Home

Electrical/Battery/Mechanical Protocols - Hardware

image

Contents

1. Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 400 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA053 US Headphone Earphone and Loudspeaker Intertek Version 1 2 Date 18 March 2010 Page 1 of 4 Requirement Document Review 1 Labelling Uniform Packaging Distributor s Name amp Address City State amp Zip Packaging or and Labelling product Regulation Product Identification Country of origin NAFTA amp FTCA Sect Country Of Origin If Imported marking 5 Physica Shall meet label claims 4 Cord Length General Measure Length of the headphone or earphone cord shall meet the claims and within 20 5 deviation aaa VisualCh
2. Basic charge Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Sample size Subject to actual sample USD 180 Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA062 US Power Inverter Intertek Version 5 Date August 10 2011 Page 1 of 3 Test requirements Reference Method DocumentReview SSS S SSS 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation 2 Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking If imported 3 Safety Certification Visual Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and model number 4 General Markings UL 458 Cls 55 56 57 The following markings shall be legible and readily visible after th
3. Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Construction Check 10 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface P
4. Turnaround time 7 working day Sample size 3 pieces Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA012 US Rechargeable Screwdriver Version 7 Date August 10 2011 Page 4 of 4 Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obl
5. s name trade name or trademark b The date or other dating period of manufacture not exceeding any three consecutive months c Adistinctive catalogue or model number or the equivalent and d The electrical rating Charger shall be marked with one of the following a Class 2 BATTERY Charger b Class 2 TRANSFORMER c Class 2 Power Supply or d Class 2 Power Unit Tools shall be provided with an instruction manual such that it is obvious when tool is removed from the carton It shall include the following major categories in the sequence given GENERAL SAFETY RULES SPECIFIC SAFETY RULES AND OR SYMBOLS FUNCTIONAL DESCRIPTION ASSEMBLY OPERATION MAINTENANCE ACCESSORIES Equivalent terms for titles of categories may be used Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA012 US Rech ble S dri Intertek Pura e Screwdriver Date August 10 2011 Page 2 of 4 UL 745 4 2 Tools shall be provided with Cls 31 Hold tool by insulated gripping surfaces when p
6. Complete test package provided upon request The sample should be reviewed against the California Proposition 65 ee cL requirements of California Proposition 65 to determine if additional testing or labeling is required LABELING BV Lab Number Technician Name Test Date Reviewed By Date Page 2 of 6 DGEN 04034 US WIRELESS HEADPHONE V11 One Time Use Products Fair Manufacturer Packer or Distributor s Name amp Packaging and Labeling Act i eee Da 16 CER Address City State amp Zip Code ackaging and Labeling Act ora 500 OR NIST Uniform ress City State ip Code other products Laws and Regulations Uniform Packaging and Labeling Handbook 130 Regulations es a me P i os al F P and L Act 16 CFR Product Identification mee B 500 OR NIST Uniform other products Laws and Regulations Uniform Packaging and Labeling Handbook 130 Regulations Net quantity of contents shall be expressed in terms of weight or mass measure numerical count or combination so as to give accurate information to facilitate consumer comparison U S and metric units One Time Use Products Fair Packaging and Labeling Act or all other products Uniform Packaging and Labeling Regulations F P and L Act 16 CFR 500 OR NIST Uniform Laws and Regulations Handbook 130 Use care instructions that are clear and understandable shall be provided in language appropriate to destination co
7. USD 300 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US battery mercury test USD 100 Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA048 US Battery Operated Reciprocating Intertek Saw Jig and Sabre Saws Version 5 Date August 10 2011 Page 1 of 5 Document Review ee ee ee Labeling Uniform Labeling Distributor s Name amp Address City State amp Zip Packaging or Regulation product Product Identification Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking 3 Safety Certification Visual Class 2 power unit shall have valid UL or ETL listing Verify Mark listing by NRTL product directory with the sample s listing number and model number 4 DOE requirement 10 CFR 430 Shall have valid DOE certifi
8. not of itself confer immunity from legal obligations Intertek Product Spec DG EA024 US 3 Outlet Holiday F X Remote Control Version 6 Date August 10 2011 Page 2 of 2 Test requirements Test Method 20 Functional Actual Use Check Additional test 21 Chemical amp DG EA065 Energy Efficiency test for all electrical items to California 22 Dollar General Client requirement Certificate of Compliance Toxics in packaging Volatile organic GC MS screening US Substances EPA method 5000 and VOC if 8021B doc review applicable Additional charge All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Shall meet the requirements in DG EA065 e All products containing CA Prop 65 warning label will be reported as FAILED Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Product with solvent based liquid eg Adhesive paints glues and etc shall not contain toxic aromatic compounds and hazard substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day S
9. or operating frequency gt 1 705Hz for Battery operated product FCC Part 15 Visual Check Marking shall include marking and This device complies with Part 15 of the FCC Rules instruction Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re
10. the values of the output current and volt amperes shall not Inherently Limited exceed those specified in Table 28 2 26 Dielectric UL 1310 Shall withstand for 1 minute without breakdown Withstand Cls 32 a One thousand volts AC plus twice the maximum rated voltage between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b One thousand volts AC plus two times the sum of secondary voltages between secondary windings for units described in 26 3 or 28 2 3 c Five hundred volts AC between a secondary circuit and dead metal parts d A DC potential of 1 414 times 2 V 1 000 where V is the RMS supply voltage between the terminals of a capacitor used for radio interference elimination or arc suppression 27 Strain Relief UL 1310 Must withstand a 35 Ibf 156 N strain for 1 minute Cls 40 28 Direct Plug In UL 1310 Each blade and the grounding pin if provided shall withstand a direct Blade Secureness Cls 41 1 pull of 20 lbf 89 N for 2 minutes without loosening The two blades Test tested together shall also withstand a direct pull of 20 Ibs for 2 minutes without loosening Shall be subjected to a single impact of 5 Ibf 6 78 N m by a 2 in 51 Cls 44 3 mm dia 1 18 Ib 535 g steel ball from a height of 51 in 1 30 m Shall not tip over at an 8 incline in the direction of least stabil ity with _ EE inserted in charger Fitness for Use for Use 31 Fitnes
11. 130 F P and L Act 16 CFR 500 OR NIST Uniform Laws and Regulations Handbook 130 Product Identification 1 BUREAU VERITAS One Time Use Products Fair Packaging and Labeling Act or all other products Uniform Packaging and Labeling Regulations Country Of Origin Use labeling Dollar General Certificate of Compliance Toxics in packaging Sharp points Sharp edges PHYSICAL CHARACTERISTICS Dimensions Weight WORKMANSHIP Handbook 130 19 CFR 134 CPSD HL 01057 MTHD Visual CPSD GB 00001 MTHD Client requirement 16 CFR 1500 48 1500 49 modified CPSD HL 01056 MTHD Standard measure CPSD HL 01056 MTHD Standard measure DGEN 04255 US UNIVERSAL REMOTE CONTROL BATTERY OPERATED V11 F P and L Act 16 CFR 500 OR NIST Uniform Laws and Regulations 1 1 Net quantity of contents shall be expressed in terms of weight or mass measure numerical count or combination so as to give accurate information to facilitate consumer comparison U S and metric units Shall indicate country of origin legibly permanently and in comparable size and close proximity to any mention of country other than country in which the article was manufactured or produced Must be visible at point of purchase Use care instructions that are clear and understandable shall be provided in language appropriate to destination countries Shall provide signed chopped document Dollar Gen
12. 6 3 4 All exposed dead metal parts that are exposed to contact during any servicing operation including maintenance and repair and that can become energized shall be electrically connected to the grounding terminal and with earth resistance not more than 0 1 Ohm Adaptor Operated Document Review 37 Safety Visual Check Shall have valid ETL UL or CSA listing for both US and Canada or Certification Mark equivalent Verify listing by NRTL product directory with the sample s listing number and model number 38 General and UL 1310 Charger shall be legibly and permanently marked Cautionary Cls 49 1 a The manufacturer s name trade name or trademark Markings b The date or other dating period of manufacture not exceeding any three consecutive months c Adistinctive catalogue or model number or the equivalent and d The electrical rating UL 1310 Charger shall be marked with one of the following Cls 49 4 a Class 2 BATTERY Charger b Class 2 TRANSFORMER c Class 2 Power Supply or Class 2 Power Unit UL 60950 1 Cl 1 7 1 Shall be legibly and permanently marked with e RATED VOLTAGE S or RATED VOLTAGE RANGE S in volts symbol for nature of supply for d c only RATED FREQUENCY or RATED FREQUENCY RANGE in hertz RATED CURRENT in milliamperes or amperes manufacturer s name or trade mark or identification mark manufacturer s model or type reference CLASS EQUIPMENT Symbol UL 60065 Cl 5 1 h
13. 745 2 4 For Belt type sanders the direction of rotation of the belt shall be indicated by an arrow raised or sunk or by any other means no less visible or indelible 6 Caution Marking UL 745 2 4 WARNING To reduce the risk of injury user must read and understand instruction manual The word Warning shall be in capital letters not less than 2 4 mm high and shall not be separated from the cautionary statement The statement shall be verbatim except the term Operator s manual or User guide may be used for the term Instruction manual 7 Caution Marking UL 745 2 4 A caution marking shall be permanent and shall be located on a part permanently attached to the tool or on a part that cannot be removed without impairing the operation or the appearance of the tool 8 Instructions UL745 2 4 An instruction manual shall be provided with the tool The instruction manual shall include the following major categories in the sequence given 1 General Safety Rules Specific Safety Rules And Or Symbols Functional Description Assembly Operation Maintenance Accessories Construction Check il 11 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 12 Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from Assembly turning Technical info
14. 86 BV A03 Wireless Headphone Rav 0404 G012 oc 5 4sosscecsicdarestadeacis eaartssadonions A A 89 4255 Universal Remote Control Battery Operated Rev 04 24 2012 ecsssesseceseceseceeeceeeeeseeeseeeeaeeeaeeeaeenaes 95 MTS BEA 91310 AC Adaptor Rev 08 1 72012 sic ccassstzsasteactosnes tntanneiea sees s iere ATE E RN ET ENOR iihi 100 Product Spec DG EA007 US Audio and Video Products Version 13 Date August 10 2011 Page 1 of 6 Document Review 1 Labelling Uniform Packaging Distributors Name amp Address City State amp Zip Packaging or and Labelling product Regulation Product Identification marking 5 3 FCC part 15 rules Visual Check FCC part 15 report shall be provided for verification if the operating frequency gt 9kHz for AC or operating frequency gt 1 705Hz for Battery operated product 4 FCC Part 15 Visual Check Marking shall include marking and This device complies with Part 15 of the FCC Rules instruction Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested
15. Appendix H for translations Instructions shall be legible and contrast with the background The instruction manual shall include the name and address street city state postal code of the manufacturer or private labeler This requirement does not preclude supplying the instructions printed on a blister pack backing card provided the tool can be removed without damaging the instructions 12 Instructions UL 745 4 11 1 Edition The instruction manual shall include the following major Section 31 2 paledoues in the sequence given GENERAL SAFETY RULES SPECIFIC SAFETY RULES AND OR SYMBOLS FUNCTIONAL DESCRIPTION ASSEMBLY OPERATION MAINTENANCE ACCESSORIES Efluivalent terms for titles of categories may be used Mercury Containing Title Rechargeable Cadmium and Lead containing batteries shall bear 3 chasing and Rechargeable Battery Recycling Act arrows or comparable recycling symbol and Battery A Ni Cd or nickel cadmium and BATTERY MUST BE Management Act RECYCLED OR DISPOSED OF PROPERLY Pub L 104 142 13 B Pbor LEAD RETURN and RECYCLE and BATTERY May 1996 Stat MUST BE RECYCLED if sealed 110 1333 Mercury Containing U S Pub L 104 142 13 Batteries larger than button cell shall contain no intentionally and Rechargeable May 1996 added Mercury No intentionally added Hg is demonstrated in Battery Including Title for this product if testing shows less than 1 ppm best practice Management Act rechar
16. CPSD EL PTCL Declaration of Conformity must be submitted with 04999 9 NA CPSD complete and correct test reports Designs claimed to EL 01096 MTHD be exempt from FCC IC equipment authorization due to an un obvious feature like electronic frequency must be submitted with acceptable supporting technical documents Federal Communications Commission FCC Part 15 industry Canada document management For children products please refer to DGEN TY PTCL 08001 US for additional testing as applicable The sample should be reviewed against the requirements of California Proposition 65 to determine if additional testing or labeling is required F j DGEN TY PTCL Children s Products 08001 US A a DGEN AN PTCL California Proposition 65 06572 US LABELING One Time Use Products Fair Packaging and Labeling Act or all other products Uniform Packaging and Labeling Regulations One Time Use Products Fair Packaging and Labeling Act or all other products Uniform Packaging and Labeling Regulations Shall pass Primary Battery Powered Product module x Primary battery powered product eee Cit Notes to lab module y to pee Dollar General Requirement p Please see performance section below for Battery Product Compartment Design Guidance test Manufacturer Packer or Distributor s Name amp P P and L Act 16 CFR Address City State amp Zip Code 500 OR NIST Uniform Laws and Regulations Handbook
17. Compliance is checked by inspection and by following tests e Test together with a fully charged battery pack e Stall the motor and operate the switch is 50 times each on period being not more than 0 5 s and each off period being not less then 10 s If in normal use an electronic control device switches off the current before opening the main contacts the number of operations is reduced to five with the electronic control device short circuited During this test no sustained arcing or undue burning pitting or welding of contacts shall occur and there shall be no electrical or mechanical failure Switches are also tested for DC operation in accordance with the relevant component standard given in Appendix E or as an alternative subjected to 6000 operations of making and breaking at the normal no load current and at the voltage encountered in the fully charged tool The tests shall not result in ignition of the switch materials and the switch shall complete the tests without loss of on off control or unexpected turn on Power Draw Ammeter DC power Measure DC current draw under normal use condition at nominal suppl voltage 34 Shall withstand 50 cycles without defect 37 Elevated Impact In house method If applicable handheld products to be used around the face or Resistance head shall sustain no permanent damage shall be sustained by unit from drop from 1 5 meters Opening of battery case is acceptable Fitness for Use
18. Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA040 US High Pressure Cleaning Machines Version 8 Date August 10 2011 Page 2 of 4 Test requirements Reference Method Electrical Safety JE E 15 Component Check Visual 16 Dielectric Voltage UL 1776 Cls 83 Withstand Test Leakage Current Test UL 1776 Cls 77 Strain Relief UL 1776 Cls 88 Surface temperature UL 1776 Cls 67 2 test 20 Overflow test UL 1776 Cls 84 3 Mod If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking The unit shall withstand the dielectric voltage withstand test without breakdown for a period of 1 min when a test voltage as stated below is applied between a live part and any accessible part For primary circuit lt 1 2 horsepower and 250 volts or less 1000VAC gt 1 2 horsepower or more than 250 volts 1240VAC For secondary circuit The secondary operates at 251 600 volts 1240VAC The secondary operates at 51 250 volts 1000VAC The secondary operates at 50 volts or less 500VAC Under rated input voltage rated loading and thermally stabilized the measured leakage current shall not more than a 0 5 milliampere for a portable product and b 0 75 milliampere for a product int
19. FTCA Sect Shall mark with Country Of Origin If Imported 5 Safety Visual Shall have valid UL or ETL listing Verify listing by NRTL product Certification directory with the sample s listing number and model number Mark General and UL 773A The product shall be marked with Cautionary Clause 37 Manufacturers name trade name or trademark Markings model number electrical ratings date code other safety markings required by the standard User Manual UL 773A Instructions and warnings shall be provided in the user manual Important Safety Clause 38 identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assembly maintenance Instructions 6 FCC part 15 Visual Check FCC part 15 report shall be provided for verification if the operating rules frequency gt 9kHz for AC or operating frequency gt 1 705Hz for Battery operated product FCC Part 15 Visual Check Marking shall include marking and This device complies with Part 15 of the FCC Rules instruction Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for complia
20. Markings UL 1449 Cls 61 5 Instructions UL 1449 Cls 62 6 __ Parts Inventor ConstructionCheck 7 _ Packing Distributors Name amp Address City State amp Zip Product Identification Country Of Origin If Imported Shall have valid UL or ETL listing Verify listing by NRTL product directory with the sample s listing number and model number A TVSS shall be plainly and permanently marked with Manufacturer s Name or Trademark Distinctive catalog number or equivalent Electrical rating Suppressed voltage rating Date of manufacture The words Transient Voltage Surge Suppressor or TVSS An instruction provided with the product shall include the following a Instructions for installation Instructions for permanently wired devices shall include minimum and maximum wire length and gauge sizes the ampacity of the circuit the device is intended for use on and the internal wiring methods showing location and routing b Instructions for mounting c An explanation of the purpose and function of any indicator lights audio indicators and similar indicators features employed on the TVSS d The interrupting rating of any required Shall meet label claims No hazard when removing the packing Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 9 Mechanical Assembly V
21. RMS supply voltage between the terminals of a capacitor used for radio interference elimination or arc suppression 31 Strain Relief UL 1310 Must withstand a 35 Ibf 156 N strain for 1 minute Cls 40 32 Direct Plug In UL 1310 Each blade and the grounding pin if provided shall withstand a direct pull Blade Secureness Cls 41 1 of 20 Ibf 89 N for 2 minutes without loosening The two blades tested Test together shall also withstand a direct pull of 20 lbs for 2 minutes without loosening 33 Impact Test UL 1310 Shall be subjected to a single impact of 5 Ibf 6 78 N m by a 2 in 51 mm Cls 44 3 ia 1 5 i in 1 Battery operated Electrical Safety polarit chemical leakage shall not occur overcharge test explosion or chemical leakage shall not occur 36 Battery short UL 60065 For rechargeable battery with full charge battery installed and short circuit test CI 14 10 1 circuiting the positive and negative terminals of the battery with a resistor of Modify with test 0 1 ohm max temp at 20 degC only and sample During and after test the battery shall not explode or catch fire or chemical size to 1 leaks Temperature of battery pack casing shall not exceed 150 degC Additional test eS eee eer 37 With Child DG EA051 Shall meet the requirements in DG EA051 Appealing Features Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Co
22. SUE SJEOO SJO SUT SUTO SP 3 or SPT 3 flexible cord with a grounding conductor The length of supply cord external to the converter or inverter shall not be more than 3 feet 914 mm measured from the face of the attachment plug to the point of entry Electrical Satety 14 Dielectric Strength UL458 Cls 39 Mod A converter or inverter at the maximum operating temperature reached in normal use shall withstand for 1 minute without breakdown the application of a 60 hertz essentially sinusoidal potential o ofne thousand volts plus twice the maximum rated voltage 1 Between the primary circuit and dead metal parts 2 Between the primary and secondary circuits and 15 Leakage Current Test UL 458 Cls 32 The leakage current on accessible part of a cord connected inverter rated for a nominal 120 volt supply shall not be more than 0 75mA Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA062 US Power Inverter Version 5 Date August 10 2011 Page 2 of 3 Test requirements Reference Meth
23. Test i i a 24 With Child DG EA051 Shall meet the requirements in DG EA051 Appealing Features 25 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California 26 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging 27 Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC if 8021B doc review applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional charge Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 200 Additional charge DG EA051 80 exclude chemical tes 12 sets Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical infor
24. Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA007 US Audio and Video Products Version 13 Date August 10 2011 Page 2 of 6 Test Item Test Method 8 Workmanship Visual Check Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 9 Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from turning Assembl Construction Check 10 Internal Wiring Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts Fitness for Use 11 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 12 Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 13 Ease of Cleaning
25. cord shall be green with or without one or more yellow stripes The grounding conductor of a power supply cord and any internal wiring connection used for grounding shall be secured such that the connection is not likely to be unintentionally disconnected during any servicing operation Servicing as mentioned here includes repair of the product by a qualified service person Solder alone shall not be used for securing a grounding conductor 22 Enclosures and UL 1776 Cls 49 The rotor of a motor or a pulley belt gear fan or other moving Guards part that could cause injury to persons shall be enclosed or guarded to reduce the likelihood of unintentional contact therewith Fitness for Use i es FF E FA IA 23 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 24 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 25 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be Wipe Gently with Damp replaced easily and not causing any safety hazards Cloth QS SE a Additional test 26 Chemical amp Energy DG EA0
26. electric shock from an uninsulated live part or film coated wire and Film Coated Wire an opening in an enclosure shall a Be spaced from the opening as specified in standard if the opening has a minor dimension of 1 inch 25 4 mm or more and b Not be contacted by the probe illustrated in standard if the opening has a minor dimension see 15 4 less than 1 inch 25 4 mm 13 Power Cord UL 1776 The flexible cord shall be a Type SJ SUE SJO SUT SUTO Cls 16 1 3 amp 16 1 6 SJO or SUTOO for a portable product employing a motor rated 2 horsepower 1492 W or less Portable products employing a motor rated more than 2 horsepower and stationary products shall employ Type S ST STO SOO or STOO flexible cord For a portable product the flexible cord shall be at least 35 feet 10 67 m long For stationary products the flexible cord shall be at least 3 feet 0 91 m long and not longer than 4 feet 1 21 m The measurement of the length of the flexible cord is to include the attachment plug 14 Plug Visual Check Plug shall be 3 wire grounding type or 2 wire polarized attachment plug Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use
