1. AC adapter Battery pack Model HEM 9ADAP Model HEM 9BAT Art no 4928653 2 Art no 4928652 4 Options Large size arm cuff Medium size arm cuff Small size adult arm cuff Model HEM 9CLC Model HEM 9CMC Model HEM 9CSC Art no 4928654 0 Art no 4928640 0 Art no 4928639 7 Applicable arm Applicable arm Applicable arm circumference circumference circumference 32 to 42 cm 22 to 32 cm 17 to 22 cm Stand exclusive Air tube 1 3 m for this unit Wall hanging kit Pole mounting kit Model HEM 9T1 3 Model HEM 9ST Model HEM 9WM Model HEM 9PM Art no 4928648 6 Art no 4928649 4 Art no 4928650 8 Art no 4928651 6 11 Do not apply the arm cuff during the intravenous injection or transfusion Intravenous injection or transfusion is impossible How to Apply the Arm Cuff AWarning Requests from OMRON genator S Do not use the unit to the patient using a pump oxy e Do not inflate the unit without applying the arm cuff 12 Do not use the damaged cuff Select the arm cuff according to the arm circumference of the patient Arm circumference Name of the arm cuff 17 22 cm Small size adult arm cuff option 22 32 cm Adult arm cuff 32 42 cm Large size adult arm cuff option e Be sure to use the arm cuff suitable for the size of the patient s arm If an arm cuff not suitable for the size of the arm is used blood pressure may not be mea
2. Material damage refers to a wide range of damage involving your house household goods domestic animals and pets Examples of signs The A icon indicates caution including warning and danger Matters involving actual caution are indi cated by text or pictures in or near A The left icon refers to caution for ignition The icon indicates prohibitions what you cannot do Matters involving actual prohibitions are indi cated by text or pictures in or near The left icon refers to prohibition to disassemble A The icon indicates something that is compulsory always follow Matters involving actual compulsory actions are indicated by text or pictures in or near The left icon refers to pulling the power source plug If any abnormal matter occurs during the measurement such as inflation does not stop remove the arm cuff or pull out the air tube from the main unit e You may suffer peripheral neuropathy Do not wrap the arm cuff over the arm to which intravenous injection or transfusion is being conducted e Intravenous injection or transfusion is impossible Do not use the unit in the place where inflammable gas such as highly inflammable anesthetic may be generated or in a high pressure oxygen room or an oxygen tent e It may cause ignition and explosion Do not touch the AC adapter with wet hands e You may suffer electric shock gt PO Notes on Safety When you are n
3. tion is applied or the patient moves his her body 2 When an error is generated or the measured Requests from OMRON value is doubtful An error may be displayed when an external vibra Q e Be sure that the patient should not touch the unit tion is applied or the patient moves his her body 3 Set the MODE Selector to 4 Set the P SET pressure set Be sure to monitor all the time that the unit and the patient An error may be generated in the measured value SINGLE ting Volume to AUTO or the or the blood pressure may not be able to measure are not abnormal for the patient having peripheral circulatory distur Do not use the unit in a vehicle bance or extreme hypotension An error may be generated in the measured value or the blood pressure may not be able to measure for the patient having short variation of blood pres sure such as arrhythmia target inflation value e When setting the P SET to AUTO turn the Volume coun terclockwise as far as it goes until you can hear the click sound When the systolic pressure is Do not use a portable phone near the unit S expected to exceed 220 mmHg e The unit may malfunction proper inflation may not be pos sible in AUTO setting Set the target inflation value to 30 to 40 mmHg higher than the expected systolic pressure List of Measurement Modes 6 Measured results are displayed 5 Push the START Button
