PARSTAT 2273 User Manual 11_04
Contents
1. Pe PARSTAT 2273 Research Advanced Electrochemical System Ext In E Monitor Monitor Cell Enabled ra Enable G CellOn Fig 6 PARSTAT 2273 Front Panel 3 2 2 1 Connectors CELL CABLE Connector and Cable The cell cable part no 223622 connects to the 10 pin CELL connector on the front panel via a LEMO style connector The connector is keyed so it can only be inserted the correct way To connect it grasp it by the grooved sleeve turn it so the red dot aligns with the red mark on the CELL connector this will ensure that the key aligns with the keyway and press it into place To disconnect it grasp the grooved sleeve and pull straight out At the other end of the cable are five color coded leads The color codes are Green Working electrode lead Red Counter electrode lead White Reference electrode lead Gray Sense electrode lead Black Ground In both potentiostatic and galvanostatic operation the RED pin plug connects to the counter electrode and the GREEN pin plug connects to the working electrode The reference electrode WHITE plugs directly into the pin jack socket and the black clip is ground The GRAY lead is the sense lead and connects to the working electrode The use of the black lead depends on a number of factors It is not ordinarily used with the PARSTAT 2273 although it is available if needed for special purposes such as supplying g
2. Common Mode Rejection e gt 80dB at 100 Hz e gt 60 dB at 100 kHz Input Impedance typically gt 10 in parallel with lt 5 pF 4 1 3 iR Compensation Positive Feedback Range 2000 MO to 2 depending on current range Current Interrupt 16 bit DAC potential error correction 4 1 4 Current Measurement Ranges 12 decades 2 A to 40 pA with internal gain applied Accuracy dc e 20uAto2A 0 496 full scale e 20nAand 1 pA ranges lt 0 5 e 2nX lt 0 75 Frequency Response small signal e 2mArange 3 dB at gt 1 MHz 1k source impedance e 20yArange 3 dB at gt 100 kHz 100k source impedance 4 1 5 Potential Current Control Digital Analog Converters DACs Bias DAC e Resolution 16 bits e Range potentiostat 10V e Range galvanostat 100 of full scale current Modulation DAC e Resolution 16 bits 17 4 1 6 Impedance Specification Frequency Range 10 uHz 1 MHz 4 2 Phvsical and Power Specifications Computer Interface Universal Serial Bus USB Weight 31 kg 68 Ibs Dimensions 50 8 cm W x 47 6 cm D x 22 9 cm H 20 in x 18 75 in x 9 in Power Requirements e 100 120 V AC or 220 240 V AC 50 60 Hz 600 W maximum EMI filtered per IEC 801 Overvoltage category II Pollution degree 2 The rear panel power entry module provides a standard IEC plug for connecting power cords that are compatible with local AC voltage outlets The power entry module lets you select the required input voltage and contains the
3. cord it should be an approved type with a standard IEC connector at one end for connection to the 2273 DANGER If itis necessary to replace the power cord or the power plug the replacement cord or plug must have the same polarity as the original Otherwise a safety hazard from electrical shock might exist that which could result in personal injury or death 2 2 Line Voltage and Fusing 2 2 1 Selecting the Line Voltage Before connecting any system components to the ac mains source consult the corresponding hardware manuals and make sure each component is configured for your ac line voltage CAUTION Your equipment can be destroyed if it is not set to the proper power line voltage The 2273 has a Corcom Power Entry Module on the lower left side of the rear panel The Corcom module Fig 3 contains the power connector a small removable drum for setting the line voltage and a line fuse The removable drum lets you configure the instrument for a nominal 100 120 220 or 240 V ac The module door has a small window that shows the line voltage setting now in use To change the ac input voltage Disconnect the instrument from the ac power source Use a small flat blade screwdriver or similar tool to pop open the module door Remove the plastic drum pinch the sides of the drum with your fingernails and pull or insert a flat blade screwdriver in the slot between the 120Vac and 240Vac settings and gently pry the drum loose
4. for the other leads Chapter 3 INSTALLATION 15 16 Other configurations and connections If your cell is a two terminal connection i e a battery or resistor connect both the green working and gray sense leads to either the anode or cathode and both the red counter and white reference leads to the remaining cathode anode There are some applications for which a four electrode configuration is required In this case the sense electrode serves as a second reference electrode useful for controlling the potential between the reference and sense for instance in controlling the potential across a membrane in an H cell setup After all other connections to the PARSTAT 2273 are completed you can turn on power to the instrument PARSTAT 2273 Hardware User s Manual 4 SPECIFICATIONS AND PINOUTS 4 1 Electrical Specifications Potentiostatic Circuitry 4 1 1 Power Amplifier Compliance Voltage 100 V Maximum Current 2A Rise Time lt 250 ns no load typical Slew Rate gt 15 V us no load System Performance e Minimum Time Base 20 us Minimum Potential Step 2 5 uV Noise and Ripple 50 uV rms typical Minimum Current Range 2 nA hardware Minimum Current Range 40 pA after 50X gain Minimum Current Resolution 1 2 fA 4 1 2 Differential Electrometer Input Bias Current 5 pA at 25 C Max Voltage Range 10 V maximum Input Voltage Differential 10 V Bandwidth 3 dB gt 15 MHz typical
