Home
DREAM Sidecar Installation and User Manual
Contents
1. The warranties remedies and disclaimers above are exclusive and take precedence over all others oral or written express or implied to the extent permitted by law in the geographical area of the product s use No employee of Fairlight ESP agent distributor or employee of an agent or distributor is au thorized to offer any variation from this policy Copyright 2002 Fairlight ESP Pty Ltd Unit 2 1 Skyline Place French s Forest NSW 2086 AUSTRALIA Telephone 61 2 8897 9999 Fax 61 2 8897 9900 OBTAINING TECHNICAL SUPPORT Users requiring technical support should contact their local Fairlight office or dis tributor Information can also be found on the world wide web at http www fairlightesp com FAIRLIGHT OFFICES WORLD WIDE USA West Coast Fairlight USA 844 North Seward Street Hollywood CA90038 USA Tel 1 323 465 0070 Fax 1 323 465 0080 United Kingdom Fairlight ESP Limited Unit 12 Spectrum House 32 34 Gordon House Road London NW5 1LP England Tel 44 20 7267 3323 Fax 44 20 7267 0919 Germany Fairlight Deutschland Gmbh August Bebel Strasse 26 53 14482 Potsdam Babelsberg Berlin Germany Tel 49 331 721 2930 Fax 49 331 721 2933 Asia Pacific Fairlight ESP Pty Ltd Unit 2 1 Skyline Place Frenchs Forest NSW 2086 Australia Tel 61 2 8977 9999 Fax 61 2 8977 9900 MANUAL ERRORS AND OMISSION USA East Coast Fairlight USA 2 West 45 Street Penthouse New York NY 10
2. Pause Break and type SU Enter to enter super user mode Step 2 Use the trackball to click on the Binnacle Cut key to launch Cons con the console configuration utility Alternatively click on My Computer on the Windows desktop and navigate to C Projects mixers fmc system Cons con exe Step 3 Select Station console type and click the Add Panel button to add panels one at a time Step 4 Select panel number Panel 4 then select StationMainMeters type Click OK to add the panel To remove an accidentally added panel select the panel and click Remove Panel To modify a panel select the panel and click Modify Panel Exit Console Type Station y dd Save Panel ld Add Panel x ps Modify Panel StationMainMeters Cancel Delete Panel Remove All Figure 2 ConsCon Window LCD Calibration To calibrate the contrast on the Meter Panel LCD run FMC Hold down the Shift key and press the Pause Break key Shift Pause Break toggles the keyboard focus between FMC and the QDC engine then type U This will bring up the calibration window INSTALLATION 2 4 Testing and Calibration i E xi da Type E Number Encoder omes Fader Produd Joystick LCD CtSwitch Touch LED Touch Sensor PCB Serial Number Test COMI Test COM2 Test GPIOs Figure 3 Console Calibration Dialogue The Meter Panels should be selected from the Panel drop down list and the
3. SUE ims 3 2 DIMENSIONS AND WEIGHT 0 0000 eee RR RR Res 3 2 DREAM Station Main Meter Panel LL 3 2 deta a a essen aeneon 1 TABLE OF CONTENTS 1 1 Chapter 1 Introduction INTRODUCTION The DREAM Station Main Meter Panel provides high resolution signal level me tering for the Fairlight DREAM Station integrated mixer editor The Station is part ofa new family of products from Fairlight which marries together QDC processing with an ergonomic physical control surface in a combination that has a significant impact on productivity and efficiency The Station and Station Sidecar combina tion offers a flexible and scaleable solution to a range of audio production and post production tasks ABOUT THIS MANUAL The DREAM Station Meter Panel Installation Manual provides the information necessary to install and operate the unit with a DREAM Station This manual should be used in conjunction with the DREAM Station Installation and User Manual to obtain complete instruction in the use and installation of the complete system This manual is designed to familiarize sound editors and engineers with the facilities provided by the Station Main Meter Panel The terminology and concepts used in this manual assume a reasonable knowledge regarding audio principles and studio procedures USING THE STATION MAIN METER PANEL The Station Main Meter Panel includes eight 55mm multi segment bargraph LED signal level meters plus eight LCD meter
