Butterfly Valve Documentation

image

Contents

1. 1 1 4 20 1 1 8 24 32 1 7 8 29 1 2 1 3 8 20 1 1 4 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 119 O50904 02 12 Subject to change Belimo Aircontrols USA Inc LUG BODY HEX HEAD MACHINE BOLTS LUG BODY STUDS and NUTS Bolt lengths A amp B are from face of valve body to minimum depth in lug Flange amp gasket thickness must be added to calculate minimum bolt length Special length required for tapped blind holes on either side of the valve shaft at the top and bottom ends of the valve body FLANGE BOLTING RECOMMENDATIONS Lug Valves 2 24 ANSI 250 300 Bolt Pattern BOLT ENGAGEMENT IN VALVE STUDS amp NUTS MACHINE BOLTS Valve Size Thread Size A QTY LENGTH B QTY LENGTH C QTY LENGTH D QTY LENGTH F QTY LENGTH G QTY LENGTH 2 5 8 11 8 94 8 57 8 2 25 8 2 62 8 1 50 8 2 00 2 1 2 5 8 11 8 97 8 67 8 2 75 8 3 00 8 1 75 8 2 00 3 3 4 10 8 1 03 8 82 8 3 00 8 3 00 8 2 12 8 2 00 4 3 4 10 8 1 19 8 87 8 3 50 8 3 25 8 2 50 8 2 00 5 3 4 10 8 1 22 8 79 8 5 25 8 3 62 8 2 25 8 2 75 6 3 4 10 12 1 30 12 92 12 3 75 12 3 50 12 2 75 12 2 25 8 7 8 9 12 1 70 12 1 12 12 4 50 12 4 00 12 3 25 12 2 75 10 1 8 16 1 86 16 1 30 16 5 00 16 4 50 16 3 25 16 3 12 12 1 1 8 8 16 2 05 16 1 47 16 5
2. 146 5 00 6 88 6 88 17 00 5 50 4 5 8 11 UNC 285 F780 150SHP 3 228 5 50 7 56 7 56 17 50 6 00 4 5 8 11 UNC 285 F750 150SHP 2 102 4 50 6 38 6 38 22 25 4 75 4 5 8 11 UNC SY2 285 F765 150SHP 2 146 5 00 6 88 6 88 22 75 5 50 4 5 8 11 UNC 285 F780 150SHP 3 228 5 50 7 56 7 56 23 00 6 00 4 5 8 11 UNC 285 F7100 150SHP 4 451 6 50 8 63 8 63 23 75 7 50 8 5 8 11 UNC SY3 285 F7125 150SHP 5 714 7 50 9 75 9 75 24 25 8 50 8 3 4 10 UNC 285 F7150 150SHP 6 1103 8 00 10 25 10 25 24 75 9 50 8 3 4 10 UNC 285 F7200 150SHP 8 2064 9 00 11 50 11 50 32 00 11 75 8 3 4 10 UNC SY4 150 F7250 150SHP 10 3517 11 00 13 81 13 81 33 00 14 25 12 7 8 9 UNC SY4 150 SY5 285 F7300 150SHP 12 4837 12 00 15 81 15 81 35 00 17 00 12 7 8 9 UNC SY5 150 SY7 285 F7350 150SHP 14 6857 14 00 17 62 17 62 36 00 18 75 12 1 8 UNC SY7 285 F7400 150SHP 16 9287 15 00 19 00 19 00 37 50 21 25 16 1 8 UNC SY7 150 SY9 285 F7450 150SHP 18 11400 16 50 21 00 21 00 42 25 22 75 16 1 1 8 8 UNC SY8 150 SY10 285 F7500 150SHP 20 14420 18 00 23 00 23 00 49 50 25 00 20 1 1 8 8 UNC SY9 150 SY11 285 F7600 150SHP 24 22050 22 00 28 06 28 06 56 25 29 50 20 1 1 4 8 UNC SY12 150 F7 Series 3 Way ANSI Class 150 Butter y Valve Rein
3. 200 F6250HD 10 5340 2047 2 67 12 00 15 00 30 00 14 25 12 7 8 9 UNC 200 F6300HD 12 8250 3062 3 01 12 00 15 00 32 00 17 00 12 7 8 9 UNC 200 F6350HD 14 11917 4568 3 02 12 00 15 00 33 00 18 75 12 1 8 UNC SY5 150 F6400HD 16 16388 6282 4 01 12 00 15 00 34 50 21 25 16 1 8 UNC SY6 150 F6450HD 18 21705 8320 4 50 14 00 21 00 39 25 22 75 16 1 1 8 7 UNC SY8 150 F6500HD 20 27908 10698 5 00 14 00 21 00 41 50 25 00 20 1 1 8 7 UNC 150 F6600HD 24 43116 16528 6 07 14 00 22 00 53 25 29 50 20 1 1 4 7 UNC SY11 150 F6750HD 30 73426 28146 6 51 14 00 22 00 57 50 36 00 28 1 1 4 7 UNC SY12 150 Dimension A is compressed add 125 for relaxed state SY6 and larger available in 110 220 VAC versions only AF AM and GM maximum actuator ambient temperature is 122 F SY maximum actuator ambient temperature is 150 F Application Notes 1 Valves are rated at 200 psi differential pressure in the closed position SY 150 psi 14 2 Valves are furnished with lugs tapped for use with ANSI Class 125 150 anges Installation anges and hardware are not included 3 2 way assemblies are furnished assembled and tested ready for installation 4 Dimension D allows for actuator removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data
4. Actuators may be connected in parallel if not mechanically mounted to the same shaft Power consumption and input impedance must be observed 4 Position feedback cannot be used with Triac sink controller The actuator internal common reference is not compatible 5 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 8 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 9 For triac sink the common connection from the actuator must be connected to the hot connection of the controller Meets UL requirements without the need of an electrical ground connection WARNING Live Electrical Components G During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury Electrical Installation Wiring diagram Y U 1 3 2 5 T Cable colors 1 black 2 red 3 white 5 orange Cable lengths Y U 1 3 2 5 T A C L1 L2 Ltot A Actuator C Control unit L1 Belimo connecting cable 1 m 4 x 0 75 mm2 L2 Customer
5. GM Series SY Series 146 80 2 F665 150SHP 228 125 3 F680 150SHP 451 248 4 F6100 150SHP 714 392 5 F6125 150SHP 1103 607 6 F6150 150SHP 2064 1135 8 F6200 150SHP 3517 1934 10 F6250 150SHP 4837 2660 12 F6300 150SHP 6857 3592 14 F6350 150SHP 9287 4865 16 F6400 150SHP 11500 3270 18 F6450 150SHP 14420 7590 20 F6500 150SHP 22050 11550 24 F6600 150SHP 34388 18012 30 F6750 150SHP MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F650 150SHP 2 102 1 50 6 10 14 26 39 56 77 99 102 F665 150SHP 2 146 2 20 8 80 20 37 55 80 110 142 146 F680 150SHP 3 228 3 40 14 32 57 87 125 171 221 228 F6100 150SHP 4 451 6 80 27 63 114 171 248 338 437 451 F6125 150SHP 5 714 11 43 100 180 271 393 536 693 714 F6150 150SHP 6 1103 17 66 154 278 419 607 827 1070 1103 F6200 150SHP 8 2064 31 124 289 520 784 1135 1548 2002 2064 F6250 150SHP 10 3517 53 211 492 886 1336 1934 2638 3411 3517 F6300 150SHP 12 4837 73 290 677 1219 1838 2660 3628 4692 4837 F6350 150SHP 14 6857 103 411 960 1728 2606 3771 5143 6651 6857 F6400 150SHP 16 9287 139 557 1300 2340 3529 5108 6965 9008 9287 F6450 150SHP 18 11400 171 684 1596 2873 4332 6270 8550 11058 11400 F6500 15
6. Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stainless steel RPTFE 17 4 PH stainless PTFE glass backed PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 150 Close off pressure 285 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight Bubble tight shut off to ANSI Class 150 Standards Long stem design allows for 2 insulation minimum Valve Face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI B16 5 Flanges Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Dead End Service Follow all described pre installation and installation procedures Valves are capable of bubble tight dead end closure with either the upstream or downstream ange removed Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN 2 way Spring Non Spring 102 56 2 F650 150SHP AF Series
7. NC NC NO COM COM COM SWITCH 2 SWITCH 3 SWITCH 1 M2 OPT HEATER t CAPACITOR M M3 THERMAL OVERLOAD AUTOMATIC RESET M1 GROUNDING GREEN 120VAC MAINS POWER LINE SENSE A6 A5 A1 A7 ACTUATOR DRIVE SWITCHING WAVEFORM GENERATOR CONTROL LOGIC NOTE FULLY OPEN WITH ACTUATOR SWITCHES SHOWN TERMINAL 7 amp MUST BE WIRED ALSO POWERS OTHER ELECTRONICS NOTE SY ACTUATOR 120VAC Sequence of Operation 2 Position Control NSV SY Battery Back Up System For Belimo SY Series Electric Actuators 2 Position or Modulating The back up system is wired in series between the mains power and the actuator Under normal operation power supplied to TB1 H amp N terminals will illuminate the green LINE IN indicator light and provide charging voltage to the battery system While under mains power the eld select switch or form A contacts are enabled to control the positioning of the actuator The end user can install a center off switch for 3 point oating control a SPDT toggle switch for 2 position control or interface through an automation system s form A contacts Any method of operation will not affect the back up unit s operation While under mains power the blue BAT CHARGING indicator light is illuminated while the yellow B U POWER indicator light remains off While under mains power the position of the FAIL POSITION
8. O50904 02 12 Subject to change Belimo Aircontrols USA Inc NSV SY Battery Back Up System For Belimo SY Series Electric Actuators 2 Position or Modulating Sequence of Operation Modulating Control Note This Model requires modi cation to SY MFT Model interface wiring inside the SY actuator The back up system is wired in series between the mains power and the actuator Under normal operation power supplied to TB1 H amp N terminals will illuminate the green LINE IN indicator light and provide charging voltage to the battery system While mains power is present the SY drive logic interface card is enabled and provides proportional positioning of the SY actuator in response to incoming signals from customer supplied eld automation devices While under mains power the blue BAT CHARGING indicator light is illuminated while the yellow B U POWER indicator light remains off While under mains power the position of the FAIL POSITION SELECT switch is irrelevant Power is supplied through the interface cabinet and the actuator heater is enabled All internal actuator controls are otherwise not affected by the backup system All movement of the actuator is controlled by the automation control system No current is being drawn from the battery system during this mode of operation When the mains power is lost charging power is no longer supplied to the battery system and the green LINE IN indicator light is t
9. 500 F6500HD 43116 16528 24 600 F6600HD 73426 28146 30 750 F6750HD MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F650HD 2 115 06 3 7 15 27 44 70 105 115 F665HD 2 1 2 196 10 6 12 25 45 75 119 178 196 F680HD 3 302 20 9 18 39 70 116 183 275 302 F6100HD 4 600 30 17 36 78 139 230 364 546 600 F6125HD 5 1022 50 29 61 133 237 392 620 930 1022 F6150HD 6 1579 80 45 95 205 366 605 958 1437 1579 F6200HD 8 3136 2 89 188 408 727 1202 1903 2854 3136 F6250HD 10 5340 3 151 320 694 1237 2047 3240 4859 5340 F6300HD 12 8250 4 234 495 1072 1911 3062 5005 7507 8250 F6350HD 14 11917 6 338 715 1549 2761 4568 7230 10844 11917 F6400HD 16 16388 8 464 983 2130 3797 6282 9942 14913 16388 F6450HD 18 21705 11 615 1302 2822 5028 8320 13168 19752 21705 F6500HD 20 27908 14 791 1674 3628 6465 10698 16931 25396 27908 F6600HD 24 43116 22 1222 2587 5605 9989 16528 26157 39236 43116 F6750HD 30 73426 37 2081 4405 9545 17011 28146 44545 66818 73426 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 12 F6 Series 2 Way HD Butter y Valve Resilient Seat 304 Stainless Disc Maximum Dimensions Inch
10. 6 7 8 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 114 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Maintenance Instructions Safety Precautions Before removing the valve from the line or loosening any bolts it is important to verify the following conditions 1 Be sure the line is depressurized and drained 2 Be sure of the pipeline media Proper care should be taken for protection against toxic and or flammable fluids 3 Never remove the valve without an Operator Manual or Automatic already attached to the valve shaft 4 Never remove the Operator from the valve while the valve is in the pipeline under pressure 5 Always be sure that the disc is cracked approximately 5 off of the closed position before removing the valve Installation Recommendations Valve Installation Dead End Service 1 Follow previously described pre installation and installation procedures 2 To achieve the full close off pressure of the HD HDU series a flange is required on the open or down stream side of the valve Fig 9 1Fig 9 Installation Consult the Victaulic I 100 field instructional handbook for product installation of the VIC series butterfly valves VIC Series Butter y Valves F6 HD U F7 HD U Series Butter y Valves Valve Installation Dead End Service 1 Follow previously described pre installation and installation procedures 2
11. A B and C do not include ange gaskets 3 required per valve Application Notes 1 Valves are rated at 725 psi differential pressure in the closed position 100 F media temperature 2 Valves are furnished with lugs tapped for use between ANSI Class 250 300 anges conforming to ANSI B16 5 Standards 3 3 way assemblies are furnished assembled with Tee calibrated and tested ready for installation All 3 way assemblies require the customer to specify the 3 way con guration code prior to order entry to guarantee correct place ment of valves and actuator s on the assembly 4 Dimension D allows for actuator s removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data furnished upon request 6 Dual actuated valves have single actuators mounted on each valve shaft 7 Flange gaskets 3 required not provided with valve MUST be used between valve and ANSI ange 8 Flange bolts are not included with the valve These are furnished by others Note For tee con guration please refer to page 5 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 34 200 psi 2 to 12 and 150 psi 14 30 bubble tight shut off Long stem design allows for 2 insulation Valve face to face dimensions comply with API 609 amp MSS SP 67 Completely assembled
12. CARIBBEAN 17 F6 Series 2 Way Victaulic Butter y Valve Maximum Dimensions Inches Valve Size Cv 90 A Max B Max C Max D Max Actuator Close Off PSI F650VIC 2 115 3 21 2 00 8 60 14 00 AF 200 Spring Return F665VIC 2 260 3 77 2 00 8 60 14 50 50 F665VIC 2 260 3 77 8 60 8 60 18 70 2 AF 200 F680VIC 3 440 3 77 8 60 8 60 18 70 50 F665VIC 2 260 3 21 7 00 8 00 14 65 GK 200 Electronic Fail Safe F680VIC 3 440 3 77 7 00 8 00 14 95 50 F6100VIC 4 820 3 77 8 60 8 00 20 25 2 GK 200 F650VIC 2 115 3 21 4 70 8 00 13 20 AM 200 Non Spring Return F665VIC 2 260 3 77 4 70 8 00 13 60 50 F665VIC 2 260 3 77 7 00 8 00 14 00 GM 200 F680VIC 3 440 3 77 7 00 8 00 14 30 50 F6100VIC 4 820 4 63 8 60 8 00 19 60 2 GM 200 F650VIC 2 115 3 21 3 20 2 40 15 70 SY1 200 F665VIC 2 260 3 77 3 20 2 40 16 20 200 F680VIC 3 440 3 77 3 20 2 40 16 40 50 F680VIC 3 440 3 77 4 60 9 20 26 00 SY2 200 F6100VIC 4 820 4 63 4 60 9 20 26 70 200 F6125VIC 5 1200 5 88 4 60 9 20 27 70 SY2 SY3 50 200 F6150VIC 6 1800 5 88 4 60 9 20 28 20 50 200 F6200VIC 8 3400 5 33 7 30 10 90 33 30 SY4 200 F6250VIC 10 5800 6 40 7 30 10 90 35 00 SY4 SY5 50 200 F6300VIC 12 9000 6 50 7
13. CCW CW A B 5 Direction of rotation switch Line Volts 2 to 10 VDC Feedback Signal 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input Org 5 U Output 2 to 10V Pnk 4 Y2 Input 8 3 A B 9 10 11 W558_Butterfly Floating Point 7 Blk 1 Common Red 2 Hot Wht 3 Y1 Input 2 to 10V Org 5 U Output 2 to 10V 4 to 20 mA or 2 to 10 VDC Control Signal Line Volts 24 VAC Transformer 500 1 4 watt 3 5 CCW CW W558_Butterfly VDC 4 20 mA Blk 1 Common Red 2 Hot Wht 3 Y Input Org 5 U Output Line Volts 24 VAC Transformer AC only 8 Position Feedback VDC W558_Butterfly PWM O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 80 GM GR Actuators On Off Floating Point Models GMB24 3 X1 GRB24 3 X1 GRB24 3 5 GRB24 3 7 Technical Data Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 4 0 W holding 2 W Transformer sizing 6 VA class 2 power source Electrical connection 3 ft 18 GA appliance cable 1 2 conduit connector Overload protection electronic throughout 0 to 95 rotation Control signal On Off Floating Point Input impedance 600 Angle of rotation mechanically limited to 95 Direction of rotation reversible wit
14. F F E F E C F ACTUATOR 1 Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control switch and will fail safe position together Building mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 98 O50904 02 12 Subject to change Belimo Aircontrols USA Inc NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for a single proportional SY series 110 VAC actuator Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 99 O50904 02 12 Subject to change Belimo Aircontrols USA Inc K1 A K1 B K2 B K2 A NSV SY 12 G N H A5 A2 A6 M2 M3 AG RD X SA 161 24 BR BK WH RD X OUT IN BK RD BK 1 U5
15. F665HDU 2 196 75 1 81 9 00 9 00 20 00 5 50 4 5 8 11 UNC 50 F680HDU 3 302 116 1 81 9 00 9 00 20 50 6 00 4 5 8 11 UNC 50 F6100HDU 4 600 230 2 05 9 00 9 00 21 00 7 50 8 5 8 11 UNC 2 AF 50 F6125HDU 5 1022 392 2 19 9 00 9 00 22 00 8 50 8 3 4 10 UNC 50 F6100HDU 4 600 230 2 05 8 00 8 00 17 00 7 50 8 5 8 11 UNC GK 50 Electronic Fail Safe F6125HDU 5 1022 392 2 19 8 00 8 00 17 50 8 50 8 3 4 10 UNC 50 F6150HDU 6 1579 605 2 19 8 00 8 00 22 50 9 50 8 3 4 10 UNC 2 GK 50 F650HDU 2 115 44 1 65 7 00 7 00 15 00 4 75 4 5 8 11 UNC AM 50 Non Spring Return F665HDU 2 196 75 1 81 7 00 7 00 15 50 5 50 4 5 8 11 UNC 50 F680HDU 3 302 116 1 81 7 00 7 00 16 00 6 00 4 5 8 11 UNC 50 F6100HDU 4 600 230 2 05 8 00 8 00 17 00 7 50 8 5 8 11 UNC GM 50 F6125HDU 5 1022 392 2 19 8 00 8 00 17 50 8 50 8 3 4 10 UNC 50 F6150HDU 6 1579 605 2 19 8 00 8 00 22 50 9 50 8 3 4 10 UNC 2 GM GK 50 F6150HDU 6 1579 605 2 19 6 00 4 00 18 00 9 50 8 3 4 10 UNC DR DKR 50 F650HDU 2 115 44 1 65 4 25 4 25 15 50 4 75 4 5 8 11 UNC SY1 50 F665HDU 2 196 75 1 76 4 25 4 25 16 00 5 50 4 5 8 11 UNC 50 F680HDU 3 302 116 1 78 4 25 4 25 16 25 6 00 4 5 8 11 UNC 50 F6100HDU 4 600 230 2 05 8 00 13 00 22 00 7 50 8 5
16. F750VIC 2 115 3 20 6 50 13 60 13 60 GM 200 F765VIC 2 260 3 80 7 50 14 10 14 00 50 F765VIC 2 260 3 80 7 50 14 10 14 30 2 GM 200 F780VIC 3 440 3 80 8 00 14 30 19 60 50 F750VIC 2 115 3 20 6 50 15 70 15 70 SY1 200 F765VIC 2 260 3 80 7 50 16 20 16 20 50 F765VIC 2 260 3 80 7 50 25 70 16 40 SY2 200 F780VIC 3 440 3 80 8 00 26 00 26 00 200 F7100VIC 4 820 4 60 9 60 26 70 26 70 200 F7125VIC 5 1200 5 90 11 40 27 70 27 70 SY3 200 F7150VIC 6 1800 5 90 12 40 28 30 28 20 50 F7150VIC 6 1800 5 90 12 40 32 10 33 30 SY4 200 F7200VIC 8 3400 5 30 13 10 33 30 35 00 200 F7250VIC 10 5800 6 40 15 40 35 10 35 10 SY6 50 F7250VIC 10 5800 6 40 15 40 38 70 38 70 SY7 200 F7300VIC 12 9000 6 50 16 50 39 70 39 70 200 SY6 and larger available in 110 220 VAC versions only SY maximum actuator ambient temperature is 150 F Application Notes 1 Valves are rated at 200 psi differential pressure in the closed position 2 2 way assemblies are furnished assembled and tested ready for installation 3 Dimension D allows for actuator removal without the need to remove the valve from the pipe 4 Belimo SY Series actuators are NEMA 4X rated 5 Provide support for the actuator if it is mounted at any angle other than 90 vertical 6 Installer i
17. to OBSERVE POLARITY OF 5 Close to Open to Hot to G 3 1 4 7 4 3 7 6 B A C 5 Open to Close to Hot to G 3 4 3 6 7 3 4 7 B A C C F F E F E C F ACTUATOR 1 NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for multiple on off SY series 24 VAC actuators Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control switch and will fail safe position together Building mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs The 24vac transformer required to run the SYxxx 24 actuator is built in to the NSV cabinet 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 102 O50904 02 12 Subject to change Belimo Aircontrols USA Inc RD 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 U5 C1 C2 Y X SA 161 24 G N H A2 A6 M2 M3 AG BR BK WH RD Analog Signal Input output GND L2 neutral L1 hot RD BK AC DC X NSV SY 12 Mains Powe
18. 100 k for 2 to 10 VDC 0 1 mA 500 for 4 to 20 mA 1000 for oating point and on off control Angle of rotation 90 electronically variable Position indication visual pointer Manual override internal push button UL Type 4 external push buttom UL Type 2 Running time DRX 150 seconds DRCX 35 seconds Humidity 5 to 100 RH UL Type 4 5 to 95 RH non condensation UL Type 2 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 UL Type 2 NEMA 2 IP54 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 DRX24 MFT T DRX24 MFT T N4 DRCX24 MFT T DRCX B 24 MFT T N4 H NEMA 2 NEMA 4 Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC DR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 7 34 186 6 77 172 15 47 393 F07 F6150HDU 6 150 2 19 55 6 7 34 186 6 77 172 16 47 418 F07 Dimensions without Housing A B C D 8 82 224 6 77 172 DRC24A_TP_7LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD
19. 11 22 6 45 5 50 4 5 8 11 UNC 200 21 9 5 F680HD 3 302 116 1 81 4 70 2 10 11 50 6 45 6 00 4 5 8 11 UNC 200 21 9 5 F6100HD 4 600 230 2 06 4 70 2 10 12 17 6 45 7 50 8 5 8 11 UNC GW02 200 27 12 2 F6125HD 5 1022 392 2 19 4 70 2 10 12 72 6 45 8 50 8 3 4 10 UNC 200 32 14 5 F6150HD 6 1579 605 2 19 4 70 2 10 13 19 6 45 9 50 8 3 4 10 UNC 200 37 16 7 F6200HD 8 3136 1202 2 38 8 20 3 10 17 50 9 20 11 75 8 3 4 10 UNC GW03 200 58 26 3 F6250HD 10 5340 2047 2 69 8 20 3 10 18 72 9 20 14 25 12 7 8 9 UNC 200 83 37 6 F6300HD 12 8250 3062 3 06 13 00 3 10 20 55 9 20 17 00 12 7 8 9 UNC GW04 200 130 59 0 F6350HD 14 11917 4568 3 06 13 00 3 10 21 77 9 20 18 75 12 1 8 UNC 150 179 5 81 4 F6400HD 16 16388 6282 4 00 13 00 5 00 25 69 11 40 21 25 16 1 8 UNC GW05 150 270 122 4 F6450HD 18 21705 8320 4 50 13 00 5 00 26 56 11 40 22 75 16 1 1 8 7 UNC GW06 150 314 142 4 F6500HD 20 27908 10698 5 00 15 50 6 80 32 99 11 40 25 00 20 1 1 8 7 UNC GW07 150 477 216 5 F6600HD 24 43116 16528 6 06 16 20 6 80 36 22 12 20 29 50 20 1 1 4 7 UNC GW08 150 725 329 0 F6750HD 30 73426 28146 6 50 17 70 8 10 40 55 13 80 36 00 28 1 1 4 7 UNC GW09 150 1253 568 1 Dimensions Manual Handle D C B H C A Belimovalve_handle_assyModel Dimensi
20. 14 to 30 100 Standard Soft Seat Replacement 1 Place the valve on a bench with the seat retainer facing up Use blocks to elevate the valve above the work surface to provide enough clearance to prevent the disc from being damaged when the valve is opened 2 a Cap Screw Retainer p Remove the cap screws and lift the seat retainer out of the valve b Wedge Ring Retainer g g Unlock the retainer by removing the set screws If dif culty is experienced in removing the retainer open the disc approximately 20 degrees and then tap the retainer with a non metallic hammer Lift the retainer from the body 3 Remove the old seat from the seat retainer and discard 4 Thoroughly clean the seat cavity in the body and the seat retainer prior to installing a new seat O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 41 Maintenance Instructions SHP Series High Performance Butter y Valves Belimo uses a wedge pin method of disc shaft pinning This method permits the replacement of either a disc or a shaft since they are not required to be matched sets 1 Remove any actuator and mounting bracket from top of valve 2 Remove all top and bottom packing and or end seals as required 3 To prepare for removal of existing wedge pins grind away any disc material that has been peened over pin heads 4 a For Through
21. 18 75 20 1 1 8 8 UNC GW20 360 163 3 F6400 300SHP 16 8243 5 25 15 23 4 40 31 90 12 50 21 25 20 1 1 4 8 UNC GW22 435 197 3 F6450 300SHP 18 9712 5 88 16 66 6 50 34 20 17 50 22 75 24 1 1 4 8 UNC GW24 610 276 7 F6500 300SHP 20 10658 6 31 16 66 6 50 37 70 17 50 25 00 24 1 1 4 8 UNC GW26 915 415 0 F6600 300SHP 24 16205 7 19 20 75 7 30 42 80 19 50 29 50 24 1 1 2 8 UNC GW28 1200 544 3 Dimensions Manual Handle Dimension A does not include ange gaskets 2 required per valve Application Notes 1 Valves are rated at 600 psi differential pressure in the closed position 2 Valves are furnished with lugs tapped for use between ANSI Class 250 300 anges conforming to ANSI B16 5 Standards 3 2 way assemblies are furnished assembled and ready for installation 4 Flange gaskets 2 required not provided with valve MUST be used between valve and ANSI ange 5 Flange bolts are not included with the valve These are furnished by others D C B H C A C B E D A B H C Dimensions Gear Wheel SHP series valves have a preferred flow direction PreferredFlowrate Belimo AutoCAD Gear BelimoAutoCAD_Handle F6 Series 2 Way ANSI Class 300 Butter y Valve Reinforced PTFE Seat 316 Stainless Disc with Manual Handle or Gear Wheel Operator O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805
22. 2 F750 300SHP 313 285 89 lbs 94 lbs 2 F765 300SHP 490 285 109 lbs 114 lbs 3 F780 300SHP 705 285 132 lbs 136 lbs 4 F7100 300SHP 1253 150 185 lbs 193 lbs O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 22 ACTUATOR NON SPRING RETURN Size Valve Model Max GPM COP SY2 110 SY3 110 SY4 110 SY5 110 SY7 110 SY8 110 SY9 110 SY10 110 SY11 110 SY 12 110 ANSI 150 2 way 2 F650 150SHP 313 285 39 lbs 2 F665 150SHP 490 285 39 lbs 3 F680 150SHP 705 285 41 lbs 4 F6100 150SHP 1253 285 53 lbs 5 F6125 150SHP 1958 285 58 lbs 6 F6150 150SHP 2820 285 63 lbs 8 F6200 150SHP 5013 150 76 lbs 8 F6200 150SHP 5013 285 100 lbs 10 F6250 150SHP 7834 285 146 lbs 12 F6300 150SHP 11280 150 182 lbs 12 F6300 150SHP 11280 285 182 lbs 14 F6350 150SHP 15354 150 238 lbs 14 F6350 150SHP 15354 285 269 lbs 16 F6400 150SHP 20054 285 336 lbs 18 F6450 150SHP 25381 150 391 lbs 18 F6450 150SHP 25381 285 391 lbs 20 F6500 150SHP 31334 150 500 lbs 20 F6500 150SHP 31334 285 544 lbs 24 F6600 150SHP 45121 150 832 lbs 30 F6750 150SHP 70502 100 1255 lbs 3 way 2 F750 150SHP 313 285 82 lbs 2 F765 150SHP 490 285 93 lbs 3
23. 285 274 lbs 5 F7125 300SHP 1958 600 301 lbs 6 F7150 300SHP 2820 285 366 lbs 6 F7150 300SHP 2820 600 392 lbs 8 F7200 300SHP 5013 400 579 lbs 8 F7200 300SHP 5013 600 579 lbs 8 F7200 300SHP 5013 150 897 lbs 10 F7250 300SHP 7834 285 897 lbs 10 F7250 300SHP 7834 600 931 lbs 10 F7250 300SHP 7834 150 1301 lbs 12 F7300 300SHP 11280 400 1335 lbs 12 F7300 300SHP 11280 600 1335 lbs 12 F7300 300SHP 11280 150 1927 lbs 14 F7350 300SHP 15354 400 1927 lbs 14 F7350 300SHP 15354 600 1975 lbs 14 F7350 300SHP 15354 150 2461 lbs 16 F7400 300SHP 20054 285 2510 lbs 16 F7400 300SHP 20054 400 2510 lbs 16 F7400 300SHP 20054 600 2510 lbs 16 F7400 300SHP 20054 150 3063 lbs 18 F7450 300SHP 25381 285 3111 lbs 18 F7450 300SHP 25381 400 3111 lbs 18 F7450 300SHP 25381 150 4096 lbs 20 F7500 300SHP 31334 285 4096 lbs 24 F7600 300SHP 45121 150 6049 lbs O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 25 Butter y Valve Selection Velocity Chart 150 SHP 300 SHP Series Valves SHP Series Valves are Flow Direction Speci c NON FAIL OPEN OPEN OPEN CLOSED OPEN MASTER COMMON SLAVE M D 11 M D 12 M D 10 M D 13 M D 14
24. 3411 3517 F6300 150SHP 12 4837 73 290 677 1219 1838 2660 3628 4692 4837 F6350 150SHP 14 6857 103 411 960 1728 2606 3771 5143 6651 6857 F6400 150SHP 16 9287 139 557 1300 2340 3529 5108 6965 9008 9287 F6450 150SHP 18 11400 171 684 1596 2873 4332 6270 8550 11058 11400 F6500 150SHP 20 14420 216 865 2019 3634 5480 7931 10815 13987 14420 F6600 150SHP 24 22050 331 1323 3087 5557 8379 12128 16538 21389 22050 F6750 150SHP 30 34388 491 1965 4585 8253 12445 18012 24563 32750 34388 F6 Series 2 Way ANSI Class 150 Butter y Valve Reinforced PTFE Seat 316 Stainless Disc with Manual Handle or Gear Wheel Operator Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 24 Type of end tting for use with ASME class 125 150 ange Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stainless steel RPTFE 17 4 PH stainless PTFE glass backed PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 150 Close off pressure 285 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7
25. 4 100 2 05 52 1 5 81 148 2 64 67 1 13 25 337 F07 F6150HDU 6 150 2 19 55 6 5 81 148 2 64 67 1 14 25 362 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 71 Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered 8 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 9 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 10 For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller Position feedback cannot be used with a Triac sink controller The actuator internal common reference is not compatible 12 IN4004 or IN4007 diode IN4007 supplied Belimo part number 40155 The ZG R01 500 resistor converts the 4 to 20 mA control signal to 2 to 10 VDC up to 2 actuators may be connected in parallel WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components
26. 70 to 220 seconds Angle of rotation adaptation off default Override control min position 0 mid position 50 max position 100 Position indication visual indicator 0 to 95 0 is spring return position Manual override 5 mm hex crank Allen supplied Humidity max 95 RH non condensing Ambient temperature 22 to 122 F 30 to 50 C Storage temperature 40 to 176 F 40 to 80 C Housing NEMA 2 IP54 Enclosure Type 2 Housing material zinc coated metal and plastic casing Noise level 40dB A motor 150 seconds run time dependent 62dB A spring return Agency listings cULus acc to UL60730 1A 2 14 CAN CSA E60730 1 02 CE acc to 2004 108 EC amp 2006 95 EC Quality standard ISO 9001 Servicing maintenance free Weight 4 6 lbs 1 9 kg 4 9 lbs 2 kg with switch Variable when configured with MFT options Rated Impulse Voltage 800V Type of action 1 AA 1 AA B for S version Control Pollution Degree 3 Programmed for 70 sec motor run time At 150 sec motor run time transformer sizing is 8 5 VA and power consumption is 6 W running 3 W holding i AFX24 MFT S X1 Auxiliary switches 2 x SPDT 3A 0 5A 250 VAC UL approved one set at 10 one adjustable 10 to 90 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 63 Wiring Di
27. A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max G Ground 1 Common 3 Open 4 Closed 5 6 7 HTR A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 12 110 220 SY2 12 110 220 Open Close K1 B K1 A Actuator A Actuator B 120 or 230 VAC N L1 H L2 NOTES Caution Power Supply Voltage Isolation relays must be used in parallel connection of multiple actuators using a common control signal input Should be DPDT H L2 cannot be connected to terminal 3 and 4 simultaneously Required Terminal 7 needs to be field wired to enable heater circuit SY1 24 A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication SY1 110 220 A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication SY1 Contact Arrangements G G K1 W549_11 24V AC Transformer Line Voltage G Ground 1 Common 3 Open 4 Closed 5 6 7 HTR A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 5 24 G Ground 1 Common 3 Open 4 Closed 5 6 7 HTR A B C D E F LS3 A C Open Indication
