1. 120 7 128 7 131 5 128 7 E 197 12 128 7 222 52 262 05 283 0 128 7 1 3 PCI Bus Extension The PICMG 2 0 CompactPCI Specification restricts the length of a bus segment of a given CompactPCI backplane to 8 slots or less This restriction has been determined by extensive simulation and characterization and guarantees an optmimum operation of PCI compliant integrated circuits Since the inception of PCI design engineers have extended this eight slot restriction by using PCI to PCI bridge components Thanks to the use of such bridge compo nents which are put into effect on a special bridge module the implementation of Compact PCI backplanes providing more than 8 slots is possible 1 4 Distinctive Features The PEP Modular Computers CompactPCI backplanes can be distinguished according to the following distinctive features Form factor height Dimensions Number of slots Bus resolution Bus frequency Rear UO connectivity Hot swap capability Power Supply Connector Redundant power supply Flexible grounding option Fan connector Drive connector Power LED Connector PS ON Connector Reset function connector Page 4 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General 4 2 Clocks The CompactPCI system slot drives five buffered clocks while every adapter slot receives its specific clock The 6 slot and 8 slot versions are provided with indiv
2. Modular Computers CPCI Backplane Manual Manual ID 24229 Rev Index 01 March 01 2002 The products described in this manual are in compliance with all applied CE standards Preface CPCI Backplane r Revision History Manual Product Title CPCI Backplane Manual Manual ID Number nev Brief Description of Changes Date of Issue Index 01 Initial Issue Mar 01 2002 Imprint Copyright 2002 PEP Modular Computers GmbH All rights reserved This manual may not be copied photocopied reproduced translated or converted to any electronic or machine readable form in whole or in part without prior written approval of Modular Computers PEP Modular Computers GmbH DISCLAIMER PEP Modular Computers GmbH rejects any liability for the correctness and completeness of this manual as well as its suitability for any partic ular purpose This manual was realized by TPD Engineering PEP Modular Computers GmbH Page ii 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface Table of Contents FIBVISIOI FUSION ticcedenntececsaniiiiadsiudsnasiaedbad a a an EREA EA AE EDan el tin OERE ii Mn ii Table Of GREER ENN iij List Of TASS EEE ER V List OP 5 1 ege vil Pee NE eege EE ix VE 15 ERR V ix Environmental Protection Statement rrrrrrrrrrrrnrnnrrrrrrrrrrnornnrrnnnnnnnrnnnnnnnnnnnennnennnnnne ix Explanation of SymbolS serves 2 An A
3. extensions to the original guarantee are considered gestures of goodwill and will be defined in the Repair Report issued by PEP with the repaired or replaced item PEP Modular Computers will not accept liability for any further claims resulting directly or indi rectly from any warranty claim other than the above specified repair replacement or refunding In particular all claims for damage to any system or process in which the product was em ployed or any loss incurred as a result of the product not functioning at any given time are excluded The extent of PEP Modular Computers liability to the customer shall not exceed the original purchase price of the item for which the claim exists PEP Modular Computers issues no warranty or representation either explicit or implicit with respect to its products reliability fitness quality marketability or ability to fulfil any particular application or purpose As a result the products are sold as is and the responsibility to ensure their suitability for any given task remains that of the purchaser In no event will PEP be liable for direct indirect or consequential damages resulting from the use of our hardware or software products or documentation even if PEP were advised of the possibility of such claims prior to the purchase of the product or during any period since the date of its purchase Please remember that no PEP Modular Computers employee dealer or agent is authorized t
4. I O connectivity is provided on the P3 backplane connector The standard rear I O pinouts of the P3 connector are shown in the Overview chapter of this manual In addition board specific rear I O connectivity can be provided on one or more of the back plane connectors P2 P4 P5 For the pinouts of any board specific rear I O connectors please refer to the User s Manual of the relating board ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page 11 General CPCI Backplane r 3 5 Coding Keys Figure 7 Board Rack Coding Keys PCI Connectors P1 and P4 PEP Modular Computers Compact PCl systems present an advantage in the form of a special combination of coding keys They ensure proper mating of boards and backplanes in terms of volt age and function For this purpose two different kinds of coding keys have been devised which are described in the following a Additional Board Coding Key CD No key universal signalling TD Yellow 3 3 V NCR I Blue 5 0 V Red H110 present P4 LI i Main Board Keying Proper board installation is ensured by the use of colored coding keys for 3 3V yellow or 5V blue operation thus preventing incorrect installation of adapter boards This facility also pre vents confusion when hot swapping boards Additional Board Keying The function of the additional board coding key depends on the backplane Backplanes equipped with an H110 t
