1. Resetting Sensor Use this function to reset the smoke detectors after an alarm has occurred Press and hold the RESET 2 key for two seconds The Flame icon will clear from the display when the Sensor Reset operation is complete and the smoke detectors are reset User Codes your code user number user code level This function allows you to Add or Delete user codes Each user is assigned 3 settings User Number how the system identifies a user User Code the four digit number a user enters into the keypad to arm disarm or to perform other system operations User Level the user is also assigned a level of authority Master Standard Limited or Scheduled to determine the functions the user can access See below for User Code authority levels Press and hold CODE key 4 until the keypad beeps once enter your user code Enter the user number 02 15 to add or delete XRSuper6 02 15 XR40 02 63 XT30 02 30 XT50 02 99 Enter four digit user code to assign to the user number or 0000 to delete an existing user Enter the authority level 1 4 Level 1 Scheduled User XR40 only The Scheduled authority level performs all the system functions of the Limited level during a valid schedule with the exception of turning Outputs on or off and System Test Disarming is allowed outside of a schedule but an Unauthorized Entry message is sent to your monitoring station Level 2 Limited User XR40 only The Limited authority
2. level can perform all the system funcitons of the Standard Level during a valid schedule with the excepton of turning Outputs on or off and System Test Disarming is allowed outside of a schedule but an Unauthorized Entry message is sent to your monitoring station Level 3 Standard User XRS6 XR20 XR40 The Standard authority level can perform all system functions except adding or deleting user codes Level 4 Master User XRS6 XR20 XR40 The Master authority level can perform all system functions Zone Status Use this function to display burglary protection zones that are faulted while the system is disarmed Any faulted burglary zones are shown in the 3 character display allowing you to correct the problem before arming SYSTEM FUNCTIONS continued SYSTEM TEST es System Test is used to test the battery alarm belt or siren and monitoring station communication Press and hold the TEST key for two seconds The System Test function begins automatically as soon as you select it Test in Progress tSt L 5 L The system is currently being tested by an installation or service technician The bell sounds for two seconds and then the communication test begins m Transmit Good tgd t 0 The communication portion to the system test was successful Transmit Failed tFL C J The communication portion of the system test failed to communicate to the Central Monitoring Station SYSTEM DISPLAYS 3 character m A Armed The s
3. lem cannot be corrected press the Select Key under BYPASS to go ahead and arm the system A zone remains bypassed until the system is disarmed If no selection is made the system will automati cally force arm any faulted burglary zones without bypassing DISARMING THE SYSTEM DISARMING WITH A CODE OF PROXIMITY CREDENTIAL When the Armed Lock icon is displaying enter your user code or present a proximity credential to disarm the entire system DISARMING DURING AN ALARM Enter your user code or present a proximity credential to silence the siren leaving the system armed After a user code is entered to silence the siren CANCEL VERIFY displays allowing you time to investigate a burglary alarm prior to disarming the system CANCEL Ifa valid alarm has not occurred choosing CANCEL disarms the system and sends a Cancel or Abort message to the Central Station VERIFY Ifthe alarmis valid choosing VERIFY sends a Verify message to the Central Station The system remains armed to provide continued intrusion detection ALERT OPERATIONS Atrouble condition on the system Azone number may be displayed Pressing any key silences the steady alert tone Steady Tone 1 One Second Beep Indicates the successful completion of a function 4 Short Beeps When an incorrect key or function is entered 1 Short Beep PANIC KEY OPERATION Top Row Select Keys Each time a key is pressed y C y Police Emergency Fire CMD MD lt Your ke
4. or disarm the system without the need to remember a user code USER FRIENDLY SHORTCUT KEYS Twelve one button shortcut keys simplify operation providing access to a variety of functions For example pressing the HOME key for two seconds arms your system when you re at home for the evening The keys enable users to quickly arm monitor zones easy exit test or reset the system and a variety of other functions PLEASE TAKE A MOMENT To learn the range of features of your system please read through this user s guide thoroughly All icons and keypad operations are completely described y 7 we FOXSECUR com TEST ICONS CANCEL BYPASS EXTEND VERIFY AC Power D On Steady AC power is good Pulsing AC power is off Battery On Steady Battery power is good Pulsing Battery power is low Open Lock The system is completely disarmed Armed Closed Lock Some or all areas are armed Status A See System Displays A H P or S Closed Lock Instant Some or all areas armed Instant See Arming the System Door Chime Door or window perimeter zone s are selected for monitor See Door Chime All burglary protection zones are normal and system is ready to arm Thumbs Up sh Thumbs is Down System is not ready to arm due to a burglary zone ina faulted state such as an open door See Zone Status Telephone Pulsing Asystem message being sent to your monitoring Handset co station failed to transmit over the telephone line Net
