Home

Sentinel XL Full Hood Brochure - multi-page

image

Contents

1. nuclear applications when equipped with three CBRN type filters The blower s integral low battery voltage alarm both audible and visual works with all three types of batteries NIMH Li MnO and alkaline DuraCell is a registered trademark of The Gillette Company 5 TWO EASY TO INSTALL P 100 FILTERS As easy to screw in asa light bulb ILC s high efficiency particulate air HEPA filters remove 99 97 of 0 3 um particles from air passing through them ILC filters are NIOSH approved and designed to pass a 4 hour silica dust test with no drop in required airflow They are rugged lightweight and will not leak or be difficult to clean like some filtration systems The safety plug beneath the chamber can be removed to add a third filter if the blower 15 converted for use in CBRN specific applications 77 b nin 2 23 a ee gt 2 QUICK LOC BELT The Sentinel XL blower and battery pack click into place locking securely to our proprietary belt design Unlike fabric belts that can be grabby our polymeric belt is lightweight smooth easy to grasp and adjusts in two directions with a simple pull on the straps A SIMPLER FLOW SENSOR There are no tips bullet ends or misaligned threading to worry about The Sentinel XL flow meter twists securely into place then turn on the blower to check airflow The meter tube is clear and simple to read
2. SENTINEL XL HP FULL HOOD PAPR SYSTEM THE CHOICE FOR INFECTIOUS DISEASE ENVIRONMENTS Certified APF 1000 A ILC DOVER A creating what s next HELPING TO PROTECT HEALTHCARE PROFESSIONALS IN HOT ZONES AND HOSPITALS THE SENTINEL XL POWERED AIR PURIFYING RESPIRATOR PAPR SYSTEM MODEL 3000 06 helps to provide improved protection from pathogens for healthcare workers and first receivers in the presence of Ebola and other infectious often fatal viruses and diseases It is designed to work in concert with other CDC WHO recommended personal protection equipment including fluid resistant gowns gloves and shoe coverings in accordance with best practice protocols for donning use and doffing The Sentinel XL HP PAPR system comes as a complete kit including one shoulder length double bibbed full hood a flexible breathing hose blower unit with integrated rechargeable NiMH battery a Smart Battery charger flow monitor and adjustable Quick Loc belt plus two P 100 HEPA cartridges and this user literature all in a durable zippered duffle bag ready for immediate deployment Read on to learn all of the advantages of the Sentinel XL HP PAPR system 3 ONE HOOD MANY BENEFITS The Sentinel XL HP head cover 15 a fully enclosed latex free hood with an integrated antimicrobial headband eliminating the need to buy and stock different size hoods Its flexible interior prof
3. partner with you to custom create a product or technology for your precise application or need Let us create what s next for you Learn more about us at www ilcdover com ILC DOVER creating what s next MKT 0037 Rev D
4. Positive air pressure keeps the sensor indicator floating in the safety zone ONE FLEXIBLE BREATHING TUBE The Sentinel XL breathing tube is a clear ribbed design that reliably links the hood and blower system 5 durable design resists nicks and cuts Epoxy at both ends of the tube ensures a strong seal and sure handed threading top and bottom The tube is easy to use and replace if exposed to Ebola or other lethal viruses or diseases Replacement tubes are sold in packs of five 6 SENTINEL XL HP SYSTEM TRAINING TO HELP BETTER PROTECT YOUR PERSONNEL While many hospitals and healthcare systems offer CDC and WHO recommended training on how to properly and safely put on operate and remove PAPRs ILC can also send a highly skilled instructor to your location for Sentinel XL HP specific training sessions This can help to ensure that your physicians and nurses EMTs first receivers or other healthcare personnel are competent and confident in all procedures and safeguards Please review the guidelines as released by the CDC and WHO then visit their respective websites for the most current data or instructions Basic Sentinel XL HP system training guidelines may be found in the video section of our website www ILCDover com REPLACEMENTS AND SPARES The Sentinel XL HP PAPR system comes fully equipped to protect one individual Additional hoods extra batteries breathing tubes and HEPA filters may be ordered separate