28. CARIBBEAN 61 Typical Specification On Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1 05 diameter The actuators must be designed so that they may be used for either clockwise or counterclockwise fail safe operation Actuators shall be protected from overload at all angles of rotation If required two SPDT auxiliary switch shall be provided having the capability of one being adjustable Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings Actuators shall be cULus approved and have a 5 year warranty and be manufactured under ISO 9001 International Quality Control Standards Actuators shall be as manufactured by Belimo Wiring Diagrams 1 Provide overload protection and disconnect as required 2 CAUTION Equipment Damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 No ground connection is required 4 For end position indication interlock control fan startup etc AFBUP S X1 and AFXUP S X1 incorporates two built in auxiliary switches 2 x SPDT 3A 0 5A 250 VAC UL Approved one switch is xed at 10 one is adjustable 10 to 90 Meets cULus requirements without the need of an electrical ground con nection WARNING Live Electrical Compo
29. CCW CW Slave 24 VAC Transformer Line Volts Control Signal 2 to 10 VDC 3 5 Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U 5 Master_Slave Master Slave O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 84 Models GRCX24 3 T N4 w terminal block GRCB24 3 T N4H w heater Technical Data Control on off oating point Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 8W heater 29W holding 2 5W Transformer sizing 11 VA class 2 power source heater 26 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance 1000 at control input Angle of rotation 90 adjustable with mechanical stop Position indication visual pointer Manual override internal push button UL Type 4 Running time 35 seconds default Humidity 5 to 100 RH UL Type 4 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 GRCX B 24 3 T N
30. Cartridge seat has a much smaller mass of elastomer than traditional boot seat designs limiting seat swell and the accompanying variations in seating torque The five bushing design completely isolates the valve shaft from the body resulting in increased control of the valve disc lower valve seating torque and longer valve life Ductile Iron Full Lug Bodies EPDM liner Stainless Steel Disc Two Models to suit the application HDU Series provides economical HVAC solutions up to 50 psi close off with a 200 psi body rating 2 12 HD Series provides full rated close off to 200 psi 2 12 or 150 psi 14 30 2 way and 3 way applications DUCTILE IRON BODY RPTFE TOP BUSHING EPDM O RING RPTFE BUSHINGS 304SS DISC RPTFE LOWER BUSHING ID TAG ANSI BOLT PATTERN ISO5211 DESIGN 416SS SHAFT PIN Belimo resilient seat HD U Series Butterfly Valves are designed for use in ANSI Class 150 piping systems and are supplied in standard lug style body designs O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 4 Standard Actuation Average Assembly Weights ACTUATOR NON SPRING RETURN SPRING RETURN ELECTRONIC FAIL SAFE Size Valve Max GPM COP AMB X GMB X 2 GMB X AF 2 AF GK 2 GK UNDERCUT MODELS 2 WAY 2
31. Description APC Back UPS 500VA 300W Input 120V Output 120V General Features Addl Surge Protected Outlets Audible Alarms Cord Management Intelligent Battery Management Internet FAX modem DSL protection Overload Indicator Replace Batt Indicator Site wiring fault indicator Software User Replaceable batteries Documentation User Manual Technical Speci cations Input Nominal input 120 V Input frequency 50 60 Hz 5 Hz auto sensing Input Connection Type NEMA 5 15P Cord Length 6 feet Input voltage range for main operations 98 140 V Output Output power capacity 500 VA Output power capacity 300 Watts Nominal output voltage 120 V Waveform type Stepped approximation to a sinewave Output Connections 3 NEMA 5 15R 3 NEMA 5 15R Surge Batteries Typical backup time at half load 11 4 minutes Battery type Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof Typical recharge time 8 hour s Replacement battery cartridge 1 RBC2 Communications amp Management Control panel LED status display with On Line On Battery Replace Battery and Overload indicators Audible alarm Alarm when on battery distinctive low battery alarm overload continuous tone alarm Surge Protection and Filtering Surge energy rating 480 joules Filtering Full time multi pole noise ltering 5 IEEE surge let through zero clamping response time meets UL 1449 Dataline protection RJ 11 Modem F
32. F665 150SHP 2 1 88 9 00 9 00 20 53 5 50 285 F680 150SHP 3 1 92 9 00 9 00 21 03 6 00 285 F6100 150SHP 4 2 13 9 00 9 00 21 53 7 50 150 F650 300SHP 2 1 75 9 00 9 00 20 03 5 00 150 F665 300SHP 2 1 88 9 00 9 00 20 53 5 88 150 F680 300SHP 3 1 92 9 00 9 00 21 03 6 63 150 F6100 300SHP 4 2 13 9 00 9 00 21 53 7 88 150 F6100VIC 4 4 63 8 63 8 63 16 00 200 AM_GM_LineRevised Technical Data Power supply 24VAC 20 50 60Hz Power consumption 12W 3W Transformer sizing 21VA class 2 power source Electrical connection 18 GA plenum rated cable conduit connector protected NEMA 2 IP54 3 ft 1m 10 ft 3m 16 ft 5m Overload protection electronic throughout 0 to 95 rotation Operation range Y on off oating point Input impedance 100k 0 1 mA 500 1500 oating point on off Feedback output U 2 to 10VDC 0 5mA max VDC variable Angle of rotation max 95 adjustable with mechanical stop electronically variable Direction of rotation reversible with switch Fail safe position adjustable with dial or tool 0 to 100 in 10 increments Position indication re ective visual indicator snap on Manual override external push button Running time normal operation fail safe 150 seconds default variable 90 to 150 seconds 35 seconds Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature
33. Field Selectable Fail Direction Readily Available Sealed Lead Acid Battery Packs Provides 500 of Power Requirements for Full Load Cycle Key Lock Hinged Front Steel Controls Enclosure Application Typically applications requiring fail safe operation of actuated devices have had to rely on either the limited power of mechanical spring return actuators or use costly high pressure pneumatic devices to provide fail safe positioning Model NSV series computer grade UPS back up systems designed for use with SY Series electric industrial quarter turn actuators provides the power necessary to drive these actuators to a eld selectable fail safe position The system consists of a painted steel key lock hinged door controls cabinet which houses the logic switching all eld wiring terminal points and a computer grade back up system The back up system is a component level device which utilizes a replaceable spill proof battery pack that can be readily purchased at most of ce supply centers Safety in Numbers The system is designed to provide at a minimum up to 500 of the power required to drive the various actuators through their full 90 degree rotation at full running amperage draws However when the actuators have reached their eld selectable end of travel positions current draw drops to zero and the back up system sits idle until either the time out function integral to the battery is reached or the mains power ret
34. PTFE glass backed PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 150 Close off pressure 285 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 29 Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F750 150SHP 2 102 4 50 6 38 6 38 16 50 4 75 4 5 8 11 UNC GK 150 Electronic Fail Safe F765 150SHP 2 146 5 00 6 88 6 88 17 00 5 50 4 5 8 11 UNC 150 F780 150SHP 3 228 5 50 7 56 7 56 17 50 6 00 4 5 8 11 UNC 150 F750 150SHP 2 102 4 50 6 38 6 38 16 50 4 75 4 5 8 11 UNC 2 GK 285 F765 150SHP 2 146 5 00 6 88 6 88 17 00 5 50 4 5 8 11 UNC 285 F780 150SHP 3 228 5 50 7 56 7 56 17 50 6 00 4 5 8 11 UNC 285 F750 150SHP 2 102 4 50 6 38 6 38 16 50 4 75 4 5 8 11 UNC GM 150 Non Spring Return F765 150SHP 2 146 5 00 6 88 6 88 17 00 5 50 4 5 8 11 UNC 150 F780 150SHP 3 228 5 50 7 56 7 56 17 50 6 00 4 5 8 11 UNC 150 F7100 150SHP 4 451 6 50 8 63 8 63 18 00 7 50 8 5 8 11 UNC 150 F750 150SHP 2 102 4 50 6 38 6 38 16 50 4 75 4 5 8 11 UNC 2 GM 285 F765 150SHP 2
35. Replace Batt Indicator Site wiring fault indicator Software User Replaceable batteries Documentation User Manual Technical Speci cations Input Nominal input 120 V Input frequency 50 60 Hz 5 Hz auto sensing Input Connection Type NEMA 5 15P Cord Length 6 feet Input voltage range for main operations 98 140 V Output Output power capacity 350 VA Output power capacity 210 Watts Nominal output voltage 120 V Waveform type Stepped approximation to a sinewave Output Connections 3 NEMA 5 15R 3 NEMA 5 15R Surge Batteries Typical backup time at half load 11 4 minutes Battery type Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof Typical recharge time 8 hour s Replacement battery cartridge 1 RBC2 Communications amp Management Control panel LED status display with On Line On Battery Replace Battery and Overload indicators Audible alarm Alarm when on battery distinctive low battery alarm overload continuous tone alarm Surge Protection and Filtering Surge energy rating 480 joules Filtering Full time multi pole noise ltering 5 IEEE surge let through zero clamping response time meets UL 1449 Dataline protection RJ 11 Modem Fax DSL protection two wire single line Battery Back Up System For Belimo SY Series Electric Actuators 2 Position or Modulating BACK UPS CS 500VA PART NUMBER BK500 Availability North America Latin America Product Overview
36. Valve Size A B C D Max BHC HD HDU F650HD U 2 1 65 7 00 7 00 15 00 4 75 200 50 F665HD U 2 1 76 7 00 7 00 15 50 5 50 200 50 F680HDU 3 1 78 7 00 7 00 16 00 6 00 50 F650VIC 2 3 21 7 00 7 00 14 50 200 F665VIC 2 3 77 7 00 7 00 14 50 50 D B C A BHC Dimensions with 3 Way Valve Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC HD HDU F750HD 2 4 50 6 15 6 15 15 50 4 75 200 F765HDU 2 5 00 6 76 6 76 16 00 5 50 200 50 F750VIC 2 3 21 6 00 6 00 15 00 50 Single_Butter y 10 0 D A B C O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 77 Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 4 Actuators may also be powered by 24 VDC Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety
37. b Valves 14 and larger g Support the disc on a bench at side down and elevated above the bench top to a height of approximately 4 inches Lower the valve body over the disc seat retainer side facing upward until the bearing bore and disc hole are aligned Install the shaft into the body and disc 13 The shaft keyway when viewed from the top of the valve should be to the right which is also the direction from which the pins are installed 14 Line up the shaft at to permit the insertion of the wedge pins Install the rst wedge pin in the disc hole closest to the top of the valve Finger tight installation is appropriate 15 Move the shaft fully into the valve and against this rst installed pin Insert the second pin Tap both wedge pins in equal amounts until all play between shaft and disc is removed Care should be taken to not over seat the wedge pins If the pin is ush or protruding after tapping in tack weld on the opposite side for security Otherwise peening of the installing side is recommended 16 Install a new end seal if applicable with the end cap as described in Steps 4 through 7 of the End Cap Seal Replacement procedure 17 Install new packing box components as described in Steps 4 through 10 of the Packing Replacement procedure 18 Install new seat as described in the Seat Replacement procedure 19 Cycle the valve several times to ensure the disc is pinned tightly to the shaft and the
38. heater 36 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance 100 k 0 1 mA 500 1500 oating point on off Angle of rotation 90 electronically variable Position indication visual pointer N4 Manual override internal push button UL Type 4 external push buttom UL Type 2 Running time 150 seconds default variable 75 to 290 seconds Fail Safe 35 seconds Humidity 5 to 100 RH UL Type 4 5 to 95 RH non condensation UL Type 2 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 UL Type 2 NEMA 2 IP54 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 Servicing maintenance free DKRX24 MFT T DKRX B 24 MFT T N4 H NEMA 2 NEMA 4 Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC DR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 7 34 186 6 77 172 15 47 393 F07 F6125HD 5 125 2 08 52 8 7 34 186 6 77 172 16 47 418 F07 F6150HDU 6 150 2 19 55 6 7 34 186 6 77 172 16
39. screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance 1000 at control input Angle of rotation 90 Position indication visual pointer Manual override internal push button UL Type 4 external push buttom UL Type 2 Running time 35 seconds default Humidity 5 to 100 RH UL Type 4 5 to 95 RH non condensation UL Type 2 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 UL Type 2 NEMA 2 IP54 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 DRCX24 3 T DRCX B 24 3 T N4 H NEMA 2 NEMA 4 Actuators On Off Floating Point Dimensions with 2 Way Valve D B C A BHC DR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 7 34 186 6 77 172 15 47 393 F07 F6150HDU 6 150 2 19 55 6 7 34 186 6 77 172 16 47 418 F07 Dimensions without Housing A B C D 8 82 224 6 77 172 DRC24A_TP_7LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 6 00 152 3 0
40. 05 9 00 9 00 21 00 7 50 50 F6125HDU 5 2 14 9 00 9 00 22 00 8 50 50 F650 150SHP 2 1 75 9 00 9 00 19 50 4 75 150 F665 150SHP 2 1 88 9 00 9 00 20 00 5 50 150 F680 150SHP 3 1 92 9 00 9 00 20 50 6 00 150 F6100 150SHP 4 2 13 9 00 9 00 21 00 7 50 150 F650 300SHP 2 1 75 9 00 9 00 19 50 5 00 150 F665 300SHP 2 1 88 9 00 9 00 20 00 5 88 150 F680 300SHP 3 1 92 9 00 9 00 20 50 6 63 150 F6100 300SHP 4 2 13 9 00 9 00 21 00 7 88 150 F650VIC 2 3 21 9 00 9 00 18 50 200 F665VIC 2 3 77 9 00 9 00 19 75 50 F665VIC 2 3 77 9 00 9 00 20 50 200 F680VIC 3 3 77 9 00 9 00 20 50 50 AFBUP S X1 AFXUP S X1 AFRBUP S AFRXUP S Actuators On Off Technical Data Power supply 24 240 VAC 20 10 50 60 Hz 24 125 VDC 10 Power consumption running 7 W holding 3 5 W Transformer sizing 7 VA 24 VAC class 2 power source 8 5 VA 120 VAC 18 VA 240 VAC Electrical connection AFBUP AFRBUP 3 ft 18 GA appliance cable 1 2 conduit connector S models Two 3 ft 18 gauge appliance cables with 1 2 conduit connectors AFXUP AFRXUP 3 ft 1m 10 ft 3m or 16 ft 5m 18 GA appliance cable with or without 1 2 conduit connector S models Two 3 ft 1m 10 ft 3m or 16 ft 5m appliance cables with or without 1 2 conduit connectors Overload protection Electro
41. 1 mA 24 VAC max 3A 250 VAC SY2 12 2 SPDT min 1 mA 24 VAC max 5A 250 VAC Ambient temperature 22 F to 150 F 30 C to 65 C Humidity range up to 95 Housing type IP67 NEMA 4X Housing material die cast aluminum alloy Agency listings ISO CE cCSAus Note Leakage current is possible lt 3 5 mA Connect ground before applying voltage Power Supply 120 VAC 50 60Hz single phase Model Torque Speed 60Hz Speed 50Hz Power Consumption Duty Cycle Override Weight On Off Proportional SY1 110 P 35Nm 310 in lbs 12s 13s 0 5A 30 75 8mm Wrench 2 0kg 4 9 lb SY2 120 MFT 90Nm 801 in lbs 15s 17s 1 0A 30 75 Hand Wheel 11kg 24 5 lb SY3 120 MFT 150Nm 1335 in lbs 22s 26s 1 0A 30 75 Hand Wheel 11kg 24 5 lb SY4 120 MFT 400Nm 3560 in lbs 16s 18s 1 3A 30 75 Hand Wheel 22kg 48 5 lb SY5 120 MFT 500Nm 4450 in lbs 22s 25s 1 5A 30 75 Hand Wheel 22kg 48 5 lb SY6 120 MFT 650Nm 5785 in lbs 28s 31s 1 8A 30 75 Hand Wheel 22kg 48 5 lb SY7 120 MFT 1000Nm 8900 in lbs 46s 55s 3 2A 30 75 Hand Wheel 36kg 79 5 lb SY8 120 MFT 1500Nm 13350 in lbs 46s 55s 4 0A 30 75 Hand Wheel 36kg 79 5 lb SY9 120 MFT 2000Nm 17800 in lbs 58s 70s 3 2A 30 50 Hand Wheel 56kg 123 5 lb SY10 120 MFT 2500Nm 22250 in lbs 58s 70s 4 0A 30 50 Hand Wheel 56kg 123 5 lb SY11 120 MFT 3000Nm 26700 in lbs 58s 70s 3 0A 30 50 Han
42. 12 300 F7300VIC F7 Series 3 Way Victaulic Butter y Valve Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed equal percentage Controllable ow range 82 Sizes 2 to 12 Type of end tting grooved ANSI AWWA C606 Valve materials Body Body nish Disc Seat Shaft Bearing ductile iron ASTM A536 grade 65 45 12 black alkyd enamel electroless nickel coated ductile iron EPDM 416 stainless steel berglass with TFE lining Body pressure rating 300 psi Media temperature range 30 F to 250 F 34 C to 120 C Rangeability 100 1 Maximum close off pressure 200 psi Maximum velocity 20 FPS VIC 300 Masterseal as manufactured by Victaulic Company O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 19 Maximum Dimensions Inches Valve Size Cv 90 A Max B Max C Max D Max Actuator Close Off PSI F750VIC 2 115 3 21 2 00 8 60 14 00 AF 50 Spring Return F750VIC 2 115 3 21 2 00 8 60 14 00 2 AF 200 F765VIC 2 260 3 77 8 60 8 60 18 70 50 F750VIC 2 115 3 21 6 50 13 60 15 25 GK 200 Electronic Fail Safe F765VIC 2 260 3 77 7 50 14 10 14 65 50 F780VIC 3 440 3 77 8 00 14 30 20 25 2 GK 50 F750VIC 2 115 3 20 6 50 13 10 13 20 AM 50 Non Spring Return
43. 1335 in lbs 22s 3 0A 30 75 Hand Wheel 11kg 24 5 lb SY4 24 MFT 400Nm 3560 in lbs 16s 6 0A 30 75 Hand Wheel 22kg 48 5 lb SY5 24 MFT 500Nm 4450 in lbs 22s 6 5A 30 75 Hand Wheel 22kg 48 5 lb SY 24V Series Non Spring Return Actuator Technical Data 24 VAC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 44 Application The SY actuators are NEMA 4X rated and designed to meet the needs of HVAC and Commercial applications Offered on Belimo standard and high performance valve series these actuators are available for on off and modulating applications Depending on the application they are available in 24 VAC VDC 120 VAC and 230 VAC Technical Data Electrical connection conduit connector screw terminals Motor protection H Class insulation SY 1 F Class SY 2 12 Gear train high alloy steel gear sets self locking Operating range SY 110 on off floating point SY 120MFT 2 10 VDC 4 20 mA 0 10 VDC Sensitivity SY 120MFT 0 4 mA 200mV Reversal hysteresis SY 120MFT 1 0 mA 500mV Feedback SY 120MFT 2 10 VDC Angle of rotation 90 Direction of rotation reversible Position indication top mounted domed indicator Internal humidity control resistive heating element Auxiliary switches factory set for 5 and 85 change of state SY1 2 SPDT min
44. 150SHP 6 1103 2 29 6 41 3 20 14 50 6 50 9 50 8 3 4 10 UNC 49 22 2 F6200 150SHP 8 2064 2 50 6 41 3 20 15 15 6 50 11 75 8 3 4 10 UNC GW13 58 26 3 F6250 150SHP 10 3517 2 81 6 41 3 20 15 95 6 50 14 25 12 7 8 9 UNC GW15 112 50 8 F6300 150SHP 12 4837 3 23 9 23 4 40 18 05 6 50 17 00 12 7 8 9 UNC GW17 163 73 9 F6350 150SHP 14 6857 3 62 9 23 4 40 21 50 11 38 18 75 12 1 8 UNC GW19 215 97 5 F6400 150SHP 16 9287 4 00 15 23 4 40 30 70 12 50 21 25 16 1 8 UNC GW21 285 129 3 F6450 150SHP 18 11400 4 50 12 23 4 40 29 50 15 00 22 75 16 1 1 8 8 UNC GW23 355 161 0 F6500 150SHP 20 14420 5 00 13 66 6 50 30 70 15 50 25 00 20 1 1 8 8 UNC GW25 500 226 8 F6600 150SHP 24 22050 6 06 16 66 6 90 37 40 17 50 29 50 20 1 1 4 8 UNC GW27 820 371 9 F6750 150SHP 30 34388 6 75 17 75 7 25 40 50 19 50 36 00 28 1 1 4 8 UNC GW29 1350 612 3 C B E D A B H C Dimensions Gear Wheel SHP series valves have a preferred flow direction PreferredFlowrate Dimensions Manual Handle D C B H C A BelimoAutoCAD_Handle Dimension A does not include flange gaskets 2 required per valve Application Notes 1 Valves are rated at 285 psi differential pressure in the closed position 2 Valves are furnished with lugs tapped for use between ANSI Class 125 150 anges conforming to ANSI B16 5 St
45. 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA2 IP54 UL enclosure type 2 Housing material UL94 5VA Agency list cULus acc to UL 60730 1A 2 14 CAN CSA E60730 1 02 CE acc to 2004 108 EEC and 2006 95 EC Noise level lt 45dB A Servicing maintenance free Quality standard ISO 9001 Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GK F765HD 2 5 00 6 70 6 70 16 53 5 50 200 F780HDU 3 5 50 7 20 7 20 16 78 6 00 50 F750 150SHP 2 4 50 6 25 6 25 17 03 4 75 150 F765 150SHP 2 5 00 6 88 6 88 17 53 5 50 150 F780 150SHP 3 5 50 7 42 7 42 18 03 6 00 150 F7100 150SHP 4 6 50 8 63 8 63 18 53 7 50 150 F765VIC 2 3 77 6 88 6 88 15 00 50 F780VIC 3 3 77 7 42 7 42 15 00 200 F7100VIC 4 4 63 8 63 8 63 16 00 50 Dimensions with 3 Way Valve 10 0 D A B C Single_Butter y Models GKRB24 3 X1 GKRB24 3 5 GKB24 3 X1 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 73 GK Actuators On Off Floating Point 1 24 VAC Transformer AC Only Blk 1 Common Red 2 Hot Wht 3 Line Volts 5 GK Y input 1 Pnk 4 W236_13 On Off control xxx xxxx Floating Point control Wiring Diagrams 1
46. 266 17 32 440 F680 150SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F6100 150SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 F650 300SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F665 300SHP 2 5 65 1 88 47 8 3 62 92 10 49 266 17 32 440 F680 300SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F6100 300SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 Dimensions with 3 Way Valve D C B A ZM0824 Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D F750 150SHP 2 50 11 36 288 10 49 266 10 49 266 17 32 440 F765 150SHP 2 5 65 11 43 290 10 49 266 10 49 266 17 32 440 F780 150SHP 3 80 11 47 291 10 49 266 10 49 266 18 07 459 F7100 150SHP 4 100 11 58 294 10 49 266 10 49 266 18 80 478 F750 300SHP 2 50 11 36 288 10 49 266 10 49 266 17 32 440 F765 300SHP 2 5 65 11 43 290 10 49 266 10 49 266 17 32 440 F780 300SHP 3 80 11 47 291 10 49 266 10 49 266 18 07 459 F7100 300SHP 4 100 11 58 294 10 49 266 10 49 266 18 80 478 Note Most F7 versions use dual actuators O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 91 Wiring Diagrams 1 Provide overload protection and disconnect as required 2 CAUTION Equipment Damage
47. 300 Standards Long stem design allows for 2 insulation minimum Valve Face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI 16 5 Flanges Completely assembled and tested ready for installation Tees comply with ASME ANSI 16 5 Class 250 300 Flanges Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN ANSI 150 3 way Spring Non Spring Electronic Fail Safe 100 52 2 F750 300SHP AF Series GM Series SY Series GK Series 143 75 2 F765 300SHP 223 117 3 F780 300SHP 435 228 4 F7100 300SHP 688 361 5 F7125 300SHP 1041 546 6 F7150 300SHP 1911 1001 8 F7200 300SHP 3194 1673 10 F6250 300SHP 4428 2319 12 F7300 300SHP 5702 2986 14 F7350 300SHP 8243 3988 16 F7400 300SHP 9712 5088 18 F7450 300SHP 10658 5775 20 F7500 300SHP 16205 8855 24 F7600 300SHP MOD ON OFF Valve Size Cv 10 20 30 40 50 60
48. 4 x 0 75 mm2 L2 Customer cable Ltot Maximum cable length Cross section L2 T Max cable length Ltot t L1 L2 Example for DC AC DC 0 75 mm2 lt 30 m lt 5 m 1 m L1 4 m L2 1 00 mm2 lt 40 m lt 8 m 1 m L1 7 m L2 1 50 mm2 lt 70 m lt 12 m 1 m L1 11 m L2 2 50 mm2 lt 100 m lt 20 m 1 m L1 19 m L2 L N Y U T 1 3 2 5 A C AC A 24 V AC 230 V L1 A Actuator C Control unit L1 Belimo connecting cable 1 m 4 x 0 75 mm2 m Note Connect via safety isolation transformer Parallel connection of other actuators possible Note performance data for supply DC 0 10 V DC 2 10 V Note When several actuators are connected in parallel the maximum cable length must be divided by the number of actuators Note There are no special restrictions on installation if the supply and data cable are routed separately O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 74 GK Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GK F680HD 3 1 69 9 00 9 00 21 03 6 00 200 F6100HDU 4 1 92 9 00 9 00 21 53 7 50 50 F6125HDU 5 2 08 9 00 9 00 22 53 8 50 50 F6
49. 5 8 11 UNC GM 285 Non Spring Return F665 300SHP 2 143 1 88 9 00 9 00 20 00 5 88 8 3 4 10 UNC 285 F680 300SHP 3 223 1 92 9 00 9 00 20 50 6 63 8 3 4 10 UNC 285 F6100 300SHP 4 435 2 13 9 00 9 00 21 00 7 88 8 3 4 10 UNC 150 F650 300SHP 2 100 1 75 8 00 8 00 22 25 4 75 8 5 8 11 UNC SY2 600 F665 300SHP 2 143 1 88 8 00 8 00 22 75 5 50 8 3 4 10 UNC 600 F680 300SHP 3 223 1 92 8 00 8 00 23 00 6 00 8 3 4 10 UNC 600 F6100 300SHP 4 435 2 13 8 00 8 00 23 75 7 50 8 3 4 10 UNC 600 F6125 300SHP 5 688 2 25 8 00 8 00 24 25 9 25 8 3 4 10 UNC SY2 285 SY3 600 F6150 300SHP 6 1041 2 29 8 00 8 00 24 75 10 63 12 3 4 10 UNC SY2 285 SY3 600 F6200 300SHP 8 1911 2 88 12 00 12 00 32 00 13 00 12 7 8 9 UNC SY3 150 SY4 600 285 F6250 300SHP 10 3194 3 25 12 00 12 00 33 00 15 25 16 1 8 UNC SY5 400 SY7 600 SY4 150 F6300 300SHP 12 4428 3 62 12 00 12 00 35 00 17 75 16 1 1 8 8 UNC SY5 285 SY7 600 SY5 150 F6350 300SHP 14 5702 4 62 14 00 14 00 36 00 20 25 20 1 1 8 8 UNC SY7 400 SY8 600 SY7 150 F6400 300SHP 16 8243 5 25 14 00 14 00 37 50 22 50 20 1 1 4 8 UNC SY8 285 SY9 400 SY10 600 SY7 150 F6450 300SHP 18 9712 5 88 14 00 14 00 42 25 24 75 24 1 1 4
50. 50 16 5 00 16 4 00 16 3 38 14 1 1 8 8 16 2 44 16 2 11 16 6 00 16 5 75 16 4 62 16 4 25 1 1 8 8 4 1 60 4 1 26 4 5 25 4 4 75 4 3 75 4 3 44 16 1 1 4 8 16 2 56 16 2 62 16 6 50 16 6 50 16 4 88 16 4 88 1 1 4 8 4 1 53 4 1 58 4 5 25 4 5 25 4 3 88 4 4 25 18 1 1 4 8 20 2 87 20 2 89 20 7 00 20 7 00 20 5 25 20 5 25 1 1 4 8 4 1 65 4 1 43 4 5 50 4 5 50 4 4 00 4 3 88 20 1 1 4 8 20 3 18 20 3 00 20 7 50 20 7 25 20 5 69 20 5 69 1 1 4 8 4 1 68 4 1 75 4 5 75 4 5 50 4 4 19 4 4 00 24 1 1 2 8 20 3 56 20 3 51 20 8 25 20 8 25 20 6 31 20 6 25 1 1 2 8 4 1 80 4 1 75 4 6 25 4 6 25 4 4 56 4 4 50 Installation Recommendations SHP Series Butter y Valves FLANGE BOLTING RECOMMENDATIONS Flange Detail for ANSI 300 B16 5 Pipe Flanges 300 SHP Series Butter y Valves FLANGES DRILLING BOLTING Nominal Pipe Size A Flange Diameter B Flange Thickness C Diameter of Bolt Circle D Diameter of Bolt Holes Number of Bolts Diameter of Bolts 2 6 50 88 5 00 75 8 5 8 2 1 2 7 50 1 00 5 88 88 8 3 4 3 8 25 1 12 6 63 88 8 3 4 4 10 00 1 25 7 88 88 8 3 4 5 11 00 1 38 9 25 88 8 3 4 6 12 50 1 44 10 63 88 12 3 4 8 15 00 1 62 13 00 1 00 12 7 8 10 17 50 1
51. 7 42 7 42 17 50 6 00 150 285 F750 300SHP 2 5 00 6 75 6 75 15 50 5 00 285 F765 300SHP 2 5 50 7 38 7 38 16 00 5 88 285 F780 300SHP 3 6 00 7 92 7 92 16 25 6 63 285 F7100 300SHP 4 7 00 9 13 9 13 18 00 7 88 150 F750VIC 2 5 00 6 70 6 70 15 50 50 F765VIC 2 5 25 7 25 7 25 15 50 200 F780VIC 3 6 00 7 25 7 25 16 00 50 AM_GM_LineRevised D101 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 83 Wiring Diagrams 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color coded instead Actuators with appliance rated cable use numbers 8 Control signal may be pulsed from either the Hot Source or Common Sink 24 VAC line 10 For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller Meets cULus or UL and CSA requirements without the need of an electrical ground connection 9 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 11 Position feedback cannot be used with a Triac sink controller The actuator internal common reference is not compatible WARNING Live Electrical Components During installation testing servicing and troubleshooting of th
52. 7 50 200 F6100HDU 4 1 92 9 00 9 00 21 00 7 50 50 F6125HDU 5 2 08 9 00 9 00 22 00 8 50 50 F6150HDU 6 2 08 9 00 9 00 22 50 9 50 50 F650 150SHP 2 1 75 9 00 9 00 19 50 4 75 285 F665 150SHP 2 1 88 9 00 9 00 20 00 5 50 285 F680 150SHP 3 1 92 9 00 9 00 20 50 6 00 285 F6100 150SHP 4 2 13 9 00 9 00 21 00 7 50 150 285 F650 300SHP 2 1 75 9 00 9 00 19 50 5 00 285 400 F665 300SHP 2 1 88 9 00 9 00 20 00 5 88 285 400 F680 300SHP 3 1 92 9 00 9 00 20 50 6 63 285 400 F6100 300SHP 4 2 13 9 00 9 00 21 00 7 88 150 285 F665VIC 2 3 77 7 00 7 00 15 50 200 F680VIC 3 3 77 7 00 8 00 15 50 200 F6100VIC 4 4 63 8 00 8 00 16 00 200 Dimensions with 3 Way Valve 10 0 10 0 D A B C Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GM 2 GM F765HD 2 5 00 6 70 6 70 16 00 5 50 200 F780HD 3 5 50 7 20 7 20 16 25 6 00 200 F780HDU 3 5 50 7 20 7 20 16 25 6 00 50 F7100HD 4 6 50 8 45 8 45 17 00 7 50 200 F7100HDU 4 6 50 8 45 8 45 17 00 7 50 50 F7125HDU 5 7 50 9 60 9 60 17 50 8 50 50 F7150HDU 6 8 00 10 08 10 08 18 00 9 50 50 F750 150SHP 2 4 50 6 25 6 25 16 50 4 75 150 285 F765 150SHP 2 5 00 6 88 6 88 17 00 5 50 150 285 F780 150SHP 3 5 50
53. 7 92 7 92 23 00 6 00 8 3 4 10 UNC SY2 400 SY3 600 F7100 300SHP 4 435 7 00 9 13 9 13 23 75 7 50 8 3 4 10 UNC SY2 285 SY3 600 F7125 300SHP 5 688 8 00 10 25 10 25 24 25 8 50 8 3 4 10 UNC SY3 285 SY4 600 F7150 300SHP 6 1041 8 50 10 79 10 79 24 75 9 50 12 3 4 10 UNC SY3 285 SY4 600 F7200 300SHP 8 1911 10 00 12 88 12 88 32 00 11 75 12 7 8 9 UNC SY4 400 SY5 600 SY4 150 F7250 300SHP 10 3194 11 50 14 75 14 75 33 00 14 25 16 1 8 UNC SY5 285 SY7 600 SY5 150 F7300 300SHP 12 4428 13 00 16 62 16 62 35 00 17 00 16 1 1 8 8 UNC SY7 400 SY8 600 SY7 150 F7350 300SHP 14 5200 15 00 19 62 19 62 36 00 18 75 20 1 1 8 8 UNC SY8 400 SY10 600 SY7 150 F7400 300SHP 16 8243 16 50 21 75 21 75 37 50 21 25 20 1 1 4 8 UNC SY9 285 SY10 400 SY12 600 SY8 150 F7450 300SHP 18 9712 18 00 23 88 23 88 42 25 22 75 24 1 1 4 8 UNC SY10 285 SY11 400 F7500 300SHP 20 10568 19 50 25 81 25 81 49 50 25 00 24 1 1 4 8 UNC SY9 150 SY12 285 F7600 300SHP 24 16205 22 5 29 69 29 69 56 25 29 50 24 1 1 2 8 UNC SY12 150 F7 Series 3 Way ANSI Class 300 Butter y Valve Reinforced Te on Seat 316 Stainless Disc 0 S D C A B Dimensions D104 Dimensions
