns control to your code You should instead Stop or Start Praxis data acquisitions in response to events If you want to track the sequence of code execution in your script project insert LogString commands in select places within your code and then run your script LogString pops up a special debugging form that shows the message specified by your call and does this without interrupting script or PRAXIS program flow For instance the call LogString now in the ButtonClick handler DelphiScript LogString now in the ButtonClick handler VBScript will result in
11. number Tonelndex next to be output in channel OutChan 1 or 2 Returns 1 if an invalid parameter is used FreqRatio double Read Write The ratio less than 1 typically about 0 94 between the two frequencies in a dual frequency chirp used to measure intermodulation distortion and frequency response using an acqFRandIMD acquisition This acquisition type is experimental at this time InterSilence double Read Write The minimum time in seconds between successive stimulus bursts for non consecutive stimulus types Can be used for cooling off or to wait for reverberation decay MaxDistOrder integer Read Write This determines the maximum distortion order 2 through 10 that will be analyzed using the Chirp Stimulus and the acqFRandHD or acqFRandIMD acquisition types MaxWindow boolean Read Write Relevant when using the Chirp Stimulus and the acqFRandHD or acqFRandIMD acquisition types When true the time windows used to measure each product will be automatically adjusted to the longest time period that could isolate the separate products If false the windowing for the time domain impulse reponse will apply which can be used to remove echoes in some measurement circumstances and may be needed in cases where impulse responses decay slowly In neither case will the windowing period used be longer than the calculated longest time period for product isolation MisSeqLength integer Read Write Length of MLS sequence to be used wi
12. scripts should normally call Praxis UseSingleSoundDevice to assure one soundcard is being used Value must be supported by current hardware 48000 is always supported PowerAmpdBGain double Read Write The voltage gain of the power amplifier at the present setting of its volume control This is used in the Wavelet Burst output capability measurements and to determine linear drive levels PowerAmplifierPeakVCap double Read Write The maximum voltage output peak that the power amplifier following the stimulus output of the Audpod is capable of This is used in the Wavelet Burst output capability measurements and to determine linear drive levels StimulusVCap double This function returns the maximum linear voltage that the stimulus output of the AudPod is capable of according to the most recent calibration for the selected soundcard For most stimulus types this voltage will be reached when the Output Gain of stimulus channel 1 is set to 0dB UseAverage boolean Read Write Can be used to enable or disable the averaging function of data acquisitions This duplicates the function of the Averaging On checkbox of the Acquire configuration form Primary Plot Formatting via the Praxis Object Prefix these properties and methods by the indentifier Praxis Note These all act on the Primary Plot Many of these can also be done using Properties and Methods of Plot Objects HorizontalCenter double Read Write Sets the center of t
13. 78cB InputPeak Index integer double Read Peak value of the last buffer from the Output A D This gets cleared on some internal operations Index indicates the channel InputPeakRaw Index integer double Read Peak raw value of the last buffer from the Output A D This is normalized to 1 0 full scale input InputResolution integer Read Write A D sample resolution for specialized use only Works ONLY if the user has first selected separate sound cards or separate sample resolutions for record and play using the menus in the Levels window For normal uses scripts should first call Praxis UseSingleSoundDevice and then set sample resolution using Praxis OutputSampleRate Value must be supported by current hardware 16 must always be supported Only values of 16 or 24 are supported InputRms Index integer double Read Rms value of the last buffer from the Output A D This gets cleared on some internal operations Index indicates the channel InputSampleRate integer Read Write A D sample rate for specialized use only Works ONLY if the user has first selected separate sound cards or separate sample rates for record and play using the menus in the Levels window For normal uses scripts should first call Praxis UseSingleSoundDevice and then set sample rates using Praxis OutputSampleRate Value must be supported by current hardware 48000 is always supported InputSelect Index integer TInputSelect Read Write Select the
14. AudPod mode only Value used for correcting slight gain differences in the probes ProbeResistor double Read Write AudPod mode only Values of the internal series resistors in the probes OBSOLETE USE ProbeResistorFor ProbeResistorFor index integer double Read Write Value of the total series resistance in each lead of the indicated probe 1 or 2 ReferenceResistor double Read Write Value in ohms of the reference resistor value to be used in making impedance measurements Running boolean Read Indicates whether the Acquisition engine is running Many script properties and methods can be used only when this value is false SavePlotFormat Plot TDataPlot filename string Saves the formatting information scales etc to the Plot format file named in filename If no path information is given the path of the current script is used Plot format files with suffix pf_ allow one set of data to use the formatting saved previously from a similar data plot ScriptsDir string This function returns the top directory containing all Scripts For AudPod mode it is Praxis VCLScripts For Demo mode it is Praxis DemoScripts Use it to start other scripts for example Praxis NextScriptToRun ScriptsDir WizardModels need to close this script for next one to start See also the Path function ScriptPath string This function returns the path less the file name and extension of the currently running sc
15. BSet CSet should be changed to ASet BSet or CSet e CreateObject can be used to create objects that will be implicitly freed when no longer used So instead of procedure proc var l begin TList Create try do something with finally Free end end you can write procedure proc var l begin CreateObject TList do something with end e Built in function Evaluate can be used to interpret string as program code during runtime of a program and execute the code contained in the string For example you can write script like Evaluate ProcNames Proclndex and the procedure which name is specified in ProcNames Proclndex will be called e Built in directive UseUnit can be used to dynamically add to uses section any unit at runtime For example the following script if FileExists Update pas then begin UseUnit Update pas Evaluate Update DoUpdate end checks whether the unit named Update pas exists and if so calls DoUpdate method from there e UnloadUnit directive unloads any unit added by uses section or with UseUnit call Copyright c 1997 1999 Dream Company How Scripts are Stored and Organized All files related to a single script should be contained in a separate subdirectory also called a Folder In Full Mode the script directories are most conveniently stored as subdirectories of the directory named VCLScripts which itself resides under the same directory as the Praxis exe
16. UnitsOfMeasure Field integer string Returns a string identifying the units of measure Such as V dB Pa etc for the field of this plot UpdatePlot This procedure redraws only the graph area of the plot marker readouts etc are not redrawn UseCustomBitmap Boolean Read Write Specifies whether to use a bitmap file for the background of plots Otherwise the background is drawn as a solid color using BackColor UseMarker Index integer boolean Read Write Determines if the indexed marker 1 to 5 is enabled UseMultiPlot boolean Read Write Determines whether Multi curves from compatible data files should be shown with the data contained in the plot ValOfY y integer DfieldNum integer double This function returns the vertical data value dB volts etc for the given field number of the data in the plot that would correspond to the vertical graphic position y It is useful to for instance find the implied data value at a mouse postion on a plot The vertical graphic position 0 is the top of the bitmap see BmpCanvas above position 1 is the next line down etc DFieldNum is indexed here starting at 0 and for time domain data is 0 or 1 For frequency domain data do not use a value of 0 as that is used for the frequencies ValueAtPoint point integer Field integer double This function returns the data value of Field Field for point index point Use the PointFromX or PointFromDomain functions to find t
17. You should leave the Script Designer open while testing your script in Praxis This allows you to go back make adjustments or corrections and try again You can launch your script into PRAXIS by using the Script Designer s Run menu or button If your script has more than one Form also include UseUnit statements such as UseUnit Unit1 pas or UseUnit Unit1 vbs in the FormCreate method for each form so that all other forms are made visible to each other and can refer to each other in their code In DelphiScript all procedures and functions should be written as object methods of a form For instance make a Procedure TForm1 MyProcedure rather than a global Procedure MyProcedure When you need to refer to form methods OTHER THAN EVENT HANDLERS that are in other forms refer to those methods using the other form s Unit name rather than the Form name Unit1 MyProcedure rather than Form1 MyProcedure EXCEPTION For event handlers that are automatically created by the editor such as Button1Click sender you should however use the Form name to specify it for example Form1 Button1Click nil This can be confusing but if PRAXIS doesn t seem to respond to your procedure name try changing the reference between the unit name and the form name In PRAXIS s Main Form set the Config gt Preferences gt Strict Script Running menu to checked whenever you are testing your script This wil
18. a number of these type files in a complex script e pas or vbs or js these files generated by Liberty Script Editor contain the Object Pascal DelphiScript VBScript or JScript files which make up the script code There can be a number of these files any other bitmap or rich text or other type files which may be used in the particular script code Calling COM servers from Scripts Very large portions of the Delphi Object Pascal language are usable from your script This includes the ability to make Windows API calls including COM methods That means that scripts can send Praxis data to other applications or can control other hardware if it is run by a COM server You can use such features to control other hardware switches relays turntables using third party data control devices digital I O provided those devices provide a COM server for access For an example of controlling a COM server the following script will start up Microsoft Excel if it is installed on the computer Procedure TDWForm OpenExcel const XlSheetType xlChart 4109 xlDialogSheet 4116 xlExcel4IntlMacroSheet 4 xlExcel4MacroSheet 3 xlWorksheet 4167 X1LWBATemplate xlWBATChart 4109 xlWBATExcel4IntlMacroSheet 4 xlWBATExcel4MacroSheet 3 xlWBATWorksheet 4167 Var V variant begin Try if VarIsEmpty V then begin V CreateOleObject Excel Application
19. a program crash DemoMode boolean Read Write True if the AudPod was NOT detected when Praxis was started or has been removed DemoRtaMode boolean Read Write Demo mode if true will use mixer settings which the user has set up for RTA operations DensityOfAir double Read Write In grams per cubic meter nominally 1210 Used in some processing calculations DomainView dvType Read Write Selects whether the Primary Plot shows the last acquired Frequency domain data if still available or the last Time domain data Similar functions as done by the Time Frequency Button of the Praxis Main Form ExitPraxisDirect This procedure causes an immediate shutdown both the script and the PRAXIS program itself without asking any questions no chance to save files or configurations Use with caution FormStates TformStates Read Write This value can be saved to a global variable at script startup time in the InitScript event handler and restored when the script closes to preserve the Users s chosen visibilities for the Stimulus Acquire and PostProcess Configure forms and the Levels Form You may want to hide those forms use the Show procedures to minimize screen clutter while the scripts are running GetConfiguration FileName string This procedure attempts to load the configuration file which is named in FileName To load the Praxis ini default Configuration file set FileName to an empty string GetHardwareDependent Fi
20. data in certain PostProcess frequency domain operations PostProcSource TDataPlot Read Write This accesses the PostProcess Source plot Make sure the plot you assign to this still exists PostProcTarget TDataPlot Read Write This accesses the PostProcess Target plot If assigned nil a new plot will be created and displayed when the PostProcess operation is applied PostProcTimeGainDb1 double and PostProcTimeGainDb2 double Read Write These properties control the gain that is applied if the TimeGainMode property is set to 2 Specify dB on the Postprocess configure form for time domain operations PostProcUseFlexWindow boolean Read Write shows or controls whether FFT postprocess operations will use the FlexWindow to allow for gradual transitions from windowed to unwindowed operations PostProcWindowType TWndKinds Read Write The type of data window to use in PostProcess operations such as PostProcess FFT RemapFreqFormat TRemapFormat Read Write For the ReMap PostProcess RemapListFile string Read Write List File to use for ReMap PostProcess Must have complete path and extension RemapNumberOfPoints Integer Read Write Used with ReMap PostProcess RemapSampleRate Integer Read Write Used when RemapFreqFormat is rflfftCompat SchroederFilter TFilterShapes Read Write The filter shape Butterworth brick wall used to bandlimit Schroeder curve PostProcesses SchroederFilterCenter double Read Wri
21. gt Preferences gt Strict Script Running menu H You can now use the very handy EditRealSpin or NVC controls in your scripts for numerical entry by your users e The PRAXIS main form s Scripts menu provides options for zipping a script directory to a compact form or for installing such a zipped script This makes transferring or sending scripts between installations or users much easier e You can also now launch your script in PRAXIS from a button the Script Designer simplifiying the test and debug cycle for script development There is also built in support that can copy an existing script folder under a new folder name so that the existing script can be used as a starting point for the new script This is often the easiest way to generate a customized PRAXIS script simply create a new one based on one which is similar to the one you want to create and edit it to provide your new behaviour or features To use this just select Copy an existing Script Folder in the form that appears when you use the Script Designer s File gt New PRAXIS Script menu Alternately you can have the Script Designer create a new skeletal script for you based on some selectable parameters You can find more information and links about Praxis script writing at http www libinst com praxis_script_writers htm Using VBScript When you start the Liberty Script Designer and choose New PRAXIS Script from its menu you h
22. in units of time WindowLefi Index Integer double Read Write Reads or sets the windowing start edge to the assigned value for use in subsequent transformations to frequency domain such as by FFT Index should always be 1 WindowRight Index Integer double Read Write Reads or sets the windowing stop edge to the assigned value for use in subsequent transformations to frequency domain such as by FFT Index should always be 1 XFromDomain domain double integer This function returns the horizontal coordinate in the BmpCanvas of the data using the given domain value in Hz or sec This function may be useful for making custom annotation on a graph drawn by Praxis XFromPoint point integer integer This function returns the horizontal coordinate in the BmpCanvas of the point whose domain value would be indexed by point This function may be useful for making custom annotation on a graph drawn by Praxis YAtPoint point integer DfieldNum integer TraceNum integer integer This function returns the vertical coordinate within the BmpCanvas of the data point indexed in the array starting at 0 corresponding to the DFieldNum assuming that it is now plotted on the graph TraceNum value is not used and can be set to 0 This function may be useful for making custom annotation on a graph drawn by Praxis
23. input source with the AudPod for each channel channel 2 can not be set in Synchronous mode InterSilence double Read Write The minimum time in seconds between successive stimulus bursts for non consecutive stimulus types Can be used for cooling off or to wait for reverberation decay LatestInputHeadroom chan integer double This function returns the decibels of headroom from the last acquistion in input channel chan 1 or 2 It can be used to determine whether the InputGain setting can be increased for an identical input Mic1UsesProbe boolean Read Write If this is true and when an Audpod is used Praxis will obtain Mic1 microphone input signals from the Probe1 jack rather than the tip connection of the Mic jack This avoids the extra preamplification and bias voltage that is used at the microphone jack allows for approximately 12dB greater signal headroom and allows use of balanced microphone inputs The calibration data for Mic still is applied Mic2UsesProbe boolean Read Write If this is true and when an Audpod is used Praxis will obtain Mic2 microphone input signals from the Probe2 jack rather than the tip connection of the Mic jack This avoids the extra preamplification and bias voltage that is used at the microphone jack allows for approximately 12dB greater signal headroom and allows use of balanced microphone inputs The calibration data for Mic2 still is applied This is intended for when two balan