4. AC adapter or loose electric outlet e You may suffer electric shock or there may be short circuit or fire ignition Do not damage the power cord of the AC adapter by placing heavy thing on it or pinching it or modify forcibly bend pull twist or bundle it e You may suffer electric shock or there may be electric leak and fire because of deteriorated insulation Requests from OMRON e Do not place or put anything on the unit e Do not apply strong shock to or drop the unit When you move the unit be sure to turn off the power and remove the connected AC adapter e When using this unit concurrently with other unit be sure to read the Instruction Manual of the other unit to be used concurrently and understand the warnings and cautions before use e Be sure to confirm that all cords and tubes are connected correctly and completely before use e Inspect the Buttons and so on to confirm that the unit operates normally before use e When using a battery pack be sure to confirm that the voltage is sufficient before use If you are not going to use the unit for a long period of time remove the battery pack Do not inflate the arm cuff without being wrapped over the arm e Do not use a damaged arm cuff Do not use the unit in a vehicle e Be sure to monitor all the time that the unit and the patient are not abnormal e Please keep the unit out of the reach of patient e Clean and store the unit and accessories after each us
5. and explosion ble gas such as highly inflammable anesthetic may be generated or in the high pressure oxygen Do not touch the AC adapter with wet hands e You may suffer electric shock Be sure to use the power supply of 230 VAC e It may cause fire or electric shock sprayed with water or medication e You may suffer electric shock Do not install or store the unit where it may be A Requests from OMRON e If this unit is used concurrently with other unit be sure to read the Instruction Manual of the other unit to be used concurrently and understand the warnings and cautions before use e Inspect the Buttons to confirm that the unit operates nor mally before use Connect the AC adapter to the DC Jack of the main unit 1 and the electric outlet 2 e When using an optional battery pack Model HEM 9CMC the AC adapter functions as the charger also 13 How to Measure Blood Pressure How to Measure Blood Pressure i snee mode AW arnin g 1 Paea am cuff over the 2 Push the ON OFF power Button to turn on the power If any abnormal matter occurs during the measure In the following case confirm the measure ment such as the inflation does not stop remove ment with the stethoscope the arm cuff or pull the air tube from the main unit 1 When an irregular pulse wave is displayed e You may suffer peripheral neuropathy An error may be displayed when an external vibra
6. in accordance to the circumference of the patient s arm wrap it correctly then measure again Is the level of the brachium to which the arm cuff is wrapped at the same level as the heart Keep the level of the brachium to which the arm cuff is wrapped at the same level as the heart then measure again Specifications Name Model Display Measurement Measurement Range Accuracy Inflation Deflation Air Release Pressure Detection Power supply Electric Shock Protection Method Operating Temperature and Humidity Weight of Main Unit External Dimensions Accessories Options Please understand that specifications may be changed without prior notice OMRON Digital Automatic Blood Pressure Monitor HEM 907 Digital display Oscillometric method Pressure 0 to 299 mmHg Pulse rate 30 to 199 beats min Pressure Within 3 mmHg Pulse rate Within 5 of reading Automatic inflation with pumping Automatic deflation by electromagnetic control valve Automatic rapid air release by electromagnetic control valve Electrostatic capacity semi conductor pressure sensor AC adapter 230 VAC 50 Hz 20 VA or battery pack 4 8 VDC 6 W Class II B type 10 to 40 C 30 to 85 RH Approximately 910 g 139 W x 203 H x 131 D mm Adult arm cuff with built in air bag AC adapter air tube 1 m Instruction Manual with guarantee card Large size adult arm cuff adult arm cuff small siz
7. to start the measurement Refer to Page e If the inflation is determined i insufficient the unit may start inflation again automatically e If you want to stop measure ment push the STOP Button Refer to Page The unit deflates fast To measure only once SINGLE Mode To measure three times or two times consecutively AVG Mode To measure by using a stetho scope Refer to Page 7 Push the ON OFF power Button to turn off the power MANU Mode To confirm the accuracy of pres sure display Refer to Page ESS 14 How to Measure Blood Pressure ave mode Wrap the arm cuff over the patient s arm Set the MODE Selector to AVG Push the START Button to start the measurement e Set the unit to the start time of the first measurement then the unit starts measurement auto matically e After displaying the results of first measurement the unit will measure blood pressure in the set number of times automati cally by taking an interval e For the setting of the number of measurements the waiting time before start of measurement and the interval time refer to Page 6 Push the ON OFF power Button to turn off the power Push the ON OFF power Button to turn on the power PET MODE a XO Jy Set the P SET pressure set ting Volume to AUTO or the target inflation value e When setting the P SET to AUTO turn the Volume coun terc