27. enclosure Piinssetnr igs P Not Applicable Output Rating noses with specific product the maximum input rating of the product shall not exceed the maximum output rating of the Note It is the Vendor s responsibility to ensure that the products comply with all United States Federal States and local laws regulations and ordinances A Pass Lab test result does not constitute a certification that a vendor s products meet all legal requirements It is the vendor s responsibility to manufacture their items to comply with all applicable laws and in conformance with the purchase order terms and conditions Pre Production Review Result Key Packaging Review Product Specification Review Pass Pass with Remark Complete Complete Fail Incomplete Documentation Review Documentation Provided Complete index of report Documentation Not Provided Incomplete TAT 5 7 working days Protocol Version V1 Revision Date 21 Jun 12 Client Approval Version History New creation 21 Jun 12 Page 4 of 4
28. in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA058 US Digital Photo Key Chain Intertek Version 5 y Date Aug 16 2011 Page 1 of 2 Test requirements Reference Method Document Review _ ee 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation 2 Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking If imported 3 Parts Inventory Shall meet label claims 4 General and Visual Check A general cautionary and warning marking intended to inform Cautionary Markings the user of a potential risk of fire electrical shock or injury to persons shall be provided 5 User Manual Visual Check Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regarding the Assembly Instructions installation use safety and maintenance 7 US FCC Part 15 Visual Marking shall include marking and FCC logo trade name model number instruction
29. include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA049 US Portable Electric Sander Intertek Version 6 Date August 10 2011 Page 1 of 4 Document Review Ss SSS Yy Labelling Uniform Labelling Distributors Name amp Address City State amp Zip Packaging or Regulation product Product Identification Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking 3 Safety Certification Visual Class 2 power unit shall have valid UL or ETL listing Verify Mark listing by NRTL product directory with the sample s listing number and model number 4 General marking UL745 2 4 rated voltage s or rated voltage range s in volts symbol for nature of supply if applicable rated frequency or rated frequency range in hertz unless the tool is designed for d c only or for a c of both 50 Hz and 60 Hz rated input if greater than 25 W in watts or kilowatts or rated current in amperes manufacturer s name trade mark or identification mark manufacturer s model or type reference rated operating time or rated operating time and rated resting time in hours minutes or seconds if applicable symbol for Class II construction for Class II tools only rated no load speed date of manufacture 5 Belt Rotation Marking UL
30. instructions User instructions explanation of the symbol A symbol marked above shall be explained in the instructions Construction Check 3 Ei 9 Wi EB AF YEU 9 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Assembly edges or moving parts 12 Plug UL 60950 1 The attachment plug of the power supply cord of an appliance intended Clause 3 2 1 to be connected to a nominal 120V circuit and provided with a 15 or 20 ampere general use receptacle shall be of the 3 wire grounding type Length Clause 3 2 5 1 and length of flexible cord per section Ss ee eee ee Electrical Safety 14 Component Visual If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 15 Dielectric Voltage UL 60950 1 The insulation and spacing shall withstand the dielectric voltage Withstand Test Clause 5 2 withstand test without breakdown applied between a live part and any accessible part 2000Vac 1min Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the nec
31. maximum rated voltage between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b One thousand volts AC plus two times the sum of secondary voltages between secondary windings for units described in 26 3 or 28 2 3 c Five hundred volts AC between a secondary circuit and dead metal parts d A DC potential of 1 414 times 2 V 1 000 where V is the RMS supply voltage between the terminals of a capacitor used for radio interference elimination or arc suppression 29 Strain Relief UL 1310 Must withstand a 35 Ibf 156 N strain for 1 minute Cls 40 30 Direct Plug In UL 1310 Each blade and the grounding pin if provided shall withstand a direct Blade Cls 41 1 pull of 20 Ibf 89 N for 2 minutes without loosening The two blades Secureness Test tested together shall also withstand a direct pull of 20 lbs for 2 minutes without loosening Shall be subjected to a single impact of 5 Ibf 6 78 N m by a 2 in 51 Cls 44 3 mm dia 1 18 lb 535 g steel ball from a height of 51 in 1 30 m Battery operated _Electrical Safety polarity or chemical leakage shall not occur overcharge test explosion or chemical leakage shall not occur 34 Battery short UL 60065 For rechargeable battery with full charge battery installed and short circuit test Cl 14 10 14 circuiting the positive and negative terminals of the battery with a Modify with test temp resistor of 0 1 ohm max at 20 d
32. more and the length of input cord is gt 3 feet UL 60950 1 Cls 3 2 1 1 The unit shall be provided with termnials for permanent 3 2 5 1 connection to the AC Mains supply or a non detachable power supply cord Power cord cross sectional area shall not be less than those specified in table 3B Plug shall be 3 wire grounding type or 2 wire polarized attachment plug Electrical Safety D ee 17 Component Check Visual If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking Dielectric Strength UL 1310 Cls 32 Shall withstand for 1 minute without breakdown Test a 1240VAC between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b 500VAC between a secondary circuit and dead metal parts between AC mains and accessible part Leakage Current Test UL 1310 Cls 26 Under rated input voltage rated loading and thermally stabilized the measured leakage current shall not exceed a 0 5mA for portable unit b 0 75mA for stationary unit UL 60950 1 Cls 5 1 The measured value shall not exceed the relevant limits in table 5A Strain Relief UL 1310 Cls 41 Supply cord shall withstand a 35 Ibf 156 N strain for 1 minute For units employing a flexible output cord the cord shall subject to a 20 Ibf 89N for 1 minute without damage UL 60
33. provided That states Do not dispose of batteries in fire Batteries may explode or leak or the equivalent Cadmium and Lead containing batteries shall bear 3 chasing arrows or comparable recycling symbol and A Ni Cd or nickel cadmium and BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY B Pb or LEAD RETURN and RECYCLE and BATTERY MUST BE RECYCLED if sealed Batteries larger than button cell shall contain no intentionally added Mercury No intentionally added Hg is demonstrated in this protocol if testing shows less than 1 ppm best practice Batteries of button cell size are allowed small amounts of added mercury but shall test to less than 25 mg Hg cell Testing is required on all included alkaline manganese batteries zinc carbon Heavy Duty batteries and silver oxide and zinc air button cells Ifa button cell is found to have intentionally added mercury such as by testing at over 1 ppm RI CT NY and VT require product containing mercury have labeling to indicate the presence of mercury and instructions on how to properly dispose of the product Requirements vary by state Registration with IMERC may be required Product or packaging for items with button cells found to have intentionally added mercury that may be distributed to states with Mercury legislation shall be Marked so as to be clearly visible prior to the sale and Product itself shall be marked permanently for the life of
34. report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA017 US Intertek Relocatable Power Tap Version 7 Date August 10 2011 Page 3 of 3 Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if an
35. scratches on the external surface Peeling of rating or caution warning label Assembl turning points edges or moving parts 22 Enclosure Strength Must withstand a 5 Ib static load over 0 2 in DIA with no exposure of non insulated electrical parts electrical parts 24 Battery Charger As claimed Type If Applicable EN Electrical Safety EE 25 Component Check Visual Check If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking 26 Current Power Must not be more than 110 of rating Section 35 2 27 Leakage Current lt 0 5 mA between surface and ground Section 26 UL 1310 4 28 Dielectric Withstand Edition Shall withstand for 1 minute without breakdown Section 32 1 a One thousand volts AC plus twice the maximum rated voltage between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b One thousand volts AC plus two times the sum of secondary voltages between secondary windings for units described in 26 3 or 28 2 3 c Five hundred volts AC between a secondary circuit and dead metal parts d A DC potential of 1 414 times 2 V 1 000 where V is the rms supply voltage between the terminals of a capacitor used for radio interference elimination or arc suppression 29 Cord Length UL 13104 Edition The blade assembly for conn
36. set for an extended period of time greater than 90 days please consider hard wiring a permanent outdoor use receptacle rated for year round use in the area that power is needed Please contact a Licensed electrician for proper installation of permanent wiring e After completion of installation the connector shall be maintained a minimum of 6 inches above ground T a M a M a A E a E E T a O Visual Workmanship yout ______ Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label turning points edges or moving parts 11 Flexible Cord UL 2438 Cls 6 The sample shall be of the size and type specified in standard and shall have a minimum flame rating of VW 1 and minimum insulation temperature rating of 105 221 F A pr oduct containing more than 3 outlets shall employ either a minimum of 12 AWG flexible cord or 14 AWG flexible cord and an overcurrent protective device Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal ob
37. shall be legibly and permanently marked a Manufacturer s name trade name or trademark b A distinctive catalogue or model number or the equivalent c The date or other dating period of manufacture not UL 1310 Cls 54 exceeding any three consecutive months d Rated voltage Frequency Input in amperes volt amperes or watts g For Indoor Use Only Caution or warning markings in English A general cautionary and warning marking intended to inform the user of a potential risk of fire electrical shock or injury to persons shall be provided Maker s or responsible vendor s name or trade mark model number other markings required by the standard Cautionary markings where required shall be in letters no less than 1 8 high as required Dry location units shall be marked CAUTION and Risk of Electric Shock and the following or equivalent Dry location UL 1310 Cl 52 use only or Do not expose to liquids vapour or rain Battery Chargers shall be marked as required regarding the batteries that are to be charged Direct Plug in units shall be marked CAUTION Risk of Fire or Electric Shock Do not replace this plug assembly Other markings required per section UL 60950 1 Cls 1 7 A cautionary or warning marking intended to inform the user of a potential risk of fire electrical shock or injury to persons shall UL 60950 1 Cls 1 7 be provided Instructions and warnings shall be pr
38. size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US DG EA051 USD 80 exclude chemical test 12 pieces Remark 1 If the product is declared as toys it shall also be evaluated with the toys protocol 2 Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA061 US Booster Cable Intertek Version 5 Date August 10 2011 Page 1 of 2 Test requirements requirements Reference Method Method Requirement SSS NA uirement Document Review Labelling Packaging See Labelling SE Ne Ws ooo Name amp Address City State amp Zip or product Regulation Product identification i s s sSY marking If imported Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and model number General and UL
39. to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obl
40. to the AC Mains supply or a non detachable power 3 251 supply cord Power cord cross sectional area shall not be less than those specified in table 3B Not Applicable Visual Check Plug shall be 3 wire grounding type or 2 wire polarized attachment plug Documentation Component Check Visual listing safety report provided report any difference of component used in the sample and the listing report Exclude Review astic material insulation material or other components without marking D Shall withstand for 1 minute without breakdown a 1240VAC between Documentation Dielectric Strength UL 1310 Cls 32 1 The primary circuit and accessible dead metal parts and Review Test 2 The primary and secondary circuit or circuits b 500VAC between a secondary circuit and dead metal parts U UL 60950 Cls 5 2 nit shall withstand for 1 minute without breakdown 2000VAC between AC mains and accessible part Under rated input voltage rated loading and thermally stabilized the measured leakage current shall not exceed i Documentation UL 1310 Cls 26 a 0 5mA for portable unit Electrical Safety Review Leakage Current Test b 0 75mA for stationary unit Electrical Safety UL 60950 1 Cls 5 1 The measured value shall not exceed the relevant limits in table 5A UL 1310 Cls 44 Supply cord shall withstand a 35 Ibf 156 N strain for 1 minute oe For units employing a flexible output cord the cord shall subject to a 20 Ibf 89N for 1 minute without dama
41. user friendliness problems 23 Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 24 Ease of Follow Instructions or Follow the cleaning instruction Removable parts shall be replaced Cleaning Wipe Gently with easily and not causing any safety hazards Damp Cloth ECEE Additional test 25 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy e All products containing CA Prop 65 warning label will be reported as Efficiency test FAILED for all electrical items to California Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA028 US Photoelectric Switch Intertek Version 6 Date August 10 2011 Page 3 of 3 Test requirements Test Method Requirement Principle 26 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Complia
42. 1839 Cls 9 Shall be legibly and permanently marked CautionaryMarkings Manufacturer s name trade name or trademark or other descriptive marking A distinctive model number or the equivalent The current rating Minimum temperature rating The date or other dating period of manufacture not exceeding any three consecutive months For polarity identification one clamp shall be black and the other clamp shall be a contrasting color other than white at each end of the battery booster cable set In addition the contrasting color clamps shall be marked and POS or POSITIVE the black clamps shall be marked and NEG or NEGATIVE 5 Cautionary Markings UL 1839 Cls 10 Instructions 10 1 6 10 1 21 shall be provided as a tag permanently secured to the product The instructions shall be preceded by the heading INSTRUCTION FOR JUMP STARTING AN ENGINE Upper case letters shall not be less than 2 0 mm 5 64 high and lower case letters shall not be less than 1 6 mm 1 16 high Warning markings shall be prefixed by WARNING which shall not be less than 3 2 mm 1 8 high and remaining letters shall not be less than 1 6 mm 1 16 6 Package Instructions UL 1839 Cls 11 The tag instruction described in 10 1 3 and the instructions described in 11 2 11 11 shall appear on the package or carton The text of the instructions shall be verbatim or in equally definitive terminology These in
43. 21 Mold Stress Relief UL 2438 Cls 15 The devices are to be placed in a circulating air oven maintained Test at a temperature of 70 158 F for 7 hours The d evices are to be removed from the oven and allowed to cool to room temperature before determining compliance As a result of temperature conditioning there shall not be any warpage shrinkage or other distortion that described in standard Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA038 US Outdoor Seasonal Use Cord Connected Wiring Devices Version 7 Date August 10 2011 Page 3 of 4 Test requirements 22 Impact Test Fitness for Use 23 Functional Check 24 Ease of Installation 25 Continuous Operation Additional test 26 Chemical amp Energy Efficiency test for all electrical items to California Dollar General Certificate of Compliance Toxics in packaging UL 2438 Cls 28 The impact is to be produced by dropping or swinging a 2 inch 50 8 mm diameter steel sphere weighing 1 18 lbs 0 535 kg from a heigh
44. 65 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances VOC if EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA040 US High Pressure Cleaning Machines Version 8 Date August 10 2011 Page 4 of 4 Turnaround time 7 wo
45. 817 Under maximum current loading the overcurrent protective device shall Test Cls 87 not open the circuit the enclosure surface receptacle contacts and separation of the supply cord shall not attain excessive temperature rise as follows Supply Cord As per rating of supply cord Blade of male fitting 30K 18 Strain Relief UL 817 A 35 pound 16 kg weight is to be suspended from the cord for 1 minute so that the force is applied in a direction normal to the plane of the surface containing the cord opening or bushing Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA018 US Extension Cord Sets Version 7 Date August 10 2011 Page 2 of 2 Intertek Test Items Test Method Test Requirements Continuity of In House Method The impedance between the point of connection of the equipment grounding ae means and any accessible metal part shall be less than 0 1 connection Continuity Test In House Method ea product shall be tested to determine that continuity between all blades and pin of attachment plug and
46. 950 1 Cls 3 2 6 Power supply cord shall withstand the following pull force for 25 times 1 second each Mass of equipment kg lt 1 30 N 1 lt Mass of equipment kg lt 4 60 N Mass of equipment kg gt 4 100 N Temperature Test UL 1310 Cl 33 Surface temperature of any accessible surface should not exceed a temperature rise of more than 90 F 50 C UL 60950 1 Cls 4 5 Maximum temperature shall not exceed limits specified in Table Mod 4B part 2 Modified accessible parts Continuity of In house method All exposed dead metal parts that are exposed to contact during Grounding any servicing operation including maintenance and repair and Connection that can become energized shall be electrically connected to the grounding terminal and with earth resistance not more than 0 1 Ohm Direct Plug In Blade In house method Each blade and the grounding pin if provided shall withstand a Secureness Test direct pull of 20 lbf 89 N for 2 minutes without loosening The two blades tested together shall also withstand a direct pull of 20 los for 2 minutes without loosening 24 Impact Test UL 1310 Cls 46 2 A sample is to be dropped free fall 3 times in succession from a height of 3 feet onto a hardwood surface After test the unit shall pass dielectric voltage withstand test Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibit
47. Content of Substrate Materials 25USD per coating California Phthalates Content Requirement 150USD for 6 chemicals 120USD for 3 chemicals According to DG s requirement phthalates test would apply to this electrical item For additional charge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA059 US Video Game Console Intertek Version 5 Date August 10 2011 Page 1 of 4 Method Document Review p 1 Labelling Uniform Labelling Distributor s Name amp Address City State amp Zip Packaging or Regulation product Country of origin NAFTA amp FTCA Country Of Origin If Imported marking If Sect 5 imported FCC part 15 rules Visual Check For wireless product FCC part 15 certificate and report shall be provid
48. DPHONE V11 Shall be marked on the battery or package Designation Polarity of terminal Name or trade mark of the manufacturer or supplier Battery electrochemical system Nominal voltage Year month week or day of manufacture which may be coded or the expiration date Warnings or cautionary notes where applicable Caution for ingestion Recycle mark Cadmium and Lead containing batteries shall bear 3 chasing arrows or comparable recycling symbol and Ni Cd or nickel cadmium and BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY Pb or LEAD RETURN and RECYCLE and BATTERY MUST BE RECYCLED if sealed Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Shall have no sharp points edges other than those required for function Mod expanded scope to other products Report overall dimensions shall meet label claims If applicable 0 5 Report overall weight shall meet label claims If applicable 0 5 BV Lab Number Technician Name Test Date Reviewed By Date Page 3 of 6 BV Lab Number Technician Name Test Date Reviewed By Date Page 4 of 6 DGEN 04034 US WIRELESS HEADPHONE V11 Evaluation Citation Method Ne of Samples Shall have no discernible surface degradation Defects CPSD HL 01057 All including stains deformations rupture fabric defects MTHD Visu
49. Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC if 8021B doc review applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 200 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Additional charge for FDA Food Simulation Plastics 180 to 335USD depend on type of plastics Plastic Type Sample size Testing Time Testing Charge Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety con
50. E 38 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 39 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 40 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be Wipe Gently with Damp replaced easily and not causing any safety hazards Cloth C T Additional test Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA048 US Battery Operated Reciprocating Intertek Saw Jig and Sabre Saws Version 5 Date August 10 2011 Page 5 of 5 41 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label w
51. E This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Construction Check oC S eT OR O 10 Packing No hazard when removing the packing 11 Parts Inventory Shall meet label claims 12 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Assembly edges or moving parts 15 Plug UL 60950 1 CI 3 2 1 The att
52. Electrical Battery Mechanical Protocols Hardware Click on BLUE to go directly to page ITS 007 Portable Audio Video Device Rev 08 15 2011 ccccscccsscscsssssssssssssscsescscscsvsssssscsescstscscscssscssesesescscacsescsesesesessseeseseasars 2 DES Telephoie Speaker Call ID Rev 085 201 I oarenien iia i aAA 8 012 Battery Operated Tools Screwdrivers Wrenches amp Drills Rev 08 15 2011 cscceseeeeeeeeseseseneneneeeeeees 12 013 Fischlight and Spotl oie Mev OSONT ereire ar si uane EE ETE AS AE r N E ties 16 016 Automotive 12 V Electrical Products Rev 08 15 2011 cccccccccccccscsesccescsescscscssscsescsescscssesscssssesscesssesecscs 18 Diy Relocatable Power Taps tew OGG occoron e a E R 21 018 Cord Sets Power Supply Cords Rev 08 1320 IJ sss cscoacessacsrt a easctsteaseanateninsnoiussacinsesseisndedneasttunsoaditiesodiabeaseiontes 24 022 Elecimig Paper Shredder Rev 010I ecinic eeraa Eee a EEEE iE EANO ENEAN EOKA 26 024 Appliance Remote Control Rev 08 15 2010 ices ccssasscscsincsenussusnssicentssauedtunhdcinnsentediiaseedauiverneaduaseedanivannas 29 026 Current Taps and Adapters Rew 0S S200 15 arer eniri riisin EnN orrea EAEN DAE EOAR 31 027 Clock Timer Electrie Switch Rev O81 S201 T suseso nedirete node oianean ESATA ERRE IAOEE 33 028 Phowelecine S wate Ra BAAS 2011 cana a E E A N NENNE 36 032 Corded Telephone Answering Machine Caller ID Rev 08 15 2011 cescceseeecesseeceeececeeeeeesaeceeaeeceenees 39 033 AC Adaptor i herens ken
53. FCC Verification or Declaration of Conformity must be submitted with complete and correct test reports Designs claimed to be exempt from FCC equipment authorization due to an un obvious feature like electronic frequency must be submitted with acceptable supporting technical documents Packaging Supplemental Review FCC PART 15 IC Protocol Documentation PES PART ISIC EL 999 9 US Review Supplemental Documentation TOX Pa oe a TOX SP 002 US Shall meet the specific requirement in the protocol Chemical amp Energy Efficiency test for all electrical items to California Dollar General Labeling Documentation Certificate of Client requirement Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Review Compliance Toxics Client requirement in packaging Supplemental Protocol Shall meet the requirements in protocol of California Chemical amp Energy Efficiency requirement Packaging Review SP CEC400 US Shall be labeled with the following information 1 Product identification UPER NIST Uniform Laws and 2 Manufacturer Packer or Distributor s Name amp Address City State amp ZIP Code Labeling Packaging Review Products WITHOGE Regulations Handbook 3 Net quantity of contents shall be expressed in terms of weight or mass measure numerical count or combination so as to consumable 130 give accurate information to facilitate consumer comparison components Client requi