24. is OFF 1 means postive 2 means negative three means either For instance if the Triggering threshold is set to 1V and TrigPolarity is 2 then acquisition will be triggered when the voltage at the designate input crosses through 1V at the specified slope direction TrigPosPercent double Read Write The position in the acquisition time period at which the triggering event will be placed before display or transformation For instance suppose that TrigPosPercent is 25 Then when the triggering event occurs in the first following display of the Primary Plot 25 percent of the information or transformed by FFT or RTA will be from the time before the event and 75 will be for the time after the event If the acquisition were acqTime1 and the acquisition were to be 100msec long then the event would be found at the 25msec point TrigSlope integer Read Write Specifies the direction the signal must be going in order to cause a trigger to occur 0 means rising 1 means falling 2 means either TrigThreshold double Read Write This is used with TrigPolarity to determine the time domain value at which triggering can occur provided the slope as the point is approached is as specified by the TrigSlope value UseAutoStart boolean Read Write When true can activate an Automatic acquisition start at the time specified in AutoStartTime UseAutoStopTime boolean Read Write When true acquisitions will automatically stop after AutoStopTime
25. is binary IrPolarityPositive boolean This function returns true If the plot has time domain data and its polarity is positive otherwise false valid only for impulse response data IsInAPlotSet boolean See Plot Sets below IsInSamePlotSet DP TDataPlot boolean See Plot Sets below IsolateFromPlotSet See Plot Sets below IsWithinLimits var BadFreq double Mask integer EvalAbsolute boolean CurvelD integer LimitIndex integer boolean This function is used to perform Pass Fail evaluations These evaluations can be performed only from a script The function returns true passing if the trace identified by CurvelD the Field of the data lies in its displayed region entirely above the lowerLimit curve for the specified LimitIndex and below the upperlimit curve for the specified LimitIndex Otherwise the function returns false failing That is the function is true when the curve being tested is within the limit curves Any region in which the data curve or the limit curves is not defined will be considered to be passing Mask should be set to 3 for evaluation both upper and lower limits to 1 for evaluating only relative to a lower limit and to 2 for evaluation relative to only an upper limit If EvalAbsolute is false then the curve being evaluated can be shifted vertically to try to make it fit within the limit curves otherwise it will be evaluated at its absolute settings LoadMultiPlotList ListName string This procedure attemp
26. language and the components used are Delphi VCL components other languages such as VBScript and JavaScript can be used to develop code if you wish Most procedures and functions that are built into Delphi are also usable in a PRAXIS script even when the script is programmed in languages other than DelphiScript The Script Designer provides specific support such as automatic generation of skeletal scripts for the VBScript and DelphiScript languages Developing scripts with the version 2 Script Designer and with PRAXIS v2 is considerably easier than with the previous versions For example e When creating a new script the Script Designer will automatically set up your script directory and will provide a template or basic structure for your DelphiScript or VBScript even including procedure or subroutine bodies for handling the PRAXIS events e The Script Designer makes it easy to edit or create a Picture omp and Description rtf file for your script so that your script can be easily found and launched from PRAXIS Script Launcher e The Script Designer now provides a Cut Copy Paste Find popup menu when you are editing within your script text to simplify editing H PRAXIS scripts can now operate with strict error checking which causes an error message if any undeclared variables are encountered This speeds debugging and helps prevent hard to find bugs in your code The error tolerance can be selected via the Main Form s Config
27. of the Shift Alt and Ctrl keys at the time that the mouse button was last clicked in the plot s graph e f Shift was pressed then ThisPlot MouseButtonShift AND 1 1 e f Alt was pressed then ThisPlot MouseButtonShift AND 2 2 e f Ctrl was pressed then ThisPlot MouseButtonShift AND 4 4 MouseDomain double Read Reads the horizontal data value usually Hertz or seconds of a plot s graph where the mouse was last clicked Does not work correctly for waterfall or polar plots MouseNormal This procedure disables mouse clicks in the plot form fromto triggering a MouseClickInPlot event in a running script To enable this event use the EnableMouseClickEvent procedure of this Plot object MouseValue index integer double Read Reads the value of the data traces for the data field corresponding to index at the horizontal position in the plot where the mouse was last clicked Read this in response to a MouseClickInPlot event See MouseNormal and EnableMouseClickEvent above MultiPlotTraceColor index integer TColor Read Write Sets or reads the color of the multiplot trace having the specified index the index is the order in which the trace was added to the MultiPlot Trace list NewTimeDomain Fields Points Rate integer This procedure fills the plot s data with a blank time domain record of the specified number of points and of up to two fields traces Rate is the sample rate of the new data to be created so the time
28. plot object which as been clicked and the data values in the plot corresponding to the horizontal position of the click can be read using the plot s MouseValue property Properties and Methods of the Praxis object Prefix these properties and methods by the indentifier Praxis Example Praxis Stimulus stiChirp DelphiScript or Praxis Stimulus stiChirp VBScript The Properties and Methods have been divided for convenience into the following groups General Data Manipulation Input Output Control Primary Plot formatting via the Praxis object Stimulus control Acquisition control PostProcess control General Prefix these properties and methods by the indentifier Praxis AbortPraxis This procedure causes Praxis to close after checking with the user first Acquisition integer Read Write See Global Constants AllAcqProcStopped boolean This function returns true only if the data engine is not running AutoLevel Attempts to automatically adjust the input levels AudPod mode only AuxPlot TDataPlot Read Provides access to the Auxiliar plot a special plot used to present data that is compiled in real time from a succession of acquisitions in the Primary Plot Callnputindex integer Read Write Identifies the AudPod input selection which will be used as the Cal input for normalized measurements such as Frequency Response or Impedance This value is NOT saved in the Praxis Ini value and defaults to 1 Pro
29. procedure sets the current data to be the persistent Hold data a special multiplot used to quicky define and show a reference plot when variations are being monitored HorizontalCenter double Read Write Sets the center of the horizontal display range time or frequency of the Plot You can also do this using the Plot HorizontalCenter property You should normally set the HorizontalSpan first HorizontalLog boolean Read Write Sets or reads a value reflecting whether frequency domain data uses logarithmic format if true or linear format if false Should always be set False for time domain data HorizontalSpan double Read Write Sets the span of the horizontal display range time or frequency of the Plot HorizontalStart double Read Write Sets the start of the horizontal display range time or frequency for the Plot Must be less than the Horizontal Stop value HorizontalStop double Read Write Sets the end of the horizontal display range time or frequency for the Plot Must be more than the Horizontal Start value InvertPhase boolean Read Write causes any displayed phase values to be offset by 180 degrees inverted ImportMLSSA FileName string IsASCII boolean true This procedure is intended to import data files from another measurement system However its implementation is not yet complete nor tested so results will vary IsASCII should be true if the file type is text and false if the file to be read
30. scripts you should avoid them This is because every name within such a construction will be assumed to be a property or method of the PRAXIS object instead of a method or variable that may be of an item in your script code In DelphiScript code If you find that your code does not seem to be responding to the user s use of menus buttons etc check for unmatched Begin End pairs existing just before the event handler code that does not seem to be working The Script Designer will not indicate unmatched Begin End pairs and when such code is executed entire procedures can become inactive Working with NVCs or EditRealSpin Components Beginning with PRAXIS version 2 and Liberty Script Designer v2 you can now design with PRAXIS s exclusive Numerical Value Controls NVCs in your scripts These controls called EditRealSpin or ERS devices in the design environment provide remarkably versatile and intuitive control over numerical values a function that is frequently needed during configuration of 4 27 89 med measurement or processing parameters EditRealSpin controls have a number of properties that should be configured at design time to simplify operation of your script for your users and to minimize the need for range checking in your script code You can also configure these properties at run time but that may cause confusion because some property settings are not compatible with others These are the EditRealSpin pr
31. seconds have passed since the acquisition has started UseAverage boolean Read Write Reads or specifies the state of the On checkbox in the Averaging region of the Acquire Configure form this checkbox controls whether acquisition averaging is to be used UseMaxHold boolean Read Write When true single channel FFT and RTA curves will maintain a MaxHold response curve of the highest value encountered at each frequency point during the current acquisition UseMinHold boolean Read Write When true single channel FFT and RTA curves will maintain a MinHold response curve of the lowest value at each frequency point encountered during the current acquisition WaveletAnalysisBandwidth double read write The octave fractional bandwidth overwhich a spectrum will be analyzed near fundamental and harmonic center frequencies in Wavelet type acquisitions WaveletAvgOptions integer read write A binary set of flags sum the options desired used to control how averaging is adjusted when searching for maximum levels with Wavelet Burst stimuli 1 constant number of averages 2 force an even number of averages 4 scale the number according to output stimulus level 8 scale the number of averages according to the relative response in the reference response if used All are adjusted relative to the number of averages and the level of the first level and first frequency in the search WaveletDistResolution double Read Write Also can be call
32. the specified message appearing in the debug form which will appear if not already visible Multiple messages will appear in order in which they occurred If you want to track the sequence in which event handlers are called add a LogString call to each exception don t put LogString calls in FormCreate event handlers Never have your code wait for anything If your code waits PRAXIS also waits and nothing gets done Instead if you need to have time pass before continuing set a Timer component and put the next part of your process in the event handler for the timer Or better still put the next part of your process in the event handler of an event that you know happens at at time when your process can continue To enter code for event handlers of Script Designer visual components like buttons checkboxes etc double click on the component and you will be transported to an event handler cody block for the component If you need to create or edit a code block for a different event handler press the F11 key to access the Object Inspector form use the Events tab and double click on the event name for which you wish to code In the Script Designer use the F12 key to change between display of your visual form and its code block e You cannot create properties in your forms or objects in Praxis Scripts Instead use functions or variables While DelphiScript constructions such as With Praxis Do are legal in Praxis
33. when InVoltage is used to read single ended inputs non differential inputs using an index less than 8 This gain setting can be used to optimize the resolution and range of the differential voltage inputs It does not affect the scale of the voltage that is read For instance if the value of AnalogGain is set to 1 and a 2 0 volt difference is applied to the corresponding set of Al terminals the value read by InVoltage will be about the same than as if AnalogGain had been set to 8 But in the first case the measurement resolution will be 9 8mV while in the second case the resolution would be much more precise at 1 22mvV Valid values that can be assigned are 20 16 10 8 5 4 2 or 1 See the description of the LabJackS InVoltage property for usable voltage ranges with each gain setting Example LabJackS AnalogGain 9 10 DelphiScript LabJackS AnalogGain 9 10 VBScript LabJackS Counter integer read This property returns the current value of the LabJack s internal counter This hardware counter is incremented on a rising edge at the LabJack s CNT terminal Triggering signals should pull the CNT line low then high for each increment NumberOfPulses LabJackS Counter DelphiScript NumberOfPulses LabJackS Counter VBScript Procedure LabJackS ResetCounter This procedure resets the Labjack counter back to zero The LJ_ global functions The second more versatile method of controlling a LabJack device from PRAXIS is t
34. wnH7h wnHM wnHMh wnBG wnBGh wnFT wnETh wnHN wnHNh None Rectangular Blackman Harris Half Blackman Harris Hamming Half Hamming Hodie7 Half Hodie7 Hodie5 Half Hodie5 Bingham Half Bingham FlatTop HalfFlatTop Hann Half Hann These are used with Praxis s SetWindowType procedure and with its WindowType and PosProcWindowType properties Object Types SG TDataPlot this is the type used for Praxis Plots Never use Create Destroy or Free with one of these Use Praxis properties Praxis PostProcSource Praxis PostProcTarget Praxis PrimaryPlot Praxis AuxPlot to access their properties Use function Praxis GetNewPlot to open a new plot Use Praxis DeletePlot or Praxis CloseAllSecondaryPlots to remove secondary plots Global Functions These functions may be useful for math operations and for text string formatting in Praxis script programming function Angle Real Imag double double returns angle in degrees of complex number Real i Imag function AmplifiedOutVoltage dBOutLevel double double returns the peak possible output voltage after the power amplifer which has gain of Praxis PowerAmpdBGain assuming that Praxis OutputGain for the desired channel is set to dBOutLevel Possible power amplifier clipping is not considered Procedure BitmapFileToPrinter s string UsePrintDialog boolean true prints the bitmap file to the current default printer If UsePrintDialog is true it
35. Liberty Instruments Inc Praxis Script Programming Guide V2 2 January 2005 IL Liberty Script Designer ANewScript C 4_TempStuff ANewScript BasicForm y bs 7 Object Inspector E Also included 18 storage and retri Buttont TButton E script s form position to save ii option explicit include this line s this greatly reduc variable declarations About WEE 3 ie Ee EE 4 Object Pascal andian tet eebe belt re al nds ae tek EE RE 4 Differences between DelphiScript and Object Dasecal 5 How Scripts are Stored and Organtzed nenn nnt 7 Calling COM Servers from Scripts cceccceeeeeceeececeeeeeeaeeeeaaeeeeeeeceaeeeseaeeeeaaeseeeeeseaeeseaeeseneeseneees 8 The Liberty Script Designen ea aae nent EE 9 Script Design Some Tips and Noteworthy Comments 10 Working with NVCs or EditRealSpin Components ssseesseeseeseeeeseeeeenesnesnennnnennnnnnennene 12 Praxis Specific Methods Functions Procedures and Properties eseeeseesseeeseeeeeere reres 13 Global Constants and Types c ccceecceceeeeeseeeeeeeeeceaeeeeaaeeeeaaeseeeeeeeaeessaaeseeaaeseeeeseaeeesaeeseneeeeaes 14 Global FUNCOMS anserinae ie ketigi se meet dethe ia hid een eens eed ate eat ie 17 Controlling LabJack hardware ssssesssssssesssessssssissiesetnstnnntnnttnntttnnttnnttnntnntnnnnnnnnntnnnnn nnen nnt 22 Events Triggered Within Praxis ce ceceeeeeseeeeeenneeeeeenaeeeeeeaaeeeseeaaeeeeeeaa
36. Plot objects with it or do things like Praxis PostProcSource MyNewPlot DelphiScript You can use MyNewPlot wherever a parameter expects a TDataPlot object MyNewPlot CopyPlot Praxis PrimaryPlot copies the data and formatting from PrimaryPlot Praxis DataFileLoad MyNewPilot C XLERB SomeData px2 Saved Praxis DataFileSave MyNewPlot C SomeFolder SomeData px2 MyNewPlot FormLeft 100 To delete the plot use Praxis DeletePlot MyNewPlot DON T FREE OR DESTROY IT To see if it still exists use something like DidntDeleteItYet Praxis PlotExists MyNewPlot Properties and Methods of Plot Objects Prefix the following properties and methods using the complete indentifier for the plot Examples Praxis PrimaryPlot Print psBW PrimaryPlot Print psBW using the global function PrimaryPlot Praxis PostProcSource Print psBW MyPlot Praxis GetNewPlot MyPlot Print psBW Setting Position and size of the Plots Do not use the properties Top Height Left or Width for the Plot Objects Instead use the special integer properties FormTop FormHeight FormLeft and FormWidth Handling the LiveTime LivelR and AuxPlot The position and dimensions Left Top Width and Height of these three special plots can be read or set using these methods Praxis LiveTimeFormDimensions var Left Top Width Height integer Praxis LivelRFormDimensions var Left Top Width Height integer
