Home
Remote Admin Guide for iPush Embedded
Contents
1. 7 CONFIGURE AUTOEXEC PROGRAMS ccccccccsecccccsecccccceccccaccccuseccccuucecccsuscccuseccccueeccuauececuusecceuuccceuausceeueuececaececuuasecs 7 CHAPTER 4 SYSTEM INFORMATION cccccccccsssssccccsscccccsccccccsccccccsceccccscccsccceccccsceccccccscsccceccscceccccccscscccesoseeees 9 LOOK UP SYSTEM INFORMATION OF WINCON 80000 00 ccc ccc cccccccecccccccccccccccccecccccuccccccauscccueccecucceceascecuesceeaenceceaes 9 CHAPTER 5 DEVICE CONFIGURATION 2 22 ccccccsssccssssscccsssccccsscccccscccccsscccccsccccccccccccsccccccsccccccsscccccccccscecccsees 10 WHAT S SUBJECT TREE OF IPUSH EMBEDDED ccccccecesscccsesecececcecesecscsevecssecscsscevstessevevsvecesseesvetesevevavesectevevsveseeseee 10 LOOK UP SUBJECT TREE AND SYSTEM NAME OF IPUSH EMBEDDED eee 11 CHANGE SYSTEM NAME OF IPUSH EMBEDDED cette c 12 CHANGE SYSTEM NAME OF IPUSH EMBEDDED 12 CHANGE SUBJECT TREE OF IPUSH EMBEDDED 12 CHAPTER 6 IPUSH esset tees tete esee tees sees esee tees esee esses eee sese ee esee eee eae eee aae 15 CONFIGURABLE ITEMS OF IPUSH EMBEDDED ettet rl 15 LOOK UP CONFIGURABLE ITEMS OF IPUSH 15 CHANGE VALUE OF EACH CONFIGURABLE ITEMS ccccccceecccccccccccccccccecccccuscccccuceccususcccuucececuuccceeuscecaueceseune
2. Edit Tag Athibute Tag Type BitInput Channel 4 Description Description Remove a tag otep 1 Select a tag in the subject tree otep 2 Click Delete Tag otep 3 Make sure you want to remove this selected tag in the confirmation dialog box followed 14 a ICE TECHNOLOGY www icetechnology com Chapter 6 iPush Configuration The tab iPush Configuration can show you the configurable items of iPush Embedded And you can edit and save the changed value of each item in this tab Configurable items of iPush Embedded There are six configurable items of iPush Embedded in this tab ListenPort the TCP IP port number of iPush Embedded listens to LogFileLevel the level of logging system works from 1 to 5 the lower number produces more details log records Default is 3 SourceReconnectTimeout the disconnected time duration in ms for starting to reconnect to up linking iPush Server Default is 12000 12 seconds Log File Expiration set the maximum total size in MB of log files and time duration in day for expiration Default is 10 MB 7 days Tips Please Check lOModule Programming Guide and Remote Administration Guide for advance configuration information Look up configurable items of iPush Embedded Just click Refresh in the tab lt iPush Configuration gt to show the current values as figure below 15 a ICE TECHNOLOGY www icetechnology com iPu
3. Just click Refresh in the tab Device Configuration to show the information as figure below On the left side of the tab you may see the subject tree without root WC8K and System Name Click node to expand the subject tree iPush Embedded Remote Administration for Wincon 8S000 E n x Connection Help Autoesec Pro System Infor Device Cont 87 Configu User Manage System Chobits ov Tagh H SubCroup Add Group Add Tag fe SLOT2 E SLOT3 Delete Group Delete Tag pe SLOTS SLOTS p SLOTS BLSLOT Refresh i 8077 Upload to Winons000 Connected 2 On the top of right side may see current system name of iPush Embedded a ICE TECHNOLOGY www icetechnology com Change system name of iPush Embedded otep 1 Edit the system name in the System Name text box otep 2 Click Upload to WinCons0DO to save change to WinCon 8000 Change subject tree of iPush Embedded You may add rename or remove a group and add edit or remove a tag with the subject tree And make sure you have clicked Upload to Winongan to save the setting to WinCon 8000 after any change Add a group otep 1 Select a SLOT or a group in the subject tree Step 2 Click Add Group otep 3 In the dialog box followed input the new group name and click OK New Group Name Then you have added a new node group to the nod
