Home

Pacific - powerbridge.cz

image

Contents

1. grams Dam S A Operation at ZONE 3 Display of mechanical and 20 C to 60 electrical values and the associated Humidity measurements 95 to 45 70 to 50 C 50 to 60 C sore and MUS sue The TELYS can now be fitted with 5 language options display and remote control numerous languages options allowing the generating Option to connect set to be actively monitored and up to 5 additional managed for increased safety I O modules 4 inputs 6 outputs b BEEN KERYS TACTIL The KERYS tactil command and control unit has been designed to fulfil the specific requirements of professionals in terms of managing and monitoring generating sets It therefore offers a wide range of functions This control unit is fitted as standard to all generating sets designed to be used for coupling and is offered as an option across the rest of our range The KERYS tactil can be built into the central console fitted directly on the generating set or a separate cabinet to fulfil all the requirements for low and high output power plants AUTOMATIC CONTROLLER DEDICATED TO GENERATING SET APPLICATIONS GRAPHS AND ARCHIVING OF ELECTRICAL AND Choice of a range of basic standard configurations MECHANICAL PARAMETERS e Additional logics can be added without any external tools Adjustable sampling configurable triggering criteria e Library of functional modules COMPLIANCE WI
2. Separate fuel tank on 500 container Separate fuel tank on 1000 container Retention container level alarm Im h pump auto kit 1 Im h pump auto kit 2 4m3 h pump auto kit 2 Diesel separator pre filter User manual and commissioning guide paper version French English or Spanish User manual and commissioning guide paper version French English or Spanish 3 User manual and commissioning guide CD version French English or Spanish Engine parts catalogue paper version English Engine parts catalogue CD version English Engine repair and workshop manual paper version English Engine repair and workshop manual CD version English GENSERVICE replacement parts 16 PACIFIC Il EN 02 20 AL Ol AL 06 AL 07 AL 08 AL 09 AL 10 QU AO 001 AD21 and AD 22 Battery isolating switch User manual and commissioning guide 1 Synchronising CT coupling not required for Mics KERYS 2 Outdoor ambient temperature reduce by approximately 7 C 3 Additional copy ww OHZ 6 CONTENERGY The CONTENERGY concept offers a range of soundproof containers featuring a multitude of options Thanks to their standard dimensions CONTENERGY containers are easy to transport and once on site very simple to install ve would recommend that you install them outside the building on a concrete floor plate fitted with a tunnel for the cables and pipes Highly economical thanks to its
3. cooling system integrated sound traps and silencers the CONTENERGY concept is completely self contained with a fuel capacity which enables it to operate immediately without connection to an additional tank SDMO understands the many factors that have an influence on your equipments operation That is why our containers are designed to withstand harsh climate conditions Whether your equipment needs to operate in extreme cold or tropical environments let us know your requirements we are sure to have the solution youre looking for Trailers compliant with international standards are also available allowing you to transform your generating set into a mobile unit please contact us The CONTENERGY design means that one simple connection is all it takes to get your power plant up and running BEEN oO0nuz 60HZ Conternergy CONTENERGY ML CONTENERGY ISO The dimensions of CONTENERGY ISO containers comply with CSC certification They have been specially designed to withstand significant loads and pressures during transport without incurring damage and can be shipped without any special constraints They are available in two sizes 20 and 40 feet High Cube P Al S CONTENERGY CIR P CIR type containers specially designed with mobile and rental applications mind This highly compact model has a very low sound level and features an optional high volume tank giving i