37. The lower frequency below which tail correction will be applied using TailCorrLowerSlope TailCorrLowerSlope double Read Write The slope in dB Octave at which the response curve will be tapered off below TailCorrLowerFreq TailCorrUpperFreq double Read Write The upper frequency above which tail correction will be applied using TailCorrUpperSlope TailCorrUpperSlope double Read Write The slope in dB Octave at which the response curve will be tapered off above TailCorrUpperFreq TimeChan1From integer and TimeChan2From integer Read Write Used with the Time Domain Channels postprocess These properties specify where the data to be placed into the Target Plot s new channel 1 or 2 is to come from i e from the Source plot or the original Target plot O indicates that the curve is to come from the Source plot and 1 indicates it is to come from the Target plot A value of 2 none can also be specified for the TimeChan2From property to indicate that the Target plot is to contain only one channel after the postprocess Also see the TimeChan1UseChan property TimeChan1UseChan integer and TimeChan2UseChan integer Read Write These properties specify which channel 1 or 2 of the From plot is to be used for the new Channel 1 or 2 of the Target plot when a Time Domain Channels postprocess operation is performed The From plot for each channel to be put into the Target Plot is specified in the TimeChan1 From or TimeChan2From prop
38. abJack Corporation LabJack U12 DB25 Pinouts 1 DO 6 D5 11 5V 16 GND 21 D11 2 D1 7 D6 12 5V 17 GND 22 D12 3 D2 8 D7 13 5V 18 D8 23 D13 4 D3 9 NC 14 GND 19 DY 24 D14 5 D4 10 5V 15 GND 20 D10 25 D15 When controlling the LabJack device from PRAXIS there are two possible sets of controls that can be used one is the LabJackS object and the other is via the global LU_ functions It is strongly recommended that you use only one of these command sets within a PRAXIS script for controlling digital lines as mixing calls between the two sets can cause incorrect configurations for the LabJack s digital I O pins The LabJackS or LJ Object The first and easiest method of controlling a single LabJack device is to work through the built in software object called LabJackS or LJ This LabJackS object can be used only when just one single LabJack device is connected to the computer and provides for very simple but more limited input output control The names LJ and LabJackS both indicate the same instance of the same object and can be used interchangeably If you refer to this object using LJ however be careful not to confuse that object or its methods with the set of functions whose names begin with LJ_ The LJ object is not the same and is not entirely compatible with use of the LU_ functions When the LabJackS or LJ object is used digital bits DO throu
39. abJack to be logic input signals PRIOR TO USING THIS PROPERTY THE CONFIGURATION DIRECTION OF THESE LINES MAY NOT BE KNOWN DO NOT ATTEMPT TO DRIVE THESE LINES HIGH FROM AN EXTERNAL SOURCE UNLESS YOU HAVE FIRST USED THIS PROPERTY ONCE OR UNLESS YOU CONNECT TO THE LINES VIA SERIES PROTECTION RESISTORS 1000 ohms recommended Example OutsideWorldByte LabJackS InByte DelphiScript result will be no higher than 255 OutsideWorldByte LabJackS InByte VBScript LabJackS OutlO line integer integer write This indexed write only property is used to configure and define the logic state of the protected screw terminal lines OO 101 102 or IO3 When this property is set that one line will be configured as an output line the remaining three are unchanged If the written value is gt 0 the line will be set otherwise it will be cleared Example LabJackS OutlO 0 1 DelphiScript sets IO0 to the output high state LabJackS OutlO 3 0 clears 103 to the output low state LabJackS OutlO 0 1 VBScript sets IOO LabJackS OutlO 3 0 clears 103 LabJackS InlO line integer integer read This indexed read only property is used to configure and read the logic state of the protected screw terminal lines lOO 101 lO2 or IO3 When the value of this property is referenced that one line will be configured as an input line and the returned value will be either 1 if the line was high or 0 if the line was low Exampl
40. ave the option to automatically create a skeletal DelphiScript or a VBScript The Designer can create a new Script for you including a form and a code section and blocks for all of PRAXIS built in events If you choose Delphi you can code in PascalScript which is the only supported script type that operates as compiled code within Praxis the others are interpreted This makes DelphiScript run faster and it has more direct control But many programmers are more familiar with Visual Basic of which VBScript is a subset Those programmers should probably not have difficulty writing PRAXIS scripts in VBScript but there may be some difficulty in knowing the meaning of various properties of the VCL components made available in the Script Designer These components are the same as those in Borland s Delphi and documentation for this is available from Borland in the form of a help file D5VCL_P ZIP at http info borland com techpubs delphi v5 updates pro html It is also possible to make and run scripts coded in other script languages JScript Python Perl but generation of these scripts is not automated by the Script Designer Object Pascal If you choose to create a new Delphi Application you can code in PascalScript which is the only supported script type that operates as compiled code within Praxis the others are interpreted This makes DelphiScript run faster and it has more direct control And the programmer of Praxi
41. be 2 at Praxis startup Same as RefCalSource ClearValueHold This procedure clears the ValueHold array of variant values see entry for ValueHold below CloseAllSecondaryPlots Closes deletes all secondary plots Be sure you are finished with the plots and the data within them before using this ClosePostProcessReports Closes the small forms which show Thiele Small extraction or Room Acoustics reports This may be wanted within a script to minimize screen clutter ConfigAcqPosition var Left Top integer This procedure can be used to change or read the Left or Top positions of the Acquisition Configure form To read the values only but not change them set Left and or Top to 1 when calling the procedure ConfigAcqSize var Width Height integer Use this procedure to read the Width and Height of the Acquisition Configure form ConfigPostProcPosition var Left Top integer This procedure can be used to change or read the Left or Top positions of the PostProcess Configure form To read the values only but not change them set Left and or Top to 1 when calling the procedure ConfigPostProcSize var Width Height integer Use this procedure to read the Width and Height of the PostProcess Configure form ConfigStimPosition var Left Top integer This procedure can be used to change or read the Left or Top positions of the Stimulus Configure form To read the values only but not change them set Left and or Top to 1 when
42. calling the procedure ConfigStimSize var Width Height integer Use this procedure to read the Width and Height of the Stimulus Configure form CreateProcess command string xpos ypos integer THandle This can be used to start another application from a Praxis script The handle of the application s window is returned as the result of the function THandle is an integer value use as a window handle for later accessing the opened application so it can be closed again xpos and ypos are the screen coordinates at which to open the new application s window For examples see the code ProbeCalWizardNoPod pas in the ProbeCal Demo script Also see Calling COM servers from Scripts for other ways to access other applications DataDirectory string read Contains the starting path and directory for saving and loading data files This is the path that is shown as default in the Save Load dialog boxes for px2 data DataFileLoad Plot TDataPlot filename string Loads the data file identified by the path and name in filename into the identified Plot DataFileSave Plot TDataPlot filename string boolean Saves the data contained in the Plot to a file identified by the path and name in filename Returns true if successful DeletePlot var DP TDataPlot Deletes the plot identified by DP You cannot delete the Primary Plot Use this method of Praxis instead of the Free or Destroy methods of the plots using those methods will likely cause
43. ced microphone inputs are to be used simultaneously OutputEnabled index integer boolean Read Write Determines whether the stimulus output is allowed to come from the soundcard THIS VALUE IS NOT SAVED IN PRAXIS CONFIGURATIONS OutputGain channel integer double Read Write Output Gain in dB for each channel OutputPeak Index integer double Read Write Peak value of the last buffer sent to the Output D A This gets cleared on some internal operations Index indicates the channel Writing to it causes praxis to attempt to set the output for the specified output level based on the latest buffer OutputResolution integer Read Write D A sample resolution 16 or 24 Other than in specializes uses use this to also control the A D sample resolution unless the user has first selected separate sound cards or separate sample resolutions for record and play using the menus in the Levels window To assure the state of the system scripts should normally call Praxis UseSingleSoundDevice to assure one soundcard is being used Value must be supported by current hardware 16 must always be supported Only values of 16 or 24 are supported OutputSampleRate integer Read Write D A sample rate Other than in specializes uses use this to also controls the A D sample rate unless the user has first selected separate sound cards or separate sample rates for record and play using the menus in the Levels window To assure the state of the system
44. cutable file praxis exe This will allow the script to appear in the Geet Launcher linkID 61 00 for easy access In most cases the proper home directory for the script subdirectories will be C Program Files Praxis VCLScripts In Demo Mode the script directories should be subdirectories of the directory named DemoScripts which itself resides under the same directory as the Praxis executable file This will allow the script to appear in the Seript_auncher linkID 6100 for easy access In most cases the proper home directory for the script subdirectories will be C Program Files Praxis DemoScripts Ideally each script subdirectory should contain all the following files e Description rtf a rich text file which can be created using the WordPad application which comes with Microsoft Windows This should give a brief description of the script for display in the Script Launcher Picture bmp a bitmap file width 150 pixels height 100 pixels This can be easily created using a an application such as Paint which comes with Microsoft Windows This picture can give a visual hint about the script in the Script Launcher ipr this file is generated using the Liberty Script Editor and identifies the files that make up the script code and visual forms There should be ONLY ONE of these ipr files in a script directory e dfm this contains data about the visual forms It is created by Liberty Script Editor There can be
45. d in Delphi 5 e All variables in Delphi Script are always of Variant type Typecasting is ignored e Types in variables declaration are ignored and can be skipped so these declarations are correct var a integer var b integerr var c d e Types of parameters in procedure function declaration are ignored and can be skipped For example this code is correct function sum a b integer begin result a b end e Type of array elements is ignored and can be skipped so these declarations are equal var x array 1 2 of double var x array 1 2 e These keywords are ignored interface implementation program unit You can use them but they have no effect e in directive in uses is ignored e Delphi Script doesn t support type declarations It tries to skip them but complex declarations may cause parser to fail e and operators are not supported e You can t use the function name to set the return value use Result to do so e Nested routines are supported but you can t use variables of top level function from the nested one e The following keywords are not supported as asm Class dispinterface exports finalization inherited initialization inline interface is library object out property record resourcestring set type e The following directives are not supported note that some of them are obsolete and aren t supported by Delphi too absolute abstract assembler automated cdecl contains defau
46. e Avalue LabJackS InlO 0 DelphiScript Avalue is changed to a 1 if IOO is high otherwise it is changed to 0 Avalue LabJackS InIO 0 VBScript example LabJackS OutVoltage line integer single write This indexed write only property is used to define the analog output DC voltage at one of the screw terminal line AOO when line 0 or AO1 when line 1 These voltages are generated by the LabJack using a 10 bit DAC and the voltages can be configured for between 0 and 5 Volts Example LabJackS OutVoltage 0 2 876 DelphiScript the voltage at line AOO will change to 2 876Volts LabJackS OutVoltage 1 3 210 VBScript example sets AO1 to 3 210 Volts LabJackS InVoltage line integer single read This indexed read only property is used to read the analog DC voltage at one of the eight screw terminal lines AIO Al1 AIZ or to read the differential DC voltage at one of four pairs of screw terminals The voltages are converted using 12 bit ADCs This allows the LabJack to function as a multi input DC voltmeter Single ended analog input operation when the value of line is set in the range 0 to 7 the voltage read will be from Al0 A1 A2 or AI7 respectively and the usable input range is 10V to 10V When the value of line is set in the range 8 to 11 then the voltage read will be the difference between the voltages at the A0 A1 A2 A3 A4 A5 or A6 A7 respectively The voltage of each terminal wi
47. e level for determining relative dB or results in component tracking for each trace field Tone A and B are specified by the StepFField Tone properties O none 1 A 2 B StepFField1THD StepFField2THD boolean Read Write If true Total Harmonic Distortion products will be tracked for the given field trace and reported per tone 1 of the specified output channel StepFDomainOutCh If false the frequency component to be tracked will be as specified by the other StepFField properties StepFField1ToneA StepFField1ToneB StepFField2ToneA StepFField2ToneB integer Read Write These identify which tone will be used from the related StepFField OChan output channel to specify which harmonic or intermodulation mixing product will be tracked See the Component Tracing Configuration Editor for details TimeConstant double Read Write The time constant value used when AverageType is atDecay TimeOfFlightAsynch double Read Write Same as the Propagation Time parameter used for some acquisition types with Async or Chirp stimuli TimeOfFlightSyncFft double Read Write Propagation time used to hold off acquisition of synchronous data when a considerable time delay exists in the measurement path TrigChannel integer Read Write The input channel which is monitored for the triggering level and slope TrigPolarity integer Read Write The polarity of the level at which Triggering will be activated If set to zero triggering
48. e user changes the RealValue by manipulating the visual ERS control e ShowDotSpin this should normally be left false in scripts e ShowuUnits this determines whether the ERS will display the units string in the control H StepMode this determines how the control will change when the up down buttons are clicked or the mouse wheel is rolled The user of the script can also change this setting for each ERS by right clicking the up down part of the control Choices are H sm12345 will change to the next higher or lower value having one significant digit that is 1 2 3 4 or 5 For example increasing from 34 56m Volt will result in a next value of 40m Volt e sm125 will change to the next higher or lower value having one significant digit that is 1 2 or 5 For example increasing from 4 567m Volt will result in a next value of 5m Volt e smFine this setting should not generally be used in scripts e smIntRound values will change only to whole numbers as determined by CardInc Used with InOnly e smLog values will change multiplied or divided by RealMult e smReal values will change incremented or decremented by Reallnc e Units this string value is displayed in the control to help the user understand what is being controlled There are several events associated with each EditRealSpin controls In scripts only these are likely to be useful D OnClick occurs when the user clicks on the control H OnValChange this occurs when t
