Home

Installation Manual VID-W03-L100 Vista Infra-Red

image

Contents

1. Installation Manual VID W03 L100 Vista Infra Red Detector Long Range Curtain A Detector for Outdoor Perimeter Protection Manual VID W30 L100_3 2008 doc page 1 10 www norbain co uk Table of Contents Page T MUOdUCHUOM en TEE AAN EE 3 2 FOAWICS AEE EEA AA EAE ENA 3 3 MOUNTING and Installation asssansnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn mnnn 3 4 Connecting the VID W 03 L100 as nnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn nnmnnn nnmnnn 3 5 Alarm SIANO ee E ees emeenocee vocecieveesscereueus 3 o Fedor VIEW cesena eet sennaea eee une ccu ances cose tuendeseneb anecicneens cap esateccenedesnnacaeseceees 3 DPR CUIINC I oases eres goes eben E E 3 7 1 Vertical alignment of VID W03 L100 for a required detection up to nominal range cccceeeeeeeeeeeeeeee es 4 7 2 Horizontal alignment of VID WO03 L100 0 0 0 0 cceeccccceeeeeeeeeeeeeeeeeeeeesseeeeeseeeeeeseaeeeesseaeeeeseeeeeesaeeeessaaeeessaess 4 8 Sensitivity SO LUI Sioa cise rds esc ewe ane tac peersenene deca eemeemsin ed eemsuasmeuncanbreuscuscncucroteraeeeenmiedemaademcceeen 4 9 Adaptive Threshold Discrimination ATD ccccccssesseseeceeeecesesceseeeenseseneeeoesseeensenensesonsesoeneees 5 10 SU ae rere creed na tec ee ves en ened ne een enemies en OE 5 11 Anti Vandal Function AVF cececsicncs cece cose ce tne ceiateecaene eee catec es cec eet eccce eenceteneseveuveneu
2. 12 Mounting Height The VID W03 L100 is designed for mounting at heights between 2 5 and 4 0m above ground The seventh DIP Switch is used to set the relative sensitivity of all detection zones in function of the mounting height as recommended below Switch 7 Mounting Height off LOW lt 3 0m on High gt 3 0m Factory Setting Manual VID W30 L100_3 2008 doc page 5 10 www norbain co uk If the mounting height is less than 2 5m a detection gap at app 10m distance may be observed for fast movements This is due to the overlap of the three zones and resulting rejection of simultaneous signals 13 LED The electronic board is fitted with a dual LED having a red and green colour side This can be monitored during installation while the cover is open The red LED on indicates that the detector is in an alarm state The green LED flashing at 2 Hz frequency indicates the detector ready state During the turn on time the red LED is on 14 Alarm Time Alarm time per event is determined by the duration of the detected event and depends on the shape and amplitude of the alarm signal Individual alarm pulses have a minimum time of approximately 2 5 seconds 15 Internal Temperature Compensation The VID W03 L100 is detecting the radiation differences of a target against its background In the course of a day and a year the contrast of a person will vary considerably and affect the signal strength To compensate for this
3. see appendix 19 1 5 Alarm Signalling There are two types of alarm outputs on the VID W03 L100 one SPST potential free relay contact one open collector transistor output Cover Switch A tamper detection switch is fitted for the cover this contact opens when the cover is opened 6 Field of View The VID W03 L100 has a curtain shaped field of view with independent detection channels for short medium and long range detection The vertical opening angle is app 26 resulting in an uninterrupted curtain starting at app 8 m with the detector mounted at 4 0 m 13 ft height The nominal ranges and widths at nominal range refer to the table below VID W03 L100 Nominal Range 100m 330 feet Width at Nom Range 3m 10 feet 7 Alignment The detection range of a PIR detector is not limited but it is a function of the target size soeed and temperature contrast against its background The VID W0O3 L100 should be aligned so that a natural or artificial background at the end of the range terminates the field of view Vertical alignment is optimal when the upper edge of the field of view is at 1 5 to 2 5m 5 to 8 ft above ground at the end of the required detection range Use the grove on the top of the detector for correct alignment This line of sight corresponds to the upper edge of the detection pattern To limit the detection range a terminating screen can be used to prevent detection of targets beyond the required range Manual