4. mm 21 85 50 mm 2 120 mm 4 7 215 mm 8 5 85 mm 3 4 2 5 kg WIRING AND CONNECTION DETAILS Index i Index A Add Panel 2 3 AMIXI19 A wo cece ee eee 2 2 C Calibration 2 3 Configuration siste ili 2 2 Connecting ze leer 2 2 Cons con Li 2 3 D Depth utes ek used ues kur 3 2 Dimensions o o o o ooo o 3 2 DREAM Start 2 3 F Fairlight Offices ies ur be tush 3 ii Found New Hardware 2 3 H A ide bits 3 2 L LCD Calibration 2 3 M Manual Errors and Omission 3 ii Mechanical Installation 2 2 Meter wenn 2 2 Modify Panel dint cicala ola 2 3 R Remove Panel ans keen pr 2 3 S Specifications s d ees uis 3 2 Station Sexe s Ae P ADS ARS 2 2 T Technical Support 3 ii USB As tea ne 2 2 3 2 USB Installation babor 2 3 Using the Meter Panel 1 1 W Weight lora pad adas 3 2 Midas 3 2 NA yass 3 2 X Rioni EET 2 2 INDEX
5. 036 USA Tel 1 212 819 1289 Fax 1 212 819 0376 France Fairlight France 41 43 Rue des Peupliers 92100 Boulogne Billancourt Paris France Tel 33 1 4610 9292 Fax 33 1 4610 9295 Japan Fairlight Japan Inc 3 3 11 Ikejiri Setagaya Ku Tokyo Japan 154 0001 Tel 81 3 5432 4151 Freecall Japan only 0120 213 643 Fax 81 3 5432 4533 To help ensure that Fairlight provides the most accurate and comprehensive docu mentation please report any errors or omissions to documentation fairlightesp com au Table of Contents Chapter 1 Introduction INTRODUCTION vr d pod p 0 d ARE RI EI SIDE VAT VR d 1 1 ABOUT THISMANUA L ee IH reinen 1 1 USING THE STATION MAIN METER PANEL 2 acd sca em ee ni EXC afew e od 1 1 Chapter 2 Installation INTRODUCTION A gira a em rebut ERIS pam Ii Uis 2 2 MEGHANIGALINSTALEATIONI deat aree ein eh REDE RUE nen Deis 2 2 CONNECTING THE STATION METER PANEL eR RR RR RR 4s 2 2 CONFIGURATION coat ae ee estos toit ole MOOR Bue dra ease d betel dut de bale dosi dus a 2 2 USB Installation Zinio Ai ete dee e ode e ach Do dote t e i 2 3 EONSSCON TER HE RR MEC uw LR Mb Tn LOUER HEIN DO 2 3 I CD Galibratlonzs i eter een WE alee nenn edat ded te e bt a 2 3 TESTING AND CONMDMISSIONIN G d rta Debo e b Done e ao e Ce bee n e re RU De egt 2 4 Chapter 3 Specifications WIRING AND CONNECTION DETAILS 000 eee RR IRR Res 3 2 Meter USB entibus ols cote Ue RP Eee e a x ad
6. DREAM Station sMP1 Station Main Meter Panel Installation Manual DREAM Software Version 1 1 Part No DBE1104 A Document No 214 i Important Notice COPYRIGHT The material in this document is copyright to Fairlight ESP Pty Ltd and may not be quoted or re produced in any form without written permission from the company Fairlight is a trademark of Fairlight ESP Pty Ltd All other trademarks are the property of their re spective owners LIMITED WARRANTY POLICY All the software and hardware provided with or purchased especially for Fairlight products has been tested for functionality Fairlight ESP Pty Ltd will make its best efforts to correct reported defects for future releases subject to technical practicabilities Fairlight ESP will also replace any defective media on which software has been delivered provided that the item to be replaced is returned to the dealer who supported the product within 90 days of purchase Fairlight ESP Pty Ltd makes no warranty or representation either expressed or implied with respect to the system s performance or fitness for a particular purpose In no event will Fairlight ESP Pty Ltd be liable for direct or indirect damages arising from any defect in the product or its documentation Further Fairlight ESP Pty Ltd will not accept any liability for any programs sounds audio recording or sequences stored in or used with Fairlight products in cluding the cost of recovery of such data