4. to offer you performance products from a large range which meets all the requirements of different markets This range comprises 3 main categories Standard products 2027 Rove ALSO e 2110 efl s CO DS Expertise and Services Ene Solio Related products 205 1020 5 National coverage international presence think globally act locally In order that SOMO can continue to grow and expand into new markets it relies On Market logic for greater reactivity The production plants in Brest are organised according to product lines relating to the product range offered distribution network present in over 150 countries 8 overseas subsidiaries sales offices 3 regional HOs France The reactivity of the company is based on its 5 storage platforms which in co operation with the subsidiaries constitute an efficient means of operating The links forged with the Kolher group have strengthened SDMOS standing amongst its customers through a strategy of synergistic installations a production site for Portable Power generating sets and for Power Products with lower power a production site for Power Products Rental Power and a production site used for the production of special Power Solutions applications This overall synergy between industria
5. 1 43 908 434 FAX 55 11 43 908 434 SPAIN SDMO INDUSTRIES IBERICA TEL 34 902 30 56 56 FAX 34 93 580 31 36 US SDMO GENERATING SETS TEL 1 305 0012 PAA ti 203 00377 B UK SDMO ENERGY LTD A Oe oo NIGERIA SDMO LAGOS TEL 234 0 80 56 66 64 44 FAX 33 0 1 72 27 55 62 GERMANY SDMO GMBH TEL FAX 49 0 6332 97 150 Offices SOUTH AFRICA SDMO JOHANNESBURG TEL 33 0 631 594 701 FAX 33 0 172 276 151 ALGERIA SDMO ALGER TEL 213 0 21 68 12 12 FAX 213 0 21 68 14 14 DUBAI SDMO MIDDLE EAST TEL 971 50 51 496 83 FAX 33 0 1 72 27 55 52 RUSSIA SDMO MOSCOW TEL 7 926 838 05 34 FAX 33 0 1 72 27 55 48 ISO 9001 SHORT VERE SDMO industries Implantation en France Non contractual document In accordance with our product quality improvement policy SDMO Industries reserves the right to modify without prior notice any specifications published in this catalogue Photo credit SDMO Guillaume Team SDMO is a registered trademark of SDMO Industries 5268 10 08 L Ve Cj com 02 43 52 12 00 www cj com fr
6. PPR PA DO GB 01 50608 127 5 2200kKVA 1091kWe 2000kWe Global Power Solution A powerful response SDMO is recognised as one of the top manufacturers of generating sets in the world gt gt its energy into designing a range which ts both highly competitive and high performance the largest range available on the market As a response to the increasingly precise nature of your energy requirements which relate directly to the special traits of your particular industry SDMO is devoting the majority of its resources to the continuous improvement of its range and services iste Westie a strategy TOcussed on a 916618 200 professionalism which provides you with a reliable source of energy complying with the strictest of standards The pioneering mindset of its teams and the mastery and flexibility of its production methods mean that SDMO is constantly innovating The proximity of its distribution network and dynamism of its customer services policy enable SDMO to be a powerful force and provide the basis of the company s values SDMO the source of energy for your comfort and safety SDMO providing the energy that links mankind www sdmo com ie es ou UL Whether you require emergency power to be able to cope with potential power cuts e g hospitals shopping centres or continuous power when conventional electrical grids are faulty power plants SDMO will be able
7. TH INTERNATIONAL STANDARDS FAULT FINDING HELP The KERYS tactil has undergone very stringent tests in e Validation of operation by simulation independent laboratories climatic tests Display of the status of variables electromagnetic compatibility tests vibration tests etc e Breakdown guide with keyword search It is CE compliant ASSISTANCE AND MAINTENANCE Emails sent automatically for maintenance requests and for the appearance of alarms or faults e Log of operations carried out maintenance or breakdown LOAD IMPACTS Improvement of generating set performance during application of a significant load n MMI INTERFACE The man machine interface is available with a colour screen and a 7 inch touch panel The MMI module is equipped with all the keys required to ensure the generating set can be controlled navigator and an alphanumeric keypad Control keypad Display screen with display LEDs ing Detailed colour display Touch screen Dimensions 154 x 86 mm Manual mode selection Stop mode selection Automatic mode selection Generating set circuit breaker open close Test activation deactivation Alphanumeric keypad Grid circuit breaker For setting parameters open close navigation and direct ACCESS to screens Horn off Clear faults Arrow keys with op
