1. Rinsing Disinfection Final Rinsing Inspection Packaging Sterilization Storage Operating mode Rinse the accessories manually with plenty of water clean manually the accessories with an adequate brush pre soaked in a clean pre disinfectant solution See point 2 Immerse the accessories in a disinfectant solution bactericidal virucidal fungicidal tuberculocidal and aldehyde free according to the manufacturer recommendations See point 2 After rinsing the accessories should be dried Inspect devices and sort out those with defects Pack the devices in Sterilization pouches Steam sterilization at 134 C 237 F for 18 min Keep devices in sterilization packaging in a dry and clean environment Warning the hook mechanism has to be activated during the cleaning process press the push button several times no visible impurities should be observed on the accessories Follow instructions and observe concentrations and time given by the manufacturer Dirty instruments must be cleaned and disinfected again Check the validity period of the pouch given by the manufacturer to determine the shelf life Use packaging which is resistant up to a temperature of 141 C 286 F and in accordance with EN ISO 11607 The clip must be sterilized according to the packaging labeling Use fractionated vacuum or gravity less preferred
2. autoclaved J Warranty Detect is warranted for 24 months from the date of purchase The accessories cables battery etc are warranted for 6 months from the date of purchase The warranty is valid for normal usage conditions Any modification or accidental damage will render the warranty void K Technical Specifications Detect electronic apex locator belongs to the following category of medical devices Internally powered equipment 2 4V NiMH rechargeable battery Type BF applied parts Continuous operation Not suitable for use in the presence of flammable anesthetic mixtures with air oxygen or nitrous oxide Environmental conditions during transportation temperature 20 C to 60 C 0 to 140 F relative humidity Ingress of liquids not protected 10 to 90 non condensing TECHNICAL SPECIFICATIONS Dimensions 130 x 80 x 63 mm Weight 360 gr Type of Screen Color Graphic TFT Screen Dimensions a Supply 2 4V NiMH rechargeable battery 120 V 50 60 Hz or 230V 50 60 Hz External Charger Output 6V DC External Charger Input L Standard Symbols On the device label appears standard symbols as follows Attention consult N Type BF applied part O Class Il Equipment accompanying documents Recycling PLEASE DO NOT THROW AWAY This product ma and all its components must be recycled through your supplier Direct Current Disinfection Cleaning amp Sterilization Procedure for Detec
3. autoclaves according to EN 13060 EN 285 Use validated sterilization procedure according to ISO 17665 1 Follow maintenance procedure of the autoclave device given by the manufacturer Use only the listed sterilization procedures Sterility cannot be guaranteed if packaging is open damaged or wet check the packaging before using the instruments Manufactured for DENTSPLY Maillefer DENTSPLY International Inc DENSPLY 608 Rolling Hills Drive Johnson City TN 37604 1 800 924 7393 1 800 924 7389 fax www maillefer dentsply com Ci CONSULT INSTRUCTIONS FOR USE For Dental Use Only Rx Only Manufactured Under U S Patent 6 425 875 2010 DENTSPLY International Inc DETECTDFUO5 10
4. MAILLEFER Detect APES LOCAS Table of Contents US Introduction Indications For Use Contraindications Warnings Precautions Adverse Reactions Step By Step Instructions A Contents Recharging the Battery Replacement of the Rechargeable Battery Getting Started Search for the Apex Sound Adjustment Demo Mode Automatic Shutdown Maintenance of Your Detect Apex Locator Guarantee Technical Specifications L Standard Symbols Disinfection Cleaning amp Sterilization FOR DENTAL USE ONLY 3 Warnings See Contraindications Y Introduction See above e Only use the original charger Congratulations on the purchase of Detect y g g 4 AAN ee The Detect device must be used with the manufacturer s original accessories only In order to prevent infectious agent transmission it is highly recommended to use a rubber dam system during the endodontic procedure To ensure that short circuits do not impair the measurements be particularly careful with patients fitted with metal crowns or bridges avoid any metallic contact with the file or the lip clip e High concentrations of sodium hypochlorite may result in a lower accuracy For working length determination we recommend to use sodium hypochlorite solution at maximum 3 concentration e Make sure that the canal is wet enough to ensure reliability of the measurement e Ensure that the file does not touch another instrument
5. crew Gnemeasircmenkeable two lip clips 1 Release the screw and remove the battery compartment cover two connection hooks two connection forks 2 Remove the battery and disconnect the battery cable from the jack connector one user manual 3 Insert the new battery cable into the jack connector 4 Insert the battery into the battery compartment B Recharging the Battery 5 Close the battery compartment and secure it with the screw The Detect is delivered with a rechargeable battery Warning Use only the original battery pack from your supplier On the Detect a screen indicator shows the level of the battery charge When this is flashing the battery requires recharging However it is still functional for several treatments before the battery shuts down Procedure for recharging the battery a 1 Disconnect the measurement cable p 2 Connect the charger cable to the Detect 3 Connect the charger to the mains Charging screen will appear during battery charging When the battery image on the screen stops blinking and turns green the charging is complete CHARGING SCREEN COLOR GUIDE RED LOW ORANGE MID GREEN FULL Duration of charging About 12 hours 24 hours after long periods without use Note Detect cannot be used while charging D Getting Started 1 Disconnect the charger from the device if connected 2 Connect the measurement cable and switch the device On after a short logo presentat