49. ed WaveletLevelResolution The decibel range tolerance within which a searched for distortion limit value or maximum level can be assumed to be foung WaveletLimitCondition integer Read Write An integer value that determines what kind of measurement result is used to find maximum output level capability with Wavelet Burst Stimuli 0 compression 1 Total HD Harmonic Distortion 2 2 HD 3 3 HD WaveletLimitVal double Read Write The dB limiting value that is used with WaveletLimitCondition WaveletUseWindow boolean Read Write Determines whether PRAXIS will use time domain windowing with microphone input during wavelet acquisition analysis Wavelet Maximum Level Capability or Wavelet Single Frequency Acquisition WaveletWindowMinCycles integer Read Write When WaveletUseWindow is true and the input is from a microphone the later edge of the time domain window will be moved out to accomodate at least this many cycles of the stimulus wavelet test frequency Valid only with wavelet acquisition types Wavelet Maximum Level Capability or Wavelet Single Frequency Acquisition WindowType SyncOrResync boolean TWndKinds Read ONLY The type of data window to be used with Async acquisitions if SyncOrResync False or with Synchronous or ReSynched measurements if True To set the Window type use the SetWindowType procedure see above PostProcess Control Prefix these properties and methods by the indentifier Praxis Ca
50. eeeeeeaaeeeseeaeeeeeeaeeeenenaes 27 Properties and Methods of the Praxis ole 30 EEN EE WEE 30 Data Mari OUlation ET 36 Input Output Control 36 Primary Plot Formatting via the Praxis Obert 38 SUMUIUS GOMtrOl eer cc tesa eects teccevacad caadeccelegs Egide AER an heedtaetenie p Taa aae a adia 39 ACQUISITION E Inte EE 42 POSIPLOCESS ele TEE 46 Handling Secondary Plots in a script 51 Properties and Methods of Plot Objects seseesseesseeneeeiesiesiesiisstinstinstnnsrnnstnnntnnntnnnnnnennnnt 51 About Praxis Scripts This guide is intended to for use with the PRAXIS v2 0 manual in the development of custom scripts which can be run within the PRAXIS measurement system Praxis Scripts are Windows applications in themselves that run from within PRAXIS They include visual forms on which you can place familiar user interface components like buttons edit boxes sliders text editors images etc and easily give them high level functionality by setting properties and writing code in DelphiScript based on Borland Delphi or VBScript a language based on Microsoft Visual Basic The Scripts are developed using the Liberty Script Designer which is an additional separate application that is installed along with PRAXIS and which can be started from within Praxis The Script Designer can be started by using the Scripts gt Design a Script menu on the Main Form Although Praxis was developed entirely using Borland s Delphi
51. entional output tones SpectrumNormalize boolean Read Write If 2 channel RTA or 2 channel FFT is being used for acquisition will cause Channel 1 s data to be normalized with Channel 2 s data during acquisition This corresponds to the Normalize checkbox of the Acquire Configure form SpectrumTotal index integer double Read When used with FFT type acquisitions this property returns the total energy in the Primary plot for the curve indicated by index Property CalcDisplayedFreqsOnly determines whether the entire data curve or just the region currently displayed in the PrimaryPlot is used to calculate the sum This calculation includes the effects of SpectrumHideStimulus that is this can be used to calculate only energy at non stimulus frequencies StepFDomainOutCh integer Read Write Indicates which channel will be used to determine the frequency points using that channel s Tone 1 against which the data will be plotted Valid values are 1 or 2 For Component Tracking Acquisitions with Stepped Frequency Stimuli StepFField1MultA StepFField1MultB StepFField2MultA StepFField2MultB integer Read Write These are the multipliers for the indicated trace field and tone A or B used to specify which harmonic or intermodulation mixing product will be tracked See the Component Tracing Configuration Editor for details StepFField1Ref StepFField2Ref integer Read Write Specifies which tone s level will be used as the referenc
52. equency dB will be used to limit the output stimulus level as a function of frequency Values of OdB or higher will not be limited Used only if WaveletUseMaxLevelFile is true WaveletUseMaxLevelFile boolean Read Write Determines whether the MaxLevelFile will be used to limit output stimulus levels WavFile string Read Write The file name to try to use for a WAV file stimulus Acquisition Control Prefix these properties and methods by the indentifier Praxis AcqSize integer Read Write Sets the size of the Acquisition array which will be acquired for each screen update Depending on other settings this value may be over ridden or adjusted by the system when Acquisition starts This value cannot be set while the acquisition engine is running Acquisition integer Read Write See Global Constants AutoLevelStatus integer Read Indicates whether an attempted AutoLevel adjustment process has completed and the result 1 failed O in process 1 succeeded AvgFrameRate double Read Read this property to find the update rate frames per second for FFT or RTA acquisitions The value will depend on computer speed FFT size sample rate and resolution AutoStartTime TdateTime Read Write This uses the Delphi TDateTime format to specify a time and day at which PRAXIS will automatically begin acquiring as if the Start button were pushed at that time For this to occur the computer must be left on with PRAXIS active after t
53. er 1 to 5 specified by the frequency or time domain value The indicated marker must be enabled If the value is not on an exact data point for the frequency the marker will be moved to the next higher or lower valid frequency Use MarkerNext and MarkerPrev to adjust it to an exact data point MarkerNext Index integer Moves the specified marker to the next valid data point to the right MarkerPrevious Index integer Moves the specified marker to the next valid data point to the left MarkerSearch Max Local boolean Curvelndex Mkrindex Integer This procedure will cause marker number MkrIndex 1 to 5 to search along the visible areas of trace Curvelndex 1 or 2 If Max is true the search will be toward a maximum value otherwise the search will be toward a minimum value If Local is true the search will be only along adjoining points until no further upward slope is encounter If Local is false the marker will go to the highest or lowest displayed data point on the trace MarkerTracking Curve Index integer MkrTrackTypes Read Write Sets or reads the type of tracking for marker Index 1 to 5 tracking on the indicated Curve 0 or 1 Only the last assigned tracking type for this marker will be effective The marker must be enabled see UseMarker below MouseButtonLeft boolean Read Reads true if the last mouse button clicked in the plot s graph was the left mouse button MouseButtonShift integer Read Reads the states
54. erties TimeGainMode integer Read Write Determines how gain will be applied to time domain data for Time Domain Postprocessing operations Time Domain Length Channels or Math A value of 0 specifies that each channel of the Postprocess Target plot will be individually normalized so that its largest magnitude is 1 A value of 1 specifies that both channels are normalized together by the same scale factor so that the largest of either is scaled to a magnitude of 1 used for keeping proportions of binaural files unchanged A value of 2 specifies that the gains are to be adjusted according to the PostProcTimeGainDb1 and the PostProcTimeGainDb1 properties To prevent any change to the levels of the processed Target plot specify TimeGainMode to be 2 with PostProcTimeGainDb1 and PostProcTimeGainDb2 set to OdB TimeLengthAdjustVal double Read Write This value in seconds will be used in Time Domain Length postprocesses when the TimeLengthMode property is set to 1 2 or 3 Extend beginning Extend end or delay TimeLengthMode integer Read Write Determines how the length will be changed in a Time Domain Length positprocess 0 indicates that the Target is to consist of that portion of the Source that is between the window edges of the source 1 means Extend at the beginning 2 means Extend at the end and 3 means delay Settings of 1 2 or 3 will use the value specified in the TimeLengthAdjust property for extension or delay TimeMathM
55. et while the acquisition engine is running FindWinEdges This procedure causes Praxis to try to find the leading and ending edges for removing echoes from acquisitions which work via Impulse Response measurements normally using Chirp and MLS stimuli Has no effect with Async stimulus types impedance measurements or measurements not utilizing an impulse response FindWinEdgesEachAcq boolean Write Use to determine whether Praxis should try to find the leading and ending edges for removing echoes from acquisitions which work via Impulse Response measurements normally using Chirp and MLS stimuli Has no effect with Async stimulus types impedance measurements or measurements not utilizing an impulse response FreeRunAfterTrig boolean Read Write When true acquisition will continue without needing further triggering when triggering is active When false triggering will not occur again until conditions for another trigger event are satisfied HideLineBW integer Read Write The bandwidth value in FFT bins one bin is SampleRate FFTsize that will be hidden in an FFT acquisition for each stimulus tone when the property SpectrumHideStimulus is used IsolateDistortion boolean Read Write H true and if the ReferencelRFile is valid then FFT or Time Domain acquisitions will be split into linear parts and distortion and noise parts This is done by calculating an Expected signal from the stimulus and measured IR of the system be
56. extent of the new data will be points 1 samplerate seconds NumberOfPoints Integer Read Returns the number of points in the domain time or frequency of the data set contained in the plot NumberVerticalDivisions integer Read Write Read Write Sets or reads the Vertical Number of Divisions for the plot Offset double Read Write Accesses the offset value in dB to be used for displaying frequency response or spectrum data Open FileName string This procedure attempts to load and display the data from the compatible file with path name and extension given in FileName PlotDescription String Read Write This accesses the string which is entered in the title tab of the plot s formatting control PlotNowShownFromSet TDataPlot See Plot Sets below PlotScheme integer Read Write This value can be set to 1 if your script will take responsibility for drawing the graph area on the BmpCanvas You shoud not set this to any other value Put the code to redraw the plot in an Event Handler method of the main form in your script named UserRedrawPlot Sender The single argument of the Event Handler Sender is the plot a TDataPlot object which is causing the event and which needs to have its bitmap canvas redrawn Plot Sets A plot set is a grouping of a number of plots so that they occupy the same on screen form They can be manipulated from scripts using the following methods of the Plot object e IsInAPlo
57. f limit curves is needed see function IsWithinLimits DefineLimitPlot IsUpperLimit boolean Source TDataPlot Limitindex integer Declares the data contained in a different plot object Source to be used as the upper if IsUpper is true or lower limit if false for Pass Fail evaluations LimitIndex is normally 1 but can be assigned other values if a set of limit curves is needed see function IsWithinLimits Delay double Read Write Accesses the delay compensation value for removing delay effects from phase data of frequency domain plots The value entered is the amount of delay to be removed DisplayedCurve index integer integer Read Write Select the curves traces to display Index is 1 trace A or 2 trace B Assigning a value of 1 disables display of the curve For frequency domain data the first data field is 1 do not assign a value 0 to either trace 0 is the frequency array For time domain data 0 is the first data field DistortionAsPercent boolean Read Write Sets or reads a value which determines whether normalized distortion product measurements use dB format if false or percent format if true DomainFromPoint point integer double This function returns the frequency or time value at the point indexed by point the first point is 0 EnableMouseClickEvent This procedure allows mouse clicks in the plot form to trigger a MouseClickInPlot event in a running script To disable this again use the Mo
58. ful TSTextFileSave filename string boolean Attempts to save the text report of the T S parameters to the named path and filename Returns true if successful TsUseAddedMass boolean Read Write When true the added mass method will be used for T S parameter estimation of Vas When false the delta compliance or Box Method is used TSvolume double Read Write In Litres Used in delta compliance or Box Method measurement of Theile Small parameters UseFastTSExtract boolean Read Write If true only the traditional method of analyzing the impedance curve finding the peak and the 3dB points will be used This is extremely fast but does not model voice coil inductance If false a full curvefit will be performed WfSteps integer Read Write Maximum number of steps sheets to use for PostProcess Waterfall plot generation WfTimelnc double Read Write Seconds between sheets for PostProcess Waterfall plot generation Handling Secondary Plots in a script To get access to a secondary plot in PRAXIS script the plot should be one that is created within the script otherwise there s no way to get hold of it The type of any plot is TDataPlot Declaration MyNewPlot TDataPlot DelphiScript Dim MyNewPlot as TdataPlot VBScript Creation from a script MyNewPlot Praxis GetNewPlot DelphiScript makes a new plot MyNewPlot Praxis GetNewPlot VBScript Now you can use any of the methods or properties of
59. g LoadMultiPlotList AllMkrOff Sender TObject Set the value Gender to nil or to some object it does not matter This procedure turns off all markers from the plot See the Property UseMarker index for turning each marker on or off individually AutoAll Attempts to both AutoScale and AutoReference all displayed traces in the plot This is equivalent to clicking on the small lighting bolt button at the bottom of the plot AutoRef Index integer Attempts to AutoReference the data curve 1 or 2 indicated by Index AutoScale Index integer Attempts to AutoScale the data curve 1 or 2 indicated by Index AutoScaleRef Index integer Attempts to both AutoScale and AutoReference the data curve 1 or 2 indicated by Index BackColor TColor Read Write Sets or reads the color used to draw the backgrounds of the plots when UseCustomBitmap is false BmpHeight integer Read Returns the height in pixels of the bitmap area of the graph for custom plotting on the BmpCanvas BmpWidth integer Read Returns the width in pixels of the bitmap area of the graph for custom plotting on the BmpCanvas BmpCanvas TCanvas Read Returns a TCanvas object for use in custom plotting of graph areas using Delphi canvas methods or for annotating graph areas drawn by Praxis Custom plotting is best handled by setting PlotScheme to 1 to prevent Praxis from drawing on the canvas other than the background and by putting the code to redraw the
60. g and trailing blanks removed function ToPwr2 x integer integer returns the equal or next LOWER power of two value near x function ToHigherPwr2 x integer integer returns the equal or next HIGHER power of two value near x function ToNeatMult x double r double double returns value nearest x which is a multiple of r r is usually from a 1 2 5 pattern value function VdBToScalar x double double returns 104 x 20 result limited to always above 1E 20 function Within max value min double boolean returns true if value is between max and min max need not be gt min procedure WritePortWord PortAddr Integer Value Word provides DIRECT WRITE ACCESS to hardware ports of the computer Use extreme caution this lets you do things that Windows does not normally allow and can cause trouble if used incorrectly PortAddr is the address of the port be sure to give the decimal not hexadecimal value for the port Also see function LPTout Controlling LabJack hardware The LabJack U12 hereafter called the LabJack in this documentation is a USB connected device that allows software such as a PRAXIS Script to input and output digital or slow analog signals for controlling or monitoring external devices It also provides a low current 5VDC power supply from the USB bus The LabJack can be used for custom test fixtures indicators or DC voltage measurement LabJack U12 devices can be purchased throu
61. g the ScriptsDir function NormalizeWeightNumpoints integer Read Write Sets or reads the number of logarithmically spaced frequency points that will be used when generating Normalize data when the user presses the Normalize button on the Weighting tab sheet of the Plot Forms Path string Returns the Path less filename and extension where the Praxis executable file is stored This can be used to address other files in the same directory or to address subdirectories where data files may be stored PerformPostProcess Activates the PostProcess operation PlotCount integer Read The number of secondary plots currently existing PlotExists DP TDataPlot boolean Returns true if plot DP still exists Postprocess integer Read Write See Global Constants PostProcessCfgVisible boolean Read Write Sets or hides the PostProcess Configure Form PrimaryPlot TDataPlot Read Write Use this to control the Primary Plot s properties and methods when you wish to use its Plot object methods or properties There is also a global function PrimaryPlot which can be used the same way In other words you could use these interchangeably PrimaryPlot HorizontalStart 20 using the function Praxis PrimaryPlot HorizontalStart 20 using the PRAXIS property PrintToFileGo PS TPrintStyles DP TDataPlot Procedure to trigger a Print To File operation user must respond to menu to supply filename ProbeBalance double Read Write