8. OMRON INSTRUCTION MANUAL OMRON Digital Automatic Blood Pressure Monitor Model HEM 907 Thank you very much for purchasing the OMRON Digital Automatic Blood Pressure Monitor Requests from OMRON to the operators and the persons responsible for maintenance Please read thoroughly the Notes on Safety of this Instruction Manual before using this unit so that you can use it safely and correctly after sufficient understanding After reading this Instruction Manual please keep it near the unit all the times for future reference The managerial responsibility of using and maintaining the medical electronic instrument must be borne by the users including hospi tals and clinics Do not let anyone use this unit other than the doctors or the legally qualified persons Furthermore only the skilled persons can use this unit A Good a y wp Table of Contents ExemptioNS essere prandia niatipun nana 2 Names and Functions of the Parts 3 Notes on Safety e cccccesseeseeseseeteeeeeseetens 7 Components of the Product 0006 11 OPON S siete 11 How to Apply the Arm Cuff eeeeeeeeeee 12 How to Use the Power Source AC Adapter cecceeeceseeeeeeeseeteeteeeeeeeees 13 How to Measure Blood Pressure 14 SINGLE Mode vevsisecss cist teeesceaeastesen ents 15 AVG ole ee 16 MANU Mode cccceeeseeeeseeeeeseeeeeees 17 CHECK Mode c
9. asurement e When the measurement does not end within the specified time after starting the measure ment When the pressure is applied more than 5 minutes Overpressure error e If the rubber tube connecting the arm cuff and the Er3 e The arm cuff pressure exceeded 299 mmHg main unit is bent stretch it then measure Insufficient inflation error If the measurement is made by setting P SET to Er4 e Blood pressure could not be measured due AUTO ask the patient not move his her arm or to insufficient inflation after the measurement body during the inflation ends e When setting the P SET to AUTO turn the Volume counterclockwise as far as it goes until you can hear the click sound e Set the P SET to 30 to 40 mmHg higher than the systolic pressure of the patient then measure Indeterminable blood pressure error If the arm cuff is wrapped loosely wrap it correctly Er5 e Blood pressure could not be measured even then measure when the arm cuff pressure reached the specified pressure Pulse wave small error e If the arm cuff is wrapped loosely wrap it correctly Er6 e Pulse wave was too small then measure Do not wrap the arm cuff over a thick cloth or by rolling up the jacket or shirt Measurement error e Check if the patient has an arrhythmia Er7 e Relationship between systolic and diastolic pressures was abnormal Ask the patient not to move his her arm or body during the measurement Pulse rate error Er8 e Pule rate did not st
10. ay within the range of 30 to 199 beats min Device error e Contact the dealer where you purchased the unit or Erg the nearest OMRON dealer e There is a problem with the main unit of the blood pressure monitor 21 22 Troubleshooting If a trouble occurs while using the unit please check the following Problem What to inspect How to correct The unit inflates to abnormal ly high low pressure Is the arm cuff wrapped correctly Is the patient moving his her arm or body during inflation Wrap the arm cuff correctly and measure again Ask the patient not to move his her arm or body during measurement and measure again Does this trouble occur with a specific patient For patients having arrhythmia the unit may not inflate properly Check the measurement by the stetho scope The unit cannot measure blood pressure The blood pressure values are extremely high low First of all check the patient s condition After checking the patient with the stetho scope as needed take a proper measure in accordance with the list of error codes Is the patient moving his her arm or body during measurement Ask the patient not to move his her arm or body during measurement and measure again Does the patient have an arrhythmia Check the patient with a stethoscope Is the size of the arm cuff and the wrap ping of arm cuff correct Select the arm cuff
