Home
LED WALL WASHER LIGHT User Manual
Contents
1. LR n Es As analogy 4 Method for setting master slave All slaves with 1 1 0 on master setting refer to DIAGRAM II 5 DMX 5 CHANNELS CH1 Dimmer CH2 Red CH3 Green CH4 Blue CH5 Strobe music activated KEY POINT Easy to operate no flicker while dimmer stable quality Applicable to photograph camera and TV station as well
2. LED WALL WASHER LIGHT User Manual CONTENTS 1 INSTRUCTION Unpacking Introduction AC Power Safety Instruction Cleaning 2 FEATURE 3 SETUP 3 Pin to 5 Pin Conversion Chart Setting up a DMX Serial Data Link Master Slave Fixture Linking 4 OPERATING INSTRUCTIONS Operating modes Product overview Program Mode amp Sound Mode Master Slave Operation Master Slave Connections and Settings DMX Mode 5 DMX CHANNEL SUMMARY LED WALL WASHER LIGHT Introduction Unpacking Thank you for purchasing our products Every unit has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are missing save the carton and all packing materials In the event a fixture must be returned to the factory It is important that the fixture be returned in the original factory box and packing Introduction The unit is a DMX intelligent LED par can This light can be used in a standalone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This light has four operating modes Sound Active mode stand alone mode Master Slave and DMX control mode AC Power This fixture has an auto switching power suppl
3. ich will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on Operating Modes You can use the unit in either a standalone mode or a master slave configuration there are 4 modes to choose from Program Mode Choose a static color color show color fade show or color cycle The speed of the show is adjustable You can also have the unit strobe in this mode Master Slave Mode Using the Master unit chooses your desired mode or program and connects the Slave unit or units All slaves will now follow the Master unit But only one master DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller While the function you want for example if DMX MODE the ADDR amp MODE can be adjusted You can press SETUP button to catch them if MODE it has 6 models press UP amp DOWN to locate it Program Mode amp Sound Mode In Program Mode you can pick your desired factory installed program static color color show color fade or color cycle You can apply a strobe effect to static colors and control the speed of the color shows color fade and color cycle 1 Plug the fixture in and press the MODE button till 01 static display you are now in program model Press UP and DOWN to find your des
4. ired effect 2 If you have selected a static color press SET UP button to enter into the flash rate F 000 100 press UP and DOWN to adjust and select your desired flash rate 3 When you have chosen a color show 02 17 press SET UP button the display will show S000 S100 Press UP and DOWN button to adjust and set the speed When the display shows F000 F100 your desired program is running in strobe effect 4 When the display shows Sound the unit is working in sound active mode and the sensitivity SENS 00 99 is adjustable Master Slave Operation This function will allows you to link units together to run in a Master Slave mode In Master Slave operation one unit will act as the controlling unit and the others will react to the controlling unit s built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR jean microphone cables to link your units together Remember that the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only N Using the Master unit choose your desired mode or program and connect the Slave unit or units Set the Slave u
5. nector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior Figure 1 COMMON DMX512 OUT DMX512 IN 3 PIN XLR DMX 3 PIN XLR 3 Hot 3 Hot Figure 3 XLR Pin Configuration Pin Ground Pin 2 Data Compliment negative Pin 3 Data True positive 3 Pin to 5 Pin Conversion Chart Note Ifyou use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter The chart below details a proper cable conversion 3 Pin to 5 Pin Conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not Used Do not use Not Used Do not use Setting up a DMX Serial Data Link Universal DMX Controller 1 Connect the male 3 pin connector side of the e of the controler 2 Connect the end of the cable coming from the er rud iERRRRPRIRRIASiGR to the input connector of the next fixture consis ix 3 Then proceed to connect from the output as s soon Master Slave Fixture Linking Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture wh
6. nit may require service please contact us Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days W Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew LED WALL WASHER LIGHT Features LED long Wall Washer Light Input voltage 90 245V AC 50 60Hz Fuse 3A The max power 30W Lamp 252pcs 10mm ultra bright LEDs 108 Red 72Green 72Blue Life Time gt 100 000 hours life Beam Angle 30 degree light angel Function color strobe color pulse color gradual color cycle color running music activated color selection and speed adjustable Advantage indoor LED color bar a superior linear large surface washer the beam angle can be adjustable to achieve the best lighting effects Control Standard DMX 512 5CHs master slave stand alone auto running Sound Activity Sound activity synchronization Size 65 87 1070mm N W 23kg GW 2 6KG Packaging 150 120 1050 6pcs CTN LED WALL WASHER LIGHT Set Up Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR con
7. nit s to the DMX address mode They will now follow the Master unit Uo DMX MODE Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller 2 To run your fixture in DMX mode plug in the fixture via the XLR connections to any standard DMX controller Press MODE button till DMX MODE display and press SET UP button to enter the DMX address and DMX mode selection and then press UP or DOWN buttons to adjust the DMX address and DMX mode The channels value refers to the following channel summary LED WALL WASHER LIGHT DMX Channels Summary 1 DIAGRAM I 1 ground 2 signal 3 signal 2 DIAGRAM II ON OFF FUNCTION 1 2 3 4 5 6 7 8 9 10 Half Red lighted 2 1 3 4 5 6 7 8 9 10 Half Green lighted 3 1 2 4 5 6 7 8 9 10 Half Blue lighted 1 4 2 3 5 6 7 8 9 10 Full Red lighted 2 4 1 3 5 6 7 8 9 10 Full Green lighted 3 4 1 2 5 6 7 8 9 10 Full Blue lighted 5 1 2 3 4 6 7 8 9 10 Music activated 6 1 2 3 4 5 7 8 9 10 Stand alone Speed adjustable 7 1 2 3 4 5 6 8 9 10 Gradual with 1 or 8 1 2 3 4 5 6 7 9 10 Strobe 2 on 3 DIAGRAM III ON OFF FUNCTION 1 10 2 3 4 5 6 7 8 9 Choose 1 light 1 5 10 X346 LEO cuins PALENIE 1 6 10 2 3 4 5 7 8 9 Jn du 1 5 6 10 2434189 ifs
8. w proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged e This unit is intended for indoor use only use of this product out doors void all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 3 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufacturer s warranty In the unlikely event your u
9. y that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 90V and 240V AC All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit Even if the rheostat or dimmer channel is used solely for a 0 100 switch Safety Instructions Please read these instructions carefully which includes important information about the installation usage and maintenance of this product To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required volt age for your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There is no user serviceable parts inside Never operate this unit when its cover is removed Never plug this unit in to a dimmer pack Always be sure to mount this unit in an area that will allo