4. a ICE TECHNOLOGY www icetechnology com ICE iPush Communication Server Embedded Remote Administration Guide By ICE Technology Corp Sept 23 2004 Ver 1 3 E Mail service icetechnology com Tel 886 2 23961880 Fax 886 2 23961881 Copyright 2004 ICE Technology Corporation All Rights Reserved iPush Server is the registered trademark of ICE Technology Corporation a ICE TECHNOLOGY www icetechnology com Table of Content CHAPTER T INTRODUCTION rera e Cu daka eb ou quss ao Ta ruta Con aug Gc Ue paya YF x Cos aes kae pea M e vea ee a ek T ebas as 3 ABOUT IPUSH EMBEDDED REMOTE ADMINISTRATION eere ds 3 ABOUT THIS IPUSH EMBEDDED REMOTE ADMINISTRATION GUIDE 3 ABOUT IPUSH EMBEDDED 3 CHAPTER 2 START REMOTE ADMINISTRATION ccccccsssscccsssccccsssccccsscccccscccccsssccccccccccccscccscssccccescccseeess 5 START REMOTE ADMINISTRATION FOR 8000 5 CONNECT TO IPUSH EMBEDDED IN 8000 5 DISCONNECT FROM IPUSH 6 CHAPTER 3 AUTOEXEC PROGRAMS u i u ccccccsccccssscccsssscccsscccccscsccccscccccccccccccsccccccccccccsscccccsccccccscccccssccccescccsseecs 7 WHAT S AUTOEXEC PROGRAM FOR 8000
5. iPush Configu User Manage Program 1 Program 2 At most 10 programs can be Program 3 specified to execute automatically when system Program 4 started And there is none dependency between Program 5 programs Program 6 Program 7 Program 3 Program 9 Program 10 Refresh Save setting Connected 4 You may change working tab by clicking the captain of tab you want We will give you the details of each tab in later chapters of this document Tips User will Prompt to enter IP address and port number at startup default port number of WinCon 8000 is 6000 maybe vender will make custom adjustment like 9000 or other number Connect to iPush Embedded in WinCon 8000 otep 1 Select Connect from the Connection menu Step 2 Input the IP address Port of iPush Embedded WinCon 8000 you want to connect and User ID wc8k default Password wc8kadm default then click Conect ar ICE TECHNOLOGY www icetechnology com Connect to server X IP 152 162 0 182 Port 8200 User ID week Password The status bar of Remote Administration will show Connected if connected successfully Disconnect from iPush Embedded otep 1 Select Disconnect from the Connection menu The status bar of Remote Administration will show Disconnected if it disconnected from iPush Embedded successfully ar ICE TECHNOLOGY www icetechnology com Chapter 3 Aut
6. Click Save Setting the changes will be updated to WinCon 8000 a ICE TECHNOLOGY www icetechnology com Chapter 4 System Information The tab System Information gives you the system information about WinCon 8000 you connected Look up system information of WinCon 8000 Just click to show the information as figure below On the left side of the tab you may see the I O modules have been plugged into slot 1 7 On the right side you can see the information about hardware firmware operating system and SDK iPush Embedded Remote Administration for WinCon 8000 bx Connection Help amp utaexec Pro RMS EMI Device Conti iPush Configu User Manage SLOT 1 15056 Serial Humber 48 55 60 3 0 0 EA SLOT2 18053 MAC address 00000000000 SLOTS 1307 EEPROM Size 16K bytes sLOT4 L8000 Fish Memory Size SLOT 5 18000 OS Version Windows NET 4 1 01 01 01 SLOT6 L8000 OS Imag 22616504bytes SLOT 7 T 2000 WinCon SDE Version WinCon SOE 1 2 0 Connected 2 a ICE TECHNOLOGY www icetechnology com Chapter 5 Device Configuration The tab Device Configuration can show you the subject tree of iPush Embedded for real time message addressing to and from devices And you can add edit and delete the node Group Subgroup or leaf Tag of the subject tree in this tab What s subject tree of iPush Embedded For sending re
7. Device at WinCon8000 can use sign to set READ WRITE DEFAULT Permission as fellow READ WRITE DEFAULT Add New User x UserID Password Re enter Password Ea Read Permission Wrte Permussion Default Perruszion ma User don t have to input the system name or subject string here For Example Chobits Here READ Permission on WinCon800 For an i8053 Digital input Module at WinCon8000 SLOT 2 and user want to RAED the input data ONLY please set READ Permission as Fellow READ WC8K Chobits 8053 2 WRITE DEFAULT 2 ar ICE TECHNOLOGY www icetechnology com Add New User x UserID Password Re enter Password Read Permussion WC8K Chobits 8053_2 Write Permission Default Perrussinn Cu WRITE Permission on WinCon800 For an i8056 Digital Output Module at WinCon8000 SLOT 1 and user want to WRITE the output data ONLY please set WRITE Permission as Fellow READ WRITE WC8K Chobits 8056 1 DEFAULT Add New User x User ID Password Re enter Fassword Read Perruszian Write Perrussion Default Perrssion 22 a ICE TECHNOLOGY www icetechnology com RAED and Monitor Permission on WinCon800 For an 18056 Digital Output Module at WinCon8000 SLOT 1 and user want to WRITE the output data and READ the writing result please set RAED WRITE Permission as Fellow READ WC8K Chobits 8056 1 WRITE WC8K Chobit
