User manual OMM-1000 v0.9 120518 - AV

image

Contents

1. Input 5 and 6 key buttons move down and up Decrease and increase the port number EDID Configure Entry EDID Configure _1 Entry 1 Press input 1 key button to enter the EDID Configure Mode EDID Configure Input 01 Default Default Mode 1 Y2 N3 lt lt 4 gt gt 5 v6 A Note The EDID configuration that is shown next to the input number on the LCD display is current EDID mode 2 Select an input port by pressing input 5 or 6 key button 3 Press input 3 or 4 key button to change EDID mode 3 1 If you select Default Mode default EDID will be restored for allocated inputs EDID Configure Input 01 Default Default Mode 1 Y2 N3 lt lt 4 gt gt 5 v6 A Press input 1 key button then the OMM 1000 will recover the Default EDID to allocated input as below EDID Configure EDID Copying EDID Reading 3 2 If you select Auto Mix Mode mixed EDID of all attached displays will be saved in allocated input 3 3 If you select Output Copy Mode OMM 1000 reads EDID from any target displays and copies it in allocated input Note There is Edit Data Mode but it is used to modify existing EDID to make new EDID working with specific systems It is not recommended for general user For further information please contact techsupp opticis com 3 3 10Baud Rate Press FUNCTION key button ten times It sets RS 232 Baud Rate OMM 1000 supports 9600 19200 38400 57600 115200bps Old ba
2. and TELNET control messages will be shown Type command inputs to control OMM 1000 Refer to Chap 5 2 2 RS 232 2 2 1 Launching HyperTerminal The OMM 1000 modular matrix provides RS 232 serial communication The simplest way to control OMM 1000 over RS 232 is using embedded software in Windows OS HyperTerminal To launch Hyper Terminal Explained here is based on Windows XP OS Hyper Terminal is not available on Win 7 Connect the PC to OMM 1000 over RS 232 cable Select Start gt Programs gt Accessories gt Communications gt HyperTerminal Enter a name and choose an icon in Connection Description window and click OK In Connect To window ignore the Country Area Code and Phone Number fields but select available COM port of PC to be connected to OMM 1000 then click OK In COM Properties window set the parameters as below Bits per second baud rate 115200 115200 is default baud rate of OMM 1000 Data bits 8 Parity None Stop bits 1 Flow control None Note Bit per second of Hyper Terminal should be set as same as baud rate of OMM 1000 Click OK to save the parameters Go Start gt Programs gt Accessories gt Communications gt HyperTerminal then new icon will be shown Then select it to launch Hyper Terminal Type command inputs to control OMM 1000 Refer to Chap 5 Chapter 3 Key button operation 3 1 LINK mode It configures input output connec
3. oo oe oo Es E CH1 cH2 cH cue Figure 1 2 Rear panel of OMM 1000 1 5 Installation 1 5 1 Initialization Connect the provided AC power cord to AC power inlet and turn on switch on the front panel Then OMM 1000 will start initialization process To turn it off completely pull out AC power cord switch on the front panel is rest switch OMM 1000 Starting will be shown on LCD display After 7 10 sec OMM 1000 Booting complete message and hardware and firmware version information will be shown Now OMM 1000 is ready to receive commands from user 1 5 2 Connection for remote control Connect the OMM 1000 to PC with the supplied RS 232 cable Connect the OMM 1000 to PC with LAN cable with RJ 45 connector NOTE Typically the IP address of PC connected to the network is configured by DHCP server But if the PC is connected directly to the OMM 1000 the network server will not able to assign the IP address In this case network information of PC should be set manually The default IP address of OMM 1000 is 192 168 1 117 Before connecting OMM 1000 to your network please verify the availability of IP address in your network The IP address can be reconfigured by key button PC program or command lines over RS 232 or TCP IP 1 6 EDID Configuration EDID Extended Display Identification Data is an information set that is provided by a display to describe its capabilities to a graphic source It enables
4. input output name Video generator and so on Then the Set Config window as below will open 18 I i x Channel Name Input Output cro recherche ma muchematz ouster onos recien Toumtchemans oos emeari ouuchemans enor nachamen namens ao retcharelio Outpichanel onia rocana E ona roncen oupuchame2 Quinn ormutchmas oia rocas Toumuchemane Os recia oumuchemans ans racer ommichemeie Save Connect Info RS232 COM Port COM3 Baudrate 115200 Ethernet IP 192 168 1 117 e fono Save r Video Generator Resolution 1600x1200 60Hz v Pattern Vertical Color Bar Stop Apply AN ARE Control Lock Mode Channel Input 02 Ka Web Conrol Unlock v Data Conrol rock y Apply R5232 Baudrate 19200 7 wy Key Conrol wy unlock v Network IP Address 192 268 1 7 Bort Pe Subnet mask 255 255 255 0 Gateway 192 68 10 10 acy Fig 4 2 Set Config window of OMM 1000 PC program 4 1 1 Connect Info Select the way of control method between RS 232 and Ethernet UDP by click the radio buttons In case of RS 232 control enter available COM port number of your PC and select baud rate The baud rate should be same as that OMM 1000 115200 is default number of OMM 1000 of OMM 1000 to start it In case of Ethernet enter IP address of OMM 1000 and port number 3000 is default port Click save button