5. 1 2002 PEP Modular Computers GmbH Page 5 General CPCI Backplane r 2 2 System Slot Board Clock Skew This is the clock skew that may be attributed to the onboard routing differences if any of all of the PCI clocks as well as the skew specification for the type of integrated circuit driver used for clock distribution The onboard clock routing is designed to complement the propagation delays of distributing the clock to a backplane and still meet overall system skew require ments 3 Backplane Interfaces 3 1 Line Connection Both AC and DC power supply to most backplanes are connected by means of 3 pole Mate N Lok connectors marked LINE1 and on some 6U backplanes LINE2 on the backplane reverse side Figure 4 Orientation and Pinouts of AC DC Line Connectors Table 2 Pinouts of AC DC Line Connector Attention AC DC power supply units must be installed only with backplanes sys tems connected to an AC power line and DC DC power supply units with backplanes systems connected only to a DC power line Failure to comply with this warning will result in damage to your equip ment 3 2 Power Supply Connectors The AC or DC input voltages to the power supply unit and the Vo1 Vo4 output voltages from the power supply unit to the backplane are connected via a power supply connector comply ing with one of the below described specifications Note The term power supply connector is used both for the
6. 1 EN 55011 EN 55022 Immission EN50082 2 EN 61000 4 e Electrical Safety EN60950 VDE 0100 VDE 0805 6 2 Other Safety Standards UL CSA DVE NEMKO 6 3 Mechanical Compliance Mechanical Dimensions IEEE 1101 10 6 4 Environmental Tests Vibration Broad Band IEC68 2 6 e Random Vibration IEC68 2 64 3U boards e Permanent Shock IEC68 2 29 e Single Shock IEC68 2 27 7 Related Publications 7 1 CompactPCI Systems Boards CompactPCI Specification V 2 0 Rev 2 1 DIN 41612 ATX Specification e CompactPCI Power Interface Specification 2 11 R1 0 ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page 15
7. 24229 Rev 01 2002 PEP Modular Computers GmbH Page 9 General CPCI Backplane r Figure 6 ATX Power Sup ply Conector on 3U Back plane left and 6U Backplanes optional right 10 20 11 1 Table 6 ATX Connector Pinouts Function i Function Q o 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General Each CompactPCI backplane supports a 5V or a 3 3V signaling environment VIO and PCI allows for two types of buffer interfaces for interboard connection However a gradual shift to 3 3V is occurring as the semiconductor industry shifts to the lower power interface for speed and power dissipation reasons For this reason the PEP Modular Computers system back planes are also designed for 3 3V usage x 3 3 Signalling Environment Warning Using both 3 3V and 5V boards within the same system may result in damage to your equipment Please note that the presence of only one 5V board determines a 5V signalling environment The default setting is 5V When changing the signalling environment from 5V to 3 3V or vice versa please make sure that coding keys of the appropriate color are used see Coding Keys section of this chapter 3 4 Rear I O Connectivity According to PICMC CompactPCI Specification V 2 0 R 3 0 standard rear
8. 409 CP3 BP11 M Rear I O connectivity 283 0 128 7 mm 700g CP6 BP8 STD k A 222 5 262 0 mm 1 0009 CP6 BP8 DUALPCI ae Par 222 5 262 0 mm 9609 ot swap capability CP6 BP8 H110 H 110 222 5 262 0 mm 9809 System slot on all backplanes on the right 8 6U slots or down to 1 6U slot in combination with up to 14 3U slots Page 14 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General 5 Product Documentation Organization The product documentation organization for PEP s CPCI Power Supplies is as follows 1 CPCI Backplane Manual ID 24229 2 CPCI Backplane Product Documentation Guide ID 24229 Sub ID PDG 3 Specific PEP CPCI Backplane Product Documentation ID 24229 Sub ID PDnn Item 1 above is represented by this manual which provides generic information about PEP s CPCI backplanes Item 2 is enclosed with this manual for referencing to applicable CPCI Back plane Product Documentation Item 3 represents the individual product documentation for spe cific backplanes For each backplane addressed in item 2 there is a separate document available Each of the above items are maintained independently of one another whereby item 2 always reflects the current status of available product documentation 6 Applied Standards The PEP Modular Computers CompactPCI backplanes comply where applicable with the requirements of the following standards 6 1 CE Compliance e Emission EN50081
