1. Change User Code All users of the alarm system can change their own Access code number gt To change your Access code proceed as follows 1 Enter Access code COC os ous YES to Arm E m705 85 08 0 5 0 z MENU for Ortions 2 Enter t gt EADS Enter new code DDOD 3 If the code is 4or Sdigits press the key to accept ae Re enter new code DODAO 5 The keypad will sound an acceptance tone ifthe new Access code was accepted If you hear an error tone low please repeat from step 1 View Log LCD Only The control panel has an Event Log which stores all system activity i e users entering their codes to arm and disarm the system alarm events faults etc Each eventis time and date stamped gt To view the E ventL og proceed as follows 1 Enter Access code DDD VES to Arm HEHU for OFtions 2 Enter emC6 gt Event Type Event Type showing pe Text ee A FA Aud 82 Alm ee li I6 ESEA iia Sle a Alarm Type amp Zone No partions Tine ay ne Day Abi Press Gea to toggle ta information displayed 4 Press to scroll up and down through the log Press to when finished Abort Communications This option aborts any communications to the Alarm Receiving Centre gt To Abort Communications proceed as follows 1 Enter Access code DDD anes rom VES to Arm 2 mgb Sdo om z MEHU for Options 2 Enter EDD E Service O Ready Premier 816 17i3e 21 29 64 3 The keypad
2. 12 816 832 nstallation Manual Changing to another Partition Normally the remote keypad that you use will be assigned to a particular partition and therefore the zone and status lights will indicate information relevant to the assigned partition However you can temporarily switch the remote keypad to a different partition so that the zone and status lights indicate the information relevant to the partition that you have selected Whilstin this mode you can also use your Access code to armAisarm the partition you have selected providing you have access to the selected partition In order to use the cross partitioning feature it is recommended that the system is configured as follows e Cross partitioning mustbe enabled see page 37 e The user mustbe assigned to multiple partitions e The user should be set for Local Partition Access Only see page 66 e The remote keypads should only be assigned to a single partition gt To change to another partition proceed as follows 1 Press ms oe AREA ARMED gt mo ED 8 8 om 17 35 34 28 04 2 Enter partition D e g Press C2 to select Partition 2 Premier S16 17 35 38 25 84 The remote keypad will now indicate information relevant to the selected partition TOGOG bebo Service O Ready cS After changing to the selected partition the remote keypad will only remain in the selected partition for 10 seconds after the last key press However if an
3. Access code is entered whilst the remote is in this mode the remote keypad will remain in the selected partition for 1 minute after the lastkey press Bypassing Zones Manually Bypassing Zones Bypassing a zone prevents it from causing an alarm pA After manually bypassing a zone the bypass will remain in place untl the zone is manually unbypassed The bypass mode will time out if no key is pressed for 6Oseconds 24 hour zones cannot be unbypassed if they are violated gt To manually bypass zones proceed as follows 1 Enter Access code DDD VES to Arm Rooy HEHU for OFtions 2 Press Bypass Zone 8G NOHWE BYPASSED The Ready light will flash quickly 3 Enter the zone number DOD e g Enter OD t select Zone 2 Bypass Zonet BZ Zone 42 Burassed 4 The selected zone is now bypassed Repeatstep 3 to bypass additional zones ODORO SEOC on Service O Rexey sum Oams Service O Roay 5 Once the selected zones have been bypassed press to Away am to Stay am to retum to the normal disarmed state cS If the Quick Bypass feature is enabled see page 41 you can omitstep 1 from the above procedure When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8 16 Plus or LCD remote keypad then the Bypass light will also illuminate Unbypassing Zones To manually unbypass zones perform the manual bypass procedure on a zone thatis a