5. 1 EA RS 232 cable Straight type 1 EA PC software CD 1 EA 1 3 Notice of safe usage We recommend you to read following warning precaution and information before start to operate the OMM 1000 modular matrix Use of the equipment in a manner not specified by the manufacturer may result in ire coverable damage Keep the unit away from liquid magnetic and combustible substances Do not place heavy weight on the unit Move away from noisy environment such as vibration or impact Do not install the unit vertically Do not disassemble the unit 1 4 Physical description The OMM 1000 modular matrix chassis is mountable on a 19 standard rack Key buttons LCD display and reset switch are placed on the front panel as shown in Figure 1 1 dpric s OMM 1000 16X16 Multi format Matrix Figure 1 1 Front panel of OMM 1000 All Input and output cards interface ports and power supplier are placed on the rear panel as below Input bay for 4 input cards left side Output bay for 4 output cards right side SERVICE RJ 11 receptacle for firmware upgrade RS 232 Serial communication port LAN RS 45 receptacle for TCP IP or UDP control REFERENCE OUTPUT for internal video source for easy installation MONITORING OUTPUT for internal output port to monitor input signal Power supplier Dual power is an option Hit os o ii ei CH2 cH3 a4 SOVI4EO Ho ode co HBO oo gt CH1 CH2 H3 ote SOVI4EO
6. Right side 1280x720p 60Hz 1 Large screen Top side 3 small screen Bottom side Table 6 10 Supporting resolutions and layouts of QDVI O The first numeric data in command line represents slot number of output bay of OMM 1000 where QDVI O is inserted Command Description and reply Sets output resolution of QDVI O at 1920x1080P In this case QUADRES 3_9 QDVI O is inserted in 3 slot of output bay Reply QUADRES 03_09 Sets layout of QDVI O as quad screen In this case QDVI O is QUADLAY 1_5 inserted in 1 slot of output bay Reply QUADLAY 01_05 Request current status of QDVI O If one QDVI O is inserted in 2 QUAD slot and output resolution is 1600x1200 60Hz with layout 6 Reply QUAD 01_00_00 02_05_06 03_00_00 04_00_00 Table 6 11 Multi viewer card setting command examples 32 4 5 9 Slot status request It requests current cards type in input and output bay E o e ter ow mucoa sovr oe CT Table 6 12 Card types and its data The first numeric data in reply represents the order row of slot and second and third data represents type of input and output cards Command Description and reply Requests current cards type in input and output bay OMM 1000 has 4 rows of input and output slots If the input output cards are configured as below 1 row Single DVI input card 1 Fiber DVI output card 2 row Single DVI input card Multi viewer card SLOT 3 row 1 F
7. and close Set Config window then click Connect button on PC program If the connection is properly made current status of OMM 1000 will be shown at the bottom side of PC program 4 1 2 Channel Name User can allocate specific names for all inputs and outputs to distinguish them On Fig 4 2 The name of Camera 1 was assigned for Input CHO5 and Wall display 3 for output CHO7 Click Save button to save it then these will be applied on the PC program as shown in Fig 4 1 4 1 3 Video Generator Select the resolution and pattern of video generator Click Apply button to save it 4 1 4 Control Lock Mode It locks and unlocks the controls such as Web Data control RS 232 TCP IP and UDP and key button input Click Apply button to save it 4 1 5 Network It changes network information of OMM 1000 Click Apply button to save it 4 2 EDID setup OMM 1000 offers 3 types of EDID setting for easy installation with various displays in the market To set the EDID option for each input port click Set EDID button then Setup EDID window as below will open Mode Triput Channel F Ain Detect F omatt F sesei Fig 4 3 Setup EDID window of OMM 1000 PC program 20 To set EDID information for each input select mode button and click input channel For each mode multi input channels can be allocated Default mode is default EDID from the factory By selecting it default EDID will be recovered for all
8. generator The cursor shows that it is selected and activated Input 1 and 2 key buttons move the menu Input 3 key button decreases the number Input 4 key button increases the number Video Generator Resol 01 800x600 Image 01 V Bar Stop OSD ON 1 Select the resolution pattern and OSD by pressing the key buttons as guided above 2 Press ENTER key button to complete the process Note OSD shows the resolution and pattern information on the top left of the display 3 3 8 Monitoring Output Press FUNCTION key button eight times t allocates input to Monitor Output port for monitoring uses The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Monitoring Output Old Input 01 New Input 01 1 Connect a display to the Monitoring Output port and any video sources to the DVI input ports on the real panel 2 Select an input port by pressing input 3 or 4 key button 3 Press ENTER key button to complete the process 3 3 9 EDID Configure Press FUNCTION key button nine times It sets EDID information in input port OMM 1000 supports three types of EDID setting Default Mode Auto Mix Mode and Output Copy Mode For more information refer to Chap 5 2 The cursor shows that it is selected and activated Input 1 and 2 key buttons select YES and NO Input 3 and 4 key buttons move left and right Change EDID mode