9. and specific environmental requirements This applies also to the operational temper ature range of the specific product version which must not be exceeded If batteries are present their temperature restrictions must be taken into account In performing all necessary installation and application operations please follow only the in structions supplied by the present manual Keep all the original packaging material for future storage or warranty shipments If it is neces sary to store or ship the board please re pack it as nearly as possible in the manner in which it was delivered Special care is necessary when handling or unpacking the product Please consult the special handling and unpacking instruction on the previous page of this manual Page xii 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface Two Year Warranty PEP Modular Computers grants the original purchaser of PEP products a TWO YEAR LIMITED HARDWARE WARRANTY as described in the following However no other warranties that may be granted or implied by anyone on behalf of PEP are valid unless the consumer has the express written consent of PEP Modular Computers PEP Modular Computers warrants their own products excluding software to be free from man ufacturing and material defects for a period of 24 consecutive months from the date of pur chase This warranty is not transferable nor extendible to cover any other users or long term sto
10. ce with applicable country state or local laws or regulations ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page ix Preface CPCI Backplane r Explanation of Symbols CE Conformity This symbol indicates that the products described in this manual are in compliance with all applied CE standards Please refer also to the section Applied Standards in this manual cautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the section High Voltage Safety Instructions on the following page Warning ESD Sensitive Device Caution Electric Shock This symbol and title warn of hazards due to electrical shocks gt 60V when touching products or parts of them Failure to observe the pre This symbol and title inform that electronic boards and their compo nents are sensitive to static electricity Therefore care must be taken during all handling operations and inspections of this product in order to ensure product integrity at all times Please read also the section Special Handling and Unpacking Instructions on the following page Warning This symbol and title emphasize points which if not fully understood and taken into consideration by the reader may endanger your health and or result in damage to your material amp This symbol and title emphasize aspects the reader should read through carefully fo
11. connectors receiving the backplanes power supply and the mating output connec tors of the power supply units Page 6 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General Table 3 Power Supply Connectors Connector Type Description 3 or 4 pole DIN M series female power supply connectors for power throughput to the power supply unit and a 30 32 pole DIN M24 8 female power supply connector for power reception from the power supply unit DIN 41612 Faston M4 M4 screw connection combined with 6 3mm 0 8mm strip connectors Male 20 pole ATX connector for power supply from the reverse side of the ATX backplane the ATX PSUs available on the market are provided with a matching connector DIN M Series The pinouts of the DIN M24 8 and of the ATX power supply connectors are illustrated below Note As the overall pinout of the DIN M24 8 connector installed on a 3U backplane is identical to that of both DIN M24 8 connectors installed on a 6U backplane taken together on a 6U backplane some functions are connected on the upper or on the lower connector only and there fore are not connected on the other connector see tables below Figure 5 DIN M24 8 Power Supply Connector Warning Please note that the pinouts of the DIN M24 8 power supply connectors of various power supply units dif fer Therefore please refer also to the pinout tables of the single power supp
12. ct in order to ensure product integrity at all times Do not handle these products out of their protective enclosures while they are not used for operational purposes unless they are otherwise protected Whenever possible unpack or pack these products only at EOS ESD safe work stations Where a safe work station is not guaranteed it is important for the user to be electrically dis charged before touching the products with his her hands or tools This is most easily done by touching a metal part of your system housing It is particularly important to observe standard anti static precautions when changing piggy backs ROM devices jumper settings etc If the products contain batteries for RTC or memory back up ensure that they are not placed on conductive surfaces including anti static plastics or sponges They can cause short circuits and damage the batteries or conductive circuits H ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page xi Preface CPCI Backplane r General Instructions on Usage In order to maintain PEP s product warranty these products must not be altered or modified in any way Changes or modifications to these products which are not explicitly approved by PEP Modular Computers and described in this manual or received from PEP Technical Support as a special handling instruction will void your warranty These products should only be installed in or connected to systems that fulfill all necessary technical