4. CE Installation Manual ssue 1 Tex Designed to Perform Premier 412 816 832 nstallation Manual O perating the Alarm S ystem 5 Operating the Alarm S ystem Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the arming and disarming methods covered in this section Access Codes e If you make a mistake whilst entering your Access code simply enter the correctAccess code Arming amp Disarming the Alarm System Checking if the System is Ready to Arm To help prevent faults during arming a Ready light has been provided on each keypad The Ready light works as follows e Ifthe Ready lightis on steady then the alarm system is ready to be armed e Ifthe Ready lightis flashing then the alarm system has bypassed zones and r Force Armable zones that are violated check these zones before proceeding e If the Ready light is off then one or more zones are violated either secure or bypass these zones before proceeding The keypads will display the zones that are violated zone l Active Front Door zone 44 Active Patio Doors Active zones are scrolled in sequence on LCD keypads mebbGbasobox Service O O Ready Active zones are indicated by the relevantzone lights on LED Keypads A If any unbypassed zones that are not enabled for Force Aming are violated at the end of the exit delay this is termed an exiterror and the alam system will go into f
5. Disarming when not in Entry gt To disarm the alarm system when not in entry proceed as follows 1 Enter Access code DDD ae Pe MEHMU for OFbions mn O wr HO to Disarm 2 Press Press fon pe Premier 816 STILTS 17 30 21 28 04 3 The Armed light will tum off The alarm system is now disarmed A If the system only has one partition you will not have to perform step 2 If the Quick Disarm feature is enabled See page 41 and the system is Stay armed you can omit step 1 from the above procedure Dis arming after an Alarm To disarm the alarm system after an alarm proceed as follows 1 Enter Access code DDD Master Bedroom 1 21 10 56 28 Zone 03 Active Haster Bedroom 2 The system is disarmed and the keypads display the source of the alarm mO6 G8 65646 Amad Service O Ready The system must now be reset before you can am again see page 75 for details on resetting alarms Auto Stay Arming If your installer has enabled the Auto Stay feature the system will automatically Stay am if the entry amp xit zone front door is notactivated whilst attempting to Away arm the system gt To auto Stay arm your alarm system proceed as follows 1 Enter Access code DDD VES to Arm HEHU for Ortions Press C ce ie Please Exit mo 668955 6 mom 17 30 21 28 84 The Armed lightwill flash and the exit tone will sound AamO OO OO000 O O OAred Service O W Ready 3 Do NOT leave the
6. LCD remote keypad then the Bypass light will also illuminate Quick Bypass and Arm The Quick Bypass and Arm feature allows you to Bypass a predefined group of zones and Away or Stay arm the system The alarm system has up to four groups see page 290n programming bypass groups gt To Quick Bypass a group of zones and Away arm proceed as follows 1 Enter bypass group D Zones AamO O O O O O O O O OArmed Premier 816 15 30 56 25 a4 Press Please Exit s 15 30 56 25 a4 The Armed and Ready lights will flash and the exit tone will sound Service O Ready 2 Press Zones atm O O O O O O O O Wama Service O Ji Ready 3 When the exittone stops the system is Away armed with the selected group of zones bypassed gt To Quick Bypass a group of zones and Stay arm proceed as follows 1 Enter bypass group CGD ion cE ae Premier 16 ee an gis so cay 19 30 56 25704 2 Press pee ca ee Premier 816 EE Oe eS Oh ot 19 30 56 25704 The alarm system will arm immediately and the Armed and R eady lights will flash 3 The system is Stay armed with the selected group of zones bypassed PA The Quick Arm feature must be enabled to use this feature see page 41 Reset Alarms This function is used to reset any standing alarms and service faults Itis also used to resetdetectors with a latched alarm indication e g Smoke Detectors gt To ResetAlarms proceed as follows 1 Enter Acc