9. 68 001 001 3 3 2 Subnet Mask Press FUNCTION key button two times The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right Subnet Mask O 255 255 255 000 N 255 255 255 000 Modify the Subnet mask address to be used for your network Press ENTER key button to complete the process The default setting is 255 255 255 000 3 3 3 IP Address Press FUNCTION key button three times The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right O 192 168 001 117 N 192 168 001 117 Modify the IP address to be used for your network Press ENTER key button to complete the process The default setting is 192 168 001 117 3 3 4 MAC Address Press FUNCTION key button four times The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right MAC Address O 00 11 AA EE DD FF N 00 11 AA EE DD FF Modify the MAC address to be used for your network Press ENTER key button to complete the process 3 3 5 UDP Port Number Press FUNCTION key button five times lt makes number
10. Monitor output setting command examples 30 4 5 6 EDID control command It stores EDID information in input port of OMM 1000 It requests current EDID setting for all input ports Command Description and reply Default mode Saves default EDID in input ports 1 7 and 15 T Reply EDID 01DEF EDID DE1 7 15 EDID 07DEF 1 EDID 15DEF EDID AUTO2 8 9 Auto mix mode Analyzes all EDID information of connected displays to makes optimized EDID then save it in input ports 2 8 and 9 Reply EDID 02AUTO EDID 08AUTO EDID 09AUTO Output copy mode Copies EDID information of output 3 display and EDID 0UT3_5 stores it in input port 5 Reply EDID 030UT EDID Requests current EDID setting for all inputs Reply EDID 010UT 02AUTOO30UT 16EDF Table 6 8 Monitor output setting command examples 4 5 7 Baud rate setting for RS 232 It sets RS 232 baud rate OMM 1000 supports 9600 19200 38400 57600 115200bps It requests current RS 232 baud rate Command Description and reply RS232 115200 Sets RS 232 baud rate Reply RS232 115200BPS RS232 Requests current baud rate Reply RS232 115200BPS Table 6 9 Baud rate setting command examples 31 4 5 8 Multi viewer card QDVI O setting It sets output resolution and layout of QDVI O It requests current status of QDVI O MEA ee 1920x1200 60Hz 1 Large screen Left side 3 Small screen
11. Ri IE 17 3 3 12 Reset ModE icon EB ss le 17 Chapter 4 PC program operatio Meen a aaa A A aaa aaan aA as 18 4 1 B sieiselup 2 ran a a hee teat ee eat hee eat ea 18 4171 Connect Into 2 22 A Hide 19 41 2 Channel Names a A a a aa 20 4418 Video Generators a tenn A i eG teen eA eee 20 41 42 Control Lock Mode isi satan ici dada eed aces 20 41 5 Netw rkiana avin teh eA te Ae ieee tek et ate ee ben 20 4 2 EDID S tU Dentist ach od 20 4 3 Opera a PSERISLEFELTHEFSPRESERTETEVEHEREUESTLPERTERCHELFURRERTLETEFCHEREEEELTLRFESCHETBORESRTLKOL EPEREE 21 4 3 1 NS nn 22 4 3 2 lmputichannel Status ci dances dd 22 4 3 3 Output channel Status ursnuusnseennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen 23 4 3 42 MultEvieWwer se Si ee see ede eet ee ah ied eta neers eee 23 Chapter 5 Web control panel OperatiON oococonoccccnonociconanoccncnanannnn nano cnn EENE nn rra rca 26 Chapter 6 Command input operation oooccccncccinninnnnccnnnccnnnncnn narco nc corn cnn rara 27 6 1 Command input structure oooconocccnncccnnnccononanonona nono ccnnn cnn nora 27 6 2 Examples of command inputs raisen en EEE AEE AE cnc naar cnn AS 28 6 2 1 Link input and output esaa a non cnn nan nn nr anna rra 28 6 2 2 Input and output status ss naa s aE corn nn nn non cnn anna rn 28 6 2 3 Network setting iii taa io is ia nadan 29 6 2 4 Video generator setting usuernneeennnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
12. User s Manual Version 0 9 OMM 1000 Multi format matrix 16x16 DVI HDMI SDI Matrix router Chapter 1 Introduction and installation 2 220044440nnnnennnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnannenn nennen 4 1 1 SA A 4 1 2 Shipping OO at A AA ada 5 1 3 Notice Of SAO USAS ii aia 5 1 4 Physical ISS CAPO a ee eed 6 1 5 STAN AA ina d 7 TSTS A A 7 1 5 2 Connection for remote control nccccccnnnnicinnnnnnncccconcnnnccnnnncnrancn nara 7 1 6 EDID Configuration rirse raada a triada 7 Chapter 2 Control Sei De a E cnn nnnn cnc 9 2 1 TA e e rai 9 E AT A re 9 2 1 2 Launching Telnet Laia leal rise 9 2 2 A er 10 2 2 1 Launching HyperTerminal sss soir nor aa Or EE ARTEA nn nc nnnn nn nn nan SSE 10 Chapter 3 Key button operation u nnnnnensnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 11 3 1 LINK MOJE hanini teta 11 3 2 UNLINK mode u nn A N E a ini 11 3 3 FUNCTION Moden nn a Innen 11 3 3 41 Gateway Rn Bein IND HERE nie 12 3 3 2 Subnet MaSK inicia a Re da 12 3 3 3 AA er es Bis Eile 12 do MAG Address u sen a Rene Nik 13 3 3 5 UDE POE NUMOS orain d a tag 13 3 33 65 Multi ViewWer a HN Ei 14 3 3 7 Nideo Generatotia ct fata A ia staal diate aia iat ieee 14 3 3 8 Monitoring Outpute incn anes ah A 15 3 3 9 EDID Gontigure situa tant tte at a ie 15 3 331 0 BaudsRate yc sa tit HR Rein 16 TABLE OF CONTENTS 3 3 14 Gontrol E ck 2 2 222 ei