54. Follow Instructions or Follow the cleaning instruction Removable parts shall be replace easily Wipe Gently with and not causing any safety hazards Damp Cloth 14 Video Recording Actual Use All features must operate as intended Operation if applicable if applicable applicable program It shall be virus free 17 Supported Actual Use Windows ME Windows 2000 Windows XP Vista Others according Operating System to the claimed information if applicable 18 Software Software installation amp Provided software shall be usable in PC and no difficult during installation amp Usage if applicable installation Usage if applicable 19 Durability of In house method Switches shall continue to function correctly after 100 cycles of Switches if operations applicable applicable 21 Expandable Expandable Memory As specified by manufacturer shown on manual label Memory if if applicable applicable 22 Memory Media In house Method As specified by manufacturer shown on manual label Type if applicable Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from l
55. SIBLE the Live Parts jointed test finger according to test probe B of IEC 61032 Figure 14 is pushed against the enclosure or inserted through any openings of the enclosure including openings in the bottom without appreciable force 20 Temperature Test UL 60950 1 Cl 4 5 Record the maximum operating temperature of enclosures Mod Mod Accessible surfaces only which shall not exceed the following requirements Enclosure 70 C Knobs 60 C Handset 50 C 21 Strain Relief UL 60950 1 CI 3 2 6 Strain relief shall be provided to prevent a mechanical stress on a flexible cord from being transmitted to terminals splices or interior wiring consumption power output of the AC adaptor polarity Cl 4 3 8 or chemical leakage shall not occur With full charged battery installed and charge for additional 7 hours overcharge test Cl 4 3 8 explosion or chemical leakage shall not occur 25 Leakage current UL 60065 Cl 9 1 1 1 The leakage current of unit shall be below limits required Class product less than 3 5mA Class II product less than 0 7mA l Fitness for Use eee ee er 26 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 27 Ease of Actual Use Follow directions for installation in Instruction manual Report rela
56. TA amp If imported country of origin marking shall be provided and clearly FTCA Sect 5 indicated to the ultimate purchaser of a product where it is made 3 Safety listing mark Document Check Shall have valid UL or ETL listing or equivalent Verify listing by NRTL product directory with the sample s listing number and model number General and UL 1363 Cls 38 Shall be permanently and clearly marked on the outside of the Cautionary Markings enclosure with a Manufactures name trade name trademark or other descriptive marking which identifies the organization responsible for the product b Catalogue number or equivalent c Rating in voltage and amperes d Date of manufacture User Manual UL 1363 2ed Cls 38 Instructions and warnings shall be provided to identifying Important Safety reasonable foreseeable uses or misuses of the product Instructions All accessories shall be described in the user s manual and provided Assembly Instructions with instructions for proper use Construction Check Workmanship Visual Check Shall have no major defects such as external Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 9 Workmanship Visual Check Solder connections shall be secured internal Components shall be reliably mounted on PCB or other proper fixing 10 Internal Wires Visual Check Wireways shall be smooth and entirely free from sh
57. achment plug shall have a current rating no lower than 125 of the current drawn by the apparatus under normal operating conditions and a voltage rating appropriate for the rated voltage for the apparatus Length and length of flexible cord per section Electrical Safety a eee 17 Component Visual If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 18 Dielectric Voltage UL 60950 1 CI 5 2 The electric strength shall be adequate between telephone line and Withstand Test accessible parts Mains to handset 1500Vac Mains to enclosure 1000Vac Telephone line to handset 1500Vac Telephone line to enclosure 1000Vac Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA032 US Cordless Telephone Anwering Machine Caller ID Intertek Version 9 Date Aug 16 2011 Page 3 of 3 19 Accessibility of UL 60950 1 CI 2 1 1 1 To determine whether a HAZARDOUS LIVE part is ACCES
58. al or unraveling Defects CPSD HL 01057 All Shall have no components missing malformed and or MTHD Visual fractured PERFORMANCE Not already covered by other tests i P U Shall function as intended as received Report details Functionality MTHD CPSD EL All of evaluation features tested methods used 01039 MTHD materials used etc Report any features not evaluated Durability butt CPSD HL 01058 Buttons Must Withstand 100 Cycles Of Use ie a MTHD Actual use Drop Test CPSD EL 01032 1 3 drops from 1 meter on hardwood flooring Report p MTHD discrepancies and drop number Adjustment ear piece CPSD HL OTs 1 aa ee T ee diia Oe J P MTHD Actual use 8 Sound qualit Actual use CPSD HL 1 Shall provide clear sound with no hissing or audible eee 01058 MTHD distortion pant pcunilvel ae Psp ony bared volo calag andl Npoulbarc ofise applicable MTHD Actual use y 1 E CPSD HL 01058 Report the claimed operation range Shall be function Operational Range 1 at claimed range If no claim the device shall be MTHD Actual use function at distance of 5 m Transmitter CPSD HL 01058 1 Should Operate Across Claimed Frequency Range MTHD Actual use Observe Effect Or Non Effect Of Using Product CPSD HL 01058 Around Normal Home Office Appliances TV Stereo Interference MTHD Actual use Stereo Speakers Computers Fluorescent Lights Etc No Interference Shall be Observed BV Lab Number Technicia
59. all be legibly and permanently marked with maker s or responsible vendor s name trade mark or identification mark model number or type reference CLASS EQUIPMENT Symbol nature of supply RATED SUPPLY VOLTAGE or range of the RATED SUPPLY VOLTAGES rated MAINS frequency or range of frequencies in hertz RATED CURRENT CONSUMPTION or RATED POWER CONSUMPTION RATED CURRENT CONSUMPTION or RATED POWER CONSUMPTION date or a dating code of manufacture UL 60950 1 Cls 1 7 Instructions and warnings shall be provided in the user manual UL 60065 Cls 5 4 identifying reasonable foreseeable uses or misuses of the product It shall also include instructions regarding the installation use safety and maintenance 39 DOE requirement 10 CFR 430 Shall have valid DOE certification report for verification It is the vendor s responsibility to submit the certification report and compliance statement to DOE Electrical Safet e N 9 o eee Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA007 US Audio and Video Products Versi
60. all include marking and i AAAEQ TXXX instruction AAA responsible party s grantee code EQ equipment code ringer equivalence number T ringer type XXX product identifier HAC for telephone only 8 FCC part 15 Shall provide FCC part 15C report for verification Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA032 US Cordless Telephone Anwering Machine Caller ID Intertek Version 9 Date Aug 16 2011 Page 2 of 3 9 FCC Part 15 Visual Marking shall include marking and FCCID instruction This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOT
61. ample size 2 pieces Testing charge Sample size Basic charge USD 150 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample 1 Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample 2 Different UL standard comply with these kind of products depend on the features and outlook of it The applicable UL standard will be advised when received the real sample of this kind of product Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA026 US Current Taps and Adapters Intertek Version 7 Date August 10 2011 Page 1 of 2 Test Method Principle Requirement DocumentReview Labelling Uniform Labelling Distributor s Name amp Address City State amp Zip Packaging or Regulation product Product Identification Country of ori
62. ance shall be provided with an appropriate type Length UL 1492 Cls 24 1 and length of flexible cord per section 24 2 Electrical Safet 30 Electrical Safety Visual Check If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other without marking components 31 Dielectric Voltage UL 60065 Cls 10 3 An appliance shall be capable of withstanding for 1 min when a test Withstand Test voltage of 4240 VAC peak is applied between live parts and accessible metal parts without an indication of unacceptable performance UL 1492 Cls 71 No breakdown occurs at 1000Vac 1 min between AC mains and accessible parts UL 60950 1 Cls 5 2 2 No breakdown occurs at 3000Vac 1 min between AC mains and accessible parts Accessibility of UL 60065 Cls 9 1 1 2 Inspect for access to live parts after removal of detachable parts Liv Parts UL 1492 Cls 18 1 UL 60950 1 Gls 2 1 1 1 Temperature Test UL 60065 Cls 7 Under normal operating conditions supporting surface and all accessible surfaces shall not attain excessive temperature rise as described in Table 3 UL 1492 Cls 68 Under normal operating conditions supporting surface and all accessible surfaces shall not attain excessive temperature rise as described in Table 68 1 UL 60950 1 Cls 4 5 Under normal operation maximum temperature allowable accessible surface Mod Accessible surfac
63. and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DHHS Marking Visual Check Product incorporated laser module shall contain statement 1 Complies with 21 CFR Chapter 1 Subchapter J 2 Complies with 21 CFR 1040 10 and 1040 11 Construction Check Visual Check No hazard when removing the packing 7 Parts Inventor Visual Check Shall meet label claims Technical information and related recommendations listed in this specification are proprietary information of Intertek
64. arp edges burrs fins moving parts and the like that may cause abrasion of insulation on conductors All soldering joints shall be mechanically secured before soldered 11 Mechanical Assembly Visual Check All mechanical parts shall be securely fixed and prevented from turning 12 Polarization Visual Check Switch fuse and other protective device shall be connected at ungrounded conductors The polarization of conductors at plug and receptacles shall be matched A cord connected appliance shall be provided with an appropriate type and length of flexible cord per section Electrical Safety ae cana Ae a re ae eee 14 Component Check Visual If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other without marking components 15 Dielectric Voltage UL 1363 2ed Cls 23 The insulation and spacings shall withstand the dielectric voltage Withstand Test withstand test without breakdown for a period of 1 min when a test voltage of 1250Vac is applied between a Live parts and accessible metal parts b Live parts of different polarity Parts protected against inadvertent contact with uninsulated live parts 17 Strain Relief UL 1363 Cls 30 2 The supply cord shall withstand for 1 min without displacement a direct pull of 35lbs Technical information and related recommendations listed in this specification are proprieta
65. ation with 24 9 IMERC may be required NH title x Chapter 149 M Sec 149 M 51 149 Product or packaging for items with button cells found to have M 57 intentionally added mercury that may be distributed to states CT Public Act 02 90 with Mercury legislation shall be Marked so as to be clearly NY Chap 145 Title 21 Ch visible prior to the sale and Product itself shall be marked 27 2101 2115 permanently for the life of the product with the following Battery Contains Mercury Do Not Putin Trash Recycle or Manage as Hazardous Waste or equivalent CT and NY further require that the product with button cell batteries that contain Hg to be replaceable Product with button cells found to have intentionally added mercury that may be distributed to CT or NY shall have the batteries replaceable allowing for use of common household tools ConstructionCheck ff 18 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Assembly _ turning points edges or moving parts 21 Mechanical Hazards UL 745 4 11 1 Edition Section 18 1 adequate protection against personal injury 22 Construction UL 745 4 11 1 Edition Tools which can be adjusted to different speeds shall be so Section 20 1 constructed that accidental changing of the setting is unlikely to occur if such a change might result
66. bited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA048 US Battery Operated Reciprocating Intertek Saw Jig and Sabre Saws Version 5 Date August 10 2011 Page 4 of 5 29 Heating UL 745 4 11 1 Edition Shall not attain excessive temperature under a no load condition Section 11 per section and table Cutouts and overload releases shall not operate during the test 30 Electric Strength UL 745 4 11 1 Edition Shall withstand a voltage of 500 V for 1 min without breakdown Section 15 Abnormal Operation UL 745 4 11 1 Edition Shall be designed to reduce the risk of fire as a result of Section 17 abnormal operation by subjecting the fully charged tool or battery pack to the open or shorting tests per this section 31 32 Motor Reversing UL 745 4 11 1 Switches or other devices for reversing motor direction shall Tests Section 17 4 withstand the stresses occurring when the direction of rotation is changed under running conditions with a fully charged battery per section for 25 times No mechanical or electrical failure shall occur 33 On Off Switch UL 745 4 11 1 Shall have adequate breaking capacity and be suitable for Tests Section 22 2 frequent operation
67. bly maintenance Instructions 5 General and UL 508 A general cautionary and warning marking intended to inform the user Cautionary of a potential risk of fire electrical shock or injury to persons shall be Markings provided Construction Cheek OOOOOCCCCCS 7 Parts Inventory Shall meet label claims 8 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 9 Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from turning Assembly edges or moving parts 11 Plug UL 508 The attachment plug of an appliance intended to be connected to a nominal 120 volt circuit shall be a polarized type The connections to the attachment plug shall be in accordance per section 1 Cord Type and UL 508 A cord connected appliance shall be provided with an appropriate type Length and length of flexible cord per section 2 Electrical Safety G O 3 13 Dielectric UL 508 An appliance shall be capable of withstanding for 1 min when a test Voltage voltage of 1000 VAC is applied between live parts and accessible metal Withstand Test parts without an indication of unacceptable performance 14 Accessibility of UL 508 An opening smaller than 1 inch 25 4 mm in an enclosure is acceptable Live Parts if a probe of standard when inserted point first into an opening cannot be made ot to
68. by the liquid involved and no liquid shall enter a compartment housing field installed wiring For a cord connected product rated 250 volts or less the leakage current is to be monitored during and after the test Mod Distilled water will be used for the test Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA040 US High Pressure Cleaning Machines Intertek Version 8 Date August 10 2011 Page 3 of 4 21 Grounding UL 1776 Cls 21 1 21 4 A product shall have provision for grounding The following are 21 5 acceptable means for grounding a For a product intended to be permanently connected by a metal enclosed wiring system a knockout or equivalent opening in the metal enclosure of the product b For a product intended to be permanently connected by a nonmetal enclosed wiring system such as nonmetallic sheathed cable an equipment grounding terminal or lead c For a cord connected product an equipment grounding conductor in the cord The surface of the insulation of a grounding conductor of a flexible
69. cal amp Energy DG EAO65 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California 31 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA049 US Portable Electric Sander Intertek Version 6 Date August 10 2011 Page 4 of 4 32 Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard VOC if applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time
70. cal items to California Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC if 8021B doc review applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional charge Testing Charge amp Sample Size amp Turnaround Time Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA022 US Electric Paper Shredder Version 7 Date August 10 2011 Page 3 of 3 Turnaround time 7 working day Sample size 2 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all electrical i
71. can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Bree IE ALTIAIL 10 Packing No hazard when removing the packing 11 Parts Inventory Shall meet label claims 12 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Assembly turning points edges or moving parts 15 Plug UL 60950 1 Cl The attachment plug shall have a current rating no lower than 3 2 1 125 of the current drawn by the apparatus under normal operating conditions and a voltage rating appropriate for the rated voltage for the apparatus Length 3 2 5 1 appropriate type and length of flexible cord per section ee Ne ee ee eee Electrical Safety Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of
72. cation report for verification For Power supply It is the vendor s responsibility to submit the certification report and compliance statement to DOE Rating UL 745 4 11 1 Edition The maximum rated voltage is 30 Vdc Section 5 1 5 6 7 Marking UL 745 4 11 1 Shall be marked with Section 7 1 rated voltage s in volts symbol for direct current manufacturer s name trade mark or identification mark manufacturer s model or type reference date of manufacture rated no load speed maximum cutting depth mm for cutting in wood jigsaw only Warning To reduce the risk of injury user must read and understand instruction manual The word Warning shall be in capital letters not less than 2 4 mm high and shall not be separated from the cautionary statement The statement shall be verbatim except the term Operator s manual or User guide may be used for the term instruction manual Marking UL 745 4 11 1 Edition When symbols are used they shall be per section Section 7 6 Section 7 10 the circuit to be controlled and has no other function This requirement does not apply to push buttons used for locking the mains switch This requirement refers to emergency off switches only and does not preclude the use of red trigger rocker toggle or other switches and controls For tools which might result in a risk of injury when started unexpectedly the off position of th
73. ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Construction Check SCS 8 Packing Visual Check No hazard when removing the packing 9 Parts Inventory Visual Check Shall meet label claims Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA027 US Clock Operated Switch Version 6 Date August 10 2011 Page 2 of 3 Test requirements Test Method Principle 10 Workmanship Visual Check Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from Assembly turning Internal Wiring Plug Cord Type and Length Polarization UL 917 Clause 17 UL 917 Clause 15 Visual Check Vis
74. cerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA016 US 12V Travel Mug Version 8 Date August 10 2011 Page 3 of 3 Acrylonitrile Copolymer 20g 3 pcs 9 WDs 320 Acrylic 80 in sq 9 WDs 335 P C Polycarbonate 60g 6 WDs 225 P E Polyethylene 10g 6 WDs 205 P P Polypropylene 10g 6 WDs 250 P S Polystyrene 5g 6 WDs 180 PVC Polyvinyl Chloride 10g 8 WDs 255 Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA017 US Relocatable Power Tap Version 7 Date August 10 2011 Intertek Page 1 of 3 Document Review ff 1 Labeling Packaging Uniform Labelling Distributor s name amp Address City State amp Zip shall be shown on or product Regulation the packaging pO Product Identification 2 Country of origin NAF
75. consecutive months Rated voltage Frequency Input in amperes volt amperes or watts For Indoor Use Only Caution or warning markings in English UL 60950 1 Cls 1 7 A general cautionary and warning marking intended to inform the user of a potential risk of fire electrical shock or injury to persons shall be provided Maker s or responsible vendor s name or trade mark model number other markings required by the standard 7 Cautionary Markings UL 1310 Cl 52 Cautionary markings where required shall be in letters no less than 1 8 high as required Dry location units shall be marked CAUTION and Risk of Electric Shock and the following or equivalent Dry location use only or Do not expose to liquids vapour or rain Battery Chargers shall be marked as required regarding the batteries that are to be charged Direct Plug in units shall be marked CAUTION Risk of Fire or Electric Shock Do not replace this plug assembly Other markings required per section UL 60950 1 Cls 1 7 A cautionary or warning marking intended to inform the user of a potential risk of fire electrical shock or injury to persons shall be provided 8 User Manual UL 1310 Cl 54 Instructions and warnings shall be provided in the user manual Important Safety UL 60950 1 Cls 1 7 identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regard
76. cord from being transmitted to terminals splices or interior wiring 24 Stability Test UL 60065 Cls Apparatus having a mass of 7 kg or more shall have adequate stability 19 1 During the tests the apparatus shall not overturn when inclined at an angle at 10 to the horizontal 25 Continuity of UL 60065 Cls The resistance of the connection between the PROTECTIVE EARTHING grounding 15 2 TERMINAL or contact and parts required to be connected thereto shall not connection exceed 0 1 ohm Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA059 US Video Game Console Intertek Version 5 Date August 10 2011 Page 3 of 4 Test requirements Reference Requirement Method AC Adaptor Operated Se 26 General and UL 1310 Charger shall be legibly and permanently marked Cautionary Cls 49 1 a The manufacturer s name trade name or trademark Markings b The date or other dating period of manufacture not exceeding any three consecutive months c Adistinctive catalogue or model number or the equivalent and d T
77. ctions within the converter or inverter disconnected All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Report relative ease of installation Report if instructions pertaining to installation are complete and understandable Parts shall be provided as claimed When used with specific product under maximum loading condition for 4 hours the following shall not occur Function failure Emission of flame Molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure Shall meet the requirements in DG EA065 e All products containing CA Prop 65 warning label will be reported as FAILED Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Product with solvent based liquid eg Adhesive paints glues and etc shall not contain toxic aromatic compounds and hazard substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Turnaround time 7 working day Sample size 3 pieces Technical information and related recommendations listed in this specification are proprietary information of Int
78. d liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC if 8021B doc review applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA022 US Electric Paper Shredder Intertek Version 7 Date August 10 2011 Page 1 of 3 Document Review 1 Labelling Uniform Packaging Distributor s Name am
79. e Compliance with this specification does not of itself confer immunity from legal obligations Wireways shall not allow wires to come in contact with sharp points edges or moving parts Product Spec DG EA059 US Video Game Console Intertek Version 5 Date August 10 2011 Page 2 of 4 Test requirements Reference Requirement Method 11 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Ease of Follow directions Report relative ease of installation Report if instructions pertaining to Installation for installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed Ease of Cleaning Follow Follow the cleaning instruction Removable parts shall be replace easily Instructions or and not causing any safety hazards Wipe Gently with Damp Cloth AC Operated Product Document Review E 14 Safety Visual Check The provided UL or ETL Listing safety mark shall be validated Certification Mark 15 General and UL 60065 Cls 5 A general cautionary and warning marking intended to inform the user of a Cautionary potential risk of fire electrical shock or injury to persons shall be provided Markings 16 User Manual UL 60065 Cls 5 4 Instructions and warn
