Home
04-52-00-1 MU - Precia Molen
Contents
1. r Display device PARAMETERS DISPLAY ECO MODE allows adjusting the self termination ON Turn off the backlight after 30 seconds of inactivity weight to zero OFF Not self extinguishing backlight PARAMETERS DISPLAY BRIGHTNESS allows adjusting the backlight intensity 3 termination levels PARAMETERS DISPLAY COL OR allows setting the screen background colour 7 possible colours The choice of a colour other than white no longer allows displaying the application mode text in colour l Date and time PARAMETER DATE TIME Changing this parameter does not result in requesting a backup It occurs automatically after setting the time 6 04 52 00 1 MU bd MOLEN Operator functions F Introduction The operator functions are available from the moment power is applied to the indicator P Switching on 1 The instrument performs a self test iG Check the proper operation of the display screen no defective segments E B SDBBBBHBBBB m TET 3 The self test is completed the instrument j initiates the measurement and it is ready for kg use LJ BRIDGE 130 04 52 00 1 MU 7 Indicator i 30 P Reset The reset function allows ensuring the instrument reset when the load receiver is empty and the weight displayed is not zero This function is limited to 2 of the maximum instrument range from the initial zero in regulated use or to
2. 052 REF Mm g LJ CO 157 NUM al Llo 349 ar g LJ CO RECEHAN 13 Indicator i 30 Operator configuration F Introduction Simultaneously press keys at power on or at restart of the indicator to access the operator configuration P Configuration the parameters These parameters are accessible from the configuration menu 1 Access to the configuration menu LOGIN OPERATOR APP For MEASUREMENT and PARAMETERS menus refer to the installation guide 04 52 00 MI Fill the BRIDGE NAME parameter This parameter allows you to assign a name to the bridge of up to 10 characters Fill the LOCK MSG parameter This parameter allows choosing the message to be displayed when the presence threshold is reached and the LUCK entry is active Fill the OCK WT parameter This parameter is active when the L DEK entry is active YE S gt the weight is displayed in red on the screen NO gt the weight is not displayed Fillthe PRES THRES parameter The following two parameters are configured by the installer 6 14 Fill the LIGHT 1NAME parameter This parameter allows you to assign a name to the entry light Fill the LIGHTENHME parameter This parameter allows you to assign a name to the exit light 04 52 00 1 MU Ww N s MOLEN Lm Sa ving When the configuration parameters have been changed the backup can be done in two ways By going back to the highest level in the configuratio
3. EP 2 Press key and scroll through the various functions with the arrow keys 3 Select the HF function then confirm M 4 The result is displayed with the precision associated with high resolution during a few seconds in Legal Metrology and remains permanent outside Legal Metrology Reminder of gross 1 Switch to metrology mode GE 2 Press key and scroll through the various functions with the arrow keys 3 Select the 8 6 function then confirm M 4 The screen changes colour cyan and the result is displayed as gross weight for a few seconds in Legal Metrology and is permanent outside Legal Metrology 12 H Us MAX H Us HR Yi ids MAX MU MAX HT 04 52 00 1 MU Ww MOLEN 6 Lu Consult DSD Switch to metrology mode GP Press key and scroll through the various functions with the arrow keys Select the 15 I function then confirm M Select the READ DSI function then confirm or select function REF 2572 then confirm This reference allows identifying a bridge Select the 353 NUM function then confirm Enter the number of the record to see the keys and then confirm Remark Enter 0 to display the last recording Confirm again to display the information corresponding to the file 04 52 00 1 MU Mm 9 LJ MAX a g LI Dou Mm 9 LJ ae READ 157 a g LJ