4. uk 9 Adaptive Threshold Discrimination ATD The background noise is constantly averaged and used to adjust the threshold levels for the alarm This special feature reduces the probability of nuisance alarms caused by wind moving vegetation or objects that have a thermal contrast usually weaker than that of a person Each signal exceeding a certain minimum value will activate the ATD and increase the threshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual changes Signals generated by a person moving within the specified speed range however are strong enough for detection Repeated movement of any kind within the field of view is therefore activating the ATD reducing the overall sensitivity This has to be noted particularly when walk testing the following installation The DIP Switch 3 is used to activate or deactivate the ATD Adaptive Threshold Discrimination Switch 3 ATD off on Factory Setting Operation of the VID W03 L100 in this mode is possible but not recommended in outdoor applications as the nuisance alarm rate could increase significantly as a result of turbulences When the unit is walk tested the threshold level will increase as a result of the signal generated by the target it will subsequently decrease exponentially in time after the event To make sure that original sensitivity is reached wait at least for 3 minutes between each cros
5. 8 20 Appendix Specification ecciceccssanwecesvecsceccweasincosezsececanesacunetesvnnwcacenentbanettea ee bananai iaai aiana 9 20 1 Mechanical DIMENSIONS cccccceccsecceeeeeececeeeeeeeeeeeceeeeeeneceeeauseeceeeeneseeeeneeeeeeneceesunesseeeeeeeeeaueseesnaeeeenaeees 9 21 DISCIAIMEE orisni e EEE enrii 10 22 General VV AUN sssini aia Ea AS ENTE EEES 10 23 EIDIN oe E EEEE A E 10 24 Watranty ANIC VC Coarse ss eens ecco onc ys aalteesesaweorieduvevesetersctawans too stawaweuuensindnsnecwencudsevensseosumoccereween 10 2A PaO V ppc ets era clits devs ences a cee lena aerator dvs eres O dlera Sioa dorama pacino ede E AT 10 Ze FACO FNC a che ate teers cee Scr Seneca E artes a et one sateen RET EA A E E EA 10 Manual VID W30 L100_3 2008 doc page 2 10 www norbain co uk 1 Introduction The VID W03 L100 is a highly sensitive Passive Infrared Detector designed for detection outdoors with a narrow curtain shaped differential field of view It incorporates microprocessor controlled signal processing including signal shape analysis adaptive threshold level by feedback of environmental effects temperature compensation and rejection of disturbance signals Sensitivity adjustments are done with DIP Switches for each individual unit in function of the required detection range in order to adapt to the specific needs of an installation 2 Features Gap Free Coverage 4 Meter 13 Feet Mounting Height Advanced Tamper Detection Low Power Consumptio
6. VID W30 L100_3 2008 doc page 3 10 www norbain co uk 7 1 Vertical alignment of VID W03 L100 for a required detection up to nominal range The VID W03 L100 should be aligned vertically so that at a minimum the lower half of a person standing upright at the maximum required range will be within the field of view see Fig 1 below Side view a 4 m 13 ft 1 5 m 5 ft 0 8m 16m 45m Nominal Range 26 ft 52ft 148 ft Fig 1 7 2 Horizontal alignment of VID W03 L100 Horizontal alignment should be done in a way to avoid unwanted signals being generated by miscellaneous objects branches bushes and fences etc that are likely to be moVID by wind see Fig 2 below Movement within the field of view will reduce the sensitivity of the VID W03 L100 by increasing the alarm threshold level and may also lead to unwanted alarms Top view Width Fig 2 8 Sensitivity Settings The settings of the VID W03 L100 are adjusted by means of multiple DIP Switches on the printed circuit board The DIP Switches 1 and 2 are for setting sensitivity depending on the required detection performance If the maximum required range is less than the nominal range of the detector a reduction in the overall sensitivity is recommended to reduce nuisance alarms Overall off off off on co on off Max Range Factory Setting on on Not used Manual VID W30 L100_3 2008 doc page 4 10 www norbain co