62. generate a series of serial numbers The string will be changed so that any positive numerical characters at the end of the string will be incremented or decremented For example MySN1234 gt MySN1235 procedure InOrder var v1 v2 double swaps V1 V2 if V2 lt V1 function InputGainSettingNeeded InChannel integer VoltsPeakExpected double double returns the dB gain setting that should be used for Praxis InputGain Channel to accommodate an input voltage of VoltsPeakExpected function InputVoltageToClip InChannel integer InPotGain double double returns the input voltage at the given channel and the given input slider setting that would overdrive the input InPotGain is in dB and is lt 0 Use this to determine whether an expected input level is within the linear input range of the system function IsDoing s string boolean see SetDoing below function IsEven i integer boolean returns true if i is an even integer value function IsInDoing s string boolean see SetDoing below function IsPositive Value double boolean true if Value gt 0 function IsWin2kPlus Boolean returns true if the operating system being used is Windows2000 or newer procedure KillLog Call this procedure to clear the data displayed in the debugging log form and to hide that form function linterp x x1 y1 x2 y2 double double linearly interpolates y x given 2 defined values y1 x1 and y2 x2 function
63. gh D7 of the LabJack s digital bus are used only as outputs while bits D8 through D15 of the LabJack s digital bus are used only as inputs In the documentation below the LabJackS object name is included in names of the methods and properties to emphasize the form in which they should be used LabJackS OutByte Integer Write This write only property can be used to write one byte of signals to the lowest order 8 bits bits DO through D7 of the LabJack s digital signals Using this configures all of the lowest 8 digital bits of the LabJack to be logic output signals and sets them to the binary value contained in the lowest 8 bits of the value DO NOT USE THIS PROPERTY UNLESS YOU ARE SURE THAT NONE OF THE BITS DO THROUGH D7 ARE BE BEING EXTERNALLY FORCED TO A FIXED STATE INOTHER WORDS MAKE SURE NONE ARE GROUNDED OR TIED TO A POWER SUPPLY VOLTAGE USE OF 1000 OHM SERIES RESISTORS IS RECOMMENDED Example LabJackS OutByte 63 DelphiScript LabJackS OutByte 63 VBScript LabJackS InByte Integer Read This read only property can be used to read on byte of signals from data input array bits D8 through D15 of the LabJack interface The state of digital line D8 of the LabJack will be indicated in bit 0 of the returned integer line D1 of the LabJack will be indicated in bit 1 of the returned integer etc Bits 8 through 31 of the returned integer will be O Using this property configures all of the second lowest 8 digital bits of the L
64. gh Liberty Instruments Inc or through www LabJack com Further information about the LabJack U12 and other accessories along with a detailed user manual can be found at the LabJack web site The LabJack has 20 digital I O pins four of which are protected against over voltages and overloads and available as screw terminals IO0 IO3 The other 16 digital I O pins DO D15 are available on the D connector These 16 DO D 15 pins are NOT protected against overdrive or overload so you must make sure to e Never drive any of lines DO D15 high from an external source if that pin has not already been configured as in input Configure it as input before it is connected then drive it If this condition cannot be assured you can use series resistors of approximately 10000hms between the lines and the logic input being driven to provide protection provided the driving source remains in the range 0 to 5VDC Use of these resistors is highly recommended e Never drive any of the DO D15 pins beyond the range 0 to 5VDC e Never load any of the DO D15 pins with a load of less than 200 ohms nor draw more than 25mA current from the pins A degree of protection from overload can be obtained if you always connect these lines to external circuitry via series resistors of approximately 1000 ohms e Aninexpensive protection interface model CB25 is also available to provide overdrive and overload protection for lines DO D15 The CB25 can be purchased from L
65. he point related to a graphic pixel position or a floating point domain value For example for the dB magnitude of the point nearest 1kHz in a frequency response plot use v ThisPlot ValueAtPoint ThisPlot PointFromDomain 1000 1 Field O of a frequency domain plot is the frequency value Field 1 is usually the dB magnitude Field 0 of a time domain plot is the data of the first trace the time value is inferred from the point index and the sample rate You can use the UnitsOfMeasure function to find what type of data is stored in a field and the NumberOfPoints property to find how many points are in the data valid points range from 0 to NumberOfPoints 1 and each trace Field contains separate data for each domain point ValueAtX X integer DfieldNum integer double This function returns the raw value in the data field indicated by DfieldNum for the domain value corresponding to position X X is a horizontal coordinate in the BmpCanvas VerticalRefDiv Index integer integer Read Write Sets or reads the VRef division value for the trace 1 A 2 B VerticalReference Index integer double Read Write Sets or reads the Vertical Reference value for the trace 1 A 2 B VerticalScale Index integer double Read Write Sets or reads the Vertical Scale for the trace 1 A 2 B WaterfallAsPeriod boolean Read Write If true waterfall plots will be plotted with the depth dimension shown in number of cycles Q rather than
66. he fill areas of 3D waterfall plots when gradient color is used If this is set to the same value as D3MinColor then gradient color is not used and plotting will then be much faster D3MinColor TColor Read Write Sets or reads the color used for the lowest altitudes in the fill areas of 3D waterfall plots when gradient color is used If this is set to the same value as D3FillColor then gradient color is not used and plotting will then be much faster D3HorizAngle double Read Write Accesses the apparent user horizontal viewing angle relative to the floor in degrees for display of waterfall plots Allowable range is 80 to 80 degrees The graphed structure is always resized for most efficient use of the available display area D3VertAngle double Read Write Accesses the apparent user vertical viewing angle relative to the floor in degrees for display of waterfall plots Allowable range is 0 to 80 degrees The graphed structure is always resized for most efficient use of the available display area so adjusting this parameter may also appear as if it were adjusting the height of the graph DefineLimitFile IsUpperLimit boolean LimFileName string Limitindex integer Declares the data in the px2 format data file indicated by LimFileName full path and filename to be used as the upper if IsUpper is true or lower limit if false for Pass Fail evaluations Limitlndex is normally 1 but can be assigned other values if a set o
67. he horizontal display range time or frequency of the Primary Plot You can also do this using the Plot HorizontalCenter property You should normally set the HorizontalSpan first HorizontalSpan double Read Write Sets the span of the horizontal display range time or frequency of the Primary Plot You can also do this using the Plot HorizontalSpan property HorizontalStart double Read Write Sets the start of the horizontal display range time or frequency for the Primary Plot You can also do this using the Plot HorizontalStart property Must be less than the Horizontal Stop value HorizontalStop double Read Write Sets the end of the horizontal display range time or frequency for the Primary Plot You can also do this using the Plot HorizontalStop property Must be more than the Horizontal Start value Marker Trace Index integer double Read Used to read the marker value on the Primary Plot at the marker s currently placed location Trace can be 1 A or 2 B Index can indicate marker 1 through 5 The indicated marker must be enabled See description of the MarkerFrequency property You can use the general Plot Marker property also MarkerFrequency Index integer double Read Write Used to place or read the position of the indicated marker 1 to 5 specified by the frequency or time domain value The indicated marker must be enabled If the value is not on an exact data point for the frequency the marker will be moved
68. he setting is made and the computer s sleep or hibernate modes must be disabled Also UseAutoStart must be set to True AutoStop boolean Write Set true to make the Acquisition engine automatically stop after a total of Praxis AverageLimit acquisitions have been included in the ongoing average If the system automatically stops in this way an AcqAvgSetDone event will occur AutoStopTime double Read Write The time in seconds after which acquisitions will stop if UseAutoStopTime is true AverageLimit integer Read Write The number of acquired data sets which will be included in the ongoing average result If Praxis AutoStop is true acquisition will stop when this number of averages has been included AverageType TAvgTypes Read Write Type of averaging to use Value must be compatible with Stimulus and Acquisition types AvgReset This Procedure resets the average counter to 0 so the averaging process starts fresh with the next acquisition CalcDisplayedFreqsOnly boolean Used with SpectrumTotal or ShouldCalcTotal properties When true only the energy in the displayed frequency range of the Primary Plot is summed If false all energy in the curve is included FFTsize integer Read Write Sets the size of the FFT which will be used for Acquisitions Should be specified as a power of 2 value Depending on other settings this value may be over ridden or adjusted by the system when Acquisition starts This value cannot be s
69. he user changes the RealValue by manipulating the control It does NOT occur when you change the RealValue in code If you wish to trigger the OnValChange event in code call the ERS control s ValChange procedure MyEditRealSpin RealValue 1 234 MyEditRealSpin ValChange Praxis Specific Methods Functions Procedures and Properties Praxis scripts wouldn t be a very useful feature if they weren t able to control the Praxis measurement and formatting operations To accomplish this there are large number of procedures aka commands methods or Subroutines functions and properties which can be used as if they were part of the programming language There are also certain special objects to which you may need to refer when controlling Praxis from a script One is of course the object Praxis used to control the system Others are Plot Objects of type TDataPlot used to format or access data in various plots In the Properties and Methods sections to follow property names are given followed by their types and their supported uses Read Write or Read Write Function names are followed by their types only Procedure names are defined without a type For example Stimulus integer Read Write is a property EngFloatToStr x double string is a function ShowAcquireCfg Yes boolean is a procedure IMPORTANT None of the these names will be recognized as your Script application is first loading or while its v
70. he value is 2 both symmetries 3 or no symmetry 0 PolarUseNormalize boolean Read Write Indicates whether the Polar Plot should be shown formatted with the largest value in the curve just touching the outside of the polar circle VScale can still be used to adjust the dB division or the number of divisions Print PS TPrintStyles Prints the current data plot to the printer PrintToFile PS TPrintStyles FileName String Prints the current data plot to a graphic file The extension given for the file name determines the type jpg or bmp RestoreLatestData Loads the data from the plot which was used for Praxis s startup data the data which was displayed last time Praxis shut down with the user approving the configuration save or the last data which was in use when SaveLatestData was called from a plot SaveLatestData Saves the data in this plot to be used as Praxis s startup data or for recall using RestoreLatestData SetAutoRef Index integer SetOn boolean Sets AutoReference for the data curve 1 or 2 indicated by Index so that the automatic process attempts to activate continuously i e with every redraw of the plot SetAutoScale Index integer SetOn boolean Sets AutoScale for the data curve 1 or 2 indicated by Index so that the automatic process attempts to activate continuously i e with every redraw of the plot SetLFLimit limit double This procedure sets the low frequency resolution limit of freque
71. hin Praxis You can Handle the following events to respond to certain occurrences happening within Praxis operation To do this you must write an event handler procedure or subroutine The event handler can be a method with the specified name of your main form Event handlers for Events triggered within Praxis always have one single parameter called Sender For example if your main form is called DWform of class TDWform then you might have the following event handler method in your DelphiScript code procedure TDWform InitScript sender Be sure to include this method in your Class type declaration begin If Praxis DemoMode then ShowMessage Welcome Demo Mode user end In VBScript it would look like this Sub TDWform InitScript Sender If Praxis DemoMode then ShowMessage Welcome Demo Mode User End Sub In Version 2 of the Script Designer you can automatically create a script from a template that already has blocks for handling all these events You can follow the sequence of occurance for these events by placing a LogString call in each event handler The Events are listed here under the method names you should use for them in your code e InitScript sender This happens immediately after the script is loaded and displayed This is the event in which to do any settings to the Praxis properties AcqBurst sender This happens after Praxis collects an array of data samples and does basic Ac
72. hrough a set of global functions that essentially expose the DLL functions of the LabJack driver You should use this method only if you need to connect more than one LabJack U12 device to the computer or if you need to configure the digital input and output pins of the LabJack device differently than the way the simpler LabJackS configures them The disadvantage of using these functions is that each function call must typically specify a larger number of parameters making it less intuitive to use for quick programming Use of the LJ_ global functions will also require greater programming skill and some ability to interpret the LabJack s C language based documentation The LJ_ global functions whose names begin with LJ_E are typically simpler to use though not as simple as the LabJackS object properties and are generally preferred unless the most detailed control is required Some of the lower level LJ_ functions require use of array parameter types that have been defined internally within PRAXIS as listed below in the Pascal language t4Integers array 0 3 of Integer tErrorString array 0 49 of Char tVoltages array 0 3 of Single tVBuffer array 0 4095 of tVoltages tlOBuffer array 0 4095 of Integer tCalMatrix array 0 19 of Integer tCalMatrixList array 0 126 of tCalMatrix t127Integers array 0 126 of Integer For detailed description of the LU_ global functions please see the LabJack U12 Use
73. in data curve before doing an Isolate Distortion operation This might be needed for example should anything in the acquisition settings changes The expected curve must be precisely generated using the same settings and conditions as will be used for the measurement in order for the isolation to be able to remove the linear portion of the response SetWindowType SyncOrResynch boolean const Value TWndKinds Sets the type of data window to use with Async acquisitions if SyncOrResync false or with Synchronous or ReSynched measurements ShouldCalcTotal Index integer boolean Read Write Used to determine whether the channel indicated by index 1 or 2 should display its calculated average at the bottom of the Primary Plot for FFT or RTA data Uses CalcDisplayedFreqsOnly property SpectrumHideStimulus Index integer integer Read Write Legal values are 1 1 or 2 Index is the input or FFT channel Causes the display to hide the spectral content near the fixed tones of the indicated stimulus output channel For example Praxis SpectrumHideStimulus 1 2 will cause the FFT display for channel 1 normally Trace A to hide tones that are in the output channel 2 The lines are hidden within the range HideLineBW by showing a flattened level to the spectral data just outside that range The purpose for this is to improve visibility of distortion content during Spectral Contamination measurements by supressing display of int
74. ing measured and subtracting the expected linear signal from the measured signal which consists of the linear result plus distortion and noise components See Isolating Distortion MaxHarmonic integer Read Write The maximum harmonic number 2 to 100 to use in analyzing Total Harmonic Distortion Analyzed harmonics are also constrained to be below samplerate 2 IsTriggered boolean read Indicates whether triggering has occurred valid only if triggering is enabled and acquisition has been enabled via Start ReferencelRFile string Read Write The full path and filename of the Reference Impulse Response file This data MUST be made using a Chirp Synchronous stimulus and and Impulse Resp norm via Chirp acquisition and with precisely the same arrangement of equipment as will be used in the corresponding Isolate Distortion FFT or Time Domain measurement See Isolating Distortion ReferenceResponseFile string Read Write A frequency response file that is used to correct distortion analaysis done with Wavelet Burst stimuli and Wavelet type acquisitions RtaResolution integer Read Write For RTA acquisitions For example a value of 3 would give results in 1 3 octave resolution Min value 1 max value 48 This will also with the FFTSize property affect how low in frequency the measurement can resolve SetExpNeedsUpdate Call this procedure to force PRAXIS to generate a new expected spectrum or time doma