4. HUU LJLJ a JL Indicator i 30 P Metrological screen The following information are only accessible from the metrology menu ES P k 1 Press key to view the metrological data LJ 9 The corresponding information are TS 20 MAX Maximum device range A P e level B kg Event Cnt C Ee sS0o000 3 20s 20 Flig G 1k3 ros je Ey g nL Lat SL U Ca 1 gt 0 10 04 52 00 1 MU bd MOLEN Operator Parameter F Introduction Once in the UE screen us press key DB to access the parameterization operator Then use the key D I and D keys to access the different functions available P Manually entry of a tare value preset tare This function allows you to manually enter a tare value for the net weight display from 0 to MAX 0 to cancel the preset tare 1 Select the preset tare function P T and confirm it 2 The current value of the tare weight is displayed 3 Enter the new tare value by pressing the arrow keys et Change the value of the selected digit and gl Move from one digit to another 4 Confirm the new value The value is taken as the tare value The weighing result is now viewed on the Net 04 52 00 1 MU 4 ou PT H igue g BT H BU 240 RS 2940 FA 11 Indicator i 30 P High resolution display 1 Switch to metrology mode
5. Metrology Toggles between the two operating modes a r J Keep these keys pressed to turn on the power Configuration mode indicator in configuration mode Exit a menu or the entry in progress without taking it into account m ono o Exhaust JE Allows entering configuration mode by pressing and holding the power on key m z iS Menu i Entry in a menu or take the current entry into Confirmation account o Q Directional keys Navigating in the menu or list options Indication lt gt in the help area Reset Taring 8 8 A 0 Reminder of gross 04 52 00 1 MU 3 Indicator i 30 P Navigation principle The navigation keys allow moving through menus and lists of predefined values They are active when the symbols are displayed in zone 3 of the screen See Screen page 5 A I 1 Scroll through the options at the same level or the possible values 2 Confirm the selected option or the selected value In the same case for the consultation of recorded values Scroll through the displayed information Entering an alphanumeric value I I ar 1 Reach the previous or next position in the string to enter I 2 Enter a character select next or previous character in alphabetical or numeric order NA In case of navigation error eac Exit a menu a section or option up one leve
6. a configuration value outside the legal metrology 1 Empty receiver the weight displayed is different P D from zero LI kg ha ET ee 30 D 2 Select the reset function SS i kg The weight displayed is reset LJ ITE 0 a P Taring The taring function allows storing the weight of the load in place on the receiver container as the tare value and then get the net weight of the product displayed weight current weight tare Thus the NET weight is viewed as positive when loading and negative in case of unloading 1 Place the container on the load receptor HL BRIDGE 130 D 2 Select the taring function Sa in kg The weight displayed is the net weight NET fee vel F Initial reset This reset can be done when the indicator turns on To do this when switching on the user presses button until the unit starts This zero is the reference to other reset devices 8 04 52 00 1 MU bd MOLEN 9 Reminder of gross 1 The result of a weighing is displayed in net 2 Press key B The screen changes colour cyan and the result is displayed as gross weight for a few seconds F Visualization of information Press the and keys to scroll through the available information 1 Bridge name 2 Status of lights 3 Time 4 Message from lock 04 52 00 1 MU am BRIDGE 200 pit met con 163 T PNAN 2
7. l Reach the backup option configuration mode R Go back up to the highest configuration menu level to gsc achieve the backup option Actuate the button repeatedly if necessary 04 52 00 1 MU Ww o s MOLEN Lu Screen OO LJ DDDD UDD DH IR E fogg 3888888 m e HHH d Function Title Symbol Use 1 Weight areas Gan digital data weight number of pieces calculated 2 User area Indications to the attention of the user 3 NET indication if tare taken into account Addition to unit Help area P Indication of valid keys See details below kg gt Ib Unit 5 Application mode Symbol D displayed The displayed weight is not a D metrological reference Metrological mode No symbol The displayed weight is not a metrological reference 6 W1 W2 Measuring range Range 1 or 2 is active lad The weight is unstable 20 The weight is in the zero and stable zone Ta o Confirmation of the touch of a button 04 52 00 1 MU Indicator i 30 P Help area Detail of the indication of valid keys 0 9 Numeric entry 0 2 Alphanumeric entry 1 6 Numeric entry between two specified values ex between 1 and 6 O Indication of a menu even if there is only one option ESC Output of a screen showing data in display only Ll Basic parameters r Language PARAME TERS LANGURGE Choose French or English