13. a graphic source to identify the connected display The information set includes manufacturer product type phosphor or filter type timings supported by the display display size luminance data and for digital displays only pixel mapping data Once the graphic source reads the information set usually during the booting process the EDID determines the optimal format for a connected display OMM1000 supports storing of EDID information to an EEPROM for each Input OMM1000 has three way EDID settings 1 Default Mode default EDID from the factory 2 Output Copy Mode read of EDID from any target display and copy in input port and the most advanced one is 3 Auto Mix Mode analyzing of all EDID from the attached displays and store optimized EDID in input port to avoid any compliance problems in the field Sources q Displays INPUT 1 16 OUTPUT 1 16 WRITE EDID A EEPROMi pre E DID EA gt rron INTERFACE CONTROL lt gt roms Read Write gi sg I EEPROM16 p Figure 1 3 Concept of EDID setting and working in OMM 1000 modular matrix As depicted in Figure 1 3 once EDID is configured each EDID is stored in EEPROM in Input ports As a result the video sources are able to read EDID from the EEPROM during booting process even though the OMM 1000 and connected displays are not powered on yet Chapter 2 Control setup The OMM 1000 modular matrix can be controlled in various ways such as comm
14. and input RS 232 TCP IP Web control panel TCP IP supplied PC program RS 232 UDP as well as key button on the front panel To do this PC should be configured properly 2 1 TCP IP 2 1 1 TCP IP setup of PC TCP IP the abbreviation of Transmission Control Protocol TCP and the Internet Protocol IP is commonly used protocol to control remote computers To control OMM 1000 over TCP IP set network properties of PC as below Explained here is based on Win 7 OS Open Control Panel Select Network Status in Network and Internet menu Select Adapter setting Select Local Area Connection and right click to open property Select Internet Protocol Version 4 TCP IPv4 Enter IP Subnet mask Gateway and DNS server address compatible with the current network setting of OMM 1000 Click OK to terminate IP setup session Note If the IP address of OMM 1000 is 192 168 001 117 the PC IP address should be chosen as 192 168 001 nnn where nnn can range from 000 to 255 except 117 2 1 2 Launching Telnet Telnet is a terminal program embedded in Window OS system to access remote computers using TCP IP protocol With the network setting of the PC as above launch Telnet as below Make sure PC and OMM 1000 are connected by Ethernet Click Start menu and select Run Type CMD to open command widow Type telnet 192 168 1 117 Type current IP address of OMM 1000 Press ENTER then Welcome to OMM 1000
15. ard SDVI 4EO 4 3 4 Multi viewer The most outstanding feature of OMM 1000 is embedded multi viewer card QDVI O Multi viewer card QDVI O can choose 4 inputs among 16 inputs of OMM 1000 and configure and output these input signals with 7 different layouts 1 input 2 input 3 input 1 gt layout 2 layout 3 layout 4 layout 1 input 2 input 3 input 4 input 5 layout 6 layout 7 layout Fig 4 6 Layouts of Multi viewer 1 layout Select 1 input of QDVI O and output it on a full screen 2 layout Select 2 input of QDVI O and output it on a full screen 23 3 layout Select 3 input of QDVI O and output it on a full screen 4 layout Select 4 input of QDVI O and output it on a full screen 5 layout Make quad view of 4 inputs same size 6 layout Set 1 input on the left side and other 3 on the right side 7 layout Set 1 input on the top side and other 3 on the bottom side QDVI O can be inserted one of output slots and it will be shown on PC program as in Fig 4 5 Out slot 4 Click OUT SLOT 4 bar to launch Setup Quad Multiviewer Card window as shown in Fig 4 7 Select output resolution of multi viewer card first Select output layout Setup Quad Mulivewer Card Shot 4 Quad Multtiviemer Card Maschen Fig 4 7 Multi viewer card setup Note 1 Changing the output resolution and layout of multi viewer card QDVI O can be done by PC program and com
16. des a user friendly graphic interface and easy access to control OMM 1000 ifthe PC is connected to Ethernet But the functions are a little bit limited comparing with other methods The OMM 1000 supports standard web browser but Microsoft Explorer is highly recommended to run OMM 100 stably Before running the web browser to control OMM 1000 please confirm that Network setting of OMM 1000 and Ethernet connection of the PC Refer to Chap 2 and Chap 3 Launch the web browser and enter the IP address of current OMM 1000 into the URL address line For example ifthe IP address of OMM 1000 is set as 192 168 001 117 juttype 192 168 1 117 OMM 1000 Matrix Web Control CH0 CH 04 CH 01 CH 02 CH 03 CH 04 CH 07 CH 08 CH 10 CH 11 CH 12 CH 13 CH 15 CH 16 CH 06 CH 06 CH 07 CH 08 CH 09 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 Fig 5 1 Web control panel Fig 5 1 shows structure of Web control panel It controls input output connection and vide generator and informs simple input output status Please remind that after new input output connection user has to click LINK button and SEND button for new generator setting 26 Chapter 6 Command input operation The OMM 1000 modular matrix could be operated with various interfaces such as key button inputs command input through RS 232 and TCP IP Web control through TCP IP and PC program through RS 232 and UDP All functions are executed on a basis of a serial com