8. al time message to and receiving real time message from I O devices of WinCon 8000 with iPush Embedded ICE uses the subject tree hierarchy for message addressing message destination There is one default subject tree designed by ICE for user s convenience but you may change it as you want The subject hierarchy is constructed in format below WC8K System Name gt lt Device gt _ lt Slot gt lt Group Name gt lt Tag Name gt Node Group Name can be omitted Multiple Group Name nodes are allowed A tag can represent a bit or a group of bits of I O device in WinCon 8000 I O Module of iPush Embedded gives the words above in blue it will auto detect the device model and slot number from WinCon SDK And user can assign the words above in red ALL THE NAMING ARE CASE SENSTIVE So a legal subject name may like gt WC8K Chobits 8056 4 SuperGroup SubGroup Tag9 gt WC8K Lucifer 8064 2 gt WC8K Venus 8024 1 Analog0 10 ar ICE TECHNOLOGY www icetechnology com Where Chobits Lucifer and Venus are system names SuperGroup SubGroup and ICE are group names Tag9 TagA and Analog0 are tag names You may send publish or receive subscribe real time messages with such subject tree hierarchy in your own iPush client application Please be ware of subject name is case sensitive and has the 224 byte long limitation Look up subject tree and system name of iPush Embedded
9. e you selected Rename a group Step 1 Select a group in the subject tree Step 2 Click Rename Group Step 3 In the dialog box followed input the new group name you want to change and click OK Eename Group 12 a ICE TECHNOLOGY www icetechnology com Remove a group otep 1 Select a group in the subject tree otep 2 Click Delete Group otep 3 Make sure you want to remove this selected group in the confirmation dialog box followed Add a tag otep 1 Select a SLOT or a group in the subject tree otep 2 Click AdaTeg otep 3 In the dialog box followed input the attributes of new tag and Click OK Name give the name of this new tag Type according to the I O device type of WinCon 8000 there are 6 types you can input here Digitallnput DigitalOutput Bitlnput BitOutput Analoglnput and AnalogOutput Channel input the I O device channel bit of WinCon 8000 you want the message to send to or receive from represents the group of all bits Description input any description for this tag New Tag Attribute Hame Channel Description otep 4 Click OK 13 a ICE TECHNOLOGY www icetechnology com Then you have added a new leaf tag to the node you selected Edit a tag otep 1 Select a tag in the subject tree otep 2 Click FditTag otep 3 In the dialog box followed edit the attributes you want to change and click OK
10. edded is featured with the properties described below Active Push iPush Embedded adopts the message driven mechanism That is when receiving a message from the I O modules iPush Embedded will automatically push the data to subscribers with no pulling efforts by request e Bi directional Real Time Communication iPush Embedded can immediately send a message to the subscribers The subscribers that receive messages are also able to send control commands a ICE TECHNOLOGY www icetechnology com modules within milliseconds e Massive Messaging iPush Embedded is able to send a great amount of data including meters status and alerts that are received from the I O modules e Wide Range Accessibility iPush Embedded can be accessed easily by a variety of remote devices such as PC Pocket PC and mobile phone e Massive Connection iPush Server can be installed to manage the massive connection of WinCon 8000s group a ICE TECHNOLOGY www icetechnology com Chapter 2 Start Remote Administration Start Remote Administration for WinCon 8000 B Please find the shortcut 3 or executable file RAdm exe of E dm exe iPush Embedded Remote Administration for WinCon 8000 in Windows system Double click the icon you find you will see the application as illustrated below iPush Embedded Remote Administration for WinCon 8000 Bl x Connection Help PEU wd eee Gustem Infor Device Confi