75. isual forms are being first created If you need to initialize any of Praxis s parameters at your script s startup time write an Event Handler method called Initscript for your main script form see for example the procedure TDWform InitScript sender TObject in the WizardModels script and do the initializations there The InitScript event will happen just after the main form is created At that time and thereafter Praxis and its API elements will be known to your script and you will then be able to use them The items documented in these sections contain many methods and properties which are used within Praxis itself Some of these can be used only in very advanced scripts and their usage can be complicated The items documented here are those which we felt could perhaps be helpful in script development but there is no guarantee that all the given methods or properties will be useful General Tips about Script Development Before writing a script to manipulate the data stimulus acquisition system you should try to run through those operations manually This will give you a better idea of the order in which settings and procedure calls should occur For example you should always set the Stimulus property before setting the Acquisition property because the Acquisition property change will not stick Praxis will ignore it unless it is compatible with the currently specified Stimulus In general while the Acquisition engine is ru
76. itmap canvas has been drawn by Praxis It allows you to modify the plot bitmap by adding text lines etc to the bitmap The single argument of the Event Handler Sender is the plot a TDataPlot object which is causing the event and which needs to have its bitmap canvas redrawn Your method should use the Sender parameter to access the BmpCanvas property of that plot and can find its dimensions using BmpHeight and BmpWidth and use Delphi methods to draw your graphics An example of the use of this event can be found at http Awww libinst com praxis_script_writers htm Minimal 20Script AutoLevelDone Sender This event happens when an automatic input level adjustment process has completed with the AudPod Triggered Sender This event happens when the Acquisition is configured to use triggering and the triggering event occurs AutoStoppedByTimer Sender This occurs when an acquisition autostops by using the Timer setting AutoStoppedByAvgLimit Sender This occurs when an acquisition autostops from reaching an Average limit AutoStop Avgs AutoStarted Sender This occurs when PRAXIS automatically starts an acquisition using the Autostart timer AppKeyUp Sender Occurs when the user presses a key while one of the PRAXIS forms has Windows focus MouseClickInPlot Sender Triggered when a mouse is clicked in a Plot This behavior must first be enabled by the plot s EnableMouseClickEvent procedure The value Sender will identify the
77. l cause PRAXIS to check for variable declarations and to stop if any errors are found When writing in VBScript ALWAYS use Option Explicit at the top of each code file Do not use duplicate variable names in different forms For instance don t have a variable X in one form and a different variable X in another Use different names and treat all variables as if they were global Object variables such as MyForm SomeVariable behave as global variables While developing scripts toggle OFF the PRAXIS Backdrop Otherwise when you go to test the code in PRAXIS your Script Designer would be hidden and difficult to access Remember that just because you can see your code and forms in the Script Designer that doesn t mean that PRAXIS can see the latest version of your code be sure to save your file with the changes before trying to run your Script from Praxis PRAXIS and the Script Designer are separate programs and are unaware of what each other are doing Scripts are very powerful And if you ve done much programming then you know that this means you are perfectly capable of crashing Praxis and even the operating system because of bugs or errors in your script For this reason if you have a choice develop your scripts in one of the more stable versions of Windows such as Windows2000 dont even try with WindowsME Know how to close down a frozen process with Ctl Alt Delete e None of the Praxis specific items or
78. lculateSTI boolean Read Write Determines whether Speech Transmission Index will be calculated with other parameters when a Scroeder Curve posiprocess operation is performed You may wish to set this false if it is not needed as the calculation can be quite time consuming CurveFitFreeAir boolean Starts a curve fitting operation to the modeled Impedance data which is in the PostProcess Source plot assumed to be for a woofer measured in free air Returns true if the operation appears to be successful CurveFitMassLoaded boolean Starts a curve fitting operation to the modeled Impedance data which is in the PostProcess Source plot assumed to be for a woofer measured with mass loading see TSMass below Returns true if the operation appears to be successful FilterMagOnly boolean Read Write If true PostProcess filtering options will not affect phase response FilterOrder Integer Read Write For PostProcess Filter operations FilterShape TFilterShapes Read Write Butterworth etc For PostProcess Filter operations FilterType TFilterType Read Write High pass etc For PostProcess Filter operations LF_TruncFixMethod integer Read Write Used in the Quasi Anechoic Bass Restoration postprocess Valid values are 0 and 1 A value of 1 corresponds to selecting the flat method 0 means that option is unselected MathOp TMathOp Read Write For the Math PostProcess PasteOverMode TPasteMode Read Write For the PasteOver PostP
79. leName string This procedure attempts to load the hardware dependent configuration file which is named in FileName To load the Praxis hdi default Configuration file set FileName to an empty string GetNewPlot TDataPlot Creates and displays a new Plot The value returned by this function can be used as an identifier to access the new plot s Properties and Methods Sell also the DeletePlot procedure GroundResistance double Read Write Used in Demo Mode only for correcting impedance measurements KeepFormPositionsAfterScript Call this procedure method to keep the PRAXIS forms from being restored to their before script settings after the script exits By default PRAXIS will attempt to restore the form sizes and positions LevelsFormPosition var Left Top integer This procedure can be used to change or read the Left or Top positions of the Levels form To read the values only but not change them set Left and or Top to 1 when calling the procedure LevelsFormSize var Width Height integer Use this procedure to read the Width and Height of the Levels form LimitFileDirectory string Read Write Used to define where Pass Fail limit evaluation curves are stored or from where they are to be used LineFrequency double Read Write Set this to the power line frequency in your locale It is used to synchronize coherent stimuli so that averaging will tend to reduce the effects of power line interference in measurements LoadPlo
80. les of the line frequency resulting in cancellation of line interference but not of DC offsets UseDcCancel should be set FALSE whenever distortion measurements are being made as even harmonics will also tend to cancel WaveFormSetAdd channel integer WavShape Integer Frequency double Amplitude double Phase double DutyCycle double Adds a new waveform element to the channel 1 or 2 Frequency is specified in Hertz Amplitude as normalized scalar 0 00 to 1 00 phase in radians DutyCycle is 0 to 1 normally 0 5 The new element has a waveshape defined by O sine 1 rectangular 2 step use phase field for delay 3 impulse 4 triangle WaveFormSetClear channel integer Clears all waveforms for the channel 1 or 2 as defined in the Waveform Component Editor WaveFormSetLoad channel integer Filename string Load the set of waveforms to the channel 1 or 2 as defined in the Waveform Component Editor from the path and file named by Filename WaveFormSetPeak channel integer ScaleThem boolean Adjust the amplitudes of all the waveforms in the set for the channel 1 or 2 as defined in the Waveform Component Editor so that the sum is no larger than 1 00 If ScaleThem is true all amplitudes are scaled in their present proportions Otherwise they are all set to the same amplitude WaveFormSetSave channel integer Filename string Save all waveforms for the channel 1 or 2 as defined in the Waveform Component Editor to the path a
81. loginterp x x1 y1 x2 y2 double double interpolates y log x given 2 defined values y1 log x1 and y2 log x2 x x1 and x2 must all be positive nonzero values procedure LogBool b boolean s string Call this procedure to add the value of the boolean b and if given the string s to the messages shown on the debugging log form and to make the form appear if it is not displayed procedure LogDouble d double s string Call this procedure to add the value of the floating point number d and if given the string s to the messages shown on the debugging log form and to make the form appear if it is not displayed procedure LogInt i integer s string Call this procedure to add the value of the integer i and if given the string s to the messages shown on the debugging log form and to make the form appear if it is not displayed procedure LogString s string Call this procedure to add the string s to the messages shown on the debugging log form and to make the form appear if it is not displayed function LPTin LptNumber integer var value byte boolean Provides direct READ ACCESS of an LPT parallel printer port This works only in Windows2000 or WindowsXP and not in all computers Jor more reliable I O use a Labjack device Returns true if successful and the byte value that is read is returned in the variable value See NumberOfLPTPorts function LPTout LptNumber integer value byte boolean
82. lt dispid dynamic export external far implements index message name near nodefault overload override package pascal private protected public published read readonly register reintroduce requires resident safecall stdcall stored virtual write writeonly e These RTL functions aren t supported in Delphi Script Abort Addr Assert Dec FillChar Finalize Hi High Inc Initialize Lo Low New Ptr SetString SizeOf Str UniqueString VarArrayRedim VarArrayRef VarCast VarClear VarCopy e Open array declaration is not supported e CASE can be used for any types So you can write case UserName of Alex John IsAdministrator true Peter IsAdministrator false else raise Unknown user end e Raise can be used without parameters to re raise the last exception You can also use Raise with string parameter to raise the exception with the specified message string For example Raise Format Invalid value d Height e Threadvar keyword is treated as Var e set constructors are not supported You can use MkSet to create a set For example Font Style MkSet fsBold fsltalic e Set operator n is not supported Use InSet to check whether a value is a member of set For example if InSet fsBold Font Style then ShowMessage Bold e Note that set operators lt gt don t work correctly You have to use logical operators For example ASet
83. mChan In other words this can be used for spectral contamination measurements The width of the region ignored around each tone is determined by the value bins which should usually be approximately 5 Also see SpectrumAvgLogF req SpectrumSum fstart fstop double field integer double This function returns the summation of power Result is in volts Pa etc rms over the frequency range between fstart and fstop for the indicated field Data should be spectrum data and field should be 1 or 2 The summation is over equal bandwidths in Hz so that for instance noise in a higher frequency octave would sum to a higher total than would noise in a lower frequency octave SpectrumSumWeighited fstart fstop double field integer double Like the SpectrumSum function but the effect of the weighting curve if in effect is included StartAPlotSet See Plot Sets above StimTonesSum fstart fstop double StimChan integer bins double field integer 1 double This function is like SpectrumNoStimSum except that it gives the power ONLY at the stimulus tones Trace index integer integer Read Reads the Field being currently displayed in the indicated trace 1 A 2 B TraceColor Index Integer TColor Read Write Used to read or set the colors used by the data trace Index 1 is for trace A index 2 is for trace B TraceWidth integer Read Write This property reads or sets the widths of trace lines as drawn in a plot valid range 1 to 5
84. names including Praxis will be recognized while your Script application is loading or while its visual forms are being first created If you need to initialize any of Praxis parameters at your script s startup time do these in the Event Handler method called Initscript for your main script form The InitScript event will happen just after the main form is created At that time Praxis and its functions and identifiers will be known to your script and can be initialized In your script s Initscript event handler use the procedure ScriptConfig see under Global functions and Procedures This will allow you to save the current state of PRAXIS before you script executes load a full configuration file of settings needed by your script and cause PRAXIS to automatically restore its settings after your script exits Be sure to initialize ALL boolean variables before using them For example if you declare a variable ISOK boolean make sure that you set it to an initial value of either true or false in your FormCreate or FormActivate procedure otherwise it may be evaluated as being neither true nor false or may cause other very confusing behavior You are developing an Event Driven program rather than a simple procedural program In other words all script code that gets executed occurs in response to Events of some kind Examples of events are a mouse click a button push a timer going off PRAXIS doing an Acquisition etcetera
85. ncy response data to the specified value Data below this frequency limit will not be displayed Set this to O to allow all data to be displayed to the lowest frequency ShowMultiPlotLegends boolean If Multi curves are displayed this also controls whether their legends the Titles they were saved with will also be displayed ShowPlot This procedure shows the Plot object if it is in a PlotSet or brings it to the front if it is not SpectrumAvgLogFreq fstart fstop double field integer 1 double This function is intended for spectral contamination or Rub Buzz testing when the plot contains an FFT spectrum It returns a result in dB that is equally weighted in each octave over the frequency range from fstart to fstop of the integration of all the power in the range The result is relative that is it should be used only to compare similar situations not to measure absolute power If the Hide tones option for FFT was used the result will ignore the same stimulus tones In that case this function then behaves like SpectrumNoStimSum except that it is octave weighted Use this to evaluate the residual spectrum left by a device as compared to that left by a known good device SpectrumNoStimSum fstart fstop double StimChan integer bins double field integer 1 do uble This is similar to the SpectrumSum function see below except that it ignores tones that are near the frequencies of applied stimulus tones of the output channel Sti
86. ncy and time domain fields which are assigned arbitrary ascending values For advanced use only Always check that DP still exists before using use the PlotExists function of Praxis GetDataPoint DP TDataPlot SField Index integer var Value double boolean This function if the boolean result returns true sets the parameter Value to the Index data point first index is 0 of the field SField from the data set contained in plot DP Field 1 is the frequency or time domain array Field 2 is the first field of the data etc Used to read raw values from the data sets For advanced use only Always check that DP still exists before using use the PlotExists function of Praxis SetDataPoint DP TDataPlot SField Index integer Value double boolean This function if the boolean result returns true sets the Index data point first index is 0 of the field SField from the data set contained in plot DP to the value Value Field 1 is the frequency or time domain array Field 2 is the first field of the data etc Used to read raw values from the data sets For advanced use only Always check that DP still exists before using use the PlotExists function of Praxis Instability may result if invalid values are applied to some plot types Input Output Control Prefix these properties and methods by the indentifier Praxis InputGain channel integer integer Read Write Set the AudPod s input gain setting in dB for each input channel Max 0dB Min
87. nd file named by Filename WaveFormSetToSingleFullTone channel integer Frequency double Sets the channel 1 or 2 to use a Single tone at the specified frequency with amplitude 0 707 WaveletFrequencyStart double Read Write The starting or fixed frequency of a Wavelet burst stimulus WaveletEnvelopeShape integer Read Write Determines the shape applied to the Wavelet Burst stimulus 0 None continuous wave 1 RaisedCosine 2 CosSquared 3 BlackmanHarris 4 Hodie5 5 Hodie7 6 FlatTop WaveletFrequencyStep double Read Write The step in octave fraction used between successive stimulus frequencies when Wavelet Acquisition measurements are made as a function of stimulus frequency WaveletFrequencyStop double Read Write The maximum frequency of a Wavelet burst series of stimuli Used when Wavelet Acquisition measurements are made as a function of stimulus frequency WaveletLength double Read Write The length in cycles of the first tone frequency in a Wavelet Burst stimulus of the shaped tone burst Will be rounded to the nearest number of half cycles WaveletLevelStart double Read Write The starting or fixed level of a Wavelet burst stimulus WaveletLevelStep double Read Write The step in decibels used between successive stimulus levels when Wavelet Acquisition measurements are made as a function of stimulus level WaveletMaxLevelFile string Read Write The file named here in Weight File format ASCII fr
