PHARUS user manual eng rel 1.2.cdr
Contents
1. 3 Manual Rel 1 2 GB 4 The Lighting Company D T S Illuminazione srl ITALY http www dts lighting it Made in Italy 2 PHARUS Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non assunta alcuna responsabilit per eventuali inesattezze Tutti i diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous droits r serv s
2. Mechanical parts Periodically check all mechanical parts Periodically check the lubrication of all components particularly the parts subject to high temperatures If necessary lubricate with suitable lubricant available from your D T S distributor Electrical components Check all electrical components for correct earthing and proper connection of all connectors refastening if necessary Fuse replacement Locate the fuse which protects the lamp and electronics in the balast of the PHARUS Using a multimeter test the condition of the fuse replacing it with one of equivalent type if necessary Attention Disconnect mains power prior to removing the projector housing 16 PHARUS DISPLAY FUNCTIONS PHARUS ELECTRONIC BALLAST DFP Digital Function Panel MENU ENTER DOWN DISPLAY FUNCTIONS The PHARUS ELECTRONIC BALLAST display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol IS shows which key has to be pushed to obtain the desired function IB S C MEM MENU UP Software version 2 10 IS E gt S MENU Up Down ENTER Up Down TIMER Visualization of lamp life reset possible and total time
3. unit s working reset not possible BALLAST LIFE TIME HOURS a m 4 m A a BALLAST LIFE TIME MINUTES Up Down m 4 m A ui arl IS LAMPLIFETIMEHOURS IS MLNII Up Down j AD is Era an gt LAMP LIFE TIME MINUTES orrs IS 13 ML LL ane MANIP STRIKE IS IS IS O0 N Orme MENU Up Down ENTER Up Down f 00008 ENTER Up Down bI NOMINAL LAMP POWER BALLAST MONITOR ES Uoue a osm LUOOO came VOLTAGE IS I AAN Up Down ENTER Up Down LLL LAMP CURRENT IF oer 11 I IS TO RESET Up Down LI IL ENTER Up Down LILIO 1 cen POWER SUPPLY TEMP PFC SIDE gt dLd LAA TO RESET Up Down COL LI COL I i ENTER Up Down POWER SUPPLY TEMP DC DC SIDE DMX MODE To select DMX mode 9 default 6 AUX CUSTOM LAMP ON OFF lamp amp MENU Up Down SOFTWARE Software version 13 HIDDEN MENU For technical personnel only To operate this menu MENU Up Down ES ES Down ES UN Down ES SS Down Up Down ES is Down Addi II iN DS Addi ENTER e Lor Lz ENTER 17 ENTER Up Down Up Down ENTER PHARUS INSERT PASSWORD DEFAULT 1500 AGG e C MEM SHOW AND CHANGE DMX ADDRESS FORCED LAMP OFF FORCED LAMP ON SOFTWARE VERSION Enter in Ballast monitor Mon b select sec n enter the default code 1500 and Press C MEM menu up BALLAST MONITOR E C MEM MENU Up Down ENTER Up Down ES Es Down MENU Up Down ENTER Up Do
4. 5 1 Protection against liquids The projector contains electric and electronic components which should under no circumstances come into contact with oil water or any other liquid The proper unit functioning would be compromised should this occur 10 PHARUS 5 2 Movement The projector has a maximum vertical movement of 45 A A ey Y Knobs for vertical position adjustment 5 3 Risk of fire Each fixture produces heat and must be installed in a well ventilated place The minimum recommended distance from flammable material is 1 MT Minimum distance from the object being illuminated is 2 MT 5 4 Forced ventilation You will note on inspection that the PHARUS features various air inlets and cooling fans located on both ballast and projector These should under no circumstances be blocked or obstructed whilst the projector is in operation Doing so could cause the fixture to seriously overheat thereby compromising its proper operation 5 5 Ambient temperature The projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 6 MAINS CONNECTION PHARUS with electronic ballast operate at 90 260 VOLT 50 60 Hz PHARUS with electromagnetic ballast operate at 220 240 VOLT 50 60 Hz or 110 V 50 60 HZ Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available For connect