7. ail set state intemal alam If programmed by the installer the external bell will also sound Enter a valid user Access code to silence this alarm A zone will only be armed when ALL associated partitions are armed but will be disarmed when ANY associated partition is disarmed Away Arming The Away arming mode is normally used when leaving the premises When the system is amed in this mode all detection zones assigned to your partition s will be armed The Ready light must be on steady before the alarm system can be Away armed gt To Away arm the alarm system proceed as follows 1 Enter Access code DDD fare and VES to Arm Ee mobs Sod om zy MENU for Ortions 2 Press Press he iy Please Exit 066600666m 17 30 21 28 84 The Armed light will flash and the exit tone will sound Service O Ready 3 Leave the premises when the system has armed the exit tone will stop The system is now Away armed cS If the Quick Arm feature is enabled see page 41 you can omitstep 1 from the above procedure Stay Arming The Stay arming mode is normally used when the premises will be occupied When the system is armed in this mode all Interior detection zones assigned to your partition s will be bypassed Before Stay arming check the following e Secure or bypass any perimeter zones thatare violated e Ensue no unintentionally perimeter zones are bypassed e Ensure no perimeter Force Armable zones are violated unint
8. ary Tamper 3 Auxiliary PA 5 Bell Tamper UK Bell Module Date or Time Lost Zone Tamper Trouble Press to view zone number Keypad TamperRemoved Press D to view keypad number Equipment Faults Press to view fault type lights 1 Sindicate Output 1 Fault Output 2 Fault Siren Bell Fault 2 Wire Smoke Sensor Fault Auxiliary Fuse Failed Battery Fault Service Timer Zone Soak Test Failed Com 1 Fault or Fail To Communicate Service Faults Displayed on LCD Keypads Fault Condition AC Fail AC Fail Line Fault Telephone Line Fault Smoke Alarm CZhla 2 Wire Smoke Alarm Box Aux Tamper Box Tamper Aux Tamper Auxiliary Tamper Aux Input Auxilir 3 Tanper Auxiliary Tamper UK Bell Module Bell Tamper Bell Tam per UK Bell Module Aux PA Alarm Auxiliary PA Aux Input DateTi me Loss Date or Time Lost Tanrer Zone gt l Zone Tamper rouble Tanrer KFeyrad gt 1 Keypad TamperRemoved Qubeut 1 Fault Output 1 Fault Qubeut 2 Fault Output 2 Fault Siren Fault Siren Bell Fault Smoke Sern Fault 2 Wire Smoke Sensor Fault Aux Fuse Fault Auxiliary Fuse Failed Battery Fault Battery Fault Service Resuired Service Timer Zone Soak Test Failed Coms Fault Com 1 Faultor Fail To Communicate 76 INS159 Premier 412 816 832 nstallation Manual Operating the Alarm Syst
9. dged the Service light will revert to steady yellow and the alarm system can be armed The Service light will remain steady yellow until all faults have been cleared AC Fail and Telephone Line Fault can each have a delay programmed The Service light will turn steady yellow immediately on either of these faults but no Service Fault Alarm transmission or audible alarm will occur unless the delay expires cS If your installer has disabled AC fail acknowledgement the Service light will flash rapidly during an AC fail condition The system can be armed without requiring acknowledgement of this fault Acknowledging a New Service Fault gt New service faults can be acknowledged as follows 1 Enter Access code DODDO pn Fa E YES to Arm PE ne ae MENU for Options 2 Press D 7 ee System Faults i Da se Press Menu Feset Line Fault Fress Henu Reset The keypad will display all Service Faults 3 Press Or Gs to acknowledge the faultand retum to the normal disarmed state View Service Faults gt S tanding faults can be viewed as follows 1 Press the key followed by the lt 2 key 2 The keypad will display any Service Faults see tables 3 On completion press the key Service Faults Displayed on LED Keypads Fault Condition AC Fail Telephone Line Fault 2 ire Smoke Alarm Box Tamper amp Auxiliary Input Press to view type lights 1 5indicate 1 Box Tamper 4 Auxiliary Tamper 2 Auxili