17. iber DVI input card Single DVI output card 4 row 1 Fiber DVI input card NO output card Reply SLOT 01_02_19 SLOT 02_02_21 SLOT 03_18_03 SLOT 04_18_00 Table 6 13 Slot status request command example 4 5 10Control lock command It locks and unlocks the controls such as Web RS 232 TCP IP and UDP It request open status of controls 33 Web control lock WUL Web control unlock Data control UDP TCP IP RS 232 lock DUL Data control UDP TCP IP RS 232 unlock Key control lock KUL Key control unlock Table 6 14 Locking type and its ASCII data Command Description and reply Locks data control POGRADE Reply LOCK DL Request current status of control method LOCK Reply LOCK WUL DUL KUL Table 6 15 Control lock command examples 34 pTicis Opticis Locations Opticis Co Ltd 907 Byucksan Technopia 434 6 Sangdaewon Dong Chungwon Ku Sungnam City Kyungki Do 462 120 South Korea Tel 82 81 737 8033 Fax 82 31 737 8079 For order support please contact your Distributor or Reseller For technical support visit Opticis web site www opticis com or contact techsupp opticis com 35
18. ion 1600x1200 60Hz IN SLOT 3 Single DVI Input E Pattern 09 InputChannel09 Lo InputChannel11 12 InputChannel12 Vertical Color Bar Stop USER Signal OFF 1600x1200p USER Signal OFF USER Signal OFF Monitoring Port IN ar 4 Single DVI Input 13 InputChannel1 InputChanneli4 Channel Input 02 USER Signal OFF Bd user Signal OFF Signal OFF N user Signal OFF Control Lock Mode OUT SLOT 1 1fiber Output loz Data Control Unlock Notie unk Key Control Unlock our SLOT 2 Single DVI Output OutputChannel05 OutputChannel06 Video wall 3 OutputChannel08 05 No Link 06 No Link 07 Camera 1 08 No Link RS232 amp Ethernet sane SLOT 3 Single DVI Output Sn OutputChan OutputChan RS232 Baudrate 19200 Bps 09 u nelt1 neli2 1P 192 168 001 117 Port 3000 j No Link No Link No Link Gateway 192 168 001 001 Subnet Mask 255 255 255 000 OUT SLOT 4 Quad Multi Viewer MAC Address 00 11 AA EE DD FF OutputChanneli3 OutputChannel14 OutputChannel16 13 14 16 No Link No Link No Link 2012 05 10 14 55 44 lt Recv uart_ent 71 2012 05 10 14 55 44 lt Recv OUT 14 Plugged 2012 05 10 14 55 44 gt Data OUT 151 2012 05 10 1 44 lt Recvl uart_cnt 71 2012 05 10 14 55 44 lt Recv OUT 15 Plugged 2012 05 10 14 55 44 gt Data OUT 16 2012 05 10 14 55 44 lt Recv uart_ent 71 2012 05 10 14 55 44 lt Recv OUT 16 Pluaged Fig 4 1 PC program of OMM 1000 4 1 Basic setup Click Set Config button to set the communication method
19. iple command inputs require executing multiple strings having each command per a string User can use capital letters and small letters for commands but cannot mix it like Link it must be corrected as link or LINK After all input commands OMM 1000 sends back replies to conform the execution of commands Input and output port number range from 1 to 16 and prefix 0 can be used such as 001 and 010 but in the replies after the command inputs the digits of port number are two such as 01 and 10 4 5 Examples of command inputs 4 5 1 Link input and output It makes single or multi connections of inputs and outputs It makes disconnection of all inputs when used with 0 t requests inputs and outputs status of OMM 1000 Command Description and reply Makes input 1 connected to output 10 Reply LINK 01110 Makes input 1 connected to output 3 and 4 to 7 Reply LINK 01 03 04 07 Makes input 5 connected to all outputs LINK 01110 LINK 1403 04 7 LINK 05 Reply LINK 05 i Makes all connections disconnected LINK 00 Reply LINK 00 anei Makes output 6 disconnected LINK 00 06 Reply LINK 00 06 Linke Requests current inputs and outputs connections status Reply LINK 01101 02 04 161131 Table 6 2 Link command examples 4 5 2 Input and output status It requests input signal status If the input is connected it
20. mand input but the graphic interfaces on the Web or the PC program make more efficient way to operate the OMM 1000 modular matrix Command input operation is accomplished through RS 232 or TCP IP For setting procedures for those protocols please refer to Chap 2 and Chap 3 4 4 Command input structure The command inputs are composed of a string of ASCII codes and its basic structure is Command Delimiter Data Delimiter or or _ Data End Table 6 1 shows all commands and its brief descriptions Command Description LINK Input and Output connection IN Input signal status request OUT Output signal status request NET Network information request NETGW Gateway address setting NETSN Subnet mask address setting NETIP IP address setting NETPA MAC address setting NETPT UDP port number setting VID Video generator status request VIDRES Video generator resolution setting VIDIMG Video generator pattern setting MON Monitoring port setting and status request EDID EDID mode setting EDIT Edited EDID transferring RS232 RS 232 Baud rate setting QUAD Quad viewer card status request QUADRES Quad viewer card output resolution setting QUADLAY Quad viewer card layout setting SLOT Input output slot status request LOCK Lock Unlock the control type Table 6 1 Commands set 27 The command input allows executing only one command Mult
