1. Industrielle Automation J 6 a oo Via fk jal Zei HE gen Re ann pw gt User manual BLCDN 6M12LT 2RFID S 8XSG PD Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A Edition 2011 3 15 All brand and product names are trademarks or registered trade marks of the owner concerned Hans Turck GmbH Mulheim an der Ruhr All rights reserved including those of the translation No part of this manual may be reproduced in any form or processed duplicated or distributed by means of electronic systems without written permission of Hans Turck GmbH amp Co KG Mulheim an der Ruhr Subject to alterations without notice 2 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e Witzlebenstra 3e 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 1 General SION ul EE 4 Tel BEfOF Mie INS CaM All OMS ERE m kar n a l a a aa a ko a kt ep pk a a once beki 4 2 General EE 5 2 1 Description of symbols Used 1 liiis eiieeeeeeieeeeee nenne nnne n nnn nnns nnn nnus nean suse nass sns n n nessun n nasus sen n nsns nnn nnn nnns 5 A8 2221 62 j 0 21 0 USE vive kanari 5 2 3 Notes Concerning Planning Installation of this Product sise 5 3 WOU UON a EE E een a ms l ke tn ee anne et 6 3 1 BL compact H
2. Industr A General safety notes 1 1 Before the installation 4 32011 Disconnect the power supply of the device Ensure that devices cannot be accidentally restarted Verify isolation from the supply Earth and short circuit Cover or enclose neighboring units that are live Follow the engineering instructions of the device concerned Only suitably qualified personnel in accordance with EN 50 110 1 2 VDE 0 105 Part 100 may work on this device system Before installation and before touching the device ensure that you are free of electrostatic charge The functional earth FE must be connected to the protective earth PE or to the potential equalisation The system installer is responsible for implementing this connection Connecting cables and signal lines should be installed so that inductive or capacitive interference do not impair the automation functions Install automation devices and related operating elements in such a way that they are well protected against unintentional operation Suitable safety hardware and software measures should be implemented for the I O interface so that a line or wire breakage on the signal side does not result in undefined states in the automation devices Ensure a reliable electrical isolation of the Ensure a reliable electrical isolation of the low low voltage for the 24 volt supply Only use power supply units complying with IEC 60 364 4 41 VDE 0 100 Part 410 or HD 384 4 41 S2 Dev
3. 1 inactive The outputs bit 0 channel O to bit 7 channel 7 have to be retriggered in case of an overload 0 inactive 1 active Activates the output at this channel bit 0 channel 0 to bit 7 channel 7 0 inactive 1 active Sets the input filter from 0 25 ms to 2 5 ms bit 0 channel 0 to bit 7 channel 7 0 disabled 1 enabled Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com
4. DSI to DeviceNet DeviceNet Safety Scanner DeviceNet to SCANport Dodge EZLINK General Purpose Discrete 1 0 Generic Device Human Machine Interface Inductive Proximity Switch Limit Switch Motor Overload Motor Starter Photoelectric Sensor PointBus Motor Starter Rockwell Automation miscellaneous SCANport Adapter Safety Controllers Safety Discrete 1 0 Device Smart MCC Specialty LO Vendor Rockwell Automation Allen Bradley Rockwell Automation Dodge Rockwell Automation Electro Craft Motion Control Rockwell Automation Rekance Electric Rockwell Automation Ertek Ird Intl Rockwell Automation Sprecher Schuh Turck Inc Communication Adapter d BL20 E GW ON acon Industr A BL20 E GW DN BLCDN 00 01 3 BLCDN RE General Parameters 110 Data EDS Fie Select the parameter that pou want to configure and inibate an action using the toolbar Groups e 9 Ets DZ P Parameter Current Value GWscheduledd disabled S 9 COSdata mapping standard Baud Rate 125 kbps AutoBaud disabled I MAP GW statu 2 bytes I MAP polled iro 0 bytes I MAP summariz 0 bytes I MAP schedule 0 bytes COS MAP COSJ 0 bytes Q MAP GW cont 2 bytes Q MAP polled o 0 bytes siot count 0 seti BLC 8X5G PD lt FMPTY BASF LZ gt Abbrechen bemehmen Hite sss ss sts Gr fe P Gr fie Gr Gr v w Fi M 4 b M Graph Spreadsheet Master Slav