80. e Dielectric Voltage Withstand Test UL 817 and the Leakage Current Test Section 18 17 Dielectric Voltage UL 817 Cls 88 The Sample shall be capable of withstanding without breakdown Withstand Test for a period of 1 minute the application of a 60 Hz potential of 1250 V between any two conductors 18 Temperature Test UL 2438 Cls 36 The temperature rise of an outlet measured at the points Mod described in 36 2 shall not be more than 30 54F when the device is carrying its maximum rated current One sample as received condition prior to test temperatures are to be measured by means of thermocouples attached to the wiring terminals or cord connections Mod 1 sample as received condition 19 Strain Relief Test UL 2438 Cls 23 The assembly of the cord to a fitting shall be capable of withstanding a straight pull of 30 lbf 1383N applied between the fitting and the cord A pull exerted on a cord shall not be transmitted directly to the terminals of a fitting 20 Retention of Plugs UL 2438 Cls 34 The sample subjected to ten conditioning cycles of insertion and Tests withdrawal of a standard solid blade attachment plug The mating plugs are to have a 1 15P configuration A pull of 3 Ibf 13 N ina direction perpendicular to the plane of the face of the cord connector and tending to withdraw the plug from the device is then to be applied to the plug for 1 minute The displacement of the plug shall not be greater than 0 079 inch 2 mm
81. e appliance is installed Manufacturer s name trademark etc Model number type reference etc The input voltage frequency and amperes or watt The words Provided with integral protection against overloads Output voltage and current Date code Other markings required per section 5 Cautionary Markings UL 458 Cls 57 A cautionary or warning marking intended to inform the user of a potential risk of fire electrical shock or injury to persons shall be provided 6 Manual Important UL 458 Cls 58 Instructions and warnings shall be provided in manual that warns Safety Instructions the user against reasonable foreseeable uses or misuses of the product It shall also include instructions regarding installation use safety and maintenance Parts Inventor Shall meet label claims ConstructionCheck ff 7 8 Packing No hazard when removing the packing 9 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label turning points edges or moving parts 12 Accessibility of Live UL 458 Cls 8 1 1 An uninsulated live part film coated wire or moving part that Parts could result in a risk of electric shock or injury to persons shall be located or enclosed so that unintentional contact is precluded 13 Power Cord UL 458 Cls 11 2 The product shall may employ Type S SE SEOO SO ST STO SJ
82. e dealer or an experienced radio TV technician for help Mark directory with the sample s listing number and model number 6 Markings UL 458 Edition The following markings shall be legible and readily visible during Section 52 1 52 2 4 use Manufacturer s name trademark or etc Model number type reference or etc Electric rating Date Code A battery operated portable tool provided with a user replaceable battery or battery pack shall be marked For Use Only With____ Charger or the equivalent The charger may be identified by a catalog number a series number or the equivalent Other markings required by standard 7 Labeling Product Visual Type Size of battery Permanent On Product Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA046 US Cordless Multi Tools Version 5 Date August 10 2011 Page 2 of 4 Test requirements Reference Method Number and type of batteries required 8 Labeling Product Permanent On Product 9 Labeling Product Permanent On P
83. e dropped free fall 3 times in succession from a height of 1m onto a hardwood surface After test the unit shall pass dielectric voltage withstand test Safety Electrical Safety Safety Safety Review Page 3 of 4 ZN MODERN TESTING SERVICES TEST PROTOCOL MTS DOLLAR GENERAL AC ADAPTOR EL 91310 US V1 MTS Report Number Date Fitness for Use Packaging Review Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Follow directions for F M na Fitness for Use Packaging Review Ease of Installation installation in Inatruation Report relative ease of installation Report if instructions pertaining to installation are complete and understandable a Parts shall be provided as claimed manual Fitness for Use NotApplicable Range of Operation In house method __ The unit should operate within the voltage range of 106 127 volts SSS O O When used with specific product under maximum loading condition for 4 hours the following shall not occur Function failure Fitness for Use Not Applicable Continuous Operation Actual use Emission of flame Molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the
84. e mains switch shall be indicated unless this position is obvious the indication If required shall be the figure 0 The figure 0 shall not be used for any other indication This requirement does not preclude the use of the figure 0 for the minimum setting of a variable speed control 0 degree 0 depth of cut or similar indication 8 Marking UL 745 4 11 1 Edition A push button shall be colored red only if it serves to open Section 7 13 the country in which the tool is to be sold Section 7 14 section Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA048 US Battery Operated Reciprocating Intertek Saw Jig and Sabre Saws Version 5 Date August 10 2011 Page 2 of 5 11 Instructions UL 745 4 11 1 Edition An instruction manual shall be provided with a tool and Section 31 1 packaged such that it is obvious when tool is removed from the carton General and specific safety instructions required by this standard shall be written in the official language s of the country in which the tool is to be sold See
85. e no evidence of cracking aaa er ca eT Fitness for Use aes 17 Durability of Clamps 18 Effects of Extreme Temperature Change In House Method In House Method The insulated clamp is to be subjected to 100 cycles of opening the jaws to the maximum opening position followed by releasing the handles to the at rest position No damage shall be observed after test No change failure after 24 hours each of 0 F and 122 F Additional test E BE EE E Z F Z 19 Chemical amp Energy Efficiency test for all electrical items to California Dollar General DG EA065 Shall meet the requirements in DG EA065 e All products containing CA Prop 65 warning label will be reported as FAILED Certificate of Compliance Toxics in packaging Volatile organic Substances VOC if applicable Client requirement GC MS screening US EPA method 5000 and 8021B doc review Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Product with solvent based liquid eg Adhesive paints glues and etc shall not contain toxic aromatic compounds and hazard substances Additional Charge Item GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 Testing Charge amp Sample Size amp Turnaround Time Turnaround time Sample size 7 working da 3 pieces Testing charge
86. echanical stress on a flexible cord from being transmitted to terminals splices or interior wiring 22 Power In house method If AC adaptor used power consumption of the product shall not consumption exceed power output of the AC adaptor 23 Battery reverse UL 60950 1 Cl Insert battery but with reverse polarity and stabilize for 1 hour polarity 4 3 8 Explosion or chemical leakage shall not occur 24 Battery UL 60950 1 Cl overcharge test 4 3 8 25 Battery short UL 60950 1 Cl circuit test 4 3 8 26 Leakage current UL 60950 1 Cl 5 1 For product with rechargeable battery full charged battery installed and charge for additional 7 hours explosion or chemical leakage shall not occur For product with rechargeable battery full charge battery installed and short circuiting any voltage limiting components in the load circuit of the battery unit test explosion or chemical leakage shall not occur The leakage current of unit shall be below limits required Hand held product less than 0 75mA All other product less than 0 25mA Fitness for Use T 27 Functional Actual Use Check 28 Ease of Actual Use Installation 29 Ease of Actual use Cleaning All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Follow directions for installation in I
87. eck __ Construction Check 5 Packing Visual Check No hazard when removing the packing 6 Workmanship Visual Check Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label All mechanical parts shall be securely fixed and prevented from turning Assembly Wireways shall not allow wires to come in contact with sharp points edges or moving parts Fitness for Use TAa Zali E A TFA 9 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 10 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be replaced Wipe Gently with easily and not causing any safety hazards Damp Cloth Requirement for Special Features Wireless Product 11 FCC part 15 rules Visual Check FCC part 15 certificate and report shall be provided for verification 12 FCC Part 15 Visual Check Marking shall include marking and FCCID instruction Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found
88. ection to the branch circuit shall be Section 12 2 1 of the polarized or grounding type The length of cord external to the unit and including the attachment plug shall not be less than 6 ft 1 8 m as measured from the face of the attachment plug to the point of attachment or entry Section 12 1 Must withstand a 35 Ib strain I8 AWG cord or higher and 20 Ib Section 41 3 amp 41 for less than 18 AWG for 1 minute 32 Surface Std Measure Under no load condition 150 F max for handles amp controls Temperature 185 F max for housing 33 Drop Impact In house method Withstand three 3 ft drop to vinyl clad cement with no failure Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA046 US Cordless Multi Tools Intertek Version 5 Date August 10 2011 Page 4 of 4 Fitness for Use 34 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendlines
89. ective devices shall be Devices Section 9 rated no more than 8 A for 12 V systems or 4 A for 24 V systems Protective devices not within the cigarette lighter connector shall be no more than 5 away by the conductor Protective devices shall otherwise be per section Construction Check _ as Electrical Safety 17 Component Visual If listing safety report available report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 18 Dielectric Voltage UL 2089 While in use temperature shall withstand 1000 2 x rated voltage ac Withstand Test Section 25 hipot test Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA016 US 2VT IM Intertek Gains oe Date August 10 2011 Page 2 of 3 Test Items Test Method Test Requirements Section 28 20 Temperature Test UL 2089 When tested with rated load maximum temperature rise allowable Section 24 1 accessible surface Mod Accessible surfaces only
90. ed For wired product FCC part 15 verification report shall be provided if the operating frequency gt 9kHz for AC or operating frequency gt 1 705Hz for Battery operated product FCC Part 15 Visual Check Marking shall include marking and FCC part 15V Model number instruction FCC part 15V This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC part 15C FCC ID Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be d
91. ed from 1 meter onto a hard wooden surface for 3 times 15 With Child Appealing DG EA051 Shall meet the requirements in DG EA051 Features 16 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA056 US Audio Video USB Cables Intertek Version 3 Date 18 March 2010 Page 2 of 2 Sample size 3 sets for DG EA056 US 12 sets for DG EA051 US Document required 1 Packaging or Packaging Artwork 2 User manual 3 Markings including rating label warning and caution markings 4 Safety certificate and report Turnaround time 7 working days Test charge 150USD 80 USD for DG EA051 US exclude chemical test Lead Content of Paints or Similar Surface Coating 25USD per coating Lead Content of Substrate Materials 25USD per coating California Phthalates Content Requirement 150USD for 6 chemica
92. ed without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA033 US AC Adaptor Intertek Version 9 Date August 10 2011 Page 3 of 4 Test requirements Test Method UL 60950 1 Cls 4 2 6 A sample is to be dropped free fall 3 times in succession from a height of 1m onto a hardwood surface After test the unit shall pass dielectric voltage withstand test Fitness for Use ESE eee eee 25 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 26 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 27 Range of Operation In house method The unit should operate within the voltage range of 106 127 volts 28 Continuous Operation Actual use When used with specific product under maximum loading condition for 4 hours the following shall not occur Function failure Emission of flame Molten metal
93. eeling of rating or caution warning label turning Wireways shall not allow wires to come in contact with sharp points edges or moving parts Fitness for Use E EE 13 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems System according to the claimed information amp Usage installation Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA058 US Digital Photo Key Chain Intertek Version 5 Date Aug 16 2011 Page 2 of 2 16 Continuous Operation In house method Set the unit to normal operation continuously operate for 2 Test hours Shall not indicate safety issue fire risk or any other abnormality eee eee Antivirus program It shall be virus free operations As specified by manufacturer shown on manual label within 3 tolerance 20 Built in Memory Visual Check As specified by
94. egC only and sample size to 1 During and after test the battery shall not explode or catch fire or chemical leaks Temperature of battery pack casing shall not exceed 150 degC aditionagfest A IN E E EEE WE NE FF FF A FC 35 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA053 US Headphone Earphone and Loudspeaker Intertek Version 1 2 Date 18 March 2010 Page 4 of 4 Sample size 3 samples Turnaround time 7 working days Test charge No separate power source 100 USD Battery operated 150 USD AC mains or AC adaptor operated 250 USD For additional charge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark 1 Additional samples and tests may be necessary subjected to
95. egal obligations Product Spec DG EA007 US Audio and Video Products Version 13 Date August 10 2011 Page 3 of 6 23 Interface method In house Method As specified by manufacturer shown on manual label e g USB or Firewire if applicable Battery Charge In house Method Measure the average current of record mode Calculate the battery life Life if applicable by the formula rated battery capacity average record current Measure the average current of playback mode Calculate the battery life by the formula rated battery capacity average playback current AC Operated Product Document Review o 25 Safety Visual Check The provided UL or ETL Listing safety mark shall be validated Certification Mark 26 General and A general cautionary and warning marking intended to inform the user Cautionary of a potential risk of fire electrical shock or injury to persons shall be Markings provided 27 User Manual UL 60065 Cls 5 4 Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the product It Instructions UL 1492 Cls 130 132 shall also include instructions regarding the installation use safety and Assembly maintenance Instructions UL 60950 1 Cls 1 7 Construction Check 28 Plug Visual Check Plug shall be 3 wire grounding type or 2 wire polarized attachment plug 29 Cord Type and UL 60065 Cls 16 A cord connected appli
96. end terminal or receptacle of the N connector e using a digital multimeter Fitness for Use 21 Functionality aano Use ESTERS SSE check if the product is able to operate as intended according to the Check instruction manual 22 Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 23 Ease of Follow Instructions or Follow the cleaning instruction Removable parts shall be replace easily Cleaning Wipe Gently with and not causing any safety hazards Damp Cloth 24 Continuous Actual use Under maximum loading condition for 4 hours the following shall not Operation Test occur Emission of flame molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure Additional test 25 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy e All products containing CA Prop 65 warning label will be reported as Efficiency test FAILED for all electrical items to California 26 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent base
97. ended to be fastened in place or located in a designated space and employing a standard attachment plug rated 20 amperes or less The connections of the attached flexible cord within the appliance are to be disconnected A 35 pound 15 9 kg weight is to be suspended on the cord and supported by the product so that the strain relief means will be stressed for 1 minute from any angle that the construction of the product permits At the point of disconnection of the conductors there shall be no movement of the cord as to indicate that stress would have resulted on the connections A During the temperature test the temperature of a surface that may be contacted by the user shall not rise more Handle or knob grasped for lifting carrying or holding A Metallic 250 45 F B Nonmetallic 35 C 63F Handle knob or surface of the enclosure intended to be contacted during normal use but not requiring continuous holding A Metallic 35C 63F B Nonmetallic 60C 108 F Surface subjected to casual contact A Metallic 45C 81F B Nonmetallic 70 126 F For a product with a reservoir or liquid storage chamber that can be filled to overflowing the reservoir is to be filled to overflowing with distilled water Additional distilled water equal to 10 percent of the capacity but not more than 1 quart is then to be poured into the reservoir The sample shall be no wetting of live parts film coated wire or insulation likely to be adversely affected
98. eral Toxics in Packaging Certificate of Compliance Client requirement Shall have no sharp points edges other than those required for function Mod expanded scope to other products Report overall dimensions shall meet label claims If applicable 0 5 Report overall weight shall meet label claims If applicable 0 5 BV Lab Number Technician Name Test Date Reviewed By Date Page 2 of 5 BV Lab Number Technician Name Test Date Reviewed By Date Page 3 of 5 DGEN 04255 US UNIVERSAL REMOTE CONTROL BATTERY OPERATED V11 Shall have no discernible surface degradation including crazing shivering denting bubbles cracks Defects CPSD HL 01057 A stains deformations chips fractures heavy lines MTHD Visual waves shear marks scratches scuff marks A indentations or blisters Il a CPSD HL 01057 nel no components missing malformed and or efects MTHD Visual ractured 1 1 PERFORMANCE 01039 MTHD materials used etc Report any features not evaluated CPSD HL 01058 Report the claimed operation range Shall be function Operational Range at claimed range If no claim the device shall be MTHD Actual use function at distance of 5 m m CPSD HL 01058 Buttons shall withstand 100 cycles of use Drop Test CPSD EL 01032 1 3 drops from 1 meter on hardwood flooring Report P MTHD discrepancies and drop number Not already covered by other tests Functionalit a A
99. erforming an operation where the cutting tool may contact hidden wiring Contact with a live wire will also make exposed metal parts of the tool live and shock the operator i ee ed Visual Check Visual Check 2 1 Workmanship Visual Check Shall have no major defects such as external Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label internal Components shall be reliably mounted on PCB or other proper fixing 11 Internal Wires Visual Check Wireways shall be smooth and entirely free from sharp edges burrs fins moving parts and the like that may cause abrasion of insulation on conductors All soldering joints shall be mechanically secured before soldered Assembly Live Parts protected against inadvertent contact with uninsulated live parts Visual Check Switch fuse and other protective device shall be connected at ungrounded conductors The polarization of conductors at plug and receptacles shall be matched UL 745 4 1 Chuck keys shall be so designed that they drop easily out of position Cls 18 when released they shall not be fixed to the tool by means of a chain string or similar means 16 Switches UL 745 4 1 Switches shall be so located that accidental operation is unlikely to Cls 20 occur Compliance is checked by inspection and by a test consisting of placing the tool in any possible position on a horizontal surface Inadvertent opera
100. ertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA062 US Power Inverter Version 5 Date August 10 2011 Page 3 of 3 Testing charge Sample size Basic charge USD 200 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations BV Lab Number Technician Name Test Date Reviewed By Date Page 1 of 6 DOLLAR GENERAL CORPORATION TEST PROTOCOL FOR DGEN 04034 US WIRELESS HEADPHONE V11 Sam
101. es Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA026 US Current Taps and Adapters Version 7 Date August 10 2011 Page 2 of 2 Test requirements Test Method Principle 18 Ease of Installation Follow directions for installation in Instruction manual 19 Ease of Cleaning Follow Instructions or Wipe Gently with Damp Cloth 20 Continuous Actual use Operation Test 21 Chemical amp Energy Efficiency test for all electrical items to California DG EA065 22 Dollar General Certificate of Compliance Toxics in packaging Volatile organic Substances VOC if applicable Additional Charge Item Client requirement GC MS screening US EPA method 5000 and 8021B doc review Testing Charge amp Sample Size amp Turnaround Time Report relative ease of installation Report if instructions pertaining to installation are complete and understandable Parts shall be provided as claimed Follow the cleaning instruction Removable parts shall be replaced easily and not causing any safety hazards Under maximum loading condition for 4 hours the following shall not occur Emission of flame molten metal
102. es only shall not exceed temperatures specified Protective devices shall not operate Handles knobs continuously held 55 degC Metal 75 degC Plastic Handles knobs touched for short period 60 degC Metal 85 degC Plastic External surface 70 degC Metal 34 Strain Relief Strain relief shall be provided to prevent a mechanical stress on a flexible cord from being transmitted to terminals splices or interior wiring Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA007 US Audio and Video Products Version 13 Date August 10 2011 Page 4 of 6 Test Item Test Method 35 Stability Test UL 60065 Cls 19 1 Apparatus having a mass of 7 kg or more shall have adequate stability During the tests the apparatus shall not overturn when inclined at an angle at 10 to the horizontal 36 Continuity of UL 60065 Cls 15 2 The resistance of the connection between the PROTECTIVE grounding EARTHING TERMINAL or contact and parts required to be connected connection thereto shall not exceed 0 1 ohm UL 60950 1 Cls 2
103. essary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA022 US Electric Paper Shredder Intertek Version 7 Date August 10 2011 Page 2 of 3 16 Accessibility of UL 60950 1 An opening smaller than 1 inch 25 4 mm in an enclosure is acceptable Live Parts Clause 2 1 1 1 if a probe as illlustrated in the standard when inserted point first into an opening cannot be made ot touch any uninsulated live part or film coated wire 17 Temperature Test UL 60950 1 Under normal operating conditions supporting surface and all Clause 4 5 1 accessible surfaces shall not attain excessive temperature as described in the standard Handles and knobs 60 C metal 85 C plastic External surfaces 70 C metal 18 Strain Relief UL 60950 1 Strain relief shall be provided to prevent a mechanical stress on a flexible cord from being transmitted to terminals splices or interior wiring 19 Stability Test UL 60950 1 The appliance is to be placed on a horizontal support and tilted in the most unfavorable direction through an angle per section The results are considered to be acceptable if the appliance does not overturn 20 Continuity of UL 60950 1 The resistance between the point of connection of the equipment grounding grounding means at or within the appliance and any other point in the connectio
104. est UL 1449 Cls 51 2 One unit to be subjected to the impact that results from its being dropped three times a series through a distance of 0 91 m 3 feet from the bottom of the TVSS to strike a concrete surface in the positions most likely to produce adverse results After subjected the test the sample shall not a Creation of any openings in the enclosure that results in accessibility of live parts when judged in accordance with Accessibility of Live Parts Section 13 b Any condition that might affect the safe mechanical performance of the TVSS c Any other condition that increases the risk of electric shock Fitness for Use y eee 19 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 20 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 21 Continuous Operation Actual use When used with specific product under maximum loading condition for 4 hours the following shall not occur Function failure Emission of flame Molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibilit
105. etermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DHHS Marking Visual Check Product incorporated laser module shall contain statement 1 Complies with 21 CFR Chapter 1 Subchapter J 2 Complies with 21 CFR 1040 10 and 1040 11 Physical _ Parts Inventor Visual Check Construction Check 5 6 Shall meet label claims 7 Packing Visual Check No hazard when removing the packing 8 1 Workmanship Visual Check Shall have no major defects such as Cracks or breakage Serious scratches on the external surface Peeling of rating or caution warning label 9 Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from turning Assembly 0 Internal Wiring Visual Check Fitness for Use Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its us
106. ety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA061 US Booster Cable Version 5 Date August 10 2011 Page 2 of 2 Reference Method 13 Dielectric Strength Test on cable Dielectric Strength Test on clamp Secureness Cold Impact Test UL 1839 Cls 4 8 The cable is to be wrapped in foil and a 500 volt 60 Hz potential applied between the conductors and the foil and also between the two conductors The test voltage is to be applied for 1 minute There shall be no evidence of breakdown of insulation UL 1839 Cls 5 7 The cable is to be wrapped in foil and a 500 volt 60 Hz potential applied between the conductors and the foil and also between the two conductors The test voltage is to be applied for 1 minute There shall be no evidence of breakdown of insulation UL 1839 Cls 5 8 1 5 Each end of the cable connected or joined to the clamp assembly is be able to withstand a tensile force of 445 N 100 Ibs applied along an axial direction to the interface between the cable clamp and the conductor without separating UL 1839 Cls 4 10 Samples are to be subjected to a temperature of minus 25T 2T minus 13F 4F for 4 hours The cable is th en to be impacted by a 2 27 kg 5 Ib weight dropped from a height of 610 mm 2 ft The samples are to be checked for signs of cracking There shall b
107. f Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA007 US Audio and Video Products Version 13 Date August 10 2011 Page 6 of 6 Test Item Test Method 45 Impact Test UL 1310 Cls 46 2 A sample is to be dropped free fall 3 times in succession from a height of 3 feet onto a hardwood surface After test the unit shall pass dielectric voltage withstand test UL 60950 1 A sample is to be dropped free fall 3 times in succession from a height Cls 4 2 6 of 1m onto a hardwood surface After test the unit shall pass dielectric voltage withstand test UL60065 5 A sample is to be dropped free fall 3 times in succession from a height Cls 12 1 4 of 1m onto a hardwood surface After test the unit shall pass dielectric voltage withstand test Battery operated S Battery operated Electrical Safet polarit or chemical leakage shall not occur overcharge test explosion or chemical leakage shall not occur 48 Battery short UL 60065 For rechargeable battery with full charge battery installed and short circuit test CI 14 10 1 circuiting the positive and negative terminals of the battery with a Modify with test temp resistor of 0 1 ohm max at 20 degC only and sample size to 1 During and afte
108. fter the test or the measured temperature rise exceeded the limit Remark PPR Pre Production Review VT Verification Test Key BV Lab Number Technician Name Test Date Reviewed By Date Page 6 of 6 Additional Charge For This Test Tk Mandatory Requirement By Request Only Result Key C Claimed R Recorded M Meets NM Does Not Meet NA Not Applicable NT Not Tested Rating Key Incomplete INCOMPLETE PPT Rating Only Complete PPT COMPLETE Rating Only GOOD Good UNSAT Unsatisfactory No Of Samples Required for Complete Testing Client Approval APRIL 02 2012 No Of Fully Packed Cartons For Transit Testing A Chuck Rogers No Of Working Days For Complete Testing Creanon Date MAY 09 2008 Last Revision Date NOVEMBER 18 2011 Pricing Review Date Technical Review Date BV Lab Number Technician Name Test Date Reviewed By Date Page 1 of 5 DOLLAR GENERAL CORPORATION TEST PROTOCOL FOR DGEN 04255 US UNIVERSAL REMOTE CONTROL BATTERY OPERATED V11 Samples SUPPLEMENTAL PROTOCOLS Note Additional cost sample size and TAT may be required if testing to 1 or more supplemental protocols is necessary Please refer to the below referenced supplemental protocol s for additional information Electronic products shall have complied with FCC Industry Canada regulations appropriate for the country of destination as shown by evaluation to the cited protocol Products under FCC Verification or
109. g If imported Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and model number 4 Marking General UL 2438 Cls 42 The following markings shall be legible and readily visible marked on a tag or label Electrical Ratings in amps volts and watts For temporary outdoor installation and use Not to exceed 90 days or equivalent wording This marking shall be in letters having a minimum height of 1 16 inch 1 6 mm Use only with a fuse rated 15 Amps 125 Volts on the surface ofthe fused plug Other markings specified in standard 5 Packaging Markings UL 2438 Cls 43 The sample shall contain all of the following or equivalent and Instructions statements following the word CAUTION on the outer surface of the smallest unit package or on a stuffer sheet or tag or its equivalent a CAUTION Risk of Fire Not for permanent installation Use only with outdoor equipment Christmas tree or other seasonal decorative lighting products having a total of 12 Ampere maximum Do not install or use this product for more than a 90 day period b If using Christmas tree or decorative lighting products that are not marked with an ampere rating connect no more than 140 screw base lamps C7 or C9 or 12 strings with midget push in lamps to this cord set c Cord sets shall be plugged into a GFCl protected receptacle d If using an outdoor use cord
110. ge Documentation Strain Relief Power supply cord shall withstand the following pull force for 25 times 1 second each Electrical Safety Review UL 60950 1 Cls 3 2 6 Mass of equipment kg lt 1 30 N 1 lt Mass of equipment kg lt 4 60 N Mass of equipment kq gt 4 100 N Documentation UL 1310 Cl 33 Surface temperature of any accessible surface should not exceed a temperature rise of more than 90 F 50 C Temperature Test z Review P oe a 1 Cls 4 5 Maximum temperature shall not exceed limits specified in Table 4B part 2 Modified accessible parts Continuity of All exposed dead metal parts that are exposed to contact during any servicing operation including maintenance and repair Not Applicable Grounding In house method and that can become energized shall be electrically connected to the grounding terminal and with earth resistance not more Connection than 0 1 Ohm A Direct Plug In Blade E Each blade and the grounding pin if provided shall withstand a direct pull of 20 Ibf 89 N for 2 minutes without loosening The Not Applicable Secureness Test Ini housem thod two blades tested together shall also withstand a direct pull of 20 Ibs for 2 minutes without loosening UL 1310 CIs 46 2 A sample is to be dropped free fall 3 times in succession from a height of 3 feet onto a hardwood surface Documentation Impact Test rasa After test the unit shall pass dielectric voltage withstand test UL 60950 1 Cls 4 2 6 A sample is to b
111. ge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA012 US Rechargeable Screwdriver Version 7 Date August 10 2011 Page 1 of 4 Test Item Test Method een _ Se Document Review Labelling Uniform Packaging Packaging or and Labelling product Regulations Distributor s name amp Address City State amp Zip shall be shown on the packaging Po i i i Product Identification Country of origin e amp FTCA Sect Shall mark with Country Of Origin If Imported Mercury TST Rechargeable Containing and Battery Recycling Act Rechargeable Visual if applicable Battery Management Act Pub L 104 142 13 May 1996 Stat 110 1333 4 Safety Visual Check Certification Mark DOE
112. geable and II for Batteries of button cell size are allowed small amounts of added mercury containing mercury but shall test to less than 25 mg Hg cell Testing is battery required on all included alkaline manganese batteries zinc carbon Heavy Duty batteries and silver oxide and zinc air button cells Perform test only if no related document provided for review Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA048 US Battery Operated Reciprocating Intertek Saw Jig and Sabre Saws Version 5 Date August 10 2011 Page 3 of 5 Mercury Labeling as Various State Laws If a button cell is found to have intentionally added mercury applicable to Button including such as by testing at over 1 ppm RI CT NY and VT require Cell Battery VT Title 10 Chapter 159 product containing mercury have labeling to indicate the powered devices Sec 6621d presence of mercury and instructions on how to properly dispose If Applicable RI Title 23 Chapter 23 of the product Requirements vary by state Registr
113. gin NAFTA amp FTCA Sect 5 Country Of Origin If Imported imported 3 Safety Certification The provided UL or ETL Listing safety mark shall be validated Mark 4 General and UL 498A A general cautionary and warning marking intended to inform Cautionary the user of a potential risk of fire electrical shock or injury to Markings persons shall be provided User Manual UL 498A Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regarding the Assembly installation use safety and maintenance Instructions ConstructionCheck 6 Packing Visual Check No hazard when removing the packing 7 Parts Inventory Visual Check Shall meet label claims 8 Workmanship Visual Check Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Assembly turning points edges or moving parts Electrical Safety os fF FNP TUT 12 11 Plug Visual Check The attachment plug of the power supply cord of an appliance intended to be connected to a nominal 120V circuit and provided with a 15 or 20 ampere general use receptacle shall be of the 3 a ob wire grounding type E 2 Dielectric Voltage UL 498A An appliance shall be capable of withstanding for 1 min when a Withstand Test test vol
114. he electrical rating UL 1310 Charger shall be marked with one of the following Cls 49 4 a Class 2 BATTERY Charger b Class 2 TRANSFORMER c Class 2 Power Supply or d Class 2 Power Unit DOE requirement 10 CFR 430 Shall have valid DOE certification report for verification It is the vendor s responsibility to submit the certification report and compliance statement to DOE 28 Output current UL 1310 The maximum output current shall not exceed the value specified in Table and power test Cls 28 2 28 1 and the maximum output volt amperes shall not be more than 100 Inherently Limited volt amperes except as indicated in 28 2 3 and 28 3 1 29 Output current UL 1310 When the unit includes means to automatically de energize the output and power test Cls 28 3 circuit the values of the output current and volt amperes shall not exceed Inherently Limited those specified in Table 28 2 30 Dielectric UL 1310 Shall withstand for 1 minute without breakdown Withstand Cls 32 a One thousand volts AC plus twice the maximum rated voltage between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b One thousand volts AC plus two times the sum of secondary voltages between secondary windings for units described in 26 3 or 28 2 3 c Five hundred volts AC between a secondary circuit and dead metal parts d A DC potential of 1 414 times 2 V 1 000 where V is the
115. heny in DG EA051 Features 22 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California 23 Dollar General Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Client requirement Sample size 3 sets for DG EA057 US 12 sets for DG EA051 US Document required 1 Packaging or Packaging Artwork 2 User manual 3 Markings including rating label warning and caution markings 4 Safety certificate and report Turnaround time 7 working days Test charge 150USD 80 USD for DG EA051 US exclude chemical test Lead Content of Paints or Similar Surface Coating 25USD per coating Lead Content of Substrate Materials 25USD per coating California Phthalates Content Requirement 150USD for 6 chemicals 120USD for 3 chemicals According to DG s requirement phthalates test would apply to this electrical item For additional charge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed
116. hine Caller ID Intertek Version 9 Date Aug 16 2011 Page 1 of 3 Document Review T SO 1 Labeling Uniform package and Distributors Name amp Address City State amp Zip Packaging or labeling regulations product 2 Country of origin NAFTA amp Country Of Origin If Imported FTCA Sect 5 3 Safety Visual Shall have valid UL or ETL listing Verify listing by NRTL product Certification Mark directory with the sample s listing number and model number 4 General and UL 60950 1 Cl 1 7 A general cautionary and warning marking intended to inform the user Cautionary of a potential risk of fire electrical shock or injury to persons shall be Markings provided Maing shall contain at least Manufacturer s name or trade mark or identification mark Manufacturer s model or type reference Rated voltage for AC product Rated frequency for AC product Rated current for AC product Class Il symbol for class Il equipment onl 5 User Manual UL 60950 1 Cl 1 7 2 jnatuctons and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assembly maintenance Instructions For product provided with AC adaptor the instruction shall state that the socket outlet shall be installed near the equipment and shall be easily accessible 7 FCC Part 68 Visual Marking sh
117. ht of 1 meter 22 Power Draw Current meter If the product can be driven by an AC adaptor measure DC current draw under normal use condition at nominal voltage Current draw by product shall not exceed rated output of the adaptor 23 Heating UL 745 3 Accessible surface of the tool shall not attain excessive temperature cls 11 under a no load conditions per Section and Table Cutouts and overload releases shall not operate during the test Battery Charger Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA012 US Rechargeable Screwdriver Intertek Version 7 Date August 10 2011 Page 3 of 4 Test Item Test Method 24 Output current UL 1310 The maximum output current shall not exceed the value specified in and power test Cls 28 2 Table 28 1 and the maximum output volt amperes shall not be more than Inherently Limited 100 volt amperes except as indicated in 28 2 3 and 28 3 1 25 Output current UL 1310 When the unit includes means to automatically de energize the output and power test Cls 28 3 circuit
118. ical rating UL 1310 Charger shall be marked with one of the following Cls 49 4 a Class 2 BATTERY Charger b Class 2 TRANSFORMER c Class 2 Power Supply or d Class 2 Power Unit Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA053 US Headphone Earphone and Loudspeaker Intertek Version 1 2 Date 18 March 2010 Page 3 of 4 Electrical Safety 26 Output current UL 1310 The maximum output current shall not exceed the value specified in and power test Cls 28 2 Table 28 1 and the maximum output volt amperes shall not be more Inherently Limited than 100 volt amperes except as indicated in 28 2 3 and 28 3 1 27 Output current UL 1310 When the unit includes means to automatically de energize the output and power test Cls 28 3 circuit the values of the output current and volt amperes shall not Inherently Limited exceed those specified in Table 28 2 28 Dielectric UL 1310 Shall withstand for 1 minute without breakdown Withstand Cls 32 a One thousand volts AC plus twice the
119. igations Product Spec DG EA053 US Headphone Earphone and Loudspeaker Intertek Version 1 2 Date 18 March 2010 Page 2 of 4 AC Operated Product Document Review ff 13 Safety Visual Check The provided UL or ETL Listing safety mark shall be validated Certification Mark 14 General and UL 60065 Cls 5 A general cautionary and warning marking intended to inform the user Cautionary of a potential risk of fire electrical shock or injury to persons shall be Markings provided 15 User Manual UL 60065 Cls 5 4 Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assembly maintenance Instructions Construction Check lt 16 Plug Visual Check Plug shall be 3 wire grounding type or 2 wire polarized attachment plug 17 Cord Type and UL 60065 Cls 16 A cord connected appliance shall be provided with an appropriate type Length and length of flexible cord per section Electrical Safety 18 Component Visual Check If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 19 Dielectric Voltage UL 60065 Cls 10 3 An appliance shall be capable of withstanding for 1 min whe
120. igations Product Spec DG EA013 US 12V Power Light Spot Light Intertek Version 7 Date August 10 2011 Page 1 of 2 Document Review yy Labelling Uniform Packaging Distributor s name amp Address City State amp Zip shall be shown on the Packaging or and Labeling packaging product Regulations Product Identification 5 indicated to the ultimate purchaser of a product where it is made 3 General and UL 2089 Battery chargers shall be marked CAUTION and following or Cautionary Section 29 equivalent Charge only __ type rechargeable batteries Other types Markings may burst causing personal injury or damage All products shall be permanently marked with manufacturer s name catalog number input and output ratings date of manufacture User Manual UL 2089 Shall be present as required and as appropriate Important Safety Section 31 34 Instructions Assembly Instructions Construction Check 7 Workmanship Visual Check Shall have no major defects such as external Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label internal Components shall be reliably mounted on PCB or other proper fixing 9 Internal Wires Visual Check Wireways shall be smooth and entirely free from sharp edges burrs fins moving parts and the like that may cause abrasion of insulation on conductors All soldering joint
121. ill be electrical items to reported as FAILED California 42 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard VOC if applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 425 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Battery mercury test USD 100 Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to
122. in a risk of injury UL 745 4 11 1 Edition If handles knobs and the like are used to indicate the position of Section 20 4 switches or similar components it shall not be possible to fix them in a wrong position if this might result in a risk of injury Section 20 18 to occur Shall be fitted with an on off switch which can be switched off by Section 20 19 the user without releasing his grasp on the tool Mechanical Strength UL 745 4 11 1 Edition Shall have adequate mechanical strength and be so constructed Section 19 as to withstand three drops from height of 1 meter or ball impact of 6 8 J per Section Supply Connections UL 745 4 11 1 Edition Saws provided with a power supply cord shall have cord and External Section 23 5 anchorages such that the conductors are relieved from strain Flexible Cables and including twisting where they are connected within the tool and Cords that their covering is protected from abrasion Compliance is checked by inspection This clause applies only to tools with separable batteries connected by a cord Electrical Safety 28 Component Check Visual Check If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohi
123. include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA027 US Clock Operated Switch Intertek Version 6 Date August 10 2011 Page 3 of 3 23 Ease of Installation Actual Use Follow directions for installation in Instruction manual Report relative ease of installation Report if instructions pertaining to installation are complete and understandable Parts shall be provided as claimed 24 Ease of Cleaning Actual Use Follow the cleaning instruction or wipe gently with damp cloth Removable parts shall be replaced easily and not causing any safety hazards as ae eee Additional test l 25 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California 26 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard VOC if applicable 8021B doc review substances GC MS screen
124. ing or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA028 US Photoelectric Switch Intertek Version 6 Date August 10 2011 Page 1 of 3 Test requirements Test Method Requirement Principle Document Review 1 Labelling Uniform Packaging Distributor s Name amp Address City State amp Zip Packaging or and Labelling Product Identification product Regulation Country of origin NAFTA amp
125. ing the Assembly Instructions installation use safety and maintenance All accessories shall be described in the user s manual and provided with instructions for proper use Construction Check 10 Packing 11 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label turning points edges or moving parts Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA033 US AC Adaptor Intertek Version 9 Date August 10 2011 Page 2 of 4 Test requirements Test Method 14 Accessibility of Live UL 1310 Cls 16 Inspect for access to live parts after removal of detachable parts Parts UL 60950 1 Cls 2 1 1 1 15 Power Cord UL 1310 Cls 14 2 The unit shall employ a Type SP 2 SPE 2 SPT 2 SV SVT SVT power supply cord Length shall gt 6 feet 1 8 m except for unit weighing 1 pound 454 g or less is acceptable if the total length of the input and output cords is 6 feet or
126. ings shall be provided in the user manual identifying Important Safety reasonable foreseeable uses or misuses of the product It shall also include Instructions instructions regarding the installation use safety and maintenance Assembly Instructions Construction Check SW FE S SO 17 Plug Visual Check Plug shall be 3 wire grounding type or 2 wire polarized attachment plug 18 Cord Type and UL 60065 Cls 16 A cord connected appliance shall be provided with an appropriate type and Length length of flexible cord per section 19 Component Visual Check If listing safety report provided report any difference of component used in Check the sample and the listing report Exclude plastic material insulation material or other without marking components 20 Dielectric Voltage UL 60065 Cls An appliance shall be capable of withstanding for 1 min when a test voltage Withstand Test 10 3 of 4240 VAC peak is applied between live parts and accessible metal parts without an indication of unacceptable performance 21 Accessibility of UL 60065 Cls Inspect for access to live parts after removal of detachable parts Live Parts 9 1 1 2 22 Temperature Test UL 60065 Cls 7 Under normal operating conditions supporting surface and all accessible surfaces shall not attain excessive temperature rise as described in Table 3 23 Strain Relief UL 60065 Cls Strain relief shall be provided to prevent a mechanical stress on a flexible 16 5
127. ious scratches on the external surface Peeling of rating or caution warning label internal Components shall be reliably mounted on PCB or other proper fixing 10 Internal Wires Visual Check Wireways shall be smooth and entirely free from sharp edges burrs fins moving parts and the like that may cause abrasion of insulation on conductors All soldering joints shall be mechanically secured before soldered All mechanical parts shall be securely fixed and prevented from turning Assembly Switch fuse and other protective device shall be connected at ungrounded conductors The polarization of conductors at plug and receptacles shall be matched 3 Cord Type and A cord connected appliance shall be provided with an appropriate type Length and length of flexible cord per section Fiectricalgatetyy IX E E FF FF WBE ri E FF A E 14 Component Visual If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 15 Dielectric UL 817 The insulation and spacings shall withstand the dielectric voltage Voltage Cls 88 withstand test without breakdown for a period of 1 min when a test Withstand Test voltage of 1250Vac is applied between a Live parts and accessible metal parts b Live parts of different polarity Live Parts protected against inadvertent contact with uninsulated live parts 17 Temperature UL
128. isual Check All mechanical parts shall be securely fixed and prevented from turning 10 Internal Wiring Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts 11 Accessibility of live UL 1449 Cls 55A 2 parts test An enclosure of a TVSS which prevents unintentional contact of current carrying parts or of film coated magnet wire in the enclosure of a TVSS As a result of the test the probes described in standard shall not touch the current carrying part or magnet wire Electrical Safety a eee een ty eee re 12 Component Check Visual If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking 13 Leakage Current Test UL 1449 Cls 31 the leakage current of cord connected or direct plug in TVSS shall not be more than 0 5 mA Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA039 US Transient Voltage Surge Intertek Suppresso