13. d for EMI protection pur poses 3 6 Flexible Grounding Option 3 7 Rack Dividers 3U boards may be used in a 6U rack If one or two 3U backplanes are used a middle bar is used to hold the 3U boards in place If the 3U boards are installed on a 6U backplane a split kit must be used in place of the backplane s P3 connector s For further details on split kit and middle bar separation please refer to the Racks chapter of this manual ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page 13 General r 4 PEP CompactPCI Standard Backplanes Table 7 PEP CompactPCI Standard Backplane Family CPCI Backplane Form Factor Slots Power Supply Connector Backplane Faston plugs M4 Screw Type CP3 BP4 i DIN M Series CP3 BP4 M 6 ATX CP3 BP6 ATX DIN M Series CP3 BP8 M i DIN M Series CP3 BP8 R10 11 DIN M Series CP3 BP11 M 8 DIN M Series CP6 BP8 STD 8 15 DIN M Series CP6 BP8 DUALPCI 8 DIN M Series CP6 BP8 H110 System slot on all backplanes on the right 8 6U slots or down to 1 6U slot in combination with up to 14 3U slots Table 8 PEP CompactPCI Standard Backplanes Mechanical Characteristics Backplane Special Features Size Weight CP3 BP4 80 3 128 7 mm 170g CP3 BP4 M 100 7 128 7 mm 165g CP3 BP6 ATX Rear I O connectivity 120 7 128 7 mm 270g CP3 BP8 M Rear I O connectivity 197 1 128 7 mm 400g CP3 BP8 RIO Rear I O connectivity 197 1 128 7 mm 4
14. elephony connector are marked with a red H110 key Dual PCI backplanes use coding keys for 3 3V yellow or 5V blue operation of the upper PCI bus a AC DC Keying To ensure proper connection in terms of AC DC power all PEP Modular Com Main Board Coding Key No key universal signalling Yellow 3 3 V NCR SE puters power supply units are provided py g K sla AV with special AC DC coding keys eee The coding standard is not fully defined DDAC at the moment of writing It will be Sooo implemented as soon as available meer Rack Keying OT Rack Coding Keys 1m1 Red Boards must be fitted into a Compact PCI backplane in a certain order depending on whether they are bus master boards or I O boards To this end special asymmetrically shaped coding keys can be used by the customer to ensure that the boards are inserted properly Page 12 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General With certain backplane types it is possible to select electrical isolation or connection between the bus GND and the backpanel support PE rack thanks to the fact that every second fas tening hole of backplanes is non conducting If only these fastening holes are used there is no electrical connection between GND and PE on the system bus If additional holes are used a multi point connection is created such as may be require
15. idual clock timings for the three slots on the opposite end of the backplane The remaining slots are assigned one clock for each two slots Figure2 Backplane Clock Assignment 3U backplanes The system slot provides clock signals for all the PCI peripherals Clock numbering in the system including devices An 1 2 3 4 5 on the system slot board Periph m i eral boards are provided with clock signals via the Compact PCI backplane The 8 slot backplanes are pro vided with a diode termination 6 slot 8 slot backplanes only according to the CompactPCl 8 slot backplanes only Specification Figure 3 Backplane Clock Assignment 6U backplanes Clock skew is the difference between the maximum and mini mum propagation delay of any PCI clock signal There are two different types of clock skew backplane and system slot board clock skew 1 2 3 4 The two concepts of backplane and system slot board clock skew are explained in the follow ing Clock numbering 2 1 Backplane Clock Skew A CompactPCI backplane provides the distribution of clock signals for all of the board slots in the system The differences in the trace routing and net topologies contribute to skew and also define the longest clock delay Particular attention is paid by the PEP Modular Computers sys tem design to meet overall system clock skew requirements namely through simulation test ing and qualification ID 24229 Rev 0