54. 70 80 90 F750 300SHP 2 100 1 40 6 00 13 24 36 52 71 95 100 F765 300SHP 2 143 2 10 8 00 19 34 52 75 102 136 143 F780 300SHP 3 223 3 20 13 30 53 81 117 159 212 223 F7100 300SHP 4 435 6 20 25 58 104 157 228 310 414 435 F7125 300SHP 5 688 10 40 92 165 248 361 491 655 688 F7150 300SHP 6 1041 15 60 139 250 377 546 744 992 1041 F7200 300SHP 8 1911 27 109 255 459 692 1001 1365 1820 1911 F7250 300SHP 10 3194 46 183 426 767 1156 1673 2282 3042 3194 F7300 300SHP 12 4428 63 253 590 1063 1602 2319 3163 4217 4428 F7350 300SHP 14 5702 81 326 760 1368 2063 2986 4072 5430 5702 F7400 300SHP 16 8243 109 435 1015 1827 2755 3988 5438 7850 8243 F7450 300SHP 18 9712 139 555 1295 2331 3515 5088 6938 9250 9712 F7500 300SHP 20 10658 158 630 1470 2646 3990 5775 7875 10150 10658 F7600 300SHP 24 16205 242 966 2254 4057 6118 8855 12075 16100 16205 F7 Series 3 Way ANSI Class 300 Butter y Valve Reinforced Te on Seat 316 Stainless Disc Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 24 Type of end tting ANSI 300 anges Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stain
55. 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 40 Maintenance Instructions SHP Series High Performance Butter y Valves Safety Precautions Before removing the valve from the line or loosening any bolts it is important to verify the following conditions 1 Be sure the line is depressurized and drained 2 Be sure of the pipeline media Proper care should be taken for protection against toxic and or ammable uids 3 Never install the valve without an Operator Manual or Automatic already attached to the valve shaft 4 Never remove the Operator from the valve while the valve is in the pipeline under pressure Belimo s valve design may allow line pressure to open the valve if the handle actuator is not in place while the valve is under pressure 5 Always be sure that the disc is in the full closed position before removing or installing the valve 6 Take care in handling the valve Personal injury or property damage may result if the valve is damaged or mishandled during maintenance operations General Maintenance Normal maintenance for a Belimo SHP valve is limited to adjustment of the shaft packing by tightening down evenly on the gland ange using the gland ange studs and nuts Overtightening of the gland should be avoided since this will shorten the life of the packing During commissioning it is common for dirt and foreign objects to be left in the pipeline during construction This debris can damage
56. 88 150 285 F665VIC 2 3 77 7 00 7 00 15 50 200 F680VIC 3 3 77 7 00 8 00 15 50 200 F6100VIC 4 4 63 8 00 8 00 16 00 200 AM_GM_LineRevised O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 81 Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury GM GR Actuators On Off Floating Point 2 3 5 24 VAC Transformer a open a closed Blk 1 Common Red 2 Wht 3 a Line Volts The indication of direction is valid for switch position 1 GMB24 3 X1 1 0 W559
57. 99 102 F765 150SHP 2 146 2 20 8 80 20 37 55 80 110 142 146 F780 150SHP 3 228 3 40 14 32 57 87 125 171 221 228 F7100 150SHP 4 451 6 80 27 63 114 171 248 338 437 451 F7125 150SHP 5 714 11 43 100 180 271 393 536 693 714 F7150 150SHP 6 1103 17 66 154 278 419 607 827 1070 1103 F7200 150SHP 8 2064 31 124 289 520 784 1135 1548 2002 2064 F7250 150SHP 10 3517 53 211 492 886 1336 1934 2638 3411 3517 F7300 150SHP 12 4837 73 290 677 1219 1838 2660 3628 4692 4837 F7350 150SHP 14 6857 103 411 960 1728 2606 3771 5143 6651 6857 F7400 150SHP 16 9287 139 557 1300 2340 3529 5108 6965 9008 9287 F7450 150SHP 18 11400 171 684 1596 2873 4332 6270 8550 11058 11400 F7500 150SHP 20 14420 216 865 2019 3634 5480 7931 10815 13987 14420 F7600 150SHP 24 22050 331 1323 3087 5557 8379 12128 16538 21389 22050 F7 Series 3 Way ANSI Class 150 Butter y Valve Reinforced Te on Seat 316 Stainless Disc Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 24 Type of end tting for use with ASME class 125 150 anges Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stainless steel RPTFE 17 4 PH stainless
58. FROM TERMINAL 3 AND A CONNECT TO TERMINAL A6 ON THE NSV A5 NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for multiple proportional SY series 24 VAC actuators Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control signal and will fail safe position together Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuators as shown Observe wire size rules for longer wire runs The 24vac transformer required to run the SYxxx 24 actuator is built in to the NSV cabinet K1 and K2 must be supplied 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 104 O50904 02 12 Subject to change Belimo Aircontrols USA Inc AUTOMATION SYSTEM OR SWITCH NSV SY 25 NSV SY 23 NSV SY 21 FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G L2 CLOSE OPEN A8 L1 220VAC M3 M2 SY 1 12 220 D 5A 250VAC MAX ACTUATOR 1 AUX SW TERMINALS Opened to Closed to 5 Close to Open to Hot to G 3 1 4 7 4 3 7 6 B A C C F F E NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for a single on off SY series
59. GMX24 MFT X1 GRX24 MFT X1 GRB24 MFT 5 GRX24 MFT 7 Technical Data Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 4 5 W holding 2 W Transformer sizing 7 VA class 2 power source Electrical connection 3 ft 18 GA appliance cable 1 2 conduit connector Overload protection electronic throughout 0 to 95 rotation Control signal 2 to 10 VDC 4 to 20 mA with 500 1 4 W resistor ZG R01 Input impedance 100 k for 2 to 10 VDC 0 1 mA 500 for 4 to 20 mA 750 for PWM 1500 for on off and oating point Angle of rotation mechanically limited to 95 Direction of rotation reversible with switch A B Position indication 0 to 1 and reversible indicator Running time 150 seconds Humidity 5 to 95 RH non condensing Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA 2 IP54 Housing material UL94 5VA ammability rating Agency listings cULus according to UL60730 1A 2 14 CAN CSA E60730 1 CSA C22 2 No 24 93 CE according to 89 336 EEC Noise level max 45 dB A Servicing maintenance free Quality standard ISO 9001 GM GR Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GM 2 GM F680HD 3 1 69 9 00 9 00 20 50 6 00 200 F6100HD 4 1 92 9 00 9 00 21 00
60. Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury DRX24 MFT T DRX24 MFT T N4 DRCX24 MFT T DRCX B 24 MFT T N4 H NEMA 2 NEMA 4 Actuators Multi Function Technology WARNING Mechanical Precautions The mechanical end stops cannot be moved or repositioned Doing so will adversely effect the operation of the valve The directional switch cannot be moved Maintain Factory Settings W538 On Off Control CCW CW Line Volts 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input 5 U Output 2 to 10V A B 2 9 8 10 12 Feedback Signal 2 to 10 VDC 5 Floating Point AC Only W538 VDC 4 20 mA MFT O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 72 GK Actuators On Off Floating Point Dimensions with 2 Way Valve D B C A BHC Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GK F680HD 3 1 78 7 00 7 00 16 53 6 00 200 F6100HDU 4 2 05 8 00 8 00 17 53 7 50 50 F6125HDU 5 2 14 8 00 8 00 18 03 8 50 50 F650 150SHP 2 1 75 9 00 9 00 20 03 4 75 285
61. Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 79 Wiring Diagrams 3 Actuators may also be powered by 24 VDC 4 Position feedback cannot be used with Triac sink controller The actuator internal common reference is not compatible 6 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 8 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 9 For triac sink the common connection from the actuator must be connected to the hot connection The ZG R01 500 resistor converts the 4 to 20 mA control signal to 2 to 10 VDC up to 2 actuators may be connected in parallel WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury AM AR Series Actuators Multi Function Technology Blk 1 Common Red 2 Hot Wht 3 Y Input Org 5 U Output Line Volts 24 VAC DC Transformer a Position Feedback VDC 3 W558_Butterfly Two Position CCW CW A B 5
62. LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 5 24 K1 Open Close K1 B K1 A Actuator A Actuator B G G Wiring for Control Valves On Off 24V 110 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 56 SY Actuator Wiring Diagram SY1 24P Multiple Wiring Observe class 1 and class 2 wiring restrictions Transformer sizing SY actuator draw X 1 25 safety margin Ex SY2 24 requires 3 0A x 1 25 3 75A 3 75A X 24 VAC 90VA Transformer Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment Equipment damage Power consumption and input impedance must be observed Isolation relays are required in parallel applications The reason parallel applications need isolation relays is that the motor uses two sets of windings one for each direction When one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first It s called back EMF This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow it has no magnetic effect on the motor On parallel applications without isolation this EMF voltage energizes the winding it is connected to on the other actuators i
63. MACHINE BOLTS LUG BODY STUDS and NUTS Bolting and torque recommendations are made without warranty and apply only to steel weld neck or slip on flanges The use of lock washers and or lubrication with the bolting will affect stated torque values Length of machine bolts based on 1 Gasket thickness of 0 06 inches 2 Minimum flange thickness of weld neck flanges per ANSI B16 5 and B16 47 Series A Variation to specified bolting length may result in improper installation FLANGE BOLTING RECOMMENDATIONS Flange Detail for ANSI 150 B16 5 Pipe Flanges 150 SHP Series Butterfly Valves FLANGES DRILLING BOLTING Nominal Pipe Size A Flange Diameter B Flange Thickness C Diameter of Bolt Circle D Diameter of Bolt Holes Number of Bolts Diameter of Bolts 2 6 3 4 4 3 4 3 4 4 5 8 2 1 2 7 7 8 5 1 2 3 4 4 5 8 3 7 1 2 15 16 6 3 4 4 5 8 4 9 15 16 7 1 2 3 4 8 5 8 5 10 15 16 8 1 2 7 8 8 3 4 6 11 1 9 1 2 7 8 8 3 4 8 13 1 2 1 1 8 11 3 4 7 8 8 3 4 10 16 1 3 16 14 1 4 1 12 7 8 12 19 1 1 4 17 1 12 7 8 14 21 1 3 8 18 3 4 1 1 8 12 1 16 23 1 2 1 7 16 21 1 4 1 1 8 16 1 18 25 1 5 8 22 3 4 1 1 4 16 1 1 8 20 27 1 2 1 11 16 25
64. MAXIMUM FLOW OF VALVE OPENING BF2WUDIM O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 9 F7 Series 3 Way HDU Butter y Valve Resilient Seat 304 Stainless Disc Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed linear Controllable ow range 82 Sizes 2 to 12 Type of end tting for use with ANSI 125 150 anges Materials Body Body nish Disc Seat Shaft O ring Bushings ductile iron ASTM A536 epoxy powder nish 304 stainless steel EPDM standard 416 stainless steel EPDM RPTFE Media temperature range 22 F to 250 F 30 C to 120 C Body pressure rating ASME ANSI Class 125 Close off pressure 50 psi Rangeability 10 1 for 30 to 70 range Maximum velocity 12 FPS Leakage bubble tight 50 psi bubble tight shut off Long stem design allows for 2 insulation Valve face to face dimensions comply with API 609 amp MSS SP 67 Completely assembled and tested ready for installation Tees comply with ASME ANSI B16 1 Class 125 anges Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process co
65. Provide overload protection and disconnect as required 3 Actuators may also be powered by 24 VDC 4 Position feedback cannot be used with Triac sink controller The actuator internal common reference is not compatible 5 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 8 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 9 For triac sink the common connection from the actuator must be connected to the hot connection of the controller Meets UL requirements without the need of an electrical ground connection WARNING Live Electrical Components G During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury NOTE Wiring diagrams shown are for single actuator mounted solutions Electrical Installation Wiring diagram Y U 1 3 2 5 T Cable colors 1 black 2 red 3 white 5 orange Cable lengths Y U 1 3 2 5 T A C L1 L2 Ltot A Actuator C Control unit L1 Belimo connecting cable 1 m
66. RH UL Type 4 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 GMCX B 24 3 T X1 N4 H NEMA 4 Actuators On Off Floating Point Dimensions with 2 Way Valve D B C A ZM0825 Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D F650 150SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F665 150SHP 2 5 65 1 88 47 8 3 62 92 10 49 266 17 32 440 F680 150SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F6100 150SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 F650 300SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F665 300SHP 2 5 65 1 88 47 8 3 62 92 10 49 266 17 32 440 F680 300SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F6100 300SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 Dimensions with 3 Way Valve D C B A ZM0824 Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D F750 150SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F765 150SHP 2 5 65 1 88 47 8 3 62 92 10 49 266 17 32 440 F780 15
67. Size Type Manual Operators Cv 90 Cv 60 IN DN mm ANSI 300 2 way 100 52 2 50 F650 300SHP Handle Gear Wheel OP 143 75 2 65 F665 300SHP 223 117 3 80 F680 300SHP 435 228 4 100 F6100 300SHP 688 361 5 125 F6125 300SHP 1041 546 6 150 F6150 300SHP 1911 1001 8 200 F6200 300SHP 3194 1673 10 250 F6250 300SHP 4428 2319 12 300 F6300 300SHP 5702 2986 14 350 F6350 300SHP 8243 3988 16 400 F6400 300SHP 9712 5088 18 450 F6450 300SHP 10658 5775 20 500 F6500 300SHP 16205 8855 24 600 F6600 300SHP Valve Size Cv 10 20 30 40 50 60 70 80 90 F650 300SHP 2 100 1 4 6 13 24 36 52 71 95 100 F665 300SHP 2 143 2 1 8 19 34 52 75 102 136 143 F680 300SHP 3 223 3 2 13 30 53 81 117 159 212 223 F6100 300SHP 4 435 6 2 25 58 104 157 228 310 414 435 F6125 300SHP 5 688 10 40 92 165 248 361 491 655 688 F6150 300SHP 6 1041 15 60 139 250 377 546 744 992 1041 F6200 300SHP 8 1911 27 109 255 459 692 1001 1365 1820 1911 F6250 300SHP 10 3194 46 183 426 767 1156 1673 2282 3042 3194 F6300 300SHP 12 4428 63 253 590 1063 1602 2319 3163 4217 4428 F6350 300SHP 14 5702 81 326 760 1368 2063 2986 4072 5430 5702 F6400 300SHP 16 8243 109 435 1015 1827 2755 3
68. also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification INSTALLATION NOTES NOTES SY1 5 24 Each actuator should be powered by a single isolated control transformer using a common control signal input 24V AC DC Transformer Line Volts Open Close G Ground 1 Common 3 Open 4 Closed 5 6 7 G Ground 1 Common 3 Open 4 Closed 5 6 7 HTR A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 5 24 120V or 230V AC DC G Open Close G N L1 H L2 HTR A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 12 120V or 230V NOTES SY1 12 120V or 230V Caution Power Supply Voltage using a common control signal input SY1 24 A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication SY1 110 220 A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication SY1 Contact Arrangements 33 33 W546_12 Wiring for Control Valves On Off 24V 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 86
69. button Running time normal operation fail safe 95 seconds default variable 90 to 150 seconds 35 seconds Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA2 IP54 UL enclosure type 2 Housing material UL94 5VA Agency list cULus acc to UL 60730 1A 2 14 CAN CSA E60730 1 02 CE acc to 2004 108 EEC and 2006 95 EC Noise level lt 45dB A Servicing maintenance free Quality standard ISO 9001 Note GKR Actuators are on 2 way valves GKX Actuators are on 3 way valves Dimensions with 3 Way Valve Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GK 2 GK F780HDU 3 5 50 7 20 7 20 16 78 6 00 200 F7100HDU 4 6 50 8 55 8 55 17 00 7 50 50 F7125HDU 5 7 50 9 64 9 64 17 50 8 50 50 F7150HDU 6 8 00 10 19 10 19 22 50 9 50 50 F750 150SHP 2 4 50 6 25 6 25 17 03 4 75 150 F765 150SHP 2 5 00 6 88 6 88 17 53 5 50 150 F780 150SHP 3 5 50 7 42 7 42 18 03 6 00 150 F765VIC 2 3 77 6 88 6 88 15 00 50 F780VIC 3 3 77 7 42 7 42 15 00 200 F7100VIC 4 4 63 8 63 8 63 16 00 50 Single_Butter y 10 0 D A B C Models GKRX24 MFT X1 GKX24 MFT X1 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 708
70. cable Ltot Maximum cable length Cross section L2 T Max cable length Ltot t L1 L2 Example for DC AC DC 0 75 mm2 lt 30 m lt 5 m 1 m L1 4 m L2 1 00 mm2 lt 40 m lt 8 m 1 m L1 7 m L2 1 50 mm2 lt 70 m lt 12 m 1 m L1 11 m L2 2 50 mm2 lt 100 m lt 20 m 1 m L1 19 m L2 L N Y U T 1 3 2 5 A C AC A 24 V ACC 230 V L1 A Actuator C Control unit L1 Belimo connecting cable 1 m 4 x 0 75 mm2 m Note Connect via safety isolation transformer Parallel connection of other actuators possible Note performance data for supply DC 0 10 V DC 2 10 V Note When several actuators are connected in parallel the maximum cable length must be divided by the number of actuators Note There are no special restrictions on installation if the supply and data cable are routed separately 3 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 66 Models DKRX24 MFT T w terminal block DKRX24 MFT T N4 w terminal block DKRB24 MFT T N4H w heater Technical Data Control 2 to 10 VDC 4 to 20 mA default variable VDC oating point on off Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 12 W heater 33W holding 3 W Transformer sizing 21 VA class 2 power source
71. calibrated and should not be moved 3 Motor CAMS have been factory calibrated and should not be moved Dip Switch Settings Sensitivity switch s e s tting is position 3 for factory default To T widen dead band select a higher number up to 9 WARNING On modulating actuators DO NOT master r slave using optional potentiometer INSTALLATION NOTES CAUTION LED Close LED Open N Power Supply 3 Power Supply 4 Control Signal 5 Control Signal 6 Feedback 11 Feedback 12 VR1 VR2 Sensitivity O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 51 LS2 Clockwise Decrease Closed Angle CLOSE Counter clockwise Increase Closed Angle LS1 Clockwise Increase Opening Angle OPEN Counter clockwise Decrease Opening Angle LS4 Auxiliary Switch for Closed Indication LS3 Auxiliary Switch for Opened Indication F E D C B A 0 5 85 90 LS3 A B A C 0 5 85 90 LS4 D F D E Switches at left are shown with actuator fully open LS3 LS4 LS1 LS2 LS3 LS4 Factory pre set see chart below Field adjustable if required LS4 Auxiliary Switch for Closed Indication LS3 Auxiliary Switch for Opened Indication Factory pre set see chart below Field adjustable if required Factory pre set and calibrated Do not a
72. disc or seat faces Note Actuator must be mounted at or above pipe center line for all actuator types Fig 6 1 For Lug style valves a Place the valve between the anges b Install all bolts between the valve and the mating anges Hand tighten bolts as necessary Fig 7 2 Before completing the tightening of any bolts the valve should be centered between the anges and then carefully opened and closed to insure free unobstructed disc movement 3 Using the sequence Fig 8 tighten the ange bolts evenly to assure uniform compression In assembling ange joints the resilient seating surface shall be uniformly compressed Fig 5 4 If an actuator is to be operated electricity should be connected to the unit in accordance with the local electrical codes 5 Cycle the valve to the fully open position then back to the fully closed position checking the actuator travel stop settings for proper disc alignment The valve should be operated to assure that no binding is taking place If no power is available use the manual handwheel 6 The valve is now ready for operation 1Fig 7 Installation Recommendations F6 HD U F7 HD U Series Butter y Valves Fig 5 gt 0 0 0 gt 0 Fig 6 90 90 1Fig 8 3 1 2 4 1 4 3 2 5 6 7 8 9 10 11 12 13 14 15 16 1 4 3 2 5 6 7 8 9 10 11 12 1 4 3 2 5
73. harsh environmental conditions 4 Store the valve with the disc in the closed position to protect the sealing edge and the seat 5 Keep the valve in a clean location away from dirt debris and corrosive materials 6 Keep the valve in a dry area with the flange protectors attached 7 Keep the valve in a cool location if possible out of direct sunlight 8 If not in use exercise the butterfly valve full open and close at least once a month Installation Recommendations SHP Series Butter y Valves 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 116 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Butter y Sizing and Selection CONSULT CHART ON PAGE 21 Flow in Standard Weight Pipe Fluid Velocity in GPM For SHP Series Butterfly Valves the 32 ft second column is applied For example Application requires a 2 way 600 GPM Butterfly valve a valve of 3 minimum would be selected The 3 valve at 32 ft second would be able to withstand a capacity of 705 GPM without damage to the seat Notes 1 Most Butterflies are line size and piping geometry is not considered If valve size must be reduced a recommendation is to select a valve only one size less than the pipe Do not exceed velocity limit 2 For a modulating Butterfly valve the Cv rating is determined at 60 open For a 2 position Butterfly valve the Cv is determined at 90 open Consult Be
74. insulation Valve face to face dimensions comply with API 609 amp MSS SP 67 Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Designed for use in Victaulic piping systems when mated to Victaulic 41 series ange nipples Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F6 HD Butter y Valves Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN DN mm 2 way Spring Non Spring Electronic Fail Safe 115 44 2 50 F650HD AF Series AM SY Series 196 75 2 65 F665HD 302 116 3 80 F680HD GM GK 600 230 4 100 F6100HD DR DKR 1022 392 5 125 F6125HD 1579 605 6 150 F6150HD 3136 1202 8 200 F6200HD 5340 2047 10 250 F6250HD 8250 3062 12 300 F6300HD 11917 4568 14 350 F6350HD 16388 6282 16 400 F6400HD 21705 8320 18 450 F6450HD 27908 10698 20
75. precautions when exposed to live electrical components could result in death or serious injury AM AR Series Actuators On Off Floating Point j y 2 3 5 24 VAC Transformer a open a closed Blk 1 Common Red 2 Wht 3 a Line Volts The indication of direction is valid for switch position 1 AMB24 3 X1 1 0 W557_10 On Off control 24 VAC Transformer Blk 1 Common Red 2 Wht 3 Line Volts The indication of direction is valid for switch position 1 2 3 5 AMB24 3 X1 1 0 W557_10 Floating Point or On Off control O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 78 Models AMX24 MFT X1 ARX24 MFT X1 ARB24 MFT 5 Technical Data Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 4 W holding 1 25 W Transformer sizing 6 VA class 2 power source Electrical connection 3 ft 1m 10 ft 3m 16 ft 5m 18 GA plenum rated cable conduit connector Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC 4 to 20 mA default variable VDC PWM oating point on off Input impedance 100k 0 1 mA 500 1500 PWM oating point on off Feedback output U 2 to 10 VDC 0 5 mA max VDC variable Angle of rotation 95 electronically variable Direction of rotation reversible w
76. requirements of ANSI B16 21 1978 Thick elastomeric gaskets are not recommended Metallic wound Flexitallic gaskets may also be used Pipe Schedule Compatibility The SHP valve is designed to allow the disc edge to rotate into the open position without interference with the pipeline I D in the following pipe schedules SIZE ANSI 150 ANSI 300 2 12 SCH 80 SCH 80 14 24 SCH 40 SCH 80 30 SCH 30 SCH 80 36 42 STD WT 48 XS Product Identification 1 Every SHP valve has a metal identification tag attached to the valve body Information includes the Figure Number the Size and Pressure Class the Materials of Construction and the Operating Pressures and Temperatures 2 Every SHP valve is hydrostatically tested before it is shipped The metal tag also includes a Serial Number this number unique for each valve is recorded by the Belimo Quality Control Department along with the test results and material certification data for individual traceability and verification of every valve produced SHP series valves have a preferred flow direction PreferredFlowrate UNPACKING AND STORAGE INSTRUCTIONS 1 Check the packing list against the valve received to verify that the quantities sizes and materials are correct 2 Check to make sure that the valve and operator were not damaged during shipment 3 If the valve is to be stored before being installed it should be protected from
77. the flange faces are clean and free of rust scale and debris to prevent damage to the flange gasket Follow the recommended flange bolting sequence found in the Installation Recommendations section of this guide Installation using Welded Flanges Mount flanges on both sides of valve body and install bolts to properly align valve body and both flanges Make sure the valve I D and flange internal diameters are in alignment Take valve body flange pair assembly and align with piping ends TACK weld the flanges to the piping in several places Do NOT seam weld at this time Remove the lug bolts and carefully remove the valve body from the flanges Seam weld the entire flange piping connection for both flanges Let the piping components cool completely before re inserting the valve body WARNING Seam welding with the valve body installed between the flanges can damage the valve seats due to heat migration through the flange to the valve body SHP Series Butter y Valves 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 117 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Pre Installation Procedure 1 Remove the protective face covers from the valve 2 Inspect the valve to be certain the waterway is free from dirt and foreign matter Be certain the adjoining pipeline is free from any foreign material such as rus
78. upon request 6 Dual actuated valves have actuators mounted on a common valve shaft 7 Belimo SY Series actuators are NEMA 4X rated D A B C Dimensions BF2WUDIM Flow Pattern 0 10 20 10 30 50 40 60 80 70 90 20 30 40 60 50 70 80 100 90 100 OF MAXIMUM FLOW OF VALVE OPENING O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 13 F7 Series 3 Way HD Butter y Valve Resilient Seat 304 Stainless Disc Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed linear Controllable ow range 82 Sizes 2 to 24 Type of end tting for use with ANSI 125 150 anges Materials Body Body nish Disc Seat Shaft O ring Bushings ductile iron ASTM A536 epoxy powder coated 304 stainless steel EPDM standard 416 stainless steel EPDM RPTFE Media temperature range 22 F to 250 F 30 C to 120 C Body pressure rating ASME ANSI Class 125 150 Close off pressure 200 psi 2 12 150 psi 14 24 Rangeability 10 1 for 30 to 70 range Maximum Velocity 12 FPS 200 psi 2 to 12 and 150 psi 14 30 bubble tight shut off Long stem design allows for 2 insulation Valve face to face dimensions comply with API 609 amp MSS SP 67 Completely assembled and tested ready for inst
79. with ANSI Class 125 150 anges Materials Body Body nish Disc Seat Shaft O ring Bushings ductile iron ASTM A536 epoxy powder coated 304 stainless steel EPDM 416 stainless steel EPDM RPTFE Media temperature range 22 F to 250 F 30 C to 120 C Body pressure rating ASME ANSI Class 125 Close off pressure 50 psi Rangeability 10 1 for 30 to 70 range Maximum velocity 12 FPS Leakage bubble tight 50 psi bubble tight shut off Long stem design allows for 2 insulation Valve face to face dimensions comply with API 609 amp MSS SP 67 Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Designed for use in Victaulic piping systems when mated to Victaulic 41 series ange nipples Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F6 HDU Butter y Valves Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN DN mm 2
80. 0 54 60 1 3 4 1800 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 111 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 1Fig 2 0 gt 0 1Fig 3a 1 2 1Fig 3b 1Fig 4 Installation Recommendations F6 HD U F7 HD U Series Butter y Valves HD U Series Butter y Valves 1Fig 1 15 20 Fig 1a 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 112 O50904 02 12 Subject to change Belimo Aircontrols USA Inc FLANGE BOLTING RECOMMENDATIONS Lug Valves 2 30 ANSI 125 150 Bolt Pattern Valve Size Thread Size Number Required Bolt Length Semi Lug Butter y inches 2 5 8 11 4 1 25 2 1 2 5 8 11 4 1 50 3 5 8 11 4 1 50 4 5 8 11 8 1 75 5 3 4 10 8 1 75 6 3 4 10 8 2 00 8 3 4 10 8 2 25 10 7 8 9 12 2 25 12 7 8 9 12 2 50 14 1 8 12 2 75 16 1 8 16 2 75 18 1 1 8 7 16 3 50 20 1 1 8 7 20 4 25 24 1 1 4 7 20 4 75 30 1 1 4 7 24 4 50 PRE INSTALLATION PROCEDURE 1 Remove any protective ange covers from the valve 2 Inspect the valve to be certain the waterway is free from dirt and foreign matter Be certain the adjoining pipeline is free from any foreign material such as rust and pipe scale or welding slag that could damage the seat and disc sealing surfaces 3 Any actuator sh