11. cesceeesereeeeeeeeeeneeeees 18 Installation and Replacement of Battery Packie tect rnanan 19 How to Clean the Unit after Use 20 List of Error Codes sisscissccccesctceesces eects casscieee 21 Troubleshooting seereis 22 Specifications eeceeeeeseeeeeteeeeseeeeeneeteees 23 Exemptions OMRON will not bear any responsibilities on the following matters 1 When a problem or damage occurs caused by the maintenance and or repair con ducted by a person other than OMRON or the dealer specified by OMRON 2 The problem or damage of OMRON product caused by the product of other man ufacturer not delivered by OMRON 3 The problem and damage caused by the maintenance and or repair using the repair parts not specified by OMRON 4 The problem and damage caused by the results not observing the Notes on Safety or the operational method mentioned in this Instruction Manual 5 Under the circumstances not within the operating conditions of this unit including the power source or the setting environment mentioned in this Instruction Manual 6 The problem and damage caused by the result s of remodeling or improper repair of this product 7 The problem and damage caused by act of god such as fire earthquake flood or lightening 1 The contents of this Instruction Manual may be changed without prior notice 2 We have thoroughly reviewed the contents of this Instruction Manual However if an inadequate descri
12. concentration ozone l Disposal of this product and used batteries should be carried out in accordance with the national Wipe the blood pressure monitor with a soft cloth squeezed well after moistened with water diluted dis infectant alcohol or diluted detergent To disinfect wipe the unit with a soft cloth squeezed well after moistened with the following disinfectant Benzalkonium chloride 0 01 0 2 wv Chlorhexizin 0 05 0 5 w v Amphoteric surface active agent 0 01 0 2 wW When cleaning or disinfecting the unit do not wipe the AC adapter Then wipe the unit with a soft dry cloth regulations for the disposal of electronic products CN List of Error Codes Error code Cause How to correct Inflation error If the connector of rubber tube connecting the arm Er1 e When the pressure does not exceed 15 cuff and the main unit is loose connect them cor mmHg after operating a pump for 15 rectly then measure seconds from the start of inflation e When the inflation does not reach the set e If the rubber tube connecting the arm cuff and the pressure of the arm cuff within the specified main unit is bent stretch it then measure time after starting the inflation If the arm cuff is wrapped loosely wrap it correctly Deflation error then measure Er2 When the deflation speed is too fast during the measurement e When the deflation speed is too slow during the me
13. e Do not clean the unit with gasoline thinner or high concentration alcohol e Do not disinfect the unit by autoclave or gas sterilization EOG formaldehyde or high concentration ozone e Do not store the unit in the following places Under the direct sunshine Dusty or salty environment Places which slope vibrate and or are prone to shocks Storage of chemicals or where gas may be generated Under high temperature and high humidity 10 Notes on Safety Maintenance 1 Be sure to inspect the unit on regular basis Check accuracy on a 1 year interval 2 If the unit has not been used for a while be sure to confirm that the unit operates normally and safely before use Durability The durability of this unit is five years Arm cuff is a consumable Measures to take at the time of trouble or accident If a device error Er9 occurs take the following procedure promptly 1 Remove the arm cuff from the patient s arm 2 Turn off the power and pull the AC adapter from the electric outlet If an optional battery pack is used remove it also 3 Display Trouble on the unit so that it cannot be used 4 Contact the dealer where you purchased the unit or the nearest OMRON dealer Components of the Product Main unit Medium size arm cuff with built in air bag Instruction Manual Model HEM 9CMC with guarantee card Art no 4928640 0 Applicable arm circumference 22 to 32 cm Air tube 1 m
14. e adult arm cuff cuff cloth of each size air bag of each size air tube 1 3 m air tube 1 m battery pack stand exclusive for this unit wall hanging kit pole mounting kit K Type B This blood pressure monitor fulfils the requirements of the EC directive 93 42 EC directive 93 42 EEC Medical Device Directive It also conforms to the European standard EN 1060 Non invasive Sohygmomanometers Part 1 General Requirements an Part 3 Additional Requirements for Electromechanical Blood Pressure Measuring Systems EU Represantative OMRON Healthcare Europe B V Wegalaan 57 NL 2132 JD HOOFDDORP C 0197 23