88. nning you should not try to set values which will be used to configure an Acquisition or Stimulus the values on the Config Forms which become grayed out while Praxis is running Set such values such as for example Praxis FftSize before starting or after stopping the acquisition In most cases attempt to change such values while Praxis Running is true will result in the command being ignored In some cases however it is possible that such actions could crash the system For DelphiScript Note that the arguments or parameters if used of procedures or functions are to be enclosed by parentheses while the indexes of properties if used are enclosed by square brackets For example PrimaryPlot TraceColor 1 clRed a property index SomeFrequency PrimaryPlot DomainFromPoint 42 a function argument PrimaryPlot LoadMultiPlotList mylistname a procedure argument Global Constants and Types Constants Stimulus types example usage Praxis Stimulus stiChirp stiChirp 0 Chirp ReSync stiMLSrs 1 MLS ReSync stiMLSPnkRs 2 MLS Pink ReSync stiChirpS 17 Chirp synchronous stilmpulse 3 Impulse synchronous stiMLS 4 MLS synchronous stiMLSPnk 5 MLS Pink synchronous stiSinStdS 6 Fixed Tones synchronous stiSinStd1lA 7 Fixed Tones ch asynch stiSinStd2A 8 Fixed Tones 2ch asynch stiSinSteppeds 9 Stepped Tones synchronous stiSinStepped1A 10
89. nteger demo Integer statelOin Integer updatelO Integer ledOn Integer numChannels Integer channels t4Integers gains t4lntegers var scanRate single disableCal Integer triggerlO Integer triggerState Integer numScans Integer timeout Integer var voltages tVoltages var statelOout Integer var overVoltage Integer transferMode Integer Integer function LJ_AlStreamStart var idnum Integer demo Integer statelOin Integer updatelO Integer ledOn Integer numChannels Integer channels t4Integers gains t4lntegers var scanRate Single disableCal Integer reserved Integer reserved2 Integer Integer function LJ_AlStreamRead locallD Integer numScans Integer timeout Integer var voltages tVBuffer var statelOout tlOBuffer var reserved Integer var ljScanBacklog Integer var overVoltage Integer Integer function LJ_AlStreamClear locallD Integer Integer function LJ_AOUpdate var idnum integer demo Integer trisD Integer trisIO Integer var stateD Integer var statelO Integer updateDigital Integer resetCounter Integer var count LongWord analogOut0 Single analogOut1 Single Integer function LJ_BitsToVolts chnum Integer chgain Integer bits Integer volts Single Integer function LJ_VoltsToBits chnum Integer chgain Integer volts Single var bits Integer Integer function LJ_Counter var pl_idnum integer demo Integer var stateD Integer var statelO Integer resetCo
90. ode integer Read Write Determines the math operation that will occur when a Time Domain Math operation is performed 0 means Copy from Source 1 means Invert from Source 2 means Target Source 3 means Target Source 4 means Convolve Source Target and 5 means Deconvolve Target via the Source as reference Gain will be adjusted per the TimeGainMode property TSanimate boolean Read Write Determines whether Thiele Small curve fitting operations will be animated TSClearCurveFits Clears any existing Thiele Small curve fitting data from the system Used to start fresh for measuring a new driver TSCsvFileSave boolean Attempts to save the set of T S parameters in a comma separated variable format readable by spreadsheets to a file name by TSname Returns true if successful TSdia double Read Write The effective diameter of the woofer in Thiele Small extractions Value is specified in units of meters TSExtract boolean Extracts the Thiele Small parameters from the results of the free air curve fit and the mass loaded curve fit operations Returns true if successful TSmass double Read Write The added mass value used in Thiele Small extractions Value is specified in units of grams TSname string Read Write The name identifying the woofer in a Thiele Small measurement Used for printing reports or saving data files TSPrint boolean Prints a report of the T S parameters to the printer Returns true if success
91. operties that you can configure e Enabled detemines whether the user can adjust the ERS control e AvoidSetFocus this should be left False unchecked for script use e Cardinc how much the RealValue will be incremented decrmented on up down clicks or mouse wheel rolls when IntOnly is True and StepMode is set to smIntRound e EngUnits if true checked quantities will be shown using engineering notation For example the number 1234 5 would display as 1 2345k Engineering units can also be entered by the user into the control e IntOnly if true the RealValue can only be set to whole number values integers e MaxValue the largest number that the control will accept as the RealValue e MinValue the smallest number that the control will accept as the RealValue e Reallnc how much the RealValue will be incremented decrmented on up down clicks or mouse wheel rolls when IntOnly is false and StepMode is set to smReal e RealMult how much the RealValue will be multiplied divided by on up down clicks or mouse wheel rolls when IntOnly is false and StepMode is set to smLog e RealValue this most used property is used to set or read the numerical quantity that is being represented by the control It is a floating point value so if IntOnly is true you should always round the value of RealValue before using it as an integer quantity When you set the RealValue from code the OnValChange event does not occur that only happens when th
92. plot in an Event Handler method of the main form in your script named UserRedrawPlot The single argument of the Event Handler the Sender is the plot a TDataPlot object which is causing the event and which needs to be redrawn CalcTHD FO double var FOLevel double trace integer double This function returns the total harmonic distortion value in percent calculated using the current spectrum data assuming that the plot contains spectral lines for the fundamental and its harmonics obtained from measurement of a single tone stimulus The fundamental frequency is FO and the level at FO is returned in variable FOLevel ClearMultiPlotFiles This procedure removes any Multi traces from the plot CustomBitmapName String Read Write The complete path file name and extension of the bitmap file used for plot backgrounds when UseCustomBitmap is true If an invalid filename is given or if an empty string is assigned then the default Liberty Instruments embossed logo bitmap is used CustomBitmapStretched Boolean Read Write Controls the way plot background bitmaps are drawn when UseCustomBitmap is true If true the bitmap is stretched to cover the background If false multiple copies of the bitmap are used to tile the background D3BaseColor TColor Read Write Sets or reads the color used for the base or floor of 3D waterfall plots D3FillColor TColor Read Write Sets or reads the color used for the highest altitudes in t
93. properties of the Praxis object You can then use the Praxis FormStates property to restore the Praxis system when the script ends to the visiblities the user had when the script started Enumerated Types Use one of the names given in parthesis when a property or method requires a value from these types dvType dvTime dvFreq used with DomainView button of Praxis MkrTrackTypes mttNone mttLMax mttLMin mttVMax mttVMin used for MarkerTracking property of Plots LMax is local maximum VMin is visible minimum etc TAvgTypes atLog atMag atRMS atCoh atDecay used for AverageType property of Praxis TFilterShapes fsBrickWall fsButterworth fsCheb01 fsChebl fsBessel used in praxis properties for PostProcessing such as SmoothingFilter TFilterType ftLPF ftHPF ftBPF ftBRF ftAP ft0OdB used in FilterType property of Praxis TInputSelect inProbel inProbe2 inMicl inMic2 inOutl inOut2 inLinexX used for InputSelect property of Praxis TMathOp moSum moDiff moMult moDiv moMax moMin moMagInv moPhaselInv for Math PostProcess TPasteMode pmAbove pmBelow pmClearTarget pmAl11 for PasteOver PostProcess TPrintStyles psBW psColorLines psColorFill used with Print method of Plots TRemapFormat rfifftCompat rfLogSpace rfFreqList rfFromSource for Remapping PostProcess TWndKinds wnNone wnRect wnBH wnBHh wnH wnHh wnH7
94. quisition processing For example in a Stepped Frequency measurement this happens after data is collected for each applied frequency step AcquiredOnce sender This happens every time an Acquisition process has completed If a number of them are being averaged it happens on each averaged event AcqAvgSetDone sender This happens if the AutoStop property is true when the entire specified number of averages have been included in the acquisition data AcqStarted sender This happens when a Praxis data acquisition is started AcqStopped sender This happens when a Praxis data acquisition has stopped BeforeAcgPlot sender This happens just before newly acquired data is about to be plotted to the Primary Plot AfterAcqPlot Sender This happens just after newly acquired data is plotted to the Primary Plot UserRedrawPlot Sender This happens when a plot has its PlotScheme property set to 1 and its bitmap canvas needs to be redrawn It is intended so advanced scripts can draw their own graphics in the resizable plot s graphing area The single argument of the Event Handler Sender is the plot a TDataPlot object which is causing the event and which needs to have its bitmap canvas redrawn Your method should use the Sender parameter to access the BmpCanvas property of that plot and can find its dimensions using BmpHeight and BmpWidth and use Delphi methods to draw your graphics UserAnnotatePlot Sender This event is called when a plot s b
95. r s Guide For use within PRAXIS the function names are changed slightly from those given in the guide in that each function name is augmented with the prefix LJ_ For example the PRAXIS function LJ_EDigitalOut will be documented in the LabJack U12 User s Guide as EDigitalOut This is done to avoid confusion with other similarly named functions that may be used in PRAXIS scripts The available LI global functions available from PRAXIS are listed below function LJ_EDigitalOut var idnum integer demo integer channel integer writeD integer state integer integer DO NOT MIX THIS FUNCTION WITH LABJACKS OBJECT USAGE function LJ_EDigitalln var idnum integer demo integer channel integer writeD integer var state integer integer DO NOT MIX THIS FUNCTION WITH LABJACKS OBJECT USAGE function LJ_EAnalogIn var idnum integer demo integer channel integer gain integer var overvoltage integer var voltage single integer function LJ_EAnalogOut var idnum integer demo integer analogOut0 single analogOut1 single integer function LJ_ECount var idnum integer demo integer resetCounter integer var count double var ms double integer function LJ_AlSample var idnum Integer demo Integer statelO Integer updatelO Integer ledOn Integer numChannels Integer channels t4Integers gains t4Integers disableCal Integer var overVoltage Integer var voltages tVoltages Integer function LJ_AlBurst var idnum I
96. r includes a number of enhancements to simply the creation or editing of scripts and to make the scripts more powerful A larger number of visual components are available for use in design including the EditRealSpin also known as a NVC or Numeric Value Control that is used throughout the PRAXIS system Controls avaialable from the Script Designer are VCL controls controls made by and for Borland Delphi and specific documentation for most of these can be obtained if needed by downloading the help file D5VCL_P ZIP from Borland at http info borland com techpubs delphi v5 updates pro html Scripts for PRAXIS can be written in a number of scripting languages However the Script Designer provides specific support such as automatic generation of skeletal scripts only for the VBScript and DelphiScript languages You can also find a basic script writing tutorial on the Download page of our web site Script Design Some Tips and Noteworthy Comments DelphiScript and VBScript while being in many ways very similar to the Delphi and VisualBasic languages are not exactly the same as their superset languages There are some special circumstances that may need consideration Also the nature of designing one program your script to run within another PRAXIS requires some special treatment Please note the items below before starting your custom script design and refer back here if you should run into anything unexpected
97. ript It can be used to access other files in the same script directory for example RichEditl Lines LoadFromFile Praxis ScriptPath Welcome rtf ScriptVariable Index integer variant Read Write Index can be in range 0 32 All variables created or declared within a script become invalid after the script ends or if it calls a new script These ScriptVariables however will be available during the entire Praxis session and can be used to save values between calls of scripts so scripts can record values from past calls or pass values with other scripts that run before or after ScriptVariables are Pascal variant types and can contain data of various other types including dynamic arrays The ScriptVariables are initialized to Null when Praxis starts SelectedPlayDevice string returns the text name of the currently selected soundcard playback device SelectedRecDevice string returns the text name of the currently selected soundcard recording device ShowAcquireCfg Yes boolean Shows or hides the Acquisition Configure form ShowLevelsCfg Yes boolean Shows or hides the Levels Configure form ShowPositProcCfg Yes boolean Shows or hides the PostProcess Configure form ShowPrimaryPlot Yes boolean Shows or hides the Primary Plot ShowStimulusCfg Yes boolean Shows or hides the Stimulus Configure form SpeedOfSound double Read Write In meters second nominally 344 Used in some processing calculations Start Sta
98. rocess PerformPostProcess Activates the PostProcess operation PolarAngle double Read Write In Polar Compilation defines the angle at which the curve data is to indexed when included into the Polar data or the angle for which a curve is to be removed PolarDolnclude boolean Read Write In Polar Compilation defines whether the curve in the PostProcess Source is to be included or removed when PerformPostProcess is called Postprocess integer Read Write See Global Constants PostProcessCfgVisible boolean Read Write Sets or hides the PostProcess Configure Form PostProcDelay double Read Write Delay removed in seconds in certain PostProcess operations PostProcDivAfterFft boolean Read Write If true and if time domain data being subjected to a postprocess FFT operation is dual channel this will cause the two spectra to be complex divided yielding relative spectrum magnitude and relative phase information PostProcFreq1 double Read Write If one frequency parameter is adjustable for PostProcess operation use this value If two frequency parameters are adjustable this is start frequency corner frequency or bandwidth PostProcFreq2 double Read Write If two PostProcess frequency parameters are adjustable this is stop frequency or center frequency PostProcFftSize integer Read Write The size to use in FFTs for certain PostProcess operations PostProcGain double Read Write Gain in dB applied to
99. rt other Windows programs from within your script The arguments to the function are not easily explained see Windows programming documentation if detail is needed but can be illustrated well enough for many uses using some Delphi examples ShellExecute Handle open MSpaint nil nil SW_SHOW lopen a specific file with a specific applet Sc Praxis ScriptPath Picture omp ShellExecute Handle open MSpaint s nil SW_SHOW ShellExecute Handle open Wordpad nil nil SW_SHOW ShellExecute Handle open sndvol32 nil nil SW_SHOW To Open a registered filetype from its registered application si Praxis ScriptPath Description rtf ShellExecute Handle open s nil nil SW_SHOW wordpad word or This can even open a file into PRAXIS sis Praxis ScriptPath planar px2 px2 is registered to PRAXIS ShellExecute Handle open s nil nil SW_SHOW function ShortenFilePath p string string strips off the path stuff if it is under the directory in which Praxis is stored For example C Program Files Praxis SomeDir Whatsit xyz would become SomeDir Whatsit xyz So filenames are portable within scripts function SignOf Value double double If value is positive or 0 1 else 1 function StripLeadingBlanks s string string returns s with any leading blanks removed function StripOutsideBlanks s string string returns s with both leadin
100. rts the Praxis Stimulus Acquisition engine for measurements Stimulus integer Read Write See Global Constants Stop Stops the Praxis Stimulus Acquisition engine for measurements The engine may also stop if an error occurs or if AutoStop is enabled SupportsPlay SampRate SampRes integer boolean checks for claimed playback support from the current soundcard for the given sample rate and resolution SupportsRecord SampRate SampRes integer boolean checks for claimed recording support from the current soundcard for the given sample rate and resolution TimeWindowBegin double Read Write Accesses the setting in units of seconds of the Time windowing starting edge This is used for windowing out regions of time domain data before transformation to frequency domain The time domain data must be from a Synchronous or ReSync measurement TimeWindowEnd double Read Write Accesses the setting in units of seconds of the Time windowing ending edge This is used for windowing out regions of time domain data before transformation to frequency domain The time domain data must be from a Synchronous or ReSync measurement UnitsMetric boolean Read Write True if users s Preference Units selection is for metric units rather than American English units UsesBackdrop boolean Read Write Use this to determine whether a backdrop is used behind the PRAXIS forms UseSingleSoundDevice sets the system to use the same record device a