8. n menu by pressing key 5 NE Hu The SAVE option screen is displayed for about 1 s then the choice whether or not to confirm the modified parameters is proposed HUE HUE ND YES Select NO to return to the Select YES to return to the configuration menu without saving the configuration menu after saving up the modified parameters modified parameters 04 52 00 1 MU 15 Indicator i 30 Error messages 1 Instrument under loaded e Check the load receptor Reset to zero 2 Instrument overloaded ee er er Ser er ee er TRT Remove part of the load 3 Command denied D Example Taring with unstable weight ED ED SS es 4 Reset denied D The weight limit for this function has been lt D p gt MD p OD mm exceeded Can Remove the load and press the reset key 16 04 52 00 1 MU WO9ON3J10WVI238d MMM E E Head Office amp Plant PRECIA MOLEN B a BP 106 07000 Privas France JJ K DET PREGIA webmaster alpreclamolen com MOLEN www preciamolen com RCS 386 620 165 RCS Aubenas WORLDWIDE WEIGHING
9. ration INTOAUGHON PEN NF PFNFFRNYFFREWW FREE ehh vienes ii Configuration the parameters see eee eee eee SVING ME YE RE Y NE SC CS FN I YRR EW YN Error messages 04 52 00 1 MU ND o2 HANNO o o o o o N N Hunt denn 11 EE aR Tos 11 EE no 12 FFF CF FN FEED HNN 12 E aieiaa 13 Sa 14 Aa ai E 14 KER 15 Indicator i 30 Foreword P Documentary conventions r Pictograms Important warning concerning the safety of persons Remark concerning the preservation and proper maintenance of the equipment Note designed to Facilitate reading the manual Implement the equipment optimally r Terminology and abbreviations Menu options or parameters are noted OPERATOR OPTION 1 OPTION 2 PARAMETER or INSTALLER OPTION 1 OPTION 2 PARAMETER In this manual the functions are all executed in OPERATOR mode the notations are abbreviated as follows OPTION 1 OPTION e PRRRMETER F Recommendations For optimum equipment accuracy and preservation Do not subject the weighing instrument the scale to shocks or overloads Do not store a load on the weighing instrument discharge it as soon as the weighing has been completed Never use solvents or abrasives products for cleaning 2 04 52 00 1 MU Ww MOLEN Overall view P Keyboard ON OFF lese hel CT PRECIA MOLEN Function On Off Press and hold to turn the indicator on Application
10. w Indicator i 30 PRECIA von MOLEN i Mee ge ee MMM User manual This guide is intended for users of indicator i 30 It allows a quick start of the device For the electrical connection and installation refer to the following manuals e Wiring block diagram 04 50 00 DD Installation Manual 04 52 00 MI Before first use check the parameters for the application in configuration mode Safety For devices connected through a power outlet standard NF EN 60 950 calls for the base of this outlet to be installed near the equipment and to be easily accessed For equipment connected permanently to mains an easily accessible cut off device must be included to the permanent installation Contents Foreword Documentary CONVENTIONS sese eee eee Recommendations see ee eee eee Overall view Keyboard ects edu Neu hick E conte terse UG eee oan Navigation principle esse ee eee ee esse essere seer eenn ennenen SEON yanmar aaan o a AAE aAa reece tie cree HF FR Help area Detail of the indication of valid keys c e Basic parameters soiirci ansaa a aiaia Aai Operator functions Reminder of gr ss essere Visualization of information sse eee eee ee eee LS Gee e Te Operator Parameter I 9140 0 010110 EEE ET Manually entry of a tare value preset arel eee eee High resolution display sese eee eee eee Reminder of GLOSS sse eee eee CGOnsult DSD aat oada FERF FNAN HF WN EFFRO FF NFED HU RONYN HAF Operator configu
Download Pdf Manuals
Related Search
Related Contents
Manual do utilizador - Wiki Karat Scosche NN1642B car kit Operator Interface 第1回 - 神奈川労働局 JGC – MS-80iP (Micro System) Manuel de l`utilisateur 1652C/1653B/1654B Manual do Utilizador Tabela 8. Opções ao ligar WIND VANE & ANEMOMETER Éléments pour une didactique de la recherche d 3. Le risque perçu, l`implication, l`apprentissage et les facteurs Copyright © All rights reserved.