16. ly units for any possible differ ences to the pinouts supplied in the tables below ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page 7 General CPCI Backplane r Table 4 DIN M24 8 Connector Pinouts 3U Backplanes Function i Function L1 live connection N neutral PE earth protection INT internally connected N C not connected Warning To ensure correct 5V operation of your equipment it is necessary to connect 5VL to 5VF and OVL to OVF Ge The maximum voltage compensation is 0 25V per line Page 8 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General Table 5 DIN M24 8 Connector Pinouts 6U Backplanes Function Function Lower Upper Lower Upper Connector Connector Connector Connector 3 3VL 3 3VL 3 3VL 3 3VL 3 3VL N C 12VL N C 12VL EN N C DEG N C INT N C 3 3VL 3 3VL 3 3VL 3 3VL 3 3VL 3 3VL N C 12VL N C 12VL N C 5VL OVL L1 live connection N z neutral PE earth protection INT internally connected N C not connected Warning To ensure correct 5V operation of your equipment it is necessary to connect 5VL to 5VF and OVL to OVF The maximum voltage compensation is 0 25V per line ly ID
17. ngle on the front side of the board containing the physical slot number The following symbols provide visual indication of backplane connector and adapter board capability A System slot slot 1 O Peripheral slot slots 2 n Physically the system slot may be located at the left or right end of the backplane For simplic ity and system expandability heat sink cooling fan etc all PEP Modular Computers Com pactPCI backplanes have their system slots at the right end when viewing the backplane from the front side Warning A system master CPU should be inserted into the system slot only The peripheral slots may contain simple adapters intelligent slaves PCI bus masters or peripheral master CPU s The logical slot numbering may differ from the physical numbering on the backplanes The relation between the two numbering systems are shown in the figure below Figure 1 PEP Modular Computers Slot Numbering both 3U and 6U boards Physical slot numbering Er Oa N Oe Logical slot numbering 1 21 dd TNS EGET ID 24229 Rev 01 O 2002 PEP Modular Computers GmbH Page 3 General CPCI Backplane rc 1 2 PCB Form Factor The size of PEP Modular Computers backplanes is based upon the Eurocard industry stan dard and depends on their height format 3U 6U their number of slots and power supply unit Table 1 PCB Form Factor mm Slot Number PSU fastonma el FastonMa FE 100 7 128 7
18. o make any modification or addition to the above specified terms either verbally or in any other form written or electronically transmitted without the company s consent ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page xiii Preface CPCI Backplane r This page was intentionally left blank Page xiv 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General General ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page 1 General CPCI Backplane r This page was intentionally left blank Page 2 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane General 1 Overview The PEP Modular Computers backplane family includes 4 6 and 8 slot boards both in 3U and 6U format They can be provided with either a standard DIN M series a Faston plug M4 screw or an ATX power supply connector Backplanes are available as 32 bit or 64 bit implementa tions 1 1 Slot Assignment A CompactPCI system board backplane is composed of up to eight CompactPCI board loca tions slots with 20 32 mm center to center spacing A CompactPCI backplane consists of one system slot and up to seven peripheral slots The system slot provides arbitration clock distribution and reset functions for all boards connected to the bus The system slot is respon sible for performing system initialization by managing each local board s IDSEL signal The system slot is always marked by a tria
19. ontains information proprietary to PEP Modular Computers It may not be cop ied or transmitted by any means disclosed to others or stored in any retrieval system or media without the prior written consent of PEP Modular Computers GmbH or one of its authorized agents The information contained in this document is to the best of our knowledge entirely correct However PEP Modular Computers cannot accept liability for any inaccuracies or the conse quences thereof or for any liability arising from the use or application of any circuit product or example shown in this document PEP Modular Computers reserves the right to change modify or improve this document or the product described herein as seen fit by PEP Modular Computers without further notice Trademarks PEP Modular Computers the PEP logo and if occurring in this manual CXM are trade marks owned by PEP Modular Computers GmbH Kaufbeuren Germany In addition this document may include names company logos and trademarks which are registered trademarks and are therefore proprietary to their respective owners Environmental Protection Statement These products have been manufactured to satisfy environmental protection requirements where possible Many of the components used structural parts printed circuit boards connec tors batteries etc are capable of being recycled Final disposition of these products after their service life must be accomplished in accordan