5. ations simply by changing hood hose and filter cartridges Unique lay flat butyl hood assembly 3 CBRN filter cartridges CBRN Cap 2 User s Manual Designed to hold blower battery hood charger hose and up to three filter cartridges Blower can be charged while backpack Material Polyester and nylon One Moonwalker Road Frederica DE USA 19446 2080 302 335 3911 800 631 9567 customer_service ilcdover com www ilcdover com ABOUT ILC DOVER Founded in 1947 ILC Dover specializes in products and technologies that provide unparalleled protection for people and equipment in hostile environments We have been the sole designer and manufacturer of NASA space suits since manned Apollo missions began in 1967 And creating what s next for future missions to Mars We are also leveraging these competencies in materials soft goods and film based solutions to protect humans against infectious or deadly diseases and chemical biological radiological and nuclear contamination In the pharmaceutical industry we provide powder transfer packaging liners and containment systems FDA compliant films equipment enclosures and PAPRs to protect workers against active pharmacological agents Additionally we are world leaders In engineered inflatable and lighter than air products for use by the military and homeland security plus products for flood smoke and fire protection and infrastructure security ILC Dover s design engineers can also
6. bout power draining recharging ALKALINE For the ultimate in increased readiness choose 5 innovative alkaline battery pack accessory option Ideal as an NiMH battery backup or for remote locations or when available generator power is tapped out this unique solution comes with a 5 pack of DuraCell D cell batteries its own adapter and backing plate and runs the blower for up to 10 hours When the D cells run low just replace them with fresh batteries No waiting no recharging And only ILC offers this option All three Sentinel battery packs snap into place in the blower housing to form an integrated self contained system This exclusive ILC Dover design offers clear advantages over competitive PAPR systems that require the battery pack to be connected to the blower with an external cord that adds weight and complexity and poses a risk of snagging on medical equipment patient beds or door handles A BLOWER DESIGNED FOR LONG SERVICE LIFE The Sentinel XL dual chamber blower is encased in a high impact nylon shell with a rugged inner polycarbonate chamber It also features rounded surfaces to resist snagging plus a robust motor design for quieter operation and longer life The blower delivers 8 5 scfm of filtered ambient air 33 higher flow than required by NIOSH Air is fed through two NIOSH approved screw in type HEPA cartridge filters The blower can also be converted for use In chemical biological radiation
7. ile also ensures a contoured fit around the chin and face Forward and peripheral vision Is excellent through the rugged sealed clear plastic face shield A ribbed breathing tube threads securely into the back The product is NIOSH approved TC 21C 0814 and the hood fabric meets ASTM Standards 1670 and 1671 The belt mounted blower delivers purified ambient air into the hood at 8 5 scfm with 99 97 filtration efficiency creating positive air pressure inside which helps to support it The hood also features two bibs an Inner one that tucks in under the wearer s fluid resistant gown through the neck opening plus an outer bib that drapes over the chest shoulders and back allowing free movement It is recommended that the hood be safely disposed of rather than decontaminated after exposure to Ebola or other deadly viruses or diseases A CHOICE OF THREE INTEGRAL BATTERY PACKS NiMH The Sentinel XL HP PAPR system comes standard equipped with a rechargeable nickel metal hydride battery and Smart Battery charger The blower runs up to 8 hours ona single charge and emits an audible and visual warning if battery power gets low The battery recharges in 5 hours A lithium manganese dioxide battery is also available It offers up to 10 hours of operation but is not rechargeable Its advantage lies in its 10 year shelf life so may be left in storage until needed ready for any emergency without worries a
8. ly Hoods in particular should be properly discarded after one time use In the presence of Ebola or other deadly diseases For more information about the availability of replacement or spare components please contact ILC Dover at 302 325 3911 x 506 or 800 631 9567 or send an email to customer_service ilcdover com 7 SENTINEL XL HP PAPR KEY FEATURES e Shoulder length double bibbed hood provides full coverage and integrates easily with gowns suits and other PPE e Single size hood eliminates the need to purchase and stock multiple sizes e No fit testing required e Audible visible low voltage alarm provides peace of mind e Three battery options including a unique alkaline battery adapter provide flexibility and readiness in a broad range of use scenarios e Threaded interface filters and breathing tube connections are reliable and easy to use Lightweight and durable loose fitting PAPR designed to protect against airborne infectious diseases W SYSTEM COMPONENTS e Blower e Choice of full hood shown or white or premium head cover e 2 HEPA filters and plug e Rechargeable NiMH battery pack standard e Fast battery charger e Flow meter Quick Loc belt e 33 long HP breathing hose e Non rechargeable LiMnO battery pack optional e Alkaline D cell battery adapter optional e Backpack optional 8 SENTINEL XL HP PAPR EASY CONVERSION System can be converted for CBRN applic