5. Ce document ne peut tre copi photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esthetiques fonctionnelles ou de design sans pr avis a chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci nescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de dise o a cada producto suyo D T S no se asume responsabilidad de ning n tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos 3 PHARUS INDEX 1 TECHNICAL FEATURES 4 2 IMPORTANT SAFETY INFORMATION 6 2 1 Fire prevention 2 2 Prevention of electric shock 2 3 Protection against ultraviolet radiation 2 4 Safety 2 5 Level of protection against the penetration of solid and liquid objects 3 MOUNTING THE LAMP 7 3 1 Lamp alignment 4 VOLTAGE AND FREQUENCY 8 5 INSTALLATION 9 5 1 Protection against liquids 5 2 Movement 5 3 Risk of fir
6. Cod 03 TP005 120 L Magnetic ballast 110V 50 60Hz PHARUS 1500 EB Cod 03 TP005 EB L Electronic ballast 90 260V 50 60Hz PHARUS 1200 Cod 03 TP009 L Magnetic ballast 220 240V 50 60Hz PHARUS 1200 Cod 03 TP009 120 L Magnetic ballast 110V 50 60Hz PHARUS 1200 EB Cod 03 TP009 EB L Electronic ballast 90 260V 50 60Hz Lamp Lamp HTI 1500W D7 60 PHARUS 1500 HMI 1200W S PHARUS 1200 Base SFc 10 4 with notch 5 PHARUS 1 TECHNICAL FEATURES Optical group New optical group with condenser lens Zoom 7 16 Linear focus Extractable iris diaphragm Mechanical dimmer with black out Colours Colour changer optional 5 interchangeable gel filter holders Automatic switching system between colours Gobos Gobo holder for gobo projections optional Construction Made on aluminium and stainless steel High resistance to heat and mechanical stress Removable cover for easy access to lamp Safety Safety microswitches Power supply 220 240V 50 60Hz electromagnetic ballast version 90V 260V 50 60Hz electronic ballast version Power consumption 1600 VA with built in power factor correction External ballast electromagnetic or electronic Weight 21 2 Kg PHARUS 22 8 Kg PHARUS with colour changer 7 Kg electronic ballast 19 Kg electromagnetic ballast Dimensions LxWxH Projector 996 x 381 x 466mm Projector with colour changer 1108 x 381 x 466mm Ballast electromagnetic 300 x 251 x 269mm electronic 400
7. e 5 4 Forced ventilation 5 5 Ambient temperature 6 MAINS CONNECTION 10 6 1 Protection 7 OPENING THE PROJECTOR HOUSING 11 8 IRIS REPLACEMENT 12 9 PROJECTOR USE 13 9 1 Focus and Zoom 9 2 Iris and Dimmer 10 PERIODIC CLEANING 15 10 1 Lenses and reflector 10 2 Fans and air passages 11 PERIODIC CONTROLS 15 12 DISPLAY FUNCTION 16 13 HIDDEN MENU 17 4 PHARUS 1 TECHNICAL FEATURES PHARUS is the latest evolution of the D T S follow spots range PHARUS is a new follow spot ideal for all professional applications theatres concerts television studios fashion displays special events etc PHARUS offers a distinct improvement in projection quality thanks to a new optical group with condenser lens PHARUS is available in two models PHARUS 1500 fitted with a 1500 W discharge lamp and PHARUS 1200 fitted with a 1200 W discharge lamp PHARUS offers also a series of updated functions that ensure effective and creative use New customizable colour system 5 interchangeable gel filter holders Linear iris diaphragm extractable Linear zoom 7 to 16 Linear focus Mechanical dimmer with black out PHARUS is designed to resist all the rigours of continuous use the body is made in aluminium and stainless steel which offer high resistance to heat and mechanical stress PHARUS is complete with external ballast electromagnetic or electronic PHARUS 1500 Cod 03 TP005 L Magnetic ballast 220 240V 50 60Hz PHARUS 1500
