Home
Ilumiline Inground Tri-12 IP Optic 25 RGB Quick
Contents
1. 205 206 210 2110 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 25 255 lt lt lt lt No function Red 100 Green 0 100 Blue 0 Red 100 0 Green 100 Blue 0 Red 0 Green 100 Blue 0 100 Red 0 Green 100 0 Blue 100 Red 0 100 Green 0 Blue 100 Red 100 Green 0 Blue 100 0 Red 100 Green 0 100 Blue 0 100 Red 100 0 Green 100 0 Blue 100 Red 100 Green 100 Blue 100 White 1 3 200 K White 2 3 400 K White 3 4 200 K White 4 4 900 K White 5 5 600 K White 6 5 900 K White 7 6 500 K White 8 7 200 K White 9 8 000 K White 8 8 500 K White 9 10 000 K 6 Strobe 000 U 009 010 255 No function 0 20 Hz 7 Dimming Speed ARC 1 Channel Function 1 Red 000 U 009 010U 029 030 069 070 129 130 189 190 255 Value 000 U 255 Dimmer is set by Ilumicode OFF Dimmer is linear DIM1 Fastest dimmer curve DIM2 DIM3 DIM4 Slowest dimmer curve Percent Setting 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 10 llumiline Inground Tri 12 IP Optic 25 RGB QRG ARC D Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 U 255 0 100 4 Blue 000 U 255 0 100 SOLID Channel Function Value Percent Sett
2. Connection DMX In DMX Out IP67 Pin apie Ground Shield Shield 1 Data Black Green 2 Data White Red 3 llumiline Inground Tri 12 IP Optic 25 RGB QRG Ilumicon and The Ilumiline Inground Tri 12 IP Optic 25 RGB can operate with either an DMX Ilumicon or a DMX controller Use the standard DMX connection as shown on page 4 DMX Junction Box Wiring to connect this product to any of Controllers those controllers For more information please refer to the 77 Inground Tri 12 IP Optic 25 RGB User Manual Settings To configure the Ilumiline Inground Tri 12 IP Optic 25 RGB use the Tlumicode addresser llumicode The diagram below shows how to connect the Ilumicode to this product Connections Note that this connection will control multiple products at the same time all having the same DMX address To assign individual DMX addresses to each product you must connect the Tlumicode unit to each product individually You will also have to disconnect the DMX output of the product being configured if other products are connected to it O0OOOOOOO000 000000000000 Pi To llumicode Power other Connection fixtures Diagram 1 Gnd 1 Gnd Black clip 2 Data 2 Data Green clip 3 Data 3 Data Red clip DMX Output Signal Connector Ilumicode Addresser ILUMINARC suggests connecting no more than 20 products in this mode keeping the total distance to less than 60 m 197 ft If not you may
3. need to use an optically isolated signal amplifier llumiline Inground Tri 12 IP Optic 25 RGB QRG Installation Before mounting this product read the Safety Notes at the beginning of the Ilumiline Inground Tri 12 IP Optic 25 RGB User Manual and follow the mounting procedures Installation Diagram 1 Signal cable Power cable To signal distribution box To power distribution box Collar Concrete Drainpipe Hardpan llumiline Inground Tri 12 IP Optic 25 RGB QRG llumicode Button Function Control Panel lt POWER gt Turns the Ilumicode unit on Description lt MENU gt Scrolls through the main level or exits from the current menu or function NOTE Press and hold to turn the unit off lt ENTER gt Enables the currently displayed menu or sets the currently selected value into the selected function lt UP gt Navigates upwards through the menu options and increases the numeric value when in a function lt DOWN gt Navigates downwards through the menu options and decreases the numeric value when in a function Start Address To ensure full access to all channels in each DMX mode the highest recommended DMX addresses are as follows Mode Address Mode Address Mode Address SOLID ARC1 512 ARC1 D 509 SPECIAL1 507 510 ARC FULL 506 llumiline Ingr
4. 7 rated junction box make sure to use IP67 rated conduit Connection Wire US Wire Europe IP67 Pin AC Live Black Brown 1 AC Neutral White Blue 2 AC Ground Green Yellow Green Yellow 3 lOO OOOOOOOOOO OCOOOOOOOOOO0O L Black rom z o fuse N White other panel G Green boxes lt Distribution Conduit Distribution Box Box llumiline Inground Tri 12 IP Optic 25 RGB QRG DMX You connect the bare ended IP67 rated signal cable from this product to Connection two IP67 rated signal connectors DMX in and DMX Out or use an IP67 rated junction box If using an IP67 rated junction box make sure to use IP67 rated conduit To provide a signal for this product you can connect the bare ended IP67 Signal Wiring rated signal cable from the product to two IP67 rated signal connectors DMX in and DMX out or use an IP67 rated junction box If using an IP67 rated junction box make sure to use IP67 rated conduit The signal cable must match or exceed the electrical characteristics of the Belden 9841 cable for EIA RS 485 applications You can also use CAT 5 CAT 5e or CAT 6 99992999969 66 JO00000000000 1 Common Shield 2 Data In Black 3 Data In White 4 Data Out Green ox Wirlng 5 Data Out Red Signal Junction Junction in box Conduit box out DMX