81. 0 SY10 285 F6600 150SHP 24 22050 6 06 14 00 14 00 56 25 29 50 20 1 1 4 8 UNC SY10 150 F6750 150SHP 30 34388 6 75 14 00 14 00 66 58 36 00 28 1 1 4 8 UNC SY12 125 F6 Series 2 Way ANSI Class 150 Butter y Valve Reinforced Te on Seat 316 Stainless Disc Dimension A does not include flange gaskets 2 required per valve Application Notes 1 Valves are rated at 285 psi differential pressure in the closed position 100 F media temperature 2 Valves are furnished with lugs tapped for use between ANSI Class 125 150 anges conforming to ANSI B16 5 Standards 3 2 way assemblies are furnished assembled calibrated and tested ready for installation 4 Dimension D allows for actuator s removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data furnished upon request 6 Flange gaskets 2 required not provided with valve MUST be used between valve and ANSI ange 7 Flange bolts are not included with the valve These are furnished by others Dimensions D B C A BHC D102 SHP series valves have a preferred flow direction PreferredFlowrate O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 28 Bubble tight shut off to ANSI Class 150 Standards Long stem design allows for 2 insulation m
82. 0 13 24 36 52 71 95 100 F665 300SHP 2 143 2 10 8 00 19 34 52 75 102 136 143 F680 300SHP 3 223 3 20 13 30 53 81 117 159 212 223 F6100 300SHP 4 435 6 20 25 58 104 157 228 310 414 435 F6125 300SHP 5 688 10 40 92 165 248 361 491 655 688 F6150 300SHP 6 1041 15 60 139 250 377 546 744 992 1041 F6200 300SHP 8 1911 27 109 255 459 692 1001 1365 1820 1911 F6250 300SHP 10 3194 46 183 426 767 1156 1673 2282 3042 3194 F6300 300SHP 12 4428 63 253 590 1063 1602 2319 3163 4217 4428 F6350 300SHP 14 5702 81 326 760 1368 2063 2986 4072 5430 5702 F6400 300SHP 16 8243 109 435 1015 1827 2755 3988 5438 7850 8243 F6450 300SHP 18 9712 139 555 1295 2331 3515 5088 6938 9250 9712 F6500 300SHP 20 10658 158 630 1470 2646 3990 5775 7875 10150 10658 F6600 300SHP 24 16205 242 966 2254 4057 6118 8855 12075 16100 16205 F6 Series 2 Way ANSI Class 300 Butter y Valve Reinforced Te on Seat 316 Stainless Disc Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 24 Type of end tting ANSI 300 anges Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stainless steel RPTFE 17 4 PH stainless PTFE glass ba
83. 0 76 2 13 38 340 F07 F6150HDU 6 150 2 19 55 6 6 02 153 3 02 76 7 13 53 344 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 69 DRCX24 3 T DRCX B 24 3 T N4 H NEMA 2 NEMA 4 Actuators On Off Floating Point Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 4 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered 8 Control signal may be pulsed from either the Hot Source or Common Sink 24 VAC line 9 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 10 For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller Position feedback cannot be used with a Triac sink controller The actuator internal common reference is not compatible Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed li censed electrician or other individual who has be
84. 000 20000 16667 14286 12500 6250 5000 6250 5000 6250 4545 8 49751 29851 29851 24876 21322 18657 9328 7463 9328 7463 9328 6784 220 VAC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 48 SY Series Non Spring Return Actuator Current Draws 24V AC DC Model Torque Speed 90 Motor Power Run Start Lock SY1 35 15s 10W 0 6A 08A 1 4A SY2 90 15s 70W 3 0A 5 0A 13 0A SY3 150 22s 70W 3 0A 5 0A 13 0A SY4 400 16s 180W 6 0A 8 0A 30 0A SY5 500 22s 180W 6 5A 8 0A 30 0A 110V Model Torque Speed 90 Motor Power Run Start Lock SY1 35 15s 10W 0 5A 1 5A 0 6A SY2 90 15s 70W 1 0A 3 0A 1 8A SY3 150 22s 70W 1 0A 3 0A 1 8A SY4 400 16s 180W 1 3A 3 1A 3 6A SY5 500 22s 180W 1 5A 3 0A 3 6A SY6 650 28s 120W 1 8A 3 0A 3 6A SY7 1000 46s 120W 3 2A 12 0A 10 0A SY8 1500 46s 120W 4 0A 14 0A 10 0A SY9 2000 58s 180W 3 2A 12 0A 6 0A SY10 2500 58s 220W 4 0A 12 0A 6 0A SY11 3000 58s 250W 3 0A 10 0A 5 0A SY12 3500 58s 300W 4 0A 14 0A 5 0A 230V Model Torque Speed 90 Motor Power Run Start Lock SY1 35 15s 10W 0 3A 1 0A 0 5A SY2 90 15s 70W 0 5A 1 5A 0 9A SY3 150 22s 70W 0 5A 1 5A 0 9A SY4 400 16s 180W 0 6A 1 5A 1 8A SY5 500 22s 180W 0 7A 1 5A 1
85. 089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 37 Maximum Dimensions Inches Valve Size Cv 90 A B C D E BHC No of Holes Lug Bolt Operator Weight lbs kg Close Off PSI F650 150SHP 2 102 1 75 n a 10 90 9 50 n a 4 75 4 5 8 11 UNC HND05 18 8 2 ANSI Class 150 Limitations F665 150SHP 2 146 1 88 n a 10 90 9 50 n a 5 50 4 5 8 11 UNC 18 8 2 F680 150SHP 3 228 1 92 n a 10 90 10 50 n a 6 00 4 5 8 11 UNC HND06 20 9 1 F6100 150SHP 4 451 2 13 n a 10 90 11 10 n a 7 50 8 5 8 11 UNC 32 14 5 F6125 150SHP 5 714 2 25 n a 15 10 12 00 n a 8 50 8 3 4 10 UNC HND07 38 17 2 F6150 150SHP 6 1103 2 29 n a 15 00 11 30 n a 9 50 8 3 4 10 UNC 46 20 9 F6200 150SHP 8 2064 2 50 n a 24 10 12 40 n a 11 75 8 3 4 10 UNC HND08 59 26 8 Valve Size Cv 90 A B C D E BHC No of Holes Lug Bolt Operator Weight lbs kg Close Off PSI F650 150SHP 2 102 1 75 6 41 2 50 11 60 6 50 4 75 4 5 8 11 UNC GW10 25 11 3 ANSI Class 150 Limitations F665 150SHP 2 146 1 88 6 41 2 50 11 60 6 50 5 50 4 5 8 11 UNC 25 11 3 F680 150SHP 3 228 1 92 6 41 2 50 12 30 6 50 6 00 4 5 8 11 UNC GW11 28 12 7 F6100 150SHP 4 451 2 13 6 41 2 50 13 00 6 50 7 50 8 5 8 11 UNC 38 17 2 F6125 150SHP 5 714 2 25 6 41 2 50 14 30 6 50 8 50 8 3 4 10 UNC GW12 48 21 8 F6150
86. 0SHP 20 14420 216 865 2019 3634 5480 7931 10815 13987 14420 F6600 150SHP 24 22050 331 1323 3087 5557 8379 12128 16538 21389 22050 F6750 150SHP 30 34388 491 1965 4585 8253 12445 18012 24563 32750 34388 F6 Series 2 Way ANSI Class 150 Butter y Valve Reinforced Te on Seat 316 Stainless Disc O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 27 Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F650 150SHP 2 102 1 75 9 00 9 00 19 50 4 75 4 5 8 11 UNC 2 AF 150 Spring Return F665 150SHP 2 146 1 88 9 00 9 00 20 00 5 50 4 5 8 11 UNC 150 F680 150SHP 3 228 1 92 9 00 9 00 20 50 6 00 4 5 8 11 UNC 150 F6100 150SHP 4 451 2 13 9 00 9 00 21 00 7 50 8 5 8 11 UNC 150 F650 150SHP 2 102 1 75 9 00 9 00 19 50 4 75 4 5 8 11 UNC GK 285 Electronic Fail Safe F665 150SHP 2 146 1 88 9 00 9 00 20 00 5 50 4 5 8 11 UNC 285 F680 150SHP 3 228 1 92 9 00 9 00 20 50 6 00 4 5 8 11 UNC 285 F6100 150SHP 4 451 2 13 9 00 9 00 21 00 7 50 8 5 8 11 UNC 150 F6100 150SHP 4 451 2 13 9 00 9 00 21 00 7 50 8 5 8 11 UNC 2 GK 285 F650 150SHP 2 102 1 75 9 00 9 00 19 50 4 75 4 5 8 11 UNC GM 285 Non Spring
87. 0SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F7100 150SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 F750 300SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F765 300SHP 2 5 65 1 88 47 8 3 62 92 10 49 266 17 32 440 F780 300SHP 3 80 1 92 48 8 3 62 92 10 49 266 18 07 459 F7100 300SHP 4 100 2 13 54 1 3 62 92 10 49 266 18 80 478 Note Most F7 versions use dual actuators O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 89 GMCX B 24 3 T X1 N4 H NEMA 4 Actuators On Off Floating Point Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety pre
88. 0SHP 313 285 18 lbs 19 lbs 2 F665 150SHP 490 150 24 lbs 2 F665 150SHP 490 285 18 lbs 19 lbs 3 F680 150SHP 705 150 26 lbs 3 F680 150SHP 705 285 20 lbs 21 lbs 4 F6100 150SHP 1253 150 32 lbs 33 lbs 4 F6100 150SHP 1253 150 40 lbs 42 lbs 3 way 2 F750 150SHP 313 285 67 lbs 69 lbs 2 F765 150SHP 490 285 78 lbs 80 lbs 3 F780 150SHP 705 285 88 lbs 90 lbs 4 F7100 150SHP 1253 150 135 lbs 139 lbs SHP Series Butter y Valves Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limits COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY series actuators are NEMA 4X rated and include 2 auxiliary switches and a heater ACTUATOR NON SPRING RETURN SPRING RETURN ELECTRONIC FAIL SAFE Size Valve Max GPM COP GMB X 2 GMB X 2 AF GK 2 GK ANSI 300 2 way 2 F650 300SHP 313 150 24 lbs 2 F650 300SHP 313 285 18 lbs 19 lbs 2 F665 300SHP 490 150 24 lbs 2 F665 300SHP 490 285 18 lbs 19 lbs 3 F680 300SHP 705 150 30 lbs 3 F680 300SHP 705 285 24 lbs 25 lbs 4 F6100 300SHP 1253 150 31 lbs 32 lbs 4 F6100 300SHP 1253 285 39 lbs 3 way
89. 1 Power Supply Hot 120 VAC H 230 VAC L2 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Not Used Internal Use Only Internal Use Only Internal Use Only Internal Use Only Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal Control Signal SYx 230MFT Address Adaption PC Tool Service Jack SYx 120MFT L N Power Supply Com 120 VAC N 230 VAC L1 Power Supply Hot 120 VAC H 230 VAC L2 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Control Signal Not Used Internal Use Only Internal Use Only Internal Use Only Internal Use Only Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal Control Signal SYx 230MFT Address Adaption PC Tool Service Jack SYx 120MFT L N G PE G PE Actuator A Actuator B Y1 Y2 Y1 Y2 35 36 35 36 36 35 W552_2 Isolation relays are required in parallel applications The reason parallel applications need isolation relays is that the motor uses two sets of windings one for each direction When one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the m
90. 10 12 Feedback Signal 2 to 10 VDC 5 Floating Point control Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U Output 2 to 10 V CCW CW Master CCW CW Slave 24 VAC Transformer Line Volts Control Signal 2 to 10 VDC 3 5 Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U 5 Master_Slave Master Slave Dimensions with 3 Way Valve D B A C ZM0822 Valve Nominal Size Dimensions Inches mm Valve Body IN DN mm A B C D FLG F750HD HDU 2 50 11 26 286 10 49 266 10 49 266 18 94 481 F05 F765HD HDU 2 5 65 11 32 287 10 49 266 10 49 266 19 49 495 F05 F780HD HDU 3 80 11 36 288 10 49 266 10 49 266 19 73 501 F05 F7100HDU 4 100 11 58 294 10 49 266 10 49 266 20 47 520 F07 F7125HDU 5 125 11 62 295 10 49 266 10 49 266 20 99 533 F07 F7150HDU 6 150 11 70 297 10 49 266 10 49 266 21 53 547 F07 Note Most F7 versions use 2 actuators O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 92 O50904 02 12 Subject to change Belimo Aircontrols USA Inc NSV SY Battery Back Up System For Belimo SY Series Electric Actuators 2 Position or Modulating Provides Fail Safe Operation for SY Series Industrial Electric Actuators SY1 through SY12
91. 150HDU 6 2 19 9 00 9 00 22 56 9 50 50 F650 150SHP 2 1 75 9 00 9 00 20 03 4 75 285 F665 150SHP 2 1 88 9 00 9 00 20 53 5 50 285 F680 150SHP 3 1 92 9 00 9 00 21 03 6 00 285 F6100 150SHP 4 2 13 9 00 9 00 21 53 7 50 150 F650 300SHP 2 1 75 9 00 9 00 20 03 5 00 285 F665 300SHP 2 1 88 9 00 9 00 20 53 5 88 285 F680 300SHP 3 1 92 9 00 9 00 21 03 6 63 285 F6100 300SHP 4 2 13 9 00 9 00 21 53 7 88 150 F6100VIC 4 4 63 8 63 8 63 16 00 200 AM_GM_LineRevised Technical Data GKX24 MFT X1 Power supply 24VAC 20 50 60Hz 24VDC 10 Power consumption 12W 3W Transformer sizing 21VA class 2 power source Electrical connection 18 GA plenum rated cable conduit connector protected NEMA 2 IP54 3 ft 1m 10 ft 3m 16 ft 5m Overload protection electronic throughout 0 to 95 rotation Operation range Y 2 to 10 VDC 4 to 20mA default variable VDC PWM oating point on off Input impedance 100 k 0 1 mA 500 1500 PWM oating point on off Feedback output U 2 to 10VDC 0 5mA max VDC variable Angle of rotation max 95 adjustable with mechanical stop electronically variable Direction of rotation reversible with switch Fail safe position adjustable with dial or tool 0 to 100 in 10 increments Position indication re ective visual indicator snap on Manual override external push
92. 16528 24 600 F7600HD MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F750HD 2 115 06 3 7 15 27 44 70 105 115 F765HD 2 196 10 6 12 25 45 75 119 178 196 F780HD 3 302 20 9 18 39 70 116 183 275 302 F7100HD 4 600 30 17 36 78 139 230 364 546 600 F7125HD 5 1022 50 29 61 133 237 392 620 930 1022 F7150HD 6 1579 80 45 95 205 366 605 958 1437 1579 F7200HD 8 3136 2 89 188 408 727 1202 1903 2854 3136 F7250HD 10 5340 3 151 320 694 1237 2047 3240 4859 5340 F7300HD 12 8250 4 234 495 1072 1911 3062 5005 7507 8250 F7350HD 14 11917 6 338 715 1549 2761 4568 7230 10844 11917 F7400HD 16 16388 8 464 983 2130 3797 6282 9942 14913 16388 F7450HD 18 21705 11 615 1302 2822 5028 8320 13168 19752 21705 F7500HD 20 27908 14 791 1674 3628 6465 10698 16931 25396 27908 F7600HD 24 43116 22 1222 2587 5605 9989 16528 26157 39236 43116 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 14 F7 Series 3 Way HD Butter y Valve Resilient Seat 304 Stainless Disc Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F750HD 2 115 4 50 6 15 6 15 20 25 4 7
93. 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 Servicing maintenance free DKRX24 3 T DKRX B 24 3 T N4 H NEMA 2 NEMA 4 Actuators On Off Floating Point Dimensions with 2 Way Valve D B C A BHC DR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 7 34 186 6 77 172 15 47 393 F07 F6125HD 5 125 2 08 52 8 7 34 186 6 77 172 16 47 418 F07 F6150HDU 6 150 2 19 55 6 7 34 186 6 77 172 16 47 418 F07 Dimensions without Housing A B C D 8 82 224 6 77 172 DRC24A_TP_7LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 5 81 148 2 64 67 1 13 25 337 F07 F6125HD 5 125 2 08 52 8 5 81 148 2 64 67 1 14 25 362 F07 F6150HDU 6 150 2 19 55 6 5 81 148 2 64 67 1 14 25 362 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 65 DKRX24 3 T DKRX B 24 3 T N4 H NEMA 2 NEMA 4 Actuators On Off Floating Point On Off control Off l W399_10 Floating Point control Wiring Diagrams 1 Provide overload protection and disconnect as required 2 CAUTION Equipment Damage N
94. 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 Analog Signal Input Output Mains Power 120VAC A C Line Voltage RD X SA 161 24 BR BK WH RD X BK RD BK 1 U5 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 As outlined below Max Load 150VA K1 K2 L2 neutral L1 hot GND AC DC AC DC NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for multiple proportional SY series 110 VAC actuators Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control signal and will fail safe position together Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuators as shown Observe wire size rules for longer wire runs K1 and K2 must be supplied 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 100 O50904 02 12 Subject to change Belimo Aircontrols USA Inc AUTOMATION SYSTEM OR SWITCH NSV SY 11 FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G N CLOSE OPEN A8 H 110VAC M3 M2 CONTROL SIGNALS AND POWER SY 1 5 24 D 5A 250VAC MAX ACTUATOR 1 AUX SW TE
95. 2 wiring restrictions Transformer sizing SY actuator draw X 1 25 safety margin Ex SY2 24 requires 3 0A x 1 25 3 75A 3 75A X 24 VAC 90VA Transformer INSTALLATION NOTES Use of feedback is optional APPLICATION NOTES Recommended twisted shielded pair for control wiring Ground shielded wire at control panel chassis Tape back ground at actuator NOTES SY2 5 24MFT Each actuator should be powered by a single isolated control transformer 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Not Used Internal Use Only Internal Use Only Internal Use Only Internal Use Only Power Supply Com Power Supply Hot 24V AC DC Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal Control Signal SYx 24MFT PC Tool Service Jack 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Control Signal Not Used Internal Use Only Internal Use Only Internal Use Only Internal Use Only Power Supply Com Power Supply Hot 24V AC DC Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal Control Signal SYx 24MFT PC Tool Service Jack G PE G PE Actuator B Actuator A Addre
96. 220 VAC actuator Building mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 105 O50904 02 12 Subject to change Belimo Aircontrols USA Inc NSV SY Battery Back Up System Wiring Diagrams K1 COIL MUST MATCH SUPPLY VOLTAGE IN THIS SCENARIO ACTUATOR 1 WORKS OPPOSITE ACTUATOR 2 IN THIS EXAMPLE K1 IS A 4PDT RELAY NOTES Do NOT exceed total VA capacity AUTOMATION SYSTEM OR SWITCH Max Load 150VA NSV SY 21 of NSV SY backup system NOTE FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G L2 K1 B K1 CLOSE OPEN A8 L1 220VAC M3 M2 K1 A AUX SW TERMINALS CONTROL SIGNALS AND POWER SY 1 6 220 D 5A 250VAC MAX D 5A 250VAC MAX ACTUATOR 2 AUX SW TERMINALS OBSERVE POLARITY OF 5 Open to Hot to G 3 1 4 7 4 3 7 6 B A C 5 Open to Hot to G 3 1 4 6 7 3 4 7 B A C C F F D A E F E C A D F ACTUATOR 1 NSV SY 23 Max Load 300VA NSV SY 25 Max Load 500VA Wiring diagram for multiple on off SY series 220 VAC actuators
97. 2938 200 103 lbs 12 F6300HD 4230 200 122 lbs 14 F6350HD 5758 150 131 lbs 16 F6400HD 7520 150 197 lbs 18 F6450HD 9518 150 272 lbs 20 F6500HD 11750 150 241 lbs 24 F6600HD 16921 150 332 lbs 30 F6750HD 26438 150 833 lbs 3 WAY 2 F750HD 118 200 65 lbs 2 5 F765HD 184 200 77 lbs 3 F780HD 264 200 84 lbs 4 F7100HD 470 200 134 lbs 5 F7125HD 734 200 163 lbs 6 F7150HD 1058 200 197 lbs 8 F7200HD 1880 200 297 lbs 10 F7250HD 2938 200 452 lbs 12 F7300HD 4230 200 603 lbs 14 F7350HD 5758 150 785 lbs 16 F7400HD 7520 150 1140 lbs 18 F7450HD 9518 150 1408 lbs 20 F7500HD 11750 150 1599 lbs 24 F7600HD 16921 150 2419 lbs HD Series Butter y Valves Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limits COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY series actuators are NEMA 4X rated and include 2 auxiliary switches and a heater O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 6 Butter y Valve Selection Velocity Chart HDU HD VIC Ser
98. 30 10 90 36 00 SY6 200 SY6 and larger available in 110 220 VAC versions only SY maximum actuator ambient temperature is 150 F Application Notes 1 Valves are rated at 200 psi differential pressure in the closed position 2 2 way assemblies are furnished assembled and tested ready for installation 3 Dimension D allows for actuator removal without the need to remove the valve from the pipe 4 Belimo SY Series actuators are NEMA 4X rated 5 Provide support for the actuator if it is mounted at any angle other than 90 vertical 6 Installer is to use rigid type couplings for connecting the valve to the piping Pressure Drop psi 10 10 100 1000 10000 1 0 1 0 01 2 60 3 mm 2 1 2 73 0 mm amp 76 1 mm 3 88 9 mm 4 114 3 mm amp 108 0 mm 5 141 3 mm 133 0 mm amp 139 7 mm 6 168 3 mm amp 165 1 mm amp 159 0 mm 8 219 1 mm 10 273 0 mm 12 323 9 mm A D C B A D C 162 38 6 393 B 47 05 1 852 101 6 4 217 25 8 553 97 99 3 858 Flow Rate GPM Dimensions O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 18 200 psi 2 to 12 bubble tight shut off Long stem design allows for 2 insulation Completely assembled and tested ready for installation Application These valves are designed t
99. 30 61 92 122 153 184 214 245 3 44 88 132 176 220 264 308 353 4 78 157 235 313 392 470 548 627 5 122 245 367 490 612 734 857 979 6 176 352 529 705 881 1058 1234 1410 8 313 627 940 1253 1567 1880 2193 2507 10 490 979 1469 1958 2448 2738 3427 3917 12 705 1410 2115 2820 3525 4230 4935 5640 14 959 1919 2879 3838 4798 5758 6717 7677 16 1253 2507 3760 5013 6267 7520 8774 10027 18 1586 3173 4759 6345 7931 9518 11104 12690 20 1958 3917 5875 7834 9792 11750 13709 15668 24 2820 5640 8460 11280 14100 16921 19741 22561 30 4406 8813 13220 17625 22032 26438 30845 35251 It is not recommended to exceed 12 feet per second through resilient seat butter y valves Velocities greater than 12 fps may damage the valve liner and disc If the maximum recommended velocity is exceeded the valve may be damaged and or the torque increased potentially exceeding the actuators capacity D163 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 7 F6 Series 2 Way HDU Butter y Valve Resilient Seat 304 Stainless Disc Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed equal percentage Controllable ow range 82 Sizes 2 to 12 Type of end tting for use
100. 300psi and for dead end services to full working pressure All Vitaulic valves are supplied in grooved style body design Valve Design Features The valve features a patented seat design that assures full 360 sealing The pressure enhanced seat compresses to form a larger seating area as the pressure increases The seat design also contributes to low breakaway torque of the valve Valves have EPDM seats that are DL classi ed to ANSI NSF 61 The disc is ductile iron conforming to ASTM A 536 grade 65 45 12 with electrolysis nickel coating conforming to ASTM B 733 Stem is 416 stainless steel conforming to ASTM A 582 RECTANGULAR DRIVE R Positive rectangular drive eliminates P fastners in the ow stream Design f prevents replacement errors p STEM SEALS Prevents leakage of media ISO 5211 MOUNTING FLANGE Accepts ISO standard actuators 2 8 50 200 mm are ange size F07 10 12 250 300 mm are angge size F10 DRIVE HUB Designed to accept nearly all types of actuation THERMAL BARRIER T Reduces condensation on gear R operators when installed in chilled o water applications w GE SEAL CARTRIDG rtridge houses stem seals Patented seal ca STEM t proof design utilizing stainless steel Blowout SEAT S Patented pressure enhanced rubber P seat design s DISC D Electroless nickel coated ductile iron E Optional O Aluminum B
101. 4 H NEMA 4 Actuators On Off Floating Point Dimensions with 2 Way Valve D B C A BHC GR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F650HD HDU 2 50 1 65 41 9 10 49 266 3 62 92 18 94 481 F05 F665HD HDU 2 5 65 1 76 44 7 10 49 266 3 62 92 19 49 495 F05 F680HD HDU 3 80 1 78 45 2 10 49 266 3 62 92 19 73 501 F05 F6100HDU 4 100 2 05 52 1 10 49 266 3 62 92 20 47 520 F07 F6125HDU 5 125 2 14 54 4 10 49 266 3 62 92 20 99 533 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 85 GRCX B 24 3 T N4 H NEMA 4 Actuators On Off Floating Point Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 4 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered Meets cULus or UL and CSA requirements without the need of an electrical ground connection Use suitable exible metallic conduit or its equivalent with the conduit tting WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live el
102. 43 1 88 n a 10 90 9 50 n a 5 50 8 3 4 10 UNC 15 6 8 F680 300SHP 3 223 1 92 n a 10 90 10 50 n a 6 00 8 3 4 10 UNC HND06 21 9 5 F6100 300SHP 4 435 2 13 n a 10 90 11 10 n a 7 50 8 3 4 10 UNC 29 13 2 F6125 300SHP 5 688 2 25 n a 15 10 12 20 n a 8 50 8 3 4 10 UNC HND07 38 17 2 F6150 300SHP 6 1041 2 29 n a 24 10 11 30 n a 9 50 12 3 4 10 UNC 62 28 1 Valve Size Cv 90 A B C D E BHC No of Holes Lug Bolt Operator Weight lbs kg Close Off PSI F650 300SHP 2 100 1 75 6 50 2 50 11 60 6 50 4 75 8 5 8 11 UNC GW10 23 10 4 ANSI Class 300 Limitations F665 300SHP 2 143 1 88 6 50 2 50 11 60 6 50 5 50 8 3 4 10 UNC 23 10 4 F680 300SHP 3 223 1 92 6 50 2 50 12 30 6 50 6 00 8 3 4 10 UNC GW11 29 13 2 F6100 300SHP 4 435 2 13 6 50 2 50 13 10 6 50 7 50 8 3 4 10 UNC 35 15 9 F6125 300SHP 5 688 2 25 6 50 2 50 14 30 6 50 8 50 8 3 4 10 UNC GW12 41 18 6 F6150 300SHP 6 1041 2 29 6 50 2 50 14 80 6 50 9 50 12 3 4 10 UNC GW13 63 28 6 F6200 300SHP 8 1911 2 88 6 50 2 50 15 90 6 50 11 75 12 7 8 9 UNC GW14 93 42 2 F6250 300SHP 10 3194 3 25 9 23 4 40 19 60 12 50 14 25 16 1 8 UNC GW16 150 68 0 F6300 300SHP 12 4428 3 62 9 23 4 40 23 00 15 00 17 00 16 1 1 8 8 UNC GW18 230 104 3 F6350 300SHP 14 5702 4 62 15 23 4 40 30 40 12 50
103. 47 418 F07 Dimensions without Housing A B C D 8 82 224 6 77 172 DRC24A_TP_7LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F6100HD 4 100 2 05 52 1 5 81 148 2 64 67 1 13 25 337 F07 F6125HD 5 125 2 08 52 8 5 81 148 2 64 67 1 14 25 362 F07 F6150HDU 6 150 2 19 55 6 5 81 148 2 64 67 1 14 25 362 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 67 DKRX24 MFT T DKRX B 24 MFT T N4 H NEMA 2 NEMA 4 Actuators Multi Function Technology W538 VDC 4 20 mA W538 On Off control CCW CW Line Volts 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input 5 U Output 2 to 10V A B 2 9 8 10 12 Feedback Signal 2 to 10 VDC 5 Floating Point control Wiring Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered 8 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 9 Contact closures A amp B also can be triacs A amp B should both
104. 5 4 5 8 11 UNC AF 200 Spring Return F765HD 2 196 4 50 6 76 6 50 20 25 4 75 4 5 8 11 UNC 2 AF 200 F780HD 3 302 5 00 7 28 6 76 20 75 5 50 4 5 8 11 UNC 2 GM GK 200 Electronic Fail Safe F750HD 2 115 4 50 6 15 6 15 20 25 4 75 4 5 8 11 UNC SY2 200 Non Spring Return F765HD 2 196 5 00 6 76 6 76 20 75 5 50 4 5 8 11 UNC 200 F780HD 3 302 5 50 7 28 7 28 21 00 6 00 4 5 8 11 UNC 200 F7100HD 4 600 6 50 8 55 8 55 21 75 7 50 8 5 8 11 UNC 200 F7125HD 5 1022 7 50 9 64 9 64 22 25 8 50 8 3 4 10 UNC SY3 200 F7150HD 6 1579 8 00 10 19 10 19 22 75 9 50 8 3 4 10 UNC 200 F7200HD 8 3136 9 00 11 37 11 37 29 00 11 75 8 3 4 10 UNC SY4 200 F7250HD 10 5340 11 00 13 58 13 58 30 00 14 25 12 7 8 9 UNC 200 F7300HD 12 8250 12 00 15 01 15 01 32 00 17 00 12 7 8 9 UNC SY5 200 F7350HD 14 11917 14 00 17 02 17 02 33 00 18 75 12 1 8 UNC SY6 150 F7400HD 16 16388 15 00 18 39 18 39 38 50 21 25 16 1 8 UNC SY7 150 F7450HD 18 21705 16 50 20 63 20 63 39 50 22 75 16 1 1 8 7 UNC SY9 150 F7500HD 20 27908 18 00 23 00 23 00 41 50 25 00 20 1 1 8 7 UNC 150 F7600HD 24 43116 22 00 27 9 27 9 53 25 29 50 20 1 1 4 7 UNC SY12 150 AF maximum actuator ambient temperature is 122 F SY maximum actuator ambient temperatur
105. 5340 3 151 320 694 1237 2047 3240 4859 5340 F7300HDU 12 8250 4 234 495 1072 1911 3062 5005 7507 8250 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 10 F7 Series 3 Way HDU Butter y Valve Resilient Seat 304 Stainless Disc Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F750HDU 2 115 4 50 6 15 6 15 15 50 4 75 4 5 8 11 UNC AF 50 Spring Return F765HDU 2 196 5 00 6 76 6 76 16 00 5 50 4 5 8 11 UNC 2 AF 50 F780HDU 3 302 5 50 7 28 7 28 16 25 6 00 4 5 8 11 UNC 50 F780HDU 3 302 5 50 7 28 7 28 21 00 6 00 4 5 8 11 UNC GK 50 Electronic Fail Safe F7100HDU 4 600 6 50 8 55 8 55 21 75 7 50 8 5 8 11 UNC 2 GK 50 F7125HDU 5 1022 7 50 9 64 9 64 22 25 8 50 8 3 4 10 UNC 50 F7150HDU 6 1579 8 00 10 19 10 19 22 75 9 50 8 3 4 10 UNC 50 F750HDU 2 115 4 50 6 65 6 15 15 50 4 75 4 5 8 11 UNC AR 50 Non Spring Return F765HDU 2 196 5 00 6 76 6 76 16 00 5 50 4 5 8 11 UNC 50 F780HDU 3 302 5 50 7 28 7 28 21 00 6 00 4 5 8 11 UNC GM 50 F7100HDU 4 600 6 50 8 54 8 54 21 75 7 50 8 5 8 11 UNC 2 GM 50 F7125HDU 5 1022 7 50 9 64 9 64 22 25 8 50 8 3 4 10 UNC 50 F7150HDU 6 15
106. 5HD 2 5 00 6 76 6 76 16 00 5 50 200 F765HDU 2 5 00 6 76 6 76 16 00 5 50 50 F780HDU 3 5 50 7 28 7 28 16 25 6 00 50 F750VIC 2 4 50 6 85 6 85 15 00 50 F750VIC 2 4 50 6 85 6 85 15 00 200 F765VIC 2 5 00 7 46 7 46 15 00 50 HS DWGP11 Technical Data Power supply 24 VAC 20 50 60 Hz 24 VDC 20 10 Power running 7 5 W consumption holding 3 W Transformer sizing 10 VA Class 2 power source Electrical connection AFX 3 ft 1m default 10 ft 3m or 16 ft 5m 18 GA appliance or plenum cables with or without 1 2 conduit connector S models two 3 ft 1m default 10 ft 3m or 16 ft 5m appliance cables with or without 1 2 conduit connectors Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC 4 to 20 mA default variable VDC PWM floating point on off Input impedance 100 k for 2 to 10 VDC 0 1 mA 500 for 4 to 20 mA 1500 for PWM floating point and on off control Feedback output U 2 to 10 VDC 0 5 mA max Torque minimum 180 in lb 20 Nm Direction of spring reversible with cw ccw mounting rotation motor reversible with built in switch Mechanical angle of rotation 95 adjustable with mechanical end stop 35 to 95 Running time spring lt 20 sec 4 F to 122 F 20 C to 50 C lt 60 sec 22 F 30 C motor 150 seconds default variable
107. 6 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 118 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Every effort is made to provide accurate information but no liability for claims arising from erroneous data will be accepted by Belimo Installation Recommendations SHP Series Butter y Valves FLANGE BOLTING RECOMMENDATIONS Lug Valves 2 30 ANSI 125 150 Bolt Pattern STUDS amp NUTS MACHINE BOLTS Valve Size Thread Size C QTY LENGTH D QTY LENGTH F QTY LENGTH G QTY LENGTH 2 5 8 11 4 2 50 4 2 50 4 1 63 4 1 63 2 1 2 5 8 11 4 2 75 4 2 75 4 1 85 4 1 85 3 5 8 11 4 3 25 4 2 50 4 2 25 4 1 63 4 5 8 11 8 3 00 8 2 75 8 2 12 8 1 88 5 3 4 10 8 3 00 8 3 00 8 2 00 8 2 00 6 3 4 10 8 3 50 8 3 00 8 2 50 8 1 88 8 3 4 10 8 3 75 8 3 25 8 2 70 8 2 13 10 7 8 9 12 4 25 12 3 50 12 3 00 12 2 25 12 7 8 9 12 4 75 12 3 50 12 3 45 12 2 35 14 1 8 12 5 00 12 4 00 12 3 75 12 2 70 16 1 8 16 5 50 16 4 25 16 4 12 16 2 75 18 1 1 8 8 16 5 75 16 4 75 16 4 38 16 3 25 20 1 1 8 8 16 6 75 16 4 75 16 5 12 16 3 25 1 1 8 8 4 5 50 4 4 75 4 4 12 4 3 25 24 1 1 4 8 20 7 25 20 5 75 20 5 63 20 4 25 30 1 1 4 8 24 7 75 24 7 75 24 6 25 24 6 25 1 1 4 8 4 6 50 4 6 25 4 5 00 4 4 63 LUG BODY HEX HEAD
108. 6 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 53 Each actuator should be powered by a single isolated control transformer wiring to a common is prohibited Terminals 4 and 6 need to be wired separately SY Actuator Wiring Diagram SY1 24P and SY1 110P 220P Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment CAUTION may result in minor or moderate injury It may also be used to alert against unsafe practices this manual Read these carefully Hazard Identification 33 33 INSTALLATION NOTES Use of feedback is optional APPLICATION NOTES 36 34 Ground shielded wire at control panel chassis Tape back ground at actuator NOTES SY1 24P 24V AC DC Transformer Line Voltage G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback Feedback Control signal G SY1 24P A B C E F LS4 LS3 G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback 120 or 230 VAC N L1 H L2 SY1 110P 220P A B C E F LS4 LS3 NOTES SY1 110P 220P Caution wiring to a common