5. 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 4 Technical data Type Ident No Supply voltage Admissible range Voltage supply connection Power loss typical Nominal voltage Vj Nominal voltage Vo Max sensor supply lsens Max load current I Fieldbus transmission rate Adjustment transmission rate Fieldbus addressing range Fieldbus addressing Service interface Fieldbus connection technology Fieldbus termination Digital inputs Input type Type of input diagnostics Sensor supply Low level signal voltage High level signal voltage Active level IC signal current Signal voltage inactive level Input delay Digital outputs Output type Type of output diagnostics Output current per channel Output voltage Output delay Load type Load resistance resistive Load resistance inductive Lamp load Switching frequency resistive Inductive switching frequency Switching frequency lamp load Short circuit protection Technology Signal type Number of channels Sensor supply Simultaneity factor Cable length Electrical isolation Number of input bytes Number of output bytes Operating temperature Storage temperature Extended vibartion resistance up to 20 g at 10 to 150 Hz BLCDN 6M12LT 2RFID S 8XSG PD 6811049 24 VDC 11 30 VDC 2 x M12 4 pin lt 1W 24 VDC 24 VDC 4A 4A 125 500 kbps auto detection 0 63
6. 64 80 Programmable MACID 81 Vendor Specific 2 decimally coded rotary switches RS232 interface 2 x M12 5 pin external pnp channel diagnostics 24 VDC 100 mA short circuit limiting lt 4 5 VDC 7 30 VDC lt 1 5 mA 2 1 3 7 mA 0 25 or 2 5 ms pnp channel diagnostics 0 5 A 24 VDC 3 ms resistive inductive lamp load gt 48 Q 1 2H 3W 200 Hz 2Hz lt 20 Hz yes Simple RFID Interface 2 0 5 A per channel short circuit proof 1 Industr A 99 50 m isolation of electronics and field level via opto couplers 26 26 40 70 C 40 85 C firm mounting on base plate or machine 71320 FOte GON GIASSmbH amp Co KG e D 45472 M lheim an der RI PA Kitziebenstrake 7 Tel 0208 4952 0 Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 8 32011 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 4 Technical data Operating temperature 40 70 C housing material Glass filled nylon nickel plated brass connec tors Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 5 Fieldbus and UO connections 5 1 Pinning and wiring diagram Fieldbus accessories Pin configuration DeviceNet fieldbus cable example RSC RKC572 2M Ident no 6
7. 603629 ao D ao 2 D aARONM Hon H oH d DO KI ARON Hou Hog og OO lt lt Slot 1 RFID Connectors S2500 Matching connection cable for example RK4 5T 5 RS4 5T S2500 Ident no 6699201 lt L 2 o E o 5 4 o O O AUN Slot 2 digital XSG channels Pin configuration 1 VSENS 2 Signal B 3 GND 4 Signal A 5 Voltage supply 9 32011 Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 6 Commissioning All new settings become valid only after a 6 1 Address setting The DeviceNet address setting at the mod ule is done via the two decimal rotary cod ing switches under the protective cover De viceNet allows a maximum of 64 00 to 63 addresses MAC IDs to be assigned Each ad dress may be allocated only once in the entire bus structure 6 2 Setting the transmission rate The module provides automatic transmission rate detection The bit rate can be changed via the standard ODVA DeviceNet Class Class 0x03 In stance 0x01 Attribute Oxx02 Terminating resistor female 6 3 Field bus termination If the module is used as the first or the last sta tion in the bus communication the fieldbus line has to be terminated using a terminating resis tor The module offers no internal b
8. Hz Data communication from to tag active Reon ror in the RW head Po REDS FLASSHING 2 Hz Short circuit in the transceiver supply D1 LED also reports gateway diagnostics 8 3 1 0 LED Status Slot 2 Ip eoor fstas eege Jn OFF No diagnostics active Station error module bus communication failure FLASHING 0 5Hz Any diagnostics active XSG channels O Channel status x O OFF O FF GREEN N Channel status x 1 ON eon nertarautatoupun Po RED FLASHING 2 Hz Short circuit sensor supply D2 LED also reports gateway diagnostics 13 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 9 Mapping and diagnostics 9 1 1 0 and Diagnostic Data mapping INPUT BYTE Ier jBit6 Bit Di Bit3 Bit2 Di erg channel O n e ooo un E ror Code n 8 Reserves NN READ DATA 8 Byte channel 1 Error Code Ju Jinan ole L 6 reserve 8 Byte Dag 26 Module number reporting diagnostic data Replace sta N A Diag active Reserved WI D ee In case of Reserved XCVR Reserved PS OFF CH 0 slot 1 ref byte 26 un Reserved XCVR Reserved PS OFF ERN RFID diag In case of Reserved Over Over slot 2 current current esee 12 16 11 15 Over Over Over Over O