8. iolet radiation Never turn on the lamp if any of the lenses or filters are damaged Their respective shielding functions will only operate efficiently if they are in perfect working order Never look directly the lamp when it is on 2 4 Safety The external surface of the unit at various points may exceed 70 C Always wear suitable hand protection when handling the unit Always replace the lamp if any physical damage is evident Never install the fixture in an enclosed area lacking sufficient air flow The ambient temperature should not exceed 40 C A hot lamp may explode so always wait for at least 10 minutes prior to attempting to replace the lamp Always wear suitable hand protection when handling the lamp 2 5 Level of protection against the penetration of solid and liquid objects The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20 7 PHARUS 3 MOUNTING THE LAMPS Warning Switch off the unit before replacing the lamp Osram HTI 1500W D7 60 Osram HMI 1200W S Power 1500W Power 1200W Luminous flux 145 000 Im Luminous flux 110 000 Im Colour temperature 6 000 K Colour temperature 6 000 K Lampbase SFc10 4 Lampbase SFc10 4 Rated life 750 hours Rated life 750 hours 1 Loose the two screws located on the rear side of the unit photo 1 Photo 1 Photo 2 Photo 3 2 Remove the cover photo2 3 Insert the lamp on the lam
9. ion purposes ensure that your plug is capable of supporting 8 amps at 220 240V Electromagnetic ballast Or 16 amps at 110 V 220 240 V 50 60 Hz Strict adherence to regulatory norms is strongly recommended or 110 V 50 60 Hz 6 1 Protection The use of a thermal magnetic circuit breaker is recommended for each PHARUS A good earth connection is essential for the correct operation of the projector Electronic ballast 90 260V 50 60Hz Main AC Panel connector 11 PHARUS 7 OPENING THE PROJECTOR HOUSING It is possible to inspect the inside of the projector by opening the covers as indicated below ATTENTION REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR S INTERNAL COMPONENTS REAR SIDE 1 Loose the two screws located on the rear side of the unit photo 1 2 Remove the cover photo2 Photo 1 Photo 2 FRONT SIDE 1 Loose the screws located on the bottom front side of the unit photo 1 2 Now it is possible to move the covers for internal inspection photo2 and 3 Photo 1 Photo 2 Photo 3 12 8 IRIS REPLACEMENT ATTENTION REMOVE MAINS POWER PRIOR TO PERFORMING THE IRIS REPLACEMENT 1 Move the dust cover toward the front of the unit photo 1 2 Push the iris security lock photo2 3 Pull up the iris assembly photo 3 Photo 1 Photo 2 Photo 3 13 PHARUS 9 PROJECTOR USE 9 1 Focus and Zoom Focus and zoom adjustment lenses are located on the front side of the u
10. nit Place the projector on the object to illuminate loose the fixing lenses knobs adjust the lenses position till the projection is whell focused on the object Thighten the knobs FOCUS ZOOM FOCUS ZOOM 14 9 2 Iris and Dimmer Iris and Dimmer are located on the front side of the unit Move the iris from left side to right side to reduce the projected area photo 1 and 2 Move the Dimmer from right side to left side to reduce the light output intensity till blackout photo 3 and 4 Photo 1 Photo 2 FULL FULL OPEN CLOSED Photo 3 Photo 4 PHARUS 1500 DIMMER FULL closed 15 PHARUS 10 PERIODIC CLEANING 10 1 Lenses and reflectors Even a fine layer of dust can reduce the luminous output substantially Regularly clean all lenses and the reflector using a soft cotton cloth dampened with a specialist lens cleaning solution 10 2 Fans and air passages The fans and air passages must be cleaned approximately every 6 weeks This periodic cleaning will depend of course on the conditions in which the projector is operating Suitable instruments for performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor If necessary clean the fans and air passages more frequently 11 PERIODIC CONTROLS Lamp The lamp should be replaced if there is any visible damage or deformation due to heat This will help to avoid the danger of the lamp exploding