5. e e dea atat 14 3 3 Connecting to the PC and Cell 6 LL 15 3 3 1 Connecting to the PC 000 15 3 3 1 1 Installing the USB Driver 0 0 00 eh 15 23 9 2 Connecting the Cells xr ERE Eder 15 4 SPECIFICATIONS AND PINOUTS 2 ehh 17 4 1 Electrical Specifications Potentiostatic Circuitry 17 44 41 Power Amplifier ise eie e x ee ere l eere xu ure RUE 17 4 1 2 Differential Electrometer 0 0 cc nee hes 17 4 1 3 iR Compensation 0 0 6 hrs 17 4 1 4 Current Measurement 000 ccc hh 17 Potential Current Control edea ia bhiet euwprbeic4d bnk eid ees baw oak elei 17 4 1 6 Impedance Specification nauau aanne 18 4 2 Physical and Power Specifications 00000 eee 18 4 3 Standard Environmental Conditions liliis 18 lii 4 4 AUXILIARY INTERFACE Pinouts PARSTAT 2273 Hardware User s Manual Safety Instructions and Symbols This manual contains up to three levels of safety instructions that must be observed in order to avoid personal injury and or damage to equipment or other property These are DANGER Indicates a hazard that could result in death or serious bodily harm if the safety instruction is not observed WARNING Indicates a hazard that could result in bodily harm if the safety instruction is not observed CAUTION Indicates a hazard that could result in
6. point in the electrochemical cell PS REF is W 8 GROUND 22 34 CURRENT RANGE ayh K WORKING VE AMP REPORT gt AMP POWER do o2 CELL SWITCH ELECTROMETER E REPORT SERIAL gt AT8S8252 325 kB 24 MHz EK COUNTER 8 REFERENCE 80 SENSE Fig 2 Galvanostat Mode Block Diagram 1 5 Polarity Convention The PARSTAT 2273 hardware follows the American polarity convention Positive current is cathodic that is a current is defined as positive if reduction is taking place at the working electrode Negative current is anodic that is a current is defined as negative if oxidation is taking place at the working electrode If the working electrode is driven positive with respect to the Chapter 1 INTRODUCTION equilibrium potential the resulting current is anodic If the electrode is driven negative with respect to the equilibrium potential the resulting current is cathodic In complex electrochemical systems there might be more than one equilibrium system Where this is the case either polarity with respect to the equilibrium potential could give rise to anodic or cathodic current according to the system s characteristics 1 6 Inspecting Your New Instrument As soon as you receive your new PARSTAT 2273 inspect it for shipping damage If any damage is noted immediately notify Princeton Applied Rese
7. precise dc voltage in the 10 V range This output can be used to control the rotation speed of rotating disk electrodes RDEs POWER AMPLIFIER MONITOR Output of the power amplifier divided by ten 100 V range of amplifier output gives 10 V POWER AMPLIFIER MONITOR output Output impedance is 50 Q Booster Interface The rear panel Booster Interface connectors and controls are shown in Fig 5 If a booster interface is not installed the holes will be unlabeled and covered with blanks CE Terminal block accepts a 10 AWG wire from the counterelectrode MODE BOOSTER INTERFACE BOOSTER E OUT l MON NORMAL Fig 5 Rear Panel Power Booster Interface WE Terminal block accepts a 10 AWG wire from the working electrode COM Terminal block accepts a 10 AWG ground return wire from the Power Booster OUT Terminal block accepts a 10 AWG output voltage wire from the Power Booster E OUT Rear panel BNC sends control signal telling the Power Booster what voltage to deliver PARSTAT 2273 Hardware User s Manual l MON Rear panel BNC accepts signal indicating the current being provided by the Power Booster NORMAL Switches between BOOSTER mode and NORMAL unboosted mode If you wish to use the 2273 without the Power Booster disconnect the cell cable from the Power Booster and connect the standard 2273 cell cable to the 2273 front panel 3 2 2 Front Panel The PARSTAT 2273 front panel is shown in Fig 6
8. property damage if the safety instruction is not observed In addition the following symbols may appear on the product AN DANGER High Voltage ATTENTION Refer to Manual Please read all safety instructions carefully and make sure you understand them fully before attempting to use this product Cleaning Instructions WARNING Using this instrument in a manner not specified by the manufacturer may impair the protection provided by the instrument To clean the instrument exterior e Unplug the instrument from all voltage sources e Remove loose dust on the outside of the instrument with a lint free cloth e Remove remaining dirt with a lint free cloth dampened in a general purpose detergent and water solution Do not use abrasive cleaners CAUTION To prevent moisture inside of the instrument during external cleaning use only enough liquid to dampen the cloth or applicator e Allow the instrument to dry before reconnecting the power cord TABLE OF CONTENTS lt vi Princeton Applied Research PARSTAT 2273 Advanced Electrochemical System PARSTAT 2273 Hardware User s Manual 1 INTRODUCTION The Princeton Applied Research PARSTAT 2273 offers compliance voltage up to 100 V available at the counter electrode 10 V scan ranges a 2 A current range the ability to make electrochemical impedance spectroscopy EIS measurements from 10 uHzto 1 MHz anda design that will sustain long term heavy load operation
9. 3A SMDE via a Model 507 Interface this signal controls the electrode s PURGE function in response to commands from the host PC set on the PreScan Definition page of the New Experiment Wizard 9 STIR This signal controls the Model 303 or 303A s STIR function in response to commands from an external computer set on the Cell Definition page of the New Experiment Wizard ltis assumed that the electrode is being used with a Model 305 stirrer Chapter 4 SPECIFICATIONS AND PINOUTS 20 PARSTAT 2273 Hardware User s Manual