7. ect the 5 pin XLR USB cable part no AMIX119 A from the female XLR labelled Meter on the rear of the Station to the male XLR on the Station Main Meter Panel CONFIGURATION If the Meter Panel has been purchased separately from the Station the Station must be configured to establish communication with the Meter Panel via USB Follow these steps to configure the Meter Panel 1 Connect the Meter Panel prior to turning on the Station 2 Turn on the Station During start up Windows will detect the new Meter Panel hardware Install the USB drivers as described below 3 Run the console configuration utility Cons con to add the Meter Panel to the Station configuration 4 Finally run the FMC calibration utility to calibrate the Meter Panel LCDs INTRODUCTION 2 3 USB Installation The USB driver for the Meter Panel must be installed the first time it is connected to the system Step 1 Ensure the Meter Panel is connect to the Station and that the Sta tion is running Step 2 During boot up the Windows Found New Hardware dialog box will appear Click the Browse button and navigate to the follow ing directory CADREAM Drivers USB drivers W2000 Select FairUsb inf and click OK to complete the driver installation Cons con The Meter Panel must be added to the Station console configuration This is achieved with the Cons con application Step 1 While the DREAM Start splash screen is displayed hold down the Shift key and press
8. legend windows The Station Main Meter Panel displays the signal level of each element of the Main bus The name of each element is displayed in the LCD window below each bargraph The number of active bargraphs is determined by the user defined format of the Main bus For example if the Main bus format is stereo only LEFT and RIGHT bus element meters are displayed If the Main bus format is 7 1 all eight elements are displayed These are LEFT INNER LEFT CENTRE INNER RIGHT RIGHT LEFT SURROUND RIGHT SURROUND BOOM The Station Main Meter Panel displays peak program level INTRODUCTION NOTES 2 2 Chapter 2 Installation INTRODUCTION The DREAM Station Main Meter Panel is designed to be mounted directly to the rear of the DREAM Station One simple cable connection between the Station and Meter Panel using the five pin XLR cable supplied is also required MECHANICAL INSTALLATION Tools Required 1 x 2 Pozi drive screw driver Step 1 Carefully unpack the Station Main Meter Panel Step 2 Remove the two screws on the rear of the Station as indicated below Step 3 Align the Station Main Meter mounting brackets with the mount ing holes Step 4 Fasten the mounting brackets by re inserting the screws and tight ening Meter Panel Meter Connector Mounting Screws Figure 1 Station Console Rear Panel Connections CONNECTING THE STATION METER PANEL Step 1 Conn
9. n cali brated as described below If correctly entered in Cons con the panel is listed as Panel 4 StationMainMeters Select LCD from the Type list LCDs 1 to 4 are adjusted by LCD number 3 LCDs 5 to 8 are adjusted by LCD number 7 Select 3 or 7 from the Number list then click Go The LCD dialogue box will be displayed Click the Contrast buttons to change the contrast Click the Backlight buttons to change the backlight level Click OK to move on to the next LCD x LCD Name Fader Panel ID LCD Contrast x 23 Skp Contrast Contrast Exit LCD Backlight 46 Backlight Backlight Figure 4 LCD Calibration Window TESTING AND COMMISSIONING Once the Station Main Meter has been installed configured and calibrated refer to the Station manual for operational procedures that will assist in testing its operation within the studio environment TESTING AND COMMISSIONING 3 1 NOTES 3 2 Chapter 3 Specifications WIRING AND CONNECTION DETAILS Connector sex described is the panel mount connector on the rear of the unit Meter USB Description USB and DC Power connection Connector 5 Pin XLR Male XLR5 SIGNAL PAIR PIN 1 USB 1 PIN 2 0V PIN 3 12V PIN 4 0V PIN 5 USB 1 SHELL SHIELD 1 DIMENSIONS AND WEIGHT DREAM Station Main Meter Panel Width Depth Height Fitted Height Fitted Depth from rear of Station Net Weight 555
Download Pdf Manuals
Related Search
Related Contents
Gamme Michelin Compétition 平成24年 3月5、6日フランス国パリ西郊クールブヴォア市ISO/TC 127 物言わぬ駒のように - タテ書き小説ネット Copyright © All rights reserved.
Failed to retrieve file