8. cessories O x EN 21 FD 01 2 Air filter with interchangeable cartridge As standard Not possible Several possible options contact us Option code Free option Basic and options 4 stroke water cooled diesel engine Electronic control device Standard air filter Air filter with interchangeable cartridge 220 240 V preheating resistance no control 23 single bearing alternator T class H insulation class H H Anti condensation resistor Reinforced insulation Reinforced insulation and finish Stator PTC sensor Bearing PTC sensor Stator PT 100 sensor Bearing PT 100 sensor Synchronising CT coupling 3 function regulator Oversized alternator CE compliance of the control unit Mechanically welded base frame with antivibration dampers Supplied in colour RAL 9005 5007 black blue delivered in shrink wrap film Supplied with oil and coolant 30 C Automatic oil top up with tank Oil drainage pump Radiator core temperature of 50 C max with mechanical fan Supplied without coolant Protective grille for fan and rotating parts Protective grille for radiator core Stainless steel compensators 9 dB A silencer supplied separately 29 dB A silencer supplied separately 40 dB A silencer supplied separately 24 V charging alternator and starter motor Batteries with cables and battery support bracket No battery and battery support bracket Battery isolating switch Generating set without fuel tank
9. eration LEDs nirol uni e Single generating set or as part of power plant e Operation in HT high tension or LT low tension Normal Emergency operation Operation in permanent or temporary grid coupling without cut out e Upon return to grid power e During peak shaving During trials tests inverted emergency operation e Power production unit e Cogeneration MEASUREMENTS AND DISPLAYS Mechanical e Pressures and levels depending on engine configuration Electrical e Voltages Currents e Frequency and power Power factor Outputs Mechanical and electrical metering SAFETY FEATURES Mechanical Electrical pea Currents e Alarms Voltages Engine safety Outputs Special customer features Freqg _ e Micro cut outs EH ajir lectrimg Usriables REG E FERD 3 Graph display GENERATING SET AUTOMATIC CONTROL COMMUNICATION e Built in web server e User friendly man machine interface 5 basic languages French English Spanish Portuguese German one of which is interchangeable please consult us existen PEOR Dialogue with all engines equipped with a built in ECU e RS 485 port for Modbus e RS Z232 Option of PSTN communication Public Switched Telephone Network CONTROLS Mechanical SOS Synchronisation Coupling e Distribution or setting of grid or
10. generating set active power 13 Wattmetric programming Electrical e Voltage Voltage equalising e Distribution or setting of grid or generating set reactive power e Adjustment of the grid or generating set power factor cos Phi Other physical values Synchro en cours 4 Mechanical measurements screen For more detailed information refer to the KERYS documentation or contact your SDMO sales representative ower modules Each generating set may be supplied with a protection unit This unit is mounted on the chassis with connection cables to the alternator It is located on the right hand side of the generating set Sele Rating 1250A 1600 2000A 2500 A 3600 A With manual control the front Fixed 3 pole power circuit breaker Fixed 4 pole power circuit breaker Oo o O Motorised control option With 3 or 4 pole open circuit breaker only L 9 o amp O Auxiliary unit option 4 L9 i 2 O Power connection bus bars E Remote control terminal block Protection index IP 207 a M 68 68 3 3 65 65 DIMENSIONS height 1883 1883 1883 1883 1883 with connection unit width mm 683 683 365 65 65 on upper section depth mm 365 3 3 365 1 motorised control includes a closure solenoid valve a shunt trip Standard co