10. 411 801 S Illinois Avenue FAX 865 483 2133 Oak Ridge TN 37831 ATTN Customer Service D CUSTOMERS OUTSIDE OF U S A To avoid delay in customs clearance of equipment being returned please contact the factory or the nearest factory distributor for complete shipping information Copyright 2004 Advanced Measurement Technology Inc All rights reserved Princeton Applied Research is a registered trademark of Advanced Measurement Technology Inc an ISO9001 2000 certified company All other trademarks used herein are the property of their respective owners TABLE OF CONTENTS Safety Instructions and Symbols ners hr rh Gleaning Instr ctlonis 2 hone Mead Do B A MER ats 1 INTRODUCTION acted nid dent net Us Rp re ded edet mega hdd died eap bud dedito ads 1 1 15 Applications isir atti ee ned et tine e casa des bed Grae end e ee aa epe eats 1 1 25 Boosterjinteta e i dics dede ant doe Nea e ode 2 1 3 Hardware and Software 0 ccc hme 2 1 4 PotentiostatiC GIrGUllEV 2 ete arte SE MER LEG S E OVER LG x die pUSLA 2 1 4 1 Potentiostatic Mode ined 2 1 4 2 Galvanostatic Mode 200 3 1 5 Polarity Convention 000 3 1 6 Inspecting Your New Instrument 00000 4 1 7 Maintenance Service and Suppor
11. ICT i C AIR INTAKE q e Y 3 4 OR EXHAUST x 2C 24 E lt y MAINTAIN 4 INCHES MINIMUM CLEARANCE 4 C 2 i BETWEENREAR DIK DIK gt AND OBSTACLES E aot Ed E x C gt lt jiet C A b y A v Fa N CAUTION ke 2 ELECTRICAL SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE ae poes DISCONNECT AC POWER INPUT REFER SERVICING TO QUALIFIED PERSONNEL Sa BEFORE REMOVING ANY COVER OR PANEL OPENING CASE VOIDS WARRANTY AUXILIARY C INTERFACE C U8 J c c3 c3 f es SELECTED VOLTAGE KI k C JO om amp M 50 60 Hz zs m0vac sugar SYNC A B c D DAC 7240 ADC OUTPUT INPUT NON SYNC ADC INPUTS Fig 4 PARSTAT 2273 Rear Panel 3 2 1 1 Connectors INPUT POWER Corcom Power Entry Module on lower left mates with the supplied power cable which depends on the country of destination that connects to the ac power supply The PARSTAT 2273 input voltage range is 100 120 V AC or 220 240 V AC 50 60 Hz 600 W maximum For more information on the Corcom module see Section 2 2 AUXILIARY INTERFACE This DB9 female connector provides several functions including the signals required to drive a Model 303A Static Mercury Drop Electrode If using a Model 303A you must connect the electrode to the AU
12. PARSTAT 2273 Potentiostat Galvanostat Hardware User s Manual Advanced Measurement Technology Inc a k a Princeton Applied Research a subsidiary of AMETEK Inc WARRANTY Princeton Applied Research warrants each instrument of its own manufacture to be free of defects in material and workmanship Obligations under this Warranty shall be limited to replacing repairing or giving credit for the purchase price at our option of any instrument returned shipment prepaid to our Service Department for that purpose within ONE year of delivery to the original purchaser provided prior authorization for such return has been given by an authorized representative of Princeton Applied Research This Warranty shall not apply to any instrument which our inspection shall disclose to our satisfaction to have become defective or unworkable due to abuse mishandling misuse accident alteration negligence improper installation or other causes beyond our control This Warranty shall not apply to any instrument or component not manufactured by Princeton Applied Research When products manufactured by others are included in Princeton Applied Research equipment the original manufacturer s warranty is extended to Princeton Applied Research customers Princeton Applied Research reserves the right to make changes in design at any time without incurring any obligation to install same on units previously purchased THERE ARE NO WARRANTIES THAT EXTEND BEYOND
13. STAT 2273 is powered on PARSTAT 2273 Hardware User s Manual 3 3 Connecting to the PC and Cell This section tells you how to connect the PARSTAT 2273 to the host PC and electrochemical cell and to other equipment you might wish to use with it WARNING For operator and equipment safety power to all instruments should be off when connecting or disconnecting cables 3 3 1 Connecting to the PC The PARSTAT 2273 is shipped with a standard USB cable Connect it between the rear panel USB connector and a USB port on the PC As noted above you can connect to and disconnect from the PC without shutting down or restarting Windows or Electrochemistry PowerSuite however see the note in Section 3 2 1 1 3 3 1 1 Installing the USB Driver The first time the PARSTAT 2273 is connected to the host PC and powered on Windows will display a Found New Hardware message then ask you to load the USB driver file ezusb sys To do this insert the CD ROM for your Electrochemistry PowerSuite module supplied with the instrument On the Windows Taskbar click on Start Run In the Run dialog click on Browse then go to the CD ROM Double click on the disk1 folder for any one of the Electrochemistry PowerSuite modules for instance PowerCORR Double click on the ezusb sys file then click on OK 3 3 2 Connecting the Cell To connect the cell cable part no 223622 to the PARSTAT 2273 1 Make sure the POWER switch is off 2 Grasp the connector