11. o it wc8k this is a administration user as administrator and user of iPush Embedded Remote Administration application You may only change the password of it the default password is wc8kadm this is a messaging user It has the full access right of subscribing all subjects and publish message with all subjects the default password is ice As an administrator you may add or delete a messaging user as you want Look up users of iPush Embedded Just click Refresh in the tab User Management to show the current users as figure below 18 a ICE TECHNOLOGY www icetechnology com iPush Embedded Remote Administration for WinCon 8000 E x tuli Connection Help Autoexec Pro System Infor Device Confi iPush Configu User ID Last Logi 2004 02 05 22 13 06 127 0 0 1 String UserID Password Add User Re enter Password Delete User Read Permission White Permission Default Permission Connected 4 Change messaging users of iPush Embedded You may add edit or remove a messaging user in tab lt User Management gt Add a messaging user Step 1 Click Add User Use sign sign and Subject name for setting THE SUBJECT STRING SETTING CASE SENSTIVE otep 2 In the dialog box followed input the new group name and click OK Add New User x User ID Password Re enter Password Read Pernussion WEEK Chobits 2053 2 W
12. oexec Programs What s Autoexec program for WinCon 8000 Autoexec programs can be auto started when WinCon 8000 boots The administrator can use tab Autoexec Programs in Remote Administration to add or remove item in the program list Configure Autoexec Programs Step 1 Change the working tab to Autoexec Programs Step 2 Click to get the current setting of Autoexec Programs in WinCon 8000 The setting will be displayed in the program list Figure below shows there is one program named IPushBoot exe set as autoexec program iPush Embedded Remote Administration for WinCon 8S000 Connection Help FERE f e ile ieee Sustem Infor Device Confi iPush Configu User Manage Program 1 Compact FlashiiceTechnologyPushBoot Program 2 At most 10 programs can be Program 3 specified to execute automatically when system Program 4 started And there is none dependency between Program 5 programs Program 6 Program 7 Program 8 Program 9 Program 10 Save setting otep 3 Add or remove the autoexec programs by editing the program list Please remember each program must be given a full path from the root directory in CE s file system ar ICE TECHNOLOGY www icetechnology com otep 4 Add or remove the autoexec programs by editing the program list Please remember that each program must be given a full path from the root directory in CE file system otep 5
13. rite Pernussion WC Chobits 8036 1 Default Permiszian o 9 a ICE TECHNOLOGY www icetechnology com User ID the name of the messaging user account Password password set of the user account Re enter Password re enter the password of the user account for confirmation Read Permission permission of the user account to receive messages from the iPush Embedded subject name Separate each by the mark if there is more than two subjects Write Permission permission of the user account to send messages to the iPush Embedded subject name Separate each by the mark if there is more than two subjects Default Permission default read permission of the user account to receive messages from the iPush Embedded subject name Separate each by the mark if there is more than two subjects Then you have added a new messaging user to iPush Embedded Edit a messaging user otep 1 Select a messaging user from the user list otep 2 Edit the user in text boxes otep 3 Click Save to save the change to WincCon 8000 Remove a messaging user Step 1 Select a messaging user from the user list Step 2 Click _ Delte User otep 3 Make sure you want to remove this selected user in the confirmation dialog box followed 20 a ICE TECHNOLOGY www icetechnology com User Permission Setting Examples Full Permission on WinCon800 If a user want to have full permission on every
14. s 8056 1 DEFAULT Add New User x UserID 8056 Password nd Re enter Password Read Permission WCSK Chobits 2056 1 Write Permussion WCSK Chobits 8056 1 Default Pertrussion i cont Multiple I O Read Write Permission For an 18056 Digital Output Module at WinCon8000 SLOT 1 and i8053 Digital Input Module at WinCon8000 SLOT 2 and user want to READ BOTH the input and output data and have write permission on 8056 at WinCon8000 SLOT1 please set RAED WRITE Permission as Fellow separate with READ WC8K Chobits 8056 1 WC8K Chobits 8053 2 WRITE WC8K Chobits 8056 1 DEFAULT 23 a ICE TECHNOLOGY www icetechnology com Add New User x User ID DIOADM Fassiyord Re enter Password Fead Permission S056 1 WCsk Chobits 8053 2 Write Permission Chobits 8056 1 Default Permission comet Send or Receive data from lOModule Tester Following condition have to meet in order to successfully read write data to I O device B USER Must have account and permission on iPush Embedded User must have account and correct permission setting discuss earlier this chapter For read or write data to I O devices with iPush Embedded B FULL subject string with correct character case For Digital Output like i8056 User must give full string length like WCS8K Chobits 8056 1 SuperGroup SubGroup Tag3 Or WCS8K Chobits 8056 1 SuperGroup TagA 24 a ICE TECHNOLOGY w