15. e connector in the battery cover Replacement Remove the battery pack from the connector and replace with a new one 3 Install the battery cover and fasten it with screws Battery life e You can use the unit for approximately three hundred measurements eifa Cd mark appears frequently even after the battery is charged replace the battery e Approximate battery life is two years Charging time e After inserting the AC adapter the battery will start to charge automatically in approximately five seconds e While the battery is being charged a d __ mark turns on e The battery can be charged in approximately twelve hours Battery low e Even aftera a lt S M mark starts to flash you can use the battery for twenty to thirty measurements However it is um better to charge the battery as soon as possible wy A YY elfa Cd mark is displayed the battery is low Please charge the battery 19 20 How to Clean the Unit after Use Pull the AC adapter from the electric outlet when cleaning the unit e You may suffer electric shock Requests from OMRON After cleaning the unit dry it well then insert the AC adapter to the electric outlet e You may suffer electric shock Q Do not clean the unit with gasoline thinner or high concentration alcohol Do not disinfect the unit by autoclave or gas steril ization EOG formaldehyde or high
16. ement 3rd Third measurement Pulse rate Charging Displays gt when the battery pack is being charged External power source Displays AC when the unit is connected to the AC adapter Displays q d for the unusable level Names and Functions of the Parts Explanation of Functions 1 Pressure setting function Inflation can be set by AUTO automatic setting or the target value AUTO automatic setting In the SINGLE single measurement AVG average and MANU auscultation Modes the monitor estimates the systolic blood pressure value during inflation and automatically inflates to the proper value Target value setting The monitor inflates to the target value Pressure value is set to 30 to 40 mmHg above the expected systolic pressure 2 Non display function A function not to display the results of measured blood pressures However the pressure values during the measurement are displayed This function can be used when SINGLE single measurement or AVG average Mode is selected 3 Manual deflation control function A function to accelerate the deflation speed by pushing a DEFLATION Button during deflation This function can be used when MANU auscultation Mode is selected re Gi op Names and Functions of the Parts 4 Setting mode change function You can set the number of times to measure the waiting time until the start of measurement and the inter
17. flate the monitor to a certain value pressure to be checked 6 Compare the value displayed on this monitor and that on the mercury 7 Open the air release valve of rubber ball to deflate CHECK result 1 In the measuring rule the test tolerance of blood pressure monitor accuracy of pressure when shipped from the facto ry should not exceed 3 mmHg 2 If the CHECK result is 3 mmHg or above contact the dealer where you purchased this unit or the nearest OMRON dealer Installation and Replacement of Battery Pack Do not disassemble or modify the battery pack Do not throw the battery pack into fire or heat it object such as the wire Do not charge the battery pack by using equip If the fluid in the battery is stained on your skin S AN Caution Do not short the polarities of battery using metal ment other than this unit or cloth immediately wash off the fluid with If the fluid in the battery pack gets into your eye water wash the eye with sufficient water without rub S e You may suffer injury or battery fluid may leak bing the eye Then immediately consult the doc or battery may heat ignite fire or explode tor for treatment e You may suffer injury or battery fluid may leak or battery may heat ignite fire or explode 1 Remove the battery cover on the back of the main unit 2 Installation To install the battery pack connect the battery pack connector to th