9. ameter RFID S Bypass Ch1 in ms 7C 1 73 and RFID S Bypass Ch2 in ms 7C 1 43 default setting 10 3 8XSG Parameters Parameter 8XSG PD invert input 75 1 7F 8XSG PD output auto recovery 75 1 85 8XSG PD output re triggered recovery 75 1 89 8XSG PD enable output 75 1 8B 8XSG PD enable 2 5ms input filtering 75 1 8F default setting Description Bypass time of the transceiver in steps of 4 milliseconds Values from 0 0 ms to 255 1020 ms Please maintain the default setting 0 of this parameter if the system startup is done without the error message Dwell time of the Tag in the detection area was not long enough for successful command pro cessing Check if the application makes it possible to set the recommended minimum distances to re duce the speed or the transferred data amount The information about the recommended and the max imum distances can be found in the Installation manual D101583 pdf for the RFID system in the chap ter operating data If you are not able to respect the required distances or if the error is still sent due to external influences even if these distances are respected this parameter has to be set to an adequate value Description The input signal is inverted bit O channel 0 to bit 7 channel 7 0 normal 1 inverted The outputs bit 0 channel 0 to bit 7 channel 7 switch on automatically after an overload 0 active
10. e Configuration A Diag gt Message Code Date Description A onet 0005 07 07 2008 10 12 51 Hans Turck GmbH amp Co KG BLCDN 6 6 Vendor Specifc Classes VSCs BL compact modules for DeviceNet are based on the communications adapter profile according to ODVA specifications Rel V2 0 ODVA Open DeviceNet Vendor Associa tion NOTE Copy protection activation for RSNetWorx was not detected The software wil run in DEMO Mode Offline Besides the standard DeviceNet classes this module supports the following Vendor Specific Classes VSC 100 64h Gateway Class 101 65h Terminal Slot Class 102 66h Process Data Class VSCs for the respective I O channels 11 32011 For more detailed information about the PLC configuration of TURCK DeviceNet products or the Vendor Specific Class es of the I O channels please read for example the respective BL67 manual D300528 pdf which can be downloaded from www turck com Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 7 The I O ASSISTANT The configuration software I O ASSISTANT Industr A B PACTware 01 Intern 4A1 V I Parameterization supports you in planning and implementation Of 5 fait wew project Device Extras Window Hep an I O system No matter if you are onl
11. es are connected to fieldbus gateways which fulfill application specific I O tasks Such a fieldbus node can take one gateway with up to 32 extension modules max 512 I O points For applications with low signal density and limited mounting space BL compact is an efficient alternative because basically all BL67 I O signals are also available in BL compact The modular principle The BL compact devices provide three basic functions in a single housing Fieldbus connection I O signal and connector Depending on the housing style one or two I O modules can be housed The smaller versions e g M12S and M12MT can link any BL67 electronic module each to PROFIBUS DP or DeviceNet The bigger versions e g M12LT have space for two BL67 electronic modules making the possibilities of signal combination nearly infinite v M f wa a a mm ts Pa EI Ei n f D NM NOTE The l O system BL compact does not require mounting in an extra housing It was specially designed for the harsh industrial en vironment and for direct mounting on the machine and in the process The system is extremely robust and protected against dirt dust and the most liquids through its high degree of protection However it is not suited for the following applications high pres sure jet cleaning 100 humidity out door installation or permanent operation in liquids 6 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel
12. gh maintenance guarantee the trouble free and safe operation of these devices WARNING The devices described in this manual must be used only in applications prescribed in this manual or in the respective technical descriptions and only with certified components and devices from third party manufacturers 2 3 Notes Concerning Planning Installation of this Product WARNING All respective safety measures and accident protection guidelines must be considered carefully and without exception 5 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 3 Introduction 3 1 BL compact High signal variety in a compact design For the first time BL compact provides a product family of IP67 fieldbus devices that can meet any requirement in the I O level in terms of signal type and connectivity Until now compact fieldbus stations were applied to process only digital fieldbus signals BL compact now allows a wide range of I O tasks to be implemented outside of the control cabinet in a compact design with virtually any signal combination The basic concept With the modular concept of the BL67 system by TURCK a fieldbus node can be installed outside the control cabinet using any signal combina tion For this purpose passive base and active electronic modul
13. iations of the mains voltage from the rated value must not exceed the tolerance limits given in the specifications otherwise this may cause malfunction and dangerous operation Emergency stop devices complying with IEC EN 60 204 1 must be effective in all operating modes of the automation devices Unlatching the emergency stop devices must not cause restart Devices that are designed for mounting in housings or control cabinets must only be operated and controlled after they have been installed with the housing closed Desktop or portable units must only be operated and controlled in enclosed housings Measures should be taken to ensure the proper restart of programs interrupted after a voltage dip or failure This should not cause danger ous operating states even for a short time If necessary emergency stop devices should be implemented Wherever faults in the automation system may cause damage to persons or property external measures must be implemented to ensure a safe operating state in the event of a fault or malfunction for example by means of separate limit switches mechanical interlocks etc The electrical installation must be carried out in accordance with the relevant regulations e g with regard to cable cross sections fuses PE All work relating to transport installation commissioning and maintenance must only be carried out by qualified personnel IEC 60 364 and HD 384 and national work safety regulations All shroud
14. igh signal variety in a compact design ssssssssssssssrreensrreensereeneseeenseseeennsneennss 6 Lee a Pos L 0 rire PEUT 7 Fieldbus and NO CONN G HO NS iii a ot a men seems ee annees encens 9 S1 loin Une snd Wining YO YON ANN EE H NAIA SONA Le BE 10 51 AUTOS d uo EE 10 6 2 SEMING ING ran SAIS SION L AL ki zi awa ata kl ek ali all a ka kt a kt ae n EVE a a a a en a n a ti n a ee a SCR a a pa ka e a 10 SOME dU T FMI YO A tet t po e e e ak e E n a a a kk a a kk ke tam an t 10 64 Servie METTaACE EE 10 69 PLC CO UU a EE 11 616 Vendor Specife Classes V SES hunsar a aaa ta Ea kn EU a RU SEM MR ana ne die one a 11 f Jne OS TAN H RE 12 al FD ELE 9 d 12 o LED OSCAR ee RE e n D 13 OL Sions RN REN 13 B2 WO LED Stats S 1 EE 13 Bo TOCED EEN 13 9 Mapping and CIaGQnOStiCs cccccceeceeeeeeeeeeeeceeseneseneceneeeneceeeeeeecneseneeeneeenseaneeensonssoeesenesenenens 14 9 1 NO and Diagnostic Data Mapping EE 14 92 REID S DIaqgn s y MES LE 15 23 BASG Diagnostic M S SAG EE 16 TU Gu een al ki ak ik a af HER ka n S ni e ki kk e a ee VEU ERU kai a ke 17 10 1 DEVICENET E ET 17 102 RFID Se PAP AME ENS ea a a e n a a ae eo kk a D ot ka en a kek en ra dni ne a COUR 17 TOS SOS Pal E 17 3 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Industr A Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 1