15. seeaes 16 CHAPTER 7 USER MANAGEMENT eee e eee ne rete ne teet ee etes eo tete sete sesto tees etes esset esee ees eese tes eose se sese ee sese ses eosesesessoe 18 USERS or IPUsH EMBEDDED 18 LOOK UP USERS OF IPUSH EMBEDDED eerte dd 18 CHANGE MESSAGING USERS OF IPUSH EMBEDDED eene tl 19 ar ICE TECHNOLOGY www icetechnology com Chapter 1 Introduction O t About iPush Embedded Remote Administration e iPush Embedded Remote Administration application Remote Administration for short is a management tool for ICE iPush Communication Server Embedded iPush Embedded for short Right now it runs on MS Windows 2000 XP NT ME 98 operating system And almost every edition of iPush Embedded Remote Administration serves a specified PLC controller such as WinCon 8000 of ICPDAS Co LTD http www icpdas com About this iPush Embedded Remote Administration Guide This Remote Administration Guide illustrates how to use iPush Embedded Remote Administration application for WinCon 8000 You may find the last updated version of this document from the web site of ICE Technology Corporation http www icetechnology com About iPush Embedded iPush Embedded is an industrial edition of ICE iPush Communication Server iPush Server for short which is the first leading platform of MOM Message oriented Middleware developed by ICE Technology Corp iPush Emb
16. sh Embedded Remote Administration for WinCon 8000 Connection Help Autoexec Pro System Infor Device Conti User Manage SourceReconnectTimeout Edit Selected Item Log File Expiration Size MB Upload to WinCon3000 Connected 4 Change value of each configurable items For ListenPort LogFileLevel SourceReconnectTimeout SourceAddressO0 SourcePort0 otep 1 Select any item you want to change in the list otep 2 Click Edit Selected Item otep 3 In the dialog box followed input the new value of the selected item and click OK Edit SourceReconnectTimecut otep 4 Click Upload to WinCons0DO to save the setting to WinCon 8000 after any change a ICE TECHNOLOGY www icetechnology com For Log Files Size and Expiration Days Step 1 Edit the text box of Size or Days in the Log File Expiration section Step 2 Click Upload to WinCong000 to save the setting to WinCon 8000 after any change 17 a ICE TECHNOLOGY www icetechnology com Chapter 7 User Management The tab User Management can let administrator manage the users of iPush Embedded Users of iPush Embedded There are three kinds of users for iPush Embedded system reserved user administration user and messaging user And there is three default users as descript below this is system reserved user owned by I O Module in WinCon 8000 So please do not make any change t
17. ww icetechnology com Wrong CASE subject string setting will NOT work like WC8K CHOBITS 8056 1 SUPERGROUP TAGA or wc8ak chobits 8056 1 supergroup taga is WRONG B Transmit Data Type Name and Value must match with I O Device For Digital Output device like i8056 for subject string control individual tag may look like WCS8K Chobits 8056 1 SuperGroup SubGroup Tag3 Must Provide With B Property BOOL B Name BitOutput B Value TRUE or FALSE UPPER CASE ONLY For Digital Output device like i8056 for subject string control whole module may look like WC8K Chobits 8056_1 SuperGroup TagA May Provide With B Property INT or BYTE B Name DigitalOuput B Value 0 65535 for INT 0 255 for BYTE 25
Download Pdf Manuals
Related Search
Related Contents
Corrigo E - Manuel d`utilisation Curtis RMW1112 Guía de administración del servidor Sun Fire V125 ジョグティーチ RCB-J 取扱説明書第2版 User Guide for Patients PROFICIENT ONE N° 2862 ASSEMBLÉE NATIONALE Read the User`s Guide - BeBOP (Berkeley Benchmarking and Tanaka TBC-422C User's Manual APC BACK-UPS RS 800 User's Manual Copyright © All rights reserved.