14. THE DESCRIPTION ON THE FACE HEREOF THIS WARRANTY IS IN LIEU OF AND EXCLUDES ANY AND ALL OTHER WARRANTIES OR REPRESENTATIONS EXPRESSED IMPLIED OR STATUTORY INCLUDING MERCHANTABILITY AND FITNESS AS WELL AS ANY AND ALL OTHER OBLIGATIONS OR LIABILITIES OF PRINCETON APPLIED RESEARCH INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR PRINCETON APPLIED RESEARCH ANY ADDITIONAL OBLIGATION OR LIABILITY NOT EXPRESSLY PROVIDED FOR HEREIN EXCEPT IN WRITING DULY EXECUTED BY AN OFFICER OF PRINCETON APPLIED RESEARCH SHOULD YOUR EQUIPMENT REQUIRE SERVICE A Contact the Customer Service Department 865 482 4411 or your local representative to discuss the problem In many cases it will be possible to expedite servicing by localizing the problem B If it is necessary to send any equipment back for service we need the following information 1 Model number and serial number 5 Your telephone number and extension 2 Your name instrument user 6 Symptoms in detail including control settings 3 Your address 7 Your purchase order number for repair charges does not apply to repairs in warranty 4 Address to which the instrument should be returned 8 Shipping instructions if you wish to authorize shipment by any method other than normal surface transportation C U S CUSTOMERS Ship the equipment being returned to Advanced Measurement Technology Inc PHONE 865 482 4
15. The 2273 connects to your PC or laptop via Universal Serial Bus USB and uses one of our Electrochemistry PowerSuite family of electrochemistry software modules there are no user controls on the instrument itself Calibration operation and experimental procedures are covered in the Electrochemistry PowerSuite HTML Help Manual available on the software s Help menu Major Features 2 Acurrent maximum 20 A boosted 100 V compliance 1 2 fA current resolution gt 10 input impedance typical lt 5 pF of capacitance typical 10 uHz to 1 MHz built in analyzer for impedance 1 1 Applications Research Electrochemistry From determining the kinetics of an electron transfer process to developing new and improved materials via unique electrodeposition or electrosynthesis techniques the PARSTAT 2273 was designed with the flexibility and capability required by today s electrochemical researcher Whether you are measuring a microelectrode rotating disk electrode mercury electrode or quartz crystal resonator the 2273 supports the wide array of electrodes used in a modern electrochemistry research lab Corrosion The 2273 is ideal for corrosion research Whether you are measuring rebar in concrete or titanium in Ringer s solution the 2273 was designed to address your application Our PowerCORR Corrosion Measurement Software and PowerSINE EIS package complement the 2273 s impressive specifications to create the ultimate too
16. Use EIS to examine the impedance of the PEM at different humidity levels perform I V curves on solid oxide fuel cells SOFCs or run CVs on direct methanol fuel cell DMFC assemblies The 2273 together with the entire Electrochemistry PowerSuite package has the potential to take your research to the next level Biomedical Applications The 2273 exceeds the requirements for potentiostats galvanostats as described in ASTM F2129 Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices For implant biocompatibility studies the most common methods involve DC corrosion techniques such as cyclic potentiodynamic polarization for the determination of the breakdown or critical pitting potential Ej the corrosion or open circuit potential E the repassivation or protection potential E corrosion current lor and corrosion rates based on Tafel analysis The 2273 and PowerCORR give you all of these tools 1 2 Booster Interface Using the 2273 with one of our current booster options provides you with a seamless interface for our Electrochemistry PowerSuite software When a booster option is connected to the 2273 the software autoscales the data The 2273 has three current booster options to choose from e 8A 2273 option for 8 A 50 V e 10A 2273 option for 10 A 20 V e 20A 2273 option for 20 A 20 V 1 3 Hardware and Software The host PC provi
17. XILIARY INTERFACE connecter via the Model 507 12 3 2 1 2 Interface AUXILIARY INTERFACE can also turn the Model 616 Rotating Disk Electrode on and off with the STIR signal issued within Electrochemistry PowerSuite See Section 4 4 for the pin assignments USB Attach the supplied USB cable part no 752860 to this connector and to the USB connector on the PC You can connect to and disconnect from the PC without shutting down or restarting Windows or Electrochemistry PowerSuite NOTE In Electrochemistry PowerSuite when you connect or power on the PARSTAT 2273 you must close the current experiment then use the software s Search for Instruments command or the PowerSTAT potentiostat control module to establish communications with the PARSTAT 2273 See the Electrochemistry PowerSuite HTML Help Manual SYNC ADC INPUT This BNC allows you to monitor an auxiliary signal in the 10 V range with 16 bit resolution This signal is monitored synchronously with the E and channels NON SYNC ADC INPUTS Four nonsynchronous ADC inputs are provided The input range is 10 V with an input impedance of 10 kQ These inputs allow you to monitor auxilliary signals with 12 bit resolution Input signals could include conditioned signals such as temperature pH pressure or humidity At this time the Electrochemistry PowerSuite software supports communication with these inputs only for EIS PowerSINE DAC OUTPUT Rear panel BNC delivers a