15. ine or offline the soft ware simplifies the configuration and parame terizsation of the modules The l O ASSISTANT is also extremely helpful in system set up and testing Gen LIBLCDN 4M125 4AI VT ve Q1 Intern 4AI V T jw L BLCDN 4M125 8XSG PD P Device for 7 1 FDT DTM The system configuration parameterization and diagnostics are done via graphical interfaces based on FDT DTM technology The DTMs can be integrated in any FDT frame application for configuration commissioning ELCON 41M125 4AT VI BLCDN 4M125 8XSG PD DS d 82290 Gag anze ogue inputs Offline parameterization pr ui 9 us Value x Device Version 1 0 0 2007 10 10 1 0 0 2007 10 10 1 0 0 2007 10 10 1 0 0 2008 10 29 1 0 1 2007 10 10 1 0 0 2008 01 24 1 0 0 2007 10 10 1 0 0 2007 10 10 1 0 0 2007 10 10 1 0 0 2007 10 10 Vendor BL Service BL67 Ik Turck BL Service BL67 Mk Turck BL Service EL Servi Turck BL Service EL Servi Turck BL Service EL Servi Turck BL Service EL Servi Turck BL Service BL Servi Turck BL Service EL Servi Turck BL Service EL Servi Turck BL Service BL Servi Turck BL Service BLC Mo Turck BL Service BLC Mo Turck DTM specific DTM specfic 1 0 0 2008 11 06 1 0 0 2008 11 06 and maintenance The I O ASSISTANT and the DTMS are avail able free of charge on www turck com Software functions m Supporting software tool m Configuration parameterization and com m
16. issioning of BL Compact modules vi a DTM technology m Import of BL Compact DTM files m Offline planning and configuration of BL67 BL20 and BL compact I O modules m Reading and setting of process data m Commissioning help for testing the wiring and sensors without PLC m Automatic documentation of configured TURCK systems 12 32011 lt FixModData FWDownloadFiles binary FWDownlosdBinaryStarte 65536 FWWait DWLe S000 Proglde gwBlDtm Main2 integer data forma fiacneshie KA Cf Disconnected Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 8 LED description 8 1 Stations LED Status Ip on oo on oo Jn C EE oo REDON Yow power an station enor RED FLASHING THz NO module configuration error RED JELASHING 4 H2 No VO module bus communication Jemen Jo station ok CERN SLASHING Fowmodeadwe CE jor ooo il SOS S LASHING 1 Hz FLASHING 1 Hz One or more I O idle One or more UO error FLASHING One or more I O faulted 8 2 I O LED Status Slot 1 1 exer ae Seege OFF est DI ON Station error module bus communication failure DI FLASHING 0 5Hz Any diagnostics active RWO RW1 OFF No tag present no diagnostics active DREN ON a presen GREEN FLASHING 2
17. load at output x The channel is switched off automatically Whether it is switched on again automatically or not depends on the parameter settings for the channel see parameters 16 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 17 32011 Compact BLCDN 6M12LT 2RFID S 8XSG PD 10 Parameters 10 1 DeviceNet Parameters Industr A Gateway parameters fieldbus communication The module provides the following parameters to configure the DeviceNet communication The parameters are described in module specific EDS files which allow text based parameterization in EDS interpreting configuration tools like RSNetworx from Rockwell Automation for example For a parameterization via Class Instance Attribute C A please find the necessary information in brackets hexadecimal format Parameter Baud rate 03 01 02 AutoBaud Description MAC ID 03 01 01 0 to 63 0 125 kbps 1 250 kbps 2 500 kbps 0 disable 1 enable 03 01 64 on HO cnten timeout Defines the output behavior in case of I O connection timeout 64 02 73 BUS OFF irtp 0 switch outputs faulted 1 switch outputs off 2 hold outputs 0 holf CAN chip in BUS OFF state 1 reset CAN chip 03 01 03 default setting 10 2 RFID S Parameters Par
18. nsceiver is not connected correctly to the RFID module XCVR ON 1 The transmission between tag and tranceiver with 13 56 MHz is active 0 The transmission between tag and tranceiver with 13 56 MHz is not active TP TAG PRESENT 1 Tag detected in the transceiver air interface and it is recognized by the transceiver 0 No tag detected in the transceiver air interface or tag is not recognized by the transceiver TFR TAG FULLY READ 1 All memory areas on the tag have been successfully read 0 All memory areas on the tag have not yet been successfully read ERROR CODES Please read the detailed error code descriptions in the special DeviceNet documentation for the RFID system Additionally the module sends 4 byte 2 byte for each channel of diagnostic data which describe the status of the connected read write head Diagnostic message Meaning XCVR PS OFF Transceiver power supply turned off overload XCVR HDWR ERROR Transceiver hardware error XCVR PS ERROR Transceiver power supply error 15 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 9 Mapping and diagnostics 9 3 8XSG Diagnostic messages Diagnostic message Meaning Over current Ix Ix Short circuit or overcurrent at sensor supply A B C or D Over current O x Short circuit or over