18. lockwise as far as it goes until you can hear the click sound e When the systolic pressure is expected to exceed 220 mmHg proper inflation may not be pos sible in AUTO setting Set the target inflation value to 30 to 40 mmHg higher than the expected systolic pressure Measured results are displayed e After the measurement is com pleted average values are dis played e Each time a DEFLATION defla tion control Button is pushed the measurement results for each time are displayed To stop the measurement during the measurement Push the STOP Button To start the stopped measurement again Push the START Button Wrap the arm cuff over the patient s arm Push the ON OFF power Button to turn on the power Set the P SET pressure set ting Volume to AUTO or the target inflation value e When setting the P SET to AUTO turn the Volume coun terclockwise as far as it goes until you can hear the click sound e When the systolic pressure is expected to exceed 220 mmHg proper inflation may not be pos sible in AUTO setting Set the target inflation value to 30 to 40 mmHg higher than the expected systolic pressure Push the ON OFF power Button to turn off the power How to Measure Blood Pressure i mau mode Place the stethoscope on the patient s arm Set the MODE Selector to MANU Push the START Button to start the measurement In the AUTO setti
19. nerated in the measured value or the blood pressure may not be able to measure for the patient having short variation of blood pressure such as arrhythmia After cleaning the unit dry it well then insert the AC adapter to the electric outlet e You may suffer electric shock Insert the AC adapter to the electric outlet as far as it goes Wipe off the dust on the AC adapter e You may suffer electric shock or there may be short circuit or fire ignition If you find any trouble with this unit immediately stop using it turn off the power pull out the AC adapter from the electric outlet then contact the repair department e You may suffer electric shock or there may be short circuit or fire ignition e You may suffer electric shock Do not install or store the unit where it may be sprayed with water or medication A Do not disassemble or remodel the unit e You may suffer electric shock or there may be short circuit or fire ignition Do not use the unit to the patient using a pump oxygenator e The unit can not measure correctly The unit cannot measure when it cannot detect any beat Do not use the AC adapter and the battery pack not specified for this unit e It may cause fire or electric shock Do not use a portable phone near the unit e The unit may malfunction Do not install the parts and or instrument not specified for this unit e It may cause damage to the unit Do not use the damaged power cord or
20. ng the unit stops inflation at the pressure considered to be 30 to 40 mmHg above the expected sys tolic pressure then start defla tion e The unit can be re inflated only while the START Button is pushed e The pressure display is syn chronized with the pulse rate and renewed Each time the DEFLATION deflation control Button is pushed the unit deflates by 5 10 mmHg When you press the STOP Button the unit deflates fast and ends the operation 17 18 How to Measure Blood Pressure i check mode Display of pressure can be confirmed by the CHECK Mode yearly procedure What you need to prepare 1 Well adjusted reference pressure monitor including rubber ball 2 T shaped tube 3 two rubber tubes and 4 something in the cylindrical shape to wrap the arm cuff such as the tea container sturdy one that will not break or deform with pressure Measurement error may occur even with the mercury blood pressure monitor because of insufficient amount of mercury in the mercury dirty glass tube or clogged glass tube cap How to use the blood pressure monitor 1 Connect the mercury blood pressure monitor rubber ball and this unit with the T shaped tube as shown in the Figure 2 Push the ON OFF power Button to turn on the power 3 Set the MODE Selector to CHECK 4 Tightly wrap the arm cuff over a sturdy cylindrical object 5 Close the air release valve of rubber ball and in
21. ot going to use the unit for a long period of time be sure to remove the AC adapter from the electric outlet e You may suffer electric shock or electric leak or fire may arise because of deteriorated insulation Be sure to remove the AC adapter from the electric outlet when installing removing or cleaning the part e You may suffer electric shock or injure yourself Pull the AC adapter from the electric outlet when cleaning the unit e You may suffer electric shock Notes on Safety Be sure to use the power supply of 230 VAC e It may cause fire or electric shock Do not share an electric outlet with other unit or electric appliance e It may cause fire or electric leak Do not pull the power cord when pulling out