6. e Do not expose Detect to any liquid e Avoid excessive liquids inside the tooth cavity to prevent overflow and incorrect measurements e Detect must be stored in normal temperature lt 60 C and humidity conditions e Do not use in the presence of flammable products e Teeth with open apices will give imprecise results e f the bar graph suddenly makes a large movement in the upper part of the canal continue slightly towards the apex so the signal returns normal I Indications for Use e An apex locator may not be able to measure in all conditions In any case it is The Detect is an electronic device used for apex location determination and working length recommended to take an X Ray prior to use of the unit and compare the information determination This product must only be used in hospital environments clinics or dental given by both means offices by qualitied dental personnel e For your own safety please wear personal protective equipment gloves glasses mask A Contraindications 5 Adverse Reactions ee The Detect is not recommended for use in patients that have a pacemaker or other None known implanted electrical devices d 6 Step By Step Instructions A Content C Replacement of the rechargeable battery Check the contents of the equipment before use The battery compartment is located at the bottom of Detect and the cover is secured one Detect apex locator one charger by a s
7. he 1 On Off button for about 2 sec until the second beep sounds and Demo indication appears in the bottom left corner of the display 3 During Demo cycle device operating sequence is shown on the screen Press 1 button to pause the simulation press 1 button again to resume 4 When Demo cycle is completed it is repeated automatically until interrupted by the operator 5 To exit Demo mode press 1 button and hold it for about 2 sec until a beep sounds Note If measurement cable is connected to Detect during Demo cycle the device switches automatically to normal operation mode H Automatic Shutdown Detect automatically shuts down after 5 minutes without use It is advisable however to manually switch off equipment after measurement by simply pressing the key 1 On Off Maintenance of your Detect The device does not contain user serviceable parts The service and repair should be provided by factory trained service personnel only After each use all the objects that were in contact with infectious agents should be cleaned using towels impregnated with a disinfecting and detergent solution a bactericidal fungicidal and aldehyde free solution Use of chemical agents may cause damage to the equipment Reprocessing procedure the lip clip the hook and the fork must be sterilized between treatments by autoclaving at 134 C See after for detailed procedure The measuring cable cannot be
8. ion the main screen is displayed and the cursor on the tooth image will start blinking While turning the device On without the measurement cable the main screen will be displayed without cursor on the tooth image 3 Attach the lip clip to the patient 4 Insert the file into the canal to ensure precise measurements the file size should be adjusted to the canal diameter 5 Connect the hook to the file The cursor on the tooth will stop blinking accompanied by a double beep signal A blinking cursor and no sound signal indicate a faulty connection Check your connections clean your hook connection moisten the canal if necessary and start again No other adjustments are necessary before starting measurement Note Connection test feature is included in Detect in order to check the cables e Connect metal part of the connection hook to the lip clip e Connection test icon amp gt lt I should appear in the bottom left corner of the display indicating proper connection e f no icon appears the connection hook or the measurement cable should be replaced E Searching for the Apex 1 Coronal and Medial Zone Slowly introduce the file into the canal The cursor on the tooth icon indicates the progression of the file inside the canal Further progression of the file in the canal is shown both by the cursor on the tooth icon and by the numerical value on the graphical scale which does not re
9. present length in millimeters Detect emits audible information of file progression via a series of progressive rate beeps 2 Apical Zone The apical zone is divided into 10 segments graduated from 0 9 to 0 0 apex as visual information of file progression When the apex is reached the cursor shows APEX and a solid tone is emitted BEGINNING OF APICAL ZONE MIDDLE OF APICAL ZONE APICAL POSITION ja o 200 MM N pal Once apex is reached it is recommended to subtract 0 5 mm to determine the working length for shaping 3 Over Instrumentation A red segment and a warning signal indicate that the file has passed the apex The cursor on the tooth icon shows OVER a l mi r F Sound Adjustment Detect is equipped with a sonic indicator which enables monitoring of the progression of the file within the canal This function in conjunction with the display of progression enables working blind while still monitoring the progression of the file The volume can be adjusted to one of four levels mute low normal and high by successive presses on the 17 volume key G Demo Mode The built in Demo mode is available to become acquainted with the device and to demonstrate its operation 1 Disconnect the measuring cable or the charger from the device if connected and turn Off the device 2 To start Demo mode press and hold t
10. t Accessories Foreword The Lip clip must be cleaned disinfected and sterilized before each use to prevent any contamination according to ISO 17664 This concerns the first use as well as the subsequent uses General Recommendations e The user is responsible for the sterility of the product for the first cycle and each further usage as well as for the usage of damaged or dirty instruments e For your own safety please wear personal protective equipment gloves glasses e Use only disinfecting solution which is approved for their efficacy DGHM listing FDA approval PROCEDURE FOR LIP CLIP HOOK AND FORK Operation Operating mode Warning Pre Disinfection or Soak immediately just Follow instructions and observe X Decontamination after usage all instruments concentrations and immersion time in a disinfectant solution given by the manufacturer an excessive combined with proteolytic concentration may cause corrosion or enzyme if possible others defects on instruments The disinfectant solution should be aldehyde free to avoid blood impurities fixation Do not use disinfectant solution containing Phenol or any products which are not compatible with the instruments See general recommendation For visible impurities that are observed on instruments a pre cleaning is recommended by brushing them manually with soft material PROCEDURE FOR LIP CLIP HOOK AND FORK CONT Operation Rinsing Manual Cleaning