101. s is currently being used for the play device and the record sample rate and resolution to equal the play sample rate and resolution These are the normal settings for Praxis operation and should be used in all scripts UseFlexWindow boolean Read Write shows or controls whether new FFT operations will use the FlexWindow to allow for gradual transitions from windowed to unwindowed operations UseDashed Boolean Read Write Same function as the Dashed Gridlines menu item in the MainForm Controls whether plots use solid or dashed gridlines ValueHold index integer variant Read Write A storage array which can be used by Scripts to save values or to communicate with other scripts that will run later Data Manipulation Prefix these properties and methods by the indentifier Praxis ChangeDataSampleRate DP TDataPlot Value integer This procedure changes the effective sample rate of the data in DP The data in other fields is not adjusted or changed only the values of the time parameters if the data is in the Time Domain For advanced use only Always check that DP still exists before using use the PlotExists function of Praxis ChangeNumberOfDataPoints DP TDataPlot NewNumPoints integer boolean This function if the boolean result returns true changes the number of data points in the data set which is contained in plot object DP If the number is increased from its previous value added values are assigned 0 except for the freque
102. s is heavily biased toward Delphi If you are not experienced in Delphi programming don t be intimidated It is as easy to use as other visual languages easier if you tend to think logically It is an event based language very structured and object oriented There are a number of good books about Delphi Some programmers have even learned it by simply diving into it with use of Delphi s Help files These help files can be obtained from Borland at http info borland com techpubs delphi v5 updates pro html The files DS5VCL_P ZIP and D5OPLR ZIP files are particularly useful Note that there are some differences between DelphiScript and Delphi s Object Pascal Most of these are detailed in the section of that name Although you could conceivably develop your script using Delphi itself note that only the controls shown in the Script Designer will work in Praxis others will prevent the script from running And of course Delphi will not understand the Praxis Specific procedures properties etc so you could not compile or test in that environment Differences between DelphiScript and Object Pascal The following information is provided by Dream Company creators of the Dream Scripter component used in Praxis s Script operations and is reproduced here by permission It is provided as is some portions may not be relevant to use within Praxis This document describes the difference between Delphi Script and Object Pascal use
103. tFormat Plot TDataPlot filename string Formats the specified Plot using the Plot format file named in filename If no path information is given the path of the current script is used Plot format files with suffix pf_ allow one set of data to use the formatting saved previously from a similar data plot LoadPlotPreFormat filename string Pre formats the PrimaryPlot using the Plot format file named in filename If no path information is given the path of the current script is used Plot format files with suffix pf_ allow one set of data to use the formatting saved previously from a similar data plot A Pre format operation saves the formatting information and applies it on the next data acquisition MainForm TForm read Use this property to access the Left Top Height and Width properties of the Main Form Example TopPosition Praxis MainForm Top MakeLimitCurve DP TDataPlot Index RefField integer lsUpper boolean minfreq maxfreq double octaveRes double This is used to generate a data file named UPPERLIMIT PX2 if IsUpper True or LOWERLIMIT PX2 if IsUpper False is replaced by the characters corresponding to Index The file will be saved into the Praxis LimitFileDirectory see above RefField determines the data field in the Plot that is to be used field 0 is normally the frequency 1 is normally the magnitude 2 the phase The values minfreq and maxfreq determine the frequency range that
104. tSet boolean True if this Plot is part of a PlotSet IsInSamePlotSet DP TDataPlot boolean True if this Plot is in the same plot set with plot DP StartAPlotSet This procedure makes this Plot into a PlotSet if it is not already part of one AddAPlotToPlotSet DP TDataPlot This procedure adds the plot DP to the same PlotSet as this Plot object is in IsolateFromPlotSet This procedure removes this Plot from any plot set it may be in After this IsInAPlotSet will return false PlotNowShownFromSet TDataPlot This function retuns the Plot that is now showing in the PlotSet that contains the Plot object from which the method is called ShowPlot This procedure shows the Plot object if it is in a PlotSet or brings it to the front if it is not PointFromDomain domain double integer This function returns the index in the data field arrays corresponding to the given domain value in Hz or sec PointFromX x integer DfieldNum integer integer returns the index into the field arrays for which the domain value exists at horizontal coordinate X in the BmpCanvas The DfieldNum parameter is not used and can be set to 0 Polar Frequency USE property Freq3D for this PolarlsFilled boolean Read Write Indicates whether the Polar plot is to be shown filled or only as an outline PolarSymmetry integer Read Write Indicates whether the Polar plotting process should assume Right Left symmetry if the value is 1 Front Back symmetry if t
105. te Center frequency for filtered PostProcess Schroeder curve SchroederFilterOrder integer Read Write Filter order for PostProcess Schroeder curve SchroederOctBandwidth double Read Write Bandwidth used around SchroederFilterCenter in PostProcess Schroeder Curve Set to 0 for full band SchroederRoomName string Read Write For PostProcess Schroeder curve SmoothingFilter TFilterShapes Read Write Filter type for PostProcess Smoothing SmoothingFilterOrder integer Read Write Filter order for PostProcess Smoothing SmoothIncPhase boolean Read Write Determines if Phase is also included during PostProcess Smoothing SmoothingOctBandwidth double Read Write Octave bandwidth for PostProcess Smoothing SmoothingOctLimit double Read Write Octave band limit for PostProcess Smoothing SpecifiedRe double Read Write If set to 0 Praxis will attempt to approximate the DC resistance of the measured woofer Otherwise it will assume during Thiele Small parameter extraction that the DC resistance is this value StepTrim double Read Write The value to use for adjusting offset in Step Response PostProcess operations TailCorrAutoLowerSlope This procedure automatically sets the TailCorrLowerSlope from the shape of the data near TailCorrLowerFreq TailCorrAutoUpperSlope This procedure automatically sets the TailCorrLowerSlope from the shape of the data near TailCorrLowerFreq TailCorrLowerFreq double Read Write
106. teger FreqStart FreqStop LevStart _LevStop double FreqMode LevMode Integer This procedure changes the last added or only remaining tone in the Stepped Tone specification for the Channel 1 or 2 For FreqMode and LevMode the constants swmLog Of swmLin canbe used ChirpStopFreq double Read Write The stop frequency when Chirp Stimulus is used for impedance measurements otherwise chirp measurements are always full band ChirpTimeLength double Read Write length in seconds of a Chirp Stimulus CompensateForResp boolean Read Write If true the acqgFRandHD or acqFRandIMD acquisition types used with Chirp Stimulus will adjust measured harmonic or intermodulation distortion levels for the effect of the simultaneously measured frequency response of the measurement DenormalizeDist boolean Read Write If true the acqFRandHD or acqFRandIMD acquisition types used with Chirp Stimulus will NOT show the distortion levels in decibels relative to the fundamental frequency response values and will instead show values of the product levels EnvelopeLength integer Read Write The length in samples of the envelope to be applied to certain output stimuli Outside this envelope the stimuli will be 0 no output EnvelopeType integer Read Write The type of envelope to be applied to certain output stimuli 1 rasied cosine 2 cosine squared 3 custom 0 None FreqOfOutTone OutChan Tonelndex integer double Returns the Stepped Tone
107. th MLS or MLSPink type stimuli Legal range 4096 to 524288 SetToOneStepFSpecification Channel integer This procedure deletes all but the first tone of a stepped tone specification for the indicated channel 1 or 2 Use this as the start of a new definition of a stepped tone specification followed by use of ChangeStepFSpecification and AddStepF Specification StepFParameterFile string Write List File name to be used with Stepped Frequency stimulus Setting this value causes the Stepped Frequencies to be determined by list file This merely names the file it does not load it nor check it for existence or correctness StepsinStepFSpecification integer Write Number of steps to be used with Stepped Frequency stimulus Setting this value causes the Stepped Frequencies to be determined by specification Min 2 max 1000 Stimulus integer Read Write See Global Constants UseDcCancel boolean Read Write When true and when used in acquisitions which can be coherently averaged this will cause alternate acquisitions to occur in inverse polarity synchronized to whole cycles of the power line frequency The data obtained in the acquistion will be also inverted When coherently averaged this results in DC offsets in the measuring system soundcard and power line interference signals cancelling over time When false the inversion process is not used on alternate stimuli but the bursts are synchronized to an odd number of half cyc
108. th respect to ground must be within 10V to 10V but the usable voltage difference between the terminals depends on the AnalogGain property setting LabJackS AnalogGain When using LabJackS InVoltage in differential mode the LabJackS AnalogGain property for the desired pair of pins should configured before reading the voltage The usable voltage differences are as given in the following table LabJackS AnalogGain Range 1 20 volts 2 10 volts 4 5 volts 5 4 volts 8 2 5 volts 10 2 volts 16 1 25 volts 20 1 volts Example DelphiScript LabJackS AnalogGain 10 4 Avoltage LabJackS InVoltage 1 0 Avoltage is set to the difference between terminals Al4 and AIS H 5V to 5V Avoltage LabJackS InVoltage 4 Avoltage is set to the voltage at Al4 10V to 10V VBScript LabJackS AnalogGain 10 4 Avoltage LabJackS InVoltage 10 Avoltage is set to the difference between terminals Al4 and Al5 5V to 5V Avoltage LabJackS nVoltage 4 Avoltage is set to the voltage at Al4 10V to 10V LabJackS AnalogGain line integer integer read write This indexed property is used to read or to define the analog gain that will be applied when using the LabJackS nVoltage to read differential voltages from pairs of Al input terminals Values of the index line must be in the range 8 to 11 to match the index of the corresponding index used with InVoltage for differential input This property has no effect
109. to the next higher or lower valid frequency Use MarkerNext and MarkerPrev to adjust it to an exact data point MarkerNext Index integer Moves the specified marker to the next valid data point to the right MarkerPrevious Index integer Moves the specified marker to the next valid data point to the left MarkerSearch Max Local boolean Curvelndex MkrIndex Integer Will cause marker number MkrIndex 1 to 5 to search along the visible areas of trace Curvelndex 1 or 2 If Max is true the search will be toward a maximum value otherwise the search will be toward a minimum value If Local is true the search will be only along adjoining points until no further upward slope is encounter If Local is false the marker will go to the highest or lowest displayed data point on the trace Stimulus Control Prefix these properties and methods by the indentifier Praxis AddStepFSpecification Channel integer FreqStart FreqStop LevStart _LevStop double FreqMode LevMode Integer This procedure adds a new tone to the Stepped Tone specification for the Channel 1 or 2 For FreqMode and LevMode the constants swmLog or swmLin can be used ChirpLinearSweep boolean Read Write True if chirp will use a Linear Sweep False if it uses Log Sweep ChirpStartFreq double Read Write The start frequency when Chirp Stimulus is used for impedance measurements otherwise chirp measurements are always full band ChangeStepFSpecificatio Channel in
110. ts to use the file indicated by ListName complete path and filename with extension lil as a list of data files for Multi display If successful the file names listed are appended to any other file names already being used for Multi display To first clear the list use ClearMultiPlotFiles LoadWeightFile filname string This procedure attempts to use the file indicate by filname including path filename and extension of wgt As a weight file for the plot Marker Trace Index integer double Read Used to read the marker value on the Plot at the marker s currently placed location Trace can be 1 A or 2 B Index can indicate marker 1 through 5 The indicated marker must be enabled See description of the MarkerFrequency property MarkersColor TColor Read Write Use this to set the colors to be used by Praxis triangular data markers for this plot If the value is assigned the value clBlack then the markers will use the same color as the data traces MarkerDelta integer Read Write Sets or reads the marker which is to be used as the delta reference all other markers will list their range values in relation to this marker The designated marker must be enabled see UseMarker below and its range values will list as 0 If the assigned value is outside the range 1 to 5 all markers will list normally MarkerFrequency Index integer double Read Write Used to place or read the position of the indicated mark
111. unter Integer EnableStb integer var count LongWord Integer function LJ_DigitallO var pl_idnum integer demo Integer var trisD Integer trislO Integer var stateD Integer var statelO Integer updateDigital Integer var outputD Integer Integer DO NOT MIX THIS FUNCTION WITH LABJACKS OBJECT USAGE function LJ_GetDriverVersion Single procedure LJ_GetErrorString errorcode Integer var errorString tErrorString function LJ_GetFirmwareVersion var idnum Integer Single function LJ_ListAll var pl_productIDList Integer var serialnumList t127Integers var locallDList t127Integers var powerList t127Integers var calMatrixList tCalMatrixList var numberFound Integer var fecddMaxSize Integer var hvcMaxSize Integer Integer function LJ_LocallD var idnum Integer locallD Integer Integer function LJ_ReEnum var idnum Integer Integer function LJ_Reset var idnum Integer Integer function LJ_Watchdog var idnum Integer demo Integer active Integer timeout Integer reset Integer activeDO Integer activeD1 Integer activeD8 Integer stateDO Integer stateD1 Integer stateD8 Integer Integer function LJ_ReadMem var idnum Integer address Integer var data3 Integer var data2 Integer var data1 Integer var data0 Integer Integer function LU_WriteMem var idnum Integer unlocked Integer address Integer Integer data2 Integer data1 Integer data0 Integer Integer Events Triggered Wit
112. useNormal procedure of this Plot object FindNextDomainPoint domain double IsUp boolean double Domain is the time or frequency value of a data point in the plot If IsUp is true this function returns the next higher data point at which data is stored If IsUp is false this function returns the next lowr data point at which data is stored For example to find the next stored data point above 1kHz that is used in the plot use x FindNextDomainPoint 1000 true FormTop FormHeight FormLeft and FormWidth See Setting Position at the top of this section Freq3D double Read Write The frequency at which Polar Plots are displayed as shown in the Polar Format Tab FreshRedraw This procedure immediately redraws the current data plot GetDataStats var DS DataStats This procedure returns parameters of the data that is currently contained within the Plot The DataStats record is documented at the beginning of this section Example Var DS DataStats GetDataStats DS PointsInTheData DS NumberOfPoints GridColor TColor Read Write Sets or reads the color used to draw the grid lines on the plot HasSameFreqPoints DP TDataPlot boolean This function returns true if the frequency data points of the plot object uses the exact same frequency points as does the plot DP If true the data at each point in the two plots can be related otherwise one plot must first be mapped by a Postprocess operation HoldThisData This
113. will be mapped to make the data and octaveRes is the frequency resolution in octaves for the new data The file is intended for use in quality control Pass Fail testing MiciFileName string Read Write The file name of the correction data file for the Mic1 input to the AudPod The entire path and file name should be used Writing this causes Praxis to attempt to load the file Mic2FileName string Read Write The file name of the correction data file for the Mic2 input to the AudPod The entire path and file name should be used Writing this causes Praxis to attempt to load the file Mic1UsesProbe boolean Read Write If this is true and when an Audpod is used Praxis will obtain Mic1 microphone input signals from the Probe1 jack rather than the tip connection of the Mic jack This avoids the extra preamplification and bias voltage that is used at the microphone jack allows for approximately 12dB greater signal headroom and allows use of balanced microphone inputs The calibration data for Mic1 still is applied NextScriptToRun string Read Write Set this to a full name of the desired Script Directory to load and start up a different script from within your script Will not work if the Acquisition engine is Running collecting data And it will be cleared every time the Acquisition engine stops running so set the value only with then Praxis is not collecting data You can find the current base directory for Praxis Scripts usin