7. contrast variation the VID W03 L100 has an internal temperature compensation with maximum sensitivity setting of approximately 30 C where the contrast of a human target is weakest and gradual reduction at higher and lower temperatures When installing a unit the internal temperature may take up to 30 minutes or more to stabilise to the actual external temperature Sufficient time should be given to the VID W03 L100 to reach the correct internal temperature and sensitivity before performing walk tests During the initial period of operation it is strongly recommended that walk tests are repeated under various weather conditions such as high and low temperatures wind fog snow rain etc to obtain comparative data and information on the effects of environmental conditions on detection and nuisance alarm probabilities for this particular site Fine tuning of the detector based on this data by changing the sensitivity settings may optimise the performance 16 Accessories 16 1 Cordless Walk Tester VID WT The cordless walk tester VID WT is an accessory for remotely checking the detector alignment During a walk test it indicates a detection alarm with a beeper and a LED The walk tester VID WT consists of a transmitter VID WT T and a receiver VID WT R For further information regarding the use of the VID WT please refer to chapter 0 16 1 1 Receiver LED Description Power LED indicates power is on and battery o k dims when voltage is lo
8. ducts strictly in accordance with the User Manual and product documents available from Vista Vista is not liable to you or any other person for incidental indirect or consequential loss expense or damages of any kind including without limitation loss of business loss of profits or loss of data arising out of your use of the products Without limiting this general disclaimer the following specific warnings and disclaimers also apply Fitness for Purpose You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own independent assessment of the fitness or suitability of the products for your purpose You acknowledge that you have not relied on any oral or written information representation or advice given by or on behalf of Vista or its representatives Total Liability To the fullest extent permitted by law that any limitation or exclusion cannot apply the total liability of Vista in relation to the products is limited to i in the case of services the cost of having the services supplied again or ii in the case of goods the lowest cost of replacing the goods acquiring equivalent goods or having the goods repaired Indemnification You agree to fully indemnify and hold Vista harmless for any claim cost demand or damage including legal costs on a full indemnity basis incurred or which may be incurred arising from your use of the products Miscellaneous If any provision outli
9. e VID W03 L100 as a detection device is explicitly disclaimed The information in this product manual is based on testing of samples taken at random from production and believes to be representative E amp OE Manual VID W30 L100_3 2008 doc page 7 10 www norbain co uk 19 Appendix Electronic Board and Terminal Block 19 1 Terminal Block Normally closed Output Transistor OC Not used GND Supply voltage 10 5 30 VDC 24V AC B Not used Not used Relay shown in energised non alarm condition 19 2 Dip Switches Sensitivity Function Switches SW1 sw2 Function SW Function 6 Antvandal funcion 8 Notused Manual VID W30 L100_3 2008 doc page 8 10 www norbain co uk 20 Appendix Specification Model VID WOS L100 O O 2 5 4 0 m 8 13 ft Sensor Pyroelectric differential triple channel Front Window PE Filter IR transmissive TE Agusimeni DIP switches wel TAE Heavy duty plastic Colour white Weight app 900 g 2 0 Ibs incl mounting bracket Cable Feeds 2 x M 16 with cable clamp Outer Cable Diameter 4 5 10 mm 0 18 0 40 inch trical Supply Voltage 10 5 30 V DC 24 V AC 15 30 V DC 100 mA Terss 20 C 60 C 4 F 140 F Humidity 95 RH max Sealing IP 64 splash proof Operating Temperature 20 1 Mechanical Dimensions Dim in mm Manual VID W30 L100_3 2008 doc page 9 10 www norbain co uk 21 Disclaim
10. eecuneeubecsvceedscesereestece 5 12 MoUnNUNO UN accra cares ete tee ce scene ceeme stresses E EESE EE SE 5 Dy CED eceeeecauaeamrteene se nee sseec acseessscansantuces 5 tayecenvacewess secs icnsanehcesanecuaesseuwssnescacescsee lt citeceuceansesseaeeaessnatuceseecseas 6 Tm PAGED UG aiceciecuciranie sans sanewndievasevenenaess E A E E 6 15 Internal Temperature Compensation c ccceceeeeeeeeeeneeseneeeeeenseeeeaseeseenseenenseeeeaseesoenseesonseesoensenenes 6 19 PRC COSSO CS egress areca ee cniv eee AA EEA EAEE AEEA EAE EER 6 16 1 Cordless Walk Tester VID WT 0 0 0 0 cc cccccesscesscesseueesseeueeueesueeueeueeeeeeeeuvecevaneuecsuensueeueesueeeeegaescueeaeeas 6 goed Pal nc lelo 1 ee eee en ene ese eee eee ee ene ee 6 1 Ms WANG SOMOS caesarean ioe ge E ans cto dating headend gent ato angst sane Seid nie E ses eam cation ane nasa sianek bana eee 6 16 2 Pole Mount Adapter VID PA cccccccccccccececeeeeeeeeeee ease eeseeeeeeeeeseeeseeeeseeeeseeeeseeessaeeseeeeseueeseeeeseesaneeseneesaees T 17 Maint hante sonnn E E E E 7 18 General Comment on the VID W03 L100 cc ccceeeeeeeeneeeceneeeeneesenseeceseeeeaseceaseeceseeeeaseseaseseasesoanes 7 19 Appendix Electronic Board and Terminal BIOCK cccccsseseeceeneeseesseeeenseesenneeseenseseeeseeseeneesoees 8 191 Terminal BIOCK sissies arsenate aren ae wt ttt ate wa tari sd tude dhe uae A aan 8 1932 DIP OWICIGS a chet iets red bce cicdi cn acide ieee denne ace rsdn era A