129. ithstand a steady pull equal to 3 times the product weight not less than 156N or greater than 220N in any direction for 1 minute This test shall be repeated 10 times with no mechanical strain or damage being transmitted to terminal or internal wiring through the power cord After the test the cable or cord shall not have been longitudinally displaced by more than 2 mm and the conductors shall not have moved over a distance of more than 1 mm in the terminals nor shall there be appreciable strain at the connection For the measurement of the longitudinal displacement a mark is made on the cable or cord while it is subjected to the pull at a distance of approximately 20 mm from the cord anchorage before starting the tests Fitness for Use 27 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 28 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 29 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be Wipe Gently with Damp replaced easily and not causing any safety hazards Cloth a ne Additional test 30 Chemi
130. l Shall function as intended as received Report details y of evaluation features tested methods used BV Lab Number Technician Name Test Date Reviewed By Date Page 4 of 5 DGEN 04255 US UNIVERSAL REMOTE CONTROL BATTERY OPERATED V11 Battery Product Compartment ANSI C18 1M part 2 03 Products with replaceable batteries shall be provided Design Guidance annex A CPSD HL with marking to indicate type of battery to use 01057 MTHD CPSD polarity alignment and how to insert correctly HL 01058 MTHD Compartments shall be designed so batteries are Dollar General secured in place and not fall out too easily Requirement positioned to minimize risk of user harm falling heat leaks especially for devices worn on body not making electrical contact if inserted backwards where practicable not a pressure hazard in case of cell venting free from metal that contacts or abrades the case jacket and may lead to short circuits Dollar General Requirement For the above battery reverse test if the battery could be insert in opposite position with reserve current generated the following tests applies Does not apply to button cell cells operated items e Reverse battery and measure temperature for 8 hours Monitor the temperature change of reversed batteries battery compartment and or other high risk locations Record changes of temperature report most significant observation The measured maximum tempe
131. ligations Product Spec DG EA038 US Outdoor Seasonal Use Cord Intertek Connected Wiring Devices Version 7 Date August 10 2011 Page 2 of 4 Test requirements Reference Method 12 Fittings UL 2438 Cls 7 An attachment plug cord connector or current tap provided on an outdoor seasonal use cord connected wiring device shall be rated 15 A 125 V and of the 2 pole 3 wire 5 15 configuration For sample employing an outlet fitting a There shall not be more than a total of 6 outlets including those provided at the end fittings and b The outlet fittings shall be factory assembled to the flexible cord and shall not be field rewireable 13 Drain Openings UL 2438 Cls 8 An enclosure body that permits water to enter the unit shall be provided with a drain hole E Electrical Safety 14 Component Check Visual If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking wiring device shall not be more than 0 5 mA 16 Rain Test UL 2438 Cls 24 2 amp 24 4 The enclosure is to be positioned in the focal area of the spray heads so that the greatest quantity of water enters the enclosure The water pressure is to be maintained at 5 Ibs in2 34 5 kPa at each spray head After test no water has entered the outdoor seasonal use cord connected wiring device and the unit is found to comply with th
132. llow directions for Report relative ease of installation Report if instructions pertaining installation in to installation are complete and understandable Instruction manual Parts shall be provided as claimed 23 Ease of Cleaning Follow Instructions Follow the cleaning instruction Removable parts shall be replace or Wipe Gently with easily and not causing any safety hazards Damp Cloth 24 Continuous Operation Actual use Under maximum loading condition for 4 hours the following shall not Test occur Emission of flame molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure Additional test 25 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be reported electrical items to as FAILED California 26 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS Product with solvent based liquid eg Adhesive paints glues and Substances VOC if screening US EPA etc shall not contain toxic aromatic compounds and hazard applicable method 5000 and substances 8021B doc review GC MS screening or US EPA method 5000 and 8021B In lieu of testing test
133. lowing shall not occur accessibility of live parts Actual use Function failure Ignition of the enclosure Emission of flame Molten metal or growing or flaming particles through any Shall meet the requirements in DG EA065 openings Creation of any openings in the enclosure that result in e All products containing CA Prop 65 warning label will be reported as FAILED DG EA065 Client requirement Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Volatile organic Substances VOC if applicable Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time GC MS screening US EPA method 5000 and 8021B doc review Product with solvent based liquid eg Adhesive paints glues and etc shall not contain toxic aromatic compounds and hazard substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Turnaround time 7 working day Sample size 3 pieces Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with thi
134. ls 120USD for 3 chemicals According to DG s requirement phthalates test would apply to this electrical item For additional charge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA057 US Universal Remote Control Intertek Version 4 Date Aug 16 2011 Page 1 of 2 penamaan eepe e e rT 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation Product Identification 2 Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported 3 Parts Inventor Shall meet label claims 4 General and Visual Check A general cautionary and warning marking intended to inform Cautionary Markings the user of a potential risk of fire electrical shock or injury to perso
135. ltage Voltage Clause 25 withstand test without breakdown applied between a live part and any Withstand Test accessible part 1240Vac 1 min 18 Accessibility of UL 773A An opening smaller than 1 inch 25 4 mm in an enclosure is acceptable Live Parts Clause 4 6 if a probe as illlustrated in the standard when inserted point first into an opening cannot be made ot touch any uninsulated live part or film coated wire 19 Temperature UL 773A Under normal operating conditions supporting surface and all Test Clause 21 accessible surfaces shall not attain excessive temperature as described in the standard Polymeric material shall not melt or deform in such a way as to interfere with normal operation of the product 20 Strain Relief UL 773A Strain relief shall be provided to prevent a mechanical stress on a Clause 34 1 flexible cord from being transmitted to terminals splices or interior wiring Shall withstand 35 Ib 1 minute 21 Continuity of In house method The resistance between the point of connection of the equipment grounding grounding means at or within the appliance and any other point in the connection grounding circuit of the appliance shall not exceed 0 1 ohms Fitness Use D TAH FP E iE FP IXE TE oF Fu GC 22 Functional Actual Use All the major features shall be matched with the installation and use Check instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other
136. manufacturer shown on manual label 21 Expandable Memory Visual Check As specified by manufacturer shown on manual label 22 Memory Media Type In house Method As specified by manufacturer shown on manual label 1 23 Interface method e g In house Method As specified by manufacturer shown on manual label USB 1 1 or 2 0 24 File Format In house Method As specified by manufacturer shown on manual label Supported e g MP4 JPEG on the construction shall be found Earn eine eee ree re ee Additional test 26 With Child Appealing DG EA051 Shall meet the requirements in DG EA051 Features 27 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California 28 Dollar General Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Client requirement Sample size 3 sets for DG EA058 US 12 sets for DG EA051 US Document required 1 Packaging or Packaging Artwork 2 User manual 3 Markings including rating label warning and caution markings 4 Safety certificate and report Turnaround time 7 working days Test charge 250USD 80 USD for DG EA051 US exclude chemical test Lead Content of Paints or Similar Surface Coating 25USD per coating Lead
137. mation and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA016 US 2VT IM Intertek Gains oe Date August 10 2011 Page 1 of 3 Ee 1 Labelling Uniform Packaging Distributor s name amp Address City State amp Zip shall be shown on the Packaging or and Labeling packaging product Regulations po Productidentification S O ee indicated to the ultimate purchaser of a product where it is made ericaton Ma 4 General and UL 2089 Battery chargers shall be marked CAUTION and following or Cautionary Section 29 equivalent Charge only __ type rechargeable batteries Other types Markings may burst causing personal injury or damage All products shall be permanently marked with manufacturer s name catalog number input and output ratings date of manufacture 5 User Manual UL 2089 Shall be present as required and as appropriate Important Safety Section 31 34 Instructions Assembly Instructions 6 Food Contact US FDA 21CFR 170 The product must meet the relevant requirements and verify the relative Requirement 189
138. model number 4 General Markings UL 1776 Cls 112 The following markings shall be legible and readily visible during use Manufacturer s name trademark or etc A distinctive catalog or model number or the equivalent Electric rating Date Code The maximum rated discharge pressure The cleaning solution intended to be used The maximum discharge temperature of fluid for which the product intended Other markings required by standard 5 Cautionary and UL 1776 Cls 113 A cautionary or warning marking intended to inform the user of a Warning Markings potential risk of fire electrical shock or injury to persons shall be provided 6 User Manual UL 1776 Cls 114 117 Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regarding the Assembly Instructions installation use safety and maintenance All accessories shall be described in the user s manual and provided with instructions for proper use ConstructionCheck ft 9 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label turning points edges or moving parts 12 Accessibility of UL 1776 Cls 15 To reduce the risk of unintentional contact that may involve a risk Uninsulated live Parts of
139. n Name Test Date Reviewed By Date Page 5 of 6 DGEN 04034 US WIRELESS HEADPHONE V11 Evaluation Citation Method Noot Criteria VT Results Rating Samples Battery Product Compartment ANSI C18 1M part 2 03 Products with replaceable batteries shall be provided Design Guidance annex A CPSD HL with marking to indicate type of battery to use 01057 MTHD CPSD polarity alignment and how to insert correctly HL 01058 MTHD Compartments shall be designed so batteries are Dollar General secured in place and not fall out too easily Requirement positioned to minimize risk of user harm falling heat leaks especially for devices worn on body not making electrical contact if inserted backwards where practicable not a pressure hazard in case of cell venting free from metal that contacts or abrades the case jacket and may lead to short circuits Dollar General Requirement For the above battery reverse test if the battery could be insert in opposite position with reserve current generated the following tests applies Does not apply to button cell cells operated items e Reverse battery and measure temperature for 8 hours Monitor the temperature change of reversed batteries battery compartment and or other high risk locations Record changes of temperature report most significant observation The measured maximum temperature rise shall be less than 45K Rated as FAIL if there is any malfunction noted a
140. n a test Withstand Test voltage of 4240 VAC peak is applied between live parts and accessible metal parts without an indication of unacceptable performance 20 Accessibility of UL 60065 Cls 9 1 1 2 Inspect for access to live parts after removal of detachable parts Live Parts 21 Temperature Test UL 60065 Cls 7 Under normal operating conditions supporting surface and all accessible surfaces shall not attain excessive temperature rise as described in Table 3 22 Strain Relief UL 60065 Cls 16 5 Strain relief shall be provided to prevent a mechanical stress on a flexible cord from being transmitted to terminals splices or interior wiring 23 Stability Test UL 60065 Cls 19 1 Apparatus having a mass of 7 kg or more shall have adequate stability During the tests the apparatus shall not overturn when inclined at an angle at 10 to the horizontal 24 Continuity of UL 60065 Cls 15 2 The resistance of the connection between the PROTECTIVE grounding EARTHING TERMINAL or contact and parts required to be connected connection thereto shall not exceed 0 1 ohm AC Adaptor Operated Document Review T 25 General and UL 1310 Charger shall be legibly and permanently marked Cautionary Cls 49 1 a The manufacturers name trade name or trademark Markings b The date or other dating period of manufacture not exceeding any three consecutive months c A distinctive catalogue or model number or the equivalent and d The electr
141. n grounding circuit of the appliance shall not exceed 0 1 ohms 21 Accessibility of UL 60950 1 CSA The articulate accessible probe figure NAF 1 shall not contact Moving Parts C22 2 NO 60950 1 hazardous moving parts Clause NAF 4 4 2 After any mechanical enclosures or guards that are removable without the use of tool shall be removed The accessibility probe wedge figure NAF 2 and NAF 3 shall not contact hazardous moving parts with the following forces applies Strip cut type shredder 45 N Cross cut type shredder 90 N Fitness for Use 22 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 23 Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 24 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be replaced Wipe Gently with easily and not causing any safety hazards Damp Cloth diionagest IN E E EEE WE Mm E E A E Cherflical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electri
142. nce Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC if 8021B doc review applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA032 US Cordless Telephone Anwering Mac
143. nce could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shall meet label claims Construction Check 9 Packing No hazard when removing the packing 10 Workmanship Visual Check Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Technical informa
144. nd the test pin with a force of 10 N It shall not be possible to touch bare live parts or live parts protected by lacquer enamel ordinary paper cotton oxide film beads or sealing compound only with the test finger For Class II tools it shall not be possible to touch bare live parts with the test pin shown in Figure 2 or to touch metal parts separated from live parts by basic insulation only with the test finger shown in Figure 1 15 Fit Characteristics UL 745 2 4 Shall fit recognized receptacles without any exposure of live Of Plug parts and with good conduction Cord Length UL 745 2 4 A tool shall be provided with flexible cord permanently attached to the tool and with an attachment plug which may be of the locking type for connection to the power supply circuit Flexible cords on tools not eR to be used with liquids shall be 1 less than 0 5 m long or 2 equal or greater than 1 8 m long Grounding UL 745 2 4 A tool must employ either a 2 Wire polarized or a 3 Wire grounding plug Drop Test UL 745 2 4 The unit shall withstand being dropped 3 times on a concrete Cls 19 1 mod surface from a height of one meter After the tests sample shall be no live parts exposure It shall not be possible to touch bare live parts or live parts protected by lacquer enamel ordinary paper cotton oxide film beads or sealing compound only with the test finger For Class II tools it shall not be possible to touch bare live parts with the te
145. nen e Asante eae eden mes 42 038 Outdoor Seasonal Use Cord Connected Wiring Devices Rev 08 15 2011 ssssssssssssssssrsssrsssrsssrssrssessses 46 039 Transient Voltage Surse Suppressor Rev OSA SAOL hecesi an i n iaei 50 040 High Pressure Cleaning Machine Rev 08 15 2001 vss scscsssnisastesandeoiscciwastarsedeapsdvacout R AE E ERE ORS 53 046 Cordless Multi Tools Rey OS 579011 J as sasciassasdsanesaseiavadasecdosdasedansvasdcdon vaseiavavaseiaordarddanssasdianvnawiauenaseies 57 048 Battery Operated Reciprocating Saw Jig and Sabre Saws Rev 08 15 2011 sccssececeseeesteceeneeeeenees 61 049 Portable Electric Sander Rev 08 15 2011 0ss0sssescsssssssnuvessecsscsccssssssscsensectecssssssesensncsessssescessansousvess 66 053 Headphone Earphone and Loudspeaker Rev 03 24 2010 cssssadacsaeedsisssctesssneseeassivsdecimmunncsvasneasts 70 056 Audio Video USB Cables Rev 03 24 2010 0s0sssccccctesssvssveccccnvtccssvesvesconsvtacssvesvessscevvecsssesscassncuvessess 74 057 Universal Remote Control Rev Ga 001 nate Rocio adie Rae 76 03s Digital Phote Key Cham Res WS US001 sicestslesciseescarnedsdarvmvscetenl darinasadinaniam AENA E AOE 78 059 Video Game Console Rev 08 15 2011 c c cccccsssssscsccccccssesssescccccscessusssessecceeessssesecsecsseussussesesssesseussuesess 80 061 Booster Cable Rev OS 150001 jays icasnasexc sina EEEE E E A EEE EAEE 84 062 Power Inverter Rev O87 52011 iiisss isa sesarssacin a EE AEREE RE E ESARTE
146. ngs persons shall be provided Marking shall contain at least Manufacturer s name or trade mark or identification mark Manufacturer s model or type reference Rated voltage for AC product Rated frequency for AC product Rated current for AC product Class II symbol for class Il equipment only 5 User Manual UL 60950 1 Cl 1 7 2 Instructions and warnings shall be provided in the user manual Important identifying reasonable foreseeable uses or misuses of the Safety product It shall also include instructions regarding the Instructions installation use safety and maintenance Assembly Instructions For product provided with AC adaptor the instruction shall state that the socket outlet shall be installed near the equipment and shall be easily accessible 7 FCC Part 68 Visual Marking shall include marking and US AAAEQ TXXX instruction AAA responsible party s grantee code EQ equipment code ringer equivalence number T i ringer type XXX product identifier HAC for telephone only 8 FCC part 15 Shall provide FCC part 15V report for verification Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any as
147. ns shall be provided 5 User Manual Visual Check Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regarding the Assembly Instructions installation use safety and maintenance 6 US FCC Part 15 Document Check If product use RF not infra red for transmission shall have valid Rules FCC part 15C report If product use Infra red for transmission and internal operating frequency gt 1 705 MHz shall have valid FCC part 15V report 7 US FCC Part 15 Visual Marking shall include marking and FCC part 15C FCC ID instruction This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates
148. nstruction manual Report relative ease of installation Report if instructions pertaining to installation are complete and understandable Parts shall be provided as claimed Follow Instructions or Wipe Gently with Damp Cloth Removable parts shall be replaced easily and not causing any safety hazards Additional test ee oh SS eee Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA008 US Corded Telephone Answering Machine Intertek Caller ID Version 10 Date Aug 16 2011 Page 4 of 4 30 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California Dollar General Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Client requirement Toxics in Client requirement packaging Sample size 3 sets Turnaround time 7 working days Test charge 200USD For additional char
149. o AC operated audio and video products UL 1310 UL 60065 amp 60950 1applicable to AC adaptor operated audio and video products 2 Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA008 US Corded Telephone Answering Machine Intertek Caller ID Version 10 Date Aug 16 2011 Page 1 of 4 Requirement Document Review 1 Labeling Uniform package Distributor s Name amp Address City State amp Zip Packaging or and labeling product regulations Product Identification 2 Country of NAFTA amp Country Of Origin If Imported origin FTCA Sect 5 3 Safety Visual Shall have valid UL or ETL listing Verify listing by NRTL product Certification directory with the sample s listing number and model number Mark 4 General and UL 60950 1 CI 1 7 A general cautionary and warning marking intended to inform Cautionary the user of a potential risk of fire electrical shock or injury to Marki
150. od 16 Power Input Test 17 Temperature Test 18 Strain Relief Fitness for Use 19 Functional Check 20 Ease of Installation 21 Continuous Operation Additional test 22 Chemical amp Energy Efficiency test for all electrical items to California Dollar General Certificate of Compliance Toxics in packaging Volatile organic Substances VOC if applicable Additional Charge Item UL 458 Cls 33 UL 458 Cls 38 UL 458 Cls 42 1 Actual Use Follow directions for installation in Instruction manual Actual use DG EA065 Client requirement GC MS screening US EPA method 5000 and 8021B doc review Testing Charge amp Sample Size amp Turnaround Time The input current to a inverter shall be measured with the inverter operating while connected to the maximum normal load The current input shall not be more than 110 percent of the rated value With the output load adjusted to deliver the maximum normal load current an inverter shall not attain a temperature at any point high enough to constitute a risk of fire or exceed the temperature limits as below Supporting surface plastic metal 90 C 90 C Handle or Knob plastic metal 85 C 60 C Other accessible part plastic metal 95 C 70 C The strain relief means provided on a flexible cord shall withstand for 1 minute without displacement a direct pull of 35 pounds 156 N applied to the cord with the conne
151. on 13 Date August 10 2011 Page 5 of 6 Test Item Test Method 40 Output current UL 1310 The maximum output current shall not exceed the value specified in and power test Cls 28 2 Table 28 1 and the maximum output volt amperes shall not be more Inherently Limited than 100 volt amperes except as indicated in 28 2 3 and 28 3 1 41 Output current UL 1310 When the unit includes means to automatically de energize the output and power test Cls 28 3 circuit the values of the output current and volt amperes shall not Inherently Limited exceed those specified in Table 28 2 42 Dielectric UL 1310 Shall withstand for 1 minute without breakdown Withstand Cls 32 a One thousand volts AC plus twice the maximum rated voltage between 1 The primary circuit and accessible dead metal parts and 2 The primary and secondary circuit or circuits b One thousand volts AC plus two times the sum of secondary voltages between secondary windings for units described in 26 3 or 28 2 3 c Five hundred volts AC between a secondary circuit and dead metal parts d A DC potential of 1 414 times 2 V 1 000 where V is the RMS supply voltage between the terminals of a capacitor used for radio interference elimination or arc suppression UL 60950 1 No breakdown occurs at 2000Vac 1 min between AC mains and Cls 5 2 2 and 6 2 2 accessible parts No breakdown occurs at 1500Vac 1 min between telephone line interface and handset No breakdown occurs a
152. ons regarding the Assembly Instructions installation use safety and maintenance ConstructionCheck 6 i 7 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label turning Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts Fitness for Use I Be BH E sf IE 10 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 11 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 12 Cord Anchorages UL 60950 Cls 3 2 6 Interconnecting cables shall not rotate in relation to the body of the product to such an extent that mechanical strain is imposed on the electrical connections 13 Strain relief UL 60950 Cls 3 2 6 Interconnecting cables shall be able to sustain a pull force of 30N without longitudinally displayed by more than 2 mm nor shall there be appreciable strain at the connections 14 Drop test UL 60950 Cls 4 2 6 Product shall function normally after the product was dropp
