Home

PSU-1000ATX-12N User`s Manual PSU-1000ATX-12N

image

Contents

1. The power supply will overheat and may become permanently damaged it operated without proper cooling A special colorless non electrically conductive internal coolant is used inside the PSU 1000ATX 12N This liquid does not leave the power supply External coolant is supplied through the unit s rear external nozzles Coolant supplied to these nozzles CAUTION The PSU 1000ATX 12N power supply is not a self dissipating product and must be connected to an existing liquid cooling system not included The power supply wil overheat and may become permanently damaged if operated without proper cooling Preparation for Installation CAUTION The PSU 1000ATX 12N must AA Serie oe d e SORREET orientations illustrated below Other directions will not allow the pump to circulate coolant properly or coolant will not fully submerge internal heat sources S Me LHe INCORRECT Direction CORRECT Direction If your chassis has a rear PSU mounting plate this may need slight modification to allow the PSU 1000ATX 12N rear heal exchanger to fit properly Koolance systems which are physically compatible with the PSU 1000ATX 12N include the PC3 700 series except PC3 720 PC4 1000 series except PC4 1020 and PC5 1300 series All of these chassis require removal of a hard drive bay and minor modification to the rear PSU mounting plate or the purchase of a separate Koolance Chassis PSU Mounting Plate if compatible ILPSU Plate
2. Your Koolance PSU 1000ATX 12N power supply may arrive with rubber inserts to protect the top nozzle connections during shipping These should be removed before inserting your desired nozzles Protective Nozzle Inserts Remove 227 DY Wi D DO NOT ATTEMPT TO OPEN THE BOTTOM NOZZLE SOCKETS Doing so will release the internal coolant and void the product warranty DCindcsorlght AC Power Swich If shutting down the power supply using the rear illuminated power switch it may become necessary to reset the unit before it can be powered up again To do this tum the AC power een switch to the Ott position Then unplug the main AC power cable from the PSU 1000ATX 12N Wait approximately 20 30 seconds until the green DC indicator light stops blinking Then reconnect the AC cable and move the power switch to the On position This User Manual is updated regularly Please be sure to check aur support page fora newer version of this guide www koolance com support GENERAL PRECAUTION Please read this manual carefully before beginning the installation of your Koolance system This manual assumes the user has basic experiance in building and configuring computor systems Information referring to traditional hardware assembly is intentionally briet ABOUT SIGNS Throughout this document critical information is highlighted in gray colored boxes The following symbols are intended to prevent you from any situation
3. User Modification Needed Koolance Optional Pre Modified PSU Plate o mr o ana ANN mU Kootance User Manual 5 For most computer cases the PSU 1000ATX 12N must be installed from inside the chassis due to its width If you do not have a Koolance case please skip to the next section Most Koolance chassis must give up one hard drive cage in order to fit the PSU 1000ATX 12N Begin by removing the screws for this rear drive cage the top screws for the front hard drive cage and the PSU partition wall Screws are located above and below the hard drive area Remove the PSU partition wall and rear hard drive bay With the top screws of the front hard drive cage removed it should be possible to remove the rear drive cage by carefully fiexing the top partition without completely removing the front cage Support Bracket Bracket Wing Installation Carefully guide the power supply into the chassis per normal instalation Screw the PSU 1000ATX 12Nto the computer chassis PSU mounting The PSU 1000ATX 12N is supplied with an optional support bracket For chassis with top mounted power supplies above the motherboard the support bracket can help increase case stability Thebracketis screwed into the PSU s cable panel on the same side of the computer less frequently opened It is adjustable to meet the computer s side panel Velcro strips are provided to be applied in
4. Protection 43 3V 45V 12V Short Protection All output to ground Over Temperature Protection Heat sink 85 C Alarm 90 C Power Off Pump Protection Power Off on no RPM signal Environmental External Coolant Temperature 0 50 C Storage Temperature 10 to 70 C Humidity 20 90 RH Altitude 0 7000 feet 0 2134m Miscellaneous Compatibility EPSt2V MB Connectors 1 x 24 pin 2 x 8 pin Ax 6 pin PCIE 4x B pin PCI E Driver Connectors 2 x 4 plug SATA 2 x lug Molex Floppy Kootance User Manual Limited Warranty Koolance Incorporated Koolance warrants each new PSU 1000ATX 12N liquid cooled power supply the system against defects in materials or workmanship Tora period of three years trom the date of purchase and agrees to repair or replace any defective Koolance system without charge Shipping costs are non refundable This warranty is non transferable All warranty claims must be accompanied by the original proof of purchase THIS WARRANTY DOES NOT COVER DAMAGE RESULTING FROM ACCIDENT MISUSE OR ABUSE LACK OF REASONABLE CARE SHIPPING DAMAGE MODIFICATIONS THE AFFIXING OF ANY ATTACHMENT NOT PROVIDED WITH THE PRODUCT OPENING OF THE PRODUCT LOSS OF PARTS OR LIQUID OR OPERATING COMPONENTS AT SPEEDS OR FUNCTIONS OTHER THAN THOSE SPECIFIED BY THEIR MANUFACTURERS Use of unauthorized replacement parts or liquid additives wil void this warranty Koolance Incorporated will not pay for warranty service