11. er The contents of this document are provided on an as is basis No representation or warranty either express or implied is made as to the completeness accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications without obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded 22 General Warning This product must only be installed configured and used strictly in accordance with the General Terms and Conditions User Manual and product documents available from Vista All proper health and safety precautions must be taken during the installation commissioning and maintenance of the product The system should not be connected to a power source until all the components have been installed Proper safety precautions must be taken during tests and maintenance of the products when these are still connected to the power source Failure to do so or tampering with the electronics inside the products can result in an electric shock causing injury or death and may cause equipment damage Vista is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and or failure to take proper precautions 23 Liability You agree to install configure and use the pro
12. n Ideal for Wireless and Solar Applications Wide Power Supply Range Integrated Bracket for Wall Mounting 3 Mounting and Installation The mounting structure should be sold enough to resist significant movement in windy conditions Movement of the VID W03 L100 caused by vibrations or other movements will result in changing fields of view covered by the VID W03 L100 and could cause erratic signals These unwanted signals may lead to an increase in the alarm threshold level which reduces the detection probability or in certain cases can lead to unwanted alarms The stainless steel bracket is ideally suited for wall mounting For pole mounting the VID PA is available the pole mount bracket comes with two strap bands for poles with diameters of 4 16cm For further information please refer to 16 2 It is very important that the cover of the detector is tightened securely Tighten the two screws to the point where it cannot be tightened further with reasonable force There should be less than 1mm gap between the cover and the bottom part of the housing The detectors are fitted with two M16 cable entry points The nut on the cable entry assembly should be tightened to clamp the cable in place If the cable diameter is too small to be held properly insulation tape should be wound around the cable to increase the outside diameter to a suitable size 4 Connecting the VID W03 L100 For the definition of the electronic board and terminal block
13. ned above is found to be invalid or unenforceable by a court of law such invalidity or unenforceability will not affect the remainder which will continue in full force and effect All rights not expressly granted are reserved 24 Warranty and Service 24 1 Factory Service If the unit requires factory service contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service centre If the dealer is not available contact the manufacturer of the unit as detailed below and request a Return Material Authorization number RMA The units serial number must be provided before a RMA number can be issued Units returned to the factory for service must have freight and insurance prepaid and must show the RMA number clearly on all shipping documents The failure symptoms must be clearly described by the operator and enclosed with the unit together with a copy of the original suppliers invoice Failure to comply with these instructions will delay service of the unit and may result in the unit not being accepted by the Repair Centre 24 2 Factory Address Vista Norbain House Eskdale Road Winnersh Triangle Wokingham Berkshire England RG41 5TS www norbain co uk Telephone 44 0 118 944 0123 Fax 44 0 118 944 0999 Manual VID W30 L100_3 2008 doc page 10 10 www norbain co uk