21. mand input and key button operation 2 To change position of window in layout 5 6 and 7 user must change the order of input to QDVI O For example If the QDVI O is in output slot 2 to change window position of layout 5 as shown in Fig 4 8 user must change input output connection 24 Change Input output connection of OMM 1000 Fig 4 8 Changing widow position of layout In Fig 4 8 Video source A is output 5 of OMM 1000 and it is also the 1 input to QDVI O and source C is output 7 of OMM 1000 and the 3 input of QDVI O To change A and C user makes source A be connected to output 7 of OMM 1000 It will be the 3rd input of QDVI O then source A will be shown on the bottom left side of layout 5 As the same method if user allocate source C to output 5 of OMM 1000 it will be shown on the top left side 3 Scale down error will happen when the number of scale down vertical pixels are less than 1 5 Progressive input case or 1 4 Interlaced input case of original input vertical pixels For example in case of layout 6 if you use input resolution 1280x1024 and set the output resolution of QDVI O at 800x600 the number of vertical pixels of 1 2 and 3 inputs will be fitted into one third of output vertical pixels 600 In this case there would be an error because the number of scale down vertical pixels 200 600 3 is less than 204 8 1024 5 25 Chapter 5 Web control panel operation The Web control panel operation provi
22. nnnnnennnnnnennnnnnnennn nn 29 6 2 5 Monitor output port setting erraria ia oireeton E ArenA EEIE UREE nn 30 6 26 EDID control command erneeennnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnennn nn ennnnnnnennn nn 31 6 2 7 Baud rate setting for RS 232 nesnsensseenssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nen 31 6 2 8 Multi viewer card QDVI O setting 0usnnersnsennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen 32 0 29 Slot status regust neie ae A ae i 33 6 2 10 Control lock command e nn een aia idas 33 Chapter 1 Introduction and installation The OMM 1000 modular matrix enables to switch up to 16 different DVI HDMI or SDI sources to 16 different digital displays It can be configured using 4 input and output cards and each card has 4 ports of input and output Any input source whether it is a HD DVD player Blue Ray player or a computer with high resolution graphics can be routed to DVI and HDMI output digital display Note SDI is not a licensed HDCP interface and if the content received from HDMI is protected by HDCP there should be no output from the SDI slot 1 1 Key features Up to 16 DVI HDMI and SDI inputs and outputs can be configured Each card has 4 input or 4 output ports and 4 cards can be fitted into input and output bays Has Electrical DVI HDMI and SDI and Optical DVI input and output cards Any input formats can be converted to DVI HDMI and SDI B
23. ocated input channels Auto Mix mode is the most advanced one it analyzes all EDID of attached displays at the output ports of OMM 1000 and get optimized EDID By selecting it user can avoid any compliance problems in the field Output Copy mode is most popular one lt reads EDID from any target displays and copies it in input port Select output channel first and click input channels And click Apply button to save it There is User s Edit mode but it is used to modify existing EDID to make new EDID working with specific systems It is not recommended for general user For further information please contact techsupp opticis com 4 3 Operation And all of setting parameters will be shown on the right side of PC program as Fig 4 3 After clicking Connect button Refer to Chap 4 1 1 OMM 1000 is ready to get the command from user Connection Info Ethernet IP 192 168 1 117 Port 3000 Video Generator Resolution 1600x1200 60Hz Pattern Vertical Color Bar Stop Monitoring Port Channel Input 02 Control Lock Mode Web Control Unlock Data Control Unlock Key Control Unlock RS232 amp Ethernet RS232 Baudrate 19200 Bps IP 192 168 001 117 Port 3000 Gateway 192 168 001 001 Subnet Mask 255 255 255 000 MAC Address 00 11 AA EE DD FF Fig 4 4 Setting parameters of OMM 1000 21 The right side of PC program shows various connection status such as input output connections Input signal res