5. ther devices connected to outputs that you can turn on or off using the keypad Press and hold the OUTPUT 0 key until the keypad beeps Enter your user code and then the 2 digit number of the output including any leading zero such as 01 This changes the output from off to on or vise versa
6. work On Steady Your system is programmed for Network Connection A burglary alarm has occurred The zone number is shown in Phe Internet communication and functioning properly Pulsing Network Internet communication interrupted Burglar the 3 character display Afire alarm has occurred The zone number is shown in the Flame rN 3 character display ARMING THE SYSTEM ARMING WITH A CODE OR PROXIMITY CREDENTIAL While the Thumbs Up icon is displaying enter your user code or present a proximity credential to begin the exit countdown Arming is delayed until the end of the countdown Pressing the INST key during the exit countdown immediately arms the system and entry exit delays An alarm would immediately occur should an exit door be opened ARMING WITH SHORTCUT KEYS While the Thumbs Up icon is displaying press and hold the ALL HOME PERIM or SLEEP key for two seconds to arm your system ALL arms the entire system HOME or PERIM arms the Perimeter zones leaving the Interior disarmed SLEEP optional arms the Perimeter and Interior zones leaving the sleeping area disarmed ARMING WITH FAULTED ZONES THumes pown BYPASS Thumbs down displays and the keypad sounds four short beeps when a burglary zone is faulted while arming the system The zone number is shown in the 3 character display If the problem is simply an open door or window press the Back Arrow key correct the problem and try arming again If the prob
7. ypad may be programmed to send a Panic Emergency or Fire report to your monitoring station If this option is programmed for your keypad icons appear below the top row Select keys Press and hold the two Select keys adjacent to the desired icon for 2 seconds and a beep from the keypad is heard The report is sent to your monitoring station EXTENDING THE SCHEDULE EXTEND Your system may be programmed with a schedule to identify authorized disarmed periods This option displays and a steady tone sounds when the authorized disarmed period is about to expire Press the Select key under EXTEND and enter your user code to extend the schedule for an additional hour If more than one hour is needed after entering a user code press the number of hours between one 1 and the maximum nine 9 SYSTEM FUNCTIONS DOOR You can enable monitor for all Perimeter zones in the system to sound CHIME adoorbell chime at the keypad anytime a zone is opened Press and hold the CHIME 5 key for two seconds The Door icon will display and the doorbell chime sounds Pressing the CHIME key again for two seconds turns off this function 9 EASY This function allows you to exit your home while the system is armed EXIT Press and hold the EXIT 8 key until the exit countdown begins to n 8 display and then exit The system automatically arms again after the countdown completes OUTPUTS your code output number ON OFF Your system may have lights or o
8. ystem is armed ALL or AWAY Abt Alarm not sent m m z The alarm signal was aborted and not sent to the central station because a user code was entered to disarm the system or CANCEL was selected ALC Alarm not cancelled An alarm signal has just been sent to the central station and cancelled m 2 J because a user code was entered after the alarm was sent or CANCEL was selected H Home E The system is armed HOME m P Perimeter The system is armed Perimeter PERIM S Sleep The system is armed SLEEP 5 bSY System busy m 4 The system is performing other functions at this time rFA Wireless jammed alarm rFJ Trouble C m Your system may be programmed for wireless interference detection and if T displayed your wireless receiver has detected an interferring signal C rFt Wireless trouble T Your wireless receiver is unplugged or not operating properly USER S MANUAL Thinline Series icon Keypads g ee 8 iz Select keys SLEEP 7 ye EXIT E o oumurO TEST 4 i COMMAND Key ta Back Arrow Key Shortcut amp Digit Keys SIMPLE TO USE The easy to understand icons combined with a three character display provides visual feedback enabling simple arming disarming and a variety of other functions CODELESS ARMING amp DISARMING The innovative 7363 Thinline Icon Keypad contains a built in DMP proximity reader that allows you to simply present a proximity credential to the keypad to arm