109. 78 118 157 196 235 274 313 353 2 61 122 184 245 306 367 428 490 551 3 88 176 264 353 441 529 617 705 793 4 157 313 470 627 783 940 1097 1253 1410 5 245 490 734 979 1224 1469 1714 1958 2203 6 352 705 1058 1410 1763 2115 2468 2820 3173 8 627 1253 1880 2507 3133 3760 4387 5013 5640 10 979 1958 2938 3917 4896 5875 6854 7834 8813 12 1410 2820 4230 5640 7050 8460 9870 11280 12690 14 1919 3838 5738 7677 9596 11515 13435 15354 17273 16 2507 5013 7520 10027 12534 15040 17547 20054 22561 18 3173 6345 9518 12690 15863 19036 22208 25381 28553 20 3917 7834 11750 15667 19584 23501 27418 31334 35251 24 5640 11280 16921 22561 28201 33841 39481 45121 50762 30 8813 17625 26438 35251 44064 52877 61689 70502 79315 It is not recommended to exceed 32 feet per second through high performance butterfly valves Velocities greater than 32 fps may damage the valve D145 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 26 Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 30 Type of end tting for use with ASME class 125 150 ange
110. 79 8 00 10 19 10 19 22 75 9 50 8 3 4 10 UNC 50 F750HDU 2 115 4 50 6 15 6 15 15 50 4 75 4 5 8 11 UNC SY1 50 F765HDU 2 196 5 00 6 76 6 76 16 00 5 50 4 5 8 11 UNC 50 F780HDU 3 302 5 50 7 28 7 28 21 00 6 00 4 5 8 11 UNC SY2 50 F7100HDU 4 600 6 50 8 55 8 55 21 75 7 50 8 5 8 11 UNC 50 F7125HDU 5 1022 7 50 9 64 9 64 22 25 8 50 8 3 4 10 UNC 50 F7150HDU 6 1579 8 00 10 19 10 19 22 75 9 50 8 3 4 10 UNC 50 F7200HDU 8 3136 9 00 11 37 11 37 24 25 11 75 8 3 4 10 UNC SY3 50 F7250HDU 10 5340 11 00 13 58 13 58 30 00 14 25 12 7 8 9 UNC SY4 50 F7300HDU 12 8250 12 00 15 01 15 01 32 00 17 00 12 7 8 9 UNC 50 AF maximum actuator ambient temperature is 122 F SY maximum actuator ambient temperature is 150 F Model SY1 does not have hand wheel override is via 8mm wrench on bottom side of actuator Application Notes 1 Valves are rated at 50 psi differential pressure in the closed position 2 Valves are furnished with lugs tapped for use with ANSI Class 125 150 anges Installation anges and hardware are not included 3 3 way assemblies are furnished assembled and tested ready for installation All 3 way assemblies require the customer to specify the 3 way con guration prior to order entry to guarantee correct placement of valves and actuators on the assembly 4 Dimension D allows fo
111. 8 11 UNC SY2 50 F6125HDU 5 1022 392 2 19 8 00 13 00 22 50 8 50 8 3 4 10 UNC 50 F6150HDU 6 1579 605 2 19 8 00 13 00 23 00 9 50 8 3 4 10 UNC 50 F6200HDU 8 3136 1202 2 37 8 00 13 00 24 25 11 75 8 3 4 10 UNC SY3 50 F6250HDU 10 5340 2047 2 67 8 00 13 00 25 50 14 25 12 7 8 9 UNC 50 F6300HDU 12 8250 3062 3 01 8 00 13 00 27 25 17 00 12 7 8 9 UNC SY4 50 Dimension A is compressed add 125 for relaxed state AF AM and GM maximum actuator ambient temperature is 122 F SY maximum actuator ambient temperature is 150 F Model SY1 does not have handwheel override is via 8mm wrench on bottom side of actuator Application Notes 1 Valves are rated at 50 psi differential pressure in the closed position 2 Valves are furnished with lugs tapped for use with ANSI Class 125 150 anges Installation anges and hardware are not included 3 2 way assemblies are furnished assembled and tested ready for installation 4 Dimension D allows for actuator removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data upon request 6 Dual actuated valves have actuators mounted on a common valve shaft 7 Belimo SY Series actuators are NEMA 4X rated Dimensions D B C A Flow Pattern 0 10 20 10 30 50 40 60 80 70 90 20 30 40 60 50 70 80 100 90 100 OF
112. 8 UNC SY8 285 SY9 400 SY11 600 SY8 150 F6500 300SHP 20 10658 6 31 14 00 14 00 49 50 27 00 24 1 1 4 8 UNC SY10 285 SY11 400 F6600 300SHP 24 16205 7 19 14 00 14 00 56 25 32 00 24 1 1 2 8 UNC SY10 150 F6 Series 2 Way ANSI Class 300 Butter y Valve Reinforced Te on Seat 316 Stainless Disc Dimensions D102 Dimension A does not include ange gaskets 2 required per valve Application Notes 1 Valves are rated at 725 psi differential pressure in the closed position 100 F media temperature 2 Valves are furnished with lugs tapped for use between ANSI Class 250 300 anges conforming to ANSI B16 5 Standards 3 2 way assemblies are furnished assembled calibrated and tested ready for installation 4 Dimension D allows for actuator s removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data furnished upon request 6 Dual actuated valves have actuators mounted on a single common shaft 7 Flange gaskets 2 required not provided with valve MUST be used between valve and ANSI ange 8 Flange bolts are not included with the valve These are furnished by others g y D B C A BHC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 32 Bubble tight shut off to ANSI Class
113. 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 1 Butter y Valves BFV Application A comprehensive line of Butter y Valves is available in sizes ranging from 2 to 30 in both standard and high performance Victaulic valves are available to 12 All Butter y Valves ful ll the commercial and industrial HVAC application requirement for positive shut off for liquids Applications Include Chillers Isolation Cooling Tower Isolation Change Over Systems Large Air Handlers Coil Controls Bypass and Related Process Control Standard grooved and high performance Butter y Valves meet a wide range of commercial and industrial HVAC applications Advanced seat and disc designs provide bubble tight shut off capability at each valves speci ed temperature and pressure while maintaining a low seating torque Belimo offers NEMA 2 NEMA 4 and NEMA 4X actuators to ensure control in a variety of environments Standard HD HDU series valves incorporate a ve bushing design to isolate the valve shaft from the body for better control Stainless steel or nickel plated discs are standard for superior strength and durability ensuring a long lasting operation Grooved valves are AWWA rated for potable water in the United States Check local laws for Canada O50904 02 12 Subject to change Belimo Aircontrols USA
114. 88 15 25 1 12 16 1 12 20 50 2 00 17 75 1 25 16 1 1 8 14 23 00 2 12 20 25 1 25 20 1 1 8 16 25 50 2 25 22 50 1 37 20 1 1 4 18 28 00 2 38 24 75 1 37 24 1 1 4 20 30 50 2 50 27 00 1 37 24 1 1 4 24 36 00 2 75 32 00 1 62 24 1 1 2 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 120 O50904 02 12 Subject to change Belimo Aircontrols USA Inc ZS BFV Series Dimension Drawings 12 00 12 00 4 00 0 10 ZS BFV 10 ZS BFV 20 ZS BFV 30 X1 12 00 12 00 12 00 10 10 0 12 00 ZS BFV 30 X2 ZS BFV 100 X2 9 00 18 00 16 00 ZS BFV 60 ZS BFV 70 ZS BFV 80 ZS BFV 90 9 00 18 00 16 00 10 10 1 0
115. 8A SY6 650 28s 120W 0 8A 1 5A 1 8A SY7 1000 46s 120W 1 6A 4 0A 4 00A SY8 1500 46s 120W 2 0A 3 6A 5 0A SY9 2000 58s 180W 1 6A 5 0A 4 0A SY10 2500 58s 220W 2 0A 4 0A 3 0A SY11 3000 58s 250W 1 6A 4 0A 3 0A SY12 3500 58s 300W 2 2A 4 0A 3 0A RUN normal operation START initial current draw LOCK power to the actuator but the motor is not moving O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 49 INSTALLATION NOTES CAUTION Notes 1 Motor CAMS have been factory calibrated and should not be moved 2 An adaption must be performed if any limit switch is adjusted This will calibrate the beginning and end stopping points Press the adaption button for 3 seconds and release 3 New SY actuators must have an adaption performed before operation Control Signal Control Signal FDBK FDBK Adaption Direction of Rotation PC Tool Service Jack Connection 24V Control Signal Control Signal FDBK FDBK Adaption A Direction of Rotation N H 120 230V Actuators SYx MFT PC Tool Service Jack Power Supply Common Power Supply Hot Power Supply Com Power Supply Hot Interface Wiring Detail SYx MFT 24V 120 230V O50904 02 12 Subj
116. 9 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 75 GK Actuators Multi Function Technology WARNING Live Electrical Components G During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury W399_Butterfly VDC 4 20 mA W399_Butterfly PWMM W399_Butterfly On Off control Off l W399_Butterfly Floating Point control Wiring Diagrams 1 Provide overload protection and disconnect as required 3 Actuators may also be powered by 24 VDC 4 Position feedback cannot be used with Triac sink controller The actuator internal common reference is not compatible 5 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 8 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 9 For triac sink the common connection from the actuator must be connected to the hot connection of the controller Meets UL requirements without the need of an electrical ground connection The ZG R01 500 resistor may be used NOTE Wiring diagrams shown are for single actuator m
117. 988 5438 7850 8243 F6450 300SHP 18 9712 139 555 1295 2331 3515 5088 6938 9250 9712 F6500 300SHP 20 10658 158 630 1470 2646 3990 5775 7875 10150 10658 F6600 300SHP 24 16205 242 966 2254 4057 6118 8855 12075 16100 16205 F6 Series 2 Way ANSI Class 300 Butter y Valve Reinforced PTFE Seat 316 Stainless Disc with Manual Handle or Gear Wheel Operator Technical Data Service chilled hot water 60 glycol steam to 50 psi Flow characteristic modi ed equal percentage unidirectional Controllable ow range 82 Sizes 2 to 24 Type of end tting ANSI 300 anges Materials Body Disc Seat Shaft Gland seal Bushings carbon steel full lug 316 stainless steel RPTFE 17 4 PH stainless PTFE glass backed PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 300 Close off pressure 740 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 39 Maximum Dimensions Inches Valve Size Cv 90 A B C D E BHC No of Holes Lug Bolt Operator Weight lbs kg Close Off PSI F650 300SHP 2 100 1 75 n a 10 90 9 50 n a 4 75 8 5 8 11 UNC HND05 15 6 8 ANSI Class 300 Limitations F665 300SHP 2 1
118. AC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication NOTES SY1 24P Each actuator should be powered by a single isolated control transformer SY1 24P notes Power supply Com Neutral and Control Signal wiring to a common is prohibited Terminals 4 and 6 need to be wired separately otherwise irreversible damage will occur Do not change sensitivity or dip switch settings with power applied G G 35 36 33 35 36 35 36 W550_11 Wiring for Control Valves Proportional 24V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 57 Actuators SY2 5 24MFT Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 5 24MFT Observe class 1 and class
119. C 2 VDC 4mA Master Valve Closed Spring Fails Master Valve OPEN NC FC Normally Closed Fail Closed 1 VDC 2 VDC 4mA Closed Spring Fails Valve CLOSED NC FC Normally Closed Fail Closed 1 VDC 2 VDC 4mA Master Valve Closed Spring Fails Master Valve CLOSED 2 1 Choose the valve actuator combination NO F650HD SY2 24MFT Tagging if needed Specify preference or con guration Does order require tagging 4 Set Up 5 Complete Ordering Example F650HD SY2 24MFT NO ACE Consult factory 2 way Preference 3 way Con guration Tagging Valves may be tagged per customer speci cation 10 00 per tag Example Chiller 1 3rd Floor East Part number for tagging 99981 00101 For MFT orders only select programming code consult factory 3 ORDERING EXAMPLE O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 3 Features Bene ts Standard Performance Butter y Valves VALVE DESIGN FEATURES Unique seat and disc design ensures positive valve sealing while maintaining low seating torque Butterfly valve discs are precision machined to half ball profile providing a precise disc to seat relationship Cartridge style seat incorporates an elastomer bonded to a phenolic stabilizing ring eliminating elastomer movement and reducing seat tearing or fatiguing due to bunching
120. CONFIG CODE CLOSED NON FAIL OPEN CLOSED MASTER FAIL VALVE VALVE IS MASTER M D 15 CLOSED CLOSED NON FAIL NON FAIL CLOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER NON FAIL NON FAIL CLOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER MOD 2VDC ON OFF OR CLOSED CLOSED CLOSED OPEN OPEN OPEN CLOSED CLOSED CLOSED OPEN OPEN OPEN ON OFF OR MOD 2VDC MASTER VALVE IS ON OFF OR MOD 2VDC MASTER VALVE IS MASTER SLAVE COMMON FLOW FLOW MASTER SLAVE COMMON MASTER SLAVE FLOW COMMON MASTER COMMON FLOW SLAVE MASTER SLAVE COMMON FLOW MIXING DIVERTING M D 24 M D 25 M D 23 M D 22 M D 21 M D 20 M D 34 M D 35 M D 33 M D 32 M D 31 M D 30 M Specifies MIXING D Specifies DIVERTING Notes 1 Slave Valve operates inversely of the Master Valve 2 The Master Valve is always located on the run 3 The Slave Valve may also have an actuator if required Direct Coupled 4 On Off actuator normal position is a function of field logic 5 Proportional actuator normal position is a function of the CCW CW swit 6 All 3 way assemblies are designed for 90 degree actuator rotation Flow in Std Weight Pipe Fluid Velocity in GPM Use with SHP Series BF Valves SIZE 4 FPS 8 FPS 12 FPS 16 FPS 20 FPS 24 FPS 28 FPS 32 FPS 36 FPS 2 39
121. CW CW Master CCW CW Slave 24 VAC Transformer Line Volts Control Signal 2 to 10 VDC 3 5 Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U 5 Master_Slave Master Slave O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 64 Models DKRX24 3 T w terminal block DKRX24 3 T N4 w terminal block DKRB24 3 T N4H w heater Technical Data Control on off oating point Power supply 24 VAC 20 10 50 60 Hz Power consumption running 12W heater 33W holding 3W Transformer sizing 21 VA class 2 power source heater 36 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance 100 at control input 1500 oating point Angle of rotation 90 Position indication visual pointer N4 Manual override internal push button UL Type 4 external push buttom UL Type 2 Running time 150 seconds default Fail Safe 35 seconds Humidity 5 to 100 RH UL Type 4 5 to 95 RH non condensation UL Type 2 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 UL Type 2 NEMA 2 IP54 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730
122. Diagrams 2 CAUTION Equipment damage Actuators may be connected in parallel Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 5 Actuators with plenum rated cable do not have numbers on wires use color codes instead Actuators with appliance cables are numbered 8 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 9 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink 10 For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller Position feedback cannot be used with a Triac sink controller The actuator internal common reference is not compatible 12 IN4004 or IN4007 diode IN4007 supplied Belimo part number 40155 The ZG R01 500 resistor converts the 4 to 20 mA control signal to 2 to 10 VDC up to 2 actuators may be connected in parallel WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury WARNING M
123. Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control switch and will fail safe position together Building mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 106 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Wiring Diagrams Wiring diagram for a single proportional SY series 220 VAC actuator Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 107 O50904 02 12 Subject to change Belimo Aircontrols USA Inc K1 A K1 B K2 B K2 A NSV SY 12 G N H A5 A2 A6 M2 M3 AG RD X SA 161 24 BR BK WH RD X OUT IN BK RD BK 1 U5 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 Analog Signa
124. F6400 300SHP 20054 150 603 lbs 18 F6450 300SHP 25381 400 647 lbs 18 F6450 300SHP 25381 600 647 lbs 18 F6450 300SHP 25381 150 821 lbs 20 F6500 300SHP 31334 285 865 lbs 20 F6500 300SHP 31334 400 865 lbs 24 F6600 300SHP 45121 150 1150 lbs O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 24 Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limits COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY series actuators are NEMA 4X rated and include 2 auxiliary switches and a heater SHP Series Butter y Valves with Industrial Actuation Average Assembly Weights ACTUATOR NON SPRING RETURN Size Valve Model Max GPM COP SY2 110 SY3 110 SY4 110 SY5 110 SY7 110 SY8 110 SY9 110 SY10 110 SY11 110 SY 12 110 ANSI 300 3 way 2 F750 300SHP 313 400 104 lbs 2 F750 300SHP 313 600 104 lbs 2 F765 300SHP 490 400 124 lbs 2 F765 300SHP 490 600 124 lbs 3 F780 300SHP 705 400 147 lbs 3 F780 300SHP 705 600 147 lbs 4 F7100 300SHP 1253 285 222 lbs 4 F7100 300SHP 1253 600 222 lbs 5 F7125 300SHP 1958
125. F650HDU 118 50 13 lbs 14 lbs 2 5 F665HDU 184 50 13 lbs 14 lbs 3 F680HDU 264 50 13 lbs 25 lbs 4 F6100HDU 470 50 24 lbs 34 lbs 25 lbs 5 F6125HDU 734 50 29 lbs 39 lbs 30 lbs 6 F6150HDU 1058 50 43 lbs 45 lbs 3 WAY 2 F750HDU 118 50 44 lbs 46 lbs 2 5 F765HDU 184 50 56 lbs 65 lbs 3 F780HDU 264 50 62 lbs 72 lbs 63 lbs 4 F7100HDU 470 50 122 lbs 124 lbs 5 F7125HDU 734 50 152 lbs 154 lbs 6 F7150HDU 1058 50 186 lbs 188 lbs NON SPRING RETURN SPRING RETURN ELECTRONIC FAIL SAFE Size Valve Max GPM COP AMB X GMB X 2 GMB X AF 2 AF GK 2 GK FULL RATED MODELS 2 WAY 2 F650HD 118 200 13 lbs 14 lbs 2 5 F665HD 184 200 13 lbs 24 lbs 161 lbs 32 lbs 3 F680HD 264 200 15 lbs 25 lbs 4 F6100HD 470 200 30 lbs 3 WAY 2 F750HD 118 200 44 lbs 46 lbs 2 5 F765HD 184 200 55 lbs 65 lbs 56 lbs 3 F780HD 264 200 72 lbs 74 lbs 4 F7100HD 470 200 122 lbs 124 lbs HD U Series Butter y Valves Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limits COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY se
126. F780 150SHP 705 285 103 lbs 4 F7100 150SHP 1253 285 162 lbs 5 F7125 150SHP 1958 285 195 lbs 6 F7150 150SHP 2820 285 234 lbs 8 F7200 150SHP 5013 285 355 lbs 10 F7250 150SHP 7834 150 585 lbs 10 F7250 150SHP 7834 285 585 lbs 12 F7300 150SHP 11280 150 785 lbs 12 F7300 150SHP 11280 285 819 lbs 14 F7350 150SHP 15354 285 1118 lbs 16 F7400 150SHP 20054 150 1469 lbs 1523 lbs 18 F7450 150SHP 25381 150 1783 lbs 18 F7450 150SHP 25381 285 1831 lbs 20 F7500 150SHP 31334 150 2351 lbs 20 F7500 150SHP 31334 285 2351 lbs 24 F7600 150SHP 45121 150 3722 lbs SHP Series Butter y Valves with Industrial Actuation Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limits COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY series actuators are NEMA 4X rated and include 2 auxiliary switches and a heater O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 23 Max GPM Maximum US gallons of water gpm per minute at room temperature that will flow through the fully open valve without exceeding design velocity limit
127. HD 3 302 0 2 9 18 39 70 116 183 275 302 F6100HD 4 600 0 3 17 36 78 139 230 364 546 600 F6125HD 5 1022 0 5 29 61 133 237 392 620 930 1022 F6150HD 6 1579 0 8 45 95 205 366 605 958 1437 1579 F6200HD 8 3136 2 89 188 408 727 1202 1903 2854 3136 F6250HD 10 5340 3 151 320 694 1237 2047 3240 4859 5340 F6300HD 12 8250 4 234 495 1072 1911 3062 5005 7507 8250 F6350HD 14 11917 6 338 715 1549 2761 4568 7230 10844 11917 F6400HD 16 16388 8 464 983 2130 3797 6282 9942 14913 16388 F6450HD 18 21705 11 615 1302 2822 5028 8320 13168 19752 21705 F6500HD 20 27908 14 791 1674 3628 6465 10698 16931 25396 27908 F6600HD 24 43116 22 1222 2587 5605 9989 16528 26157 39236 43116 F6750HD 30 73426 37 2081 4405 9545 17011 28146 44545 66818 73426 F6 Series 2 Way HD Butter y Valve Resilient Seat 304 Stainless Disc with Manual Handle or Gear Wheel Operator Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed equal percentage Controllable ow range 82 Sizes 2 to 30 Type of end tting for use with ANSI 125 150 anges Materials Body Body nish Disc Seat Shaft O ring Bushings ductile iron ASTM A536 epoxy powder coated 304 stainless steel EPDM standard 416 stainless steel EPDM RPTFE Media temperature range 22 F t
128. Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 2 Nomenclature Butter y Valves BFV F6 HD SY2 24 MFT Valve F6 2 way F7 3 way Valve Size 50 2 65 2 1 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 750 30 Trim Material HDU Stainless Disc Cast Ductile Iron Full Lug Body EPDM Liner Bubble Tight Close Off to 50 psi HD Stainless Disc Cast Ductile Iron Full Lug Body EPDM Liner Bubble Tight Close Off to 200 psi 2 to 12 150 psi 14 150SHP ANSI Class 150 Stainless Disc Cast Steel Full Lug Body RPTFE Seat Bubble Tight Close off up to 285 psi 300SHP ANSI Class 300 Stainless Disc Cast Steel Full Lug Body RPTFE Seat Bubble Tight Close off up to 600 psi VIC Grooved AWWA C606 Nickel Coated Iron Disc Cast Ductile Iron ASTM A536 Grooved Fitting EPDM Seat Bubble Tight Close Off to 200 psi Actuator Type Non Spring Return ARB X GRB X DR N4 GR GM N4 GMB X SY Electronic Fail Safe GK DKR N4 Spring Return AF Power Supply 24 24 VAC DC 110 110 120 VAC 120 120 VAC 230 230 VAC UP 24 240 VAC Control Blank On Off 3 X1 On Off Floating Point MFT or MFT X1 Multi Function Technology S Built in Auxiliary Switch X1 Water Con guration Non Spring Retu
129. LOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER MOD 2VDC ON OFF OR CLOSED CLOSED CLOSED OPEN OPEN OPEN CLOSED CLOSED CLOSED OPEN OPEN OPEN ON OFF OR MOD 2VDC MASTER VALVE IS ON OFF OR MOD 2VDC MASTER VALVE IS X24 X25 X23 X22 X21 X20 X34 X35 X33 X32 X31 X30 X Specifies Bi Directional Flow Capability MASTER COMMON SLAVE MASTER SLAVE COMMON MASTER MASTER SLAVE SLAVE COMMON COMMON NOTES 1 Slave Valve operates inversely of the Master Valve 2 The Master Valve is always located on the run 3 The Slave Valve may also have an actuator if required Direct Coupled 4 On Off actuator normal position is a function of eld logic 5 Proportional actuator normal position is a function of the CCW CW switch 6 All 3 way assemblies are designed for 90 degree actuator rotation ORDERING INFORMATION Please note that HD series BF valves over 18 and ALL sizes 3 way tee assemblies ordered with Configuration Codes 30 35 are special order custom 5 built and are NOT returnable T O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 15 Features and Bene ts VIC Victaulic Butter y Valves Belimo VIC Series Victaulic Butter y Valves are designed for pressure ranging from vacuum to
130. N Actuators may be connected in parallel if not mechanically mounted to the same shaft Power consumption and input impedance must be observed 3 Actuators may also be powered by 24 VDC 4 Position feedback cannot be used with Triac sink controller The actuator internal common reference is not compatible 5 Control signal may be pulsed from either the Hot source or the Common sink 24 VAC line 8 Contact closures A amp B also can be triacs A amp B should both be closed for triac source and open for triac sink GMX B 24 MFT T N4 H NEMA 4 Actuators Multi Function Technology 9 For triac sink the common connection from the actuator must be connected to the hot connection of the controller The ZG R01 500 resistor may be used WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury W399_08 VDC 4 20 mA W399_08 PWM W399_08 On Off control CCW CW Line Volts 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input 5 U Output 2 to 10V A B 2 9 8
131. On Off j y 24 VAC Transformer Blk 1 Common Red 2 Wht 3 Line Volts The indication of direction is valid for switch position 1 2 3 5 GMB24 3 X1 1 0 W559 Floating Point Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GM 2 GM F765HD 2 5 00 6 70 6 70 16 00 5 50 200 F780HD 3 5 50 7 20 7 20 16 25 6 00 200 F780HDU 3 5 50 7 20 7 20 16 25 6 00 50 F7100HDU 4 6 50 8 45 8 45 17 00 7 50 50 F7125HDU 5 7 50 9 60 9 60 17 50 8 50 50 F7150HDU 6 8 00 10 08 10 08 18 00 9 50 50 F750 150SHP 2 4 50 6 25 6 25 16 50 4 75 150 285 F765 150SHP 2 5 00 6 88 6 88 17 00 5 50 150 285 F780 150SHP 3 5 50 7 42 7 42 17 50 6 00 150 285 F7100 150SHP 4 6 50 8 63 8 63 18 00 7 50 150 F750 300SHP 2 5 00 6 75 6 75 15 50 5 00 285 F765 300SHP 2 5 50 7 38 7 38 16 00 5 88 285 F780 300SHP 3 6 00 7 92 7 92 16 25 6 63 285 F7100 300SHP 4 7 00 9 13 9 13 18 00 7 88 150 F750VIC 2 5 00 6 70 6 70 15 50 50 F765VIC 2 5 25 7 25 7 25 15 50 200 F780VIC 3 6 00 7 25 7 25 16 00 50 Dimensions with 3 Way Valve 10 0 10 0 D A B C D101 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 82 Models
132. RMINALS Opened to Closed to OBSERVE POLARITY OF 5 Close to Open to Hot to G 3 1 4 7 4 3 7 6 B A C C F F A E NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for a single on off SY series 24 VAC actuator Building mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs The 24vac transformer required to run the SYxxx 24 actuator is built in to the NSV cabinet 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 101 O50904 02 12 Subject to change Belimo Aircontrols USA Inc K1 COIL MUST MATCH SUPPLY VOLTAGE IN THIS SCENARIO ACTUATOR 1 WORKS OPPOSITE ACTUATOR 2 IN THIS EXAMPLE K1 IS A 4PDT RELAY NOTES Do NOT exceed total VA capacity AUTOMATION SYSTEM OR SWITCH Max Load 150VA NSV SY 11 of NSV SY backup system NOTE FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G N K1 B K1 CLOSE OPEN A8 H 110VAC M3 M2 K1 A AUX SW TERMINALS CONTROL SIGNALS AND POWER SY 1 5 24 D Opened to Closed to 5A 250VAC MAX D 5A 250VAC MAX ACTUATOR 2 AUX SW TERMINALS Opened to Closed
133. Return F665 150SHP 2 146 1 88 9 00 9 00 20 00 5 50 4 5 8 11 UNC 285 F680 150SHP 3 228 1 92 9 00 9 00 20 50 6 00 4 5 8 11 UNC 285 F6100 150SHP 4 451 2 13 9 00 9 00 21 00 7 50 8 5 8 11 UNC 150 F6100 150SHP 4 451 2 13 9 00 9 00 21 00 7 50 8 5 8 11 UNC 2 GM 285 F650 150SHP 2 102 1 75 8 00 8 00 22 25 4 75 4 5 8 11 UNC SY2 285 F665 150SHP 2 146 1 88 8 00 8 00 22 75 5 50 4 5 8 11 UNC 285 F680 150SHP 3 228 1 92 8 00 8 00 23 00 6 00 4 5 8 11 UNC 285 F6100 150SHP 4 451 2 13 8 00 8 00 23 75 7 50 8 5 8 11 UNC 285 F6125 150SHP 5 714 2 25 8 00 8 00 24 25 8 50 8 3 4 10 UNC 285 F6150 150SHP 6 1103 2 29 8 00 8 00 24 75 9 50 8 3 4 10 UNC 285 F6200 150SHP 8 2064 2 50 12 00 12 00 32 00 11 75 8 3 4 10 UNC SY3 150 SY4 285 F6250 150SHP 10 3517 2 81 12 00 12 00 33 00 14 25 12 7 8 9 UNC SY4 285 F6300 150SHP 12 4837 3 23 12 00 12 00 35 00 17 00 12 7 8 9 UNC SY4 150 SY5 285 F6350 150SHP 14 6857 3 62 14 00 14 00 36 00 18 75 12 1 8 UNC SY5 150 SY7 285 150 F6400 150SHP 16 9287 4 00 14 00 14 00 37 50 21 25 16 1 8 UNC SY8 285 F6450 150SHP 18 11400 4 50 14 00 14 00 42 25 22 75 16 1 1 8 8 UNC SY7 150 SY8 285 F6500 150SHP 20 14420 5 00 14 00 14 00 49 50 25 00 20 1 1 8 8 UNC SY8 15
134. SELECT switch is irrelevant Power is supplied through the interface cabinet and the actuator heater is enabled No current is being drawn from the battery system during this mode of operation When the mains power is lost charging power is no longer supplied to the battery system and the green LINE IN indicator light is turned off The battery system automatically generates modi ed sine wave line voltage to provide power for the actuator The blue BAT CHARGING indicator light is turned off and the yellow B U POWER indicator light is turned on The FAIL POSITION SELECT switch becomes active and depending on its position drives the actuator either fully open or fully closed During this mode of operation the heater is NOT energized and the position of any eld interface switching is irrelevant The battery system will provide ample power to drive the actuator more than 5 full torque cycles However once the actuator reaches its end of travel limit switch power drain from the back up system is reduced to the requirements of the yellow B U POWER indicator light After 15 minutes the battery system turns itself off and waits for the mains power to return The gear train design of the SY actuator provides automatic locking of the actuator position after the battery system shuts down Normal operation is resumed when mains power returns 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 94
135. SY3 220 MFT 1335 22 0 5 NSV SY 21 NSV SY 22 36 1 0 RBC2 SY4 220 MFT 3560 16 0 6 NSV SY 21 NSV SY 22 22 1 2 RBC2 SY5 220 MFT 4450 22 0 7 NSV SY 21 NSV SY 22 19 1 9 RBC2 SY6 220 MFT 5785 28 0 8 NSV SY 21 NSV SY 22 17 2 7 RBC2 SY7 220 MFT 8900 46 1 6 NSV SY 23 NSV SY 24 6 12 8 RBC32 SY8 220 MFT 13350 46 2 0 NSV SY 23 NSV SY 24 4 19 2 RBC32 SY9 220 MFT 17800 58 1 6 NSV SY 23 NSV SY 24 6 16 1 RBC32 SY10 220 MFT 22250 58 2 0 NSV SY 25 NSV SY 26 18 5 4 RBC32 SY11 220 MFT 36700 58 1 6 NSV SY 25 NSV SY 26 26 3 7 RBC32 SY12 220 MFT 31150 58 2 2 NSV SY 25 NSV SY 26 15 6 4 RBC32 NSV SY Battery Back Up System For Belimo SY Series Electric Actuators 2 Position or Modulating 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 96 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Wiring diagram for a single on off SY series 110 VAC actuator AUTOMATION SYSTEM OR SWITCH NSV SY 05 NSV SY 03 NSV SY 01 FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G N CLOSE OPEN A8 H 110VAC M3 M2 SY 1 12 110 D 5A 250VAC MAX ACTUATOR 1 AUX SW TERMINALS Opened to Closed to 5 Close to Open to Hot to G 3 1 4 7 4 3 7 6 B A C C F F E NSV SY Battery Back Up System Wiring Diagrams Buildi