24. olution and status EDID setting for each input and Input output card information and used to make new input output connections too IN or 1 1Fiber Input InputChannel01 i i AS F Signal OFF Signal OFF Signal OFF Signal OFF IN SLOT 2 Single DVI Input umso ee AA 05 OUT 1920x1080p Signal OFF Signal OFF Signal OFF IN SLOT 3 Single DVI Input 7 Sinal generator InputChanmeli1 InputChannel12 10 DEF 1600x1200p 1 1 DEF Signal OFF 1 2 DEF Signal OFF IN SLOT 4 Single DVI Input gt InputChannel13 ERES ARA Es F Signal OFF Signal OFF Signal OFF Signal OFF OUT SLOT 1 1Fiber Output OutputChannel01 OutputChannel02 OutputChannel03 OutputChannel04 01 No Link 02 No Link 03 No Link 04 No Link ans SLOT 2 Single DVI Output ie OutputChannel06 Video wall 3 Camera 1 Camera 1 our SLOT 3 Single DVI Output OutputChannel09 OutputChanneli0 OutputChannelii OutputChanneli2 09 No Link 10 No Link No Link No Link OUT SLOT 4_ Quad Multi Viewer OutputChannel14 OutputChannel15 OutputChannel16 No Link 15 No Link 16 No Link Fig 4 5 Input and output status of OMM 1000 4 3 1 Input output connection Click one of input channels and click any of output channels If you click input CHO5 Camera 1 and click output CHO5 CHO6 CHO7 and CHO6 input signal 05 will be connected to output monitor 05 06 07 and 08 as shown in Fig 4 5 To connect one input to all output click All Link button and click desired input Then all of outp
25. rator It requests current video generator setting Table 6 5 describes the resolutions and patterns OMM 1000 supports By command input operation user can change these to be used with on site source for easy installation 800x600 60Hz Vertical Color Bar 2 1024x768 60Hz Vertical Color Bar scroll Interval 0 5sec 29 Vertical Color Bar scroll Interval 1 0sec Horizontal Color Bar Horizontal Color Bar scroll Interval 0 5sec Horizontal Color Bar scroll Interval 1 0sec Full White Full Yellow 1920x1080p 60Hz Full Cyan Full Green Full Magenta Full Red Full Blue Full Gray Table 6 5 Video generator resolutions and patterns Command Description and reply Sets video generator resolution by data 4 PRES Reply VIDRES 1280x1024 60HZ VIDIMG 3 Sets video generator pattern by data 3 Po Reply VIDIMG VCOLORBAR10SMOVE Requests current video generator resolution and pattern VID Reply VID 04_03 it means data 4 resolution and data 3 pattern Table 6 6 Video generator command examples 4 5 5 Monitor output port setting t makes input to connected to monitor output port It requests current input port that connected to monitor output port Command Description and reply Makes input 13 connected to monitor output ports MONA Reply MON 13 MON Requests current input port that connected to monitor output port oe Reply MON 13 Table 6 7
26. replies input resolution but if it is not connected it returns Signal Off It requests output status whether it is connected to display or not Command Description and reply Requests input 5 status Reply IN 05 1920x1200p or IN 05 Signal Off IN 05 28 OUTPUT 12 Requests output 12 status Reply OUT 12 Un Plugged or OUT 12 Plugged Table 6 3 Input and output status command examples 4 5 3 Network setting It sets IP Gateway Subnet mask MAC address and UDP port number It requests current network setting Command Description and reply NETGW 192 168 1 1 Sets Gateway address each data ranges from 000 to 255 Reply NETGW 192 168 001 001 NETIP 192 168 1 118 Sets IP address each data ranges from 000 to 255 Reply NETGW 192 168 001 118 NETSN 255 255 255 0 Sets Subnet mask address each data ranges from 000 to 255 Reply NETSN 255 255 255 000 NETPA AA BB CC DD EE FF Sets MAC address each data ranges from O0 to FF Reply NETPA AA BB CC DD EE FF Sets UDP port number data ranges from 0 to 65535 NEE S00 NETPT 3000 Requests current network setting Reply NETGW 192 168 001 001 NET NETIP 192 168 001 118 NETSN 255 255 255 000 NETPA AA BB CC DD EE FF NETPT 3000 Table 6 4 Network setting command examples 4 5 4 Video generator setting It changes resolution and pattern of video gene
27. setting data range from O to 65535 The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right Port Number Old data 03000 New data 03000 Modify the UDP port number to be used for your network Press ENTER key button to complete the process The default UDP port number is 03000 Note Port number setting in this section is used for UDP with supplied PC program not TCP IP with web browser or Telnet For TCP IP port number 23 is fixed value 3 3 6 Multi Viewer Press FUNCTION key button six times Multi viewer card QDVI O can choose 4 inputs among 16 inputs of OMM 1000 and configure and output these input signals with 7 different layouts For more details refer to chap 4 3 4 The cursor shows that it is selected and activated Input 1 and 2 key buttons move the menu Input 3 key button decreases the number Input 4 key button increases the number Multi Viewer SLOT No 01 Resol 01 800x600 Layer Layer 01 1 Select the SLOT No by pressing input 3 or 4 key button and select slot number where QDVI O is inserted by pressing input 1 or 2 key button 2 Select the output resolution 3 Select Layout 4 Press ENTER key button to complete the process 3 3 7 Video Generator Press FUNCTION key button seven times It changes resolution and pattern of video
28. tions for cross switching Press LINK key button _ 2 Press an input key button LCD will display current connected output 3 Press single or multiple output key buttons to select desired outputs 4 Outputs can be deselected by pressing the each output key button again 5 Press ENTER key button to save the configuration 6 To configure next Input output connection repeat steps 1 to 5 3 2 UNLINK mode It unlinks input output connection Press SHIFT key button 2 Press LINK key button 3 Press the input key button to be disconnected 4 Press ENTER key button 3 3 FUNCTION mode t configures basic setting of OMM 1000 to be controlled by command input and PC program Press FUNCTION to see features FUNCTION key button will cycle the following features repeatedly Gateway Subnet Mask IP Address Mac Address UDP Port Number Multi viewer It is activated when QDVI O is in output bay Video Generator Monitoring Output EDID Configure Baud Rate Control Lock Reset Mode 3 3 1 Gateway Press FUNCTION key button once The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right O 192 168 001 001 N 192 168 001 001 Modify the Gate way address to be used for your network Press ENTER key button to complete the process The default setting is 192 1