153. opying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA033 US AC Adaptor Intertek Version 9 Date August 10 2011 Page 1 of 4 Test requirements Test Method Document Review y 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation 2 Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking If imported 3 Safety Certification Visual Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and model number 4 Energy Efficiency for Visual Shall meet tier 1 of energy efficiency requirement of section Arizona 1605 3 of California Code of Regulations title 20 division2 chapter 4 article 4 The following shall be provided a Test report 5 DOE requirement 10 CFR 430 Shall have valid DOE certification report for verification 6 General Markings UL 1310 Cls 51 Class 2 Transformer shall be legibly and permanently marked a Manufacturer s name trade name or trademark A distinctive catalogue or model number or the equivalent The date or other dating period of manufacture not exceeding any three
154. or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure Shall meet the requirements in DG EA065 e All products containing CA Prop 65 warning label will be reported as FAILED Shall provide signed chopped document Dollar General Toxics in Packaging Certificate of Compliance Client requirement Product with solvent based liquid eg Adhesive paints glues and etc shall not contain toxic aromatic compounds and hazard substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its
155. or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure the product shall not exceed the maximum output rating of the AC adaptor Additional test ai ae ee ee O 30 Chemical amp Energy DG EAO65 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances VOC if EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Com
156. ovided in the user manual identifying reasonable foreseeable uses or misuses of the UL 1310 Cl 54 A j g a product It shall also include instructions regarding the installation use safety and maintenance ga 091 Cis 1 5 All accessories shall be described in the user s manual and provided with instructions for proper use Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label Visual Page 2 of 4 MODERN TESTING SERVICES TEST PROTOCOL DOLLAR GENERAL AC ADAPTOR EL 91310 US V1 a MTS Report Number Date Not Applicable Internal Wiring Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts Documentation Accessibility of Live oP ter ce 18 Inspect for access to live parts after removal of detachable parts Review Parts UL 60950 1 CIs 2 1 1 1 SP P P The unit shall employ a Type SP 2 SPE 2 SPT 2 SV SVT SVT power supply cord UL 1310 Cls 14 2 Length shall gt 6 feet 1 8 m except for unit weighing 1 pound 454 g or less is acceptable if the total length of the input and Documentation Power Cord output cords is 6 feet or more and the length of input cord is gt 3 feet Check Construction Check Construction Check Check Electrical Safety Review UL 60950 1 Cls 3 2 1 1 The unit shall be provided with termnials for permanent connection
157. p Address City State amp Zip Packaging or and Labelling Product Identification product Regulation 2 Country of origin NAFTA amp FTCA Sect Country Of Origin If Imported marking lf 5 imported Certification Mark directory with the sample s listing number and model number 4 User Manual UL 60950 1 Instructions and warnings shall be provided in the user manual Important Safety Clause 1 7 identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assembly maintenance Instructions 5 General and UL 60950 1 A general cautionary and warning marking intended to inform the user Cautionary Clause 1 7 of a potential risk of fire electrical shock or injury to persons shall be Markings provided 6 Warning Markings UL 60950 1 CSA Symbols alerting the user to the following considerations shall be for C22 2 NO 60950 1 provided adjacent to the document feed opening Household Home_ Cls NAF 1 7 18 product is not intended for use by children product is not a toy Office Document avoid touching the document feed opening with hands Shredders avoid clothing touching the document feed opening avoid hair touching the document feed opening keep aerosol products away for products incorporating a universal brush motor only symbol A shall be marked to alert the user to the presence of important operating maintenance
158. ples SUPPLEMENTAL PROTOCOLS Note Additional cost sample size and TAT may be required if testing to 1 or more supplemental protocols is necessary Please refer to the below referenced supplemental protocol s for additional information Electronic products shall have complied with FCC Industry Canada regulations appropriate for the country of destination as shown by evaluation to the cited protocol Products under FCC Verification or CPSD EL PTCL Declaration of Conformity must be submitted with 04999 9 NA CPSD complete and correct test reports Designs claimed to EL 01096 MTHD be exempt from FCC IC equipment authorization due to an un obvious feature like electronic frequency must be submitted with acceptable supporting technical documents Federal Communications Commission FCC Part 15 industry Canada document management Shall pass Primary Battery Powered Product module Primary battery powered product CPSD EL PT 10000 Notes to lab Primary battery powered i i module Dollar General Requirement product P Please see performance section below for Battery Product Compartment Design Guidance test For Class 2 Transformer ANSVUL 1310 3 Star Audit Shall Pass 3 star electrical safety audit Complete Test Package provided upon request For I T E Transformer Electrical Safety Audit CPSD EL PTCL 60950 02 NA Electrical Safety Audit Shall pass 2 star electrical safety audit
159. pliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA033 US AC Adaptor Version 9 Date August 10 2011 Page 4 of 4 Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA038 US Outdoor Seasonal Use Cord Intertek Connected Wiring Devices Version 7 Date August 10 2011 Page 1 of 4 Document Review ee el 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation Product Identification markin
160. pying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA059 US Video Game Console Intertek Version 5 Date August 10 2011 Page 4 of 4 Test requirements Reference Requirement Method 38 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California 39 Dollar General Client Shall provide signed chopped document Dollar General Toxics in Certificate of requirement Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS Product with solvent based liquid eg Adhesive paints glues and etc Substances screening US shall not contain toxic aromatic compounds and hazard substances VOC EPA method 5000 if applicable and 8021B doc GC MS screening or US EPA method 5000 and 8021B review In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample
161. r Version 6 Date August 10 2011 Page 2 of 3 Test requirements Reference Method 14 Dielectric Voltage UL 1449 Cls 32 A TVSS shall withstand a 60 Hz sinusoidal potential of 1000 V Withstand Test plus twice maximum rated supply voltage without breakdown for 1 minute between the following a Uninsulated live metal parts and the enclosure A nonconductive enclosure is to be wrapped in conductive foil b Terminals of opposite polarity c Uninsulated live metal parts and accessible dead metal parts d Uninsulated live metal parts and grounding contacts of grounding type receptacles e Primary and isolated secondary circuits Strain Relief Test UL 1449 Cls 46 The strain relief means provided on the supply cord shall withstand for one minute without displacement a direct pull of 156 N 35 Ibf applied to the cord with the connections within the TVSS disconnected Over Voltage Test UL 1449 Cls 36 A TVSS shall withstand an overvoltage of 110 percent of the rated supply voltage for 7 hours without evidence of a risk of fire or electric shock The TVSS is to be connected to a supply source maintained at 110 percent of the rated voltage Grounding Continuity UL 1449 Cls 38 TVSS provided with means for grounding shall be tested to Test determine that the impedance between the grounding pin terminal or lead and the accessible dead metal parts of the TVSS that are likely to become energized is not more than 0 1 ohm Drop impact t
162. r immunity from legal obligations Product Spec DG EA049 US Portable Electric Sander Intertek Version 6 Date August 10 2011 Page 3 of 4 Test requirements Reference Method 23 Leakage Current UL 745 2 4 A measurement is made of the leakage current which may flow from any pole of the supply to accessible metal parts and metal foil with an area not exceeding 20 cm x 10 cm in contact with accessible surfaces of insulating material connected together and to metal parts of Class II tools separated from live parts by basic insulation only for Class tools for Class Il tools 0 25 mA Current Input Test UL 745 2 4 If the tool is marked with rated current the current taken by the tool under normal load shall not exceed the rated current by more than 15 percent Compliance is checked by measuring the current taken by the tool operating under normal load conditions at rated voltage or at the mean value of the rated voltage range if the voltage range does not exceed 10 percent of its mean value If the tool is marked with rated Watt the measured value shall meet requirement of clause 10 1 Dielectric UL 745 2 4 The dielectric strength test for whole product Breakdown No dielectric break down or flashover at 1250VAC for 1 Min in Basic Insulation 2500VAC for 1 Min in Supplementary insulation if present 3750VAC for 1 Min in Reinforced insulation if present Strain Relief UL 745 2 4 Power cord shall w
163. r test the battery shall not explode or catch fire or chemical leaks Temperature of battery pack casing shall not exceed 150 degC 49 Overcharge Test In house Method Fully charge the product according to user instruction Additional charge for 7 hours No overheat melting of parts and chemical leakage shall occur Additional test 50 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 and shall not contain toxic aromatic compounds and hazard substances VOC 8021B doc review if applicable GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Sample size 3 sets Turnaround time 7 working days Testingcharge Sample size e Basic charge USD 400 3sets Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark 1 UL 60065 1492 amp 60950 1 applicable t
164. rature rise shall be less than 45K Rated as FAIL if there is any malfunction noted after the test or the measured temperature rise exceeded the limit Remark PPR Pre Production Review VT Verification Test Key BV Lab Number Technician Name Test Date Reviewed By Date Page 5 of 5 Additional Charge For This Test Tk Mandatory Requirement By Request Only Result Key C Claimed R Recorded M Meets NM Does Not Meet NA Not Applicable NT Not Tested Rating Key Incomplete INCOMPLETE PPT Rating Only Complete PPT COMPLETE Rating Only GOOD Good UNSAT Unsatisfactory No Of Samples Required for Complete Testing Client Approval APRIL 02 2012 No Of Fully Packed Cartons For Transit Testing A Chuck Rogers No Of Working Days For Complete Testing Creanon Date MAY Oy 2008 Last Revision Date NOVEMBER 18 2011 Pricing Review Date Technical Review Date ZN MODERN TESTING SERVICES TEST PROTOCOL MTS DOLLAR GENERAL AC ADAPTOR N I EL 91310 US V1 MTS Report Number Date Test Properties CPSC Regulated ets ATT As Evaluation Citation Method Review Shall meet the specific requirement in the protocol Supplemental Documentation Supplementary Protocol CA65 Protocol Review CA65 SP 572 US The component applicable for phthalate test will follow client practice for CPSIA Electronic products shall have complied with FCC regulations as shown by evaluation to the cited protocol Products under
165. rement Remark the missing information instead of fail i Country of origin Labeling P Packaging Review mard N Roro NAFTA amp FTCA Sect 5 Country Of Origin If Imported Labeling i Swe Va rn Certifig tion Shall have valid UL or ETL listing Verify listing by NRTL product directory with the sample s listing number and model number Shall meet tier 1 of energy efficiency requirement of section 1605 3 of California Code of Regulations title 20 division2 chapter 4 article 4 The following shall be provided a Test report Documentation Energy Efficiency for Document Review i ocument Revie Review Arizona Document Review e DOE requirement 10 CFR 430 Shall have valid DOE certification report for verification Page 1 of 4 E N MTS z a Packaging Review General Markings User Manual Important Safety Instructions Assembly Instructions Packaging Review Construction Check est Properties Labeling Labeling Labeling Labeling Check Not Applicable Workmanship Construction Check E Packaging Review Cautionary Markings Review Packaging Review Parts Inventory Shall meet label claims Not Applicable No hazard when removing the packing Not Applicable Mechanical Assembly Visual Check All mechanical parts shall be securely fixed and prevented from turning MODERN TESTING SERVICES TEST PROTOCOL DOLLAR GENERAL AC ADAPTOR EL 91310 US V1 MTS Report Number Date Class 2 Transformer
166. report and document Note Proper documentation should be available to demonstrate that the materials are of US FDA approved food grade If no documents can be provided additional FDA test required ee ee ee ee eee 7 Packing No hazard when removing the packing 8 Parts Inventory Shall meet label claims 9 Workmanship Visual Check Shall have no major defects such as external Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label internal Components shall be reliably mounted on PCB or other proper fixing 11 Internal Wires Visual Check Wireways shall be smooth and entirely free from sharp edges burrs fins moving parts and the like that may cause abrasion of insulation on conductors All soldering joints shall be mechanically secured before soldered 12 Mechanical Visual Check All mechanical parts shall be securely fixed and prevented from turning Assembly 13 Accessibility of UL 2089 J Section 15 1 1 Parts over 60 V shall not be accessible 14 Polarization Visual Check Switch fuse and other protective device shall be connected at ungrounded conductors The polarization of conductors at plug and receptacles shall be matched Shall be one of listed types SPT 2 etc If in Class 2 or limited energy Length Section 12 1 LVLE circuit insulation thickness may be 0 33 mm 16 Protective UL 2089 Report type and rating of protective device Prot
167. requirement 10 CFR 430 For Power supply 6 General and UL 745 3 Cautionary Cls 7 1 Markings UL 745 3 Cls 7 2 UL 1310 Cls 49 1 UL 1310 Cls 49 4 User Manual UL 745 4 1 Important Safety Cls 31 Instructions Assembly Instructions Cadmium and Lead containing batteries shall bear 3 chasing arrows or comparable recycling symbol and Ni Cd or nickel cadmium and BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY Pb or LEAD RETURN and RECYCLE and BATTERY MUST BE RECYCLED if sealed Shall have valid UL or ETL listing Verify listing by NRTL product directory with the sample s listing number and model number Shall have valid DOE certification report for verification It is the vendor s responsibility to submit the certification report and compliance statement to DOE Tools shall be marked with rated voltage s in volts symbol for direct current manufacturer s name trade mark or identification mark manufacturer s model or type reference date of manufacture Warning To reduce the risk of injury user must read and understand instruction manual Tools enclosures containing separable or detachable batteries shall be marked with rated voltage s in volts symbol for direct current manufacturer s name trade mark or identification mark manufacturer s model or type reference Charger shall be legibly and permanently marked a The manufacturer
168. rking day Sample size 3 pieces Testing charge Sample size Basic charge USD 300 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA046 US Cordless Multi Tools Intertek Version 5 Date August 10 2011 Page 1 of 4 e a rT Labeling Uniform Labeling Distributors Name amp Address City State amp Zip Packaging or Regulation product Product Identification Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking 3 FCC part 15 Visual If the operating frequency over 9kHz for AC operated or 1 705MHz for BO operated product FCC report shall be provided for checking FCC Part 15 Visual Marking shall include marking and This device complies with Part 15 of the FCC Rules ins
169. rmation and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations 3 4 5 6 7 Product Spec DG EA049 US Portable Electric Sander Intertek Version 6 Date August 10 2011 Page 2 of 4 Test requirements Reference Method 13 Internal Wiring Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts 14 Live Parts UL 745 2 4 The enclosure of the tool shall have no openings other than those necessary for the use and working of the tool giving access to live parts and for Class II tools to parts separated from live parts by basic insulation only Compliance is checked by inspection and by a test with the standard test finger shown in Figure 1 In addition apertures in Class II tools and apertures in Class tools other than those in metal parts connected to an earthing terminal or earthing contact are tested with the test pin shown in Figure 2 After removal of detachable parts the test finger and the test pin are applied in every possible position the test finger being applied without appreciable force a
170. roduct 10 Packaging Instructions or Product 11 Packaging Instructions or Product Packaging Instructions or Product Mercury Containing and Rechargeable Battery Management Act Pub L 104 142 13 May 1996 Stat 110 1333 Mercury Containing and Rechargeable Battery Management Act Mercury Labeling as applicable to Button Cell Battery powered devices If Applicable 16 User Manual Important Safety Instructions Assembly Instructions 17 Parts Inventory Visual Visual Visual Title Rechargeable Battery Recycling Act U S Pub L 104 142 13 May 1996 Stat 110 1333 Mercury Analysis EPA Guidance Best Practice Title II Various State Laws including VT Title 10 Chapter 159 Sec 6621d RI Title 23 Chapter 23 24 9 NH title x Chapter 149 M Sec 149 M 51 149 M 57 CT Public Act 02 90 NY Chap 145 Title 21 Ch 27 2101 2115 Visual For products with more than one battery must include Do not mix old and new batteries Do not mix alkaline Standard Carbon Zinc Or Rechargeable Nickel Cadmium Batteries If sample is equipped with permanently connected batteries that are not replaceable a warning shall be provided that states Do not dispose of this product in fire Batteries inside this product may explode or leak or the equivalent If sample is provided with batteries but the batteries can be removed or replaced a warning shall be
171. rt and any accessible part 1240Vac 1 min All exposed dead metal parts that are exposed to contact during any servicing operation including maintenance and repair and that can become energized shall be electrically connected to the grounding terminal and with earth resistance not more than 0 1 Ohm An opening smaller than 1 inch 25 4 mm in an enclosure is acceptable if a probe as illlustrated in the standard when inserted point first into an opening cannot be made ot touch any uninsulated live part or film coated wire Under normal operating condition the accessible parts shall not attain excessive temperature as follows Cord 35 C Polymeric material used as decorative parts shall not melt or deform in such a way as to interfere with normal operation of the product The product shall be provided with strain relief so that a pull of 35 Ibf 156 N exerted on the power supply cord is not transmitted directly to a terminal splice or interior wiring of the unit All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to
172. ry information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA017 US Relocatable Power Tap Version 7 Date August 10 2011 Intertek Page 2 of 3 18 Temperature Test UL 1363 2ed Cls 22 Under maximum loading the overcurrent protective device shall not open the circuit the enclosure surface receptacle contacts and separation of the supply cord shall not attain excessive temperature as follows Enclosure Surface 70C Supply Cord 60 Receptacle Contacts 55 19 Grounding Continuity Standard measure Each product shall be tested to determine that continuity between all Test blades and pin of attachment plug and end terminal or receptacle of the female connector by using a digital multimeter Continuity Test In House Method Each product shall be tested to determine that continuity between all blades and pin of attachment plug and end terminal or receptacle of female connector emee conector SY using a digital multimeter finess for Use Functionality Check aas Use To check if the e E E op E ATE is able to operate as intended according to the instruction manual 22 Ease of Installation Fo
173. s forUse as Use To check if the e e E o ae e E A e is able to operate as intended according to the Check instruction manual 32 Continuous Actual use Under maximum loading condition for 4 hours the following shall not Operation Test occur Emission of flame molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure After fully charged the battery charge for an addition of 7 hours No ena Ce emission of flame shall occur Additional test Chemical amp ee EA065 namere annen eens meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Toxics in Client requirement packaging Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues and etc Substances EPA method 5000 shall not contain toxic aromatic compounds and hazard substances VOC if and 8021B doc applicable review GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time
174. s problems 35 Ease of Installation Follow directions for Report relative ease of installation Report if instructions installation in Instruction pertaining to installation are complete and understandable manual Parts shall be provided as claimed 36 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be Wipe Gently with Damp replaced easily and not causing any safety hazards Cloth Additionaltest 37 Chemical amp Energy DG EAO65 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California 38 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard VOC if applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lieu of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge
175. s shall be mechanically secured before soldered Assembl 11 Polarization Visual Check Switch fuse and other protective device shall be connected at ungrounded conductors The polarization of conductors at plug and receptacles shall be matched Shall be one of listed types SPT 2 etc If in Class 2 or limited energy Length Section 12 1 LVLE circuit insulation thickness may be 0 33 mm 13 Protective UL 2089 Report type and rating of protective device Protective devices shall be Devices Section 9 rated no more than 8 A for 12 V systems or 4 A for 24 V systems Protective devices not within the cigarette lighter connector shall be no more than 5 away by the conductor Protective devices shall otherwise be per section Electrical Safety 14 Component Visual If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components Withstand Test Section 25 hipot test Section 28 18 Temperature Test UL 2089 When tested with rated load maximum temperature rise allowable Section 24 1 accessible surface Mod Accessible surfaces only shall not exceed Mod temperatures specified line c Protective devices shall not operate 19 Maximum Output UL 2089 Maximum output shall be no more than 60 V Voltage Test Section 22 1 E Fitness for Use ed Technical information and related recommendations lis
176. s specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA038 US Outdoor Seasonal Use Cord Connected Wiring Devices Version 7 Date August 10 2011 Page 4 of 4 Testing charge Sample size Basic charge USD 300 Additional charge Chemical amp Energy Efficiency test for all electrical items to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA039 US Transient Voltage Surge Suppressor Version 6 Date August 10 2011 Page 1 of 3 Test requirements Reference Method Document Review CE 1 Labelling Packaging Uniform Labelling or product Regulation 2 Country of origin NAFTA amp FTCA Sect 5 marking If imported Safety Certification Visual Mark 3 4
177. shall not exceed Mod temperatures specified line c Protective devices shall not operate Maximum Output UL aT Maximum output shall be no more than 60 V Voltage Test C 22 1 Fitness for Use 22 Functionality Use SRT SSE check if the product is able to operate as intended according to the Check instruction manual 23 Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 24 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be replace easily Wipe Gently with and not causing any safety hazards Damp Cloth 25 Continuous Actual use Under maximum loading condition for 4 hours the following shall not Operation Test occur Emission of flame molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure or functional failure 26 Stability Mug In house method Place mug filled with liquid at a 10 incline Verify the mug holder does not tip over Adeltional test Bi E Z re UC Chemical amp Be ne Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California
178. sociated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA008 US Corded Telephone Answering Machine Intertek Caller ID Version 10 Date Aug 16 2011 Page 2 of 4 9 FCC Part 15 Visual Marking shall include marking and This device complies with Part 15 of the FCC Rules instruction Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which