11. no Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
12. p socket and tighten the lamp screws photo 3 The lamp used on PHARUS 1500 is made in quartz glass and should be handled with care Always follow the instructions supplied in the lamp s packaging Never touch the glass directly but use the tissue provided in the lamp s packaging The lamp socket is symmetrical DO NOT USE UNDUE FORCE ON THE GLASS In case of difficulty read again the instructions and repeat the procedure 3 1 Lamp alignment The lamp socket is self centering So there is no need to allign the lamp 8 PHARUS 4 VOLTAGE AND FREQUENCY The PHARUS with electromagnetic ballast operates at 220 240 VOLT 50 or 60 Hz available also at 110 VOLT 50 or 60 Hz Please note that Electromagnetic Ballast can not be use in Pharus 1500 EB Electronic ballast On Off switch Main Ac Panel connector Fuse Proiector Fans speed holder regulation connector knob socket The PHARUS with electronic ballast operates at 90 260 VOLT 50 or 60 Hz Please note that Electronic Ballast can not be use with pharus 1500 Electromagnetic ballast On Off switch Main Ac Panel connector Projector connector socket holder 9 PHARUS 5 INSTALLATION PHARUS should be floor mounted The unit is provided with a bracket for fixing to floor stand The floor stand from which the unit is fixed should be capable of bearing the weight of the unit petali c gt B Bracket for fixing the unit Pa to floor stand
13. wn ENTER Up Down Up Down Up Down Up Down Up Down ENTER Up Down E ELLU S ES IS IS MENU UP CUAL Y O I CUAL IL Is Es Down I IS oun doun nm ES Es Down 4 136 R IS IS ES MEM MENU UP RESET TIME AND STRIKE LAMP JC RESTORE FACTORY SETTING I_C IS DOWNLOAD SOFTWARE UPLOAD SOFTWARE PL ols ENTER is Down l te m f N24 CHANGE PASSWORD ES cs Down 6 ENTER Up Down C MEM Fold IS Fout 3 FSE ds ENTER Up Down IS Fold ME ES is Down CHANGE FREQUENCY OUTPUT r 136 E r 136 ENTER ls ES Down SUE Fr IS MEM LAMP POWER 18 Note 19 Note The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent fromD T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY C E The Lighting Company ISO 9001 2000 D T S quality system is certified to the ISO 9001 2000 standard D T S products are designed and manufactured at the D T S plants in Italy 05171084 D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misa
14. x 251 x 220mm 466 mm Projector Packaging Ballast Packaging Dimensions H Dimensions LxWxH LxWxH J 1200 x 450 x 500 mm 350 x 300 x 310 mm e HU Weight Weight L F 23 2 Kg 20 5 Kg electromagnetic 8 5 Kg electronic 6 PHARUS 2 IMPORTANT SAFETY INFORMATION 2 1 Fire prevention PHARUS 1500 uses a Osram HTI 1500W D7 60 PHARUS 1200 uses a Osram HMI 1200W S The use of any other alternative lamp is not recommended and will null and void the fixture s warranty Never locate the fixture on any flammable surface Minimum distance from flammable materials 1 MT Minimum distance from the closest illuminable surface 2 MT Replace any blown or damaged fuses only with those of identical value Refer to the wiring diagram if there is any doubt Connect the unit to mains power via a thermal magnetic circuit breaker 2 2 Prevention of electric shock High voltage is present inside the unit Unplug the unit prior to performing any function which involves touching the inside of the moving head including lamp replacement The level of technology inherent in the PHARUS requires the assistance of specialised personnel for all servicing Please refer to an authorised DTS service centre A good earth connection is essential for proper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 2 3 Protection against ultrav