14. sing walk test or disable the ATD function by setting DIP Switch 3 to off The DIP Switch 4 has no function in this model 10 Test When conducting a walk test using the VID WT DIP Switch 5 needs to be set to on On completion switch test to off Switch 5 Test off Factory Setting on The VID WT s transmitter has to be placed within the housing with the detector cover closed and securely tightened The antenna of the transmitter needs to be placed vertically or horizontally in the detector housing 11 Anti Vandal Function AVF The VID W03 L100 is equipped with a sophisticated protection against vandalism mechanism These detectors can sense certain changes to the original their alignment position as set during installation A change of the detector s alignment generates a permanent alarm until the detector s alignment is returned to its original position or until the position is manually reset After the turn on time typically 30 seconds from power on the detector determines and stores its alignment position this will only occur when the detector cover closed After opening and closing the cover with the unit powered on the detector determines its alignment position and after 5 minutes stores this value without the detector being in permanent alarm state The anti vandal function is activated by setting DIP Switch 6 to on Switch 6 AVF off on Factory Setting
15. tate of the art features of the VID W03 L100 it is in the nature of a Passive Infrared Detector that an absolute detection probability and freedom from nuisance alarms cannot be achieVID masking of the VID W03 L100 cannot be excluded Detection is a function of thermal contrast speed and size of a target crossing the detectors field of view Contrast conditions can vary significantly in the course of the day and year Detection depends also on the sensitivity settings the exact aiming and the prevailing weather conditions as well as the nature of the target and background The detection pattern and frequency response of the VID W03 L100 has been optimised for the detection of a human target crossing the field of view in an upright position at speeds in the range of 0 2 5 0 meters second Detection of slow moving targets at long ranges may become difficult under weak contrast conditions Limiting the zone length is strongly recommended to less than the nominal range when human targets moving at the minimum specified speed need to be detected with a high probability of accuracy Animals or crawling people may or may not be detected depending on their size speed contrast and distance from the detector It is therefore strongly recommended to combine the VID W03 L100 with alarm verification such as CCTV or a second system using other physical means of detection e g VMD Any liability for direct or indirect damage resulting from the use of th
16. w Comm LED indicates communication with transmitter is o k Alarm LED lights up as long as alarm is activated 16 1 2 Transmitter Description Power and Communication plug This plug connects to the detector s test socket 2 Power LED LED indicates correct connection and power 3 Antenna To be placed straight in the detector housing Manual VID W30 L100_3 2008 doc page 6 10 www norbain co uk 16 2 Pole Mount Adapter VID PA Pole mounting bracket with two strap bands for poles of 4 16cm 1 6 6 25 diameter Da 17 Maintenance The detector has been designed to be virtually maintenance free but the following precautions are recommended 1 2 3 Visual inspection of the front window for accumulation of dirt on the outer surface or damage to be carried out at approximately 6 monthly intervals Clean the surface with a paper tissue and avoid rubbing dirt into the surface Walk tests for checking the detector alignment and sensitivity settings to ensure optimal performance and reliability Inspection is recommended following extreme conditions such as snow storms sand storms hail etc to make sure that nothing has been damaged and the sensitivity is not reduced by accumulation of snow sand or dirt on the front window Snow or dust in front of the window should be remoVID by hand or by using of a soft instrument 18 General Comment on the VID W03 L100 Despite the advanced design and s

Download Pdf Manuals

image

Related Search

Related Contents

  User`s Manual - Bluetooth, Ethernet to Serial RS  Sony SNCA-PS24/4 power distribution unit PDU  edital - EBRACON  sg halfpar18_v1  USER`S MANUAL  Hot Dry Channel Holding Unit Operators and Service Manual  Philips BRT381  Bard® A Guide for Patients  ST100 Series Profibus-PA Manual - Fluid Components International  