10. em Anti code Reset This feature is normally used in the UK where users are not permitted to reset the panel following a communicated alarm However the user can reset the panel after entering a unique remote reset number which is supplied by their installer or ARC gt To perform an Anti code R eset proceed as follows 1 Enter Access code DDD ie ae VES to Arm m0 68660886 Om ae MEHU for Options 2 Press EGD Nan Goel Quote Code gt 4555 29 085 805 55 oom Enter Rer lap mmo O 6 game Bee The keypad will display a randomly generated 4 mmo 6 Orme aye Pe Ronsy digit Code mo orm Wi Ready Contact the ARC to obtain a Anticode Reset number Enter the Anti code Resetnumber given to you by the ARC DODD If the code is accepted the keypad will sound an acceptance tone and the system will reset and retum to the normal disarmed state Toggle Chime On and Off When a zone is enabled for Chime the keypad will generate a Chime tone every time the zone is violated This function allows you to turn the Chime feature on and off gt To toggle C hime on and off proceed as follows 1 Enter Access code CCC VES to Arn HEHU for Ortions 2 Press ne nes Premier 816 ees eek eR Ce 17 30 21 28 04 3 If Chime was off it will tum on and the keypad will sound the Chime tone If Chime was on itwill turn off and the keypad will sound the acceptance tone
11. entionally gt To Stay arm the alarm system proceed as follows 1 Enter Access code DDD pem nee VES to Arm 2 398 0m MEHU for Getions 2 Press oon oc Premier 316 968600806 17 30 21 2804 The alarm system will arm immediately and the Armed light will flash Service O Ready 3 The system is now Stay armed A If the Quick Am feature is enabled see page 41 you can omitstep 1 from the above procedure If the system is fited with a Premier RKP16 Plus then the Stay light will also illuminate when the system is Stay amed INS159 71 Operating the Alarm S ystem Premier 412 816 832 nstallation Manual Cancelling the Arming Process gt To cancel the arming process during the exit delay 1 Enter Access code DDD as ee HEHU for Ortions mo O mom HO to Disarm 2 Press Press Pe k Premier 816 Bape sia o 17 30 21 278 04 3 Arming has been cancelled and the alarm system is now disarmed cS If the system only has one partition you will not have to perform step 2 Disarming During Entry gt To disarm the alarm system during entry proceed as follows 1 Enter the premises via the designated entry point the entry tone will sound Proceed directly to the remote keypad 3 The entry tone will stop and the Armed light will tum off The alarm system is now disarmed pA Ifa valid Access code is notentered before the end of the entry delay an alam will occur
12. ess code DDD m y YES to Arm ae E E MEHU for OFbions 2 Press GeO Press ni oe rt Premier 816 eee eee 17 30 21 28 04 3 The keypad will bleep and the alarm system will reset all latching detectors and attemptto clear any standing Alarms or Service F aults Last Alarm Log The control panel has a memory that stores the zones that caused an alarm when the system was lastarmed gt To view the alarm memory proceed as follows 1 Enter Access code DDD ies ae ae VES to Arm ane page ices on HEHU for Ortions 2 Press Ge Zones reOOb OG SSO Om Last Alarm From zone BS Last Alarm From zone Be The keypad will display the zones that caused an alarm when the system was lastarmed service O JW Ready 3 Press to retum to the nomal disarmed state INS159 75 Operating the Alarm System Premier 412 816 832 Installation Manual Service Faults The response to a Service Fault condition is programmed by the installer butis normally limited to the keypad buzzer To silence the Service Fault alarm enter your Access code A flashing Service light indicates a new fault condition The alarm system cannotbe armed whilsta new fault exists The Service light will remain flashing until the new fault is acknowledged after which it will revert to a steady yellow and the alarm system can be armed The Service light will remain steady until all faults have been cleared After a new Service Fault has been acknowle