20. r his or her own advantage Page x O 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface For Your Safety Your new PEP products have been developed and tested carefully to provide all features nec essary to ensure their compliance with electrical safety requirements They were also designed for a long fault free life However the life expectancy of your products can be drastically re duced by improper treatment during unpacking and installation Therefore in the interest of your own safety and of the correct operation of your new PEP products you are requested to conform with the following guidelines High Voltage Safety Instructions 3 Caution Electric Shock A Before installing your new PEP products into a system always ensure Warning All operations on these products must be carried out by sufficiently skilled personnel only that your mains power is switched off This applies also to the instal lation of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations with this product Therefore always unplug the power cable and any other cables which provide external voltages before performing work Special Handling and Unpacking Instructions ESD Sensitive Device LS Electronic boards and their components are sensitive to static electricity Therefore care must be taken during all handling operations and inspections of this produ
21. ra o O x For Your Safety ssd osi du Znova la Eeer xi High Voltage Safety e xi Special Handling and Unpacking Instructions cccccccccccssseeeeeeeestseeeeeeetennneeeeens xi General Instructions E e xii Two Year Warranty vedde xiii Jl OE RE NE anaes 3 TP FG ENN rer 3 12 PGB FOM E 4 1 3 PGI BIS Extension EH 4 1 4 Distinctive Features enee 4 Be e 5 2 1 Backplane Clock Skew eee 5 2 2 System Slot Board Clock SKeWw rrrrrrnrrnrrrrnrrrrrrornrrnrnnnnnnnnnrnrrnnnrnnrennrnnernenne 6 a Falat NES san 6 3 1 LINE Connection EE 6 3 2 Power Supply ele 6 3 3 Signalling Environment EE 11 3 4 Rear AO ele E 11 39 E ee 12 3 6 Flexible Grounding Option sengmmenssanannusmnnddmdemssnhauthnnt 13 3 7 GE SR EE EE 13 4 PEP CompactPCI Standard Backplanes rrrrrnrnnnrrrrrnnnnnnnnnrrrrernnrrrrrrrrnnnnrennn 14 5 Product Documentation Organization rrnrrrnnrrrrrrvrrrrrrerrrrrrrrnnrrnrnnrrnnnnnnnnnnr 15 ID 24229 Rev 01 O 2002 PEP Modular Computers GmbH Page iii Preface CPCI Backplane r 6 Applied SIAN OAS area sm ejg 15 6 1 ege 15 6 2 Other Safety STE rage 15 6 3 Mechanical Compliance EN 15 D A Environm ntal 656 v armvermvssmseoasuraumumandudumnundvsmsnsbpun 15 7 Related ee 15 7 1 CompactPCI Systems BoardS EE 15 Page iv 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface List of Tables 1 POB Form Factor MM ege ee eege deet aa 4 2 Pinouts of AC DC LING Connectot s ssssisasani o rann ho a
22. rage of the product It does not cover products which have been modified altered or re paired by any other party than PEP Modular Computers or their authorized agents Further more any product which has been or is suspected of being damaged as a result of negligence improper use incorrect handling servicing or maintenance or which has been damaged as a result of excessive current voltage or temperature or which has had its serial number s any other markings or parts thereof altered defaced or removed will also be excluded from this war ranty If the customer s eligibility for warranty has not been voided in the event of any claim he may return the product at the earliest possible convenience to the original place of purchase togeth er with a copy of the original document of purchase a full description of the application the product is used on and a description of the defect Pack the product in such a way as to ensure safe transportation see our safety instructions PEP provides for repair or replacement of any part assembly or sub assembly at their own dis cretion or to refund the original cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to PEP Modular Computers and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new or repaired items Any
23. von slava sk Vv 6 3 Power Supply Connectors mumnnesegnmpke inspekt rene 7 4 DIN M24 8 Connector Pinouts 3U Backplanes rrrrvrnnrnnvrrrrrrnnnnnnnnrrrenrrnrrnnnnnr 8 5 DIN M24 8 Connector Pinouts 6U Backplanes rrrvrrrrnnnrrrrrennnnnnnnrrrennnnnrnnnnnn 9 6 AIX Conn ctor PUNO EE 10 7 PEP CompactPCI Standard Backplane Fam 14 8 PEP CompactPCI Standard Backplanes Mechanical Characteristics 14 ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page v Preface CPCI Backplane r This page was intentionally left blank Page vi 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface List of Figures 1 PEP Modular Computers Slot Numbering both 3U and 6U boards 2222 3 2 Backplane Clock Assignment SU backplanes mrrrrrrrrnnnnnnnnnrrrrnrnnrrrrrrrnrnnerennn 5 3 Backplane Clock Assignment 6U backplanes rrrrrnnnnnnnrrrrrvnnnnnnnnrrrnnrnrrnnnnnnr 5 4 Orientation and Pinouts of AC DC Line Connectors rrrrrrrrrrrrrnrnnnnnrrrnnrrnrnnnnnnr 6 5 DIN M24 8 Power Supply Connector 7 6 ATX Power Supply Conector on 3U Backplane left and 6U Backplanes 10 7 Board Rack Coding Keys enn 12 H ID 24229 Rev 01 2002 PEP Modular Computers GmbH Page vii Preface CPCI Backplane r This page was intentionally left blank Page viii 2002 PEP Modular Computers GmbH ID 24229 Rev 01 CPCI Backplane Preface Proprietary Note This document c