136. Shaft Design g g Using a punch approximately the same size as the wedge pins drive each pin out of the disc hub from the non peened side of the disc to the peened side of the disc b For Split Shaft Design p g Pull the wedge pins out of the disc hub using the threaded holes on top of each pin and a jack screw 5 Support the valve body and disc on a at surface in the horizontal position Slowly remove shaft s 6 Remove the disc from the body 7 To remove bearings cut or grind a slot lengthwise in each bearing in order to be able to collapse bearing prior to removal Be careful not to damage bearing seating bore within the body 8 Clean all components thoroughly 9 Inspect all parts for damage prior to reassembly Damaged parts should be repaired or replaced with new parts 10 Carefully clean and polish the disc sealing surface with a soft cloth The disc sealing surface should be free of all grooves and scratches 11 Install the new bearings by gently tapping them into the body with a soft rod and hammer The bearings should be installed into the shaft bore rmly against the counterbore or bottom of shaft hole 12 a Valves 2 through 12 g With the valve body on the edge of the bench shaft horizontal and the body overtravel stop nearest to the bench position the disc in the open position with the at face upward Present the disc to the valve body from the side opposite the seat retainer cavity
137. Soft Seat is designed for high services with minimal wear and low torque Seat replacement is a simple operation requiring no special tools Valve Body is Full Lug type cast in Carbon Steel Disc is cast in CF8M Stainless Steel Shaft is 17 4pH Stainless for superior strength Soft Seat is RPTFE for increased wear resistance and low torque Top Mounted Gland Flange easily accessible without removing actuator or mounting brackets WEDGE PINS Provide positive mechanical attachment of disc to shaft SOFT SEAT Patented bidirectional seat with encapsulated elastomeric o ring core for resiliency Common seat materials include TFE RTFE and UHMWPE OVERTRAVEL STOP Prevents disc from rotating into wrong quadrant SET SCREWS Cone point screws force wedge ring outward to lock seat retainer in position on valve sizes 2 through 30 Socket head cap screws are used on valve sizes 36 and larger WEDGE RING Stainless steel band wedged between valve body and retainer ring by set screws to lock seat and retainer ring in position on valve sizes 2 through 30 Socket head cap screws are used on valve sizes 36 and larger PACKING Chevron design TFE prevents external leakage out valve neck to full ANSI hydrostatic shell test pressures 150 of C W P GLAND FLANGE Applies load against packing gland to prevent external leakage Fully adjustable KEY Square key valve to operator connection provide
138. Storage of Butterfly Valve Assemblies Assemblies must be stored indoors protected from the elements Materials received on job sites that have long installation lead times should receive extra protection from construction damage Resilient seats must be protected from abrasion cutting and nick ing as this will damage the liner and may cause flange area leaks Electric actuators cannot be stored in wet damp or caustic areas Do not store construction material on top of valve assemblies Installation Practices HD U series butterfly valves are designed to be installed between ANSI 125 150 flat faced raised face slip on or weld neck flanges Valve should be installed a minimum of 10 pipe diameters from upstream or downstream elbows strainers pumps etc For chilled water condenser water or hot water applications the valve should be installed with the stem in a vertical orientation with the actuator mounted above the valve For applications in which there is a possibility of sediment in the flow the valve should be installed with the stem in a horizontal position and the bottom of the disc should close FROM the down stream side rather than from the upstream side Make sure the flange faces are clean and free of rust scale and debris to prevent damage to the liner face Do NOT use flange gaskets on HD U series BF valves Fig 1a Follow the recommended fla
139. Valves are capable of bubble tight dead end closure with either the upstream or downstream flange removed F6 150SHP 30SHP F7 150SHP 300SHP Series Butter y Valves General Maintenance The following periodic preventative maintenance practices are recommended for all Butterfly Valves 1 Operate the valve from full open to full closed to assure operability 2 Check flange bolting actuator mounts and hangers for evidence of loosening and correct as needed 3 Inspect the valve and surrounding area for previous or existing leakage at flange faces or shaft connections 4 Check piping and or wiring to actuators and related equipment for looseness and correct as needed 5 If not in use exercise the butterfly valve full open and close at least once a month 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 115 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Valve Design 1 The SHP Series High Performance Butterfly Valve features a double offset or double eccentric shaft design to minimize seat abrasion and lower torque This double offset design allows the disc to lift off and cam away from the seat as it rotates open 2 The SHP valve always rotates clockwise to close when viewed from above and counterclockwise to open 3 The valve body has an Overtravel Stop which prevents the disc from over rotating into the wrong quadrant This stop is not to be u
140. agnetic field created from the first It s called back EMF This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow it has no magnetic effect on the motor On parallel applications without isolation this EMF voltage energizes the winding it is connected to on the other actuators in the system the actuators are then trying to turn in both directions at once The EMF voltage is always less than the supply voltage due to the resistance of the windings so while the actuator still turns in the commanded direction the drag from the other reduces the torque output and causes overheating Wiring for Control Valves Proportional Multiple Wiring 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 60 Models AFBUP X1 AFRBUP 5 AFBUP S X1 AFRXUP AFXUP X1 AFRBUP S 5 AFXUP S X1 AFRXUP S Dimensions with 2 Way Valve A B C D BHC BF2WUDIM_A Dimensions Inches Fail Safe psi Valve Size A B C D Max BHC AF 2 AF F650HD 2 1 65 9 00 9 00 19 50 4 75 200 F650HDU 2 1 65 9 00 9 00 19 50 4 75 50 F665HD 2 1 76 9 00 9 00 20 00 5 50 200 F665HDU 2 1 76 9 00 9 00 20 00 5 50 50 F680HD 3 1 78 9 00 9 00 20 50 6 00 200 F680HDU 3 1 78 9 00 9 00 20 50 6 00 50 F6100HDU 4 2
141. agrams 3 Actuators may also be powered by 24 VDC 4 IN4004 or IN4007 diode IN4007 supplied Belimo part number 40155 5 Triac A and B can also be contact closures 6 Control signal may be pulsed from either the Hot Source or Common Sink 24 VAC line 7 Position feedback cannot be used with Triac sink controller The actuators internal common reference is not compatible The ZG R01 500 resistor converts the 4 to 20 mA control signal to 2 to 10 VDC up to 2 actuators may be connected in parallel Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury AF Actuators Multi Function Technology W399_Butterfly VDC 4 20 mA W399_Butterfly PWMM W399_Butterfly On Off control Off l W399_Butterfly Floating Point control AFB24 MFT S AFX24 MFT S Auxiliary Switches for AFX24 MFT S X1 W600_AFB_AFX 1 AFX24 MFT S X1 Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U Output 2 to 10 V C
142. al Technical Speci cations Input Nominal input voltage 120 V Input frequency 50 60 Hz 3 Hz auto sensing Input Connection Type NEMA 5 15P Cord Length 6 feet Input voltage range for main operations 88 139 V Output Output power capacity 900 VA Output power capacity 540 Watts Nominal output voltage 120 V Waveform type Stepped approximation to a sinewave Output Connections 7 NEMA 5 15R Batteries Typical backup time at half load 17 6 minutes Battery type Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof Typical recharge time 8 hour s Replacement battery cartridge 1 RBC32 Communications amp Management Control panel LED status display with On Line On Battery Replace Battery and Overload indicators Audible alarm Alarm when on battery distinctive low battery alarm overload continuous tone alarm Surge Protection and Filtering Surge energy rating 320 joules Filtering Full time multi pole noise ltering 5 IEEE surge let through zero clamping response time meets UL 1449 Dataline protection RJ 11 Modem Fax DSL protection two wire single line plus RJ 45 ethernet The time to recharge to 90 of full battery capacity following a discharge to shutdown using a load rated for 1 2 the full load rating of the UPS 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 110 O50904 02 12 Subject to change Belimo Aircontrols USA Inc
143. allation Tees comply with ASME ANSI B16 1 Class 125 anges Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Designed for use in Victaulic piping systems when mated to Victaulic 41 series ange nipples Fail safe operation is possible with NSV SY series battery backup systems Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F7 HD Butter y Valves Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN DN mm 2 way Spring Non Spring Electronic Fail Safe 115 44 2 50 F750HD AF Series AM SY Series 196 75 2 65 F765HD 302 116 3 80 F780HD GM GK 600 230 4 100 F7100HD 1022 392 5 125 F7125HD 1579 605 6 150 F7150HD 3136 1202 8 200 F7200HD 5340 2047 10 250 F7250HD 8250 3062 12 300 F7300HD 11917 4568 14 350 F7350HD 16388 6282 16 400 F7400HD 21705 8320 18 450 F7450HD 27908 10698 20 500 F7500HD 43116
144. and tested ready for installation Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications Designed for use in Victaulic piping systems when mated to Victaulic 41 series ange nipples Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F6 HD Butter y Valves Valve Nominal Size Type Manual Operators Cv 90 Cv 60 IN DN mm 2 way 115 44 2 50 F650HD Handle Gear Wheel OP 196 75 2 65 F665HD 302 116 3 80 F680HD 600 230 4 100 F6100HD 1022 392 5 125 F6125HD 1579 605 6 150 F6150HD 3136 1202 8 200 F6200HD 5340 2047 10 250 F6250HD 8250 3062 12 300 F6300HD 11917 4568 14 350 F6350HD 16388 6282 16 400 F6400HD 21705 8320 18 450 F6450HD 27908 10698 20 500 F6500HD 43116 16528 24 600 F6600HD 73426 28146 30 750 F6750HD Valve Size Cv 10 20 30 40 50 60 70 80 90 F650HD 2 115 0 06 3 7 15 27 44 70 105 115 F665HD 2 196 0 1 6 12 25 45 75 119 178 196 F680
145. andards 3 2 way assemblies are furnished assembled and ready for installation 4 Flange gaskets 2 required not provided with valve MUST be used between valve and ANSI ange 5 Flange bolts are not included with the valve These are furnished by others Belimo AutoCAD_Gear F6 Series 2 Way ANSI Class 150 Butter y Valve Reinforced PTFE Seat 316 Stainless Disc with Manual Handle or Gear Wheel Operator O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 38 Bubble tight shut off to ANSI Class 300 Standards Long stem design allows for 2 insulation minimum Valve face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI B16 5 Flanges Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F6 SHP 300 Butter y Valves Valve Nominal
146. ard and high performance valve series these actuators are available for on off and modulating applications Depending on the application they are available in 24 VAC VDC 120 VAC and 230 VAC Technical Data Electrical connection conduit connector screw terminals Motor protection H Class insulation SY 1 F Class SY 2 5 Gear train high alloy steel gear sets self locking Operating range SY 24 on off floating point SY 24MFT 2 10 VDC 4 20 mA 0 10 VDC Sensitivity SY 24MFT 0 4 mA 200mV Reversal hysteresis SY 24MFT 1 0 mA 500mV Feedback SY 24MFT 2 10 VDC Angle of rotation 90 Direction of rotation reversible Position indication top mounted domed indicator Internal humidity control resistive heating element Auxiliary switches factory set for 5 and 85 change of state SY1 2 SPDT min 1 mA 24 VAC max 3A 250 VAC SY2 12 2 SPDT min 1 mA 24 VAC max 5A 250 VAC Ambient temperature 22 F to 150 F 30 C to 65 C Humidity range up to 95 Housing type IP67 NEMA 4X Housing material die cast aluminum alloy Agency listings ISO CE cCSAus Power Supply 24 VAC VDC 50 60Hz single phase Model Torque Speed Power Consumption Duty Cycle Override Weight On Off MFT SY1 24 P 35Nm 310 in lbs 15s 1 8A 30 75 8mm Wrench 2 0kg 4 9 lb SY2 24 MFT 90Nm 801 in lbs 15s 3 0A 30 75 Hand Wheel 11kg 24 5 lb SY3 24 MFT 150Nm
147. ax DSL protection two wire single line 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 109 O50904 02 12 Subject to change Belimo Aircontrols USA Inc PHYSICAL DIMENSIONS NSV SY Series Back Up Systems NSV NSV SY NSV SY Maximum Dimensions 01 02 21 22 03 04 11 12 23 24 05 06 25 26 Height 13 13 15 Width 22 22 22 Depth 5 5 5 Net weight 36 42 44 Shipping Weight 38 44 48 Environmental Operating Relative Humidity 0 95 Operating Elevation 0 10000 feet 0 3000 m Storage Temperature 15 45 C 5 113 F Storage Relative Humidity 0 95 Storage Elevation 0 50000 feet 0 15000 m Audible noise at 1 meter from surface of unit 45 dBA Online thermal dissipation 24 BTU hr Conformance APC Back UP Module Approvals CSA FCC B UL 1778 Approvals FCC Part 15 Class B Industry Canada UL 1778 cUL Listed Battery Back Up System For Powered Belimo SY Series Electric Actuators 2 Position or Modulating BACK UPS 900VA PART NUMBER BR900 Availability North America Latin America Product Overview Description APC Back UPS 900VA 540W Input 120V Output 120V General Features Audible Alarms Automatic Voltage Regulation AVR Easy Overload Recovery Ethernet Protection Hot Swap Batteries Modem Protection Overload Indicator Replace Batt Indicator Site wiring fault indicator User Replaceable batteries Documentation User Manu
148. be closed for triac source and open for triac sink 10 For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller Position feedback cannot be used with a Triac sink controller The actuator internal common reference is not compatible 12 IN4004 or IN4007 diode IN4007 supplied Belimo part number 40155 The ZG R01 500 resistor converts the 4 to 20 mA control signal to 2 to 10 VDC up to 2 actuators may be connected in parallel WARNING Live Electrical Components During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 68 Models DRCX24 3 T w terminal block DRCX24 3 T N4 w terminal block DRCB24 3 T N4H w heater Technical Data Control on off oating point Power supply 24 VAC 20 10 50 60 Hz 24 VDC 10 Power consumption running 9W heater 29W holding 2W Transformer sizing 12 VA class 2 power source heater 27 VA Electrical connection
149. cautions when exposed to live electrical components could result in death or serious injury 2 3 5 24 VAC Transformer a open a closed Blk 1 Common Red 2 Wht 3 a Line Volts The indication of direction is valid for switch position 1 GMB24 3 X1 1 0 W559 On Off j y 24 VAC Transformer Blk 1 Common Red 2 Wht 3 Line Volts The indication of direction is valid for switch position 1 2 3 5 GMB24 3 X1 1 0 W559 Floating Point Dimensions with 3 Way Valve D B A C ZM0822 Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F750HD HDU 2 50 1 65 41 9 10 49 266 3 62 92 18 94 481 F05 F765HD HDU 2 5 65 1 76 44 7 10 49 266 3 62 92 19 49 495 F05 F780HD HDU 3 80 1 78 45 2 10 49 266 3 62 92 19 73 501 F05 F7100HDU 4 100 2 05 52 1 10 49 266 3 62 92 20 47 520 F07 F7125HDU 5 125 2 14 54 4 10 49 266 3 62 92 20 99 533 F07 F7150HDU 6 150 2 19 55 6 10 49 266 3 62 92 21 53 547 F07 Note Most F7 versions use 2 actuators O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 90 Models GMX24 MFT T X1 N4 w terminal block GMB24 MFT T X1 N4H w heater Technical Data Control 2 to 10 VDC 4 to 20 mA default variable VDC oating point on off P
150. ciated equipment Equipment damage Power consumption and input impedance must be observed Isolation relays are required in parallel applications The reason parallel applications need isolation relays is that the motor uses two sets of windings one for each direction When one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first It s called back EMF This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow it has no magnetic effect on the motor On parallel applications without isolation this EMF voltage energizes the winding it is connected to on the other actuators in the system the actuators are then trying to turn in both directions at once The EMF voltage is always less than the supply voltage due to the resistance of the windings so while the actuator still turns in the commanded direction the drag from the other reduces the torque output and causes overheating CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification INSTALLATION NOTES G Ground 1 Common 3 Open 4 Closed 5 6 7 HTR A B C D E F LS3
151. cked PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 300 Close off pressure 740 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 31 Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F650 300SHP 2 100 1 75 9 00 9 00 19 50 5 00 8 5 8 11 UNC 2 AF 150 Spring Return F665 300SHP 2 143 1 88 9 00 9 00 20 00 5 88 8 3 4 10 UNC 150 F680 300SHP 3 223 1 92 9 00 9 00 20 50 6 63 8 3 4 10 UNC 150 F6100 300SHP 4 435 2 13 9 00 9 00 21 00 7 88 8 3 4 10 UNC 150 F650 300SHP 2 100 1 75 9 00 9 00 19 50 5 00 8 5 8 11 UNC GK 150 Electronic Fail Safe F665 300SHP 2 143 1 88 9 00 9 00 20 00 5 88 8 3 4 10 UNC 150 F680 300SHP 3 223 1 92 9 00 9 00 20 50 6 63 8 3 4 10 UNC 150 F6100 300SHP 4 435 2 13 9 00 9 00 21 00 7 88 8 3 4 10 UNC 150 F650 300SHP 2 100 1 75 9 00 9 00 19 50 5 00 8 5 8 11 UNC 2 GK 400 F665 300SHP 2 143 1 88 9 00 9 00 20 00 5 88 8 3 4 10 UNC 400 F680 300SHP 3 223 1 92 9 00 9 00 20 50 6 63 8 3 4 10 UNC 400 F650 300SHP 2 100 1 75 9 00 9 00 19 50 5 00 8
152. ction Technology Models AFX24 MFT X1 AFX24 MFT S X1 w built in Aux Switches 2 AFX24 MFT X1 2 AFX24 MFT S X1 Dimensions Inches Fail Safe psi i Valve Size A B C D Max BHC AF 2 AF F650HD 2 1 65 9 00 9 00 19 50 4 75 200 F650HDU 2 1 65 9 00 9 00 19 50 4 75 50 F665HD 2 1 76 9 00 9 00 20 00 5 50 200 F665HDU 2 1 76 9 00 9 00 20 00 5 50 50 F680HD 3 1 78 9 00 9 00 20 50 6 00 50 F680HDU 3 1 78 9 00 9 00 20 50 6 00 50 F6100HDU 4 2 05 9 00 9 00 21 00 7 50 50 F6125HDU 5 2 14 9 00 9 00 22 00 8 50 50 F650 150SHP 2 1 75 9 00 9 00 19 50 4 75 150 F665 150SHP 2 1 88 9 00 9 00 20 00 5 50 150 F680 150SHP 3 1 92 9 00 9 00 20 50 6 00 150 F6100 150SHP 4 2 13 9 00 9 00 21 00 7 50 150 F650 300SHP 2 1 75 9 00 9 00 19 50 5 00 150 F665 300SHP 2 1 88 9 00 9 00 20 00 5 88 150 F680 300SHP 3 1 92 9 00 9 00 20 50 6 63 150 F6100 300SHP 4 2 13 9 00 9 00 21 00 7 88 150 F650VIC 2 3 21 8 60 8 60 18 25 200 F665VIC 2 3 77 8 60 8 60 18 70 200 F680VIC 3 3 77 8 60 8 60 18 70 50 Dimensions with 3 Way Valve 10 10 D A B C Dimensions Inches Fail Safe psi Valve Size A B C D Max BHC AF 2 AF F750HD 2 4 50 6 15 6 15 15 50 4 75 200 F750HDU 2 4 50 6 15 6 15 15 50 4 75 50 F76
153. d Wheel 56kg 123 5 lb SY12 120 MFT 3500Nm 31150 in lbs 58s 70s 4 0A 30 50 Hand Wheel 56kg 123 5 lb SY 120V Series Non Spring Return Actuator Technical Data 120 VAC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 45 Application The SY actuators are NEMA 4X rated and designed to meet the needs of HVAC and Commercial applications Offered on Belimo standard and high performance valve series these actuators are available for on off and modulating applications Depending on the application they are available in 24 VAC VDC 120 VAC and 230 VAC Power Supply 230 VAC 50 60Hz single phase Model Torque Speed 60Hz Speed 50Hz Power Consumption Duty Cycle Override Weight On Off MFT SY1 220 P 35Nm 310 in lbs 12s 13s 0 3A 30 75 8mm Wrench 2 0kg 4 9 lb SY2 230 MFT 90Nm 801 in lbs 15s 17s 0 5A 30 75 Hand Wheel 11kg 24 5 lb SY3 230 MFT 150Nm 1335 in lbs 22s 26s 0 5A 30 75 Hand Wheel 11kg 24 5 lb SY4 230 MFT 400Nm 3560 in lbs 16s 18s 0 6A 30 75 Hand Wheel 22kg 48 5 lb SY5 230 MFT 500Nm 4450 in lbs 22s 25s 0 7A 30 75 Hand Wheel 22kg 48 5 lb SY6 230 MFT 650Nm 5785 in lbs 28s 31s 0 8A 30 75 Hand Wheel 22kg 48 5 lb SY7 230 MFT 1000Nm 8900 in lbs 46s 55s 1 6A 30 75 Hand Wheel 36kg 79 5 lb SY8 230 MFT 1500Nm 13350 in lbs 46
154. d shielded wire at control panel chassis Tape back ground at actuator Observe class 1 and class 2 wiring restrictions INSTALLATION NOTES G G 35 36 35 36 35 36 W552_1_11 Proportional 110 220V 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 59 Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment Equipment damage Power consumption and input impedance must be observed CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification A B C D E F LS3 A C Open Indication LS4 D F Closed Indication Contact Rating 5A 250 VAC Max SY2 12 120MFT SY2 12 230MFT Actuators SY2 12 120MFT SY2 12 230MFT NOTES SY2 12 120MFT 230MFT Caution Power supply voltage Use of feedback is optional APPLICATION NOTES Recommended twisted shielded pair for control wiring Ground shielded wire at control panel chassis Tape back ground at actuator Observe class 1 and class 2 wiring restrictions INSTALLATION NOTES Power Supply Com 120 VAC N 230 VAC L
155. djust warranty voided LS2 Clockwise Decrease Closed Angle CLOSE Counter clockwise Increase Closed Angle LS1 Clockwise Increase Opening Angle OPEN Counter clockwise Decrease Opening Angle Factory pre set and calibrated Do not adjust warranty voided LS4 LS3 LS2 LS1 WARNING Electrical Travel Adjustment Factory Pre set SY 1 CAUTION SY 2 12 Electrical Travel Adjustment CAUTION Notes 1 An adaption must be performed when the limit switches are adjusted For the SYx MFT actuators This will calibrate the beginning and end stopping points Press the adaption button for 3 seconds and release CAUTION INSTALLATION NOTES SY Series Non Spring Return Actuator O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 52 SY Actuator Wiring Diagram SY1 5 24V On Off SY1 12 120V or 230V On Off Observe class 1 and class 2 wiring restrictions Transformer sizing SY actuator draw X 1 25 safety margin Ex SY2 24 requires 3 0A x 1 25 3 75A 3 75A X 24 VAC 90VA Transformer Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment Equipment damage Power consumption and input impedance must be observed CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may
156. e is 150 F SY6 and larger available in 110 220 VAC versions only Application Notes 1 Valves are rated at 200 psi differential pressure in the closed position 2 Valves are furnished with lugs tapped for use with ANSI Class 125 150 anges Installation anges and hardware are not included 3 3 way assemblies are furnished assembled and tested ready for installation All 3 way assemblies require the customer to specify the 3 way con guration prior to order entry to guarantee correct placement of valves and actuators on the assembly 4 Dimension D allows for actuator removal without the need to remove the valve from the pipe 5 Belimo SY Series actuators are NEMA 4X rated 5 Weather shields are available dimensional data upon request 6 Dual actuated valves have single actuators mounted on each valve shaft 7 Bolts supplied are for shipping purposes only Upon installation replace with an appropriate SAE grade 5 or better hardware Note For tee con guration please refer to page 4 Dimensions 10 0 10 0 D A B C HS DWG11 3 Way Con guration Codes D163 NON FAIL OPEN OPEN OPEN CLOSED OPEN X11 X12 X10 X13 X14 CONFIG CODE CLOSED NON FAIL OPEN CLOSED MASTER FAIL VALVE VALVE IS MASTER X15 CLOSED CLOSED NON FAIL NON FAIL CLOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER NON FAIL NON FAIL C
157. e shaft in the horizontal position All SHP valves are bidirectional and can be mounted in the pipeline in either ow direction however the preferred ow direction for all seat styles and materials is with the seat retainer ring located upstream sus to provide maximum seat protection For SHP Series valves a Noting the ow direction arrow on the tag place the valve between the anges making sure the arrow on the tag points in the direction of the ow b Install the lower ange bolts loosely leaving space for the ange gaskets c After inserting the ange gaskets install the remaining bolts 3 Using the sequence shown to the right tighten the ange bolts evenly to assure uniform gasket compression CAUTION The SHP valve should be centered between the anges and gaskets to prevent damage to the disc edge and shaft as a result of the disc striking the ange gasket or pipe 4 Electricity should be connected to the unit as speci ed by the actuator manufacturer 5 The valve is now ready for operation NOTE Actuator must be mounted at or above pipe center line for all actuator types 90 90 Installation Recommendations SHP Series Butter y Valves Fig 8 3 1 2 4 1 4 3 2 5 6 7 8 9 10 11 12 13 14 15 16 1 4 3 2 5 6 7 8 9 10 11 12 1 4 3 2 5 6 7 8 800 543 9038 USA 86
158. echanical Precautions The mechanical end stops cannot be moved or repositioned Doing so will adversely effect the operation of the valve The directional switch cannot be moved Maintain Factory Settings GRX B 24 MFT T N4 H NEMA 4 Actuators Multi Function Technology W538 On Off control CCW CW Line Volts 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input 5 U Output 2 to 10V A B 2 9 8 10 12 Feedback Signal 2 to 10 VDC 5 Floating Point W538 VDC 4 20 mA MFT MFT O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 88 Models GMCX24 3 T X1 N4 w terminal block GMCB24 3 T X1 N4H w heater Technical Data Control on off oating point Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 8W heater 28W holding 2 5W Transformer sizing 11 VA class 2 power source heater 26 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 95 rotation Input impedance 1000 at control input Angle of rotation 95 adjustable with mechanical stop electronically variable Direction of rotation reversible with Position indication visual pointer Manual override internal push button UL Type 4 Running time 35 seconds default Humidity 5 to 100
159. ect to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 50 Interface Wiring Detail SYx P Potentiometer Factory Pre set For 2 position actuators with 1k feedback option Potentiometer points 1 2 3 are wired to terminal blocks 8 9 10 When a valve is closed 8 9 1k 9 10 0k When a valve is opened 8 9 0k 9 10 1k For modulating actuators with 1k feedback option Potentiometer points 1 2 3 are wired to terminal blocks 8 9 10 When a valve is closed 8 9 1k 9 10 0k When a valve is opened 8 9 0k 9 10 1k INPUT 2 10 VDC INPUT 4 20mA INPUT 1 5 VDC OUTPUT 2 10 VDC OUTPUT 4 20mA LOSS OF SIGNAL STOP RESPONSE REVERSE RESPONSE DIRECT LOSS OF SIGNAL CLOSED Direct Acting LOSS OF SIGNAL OPEN Reverse Acting LOSS OF SIGNAL OPEN Direct Acting LOSS OF SIGNAL CLOSED Reverse Acting ON ON OFF ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON OFF ON 1 2 3 4 5 6 7 8 6 7 8 2 3 5 4 1 8 7 6 2 5 3 4 1 8 7 6 2 5 3 4 1 8 7 6 2 5 3 4 1 6 7 8 2 3 5 4 1 8 7 6 2 4 5 3 1 7 8 5 6 4 2 3 1 8 7 6 2 4 5 3 1 8 7 6 2 4 5 3 1 Notes 1 Do not change sensitivity or dip switch settings with power applied 2 VR1 and VR2 are factory
160. ectrical components Have a quali ed li censed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury WARNING Mechanical Precautions The mechanical end stops cannot be moved or repositioned Doing so will adversely effect the operation of the valve The directional switch cannot be moved Maintain Factory Settings Wiring_85 On Off Control Line Volts 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input A B 2 9 8 10 12 18 Wiring_85 Floating Point AC Only GRB24 3 GRB24 3 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 86 Models GRX24 MFT T N4 w terminal block GRB24 MFT T N4H w heater Technical Data Control 2 to 10 VDC 4 to 20 mA default variable VDC oating point on off Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 8 W heater 29W holding 2 5 W Transformer sizing 11 VA class 2 power source heater 24 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance 100 k for 2 to 10 VDC 0 1 mA 500 for 4 to 20 mA 1000 f
161. en properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury WARNING Mechanical Precautions The mechanical end stops cannot be moved or repositioned Doing so will adversely effect the operation of the valve The directional switch cannot be moved Maintain Factory Settings 4 24 VAC Transformer a open a closed The indication of direction is valid for switch position 1 Blk 1 Common Red 2 Wht 3 ARB24 3 a Line Volts 1 0 W409 On Off Control xxx xxxx Floating Point AC Only DRCB24 3 DRCB24 3 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 70 Models DRX24 MFT T w terminal block DRX24 MFT T N4 w terminal block DRCX24 MFT T w terminal block DRCX24 MFT T N4 w terminal block DRCB24 MFT T N4H w heater Technical Data Control 2 to 10 VDC 4 to 20 mA default variable VDC oating point on off Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 6 5 W heater 27W holding 2 5 W Transformer sizing 9 5 VA class 2 power source heater 25 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 90 rotation Input impedance
162. es Valve Size Cv 90 Cv 60 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI 2 115 44 1 65 9 00 9 00 19 50 4 75 4 5 8 11 UNC AF 200 Spring Return F665HD 2 196 75 1 81 9 00 9 00 20 00 5 50 4 5 8 11 UNC 2 AF 200 F680HD 3 302 116 1 81 9 00 9 00 20 50 6 00 4 5 8 11 UNC 200 F6100HD 4 600 230 2 05 8 00 8 00 21 00 7 50 8 5 8 11 UNC 2 GK 200 Electronic Fail Safe F650HD 2 115 44 1 65 7 00 7 00 15 00 4 75 4 5 8 11UNC AMB X 200 Non Spring Return F665HD 2 196 75 1 81 7 00 7 00 15 50 5 50 4 5 8 11UNC 200 F680HD 3 302 116 1 81 8 00 8 00 16 00 6 00 4 5 8 11 UNC GMB X 200 F6100HD 4 600 230 2 05 8 00 8 00 21 00 7 50 8 5 8 11 UNC 2 GMB X 200 F6100HD 4 600 2 30 2 05 6 00 4 00 18 00 7 50 8 5 8 11 UNC DR DKR 200 F650HD 2 115 44 1 65 8 00 13 00 20 25 4 75 4 5 8 11 UNC SY2 200 F665HD 2 196 75 1 76 8 00 13 00 20 75 5 50 4 5 8 11 UNC 200 F680HD 3 302 116 1 78 8 00 13 00 21 00 6 00 4 5 8 11 UNC 200 F6100HD 4 600 230 2 05 8 00 13 00 21 75 7 50 8 5 8 11 UNC 200 F6125HD 5 1022 392 2 19 8 00 13 00 22 25 8 50 8 3 4 10 UNC 200 F6150HD 6 1579 605 2 19 8 00 13 00 22 75 9 50 8 3 4 10 UNC SY3 200 F6200HD 8 3136 1202 2 37 12 00 15 00 29 00 11 75 8 3 4 10 UNC SY4