5. between the bracker s flat wing and the computer chassis side panel Installation of the bracket is optional Kootance User Manual Tubing Connection Once the power supply is mounted inside the chassis insert and tighten the desired inlet and outlet nozzles purchased separately These should only be installed on the top nozzle sockets amp Attach the inlet and outlet tubing to the inlet and outlet nozzles m If you require the PSU 1000ATX 12N hoses to be connected inside the computer chassis install the supplied L bracket into an available rear card slot Feed the inlet and outlet hoses from the power supply heat exchanger back into the L bracket Finally connect these coolant hoses to your existing liquid cooling system To allow for sharper hose angles without kinking Koolance offers steel Tubing Wrap available at www koolance com Specifications AC Input Operating Range 110 240VAC Auto switching Frequency 47 83H2 Current 12A Q 110V 6A 240VAC PFC Active Efficiency 80 min DC Output Output Max 5V 30A 43 3V 30A combined 45V and 3 3V is 180W max 12V 70A 12V1 18A 12V2 18A 12V3 30A 12V4 30A 12V 08A 5VSB 3 0A Continuous Power 1000W Regulation 5 4 33V 5V 12V SVsb 9 5 12V Ripple amp Noise SOmV 3 3V SV 5Vsb 120mV 12V 240mV 12V Hold Time 16ms min PG Delay 100 500ms Safety OV Protection 3 3V 48V 12V OC
6. performed by a non authorized repair or diagnostic service and wil not reimburse tho consumer for damage resulting from warranty service performed by a non authorized repair service No responsibilty is assumed for any special incidental or consequential damages due to a defective Koolance product n order to obtain warranty service contact our RMA department for information The product must be shipped postage prepaid to an authorized Koolance service locaton It is suggested that for your protection you return shipments of product by insured mai insurance prepaid Damage occurring during shipment is not covered by this warranty Disclaimer IN NO EVENT SHALL KOOLANCE INCORPORATED OR ITS EMPLOYEES AGENTS SUPPLIERS MANUFACTURERS OR CONTRACTORS BE LIABLE FOR ANY DAMAGES OF ANY KIND OR CHARACTER INCLUDING WITHOUT LIMITATION ANY COMPENSATORY INCIDENTAL DIRECT INDIRECT SPECIAL PUNITIVE OR CONSEQUENTIAL DAMAGES LOSS OF USE LOSS OF DATA LOSS OF INCOME OR PROFIT LOSS OF OR DAMAGE TO PERSONS OR PROPERTY CLAIMS OF THIRD PARTIES OR OTHER LOSSES OF ANY KIND OR CHARACTER AND WHETHER OR NOT THE POSSIBILITY OF SUCH LOSS OR DAMAGE HAS BEEN NOTIFIED TO KOOLANCE INCORPORATED 10 KOOLANCE Printed in Korea
7. which may cause personal injury andor damage to equipment A could result in personal injury or be life threatening A CAUTION Indicates a potentially hazardous situation which not avoided may rest n damage to equipment OQ PROHIBITED Indicates a prohibited action PROHIBITED USE This product is designed developed and manufactured as contemplated for general uso Including without limitation general office use personal use and household use but is not designed developed and manufactured as contemplated for use accompanying fatal risks or dangers that unless extremely high safety is secured could lead directly to death personal injury severe physical damage or ather loss including without imitation nuclear power core control airplane control air traffic control mass transport operation control life support or weapon launching control If these products are used in such hazardous environments Koolance Incorporated does not warrant them TRADEMARKS The Koolance name andiogo ardthe Exo name andlogo are trademarks or registeredtrademarks cof Koolance Inc Other company and product names used inthis publication are for identification purposes only and may bo trademarks or registered trademarks of thor respective companies COPYRIGHT AI rights reserved Copyright C Kaolance Incorporated Kanrawre User Manual 1 EN A WARNING Never open the power supply expose the internal liquid coolan
8. acturer Koolance Contact Information Actress 2840 W Telephone Sales Ema Tech Email Wet sy Hoy N Auburn WA 98001 01 252 893 7551 Sales kooiance com lechQkoolanco com waw Koolance com Internal Connections The modular connections must match thelr appropriate plug on the PSU power supply unit Pay careful attention to the direction of each plug and notch while inserting as some are upside down Never force a plug into the PSU 12V 8 pi Motherboard Motherboard Main ATX SATA IDE PCLEspress Perphorais internal Temp Sensor PCLEgpress 4 x Erin 4 x enin Peripheral x 2 Cables SATAx 2 2x8pn Gables 4 Plugs Mainboard 12V Main ATX 24pin PSU Temperature Sensor intemal PSU coolant temp sensor is compatible with Koolance systems oniy PC3 Exos 2 and later Konano User Manual 3 External Connections DO Signa Light MsinaCPowerin Maio Power Switch Not used SV Fan Out fa Nae DO NOT OPENIN CAUTION The bottom internal coolant socket plugs must remain closed at all times Otherwise the sealed internal fluid will leak This liquid is not inexpensive and evaporates very quickly Tampering or pening the bottom internal coolant plugs will void the product warranty How the PSU 1000ATX 12N is Cooled The PSU 1000ATX 12N power supply is not a self dissipating product and must be connected to an existing liquid cooling system not included
9. t or remove the internal liquid coolant If liquid is removed the Power supply will be permanently damaged All warranties are voided upon opening the product or removing its liquid First aid measures are not anticipated if coolant ingestion has occured It irritation has occured with eye or skin contact flush with water for 15 minutes Remove contact lenses Call a physician if any irritation persists For further information please visit our website al wwwikoolance com CAUTION The PSU 1000ATX 12N power supply is not a selt dissipating product and must be connected to an existing liquid cooling system not included The power supply will overheat and may become permanently damaged if operated without proper cooling CAUTION Koolance Incorporated can not be held responsible for any damage to your system due to misconfiguration or incorrect installation Ii there is any point of installation that you do not understand please contact our Technical Support Staff at tech koolance com or visit our website at www koolance com support CAUTION Liquid cooling systems are not yet universally supported by hardware manufacturers In some situations adding liquid coolers and other components to computer hardware might void the manufacturer s original warranty Installation of the device is ultimately done at thte user s own risk If you have any specific questions on warranty coverage please contact your component or computer manuf