13. itched to OV ESL429CT System Sensor 2100TS Onboard Communicator Protocols Dialling Formats REN Approval EN50136 1 1 amp EN50136 2 3 Pulse Format Express Format FastFormat ContactID SIA Level 2 3 Pager and Mobile Phone Pulse or DTMF 1 CTR21 DPT TE 001 The inbuilt communicator complies with the requirements of EN50136 2 3 EN50136 1 1 and are suitable for use in systems designed for use with ATS levels 1 or 2 and environmental class 1 or 2 i e systems using notification options up to and including 2B With the PSTN functioning normally the ATS will comply with the required performance levels subject to the ARC being suitably equipped Note These units may be used for Downloading Remote Servicing or SMS text messaging purposes in systems at ALL security grades Environmental Operating Temperature Maximum Humidity ENC Environment Dimensions 10 C to 55 C 14 F to 131 F 95 non condensing Residential Commercial Light Industrial or Industrial Physical Small Plastic Enclosure 282mm x 225mm x 80mm Large Plastic Enclosure 305mm x 405mm x 100mm Small Metal Enclosure 305mm x 310mm x 85mm x 2mm steel Large Metal Enclosure 305mm x 405mm x 100mm x 2mm steel Weight Small Plastic Enclosure 1 7 amp g Large Plastic Enclosure 2 kg Small Metal Enclosure Sg Large Metal Enclosure 5 amp g 78 INS159
14. lready bypassed e 24 hour zones cannot be unbypassed if they are still violated e Ifthe Reinstate Bypassed Zones on Disarm option is enabled see page 37 all zones will automatically be unbypassed each time the system is disarmed Group Bypass The Group Bypass feature allows you to bypass a predefined group of zones The alarm system has up to four groups see page 290n programming bypass groups 74 INS159 Premier 412 816 832 nstallation Manual Operating the Alarm System gt To Bypass a group of zones proceed as follows 1 Enter Access code DODDA VES to Arm HEHU for OFLions 2 Enter bypass group GD followed by rts ret Bypass Zone BE a edad aaa oe Zone 83 Burassed Burpass Zone BE Zone 84 Burassed The keypad will display the bypassed zones If required zones can be added or removed from the group by entering the required zone number DO e g Enter OD to add Zone 5 Bursss Zone AS zone 83 Bursssed Bursss Zone 85 zone 4 Bursssed Bypass Zone 85 zone 85 Bursssed 4 The selected zone is now bypassed Repeatstep 3to bypass additional zones 25 5 Once the selected zones have been bypassed press to Away am to Stay am to retum to the nomal disamed state PA If the Quick Bypass feature is enabled see page 41 you can omitstep 1 from the above procedure When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8 16 Plus or
15. partitions In order to use these procedures the following requirements mustbe configured e The alarm system must be split into one or more partitions e Your Access code must be assigned to more than one partition e The keypad that you use to operate the alarm system mustbe assigned to multiple partitions OR your Access code is enabled for Global Access Away Arming Partitions This option allows you to Away am one or more partitions gt To Away am selected partitions proceed as follows 1 Enter Access code DDOD fe ae mee YES to Arm Naas Sie egies Sp HEHU for OFtions 2 Press Zones AamO O O O O O O O O OaArnmed YES to Arm o E Ares 7 wt Service The Ready light will flash quickly 3 Press CD to select eselect partitions e g Press to select Partition 2 oe YES to Arm aam O O O O O O O OArma cae DAES Area gt 2 lt Partition 2is now selected 4 Press Press Please Exit 17 30 21 2584 The Armed lightwill flash and the exit tone will sound arm O O O O O O O O Wama Service O Ready 5 Leave the area being armed when the partition has armed the exit tone will stop The selected partition s is now Away armed PA If the Quick Am feature is enabled See page 41 you can omitstep 1 from the above procedure Stay Arming Partitions This option allows you to Stay arm one or more partitions gt To Stay Am selected partitions proceed as follows 1 Ente