11. he transfer of a main source to a replacement source is crucial for the running of your installations Straightforward and easy to use the special feature of this module is that it is automatically configured when voltage is provided from the grid side By simply pressing the AUTO key the following parameters are configured grid voltage voltage min max thresholds type of use frequency min max thresholds Electronic switching of the power source means that the unit can be continuously self supplied Screen Confirm key Navigation and with integrated backlighting with selection 2 lines of 16 characters keys used for scrolling through the different electrical value display screens and for configuring all the Rotophase LED Indicates the phase rotation direction module parameters to the customer specifications Source Status LED Three colour LED showing Test used to simulate generating set starting including the possibility of a changeover sequence the status of the source Position LED LED showing the closed position of the switch or changeover switch Operating keys Key 1 Forced source operation Auto key automatic module Key 2 Forced source 2 operation configuration for automatic operation Reset key clears the fault display during mains cut off or voltage drop TSIMODULE 2 lines on the screen enabling simultaneous display of the voltage on the grid side and the generating set side The same app
12. ign inspired by the NEXYS has reduced the number of buttons to offer you simplicity when operating your generating set It also offers new functions Integrated maintenance monitoring programme on screen display of required maintenance operations On board service tool to guide the user when a warning or fault is detected Viewing and remote control functions with option to send b an E mail text message or fax in the event of a warning or a fault Alarm LEDs Emergency 7 075715 refe e S under stop push sealed cover Telys SDMO s flagship product integrates new options and offers improved ergonomics more user friendly design It is even more straightforward with the emphasis on communication USB connections PC connections control software and remote Fault LEDs TEYS Card tropicalisation possible to compensate for extremely humid conditions b Compliance with numerous legal and regulatory requirements EC Screen with contrast which adjusts to all types of light b As an option Generating set start button Te Save MED Display screen composed of 4 zones ZONE 1 Operation mode generating set running auto manual ZONE 2 Display of functions via ESCAPE button TELYS Generating set sto button Menu access button Scrolling and validation wheel TELYS FIGURE
13. il and an AC motor O Option 2 The auxiliary unit option is mounted above the main unit It is used for the power connections of generating set auxiliaries e g air cooler output fuel pump unit output A connection unit without air cooler unit A connection unit with air cooler unit with integrated air cooler unit on the lower section if necessary INTRODUCTION NORMAL EMERGENCY SWITCH SDMO provides a complete range of separate Normal Emergency switches There are a large number of benefits to our technology both in terms of cost and of ease of installation The design of the control units and boxes enables even cables with large cross sections to be easily connected The front panel of the unit no longer opens on just one side like a conventional control 800A 1000A 1600A 2000A 2500 e a Switches Heights mm 1000 1000 1000 18002 18002 wean mm 80 s 900 1000 1000 500 800 800 3150A Voltage Dimensions unit but on three sides allowing total access to Depth mm 500 800 all the connections for the power equipment and terminal blocks All our control units are either 1 Integrated into a floor mounted control box 2 On a base plate h 200 mm i e control box of three pole or four pole height 1600 200 INTRODUCTION Both innovative and original in design the TSI is perfectly suited to applications where t
14. l teams and sales and marketing departments reinforces the position of SDMO prescription reactivity presence on the major markets Generating sets in the PACIFIC range feature a winning combination robust design and ease of use 90Hz RANGE T1400 T1650C 6017 range T1800U T2000U Generating set specifications 480 277 V gp 3 Engine specifications Alternator Open Version 5 RANGE gp 3 85282 g P P US Cons SETS PRP Esp 3 4U h m mds Dimension g TI200U 1091 1200 Wel S09 501 7 4 33 2 00 2 37 2701 Era sa p me cem p e pe pes nen ws om s sem pe om om 299 T2000U 1818 2000 357 S16R PTAAZ 1 Also available the following voltages 440 V 254 V 2 ISO 8528 powers specified in compliance with the legislation in force 3 PRP main power available continuously under variable load for an unlimited number of hours annually in accordance with ISO 8528 1 16 18 05 87 512M60 5 50 2 29 2 58 14371 4 ESP Emergency Standby Power available for supplying emergency power in variable load applications accordance with ISO 8528 1 no overload available for this service 5 The dimensions and weights apply to a generating set specified in the price list without options 6 Dry weight without fuel BASIC AND OPTIONS engine generating set cooling starting ac