18. arch and file a claim with the carrier Save the shipping container for possible inspection by the carrier WARNING If your instrument has been damaged its protective grounding might not work Do not operate damaged equipment Tag it to indicate to a potential user that it is unsafe to operate 1 7 Maintenance Service and Support The PARSTAT 2273 has been designed for optimum reliability and requires no periodic maintenance There are no user serviceable parts in this instrument Breaking the seal by opening the cover will void your warranty Contact the factory service department or the affiliate in your area if your unit needs service see the Warranty on page ii for more information Remember that our worldwide staff continues to support you after you have purchased your instrument We provide top quality service applications support and a variety of helpful information in the form of application notes technical notes and training materials For more information visit our website at www princetonappliedresearch com 1 8 About This Manual Chapter 2 describes recommended safety precautions for operating this instrument including the provision of adequate ventilation It also tells how to deal with transients on the power line and discusses the unlikely possibility of the instrument causing radio frequency RF interference Chapter 3 shows you how to set up your hardware It describes the functions of the connectors and indi
19. c discharge problems can sometimes be avoided by judiciously selecting the floor covering in the work area The simplest approach to the problem is to discharge your body by touching a grounded metal object just before touching the instrument particularly when making connections to the cell External line transient filters can generally suppress transients that enter the instrument via the line cord A suitable transient suppressor is available from Princeton Applied Research Various kinds of power line conditioners are also commercially available Chapter 2 SAFETY AND COMPONENT PLACEMENT 10 PARSTAT 2273 Hardware User s Manual 3 INSTALLATION This chapter describes the PARSTAT 2273 connectors and indicators and shows you how to connect it to the host PC electrochemical cell and other equipment you might wish to use with it The pinouts for the AUXILIARY INTERFACE connector are listed in Section 4 4 3 1 Enabling the USB Port on Your PC Some PC manufacturers ship their PCs with the USB port disabled Check for this before trying to use the PARSTAT 2273 If the port is disabled follow the PC manufacturer s instructions for enabling it 3 2 Connectors and Indicators 3 2 1 Rear Panel Figure 4 shows the rear panel of the PARSTAT 2273 MODE POWER m 8 U O AMPLIFIER a ka BOOSTER INTERFACE BOOSTER MONITOR N LILILILI f ka E OUT MON NORMAL CAUTION DONOTBLOCK ORRESTR
20. cator lights and shows how to connect the PARSTAT 2273 to the host computer and test cell Chapter 4 gives the physical and electrical specifications of the PARSTAT 2273 including the AUXILIARY INTERFACE connector pinouts As noted above the PARSTAT 2273 is completely computer controlled operation and experimental procedures are covered in the Electrochemistry PowerSuite HTML Help Manual 4 PARSTAT 2273 Hardware User s Manual 2 SAFETY AND COMPONENT PLACEMENT This chapter tells you the safety precautions to use when operating the PARSTAT 2273 Please be sure to read them It also includes some suggestions on placement of your system components and information on possible RF interference and transient sensitivity 2 1 Power Cord For safe operation the PARSTAT 2273 must be electrically connected to earth ground through a suitable protective conductor This connection is made via the earth ground prong of the 2273 s power cord plug therefore the power cord plug must be inserted into a socket outlet provided with the required earth ground contact The protective action must not be defeated by the use of an extension cord without a protective conductor by use of an adapter that doesn t maintain earth ground continuity or by any other means Wherever possible the instrument is furnished with a power cord plug that is compatible with the type of power socket in use where the instrument will be operated If you have to provide a power
21. des memory data processing input output and interface capabilities The PARSTAT 2273 electronically controls the measurement under direction of the software and the parameter values you enter from the host computer The PARSTAT 2273 is fully compatible with our Electrochemistry PowerSuite family of electrochemistry research and development tools While the software operates under all 32 bit Microsoft Windows operating systems the PARSTAT 2273 requires a USB interface and runs only under Windows 98 SE 2000 and XP 1 4 Potentiostatic Circuitry The potentiostatic section of the PARSTAT 2273 circuitry includes e Two 16 bit digital to analog converters DACs for versatile waveform generation e Four 16 bit analog to digital converters ADCs to measure current potential SYNC ADC INPUT and the potential for current interrupt e onboard microprocessor to perform the experiment defined by the operating software e Onboard memory to store the programmed parameters and data point values The PARSTAT 2273 operates with Electrochemistry PowerSuite in either the potentiostatic or the galvanostatic mode The potentiostatic and galvanostatic modes are described below 1 4 1 Potentiostatic Mode In this mode the PARSTAT 2273 controls the potential at the working electrode with respect to the reference electrode see Fig 1 The counter electrode is driven to the potential required consistent with the 100 V compliance of the control ampli