19. s and doors must be kept closed during operation Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 2 General information This manual includes all information necessary for the prescribed product It has been specially conceived for personnel with the necessary qualifications A ATTENTION Please read this section carefully Safety aspects cannot be left to chance when dealing with electrical equipment 2 1 Description of symbols Used A WARNING This sign can be found next to all notes that indicate a source of hazards This can refer to danger to personnel or damage to the system hardware and software and to the facility This sign means for the operator work with extreme caution A ATTENTION This sign can be found next to all notes that indicate a potential hazard This can refer to possible danger to personnel and dam ages to the system hardware and software and to the facility NOTE This sign can be found next to all general notes that supply important information about one or more operating steps These spe cific notes are intended to make operation easier and avoid unnecessary work due to incorrect operation 2 2 Prescribed Use Appropriate transport storage deployment and mounting as well as careful operating and thorou
20. us terminating resistor The termination has to be done exter nally 6 4 Service interface In order to connect the service interface on the module with a PC and the I O ASSISTANT soft ware project planning and diagnostics soft ware a cable with a pin assignment different from the PS2 standard pin assignment has to be used el Ba el Be o e W Yo dean dean N e 0000o Service Industr A module restart RKE57 TR2 Ident no 6602629 Terminating resistor male RSE57 TR2 Ident no 6602308 10 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD 6 Commissioning 6 5 PLC configuration i File Edit View Network Device Diagnostics Tools Help The modules can be integrated into the De viceNet structure by means of module specif ic BL compact EDS files Commissioning in a configuration tool Registrate the EDS files in the PLC configura tion tool eg in RSNetWorX from Rockwell Au tomation The BL compact modules can now be found under TURCK Inc gt Communication Adapter Add the modules to your fieldbus line The EDS files can be downloaded from www turck com DA FAS SCS SUC SA SRR FE AF AE AF AP AS AS SSS A CELLIER DeviceNet 24 category AC Drive Barcode Scanner Communication Adapter DPI to DeviceNet
21. ver Over current current current current current current O6 O5 O4 O3 O2 O 1 XSG diag Reserved 31 Reserved ourPUT BYTE Bit pe DS Di its Bit2 Di Bit 14 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr Witzlebenstraf3e 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com www turck com Edition 2011 3 15 Compact BLCDN 6M12LT 2RFID S 8XSG PD Industr A 9 Mapping and diagnostics RFID XCVR NEXT TAG ID READ WRITE TAG INFO XCVR INFO RESET channel 0 2 1 0 irs ri 8 Address Tow bye an WRITE DATA 8 Byte Le 11 RFID len NEXT TAG ID READ WRITE TAG INFO XCVR INFO RESET channel 1 2 1 0 a adress righ byte L 6 Jee iow bye 8 Byte The scheduled diagnostic information changes every 125 ms between slot 1 and 2 if both slots send active diagnostics 9 2 RFID S Diagnostic messages The RFID S provides status information within the process data 3 bytes per channel Diagnostic message Meaning DONE 1 The system is not processing any commands and is ready to receive the next command 0 The system will ignore all incoming commands if DONE is false except the RESET com mand BUSY 1 The system is currently executing a command 0 The execution of the command has finished ERROR 1 An error occurred while executing a command 0 Errorfree execution of the demand XCVR CON 1 The transceiver is connected correctly to the RFID module 0 The tra