29. ud 115200 New baud 115200 Input 3 key button decreases the number Input 4 key button increases the number Press ENTER key button to complete the process The default setting is 115200 3 3 11Control Lock Press FUNCTION key button eleven times It locks and unlocks the controls such as Web RS 232 TCP IP UDP and key Button Control Lock Web Lock UnLock Data Lock UnLock Key Lock UnLock Input 1 and 2 key buttons move the cursor up and down Input 3 key button moves Lock Input 4 key button moves UnLock Press ENTER key button to complete the process 3 3 12Reset Mode Press FUNCTION key button twelve times It resets OMM 1000 It starts rebooting and restores all default setting Input 1 and 2 key buttons select YES and NO Press ENTER key button to complete the process Chapter 4 PC program operation The PC program and provides a user friendly graphic interface alternative to key button input and command input operation Copy OMM ver1 x exe file in any directories in your PC and double click it to run Then initial window of PC program for OMM 1000 as below will open OMM1000Ver0 93 IN SLOT 1 1Fiber Input c ti i f ae 1 InputChannel02 A Inputchannelos PLE EE OLR Signal OFF od user Signal OFF Signal OFF USER Signal OFF eo 192 168 1 117 IN SLOT 2 Single DVI Input InputChannel06 InputChannel07 AE our 1920x1080p user Signal OFF user Signal OFF user Signal OFF Video Generator Resolut
30. ut the resolution between the formats should be same Complies with DDC HDCP Electrical DVI and HDMI cards only Supports up to WUXGA 1920x1200 at 60Hz refresh ratio for DVI or 1080P at 60Hz for HDMI and SDI Maximum 2 97Gbps bandwidth Supports 3 types of EDID management Default Mode Auto Mix Mode Output Copy Mode Supports various control methods Key buttons operation Command input Such as Hyper terminal by RS 232 and Telnet by TCP IP Web panel control TCP IP PC program by RS 232 and UDP Works with OPTICIS DVI HDMI and SDI optical extender for long signal extension Has dual power supplier for hot swappable and load sharing Equips multi viewer card to be used in various monitoring systems Provides diagnostic function for quick trouble shooting Has video generator output and monitoring output for easy installation 1 2 Shipping group OMM 1000 Modular matrix chassis 1 EA Input output cards Option SDVI 4El 4 ports electrical DVI input card SDVI 4EO 4 ports electrical DVI output card SDVI 1FI 4 ports 1 fiber optical DVI input card SDVI 1FO 4 ports 1 fiber optical DVI output card HDMI 4EI 4 ports electrical HDMI input card HDMI 4EI 4 ports electrical HDMI output card SDI 4El 4 ports electrical SDI input card SDI 4EO 4 ports electrical SDI output card QDVI O Multi viewer card AC power cord 1 EA Power supplier 1 EA Dual power supplier is an option User manual 1 EA Firmware download cable
31. ut will be connected to it To disconnect all outputs click Link Clear button 4 3 2 Input channel status Green LEDs above input channel number such as CHO5 and CH10 are signal detection from source It means only CHO5 and CH10 are connected with video sources f the green LED lit ON user can recognize the resolution of input signal ex 22 CH05 1920x1080p If LED OFF sources are not connected and it shows Signal OFF DEF AUTO OUT and USER right side of input channel number are EDID mode that is allocated for each input Refer to Chap 4 2 There are 4 slots for input cards and OMM 1000 recognizes its type during booting process and shows it on PC program when it launched Ex Slot 1 is fiber optic input card SDVI 1Fl and Slot 2 is electrical DVI input card SDVI 4EI 4 3 3 Output channel status Green LEDs above output channel number such as CHO7 is Hot Plug Detection HPD from display lt means CHO7 is connected with display But in case of fiber optic card slot 1 multi viewer card slot 4 and SDI output channel LEDs are lit ON regardless of HPD The connected outputs show input source information ex CHO7 Camera 1 input CHO5 The disconnected outputs show No Link There are 4 slots for output cards and OMM 1000 recognizes its type during booting process and shows it on PC program when it launched Ex Slot 1 is fiber optic output card SDVI 1F0 and Slot 2 is electrical DVI output c

Download Pdf Manuals

image

Related Search

Related Contents

Vivre l`aventure - Université Catholique de Lille  No Fault Found events in maintenance engineering Part 2_ Root  Philips myLiving  Lightolier DRL16 User's Manual    Avocent LongView LVIPHR  Cobalt HF TCP/IP Dashboard  3M MP8770 User's Manual  manual sda 500 - Documento sin título  PedidoContrato_Bienes_ _693-14 - Transparencia  