5. Ilumiline Inground Tri 12 IP Optic 25 RGB Quick Reference Guide ILUMINARC llumiline Inground Tri 12 IP Optic 25 RGB QRG About This Guide Disclaimer Safety Notes What Is Included LN The lumiline Inground Tri 12 IP Optic 25 RGB Quick Reference Guide QRG only contains the product s connection and mounting information as well as the menu options and DMX values This QRG does not replace the product s User Manual You must download the corresponding User Manual from the ILUMINARC Web site www iluminarc com to learn about the disclaimers safety notes programming modes and technical information DO NOT open this product unless instructed It contains no user serviceable parts DO NOT look at the light source when this product is on DO NOT touch the product when it is operating because it may be hot DO NOT leave any flammable material within 50 cm from this product while operating or connected to the power outlet to minimize the risk of fire This product is for outdoor use and can be submerged IP67 However do not submerge deeper than 1 m for more than thirty 30 minutes DO NOT operate this product if you see damage on the housing lenses or cables Have an authorized technician replace the damaged parts DO NOT connect this product to a dimmer or rheostat ONLY connect this product to a grounded and protected circuit One Ilumiline Inground Tri 12 IP Optic 25 RGB One Power Input Cable b
6. are ended One Data Input Output Cable bare ended One Installation Sleeve One Pour Kit Cover One Warranty Card One Quick Reference Guide The RDM2g0 which includes a built in ilumicode addresser along with many other useful features is now available The Ilumicoode addresser is required for product configuration sold separately llumiline Inground Tri 12 IP Optic 25 RGB QRG Features Options 1 3 4 6 or 7 channel DMX 512 LED inground wash light Operating modes 1 channel Dimmer 3 channel RGB control 4 channel Dimmer RGB control 6 channel RGB control per module two modules 7 channel Dimmer RGB control color macros strobe dimmer speed Five distinct dimming curves IP67 stainless steel gland nuts for cable entry Remotely addressable with Ilumicode Addresser IP67 ingress protection Gore valve ADA compliant skid resistant drive over rated glass lens cover High power 3 W 1 050 mA Tri color LEDs Ilumicode addresser required for product configuration Ilumicon controller for operation without DMX controller llumiline Inground Tri 12 IP Optic 25 RGB QRG AC Power Power Wiring Power Cable Table AC Power Junction Box Wiring This product has an auto ranging power supply that works with an input voltage range of 100 240 VAC 50 60 Hz You can connect the bare ended IP67 rated power cable from the product to an IP67 rated power connector or use an IP67 rated junction box If using an IP6
7. equest support or to return a product Visit our website for contact details Ilumiline Inground Tri 12 IP Optic 25 RGB QRG Rev 07 UL 1573 Copyright 2015 ILUMINARC CSAC22 2No 166 All rights reserved 5 5113093 Printed in the P R C 12
8. ing 1 Dimmer 000 255 0 100 SPECIAL 1 Channel Function Value Percent Setting 1 Red Module 1 000 255 0 100 2 Green Module 1 000 255 0 100 3 Blue Module 1 000 255 0 100 4 Red Module 2 000 255 0 100 5 Green Module 2 000 U 255 0 100 6 Blue Module 2 000 255 0 100 11 llumiline Inground Tri 12 IP Optic 25 RGB QRG Contact USA WORLD HEADQUARTERS Us General Information ILUMINARC Technical Support Address 5200 NW 108th Avenue Voice 800 762 1074 Sunrise FL 33351 Email support iluminarc com Voice 954 923 3680 Fax 800 544 4898 World Wide Web www iluminarc com EUROPE General Information Chauvet Europe BVBA Technical Support Address Stokstraat 18 Email Eutech chauvetlighting eu 9770 Kruishoutem Belgium World Wide Web Voice 32 9 388 93 97 www chauvetlighting eu General Information Chauvet Europe Ltd Technical Support Address Unit 1C Email uktech iluminarc com Brookhill Road Industrial Estate Pinxton Nottingham UK World Wide Web NG16 6NT www chauvetlighting co uk Voice 44 0 1773 511115 Fax 44 0 1773 511110 MEXICO General Information Chauvet Mexico Technical Support Address Av Santa Ana 30 Email servicio iluminarc com mx Parque Industrial Lerma Lerma Mexico C P 52000 World Wide Web Voice 52 728 285 5000 www chauvet com mx Outside the U S United Kingdom Ireland Mexico or Benelux contact the dealer of record Follow their instructions to r
9. ound Tri 12 IP Optic 25 RGB QRG Menu Options Main Level Programming Levels Description DMX 001 512 N A Sets the DMX starting address PERSON ARC1 3 channel RGB control ARC1 D 4 channel RGB control dimmer ARC FULL NIA 7 channel RGB control dimmer REMOTE Allows using the ILUMICON unit SOLID 1 channel dimmer SPECIAL1 6 channel RGB per module CALIB Determines the white balance for WHITE 11 RED the color macros GREN 0 255 8 bd BLUE etermines the white balance ROR TOM when RGBTOW is active DIMMER OFF Dimmer work in linear mode DIM 1 DIM 2 N A Dimmer works in non linear DIM 3 mode from fast to slow DIM 4 STATIC RED GREN Configures the static color and 0 255 BLUE effect STRB SETTINGS Maximum output unbalanced OFF white White output is as per CALIB gt COLOR RGBTOW RGB settings UC Output matches that of product s previous versions RESET NO YES llumiline Inground Tri 12 IP Optic 25 RGB QRG DMX Values ARC FULL Channel Function Value Percent Setting 1 Dimmer 000 U 255 0 100 Red 000 255 0 100 Step Time if CUS 01 10 active 000 255 0 100 Fade Time if CUS 01 10 active 2 3 Green 4 Blue 000 255 0 100 5 Color Macros 000 010 011 030 051 071 091 111 131 151 070 090 110 130 170 1710 200 201