163. forced Te on Seat 316 Stainless Disc Note For tee con guration please refer to page 5 Dimensions A B and C do not include ange gaskets 3 required per valve Application Notes 1 Valves are rated at 285 psi differential pressure in the closed position 100 F media temperature 2 Valves are furnished with lugs tapped for use between ANSI Class 125 150 anges conforming to ANSI B16 5 Standards 3 3 way assemblies are furnished assembled with Tee calibrated and tested ready for installation All 3 way assemblies require the customer to specify the 3 way con guration code prior to order entry to guarantee correct place ment of valves and actuator s on the assembly 4 Dimension D allows for actuator s removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data furnished upon request 6 Dual actuated valves have single actuators mounted on each valve shaft 7 Flange gaskets 3 required not provided with valve MUST be used between valve and ANSI ange 8 Flange bolts are not included with the valve These are furnished by others SHP series valves have a preferred flow direction PreferredFlowrate Dimensions 0 S D C A B D104 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 30 Bubble tight shut off to ANSI C
164. h switch A B Position indication 0 to 1 and reversible indicator Running time 150 sec Humidity 5 to 95 RH non condensing Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA 2 IP54 Housing material UL94 5VA ammability rating Agency listings cULus according to UL60730 1A 2 14 CAN CSA E60730 1 CSA C22 2 No 24 93 CE according to 89 336 EEC Noise level max 45 dB A Servicing maintenance free Quality standard ISO 9001 Note GR Actuators are on 2 way valves GM Actuators are on 3 way valves Dimensions with 2 Way Valve D B C A BHC Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC GM 2 GM F680HD 3 1 78 7 00 7 00 16 00 6 00 200 F6100HD 4 2 05 8 00 8 00 17 00 7 50 200 F6100HDU 4 2 05 8 00 8 00 17 00 7 50 50 F6125HDU 5 2 14 8 00 8 00 17 50 8 50 50 F6150HDU 6 2 19 8 00 8 00 22 50 9 50 50 F650 150SHP 2 1 75 9 00 9 00 19 50 4 75 285 F665 150SHP 2 1 88 9 00 9 00 20 00 5 50 285 F680 150SHP 3 1 92 9 00 9 00 20 50 6 00 285 F6100 150SHP 4 2 13 9 00 9 00 21 00 7 50 150 285 F650 300SHP 2 1 75 9 00 9 00 19 50 5 00 285 400 F665 300SHP 2 1 88 9 00 9 00 20 00 5 88 285 400 F680 300SHP 3 1 92 9 00 9 00 20 50 6 63 285 400 F6100 300SHP 4 2 13 9 00 9 00 21 00 7
165. ies Valves NON FAIL OPEN OPEN OPEN CLOSED OPEN X11 X12 X10 X13 X14 CONFIG CODE CLOSED NON FAIL OPEN CLOSED MASTER FAIL VALVE VALVE IS MASTER X15 CLOSED CLOSED NON FAIL NON FAIL CLOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER NON FAIL NON FAIL CLOSED CLOSED OPEN CODE CONFIG VALVE OPEN FAIL MASTER MOD 2VDC ON OFF OR CLOSED CLOSED CLOSED OPEN OPEN OPEN CLOSED CLOSED CLOSED OPEN OPEN OPEN ON OFF OR MOD 2VDC MASTER VALVE IS ON OFF OR MOD 2VDC MASTER VALVE IS X24 X25 X23 X22 X21 X20 X34 X35 X33 X32 X31 X30 X Specifies Bi Directional Flow Capability Notes 1 Slave Valve operates inversely of the Master Valve 2 The Master Valve is always located on the run 3 The Slave Valve may also have an actuator if required Direct Coupled 4 On Off actuator normal position is a function of field logic 5 Proportional actuator normal position is a function of the CCW CW 6 All 3 way assemblies are designed for 90 degree actuator rotation MASTER COMMON SLAVE MASTER SLAVE COMMON MASTER MASTER SLAVE SLAVE COMMON COMMON Flow in Std Weight Pipe Fluid Velocity in GPM Use with Resilient Seat BF Valves Size 2 FPS 4 FPS 6 FPS 8 FPS 10 FPS 12 FPS 14 FPS 16 FPS 2 19 39 59 78 98 117 137 157 2
166. inimum Valve Face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI B16 5 Flanges Completely assembled and tested ready for installation Tees comply with ASME ANSI B16 1 Class 125 Flanges Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN 3 way Spring Non Spring Electronic Fail Safe 102 56 2 F750 150SHP AF Series GM Series SY Series GK Series 146 80 2 F765 150SHP 228 125 3 F780 150SHP 451 248 4 F7100 150SHP 714 392 5 F7125 150SHP 1103 607 6 F7150 150SHP 2064 1135 8 F7200 150SHP 3517 1934 10 F7250 150SHP 4837 2660 12 F7300 150SHP 6857 3592 14 F7350 150SHP 9287 4865 16 F7400 150SHP 11500 3270 18 F7450 150SHP 14420 7590 20 F7500 150SHP 22050 11550 24 F7600 150SHP MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F750 150SHP 2 102 1 50 6 10 14 26 39 56 77
167. is prohibited Terminals 4 and 6 need to be wired separately Control signal Feedback G 34 36 34 36 W547_11 Wiring for Control Valves Proportional 24V 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 54 Each actuator should be powered by a single isolated control transformer wiring to a common is prohibited Actuator SY2 5 24MFT SY2 12 120MFT SY2 12 230MFT Indicates an action or condition that may cause irreversible damage to the actuator s or associated equipment CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices this manual Read these carefully Hazard Identification 33 INSTALLATION NOTES Use of feedback is optional APPLICATION NOTES 34 36 Ground shielded wire at control panel chassis Tape back ground at actuator NOTES SY2 5 24MFT NOTES SY2 12 120MFT 230MFT Caution SY2 5 24MFT SY2 12 120MFT 230MFT A B C E F LS4 LS3 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Control Signal Not Used Internal Use Only Internal Use Only Internal Use Only Internal U
168. is product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury GM GR Actuators Multi Function Technology 7 Blk 1 Common Red 2 Hot Wht 3 Y1 Input 2 to 10V Org 5 U Output 2 to 10V 4 to 20 mA or 2 to 10 VDC Control Signal Line Volts 24 VAC Transformer 500 1 4 watt 3 5 CCW CW W545_No_2 VDC 4 20 mA Blk 1 Common Red 2 Hot Wht 3 Y Input Org 5 U Output Line Volts 24 VAC DC Transformer a Position Feedback VDC 3 W545_No_2 Two Position CCW CW A B 5 CCW CW A B 5 Direction of rotation switch Line Volts 2 to 10 VDC Feedback Signal 24 VAC Transformer Blk 1 Common Red 2 Hot Wht 3 Y1 Input Org 5 U Output 2 to 10V Pnk 4 Y2 Input 8 3 A B 9 10 11 W545_No_2 Floating Point Blk 1 Common Red 2 Hot Wht 3 Y Input Org 5 U Output Line Volts 24 VAC Transformer AC only 8 Position Feedback VDC W545_No_2 PWM Blk 1 Common Red 2 Hot Wht 3 Y Input 2 to 10 V Org 5 U Output 2 to 10 V CCW CW Master
169. isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Jobsite Note Valves should be stored in a weather protected area prior to construction Valve Size Cv 30 40 50 60 70 90 F650VIC 2 115 7 14 23 36 60 115 F665VIC 2 1 2 260 16 30 50 80 140 260 F680VIC 3 440 26 50 90 140 230 440 F6100VIC 4 820 50 100 160 250 430 820 F6125VIC 5 1200 70 140 240 370 620 1200 F6150VIC 6 1800 110 220 360 560 940 1800 F6200VIC 8 3400 200 410 670 1050 1770 3400 F6250VIC 10 5800 350 700 1150 1800 3020 5800 F6300VIC 12 9000 540 1080 1780 2790 4680 9000 2 way Suitable Actuators Valve Nominal Size Type Spring Return Non Spring Return Electronic Fail Safe Cv 90 Cv 60 IN DN mm 2 way 115 36 2 50 F650VIC AF Series AM SY Series 260 80 2 65 F665VIC GM Series GK Series 440 140 3 80 F680VIC 820 250 4 100 F6100VIC 1200 370 5 125 F6125VIC 1800 560 6 150 F6150VIC 3400 1050 8 200 F6200VIC 5800 1800 10 250 F6250VIC 9000 2790 12 300 F6300VIC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA
170. ith protected switch Position indication handle Manual override external push button Running time 150 seconds default variable 90 to 350 secs Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA 2 IP54 Housing material UL94 5VA Agency listings cULus according to UL60730 1A 2 14 CAN CSA E60730 1 CSA C22 2 No 24 93 CE according to 89 336 EEC Noise level lt 45dB A Quality standard ISO 9001 Rated impulse voltage 4kV Control pollution degree 3 Type of action 1 AM AR Series Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC Dimensions Inches Valve Size A B C D Max BHC Non Spring Return psi F650HD U 2 1 65 3 35 7 00 14 50 4 75 F665HD U 2 1 76 3 46 7 00 15 00 5 50 F680HDU 3 1 78 3 48 7 00 15 50 6 00 F650VIC 2 3 21 7 00 7 00 14 50 F665VIC 2 3 77 7 00 7 00 14 50 Dimensions with 3 Way Valve Dimensions Inches Non Fail Safe psi Valve Size A B C D Max BHC HD HDU F750HD 2 4 50 6 15 6 15 15 50 4 75 200 F765HDU 2 5 00 6 76 6 76 16 00 5 50 200 50 F750VIC 2 3 21 6 00 6 00 15 00 50 AR_LineRevised Single_Butter y 10 0 D A B C O50904 02 12 Subject to change Belimo Aircontrols USA
171. l Input Output Mains Power 220VAC A C Line Voltage RD X SA 161 24 BR BK WH RD X BK RD BK 1 U5 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 As outlined below Max Load 150VA K1 K2 L2 neutral L1 hot GND AC DC AC DC NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for multiple proportional SY series 220 VAC actuators Do NOT exceed the Max Loads as stated above when connecting multiple actuators Actuators connected in this manner operate in parallel from the common automation control signal and will fail safe position together Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuators as shown Observe wire size rules for longer wire runs K1 and K2 must be supplied 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 108 O50904 02 12 Subject to change Belimo Aircontrols USA Inc BACK UPS CS 350VA PART NUMBER BK350 Availability North America Latin America Product Overview Description APC Back UPS 350VA 210W Input 120V Output 120V General Features Addl Surge Protected Outlets Audible Alarms Cord Management Intelligent Battery Management Internet FAX modem DSL protection Overload Indicator
172. l Torque Output Runtime secs Draw amps 2 Position Model Modulating Model Runtime at 50 Capacity minutes Capacity Used at Full Runtime Replacement Battery SY1 110 P 310 12 0 5 NSV SY 01 NSV SY 02 47 0 4 RBC2 SY2 110 MFT 801 15 1 0 NSV SY 01 NSV SY 02 35 0 7 RBC2 SY3 110 MFT 1335 22 1 0 NSV SY 01 NSV SY 02 35 1 0 RBC2 SY4 110 MFT 3560 16 1 3 NSV SY 01 NSV SY 02 19 1 4 RBC2 SY5 110 MFT 4450 22 1 5 NSV SY 01 NSV SY 02 17 2 2 RBC2 SY6 110 MFT 5785 28 1 85 NSV SY 01 NSV SY 02 17 2 7 RBC2 SY7 110 MFT 8900 46 3 2 NSV SY 03 NSV SY 04 5 15 3 RBC2 SY8 110 MFT 13350 46 4 0 NSV SY 05 NSV SY 06 15 5 1 RBC32 SY9 110 MFT 17800 58 3 2 NSV SY 05 NSV SY 06 24 4 0 RBC32 SY10 110 MFT 22250 58 4 0 NSV SY 05 NSV SY 06 15 6 4 RBC32 SY11 110 MFT 26700 58 3 0 NSV SY 05 NSV SY 06 25 3 9 RBC32 SY12 110 MFT 31150 58 4 0 NSV SY 05 NSV SY 06 15 6 4 RBC32 SY1 24 P 310 15 1 8 NSV SY 11 NSV SY 12 60 0 4 RBC2 SY2 24 MFT 801 15 3 0 NSV SY 11 NSV SY 12 40 0 6 RBC2 SY3 24 MFT 1335 22 3 0 NSV SY 11 NSV SY 12 40 0 9 RBC2 SY4 24 MFT 3560 16 6 0 NSV SY 11 NSV SY 12 20 1 3 RBC2 SY5 24 MFT 4450 22 6 5 NSV SY 11 NSV SY 12 19 1 9 RBC2 SY1 220 P 310 12 0 3 NSV SY 21 NSV SY 22 42 0 5 RBC2 SY2 220 MFT 801 15 0 5 NSV SY 21 NSV SY 22 36 0 7 RBC2
173. lass 300 Standards Long stem design allows for 2 insulation minimum Valve Face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI B16 5 Flanges Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Valve Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN ANSI 300 2 way Spring Non Spring Electronic Fail Safe 100 52 2 F650 300SHP AF Series GM Series SY Series GK Series 143 75 2 F665 300SHP 223 117 3 F680 300SHP 435 228 4 F6100 300SHP 688 361 5 F6125 300SHP 1041 546 6 F6150 300SHP 1911 1001 8 F6200 300SHP 3194 1673 10 F6250 300SHP 4428 2319 12 F6300 300SHP 5702 2986 14 F6350 300SHP 8243 3988 16 F6400 300SHP 9712 5088 18 F6450 300SHP 10658 5775 20 F6500 300SHP 16205 8855 24 F6600 300SHP MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F650 300SHP 2 100 1 40 6 0
174. less steel RPTFE 17 4 PH stainless PTFE glass backed PTFE Media temperature range 20 F to 400 F 30 C to 204 C Body pressure rating ANSI Class 300 Close off pressure 740 psi Rangeability 100 1 for 30 deg to 70 deg range Maximum velocity 32 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 33 Maximum Dimensions Inches Valve Size Cv 90 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI F750 300SHP 2 100 5 00 6 75 6 75 15 50 5 00 8 5 8 11 UNC 2 GK 285 Electronic Fail Safe F765 300SHP 2 143 5 50 7 38 7 38 16 00 5 88 8 3 4 10 UNC 285 F780 300SHP 3 223 6 00 7 92 7 92 16 25 6 63 8 3 4 10 UNC 285 F7100 300SHP 4 435 7 00 9 13 9 13 18 00 7 88 8 3 4 10 UNC 150 F750 300SHP 2 100 5 00 6 75 6 75 15 50 5 00 8 5 8 11 UNC 2 GM 285 Non Spring Return F765 300SHP 2 143 5 50 7 38 7 38 16 00 5 88 8 3 4 10 UNC 285 F780 300SHP 3 223 6 00 7 92 7 92 16 25 6 63 8 3 4 10 UNC 285 F7100 300SHP 4 435 7 00 9 13 9 13 18 00 7 88 8 3 4 10 UNC 150 F750 300SHP 2 100 5 00 6 75 6 75 22 25 4 75 8 5 8 11 UNC SY2 400 SY3 600 F765 300SHP 2 143 5 50 7 38 7 38 22 75 5 50 8 3 4 10 UNC SY2 400 SY3 600 F780 300SHP 3 223 6 00
175. limo Technical Support for applications involving steam high velocity requirements etc Installation Recommendations SHP Series Butter y Valves Storage of Butterfly Valve Assemblies Assemblies must be stored indoors protected from the elements Materials received on job sites that have long installation lead times should receive extra protection from construction damage Valve faces must be protected from abrasion cutting and nicking as this will damage the face and may cause flange area leaks Electric actuators cannot be stored in wet damp or caustic areas Do not store construction material on top of valve assemblies Installation Practices SHP series butterfly valves are designed to be installed between ANSI 125 150 flat faced or raised face slip on weld neck flanges Valve should be installed a minimum of 6 pipe diameters from upstream or downstream elbows strainers pumps etc For chilled water condenser water or hot water applications the valve should be installed with the stem in a vertical orientation with the actuator mounted above the valve For applications in which there is a possibility of sediment in the flow the valve should be installed with the stem in a horizontal position and the bottom of the disc should close FROM the downstream side rather than from the upstream side Flange gaskets must be used on SHP series BF valves Make sure
176. n the system the actuators are then trying to turn in both directions at once The EMF voltage is always less than the supply voltage due to the resistance of the windings so while the actuator still turns in the commanded direction the drag from the other reduces the torque output and causes overheating CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification 33 33 INSTALLATION NOTES 24V AC DC Transformer Line Voltage G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback Feedback B G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback SY1 24P 24V AC DC Transformer Line Voltage Feedback A Control Signal Actuator B Actuator A Use of feedback is optional APPLICATION NOTES Recommended twisted shielded pair for control wiring Ground shielded wire at control panel chassis Tape back ground at actuator SY1 24P A B C E F Contact Rating 5A 125 V
177. nce between Actuator and Supply feet 18 92 55 55 16 144 87 87 43 40 14 233 140 140 70 65 12 357 214 214 107 99 10 606 364 364 182 168 8 905 543 543 271 250 24 VAC SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12 Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps wire gauge 0 5 1 1 1 3 1 5 1 8 3 2 4 3 2 4 3 4 MAX Distance between Actuator and Supply feet 18 1515 758 758 583 505 421 237 189 237 189 253 189 16 2381 1190 1190 916 794 661 372 298 372 298 397 298 14 3846 1923 1923 1479 1282 1068 601 481 601 481 641 481 12 5882 2941 2941 2262 1961 1634 919 735 919 735 980 735 10 10000 5000 5000 3846 3333 2778 1563 1250 1563 1250 1667 1250 8 14925 7463 7463 5741 4975 4146 2332 1866 2332 1866 2488 1866 110 VAC SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12 Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps wire gauge 0 3 0 5 0 5 0 6 0 7 0 8 1 6 2 1 6 2 1 6 2 2 MAX Distance between Actuator and Supply feet 18 5051 3030 3030 2525 2165 1894 947 758 947 758 947 689 16 7937 4762 4762 3968 3401 2976 1488 1190 1488 1190 1488 1082 14 12821 7692 7692 6410 5495 4808 2404 1923 2404 1923 2404 1748 12 19608 11765 11765 9804 8403 7353 3676 2941 3676 2941 3676 2674 10 33333 20
178. nents G During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components Have a quali ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks Failure to follow all electrical safety precautions when exposed to live electrical compo nents could result in death or serious injury AFBUP AFBUP S AFXUP AFBUP S W066_AFB X UP On Off wiring Wht Blk AFBUP S AFXUP S W067_AFB X UP S Auxiliary Switches for S Models Dimensions with 3 Way Valve 10 10 D A B C Dimensions Inches Fail Safe psi Valve Size A B C D Max BHC AF 2 AF F750HD 2 4 50 6 15 6 15 15 50 4 75 200 F750HDU 2 4 50 6 15 6 15 15 50 4 75 50 F765HD 2 5 00 6 76 6 76 16 00 5 50 200 F765HDU 2 5 00 6 76 6 76 16 00 5 50 50 F780HDU 3 5 50 7 28 7 28 16 25 6 00 50 F750VIC 2 4 50 6 85 6 85 15 00 50 F750VIC 2 4 50 6 85 6 85 15 00 200 F765VIC 2 5 00 7 46 7 46 15 50 50 AFBUP S X1 AFXUP S X AFRBUP S AFRXUP S Actuators On Off O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 62 Dimensions with 2 Way Valve A B C D BHC BF2WUDIM_A BF2WUDIM AF Actuators Multi Fun
179. ng mains power is connected to G N amp H terminals A control switch or dry contacts are connected between terminal A8 and M2 or M3 to control the positioning of the actuator under power Terminals AG A1 A5 A6 amp A7 are connected to the SY actuator as shown Observe wire size rules for longer wire runs 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 97 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Wiring diagram for multiple on off SY series 110 VAC actuators NSV SY Battery Back Up System Wiring Diagrams K1 COIL MUST MATCH SUPPLY VOLTAGE IN THIS SCENARIO ACTUATOR 1 WORKS OPPOSITE ACTUATOR 2 IN THIS EXAMPLE K1 IS A 4PDT RELAY NOTES Do NOT exceed total VA capacity AUTOMATION SYSTEM OR SWITCH Max Load 500VA NSV SY 05 Max Load 300VA NSV SY 03 Max Load 150VA NSV SY 01 of NSV SY backup system NOTE FIELD WIRING A1 AG A7 A5 A6 OPEN CLOSE G N K1 B K1 CLOSE OPEN A8 H 110VAC M3 M2 K1 A AUX SW TERMINALS CONTROL SIGNALS AND POWER SY 1 12 110 D Opened to Closed to 5A 250VAC MAX D 5A 250VAC MAX ACTUATOR 2 AUX SW TERMINALS Opened to Closed to OBSERVE POLARITY OF 5 Close to Open to Hot to G 3 1 4 7 4 3 7 6 B A C 5 Open to Close to Hot to 3 G 3 4 3 6 7 3 4 7 B A C C
180. nge bolting sequence Fig 8 pg 85 When installing in Victaulic piping systems use Victaulic 41 series flange nipples Installation using Welded Flanges Mount flanges on both sides of valve body and install bolts to properly align valve body and both flanges Install the valve with the disc in the Almost Closed position Fig 1 Do not use any flange gaskets Fig 1a Make sure the valve liner and flange internal diameters are in alignment Fig 2 Take valve body flange pair assembly and align with piping ends TACK weld the flanges to the piping in several places Fig 3a Do NOT seam weld at this time Remove the lug bolts and carefully remove the valve body from the flanges Seam weld the entire flange piping connection for both flanges Fig 3b Let the piping components cool completely before re inserting the valve body Fig 4 WARNING Seam welding with the valve body installed between the flanges can damage the liner due to heat migration through the flange to the valve body Installation Recommendations F6 HD U F7 HD U Series Butter y Valves HD U Series Butter y Valves Max Torque for Bolts Valve Size Bolt Size Max Torque ft lbs 2 4 5 8 70 5 8 3 4 120 10 12 7 8 200 14 16 1 240 18 20 1 1 8 380 24 30 1 1 4 520 32 48 1 1 2 80
181. nic throughout 0 to 95 rotation Control On Off Torque 180 in lb 20 Nm minimum Direction of rotation spring reversible with CW CCW mounting Mechanical angle of rotation 95 adjustable with mechanical end stop 35 to 95 Running time motor lt 75 sec spring 20 sec 4 F to 122 F 20 C to 50 C lt 60 sec 22 F 30 C Position indication visual indicator 0 to 95 0 is full spring return position Manual override 5 mm hex crank Allen supplied Humidity max 95 RH non condensing Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing Nema 2 IP54 Enclosure Type2 Housing material Zinc coated metal and plastic casing Agency listings cULus acc to UL60730 1A 2 14 CAN CSA E60730 1 02 CE acc to 2004 108 EC amp 2006 95 EC Noise level lt 50dB A motor 75 seconds 62dB A spring return Servicing maintenance free Quality standard ISO 9001 Weight 4 6 lbs 2 1 kg 4 9 lbs 2 25 kg with switches Rated Impulse Voltage 4kV Type of action 1 AA 1 AA B for S version Control Pollution Degree 3 AFBUP S X1 AFXUP S X1 AFRBUP S 5 AFRXUP S Auxiliary switches 2 x SPDT 3A 0 5A 250 VAC UL Approved one set at 10 one adjustable 10 to 90 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA
182. ntrol applications The large Cv values provide for an economical control valve solution for larger ow applications Designed for use in Victaulic piping systems when mated to Victaulic 41 series ange nipples Jobsite Note Valves should be stored in a weather protected area prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F7 HDU Butter y Valves Nominal Size Type Suitable Actuators Cv 90 Cv 60 IN DN mm 3 way Spring Non Spring Electronic Fail Safe 115 44 2 50 F750HDU AF Series AM SY Series 196 75 2 65 F765HDU 302 116 3 80 F780HDU GM Series 600 230 4 100 F7100HDU GK Series 1022 392 5 125 F7125HDU 1579 605 6 150 F7150HDU 3136 1202 8 200 F7200HDU 5340 2047 10 250 F7250HDU 8250 3062 12 300 F7300HDU MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F750HDU 2 115 06 3 7 15 27 44 70 105 115 F765HDU 2 196 10 6 12 25 45 75 119 178 196 F780HDU 3 302 20 9 18 39 70 116 183 275 302 F7100HDU 4 600 30 17 36 78 139 230 364 546 600 F7125HDU 5 1022 50 29 61 133 237 392 620 930 1022 F7150HDU 6 1579 80 45 95 205 366 605 958 1437 1579 F7200HDU 8 3136 2 89 188 408 727 1202 1903 2854 3136 F7250HDU 10
183. o 250 F 30 C to 120 C Body pressure rating ASME ANSI Class 125 150 Close off pressure 200 psi 2 12 150 psi 14 30 Rangeability 10 1 for 30 to 70 range Maximum velocity 12 FPS Leakage bubble tight O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 35 Maximum Dimensions Inches Valve Size Cv 90 Cv 60 A B C D E BHC No of Holes Lug Bolt Operator Close Off PSI Weight lbs kg 2 115 44 1 69 n a 10 44 7 68 n a 4 75 4 5 8 11 UNC HND01 200 11 2 5 1 F665HD 2 196 75 1 81 n a 10 44 8 27 n a 5 50 4 5 8 11 UNC 200 13 2 6 0 F680HD 3 302 116 1 81 n a 10 44 8 54 n a 6 00 4 5 8 11 UNC 200 13 2 6 1 F6100HD 4 600 230 2 06 n a 11 81 9 45 n a 7 50 8 5 8 11 UNC HND02 200 19 2 8 7 F6125HD 5 1022 392 2 19 n a 11 81 9 76 n a 8 50 8 3 4 10 UNC 200 24 2 11 0 F6150HD 6 1579 605 2 19 n a 11 81 10 2 n a 9 50 8 3 4 10 UNC 200 29 2 13 2 F6200HD 8 3136 1202 2 38 n a 14 06 11 93 n a 11 75 8 3 4 10 UNC HND03 200 43 4 19 7 Valve Size Cv 90 Cv 60 A B C D E BHC No of Holes Lug Bolt Operator Close Off PSI Weight lbs kg 2 115 44 1 69 4 70 2 10 10 71 6 45 4 75 4 5 8 11 UNC GW01 200 19 8 6 F665HD 2 196 75 1 81 4 70 2 10
184. o meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications The large Cv values provide for an economical control valve solution for larger ow applications Jobsite Note Valves should be stored in a weather protected area prior to construction Valve Size Cv 30 40 50 60 70 90 F750VIC 2 115 7 14 23 36 60 115 F765VIC 2 260 16 30 50 80 140 260 F780VIC 3 440 26 50 90 140 230 440 F7100VIC 4 820 50 100 160 250 430 820 F7125VIC 5 1200 70 140 240 370 620 1200 F7150VIC 6 1800 110 220 360 560 940 1800 F7200VIC 8 3400 200 410 670 1050 1770 3400 F7250VIC 10 5800 350 700 1150 1800 3020 5800 F7300VIC 12 9000 540 1080 1780 2790 4680 9000 3 way Suitable Actuators Valve Nominal Size Type Spring Return Non Spring Return Electronic Fail Safe Cv 90 Cv 60 IN DN mm 2 way 115 36 2 50 F750VIC AF Series AM GM Series SY Series GK Series 260 80 2 65 F765VIC 440 140 3 80 F780VIC 820 250 4 100 F7100VIC 1200 370 5 125 F7125VIC 1800 560 6 150 F7150VIC 3400 1050 8 200 F7200VIC 5800 1800 10 250 F7250VIC 9000 2790
185. ons Gear Wheel E D B C A B H C Belimovalve_handle_assyModel Dimension A is compressed add 0 125 for relaxed state Application Notes 1 Valves are rated at 200 psi differential pressure in the closed position SY 150 psi 14 2 Valves are furnished with lugs tapped for use with ANSI Class 125 150 anges Installation anges and hardware are not included 3 2 way assemblies are furnished assembled and tested ready for installation F6 Series 2 Way HD Butter y Valve Resilient Seat 304 Stainless Disc with Manual Handle or Gear Wheel Operator O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 36 Bubble tight shut off to ANSI Class 150 Standards Long stem design allows for 2 insulation minimum Valve face to face dimensions comply with API 609 amp MSS SP 68 Designed to be installed between ASME ANSI B16 5 Flanges Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and Commercial applications requiring positive shut off for liquids at higher pressures and temperatures Typical applications include chiller isolation cooling tower isolation change over systems large air handler coil control bypass and process control applications Jobsite Note Valves should be stored in a weather protected area
186. or oating point and on off control Angle of rotation 90 adjustable with mechanical stop electronically variable Position indication visual pointer Manual override internal push button UL Type 4 Running time 150 seconds default variable 75 to 290 seconds Humidity 5 to 100 RH UL Type 4 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 GRX B 24 MFT T N4 H NEMA 4 Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A BHC GR_NEMA_4_LineDrawing Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D FLG F650HD HDU 2 50 1 65 41 9 10 49 266 3 62 92 18 94 481 F05 F665HD HDU 2 5 65 1 76 44 7 10 49 266 3 62 92 19 49 495 F05 F680HD HDU 3 80 1 78 45 2 10 49 266 3 62 92 19 73 501 F05 F6100HDU 4 100 2 05 52 1 10 49 266 3 62 92 20 47 520 F07 F6125HDU 5 125 2 14 54 4 10 49 266 3 62 92 20 99 533 F07 O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 87 Wiring
187. or s or associated equipment Equipment damage Power consumption and input impedance must be observed CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Warnings and Cautions appear at appropriate sections throughout this manual Read these carefully Hazard Identification G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback Feedback B G Ground 4 Power Supply Com 5 Power Supply Hot 6 Control Signal 7 Control Signal 8 Internal Use Only 9 Internal Use Only 10 Internal Use Only 11 Feedback 12 Feedback Feedback A Control Signal Actuator B Actuator A 120 or 230 VAC N L1 H L2 SY1 110P 220P A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication SY1 110P 220P A B C E F Contact Rating 5A 125 VAC Max 3A 250 VAC Max A B Open Indication LS4 LS3 A E Closed Indication Actuators SY1 110P SY1 220P NOTES SY1 110P 220P Caution Power supply voltage power applied Use of feedback is optional APPLICATION NOTES Recommended twisted shielded pair for control wiring Groun
188. ould be mounted on the valve prior to installation to facilitate proper alignment of the disc in the valve seat 4 Check the valve identi cation tag for materials and operating pressure to be sure they are correct for the application Installation Recommendations F6 HD U F7 HD U Series Butter y Valves FLANGE BOLTING RECOMMENDATIONS Flange Detail for ANSI B16 5 Pipe Flanges FLANGES DRILLING BOLTING Nominal Pipe Size A Flange Diameter B Flange Thickness C Diameter of Bolt Circle D Diameter of Bolt Holes Number of Bolts Diameter of Bolts 2 6 3 4 4 3 4 3 4 4 5 8 2 1 2 7 7 8 5 1 2 3 4 4 5 8 3 7 1 2 15 16 6 3 4 4 5 8 4 9 15 16 7 1 2 3 4 8 5 8 5 10 15 16 8 1 2 7 8 8 3 4 6 11 1 9 1 2 7 8 8 3 4 8 13 1 2 1 1 8 11 3 4 7 8 8 3 4 10 16 1 3 16 14 1 4 1 12 7 8 12 19 1 1 4 17 1 12 7 8 14 21 1 3 8 18 3 4 1 1 8 12 1 16 23 1 2 1 7 16 21 1 4 1 1 8 16 1 18 25 1 5 8 22 3 4 1 1 4 16 1 1 8 20 27 1 2 1 11 16 25 1 1 4 20 1 1 8 24 32 1 7 8 29 1 2 1 3 8 20 1 1 4 WARNING Personal injury or property damage may result if the valve is installed where service conditions could exceed the val
189. ounted solutions O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 76 AM AR Series Actuators On Off Floating Point Models AMB24 3 X1 ARB24 3 X1 ARB24 3 5 Technical Data Power supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 2 0 W holding 0 2 W Transformer sizing 5 5 VA class 2 power source Electrical connection 3 ft 18 GA plenum rated cable conduit connector Overload protection electronic throughout 0 to 95 rotation Control on off oating point Input impedance 600 Angle of rotation 95 adjustable with mechanical stop Direction of rotation reversible with protected switch Position indication handle Manual override external push button Running time 95 seconds Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing NEMA 2 IP54 Housing material UL94 5VA Agency listings cULus according to UL 60730 1A 2 14 CAN CSA E60730 1 CSA C22 2 No 24 93 CE according to 89 336 EEC and 2006 95 EC for line voltage and or S versions Noise level lt 45dB A Quality standard ISO 9001 Note AR Actuators are on 2 way valves AM Actuators are on 3 way valves Dimensions with 2 Way Valve AR_LineRevised Dimensions Inches Non Fail Safe psi