22. ell Enabled This LED lights when the internal cell relay is closed The cell relay is controlled by the host PC Cell On This LED lights when the internal cell relay is closed The cell relay is controlled by the host PC Ovid Current Overload The Ovid LED lights if the working electrode current exceeds the full scale current range This does not mean that the cell control loop is out of control For example suppose the PARSTAT 2273 has been programmed to establish a potential of 40 752 V and that under the established conditions a cell current of 0 5 mA occurs If the current range is 2 uA 20 pA or 200 the current monitoring circuits will be driven to the limit and the Ovid indicator will light even though the cell is still controlled at 0 752 V E Ovid Voltage Overload Unlike the Ovid indicator a lighted E Ovid indicator always means that the cell control loop is out of control or the electrometer has exceeded the maximum range of 10 V That is the control amplifier has reached its maximum compliance voltage of 100 V and the potential of the working electrode with respect to the reference electrode is not as programmed This could result from a connection error open cell connection an electrode problem an unacceptably high solution resistance or an instrument problem Comm This indicator lights when the PARSTAT 2273 and the computer are communicating Power This indicator lights when the PAR
23. fier to establish the desired working electrode potential The range over which the working electrode potential can be controlled is 10 V Windows 95 does not support USB internally but some USB drivers have been made as additions to Windows 95 These USB drivers do not have complete support for the USB port and do not work with PARSTAT instruments 2 PARSTAT 2273 Hardware User s Manual IRUPT PS REF gt 0 3 S GROUND gt _ POSITIVE 1 Que uH FEEDBACK o5 m i j m POWER TE AMP CEL SWITCH CURRENT INTERRUPT ELECTROMETER E REPORT gt CURRENT RANGE o2 oe COUNTER L REFERENCE SENSE K WORKING REPORT gt VE CONVERTER AT8S8252 SERIAL gt 325 kB 24 MHz 0 Fig 1 Potentiostat Mode Block Diagram 1 4 2 Galvanostatic Mode In galvanostatic operation the PARSTAT 2273 controls the current between the counter and working electrodes at the specified fraction of the selected current range up to the maximum of 100 the current range see Fig 2 The counter electrode is driven to the potential required consistent with the 100 V compliance of the control amplifier to establish the desired cell current The reference electrode is not used in the control loop but is usually used to measure the potential at some
24. ight not work Do not operate damaged equipment Tag it to indicate to a potential user that it is unsafe to operate The PARSTAT 2273 s ground protection is likely to be impaired if for example the instrument Shows visible damage Fails to perform the intended measurement Has been subjected to prolonged storage under unfavorable conditions Has been subjected to severe transport stresses The instrument should not be used until its safety has been verified by qualified service personnel 2 4 Component Placement Before assembling the system give some thought to component placement You will of course need convenient access to the computer keyboard and if applicable the printer Depending on the application you might also need to connect and disconnect the cell leads regularly When you re satisfied that the system is ready to install connect the units according to the instructions in Chapter 3 NOTE The standard system does not include an electrochemical cell You must supply a suitable cell and electrodes 2 4 1 Ventilation The PARSTAT 2273 specifications apply at the nominal line voltage 10 and at a temperature of 25 C 77 F unless otherwise noted Ambient temperature must not exceed 50 C 122 F See Section 4 3 for more detailed environmental specifications To maintain a safe operating temperature allow some free space minimum 15 cm behind the PARSTAT 2273 for adequate air circulation 2 4 2 Rad
25. input fuse Fuse ratings 100 120 V AC 6 3 A 250 V T slow blow 5 x 20 mm 220 240 V AC 3 15 A 250 V T slow blow 5 x 20 mm 4 3 Standard Environmental Conditions Temperature 0 50 95 maximum relative humidity non condensing Altitude Up to 2 000 m This equipment is designed to meet or exceed the requirements of the following standards e LVD EN61010 1 2001 EN61326 1998 Emissions EN55011 1998 Group I Class B Immunity IEC 61000 4 2 1995 ESD IEC 61000 4 3 1996 EM Field IEC 61000 4 4 1995 Burst IEC 61000 4 5 1995 Surge IEC 61000 4 6 1996 Conducted RF 4 4 AUXILIARY INTERFACE Pinouts 18 Pin Signal Function 1 Ground 2 TRIG IN This signal is issued if the Ignore external WAIT line option has been selected on the Expert Options page in the New Experiment Wizard 3 DISPENSE When using the PARSTAT 2273 with a Model 303 or 303A Static Mercury Drop Electrode SMDE via a Model 507 Interface this signal causes the electrode to perform a DISLODGE DISPENSE operation on command from the host PC set on the Cell Definition page of the New Experiment Wizard 4 TRIG OUT A TTL trigger output is provided on this line if the Issue pulse out before starting option has been selected on the Expert Options page in the New Experiment Wizard 5 BIT 0 IN Not used PARSTAT 2273 Hardware User s Manual Pin Signal Function 6 Not used 7 BITOOUT Not used 8 PURGE When using a Model 303 or 30