the AC adapter from the electric outlet e The power cord will be disconnected or shorted and may cause fire or electric shock In the following case confirm the measurement with the stethoscope 1 When an irregular pulse wave is displayed An error may be displayed when an external vibration is applied or the patient moves his her body 2 When an error is generated or the measured value is doubtful An error may be displayed when an external vibration is applied or the patient moves his her body An error may be generated in the measured value or the blood pressure may not be able to measure for the patient having peripheral circulatory disturbance or extreme hypotension An error may be ge
22. ption or error is found please let us know 3 It is prohibited to copy a part of or the entire Instruction Manual without getting OMRON s permission Unless this Instruction Manual is used by an individual company it cannot be used without getting OMRON s permission from the standpoint of the Copyright Law Names and Functions of the Parts 6 ON OFF power 2 HIDE non display Button Button 7 START Button 8 DEFLATION deflation control Button 9 Arm Cuff Connector 4 P SET pressure setting Volume 10 STOP Button 5 MODE Selector Names and Functions of the Parts Ready to Measure Pulse level Number of a ms irregular pulse waves SYS READY TO Number of irregular pulse waves am am am N MEASUR The pulse wave having a difference of f more than 25 from the average Systolic blood vl gt a i interval of pulse waves is determined pressure g as irregular Number of irregular pulse on Sar waves are displayed up to three times ce Ae Example of display DIA l PULSE a a am i LEVEL No of arrhythmias a nnn p eee Diastolic blood a E i j i I ressure l p a ag a i l i I I l BATTERY CHARG I I l Pa EXTERNAL Battery level Displays iC for the usable level a V gt Displays a a m 4 A for the low level Contents when the AVG Mode is selected AVG Mean value ist First measurement 2nd Second measur
23. sured correctly Securely connect the air tube Cuff side e If you connect the attached 1m air tube the air tube can be used with the entire length of 1 2 m Air tube side Prepare the patient to be ready to wrap the arm cuff Wrap the arm cuff over the right upper arm s skin as a rule If the arm cuff is wrapped over a thick cloth or by rolling up the jacket or shirt blood pressure may not be measured correctly Place the right hand of the patient with the palm of hand facing upward 5 Place the arm cuff over the patient s arm by matching the mark indicat ing the artery position arr to the brachial artery v Wrap the arm cuff snugly using both hands and securely fasten it with the Velcro tape At this time the lower edge of the arm cuff must be placed 1 to 2 cm above the inner side of elbow joint e If the arm cuff is not wrapped snugly patient may feel numbness on his her arm or blood pressure may not be mea sured correctly e The arm cuff wrapped diagonally along the shape of the arm does not affect the measurement value How to Apply the Arm Cuff con 7 Adjust the level of the arm cuff to the level of the heart e Keep the level of the arm cuff at the same level as the heart during the mea surement How to use the Power Source AC adapter exclusive for this unit Do not use the unit in the place where inflamma room or the oxygen tent e It may cause ignition
24. val between measurements F1 F2 F3 Items to set Number of measurements Waiting time until the start of measurement Measurement interval time Procedure to change the set values 1 When the power is off press the ON OFF Button for more than three seconds while holding the START Button and change the mode to the Setting Change Mode 2 Press the START Button to select the item from F1 to F3 3 Press the DEFLATION Button to change the set values List of Functions for each Mode Set value 2 times 3 times 0 sec 3 min 5 min 10 min 5 sec 30 sec 1 min 2 min 3 min Measurement Mode Function Single measure ment SINGLE Average AVG Check CHECK Auscultation MANU Pressure setting function O O C Non display function O O Manual deflation control function O pean Setting mode change function Notes on Safety e The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening e The icons and meanings are as follow Warning sign Contents j Indicates matters in which death or sever bodily damage may arise as a result of incorrect A Warning handling c Fi Indicates matters in which bodily harm or material damage may arise as a result of incorrect A Caution handling

Download Pdf Manuals