16. premises during the exit delay At the end of the exit delay the alarm system will Stay arm Changing between Delayed and Instant Stay When Stay arming the system the delayed zones front door etc are normally delayed i e when a delayed zone is violated it will start the entry delay timer However it is possible to change the delayed zones to instant when the system is in a Stay armed mode If a delayed zone is violated when the system is in the Instant Stay mode the system will generate an alarm immediately gt To change from Delayed Stay to Instant Stay proceed as follows 1 Ensure that the system is Stay armed Press and hold the key until you hear the 2 confirmation tone IMSTAHT STAY nm 17 30 21 26 04 3 The Armed light will flash quickly The system is Instant Stay armed pA If the system is fitted with a Premier RKP16 Plus the Instant light will also illuminate 72 INS159 Premier 412 816 832 nstallation Manual 0 perating the Alarm S ystem gt To change from Instant Stay to Delayed Stay proceed as follows 1 Ensure that the system is Instant Stay armed Press and hold the key until you hear the 2 confirmation tone ne r j DELAYED STAY SE 17 38 21 28 04 3 The Armed lightwill fash slowly The system is Delayed Stay armed cy If your system is fitted with a Premier RKP76 Plus the Instant light will go off Arming and Disarming Partitions This section covers arming and disarming
17. r Access code DDD Zones AamO O O O O O O O O OAmed YES to Arm S W Reay EHU for Drtions 2 Press YES to Arm Ares gt dee Zones AamO O O O O O O O O OAmea Service O Renay The Ready light will flash quickly 3 Press CD to select eselect partitions e g Press CD to select Partition 1 Zones AamO O O O O O O O Oma YES to Arm Erne Wrs Area gt 1 Partition 1 is now selected 4 Press Zones hee CVONGIOIO LO Gr O O mans Premier 816 17 30 21 28 o4 The selected partition s will arm immediately and the Armed light will flash Service O Ready 5 The selected partition s is now Stay armed Disarming Partitions This option allows you to disarm one or more partitions gt To disarm selected partitions proceed as follows 1 Enter Access code DDD Zones AamO O O O O O O O O Amed HEHU for Orbions aie Wreney HO to Disarm 2 Press HO to Disarm Ares gt deh Zones aamOOOO00000 Service O Rea The Ready light will flash quickly 3 Press CD C to select eselect partitions e g Press to select Partition 2 HO to Disarm Aum O O O O O Oana Ares gt FEL service O Ready Partition 2is now selected for disarm 4 Press Zones aumO OOO O000 OO OArmed Press Premier 816 17 30 21 25 84 service O Ready 5 The selected partitions are disarmed INS 159 73 Operating the Alarm S ystem Premier 4
18. will bleep and the alarm system will abort all communications to the Alarm Receiving Centre INS159 77 Specifications Premier 412 816 832 nstallation Manual 6 Specifications Control Panel Power Supply Maximum Current Rating 16 5Vac 25VA transformer 16 5Vac 4OVA transformer Frequency Ripple Standby Battery Maximum Capacity Recharge Time is dependent on Battery Charge Jumper position Low Voltage Alarm Deep Discharge Cutoff EN50131 G 1997 1 Apc A Abc 50 60hz PSU Type A 5 17Ah See Safety Note 3 4 amp 5 300mA position 7AH 24hr 17AH 56hr 750mA position 7AH 10r 17AH 24hr 105V 9 5V Maximum PSU current for each output lamp Maximum ripple O6V For input voltages between 90 amp 110 the output voltage shall be between 11V amp 14V Electrical Current Consumption Quiescent Current lt 50mA Alarm lt 150mA Fuses Mains Factory Fit 23Wasc Transformer Mains Factory Fit 115Vac Transformer Battery Auxiliary Siren Data Zones Number EOL Resistor Value Panel Outputs OP 1 Supervised OP 2 Supervised OP 3 8 Siren Output Supervised Speaker Mode Bell Mode 2 Wire Smoke Detectors 125mA 250V 20mm See Safety Notes 1 amp 2 250mA 250V 20mm See Safety Notes 1 amp 2 2 5A PTC 900nA PTC 900nA PTC 900nA PTC 8 3K3 1A switched to OV 1A switched to OV 100mA switched to OV Minimum load 40 1A sw
Download Pdf Manuals
Related Search
Related Contents
ClubKart STD - PLAY iT! Amusements e manual de aplicación para micro plc lrd... lrx d00 Trident Aegis Baker WinTATS Traction Armature Testing System User Manual Sitecom Wireless Network USB Micro Adapter 300N V-Cube Installation, Operation and Maintenance Manual do Usuário . User Manual Copyright © All rights reserved.