190. ower supply 24 VAC 20 50 60 Hz 24 VDC 10 Power consumption running 8 W heater 29W holding 2 5 W Transformer sizing 11 VA class 2 power source heater 26 VA Electrical connection screw terminal for 22 to 12 AWG wire Overload protection electronic throughout 0 to 95 rotation Input impedance 100 k for 2 to 10 VDC 0 1 mA 500 for 4 to 20 mA 1000 for oating point and on off control Angle of rotation 95 adjustable with mechanical stop electronically variable Direction of rotation reversible with Position indication visual pointer Manual override internal push button UL Type 4 Running time 150 seconds default variable 75 to 290 seconds Humidity 5 to 100 RH UL Type 4 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C Housing type UL Type 4 NEMA 4 IP66 Housing material Polycarbonate Agency listings cULus according to UL 60730 1A UL 60730 2 14 and CAN CSA E60730 1 Certi ed to IEC EN 60730 1 and IEC EN 60730 2 14 EMC CE according to 2004 108 EC Quality standard ISO 9001 GMX B 24 MFT T N4 H NEMA 4 Actuators Multi Function Technology Dimensions with 2 Way Valve D B C A ZM0825 Valve Nominal Size Dimensions Inches mm Valve Body Inches DN mm A B C D F650 150SHP 2 50 1 75 44 5 3 62 92 10 49 266 17 32 440 F665 150SHP 2 5 65 1 88 47 8 3 62 92 10 49
191. prior to construction Complete installation recommendations can be found in Belimo s Installation and Maintenance Instructions for F6 SHP 150 Butter y Valves Valve Nominal Size Type Manual Operators Cv 90 Cv 60 IN DN mm ANSI 150 2 way 102 56 2 50 F650 150SHP Handle Gear Wheel OP 146 80 2 65 F665 150SHP 228 125 3 80 F680 150SHP 451 248 4 100 F6100 150SHP 714 392 5 125 F6125 150SHP 1103 607 6 150 F6150 150SHP 2064 1135 8 200 F6200 150SHP 3517 1934 10 250 F6250 150SHP 4837 2660 12 300 F6300 150SHP 6857 3592 14 350 F6350 150SHP 9287 4865 16 400 F6400 150SHP 11500 3270 18 450 F6450 150SHP 14420 7590 20 500 F6500 150SHP 22050 11550 24 600 F6600 150SHP 34388 18012 30 750 F6750 150SHP Valve Size Cv 10 20 30 40 50 60 70 80 90 F650 150SHP 2 102 1 5 6 1 14 26 39 56 77 99 102 F665 150SHP 2 146 2 2 8 8 20 37 55 80 110 142 146 F680 150SHP 3 228 3 4 14 32 57 87 125 171 221 228 F6100 150SHP 4 451 7 27 63 114 171 248 338 437 451 F6125 150SHP 5 714 11 43 100 180 271 393 536 693 714 F6150 150SHP 6 1103 17 66 154 278 419 607 827 1070 1103 F6200 150SHP 8 2064 31 124 289 520 784 1135 1548 2002 2064 F6250 150SHP 10 3517 53 211 492 886 1336 1934 2638
192. r 120VAC A C Line Voltage OUT IN BK 2 1 DISCONNECT THE WIRE FROM TERMINAL 3 AND A CONNECT TO TERMINAL A6 ON THE NSV A5 NSV SY Battery Back Up System Wiring Diagrams Wiring diagram for a single proportional SY series 24 VAC actuator Building mains power is connected to G N amp H terminals The control signal from the automation system is wired directly to the SY actuator Terminals AG A2 A5 A6 M2 amp M3 are connected to the SY actuator as shown Observe wire size rules for longer wire runs The 24vac transformer required to run the SYxxx 24 actuator is built in to the NSV cabinet 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 103 O50904 02 12 Subject to change Belimo Aircontrols USA Inc K1 A K1 B K2 B K2 A NSV SY 12 G N H A2 A6 M2 M3 AG RD SA 161 24 BR BK WH RD OUT IN BK RD BK 1 U5 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 AC DC Analog Signal Input Output Mains Power 24VAC A C Line Voltage RD SA 161 24 BR BK WH RD BK RD BK 1 U5 2 C1 C2 Y 3 2 1 B A 9 10 8 2 3 4 5 6 7 1 AC DC As outlined below Max Load 150VA K1 K2 L2 neutral L1 hot GND X X X X DISCONNECT THE WIRE FROM TERMINAL 3 AND A CONNECT TO TERMINAL A6 ON THE NSV DISCONNECT THE WIRE
193. r actuator removal without the need to remove the valve from the pipe 5 Weather shields are available dimensional data upon request 6 Dual actuated valves have single actuators mounted on each valve shaft 7 Bolts supplied are for shipping purposes only Upon installation replace with an appropriate SAE grade 5 or better hardware 8 Belimo SY Series actuators are NEMA 4X rated Dimensions 0 S HS DWGP15 D A B C O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 11 F6 Series 2 Way HD Butter y Valve Resilient Seat 304 Stainless Disc Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed equal percentage Controllable ow range 82 Sizes 2 to 30 Type of end tting for use with ANSI 125 150 anges Materials Body Body nish Disc Seat Shaft O ring Bushings ductile iron ASTM A536 epoxy powder coated 304 stainless steel EPDM standard 416 stainless steel EPDM RPTFE Media temperature range 22 F to 250 F 30 C to 120 C Body pressure rating ASME ANSI Class 125 150 Close off pressure 200 psi 2 12 150 psi 14 30 Rangeability 10 1 for 30 to 70 range Maximum velocity 12 FPS Leakage bubble tight 200 psi 2 to 12 and 150 psi 14 30 bubble tight shut off Long stem design allows for 2
194. re is no shaft binding or seat damage before reinstalling the valve in the pipeline 20 Reinstall the actuator mounting hardware and actuator Remote Actuator Male Drive Adjust the stops in the actuator to position the face of the disc parallel with the face of the valve body in the closed position and perpendicular to the face of the valve body in the open position Caution The overtravel stop in the valve body is not to be used as an actuator stop Disc Shaft and Bearing Replacement Parts List Through Shaft Design Item Number Description 1 Body 2 Seat Retainer 3 Disc 4 Shaft 5 Seat 6 Seat O Ring 7 Bearing 8 Packing 9 Gland 10 Gland Follower 11 Disc Thrust Spacer 2 to 5 12 Set Screws 13 Wedge Pins 14 Gland Flange Stud 15 Gland Flange Nut 16 Lock Washer 17 Wedge Ring O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 42 Features Bene ts Butter y Valves Domed Position Indicator Domed Position Indicator Cast Aluminum Cover d Powder Coate Powder Coated Four Cover Screws for Easy Access Easy Access Thermally Protected Drive Motor Drive Motor Simple Single Handed el SY2 12 Override Whe Override Wheel SY2 12 Hardened Steel Gear Sets Gear Sets Bearing Seals Bearing Seals ISO 5211Mounting System ISO 5211Mounting Sy
195. ries actuators are NEMA 4X rated and include 2 auxiliary switches and a heater O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 5 Industrial Actuation Average Assembly Weights ACTUATOR NON SPRING RETURN Size Valve Max GPM COP SY1 SY2 SY3 SY4 UNDERCUT MODELS 2 WAY 2 F650HDU 118 50 14 lbs 2 5 F665HDU 184 50 14 lbs 3 F680HDU 264 50 15 lbs 4 F6100HDU 470 50 46 lbs 5 F6125HDU 734 50 50 lbs 6 F6150HDU 1058 50 54 lbs 8 F6200HDU 1880 50 62 lbs 10 F6250HDU 2938 50 79 lbs 12 F6300HDU 4230 50 98 lbs 3 WAY 2 F750HDU 118 50 46 lbs 2 5 F765HDU 184 50 55 lbs 3 F780HDU 264 50 84 lbs 4 F7100HDU 470 50 134 lbs 5 F7125HDU 734 50 163 lbs 6 F7150HDU 1058 50 197 lbs 8 F7200HDU 1880 50 273 lbs 10 F7250HDU 2938 50 452 lbs 12 F7300HDU 4230 50 603 lbs ACTUATOR NON SPRING RETURN Size Valve Max GPM COP SY2 SY3 SY4 SY6 SY7 SY8 SY10 SY12 FULL RATED MODELS 2 WAY 2 F650HD 118 200 36 lbs 2 5 F665HD 184 200 36 lbs 3 F680HD 264 200 36 lbs 4 F6100HD 470 200 46 lbs 5 F6125HD 734 200 50 lbs 6 F6150HD 1058 200 54 lbs 8 F6200HD 1880 200 86 lbs 10 F6250HD
196. rn 2 Pos Set Up Required Field Logic Determines Normal Position Non Spring Return 2 Pos Specify Flow Pattern 10 35 No Set Up Required Field Logic Determines Normal Position Modulating NC Normally Closed 1 VDC 2 VDC 4mA Closed Modulating Master Actuated Valve NC Normally Closed 1 VDC 2 VDC 4mA Closed NO Normally Open 1 VDC 2 VDC 4mA Open Master Actuated Valve NO Normally Open 1 VDC 2 VDC 4mA Open Spring Return NO FO Normally Open Fail Open Field Logic Determines Normal Position Spring Fails Valve OPEN Spring Return Modulating 2 Pos Specify Flow Pattern 10 35 NO FO Normally Open Fail Open Field Logic Determines Normal Position Spring Fails Master Valve OPEN NC FC Normally Closed Fail Closed Field Logic Determines Normal Position Spring Fails Valve CLOSED NC FC Normally Closed Fail Closed Field Logic Determines Normal Position Spring Fails Master Valve CLOSED NO FO Normally Open Fail Open 1 VDC 2 VDC 4mA Open Spring Fails Valve OPEN NO FO Normally Open Fail Open 1 VDC 2 VDC 4mA Master Valve Open Spring Fails Master Valve OPEN NO FC Normally Open Fail Closed 1 VDC 2 VDC 4mA Open Spring Fails Valve CLOSED NO FC Normally Open Fail Closed 1 VDC 2 VDC 4mA Maser Valve Open Spring Fails Master Valve CLOSED NC FO Normally Closed Fail Open 1 VDC 2 VDC 4mA Closed Spring Fails Valve OPEN NC FO Normally Closed Fail Open 1 VD
197. ronze Stainless Steel GROOVED END BODY Reduces the weight of the valve and makes it easier to install UPPER AND LOWER STEM BEARINGS Helps maintain constant low torque values for the life of the valve O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 16 F6 Series 2 Way Victaulic Butter y Valve Technical Data Service chilled hot water 60 glycol Flow characteristic modi ed equal percentage Controllable ow range 82 Sizes 2 to 12 Type of end tting grooved ANSI AWWA C606 Valve materials Body Body nish Disc Seat Shaft Bearing ductile iron ASTM A536 grade 65 45 12 black alkyd enamel electroless nickel coated ductile iron EPDM 416 stainless steel berglass with TFE lining Body pressure rating 300 psi Media temperature range 30 F to 250 F 34 C to 120 C Rangeability 100 1 Maximum close off pressure 200 psi Maximum velocity 20 FPS VIC 300 Masterseal as manufactured by Victaulic Company 200 psi 2 to 12 bubble tight shut off Long stem design allows for 2 insulation Completely assembled and tested ready for installation Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut off for liquids Typical applications include chiller isolation cooling tower
198. s COP Close Off Pressure stated in psi This is the maximum differential pressure the valve will close off against while maintaining a bubble tight seal All SY series actuators are NEMA 4X rated and include 2 auxiliary switches and a heater SHP Series Butter y Valves with Industrial Actuation Average Assembly Weights ACTUATOR NON SPRING RETURN Size Valve Model Max GPM COP SY2 110 SY3 110 SY4 110 SY5 110 SY7 110 SY8 110 SY9 110 SY10 110 SY11 110 ANSI 300 2 way 2 F650 300SHP 313 600 39 lbs 2 F665 300SHP 490 600 39 lbs 3 F680 300SHP 705 600 45 lbs 4 F6100 300SHP 1253 600 52 lbs 5 F6125 300SHP 1958 285 58 lbs 5 F6125 300SHP 1958 600 58 lbs 6 F6150 300SHP 2820 285 77 lbs 6 F6150 300SHP 2820 600 77 lbs 8 F6200 300SHP 5013 150 108 lbs 8 F6200 300SHP 5013 600 132 lbs 8 F6200 300SHP 5013 285 170 lbs 10 F6250 300SHP 7834 400 170 lbs 10 F6250 300SHP 7834 600 201 lbs 10 F6250 300SHP 7834 150 254 lbs 12 F6300 300SHP 11280 285 254 lbs 12 F6300 300SHP 11280 600 285 lbs 12 F6300 300SHP 11280 150 379 lbs 14 F6350 300SHP 15354 400 410 lbs 14 F6350 300SHP 15354 600 410 lbs 14 F6350 300SHP 15354 150 487 lbs 16 F6400 300SHP 20054 285 487 lbs 16 F6400 300SHP 20054 400 531 lbs 16 F6400 300SHP 20054 600 531 lbs 16
199. s 55s 2 0A 30 75 Hand Wheel 36kg 79 5 lb SY9 230 MFT 2000Nm 17800 in lbs 58s 70s 1 6A 30 50 Hand Wheel 56kg 123 5 lb SY10 230 MFT 2500Nm 22250 in lbs 58s 70s 2 0A 30 50 Hand Wheel 56kg 123 5 lb SY11 230 MFT 3000Nm 26700 in lbs 58s 70s 1 6A 30 50 Hand Wheel 56kg 123 5 lb SY12 230 MFT 3500Nm 31150 in lbs 58s 70s 2 2A 30 50 Hand Wheel 56kg 123 5 lb Technical Data Electrical connection conduit connector screw terminals Overload protection thermally protected 135 C cut out Motor protection H Class insulation SY 1 F Class SY 2 12 Gear train high alloy steel gear sets self locking Operating range SY 220 on off floating point SY 230MFT 2 10 VDC 4 20 mA 0 10 VDC Sensitivity SY 230MFT 0 4 mA 200mV Reversal hysteresis SY 230MFT 1 0 mA 500mV Feedback SY 230MFT 2 10 VDC Angle of rotation 90 Direction of rotation reversible Position indication top mounted domed indicator Internal humidity control resistive heating element Auxiliary switches factory set for 5 and 85 change of state SY1 2 SPDT min 1 mA 24 VAC max 3A 250 VAC SY2 12 2 SPDT min 1 mA 24 VAC max 5A 250 VAC Ambient temperature 22 F to 150 F 30 C to 65 C Humidity range up to 95 Housing type IP67 NEMA 4X Housing material die cast aluminum a lloy Agency listings ISO CE cCSAus SY 230V Series Non Spring Re
200. s an externally controlled failure point upon over torquing BLOW OUT PROOF SHAFT Solid shaft provides alignment and rigid support for disc PACKING GLAND Separate part from gland ange preventing uneven load distribution against packing BEARINGS Both above and below the disc bearings are of composite design PTFE bonded to epoxy glass lament wound ring Used to align shaft with high capacity low wear and low friction coef cient DISC SPACERS Disc is centered by use of thrust spacers around shaft in sizes 2 to 5 Disc position stops or thrust bolt arrangements are used for larger valve sizes BODY ANSI B16 34 design in either wafer or lug con guration DISC 360 uninterrupted spherical edge for sealing Pro le is designed for maximum ow and equal percentage control RETAINER RING Retains seat in valve Standard surface nish is 125 to 200 AARH and is compatible with both standard gaskets and spiral wound gasket designs Outside diameter is recessed within gasket sealing surface to prevent external leakage O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 21 Average Assembly Weights ACTUATOR NON SPRING RETURN SPRING RETURN ELECTRONIC FAIL SAFE Size Valve Max GPM COP GMB X 2 GMB X 2 AF GK 2 GK ANSI 150 2 way 2 F650 150SHP 313 150 24 lbs 2 F650 15
201. s to use rigid type couplings for connecting the valve to the piping Pressure Drop psi 10 10 100 1000 10000 1 0 1 0 01 2 60 3 mm 2 1 2 73 0 mm amp 76 1 mm 3 88 9 mm 4 114 3 mm amp 108 0 mm 5 141 3 mm 133 0 mm amp 139 7 mm 6 168 3 mm amp 165 1 mm amp 159 0 mm 8 219 1 mm 10 273 0 mm 12 323 9 mm B D A C A D C 92 12 3 627 B 192 7 559 115 6 4 551 Flow Rate GPM Dimensions A D C 92 12 3 627 B 213 51 8 406 97 99 3 858 F7 Series 3 Way Victaulic Butter y Valve O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 20 Features and Bene ts SHP Series High Performance Butter y Valves Belimo SHP Series Butter y Valves are designed for use in ANSI Class 150 and ANSI Class 300 piping systems and are supplied in standard lug style body designs Valve Design Features Unique seat and disc design provides Bi Directional bubble tight shutoff at rated pressure temperatures The Soft Seat design creates a self energized seal in vacuum to low pressure applications Under high pressure conditions the seat is also designed to permit con ne and direct movement of the seat against the disc edge up to the full ANSI Class 150 or 300 Cold Working Pressures The
202. se Only Power Supply Com Power Supply Hot 24V AC DC Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal 33 Control Signal SYx 24MFT Address Adaption PC Tool Service Jack G PE Y1 Y2 34 36 Power Supply Com 120v N 230v L1 Power Supply Hot 120v H 230v L2 1 Y U5 C1 2 C2 B A 1 9 8 10 3 2 Internal Use Only Internal Use Only Internal Use Only Not Used Control Signal Not Used Internal Use Only Internal Use Only Internal Use Only Internal Use Only Internal Use Only Feedback Control Signal Feedback Signal Feedback Signal Control Signal SYx 230MFT Address Adaption PC Tool Service Jack SYx 120MFT L N G PE Y1 Y2 34 36 W547_2_11 Wiring for Control Valves Proportional 24V 120 230V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 55 SY Actuator Wiring Diagram SY1 5 24 Multiple Wiring SY1 12 110 220 Multiple Wiring Observe class 1 and class 2 wiring restrictions Transformer sizing SY actuator draw X 1 25 safety margin Ex SY2 24 requires 3 0A x 1 25 3 75A 3 75A X 24 VAC 90VA Transformer Indicates an action or condition that may cause irreversible damage to the actuator s or asso
203. sed as a disc position stop if the disc contacts the Overtravel Stop this means it has rotated beyond the seat 4 The SHP valve is bidirectional but the preferred installation position is with the seat in the upstream position SUS Note the arrow on the metal tag attached to the valve body Safety Precautions 1 Be sure the line is depressurized and drained 2 Be sure of the pipeline media Proper care should be taken for protection against toxic and or flammable fluids 3 Never install the valve without an Operator Manual or Automatic already attached to the valve shaft 4 Never remove the Operator from the valve while the valve is in the pipeline under pressure 5 Always be sure that the disc is in the full closed position before installing the valve 6 Take care in handling the valve if you treat it like a machine it will operate like a machine if you treat it like a piece of pipe it may work like a piece of pipe Flange Compatibility The SHP valve is designed to fit between flanges as follows ANSI Class 150 2 to 24 MSS SP 44 Class 150 30 to 48 ANSI B16 47 Class 150 A Flanges ANSI Class 300 2 to 24 MSS SP 44 Class 300 30 ANSI B16 47 Class 200 A Flanges Gasket Compatibility The SHP valve is designed to accommodate the use of standard fiber gaskets such as non asbestos flexible graphite asbestos or equivalent gasket materials of 1 16 or less meeting the dimensional
204. ss Adaption Y1 Y2 Address Adaption Y1 Y2 33 35 36 33 35 36 33 35 36 W550_2_11 Equipment damage Power consumption and input impedance must be observed Isolation relays are required in parallel applications The reason parallel applications need isolation relays is that the motor uses two sets of windings one for each direction When one is energized to turn the actuator in a specific direction a voltage is generated in the other due to the magnetic field created from the first It s called back EMF This is OK with one actuator because the voltage generated in the second winding isn t connected to anything so there is no flow it has no magnetic effect on the motor On parallel applications without isolation this EMF voltage energizes the winding it is connected to on the other actuators in the system the actuators are then trying to turn in both directions at once The EMF voltage is always less than the supply voltage due to the resistance of the windings so while the actuator still turns in the commanded direction the drag from the other reduces the torque output and causes overheating Wiring for Control Valves Proportional Multiple Wiring 24V O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 58 Indicates an action or condition that may cause irreversible damage to the actuat
205. stem Positive Locking Switch Cams Switch Cams Easily Accessible Field Wiring Terminal Field Wiring Terminal ed Housing NEMA 4X Rate NEMA 4X Rated Housing SY Series Actuators Belimo s SY series electric actuators have been designed to mate with our HD U Grooved and SHP series butterfly valves and other quarter turn valve applications The patented gear drive mechanism provides for efficient smooth operation while allowing easy manual override at any time Drawing upon years of experience in the actuation industry we have incorporated the most desirable features into the SY product range All units have NEMA 4X ratings easily visible position indicators international standard ISO5211 mounting systems internal thermal motor overload protection heater dual auxiliary Form C switches and easily accessible wiring termination points Wiring diagrams included in all printed documentation are also affixed to the outside of the housing on the permanently attached product label The units are easily visible in mechanical rooms with theeir characteristic Belimo Orange color Torque ranges are available from 310 to 31 150 in lbs O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 43 Application The SY actuators are NEMA 4X rated and designed to meet the needs of HVAC and Commercial applications Offered on Belimo stand
206. t and pipe scale or welding slag that could damage the seat and disc sealing surfaces 3 Actuators should be mounted on the valve prior to installation to facilitate proper alignment of the disc in the valve seat 4 The valve should be in the closed position Make sure the open and closed positions of the actuator correspond to the counter clockwise to open direction of rotation of the valve 5 Cycle the valve to the fully open position then back to the fully closed position checking the actuator travel stop settings for proper disc alignment 6 Check the valve identi cation tag for valve class materials and operating pressure to be sure they are correct for the application WARNING Personal injury or property damage may result if the valve is installed where service conditions could exceed the valve ratings 7 Check the ange bolts or studs for proper size threading and length REMEMBER Install the valve with the disc in the full closed position using the appropriate ange gaskets on BOTH valve ange faces Valve Installation Procedure The SHP High Performance Butter y Valve can be installed in the pipeline with the shaft in the vertical horizontal or other intermediate position Based on applications experience however in media with concentrations of solid or abrasive particles or media subject to solidi cation buildup valve performance and service life will be enhanced by mounting the valve with th
207. the BFV seat or disc edge which will prevent the valve from providing tight shutoff In such cases seat replacement may be necessary Packing Replacement 1 Remove the handle or actuator and the mounting hardware from the valve 2 Remove the gland ange nuts and lock washers 3 Remove the gland ange and gland 4 Replace the old packing with new packing Correct packing selection is important On larger valves it may be necessary to compress each stem seal into the stuf ng box before adding the next one 5 Reinstall gland gland ange lock washers and nuts 6 Tighten the gland ange nuts evenly to torque speci ed in Table 1 7 Operate the disc several times 8 Reinstall the handle or actuator and mounting hardware 9 Set the actuator stops Table 1 Valve Size in Torque in lb 2 to 8 25 10 to 12 35 14 to 20 50 24 to 30 75 36 to 48 100 End Cap Seal Replacement where applicable 1 Remove the end cap bolts and lock washers 2 Rotate the end cap to break the seal then pull the cap out 3 Remove the old seal 4 Clean the body and end cap prior to installing the new seal 5 Slide the new seal into place then guide the end cap into the body 6 Align the bolt holes and reinstall the lock washers and bolts 7 Tighten the bolts evenly to the torque speci ed in Table 2 Table 2 Valve Size in Torque in lb 2 to 8 50 10 to 12 80
208. turn Actuator Technical Data 230 VAC O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 46 D A B C A A A B B B C C C D D SY 1 SY 9 12 SY 7 8 SY 2 6 MODEL DIM A MAX Add to Dim A for cover removal DIM B DIM C MAX DIM D Inches mm Inches mm Inches mm Inches mm Inches mm SY1 6 10 155 3 94 100 4 25 108 8mm SY2 3 10 04 255 7 48 190 7 87 200 12 99 330 7 87 200 SY4 6 12 40 315 8 86 225 9 21 234 14 96 380 11 81 300 SY7 8 16 54 420 8 86 225 9 21 234 17 72 450 13 39 340 SY9 12 23 23 590 8 86 225 10 24 260 18 50 470 13 78 350 Note indicates range of actuator i e SY2 3 SY 2 and SY 3 SY Series Non Spring Return Actuator Dimensions O50904 02 12 Subject to change Belimo Aircontrols USA Inc 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 47 Wire Size vs Length of Run for SY Series Actuators The NEC mandates that 24 VAC over 100 VA power requires CLASS 1 wiring conduit Local codes may vary Do NOT mix CLASS 1 amp CLASS 2 circuits in the same conduit Generally 24 VAC actuators over 100 VA should be changed to 120 VAC models SY1 SY2 SY3 SY4 SY5 Amps Amps Amps Amps Amps wire gauge 1 8 3 3 6 6 5 MAX Dista
209. urned off The battery system automatically generates modi ed sine wave line voltage to provide power for the actuator The blue BAT CHARGING indicator light is turned off and the yellow B U POWER indicator light is turned on The FAIL POSITION SELECT switch becomes active and depending on its position drives the actuator either fully open or fully closed During this mode of operation the incoming proportional signal is irrelevant The battery system will provide ample power to drive the actuator more than 5 full torque cycles However once the actuator reaches its end of travel limit switch power drain from the back up system is reduced to the requirements of the yellow B U POWER indicator light After 15 minutes the battery system turns itself off and waits for the mains power to return The gear train design of the SY actuator provides automatic locking of the actuator position after the battery system shuts down Normal operation is resumed when mains power returns 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 95 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Key Access and Status Viewports Key Access and Status Viewports Battery System Status Indicators Battery System Status Indicators All Connections to APC Backup are Modular APC Backup are Modular Connection to PCB Interface Connection to PCB Interface SIZING AND PERFORMANCE CHART Actuator Mode
210. urns whichever occurs rst Simple User Interface Indicator lights visible through the viewport on the front and side of the control cabinet give status indication of mains power back up system charging and fail safe operation The NSV series is powered from building power and all power and logic interface wiring passes through the control cabinet There are two different series produced one is used for actuators which operate under 2 position or on off control schemes while the second series is used for actuators operating under proportional control schemes Various models are available within these two series to provide the most cost effective and ef cient means of providing fail safe operation for these actuators NOTE Universal Power Supply must be removed from cabinet to access the battery Battery must be connected to the wire harness to activate the Universal Power Supply NOTE Universal Power Supply must be turned on to charge the battery 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 93 O50904 02 12 Subject to change Belimo Aircontrols USA Inc FIELD LOGIC VOLTAGE A C LINE A BACK UP SYSTEM CABINET FIELD WIRING E D F C CLOSE OPEN B 4 6 3 5 1 7 TB GRN AG M2 A8 M3 H N G TB1 CLOSE OPEN NEUTRAL HOT L1 L2 GND ACTUATOR WIRING NO NC NC COM SWITCH 4 SCREW NO NO
211. ve ratings 5 Check the ange bolts or studs for proper size threading and length 6 These valves are designed to be installed between ASME ANSI Class 125 150 anges 7 Carefully follow installation using welded anges on page 82 of this document 8 Follow ASME ange alignment standards SECTION 335 1 1 ALIGNMENT a PIPING DISTORTIONS Any distortion of piping to bring into alignment for joint assembly which introduces a detrimental strain in equipment or piping components is prohibited b FLANGE JOINTS Before bolting up ange faces shall be aligned to the design plane within 1 16 ft measured across any diameter ange bolt holes shall be aligned within 1 8 maximum offset 9 When observed during assembly the ange faces shall be parallel within 1 degree and the force required to align pipe axes shall not exceed 10 lb ft per inch of NF bolts and nuts shall be fully engaged 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 113 O50904 02 12 Subject to change Belimo Aircontrols USA Inc Valve Installation Procedure Position the connecting pipe anges in the line to insure proper alignment prior to valve installation Spread the pipe anges apart enough to allow the valve body to be located between the anges without actually contacting the ange surfaces Exercise particular care in handling the valve so as to prevent possible damage to the
212. way Spring Non Spring Electronic Fail Safe 115 44 2 50 F650HDU AF Series AM Series SY Series 196 75 2 65 F665HDU 302 116 3 80 F680HDU 600 230 4 100 F6100HDU GM Series GK Series 1022 392 5 125 F6125HDU 1579 605 6 150 F6150HDU DR DKR 3136 1202 8 200 F6200HDU 5340 2047 10 250 F6250HDU 8250 3062 12 300 F6300HDU MOD ON OFF Valve Size Cv 10 20 30 40 50 60 70 80 90 F650HDU 2 115 06 3 7 15 27 44 70 105 115 F665HDU 2 196 10 6 12 25 45 75 119 178 196 F680HDU 3 302 20 9 18 39 70 116 183 275 302 F6100HDU 4 600 30 17 36 78 139 230 364 546 600 F6125HDU 5 1022 50 29 61 133 237 392 620 930 1022 F6150HDU 6 1579 80 45 95 205 366 605 958 1437 1579 F6200HDU 8 3136 2 89 188 408 727 1202 1903 2854 3136 F6250HDU 10 5340 3 151 320 694 1237 2047 3240 4859 5340 F6300HDU 12 8250 4 234 495 1072 1911 3062 5005 7507 8250 800 543 9038 USA 866 805 7089 CANADA 203 791 8396 LATIN AMERICA CARIBBEAN 8 F6 Series 2 Way HDU Butter y Valve Resilient Seat 304 Stainless Disc Maximum Dimensions Inches Valve Size Cv 90 Cv 60 A B C D Max BHC No of Holes Lug Bolt Actuator Close Off PSI 2 115 44 1 65 9 00 9 00 19 50 4 75 4 5 8 11 UNC AF 50 Spring Return