Home

F-Guard 1K Guardian – Fire & Security System User Manual Dear

image

Contents

1. Admin Bldg The distance the smoke detector will detect The distance the smoke detector will detect fires fires Distance 5 Please save the notecard and close it The system will initialize itself and will be ready in a few seconds F Guard 1K Guardian Fire Push Alarm 1 prims land impact How the system works Once the Fire Push alarm is triggered the alarm system will sound the main siren and will display the respective name of the device at the Main Station Furthermore the name of the avatar who pushed the alarm will be displayed via a hover text above the respective Push Alarm button The Alarm need to be reset at the Main Station If the Fire peripheral is switched off at via the Main Station the push alarm cannot be activated Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named config The group of the alarm It will only go off if an Please add here the name of a group Every item alarm in the same group was triggered need to be in the same group so that the main DeviceGroup Admin Bld station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen The name of the alarm Will be displayed on the Give the device a name station when the device triggers the alarm DeviceName Admin Bldg Please save the notecard and close it The system will initialize itself and will be ready
2. Beside the script s you will find the notecard s named _ config The group of the alarm It will only go off if an Please add here the name of a group Every item alarm in the same group was triggered need to be in the same group so that the main DeviceGroup Admin Bld station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen The name of the alarm Will be displayed on the Give the device a name station when the device triggers the alarm DeviceName Admin Bldg Distance for the ray Maximum is 10 meters Distance for the ray Maximum is 10 meters Distance 5 Please save the notecard and close it The system will initialize itself and will be ready in a few seconds F Guard 1K Guardian Alarm Siren 2 prims land impact How the system works The alarm siren will receive the active alarm from the main station and will activate an audio alarm and a blinking red light After 30 secs the audio alarm will be off the blinking light will run until the system is reset Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named _config The group of the alarm It will only Please add here the name of a group Every item need to be in go off if an alarm in the same group the same group so that the main station can recognize them The was triggered Name of the Group will also be forwarded to
3. crowbar or if an avatar force open it by running against it When the door breaks depends on the tool or how often and strong an avatar runs against It Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named _ config The group of the door Only devices in the same group will trigger if the door is broken open DeviceGroup Default The name of the door Will be displayed on the station when the device triggers the alarm DeviceName Default The time after the damage counter will reset when no damage was dealt Reset Time 10 The time after the door will autoclose Set 0 if you want to disable autoclose Autoclose 5 Who is allowed to operate the station Either Owner Group Everyone or Password Permission Owner The password Only used if activated above Password 1234 Secondary password Not required may be used if you want to open multiple doors with one key for example a master key for the janitor Secondary Password If yes door will open in the other direction Reversed No Please add here the name of a group Every item need to be in the same group so that the main station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen Give the device a name The time after the damage counter will reset when no damage was dealt The time after the doo
4. the Guardian DeviceGroup Admin Bld Receiver screen Please save the notecard and close it The system will initialize itself and will be ready in a few seconds F Guard 1K Guardian Fire amp Security System User Manual F Guard 1K Guardian Smoke Detector 2 prims land impact How the system works The smoke detector will recognize TPF and HD Emergency Fire If a fire is detected the alarm will be forwarded to the main station which will display the name of the respective device a beep at the respective detector will be activated and the LED which is normally green will switch to a red blinking one The Alarm need to be reset at the Main Station If not and the fire is off the alarm will still run If the Fire peripheral is switched off at via the Main Station the LED at the respective smoke detector will be red Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named config _contig The group of the alarm It will only go off if an Please add here the name of a group Every item alarm in the same group was triggered need to be in the same group so that the main DeviceGroup Admin Bld station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen The name of the alarm Will be displayed on the Give the device a name station when the device triggers the alarm DeviceName
5. to set the system up Please study the chapters below They will give you an introduction into each respective item of the package F Guard Guardian Main Station 2 prims land impact How the system works The Main Station has 5 buttons which will be explained below will disarm the burglar alarm system Red lock Will arm the burglar alarm system Setup Will arm or disarm the connected fire prevention peripheral If disarmed smoke detectors and sprinklers will not work and push alarm cannot be triggered Reset Will reset the Alarm system after an alarm was activated Please note if a fire is not off the alarm will sound again after reset till the respective problem fire or security is solved be forwarded after the respective delay Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named _ config The group of the alarm It will only go off if an Please add here the name of a group Every item alarm in the same group was triggered need to be in the same group so that the main DeviceGroup Admin Bld station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen The name of the alarm Will be displayed on the Give the device a name station when the device triggers the alarm DeviceName Admin Bldg Who is allowed to operate the station Group owner or everyone Permiss