26. io Frequency Interference In a typical application it is unlikely that the PARSTAT 2273 will act as a source of noticeable RF interference However when operated near particularly sensitive equipment interference from the PARSTAT 2273 could be a problem Following is a discussion of steps you can take to minimize that interference Interference below about 10 MHz is most likely to be caused by RF currents flowing in the input and output cables or in the power line cord If excessive noise pickup is present check that other power sources or computer cables including monitor cables are near the electrochemical cell or cell cable If this does not eliminate the problem try decoupling the power line with an external filter At frequencies below 100 kHz an external isolation transformer could be helpful Chapter 2 SAFETY AND COMPONENT PLACEMENT 7 WARNING To reduce the risk of potentially dangerous electrical shock only a qualified service technician should perform this work and then only with the instrument disconnected from all sources of power At frequencies above 10 MHz these measures might not suffice to prevent radiation from being a problem particularly at VHF frequencies Additional measures will then be required Shielding is generally effective A suitable shield can be constructed using metal foil wire screening or similar materials Once the instrument is completely surrounded by the shield taking care not to und
27. l for any corrosion lab Are you working with large electrodes or resistive media The 2273 s 100 V compliance voltage takes care of that Studying a new corrosion inhibitor or coating technology Femtoamp current resolutions and 10 Q input impedance make even the toughest EIS measurements seem routine Sensors For potentiometric sensors such as ion selective electrodes and coated wire electrodes and amperometric sensors gas sensors thin film microelectrodes and chemically modified electrodes the 2273 provides current sensitivities that can surpass the requirements of the most demanding measurement parameters with a pA current range and fA resolution High compliance voltage allows for the growth of thin film electrodes and nanodeposition Biosensor development and analysis relies on techniques that are contained within the PowerC V cyclic voltammetry PowerSTEP chronoamperomtry chronopotentiometry and PowerPULSE M electroanalytical software packages Fuel Cells and Batteries For many years Princeton Applied Research potentiostats galvanostats have been used in the development of new energy sources From the early stages of battery development to the charge discharge experiments on the final product the 2273 has the current measurement range to address the challenges posed in developing the next generation of batteries Fuel cells offer a cleaner energy source for the future and the 2273 helps bring that technology to market
28. on the cell cable by the grooved sleeve turn it so the red dot aligns with the red mark on the CELL connector and press it into place To disconnect the cell cable connector grasp the grooved sleeve and pull straight out 3 Assemble the electrochemical test cell and prepare it with the test solution 4 Connect the color coded leads on the cell cable to the electrodes in the test cell as described in the following steps 5 n both potentiostatic and galvanostatic operation connect the red lead to the counter electrode and the green and gray leads to the working electrode The reference electrode plugs directly into the pin jack white and the black clip is ground An accessory kit is provided to convert the pin plugs to alligator clips should you need them for your setup The polarity of the potential at the counter electrode will be opposite the applied potential This is necessary to establish the correct polarity relationship at the working electrode versus the reference electrode Use of the black ground lead depends on a number of factors In most cases it is not used although it is available if needed for a special purpose such as providing ground to a shield or screen surrounding the cell CAUTION Take care that the leads do not accidentally short together Because the black ground lead is often unused it tends to be overlooked Because of this an accidental short involving this lead is usually more of a problem than
29. one end at a time Rotate the drum until the desired line voltage setting ME shows in the door window and firmiv press the drum Fig 3 Setting the Line Voltage and back into the holder Replacing the Fuses NOTE The spindles on each side of the drum are octagonal not round This gives each of the 4 settings a definite detent To avoid eroding these detents always remove the drum before rotating it Close the module door You are now ready to reconnect the instrument to the ac power source 2 2 2 Replacing the Fuses For 100 or 120 V ac line voltage use a 6 3 A T slow blow fuse Littelfuse type 213 5 x 20 mm or equivalent For 220 or 240 V ac line voltage use a 3 15 A T slow blow fuse Littelfuse type 213 5 x 20 mm or equivalent CAUTION Do not use makeshift fuses or short circuit the fuse holders To replace a fuse 1 2 Disconnect the instrument from the ac power source Use a small flat blade screwdriver or similar tool to pop open the module door The line fuse is in a plastic fuseholder drawer marked with an arrow B Gently pull the fuseholder out remove the old fuse and press in the replacement Slide the fuseholder back into the module and close the module door You are now ready to reconnect the instrument to the ac power source PARSTAT 2273 Hardware User s Manual 2 3 Defects and Abnormal Stresses WARNING If your instrument has been damaged its protective grounding m