179. st pin shown in Figure 2 or to touch metal parts separated from live parts by basic insulation only with the test finger shown in Figure 1 supplementary insulation or reinforced insulation is subjected to an electric strength test as in Sub clause 15 3 but with 75 percent of the values specified Holder Assembly dead metal part exposing a live part when a brush is worn out 20 Switches amp Controls UL 745 2 4 A switch or other controller device shall have a voltage rating and an ampacity not less than the corresponding values of the load it controls A tool shall not employ a through cord switch A single pole switch employed in a tool having a nominal rating of 120V shall be connected in the ungrounded conductor circuit Accessories eee in an increased risk of i et to persons Electrical Safety 22 Component Check Visual Check ee listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other components without marking Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confe
180. structions shall be preceded by the heading IMPORTANT SAFETY INSTRUCTIONS and this is to be followed by the statement SAVE THESE INSTRUCTIONS 7 Palis Inventor Shall meet label claims No hazard when removing the packing 7 Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 10 Mechanical Assembly Visual Check All mechanical parts shall be securely fixed and prevented from turning Insulation Thickness UL 1839 Cls 3 2 The conductor insulation material shall be thermoplastic or a thermoset with a minimum average insulation thickness of not less than 1 5 mm 0 06 in for 10 2 AWG 6 35 mm wire and 2 0 mm 0 08 in for 1 4 0 AWG 50 120 mm 7 wire A separator shall be used between uncoated conductors and insulations with a sulfur cure Separators are optional for other constructions 12 Cord aoe T UL 1839 Cls 3 3 The booster cable set shall not be less than 3700 mm 12 ft in length measured from jaw end to jaw end Electrical Safety eof ie tmawanaiaend Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the saf
181. t 1000Vac 1 min between telephone line interface and other accessible parts UL 60065 The Product shall withstand Cls 10 3 2 _4200Vpeak for 1 minute between live parts of input circuits and live parts of output circuits 4200Vpeak for 1 minute between live parts of input circuits and user accessible surface 43 Strain Relief UL 1310 Cls 41 Supply cord shall withstand a 35 Ibf 156 N strain for 1 minute For units employing a flexible output cord the cord shall subject to a 20 lbf 89N for 1 minute without damage UL 60950 1 Power supply cord shall withstand the following pull force for 25 times 1 Cls 3 2 6 second each Mass of equipment kg lt 1 30 N 1 lt Mass of equipment kg lt 4 60 N Mass of equipment ki UL 60065 Shall withstand 40N 1 second 100 times pull force Cls 16 5 44 Direct Plug In UL 1310 Cls 43 Each blade and the grounding pin if provided shall withstand a direct Blade pull of 20 Ibf 89 N for 2 minutes without loosening The two blades Secureness Test tested together shall also withstand a direct pull of 20 Ibs for 2 minutes without loosening UL 817 for other than UL 1310 Each blade and pin shall be capable of withstanding a pull of 20 Ibf for 2 minutes Displacement of more than 2 4 mm is not acceptable Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission o
182. t which will produce an impact of 5 ft lbs 6 8 J After the test the sample shall comply with all of the following a There shall not be any visible damage to the enclosure of the unit that would result in the exposure of live parts as determined by contact with the accessibility probe illustrated in standard b There shall not be any cracking or denting of the enclosure of the unit that would affect the function of any safety controls or constructional features such as overcurrent protective devices waterseals or strain relief or result in the exposure of live parts increasing the risk of injury to persons c There shall not be any damage to the enclosure of the unit that would result in an increase in the risk of electric shock as determined by compliance with the Dielectric Voltage Withstand Test described in the Standard for Cord Sets and Power Supply Cords UL 817 and the Leakage Current Test Section 18 SS Se Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Report relative ease of installation Report if instructions pertaining to installation are complete and understandable Follow directions for installation in Instruction manual Parts shall be provided as claimed When used with specific product under maximum loading condition for 4 hours the fol
183. tage of 2000 VAC is applied between live parts and accessible metal parts without an indication of unacceptable performance 13 Accessibility of Live UL 498A An opening smaller than 1 inch 25 4 mm in an enclosure is Parts acceptable if a probe as illlustrated in the standard when inserted point first into an opening cannot be made ot touch any uninsulated live part or film coated wire 14 Temperature Test UL 498A Under normal operating conditions supporting surface and all accessible surfaces shall not attain excessive temperature as described in the standard 15 Continuity of UL 498A The resistance between the point of connection of the grounding equipment grounding means at or within the appliance and any connection other point in the grounding circuit of the appliance shall not exceed 0 1 ohms 16 Continuity Test In House Method Each product shall be tested to determine that continuity between all blades and pin of attachment plug and end terminal or receptacle of the female connector by using a digital multimeter A Ret ee eee Evaluation 17 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Servic
184. ted in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA013 US 12V Power Light Spot Light Intertek Version 7 Date August 10 2011 Page 2 of 2 Test Items Test Method Test Requirements 20 Functionality Actual Use To check if the product is able to operate as intended according to the Check instruction manual Ease of Follow directions for Report relative ease of installation Report if instructions pertaining to Installation installation in installation are complete and understandable Instruction manual Parts shall be provided as claimed 22 Ease of Cleaning Follow Instructions or Follow the cleaning instruction Removable parts shall be replace easily Wipe Gently with and not causing any safety hazards Damp Cloth 23 Continuous Actual use Under maximum loading condition for 4 hours the following shall not Operation Test occur Emission of flame molten metal or growing or flaming particles through any openings Creation of any openings in the enclosure that result in accessibility of live parts Ignition of the enclosure or functional failure Additional
185. tems to California DG EA065 US Subject to actual sample Subject to actual sample Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA024 US 3 Outlet Holiday F X Remote Control Intertek Version 6 Date August 10 2011 Page 1 of 2 Requirement Document Review S Labelling Uniform Packaging Distributor s Name amp Address City State amp Zip Packaging or and Labelling product Regulation Product Identification Country of origin NAFTA amp FTCA Sect Country Of Origin If Imported marking lf 5 imported 3 Safety The provided UL or ETL Listing safety mark shall be validated Certification Mark User Manual UL 508 Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assem
186. the product with the following Battery Contains Mercury Do Not Put in Trash Recycle or Manage as Hazardous Waste or equivalent CT and NY further require that the product with button cell batteries that contain Hg to be replaceable Product with button cells found to have intentionally added mercury that may be distributed to CT or NY shall have the batteries replaceable allowing for use of common household tools Instructions and warnings shall be provided in the user manual identifying reasonable foreseeable uses or misuses of the product It shall also include instructions regarding the installation use safety and maintenance All accessories shall be described in the user s manual and provided with instructions for proper use Shall meet label claims Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA046 US Cordless Multi Tools Intertek Version 5 Date August 10 2011 Page 3 of 4 SS 19 Workmanship i Shall have no major defects such as Cracks or breakage on provided accessories Serious
187. the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA056 US Audio Video USB Cables Intertek Version 3 Date 18 March 2010 Page 1 of 2 Test requirements Reference Method Document Review E 1 Labelling Packaging Uniform Labelling Distributor s Name amp Address City State amp Zip or product Regulation 2 Country of origin NAFTA amp FTCA Sect 5 Country Of Origin If Imported marking If imported 3 Parts Inventory Shall meet label claims 4 General and Visual Check A general cautionary and warning marking intended to inform Cautionary Markings the user of a potential risk of fire electrical shock or injury to persons shall be provided 5 User Manual Visual Check Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructi
188. the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Intertek Product Spec DG EA008 US Corded Telephone Answering Machine Caller ID Version 10 Date Aug 16 2011 Page 3 of 4 Test Item Test Method 17 Component Visual Check 18 Dielectric UL 60950 1 Cl 5 2 Voltage Withstand Test 19 Accessibility of UL 60950 1 Cl Live Parts 2 1 1 1 20 Temperature UL 60950 1 Cl 4 5 Test Mod 21 Strain Relief UL 60950 1 Cl 3 2 6 If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other without marking components The electric strength shall be adequate between telephone line and accessible parts Mains to handset 1500Vac Mains to enclosure 1000Vac Telephone line to handset 1500Vac Telephone line to enclosure 1000Vac To determine whether a HAZARDOUS LIVE part is ACCESSIBLE the jointed test finger according to test probe B of IEC 61032 Figure 14 is pushed against the enclosure or inserted through any openings of the enclosure including openings in the bottom without appreciable force Record the maximum operating temperature of enclosures and handset which shall not exceed the following requirements Enclosure 70 C Knobs 60 C Handset 50 C Strain relief shall be provided to prevent a m
189. tion and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA028 US Photoelectric Switch Intertek Version 6 Date August 10 2011 Page 2 of 3 Test requirements Test Method Requirement Principle Assembly 12 Internal Wiring Wireways shall not allow wires to come in contact with sharp points edges or moving parts 14 Cord Type and UL 773A A cord connected appliance shall be provided with an appropriate type Length Clause 8 3 and length of flexible cord per section Size 2 18 AWG Type 2 SPT 2 15 Polarization Visual Check Fuse and switches shall be connected to the un grounded conductor of the power supply Screw shell of lampholder shall be connected to the grounded conductor of the power supply be Electric Safety a et 16 Component Visual Check If listing safety report provided report any difference of component used Check in the sample and the listing report Exclude plastic material insulation material or other without marking components 17 Dielectric UL 773A The insulation and spacing shall withstand the dielectric vo
190. tion does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA057 US Universal Remote Control Intertek Version 4 Date Aug 16 2011 Page 2 of 2 Fitness for Use SS 13 Functional Check Actual Use All the major features shall be matched with the installation and use instructions and claims made on the packaging with no inaccurate or misleading statements about the product or any other user friendliness problems 14 Ease of Installation Actual use Follow the instruction to assembly and disassembly the product and comment the method of the installation Parts shall not easy to break during normal use of cleaning operations from the product Test wooden surface at a height of 3 feet 19 Appliance Actual use The remote control shall function properly with the type of Compatibility appliances stated in the user manual In case of universal remote control one model of different type of appliances as listed in the manual would be tested for compatibility 20 Rain Test In house method For outdoor use the unit are subject to the rain test for 1 2 hours No water shall enter the internal circuitry and battery A E EE Additional test 21 With Child Appealing a EA srairmear iS Tague nRIS A DEERBI meet T3 Fequiret
191. tion of the switch shall not occur A trigger switch lock on shall be located so that accidental activation is unlikely 17 Charger Plug UL 1310 When inserted in a duplex receptacle no part of the direct plug in unit cls 5 14 including an integral tab or output wiring shall interfere with full insertion of an attachment plug into the adjacent receptacle 18 Charger Plug UL 1310 The enclosure of a unit shall be capable of bring gripped for removal Cls 5 17 from the receptacle to which it is connected and the perimeter of the face section from which the blades project shall not be less than 0 20 inch 5 1 mm from any point on either blade aX Safety E E gE FANE FF TE 2A Ff 19 Dielectric Voltage UL 745 3 The electric strength of handles and grasping surfaces shall be Withstand Test Cls 15 adequate The insulation is subjected for 1 min to a voltage of 1000 V is applied between the output shaft and handles or grasping surfaces 20 Motor Reversing UL 745 3 Switches or other devices for reversing motor direction shall withstand Tests Cls 17 2 the stresses occurring when the direction of rotation is changed under running conditions with a fully charged battery per Section for 25 times No mechanical or electrical failure shall occur 21 Mechanical UL 745 3 Tools shall have adequate mechanical strength and be so constructed Strength Cls 19 1 as to withstand such rough handling as may be expected in normal use Three drops from heig
192. tive Installation ease of installation Report if instructions pertaining to installation are complete and understandable Parts shall be provided as claimed shall be replaced easily and not causing any safety hazards the claims on the user manual 30 Operating Range In house method The telephone shall not lose link and the sound quality shall not degrade significantly when the handset was used at a distance of 30 feet in door distance from the base unit Aadditionafest A IN E E EE VE INET FF fF A UE 31 Chemical amp DG EA065 Shall meet the requirements in DG EA065 Energy Efficiency e All products containing CA Prop 65 warning label will be reported as test for all FAILED electrical items to California Dollar General Shall provide signed chopped document Dollar General Toxics in Certificate of Packaging Certificate of Compliance Compliance Client requirement Toxics in Client requirement packaging Sample size 3 sets Turnaround time 7 working days Test charge 300USD For additional charge and other information of Chemical amp Energy Efficiency test for all electrical items to California please see the protocol DG EA065 US for details Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services C
193. truction Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Instruction manual shall include Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver E Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult th
194. u of testing test report can be submitted if dated within 1 year Additional Charge Item Testing Charge amp Sample Size amp Turnaround Time Turnaround time 7 working day Sample size 3 pieces Testing charge Sample size Basic charge USD 250 Additional charge Chemical amp Energy Efficiency test for all Subject to actual sample Subject to actual sample electrical items to California DG EA065 US Remark Additional samples and tests may be necessary subjected to the review by Intertek upon receipt of the sample Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA040 US High Pressure Cleaning Machines Intertek Version 8 Date August 10 2011 Page 1 of 4 Document Review 1 Labelling Packaging Uniform Labelling Distributors Name amp Address City State amp Zip or product Regulation Product Identification marking If imported Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and
195. ual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts The plug shall be 3 wire grounded type or a 2 wire polarized type If the integral blades of a plug in switch are non polarized the receptacles provided shall be non polarized polarized the receptacles provided shall be polarized grounding type the receptacles provided shall be grounding type A cord connected appliance shall be provided with an appropriate type and length of flexible cord per section Size 2 18 AWG Type 2 SP 2 Length 2 18 inch and lt 10 ft Fuse and switches shall be connected to the un grounded conductor of the power supply Screw shell of lampholder shall be connected to the grounded conductor of the power supply Electrical Safety ey Beri een ae 16 Component Check Dielectric Voltage Withstand Test Continuity of grounding connection Accessibility of Live Parts Temperature Test Strain Relief Fitness for Use Evaluation 22 Functional Check Visual Check UL 917 Clause 32 UL 917 Clause 36 UL 917 Clause 6 1 3 UL 917 Clause 26 UL 917 Clause 37 Actual Use If listing safety report provided report any difference of component used in the sample and the listing report Exclude plastic material insulation material or other without marking components The insulation and spacing shall withstand the dielectric voltage withstand test without breakdown applied between a live pa
196. uch any uninsulated live part or film coated wire 15 Temperature UL 508 Under normal operating conditions supporting surface and all Test accessible surfaces shall not attain excessive temperature rise as described in the standard 16 Strain Relief UL 508 Strain relief shall be provided to prevent a mechanical stress on a flexible cord from being transmitted to terminals splices or interior wiring 17 Stability Test UL 508 A portable appliance overturns when placed on a plane inclined at an angle of 10 degrees from the horizontal or tipped through an angle of 10 degrees from an at rest position on a horizontal plane A risk of injury to persons shall not result 18 Grounding UL 508 If a grounding means is provided whether required or not it shall be consist of an equipment grounding conductor in the cord 19 Continuity Test In House Method Each product shall be tested to determine that continuity between all blades and pin of attachment plug and end terminal or receptacle of the female connector by using a digital multimeter Fitness for Use _ Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does
197. untries Shall have valid UL or ETL Safety Agency Listing mark for USA Report Mark Verify Client Acceptable Safety Agency Listing by contacting Listing Agency with the sample s Listing Number Manufacturer Model Number and or Agency Control Number Shall be verified Use labeli CPSD HL 01057 D MTHD Visual Client acceptable safety agency CPSD HL 01057 labeling MTHD Visual CPSD EL 01090 Safety agency listing verification MTHD Verification procedure Shall indicate country of origin legibly permanently and in comparable size and close proximity to any on ae mention of country other than country in which the Country Of Origin pean 134 article was manufactured or produced Must be visible at point of purchase BUREAU VERITAS Rechargeable battery outside jacket marking Mercury Containing and Rechargeable Battery Management Act Pub L 104 142 13 May 1996 Stat 110 1333 Dollar General Certificate of Compliance Toxics in packaging Sharp points Sharp edges PHYSICAL CHARACTERISTICS Dimensions Weight WORKMANSHIP CPSD HL 01057 MTHD Visual ANSI C18 2M PART 1 2007 Section 1 4 8 1 Mercury Containing and Rechargeable Battery Management Act Pub L 104 142 13 May 1996 Stat 110 1333 CPSD GB 00001 MTHD Client requirement 16 CFR 1500 48 1500 49 modified CPSD HL 01056 MTHD Standard measure CPSD HL 01056 MTHD Standard measure DGEN 04034 US WIRELESS HEA
198. use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA027 US Clock Operated Switch Intertek Version is Date August 10 2011 Page 1 of 3 Document Review Labelling Uniform Packaging and Distributors Name amp Address City State amp Zip Packaging or Labelling Regulation Product Identification product Country of origin NAFTA amp FTCA Sect 5 Shall mark with Country Of Origin If Imported Shall have valid UL or ETL listing Verify listing by NRTL product Mark directory with the sample s listing number and model number General and UL 917 Marking shall include at least the following Cautionary Clause 43 Rated voltage Markings Rated current with watts horsepower motor current or volt amperes AC or DC Manufacturer s name or trademark Resistance only for non inductive resistance loads Tungsten for tungsten filament lamp loads Inductive for high inductive loads Pilot duty for magnet coil load User Manual Visual Check Instructions and warnings shall be provided in the user manual Important Safety identifying reasonable foreseeable uses or misuses of the Instructions product It shall also include instructions regarding the Assembly installation use safety and maintenance Instructions 6 FCC part 15 rules Visual Check FCC part 15 report shall be provided for verification if the operating frequency gt 9kHz for AC
199. uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures a Reorient or relocate the receiving antenna a Increase the separation between the equipment and receiver a Connect the equipment into an outlet on a circuit different from that to which the receiver is connected a Consult the dealer or an experienced radio TV technician for help consiueion a a T Workmanship Visual Shall have no major defects such as Cracks or breakage on provided accessories Serious scratches on the external surface Peeling of rating or caution warning label 11 Mechanical Assembly Visual Check All mechanical parts shall be securely fixed and prevented from turning 12 Internal Wiring Visual Check Wireways shall not allow wires to come in contact with sharp points edges or moving parts Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specifica
200. y associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA018 US Extension Cord Sets Version 7 Date August 10 2011 Page 1 of 2 Intertek Document Review Z To SO 1 Labelling Uniform Labelling Distributor s name amp Address City State amp Zip shall be shown on the Packaging or Regulation packaging product po Product Identification Country of origin NAFTA amp FTCA Sect Country of origin marking shall be provided and clearly indicated to the marking lf 5 ultimate purchaser of a product where it is made imported Shall have valid UL or ETL listing or equivalent Verify listing by NRTL mark product directory with the sample s listing number and model number 4 General and UL 817 A general cautionary and warning marking intended to inform the user Cautionary Cls 15 22 of a potential risk of fire electrical shock or injury to persons shall be Markings provided User Manual Instructions and warnings shall be provided in the user manual Important Safety Cls 23 35 identifying reasonable foreseeable uses or misuses of the product It Instructions shall also include instructions regarding the installation use safety and Assembly maintenance Instructions Construction Check Workmanship Visual Check Shall have no major defects such as external Cracks or breakage on provided accessories Ser
201. y of live parts Ignition of the enclosure 22 Switch Endurance Operate the switch for 100 cycles with no failure Test ee ee Additional test E 23 Chemical amp Energy DG EA065 Shall meet the requirements in DG EA065 Efficiency test for all e All products containing CA Prop 65 warning label will be electrical items to reported as FAILED California Technical information and related recommendations listed in this specification are proprietary information of Intertek Testing Services Copying is prohibited without permission of Intertek in written document This specification does not purport to include all the necessary provisions nor address all of the safety concerns if any associated with its use Compliance with this specification does not of itself confer immunity from legal obligations Product Spec DG EA039 US Transient Voltage Surge Intertek Suppressor Version 6 Date August 10 2011 Page 3 of 3 24 Dollar General Client requirement Shall provide signed chopped document Dollar General Toxics Certificate of in Packaging Certificate of Compliance Compliance Toxics in packaging Client requirement Volatile organic GC MS screening US Product with solvent based liquid eg Adhesive paints glues Substances VOC if EPA method 5000 and and etc shall not contain toxic aromatic compounds and hazard applicable 8021B doc review substances GC MS screening or US EPA method 5000 and 8021B In lie