6. F Guard 1K Guardian Fire amp Security System User Manual Dear customer thank you for your trust in F Guard products Please check your package The following parts should be inside No Name of the item F Guard Guardian Main Station F Guard 1K Guardian MD right Motion detector F Guard 1K Guardian MD left Motion detector F Guard 1K Guardian MD straight Motion detector F Guard 1k Guardian Alarm Siren 7 10 11 12 13 F Guard Key copier machine 14 Before you start please note e The config notecards are always in the root prims e The System works sim wide but can be extended to neighbor sims by the provided F Guard Repeater e Peripheral items can be assigned to groups and names Groups could be the name of a respective building Device name could be name of a respective smoke detector e Smoke detectors are reacting on both major fire systems in SL The TPF and the HD Emergency Fire e Sprinklers can work also with both Fire Systems As the Sprinklers cannot decide automatically on which fire they should react this needs to be adjusted in their respective vondig notecard e Alarms can only be reset at the respective Main Stations and not at the F Guard 1K Guardian Receiver screen Once the alarm is reset the alarm will also disappear from the screen F Guard 1K Guardian Fire amp Security System User Manual First steps Before you can use your system some installation is needed
7. e avatar directly takes a breaking the door pose if not switch of your AO The Halligan Tool will break the door in 1 2 try s the crowbar in 2 3 Attach the respective tool go close to the door and click in mouse look at the door You will hear a breaking sound The will be open automatically of broken Breaking a locked door will trigger the alarm system The key copier machine is used to generate keys Click on it it will ask you to enter a respective password Choose any It need to be the same as added in the respective doors After that SL will ask you for permission to attach to your avatar Choose yes The key will be attached to the center of your screen It can be moved to any other place All keys will be noCopy and noMod Means you can hand them out to your members tenants They can wear and use them hand them over to someone else but cannot duplicate or change them You as the owner can make as much keys with the same password as needed To open a door the avatar needs not have the key attached and to be in whisper range to the door Nothing else needed Just click at the door and hopefully it will open F Guard 1K Guardian Fire amp Security System User Manual F Guard RP Door Land impact depends on the respective item How the system works These doors are special doors They can be in the status locked in which only the owner of a respective door key can open it or they can be broken via a Halligan Tool a
8. in a few seconds F Guard 1K Guardian Fire amp Security System User Manual F Guard 1K Guardian Sprinkler 2 prims land impact How the system works The Sprinkler will detect either TPF or HD Emergency Fire Once the fire is detected the sprinkler glas will break and water will come out Water bullets of the respective Fire System will appear randomly and will hopefully extinguish the fire The alarm will be forwarded to the main station The Main Alarm Siren will sound The Sprinkler need to be reset via the Main station Please rezz the respective item click right on it and choose edit choose the content Beside the script s you will find the notecard s named _ config config 2 2 2 g En l nepra The group of the alarm It will only go off if an Please add here the name of a group Every item alarm in the same group was triggered need to be in the same group so that the main DeviceGroup Admin Bid station can recognize them The Name of the Group will also be forwarded to the Guardian Receiver screen Which fire should the sprinkler detect Enter Choose between HD or TPF Fire System either TPF or HD Fire Type HD The distance the sprinkler will detect fires The distance the sprinkler will detect fires Distance 5 Please save the notecard and close it The system will initialize itself and will be ready in a few seconds Either the Crowbar or the Halligan tool needs to be attached to the avatar Th
9. ion Group Set a delay time after which the station will Set a delay time after which the station will switch switch from disarmed to armed from disarmed to armed This will gives you Arm Delay 15 time to leave a building before the system is armed Set a delay time after which the station will Set a delay time after which the station will transmit transmit the alarm to the Receiver Screen the alarm to the Receiver Screen Alarm Delay 15 Please save the notecard and close it The system will initialize itself and will be ready in a few seconds F Guard 1K Guardian Fire amp Security System User Manual F Guard MD Left Right Straight Motion Detectors 2 prims land impact How the system works 3 Motion Detectors are in the package with different kind of angles Via the config notecard the distance in which the detector can detect avatars can be changed Don t worry about walls The Detector cannot look behind Walls If you rezz the detector and start to move it the detector will go into a setup mode SETUP_MODE initialized Move it in the position you want and click on the detector The hover text will be gone and you will see for a short time a red particle line which will indicates the approx detector range way If you don t click on it the detector will time out after 10 secs without saving the new position Please rezz the respective item click right on it and choose edit choose the content
10. r will autoclose Set O if you want to disable autoclose Who is allowed to operate the station Either Owner Group Everyone or Password Choose your password Secondary password Not required may be used if you want to open multiple doors with one key for example a master key for the janitor or the fire department Please save the notecard and close it The system will initialize itself and will be ready in a few seconds In any way if you have questions or you are facing problems please contact Firefighter Frimon via IM Notecard or file a ticket at our helpdesk www f guard com helpdesk