15. lies to the frequency 6 LEDs provide instantaneous information on the position status of both of the two 2 sources along with any alarms and faults which arise The TSI also offers 3 configurable inputs and 2 outputs as an option ADDITIONAL SPECIFICATIONS please consult us Communication In addition to a wire connection enabling dry contact remote starting with all SDMO command control units TELYS KERYS the module also has a CAN bus which enables it to communicate with the KERYS This connection allows all information relating to the grid and the starting order following a variation in voltage to be sent to the KERYS French Offices WEST SDMO BREST TEL 02 98 41 13 48 FAX 02 98 41 13 57 CENIRAL WEST SDMO CHOLET TEL 02 41 75 96 70 FAX 02 41 75 96 71 PARIS NORTHERN NORMANDY SDMO GENNEVILLIERS TEL 01 41 88 38 00 FAX 01 41 88 38 37 EAST SDMO METZ TEL 03 87 37 88 50 FAX 03 87 37 88 59 SOUTH EAST SDMO VALENCE TEL 04 75 81 31 00 FAX 04 75 81 31 10 SDMO AIX TEL 04 42 52 51 60 FAX 04 42 52 51 6l SOUTH WEST SDMO TOULOUSE TEL 05 61 24 75 75 FAX 05 61 247579 SDMO SDMO Industries 12 bis rue de la villeneuve CS 92 848 29 228 Brest Cedex 2 France TE 0 Wwww sdmo com Subsidiaries ARGENTINA SDMO ARGENTINA S A TEL 54 114 836 35 11 FAX 54 114 836 35 16 BELGIUM SDMO NV SA TEL 32 3 646 04 15 FAX 32 3 646 06 25 BRAZIL SDMO DO BRAZIL TEL 55 1
16. s control unit CM 40 MICS KERYS control unit CA 600 5 Length mm 6058 2 Width 2438 5 Height mm 2896 2896 2896 As standard X Not possible Free option BEEN SOHZ 60HZ Wu f Three control units are available in our 650 to 3000 kVA range the M80 the TELYS previous pages and the KERYS Your control unit can be chosen according to your equipment type and perfectly adapted to suit your needs with the options available This modularity is made even easier by the fact that each optional peripheral device air cooler daily service tank oil top up etc Nas its own protection For power plants separate control boxes may be used in place of the control units please do not hesitate to contact us The M80 control unit has a dual functionality It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility with displays giving a global view of your generating set s basic parameters Coolant temperature Tachometer Oil pressure Emergency stop button i A pi 78 e HW Ko 1 SDMO E MDP 1 e E A c a zi t P BASIC TERMINAL BLOCK Measurements Tachomater Stmm _ _ X 0 Oil pressure gauge X Engine parameters Coolant temperature indicator Miscellaneous X Not available O Options As standard operation Its des
17. t up to 10 hours of NI autonom To protect the environ y ment our containers may This model is available as a 20 feet High Cube be fitted with an optional retention container to hold all engine fluids Our containers comply with all current standards and regulations governing these products including ISO 668 NF90 005 NF ISO 1496 1 ISO 8323 Tom Silent 1275kVA 1540kVA de x 2 i 15040 ah5 1700KVA 2100kVA standard containers EQUIPMENT _ SILENT SUPER SILENT Basemember 0 08 0 0 0 0 00 0 0 0 0t 000000 Starter motor 24 V charging alternator ee eee id 8 Batteries filled with electrolyte SO 001 Standard air fiter _ ot Oldrimagepump Type of soundproofing 55 High performance integrated 30 dB A silencer 5 Floor Bulb plate Numberofdoors 2 220 3 Galvanised air outlet rain grille Safety lighting and shutoff valve Cr 007 Exhaust outlet on bracket CT O11 S RAL 9010 white painted finish for container 2 Special colour from list CT O16 Power cable outlet on lower section IOS Retention container under container assembly CT O14 500 baseframefueltank PX Tankoncontainer 500 XP x Tank on container 2000 CTOI7 a External terminal block CT O18 pump auto kit 1 008 Im h pump auto kit 2 x pump auto kit 2 x ou CE compliance of the control unit eo do tm ee 55 MICS Tely