30. round to a shield screen surrounding the cell Chapter 3 INSTALLATION 13 14 3 2 2 2 3 2 2 3 DANGER Potentials as high as 100 V at currents as high as 2 A could be present at the counter electrode lead of the cell cable The CELL ON indicator should always be off unlit when making the cell connections as well as when the cable leads are being examined or disconnected Ext In 10 V analog input Potential applied is summed with that set within Electrochemistry PowerSuite Input impedance is 4 0 kQ E Monitor Front panel analog output of voltage readings Range 10 V 50 output impedance I Monitor Front panel analog output of current readings Range 10 V 50 output impedance 0 to 2 V corresponds to full scale current range Controls Power On off rocker switch Cell Enable This safety override must be enabled as indicated by the Cell Enabled LED before you can use an external cell it does not turn on the cell This does not affect the use of the internal dummy cell If you try to start an experiment without enabling the cell the Electro chemistry PowerSuite software will prompt you to do so NOTE The Cell Enable switch also acts as an emergency cell disconnect During an experiment if you press Cell Enable while the cell is on the cell will immediately be disconnected and the experimented halted The software will display an emergency cell disconnect warning Indicators C
31. s not yield to these measures 2 4 3 Transient Sensitivity Princeton Applied Research instruments are designed and constructed to ensure normal operation in the presence of moderate transient levels Although these provisions are sufficient for operation in most places where this equipment is used it is certainly possible for transient levels in particular environments to be so severe that they make reliable operation uncertain There are three general types of high level transients 1 Static Discharge Transients from this source generally affect input or output circuits Input circuits that include MOS field effect transistors to achieve a high input impedance are particularly susceptible to damage from this source Damage typically occurs when the charge built up on a user s body discharges into an input or output connector as a connection is being made Among the factors determining the tendency for charges to build are the kind of clothing fabrics worn shoe materials and the materials in the floor or floor covering 2 High Level Transients Generated Internal to the Place of Use Such transients almost always enter the instrument via the line cord Possible sources include heavy duty electric motors RF equipment lasers diathermy machines arc welders spark chambers and others 3 Lightning Transients caused by lightning almost always enter the instrument via the line cord PARSTAT 2273 Hardware User s Manual Stati
32. t 00 eee en 4 1 8 About This Manual L 4 2 SAFETY AND COMPONENT PLACEMENT 000 ern rna 5 2 1 POWER COM ala PE eae WP DIT Nd bbe Ka rr Ko FRA pa 5 2 2 Line Voltage and FUSING sensira a Rar na Ae wee Reda mac heer wach Oboes 5 2 2 1 Selecting the Line Voltage 0 teeta 5 2 2 2 Replacing the Fuses 00 000 6 2 3 Defects and Abnormal Stresses 000 eee 7 2 4 Component Placement 000 ccc ehm 7 24 VenllallOri eere i AM earth ee a wna hese 7 2 4 2 Radio Frequency Interference 7 243 Transient ba eat aw VE tee 8 8 JINSTAEEATJONI oce ette a A 11 3 1 Enabling the USB Port on Your PC L 11 3 2 Connectors and Indicators 0 00000 11 3 2 1 Rear Panel Re prae SR RAUS Sl ea ABER T aa See amen audere NR RAE Gta ead 11 93 2 1 1 GoOnneclorS ots A eere EE M GE E wu s a E 11 3 2 1 2 Booster nterface ope ERU IER deste ena ik dew ee ted 12 3 2 2 Front Panel 3 tench ew head we dues de kar Ge petto dog alata wie eve PEG 13 93 2 2 1 GONNECTOI SE x cu e uet acl v aes RR aa tea DER E e eU au T aga A ine 13 9 2 2 2 COMUOIS duo oic ette a a ete x ni Dot ante e ee a e o d 14 3 2 2 3 InIdICatOTS oae sa e en Bob accedi ouo eu at atte ities
33. uly restrict ventilation the only additional requirement is to install low pass filters where lines pass through the shield all openings through the shield should be as small as possible A capacitor between a line and the shield can function as a suitable low pass filter The leads of the capacitor should be as short as possible We suggest using coaxial feedthrough capacitors In the case of a signal lead it is essential that the capacitor s value be such as to attenuate the interference frequencies without unduly attenuating critical frequency components of the signal itself NOTE Keep the filter capacitor leads short Long leads establish sizable ground loops and could additionally act as radiating antennae Coaxial cables are a special case in that the cable shield acts as an extension of the enclosure shield This being the case the filter can be counted in a shielded box fitted with coaxial connectors without undue concern for keeping the box extremely close to the enclosure If more convenient to do so it can be located at some distance from the enclosure as long as the integrity of the coaxial shield is maintained The preceding techniques are extraordinary measures that should be required only in unusual cases If they are applied with care RF interference should be reduced to an acceptably low level in all but the most critical applications Contact the Customer Service Department for advice in the case of a problem that doe
Download Pdf Manuals
Related Search
Related Contents
Transparency database TISECURITY user manual 1 - Xerox Panasonic SC-AK300 - Diagramasde.com HQ HE27CLAS002 MSG-2050A ANTI-GRIPPANT A L`ALUMINIUM Journal des Notaires "Notaires 79" COMPACTplus / PROFIsafe Copyright © All rights reserved.
Failed to retrieve file