Home

Edison Dehumidifier

image

Contents

1. Edison products or services do not imply that Edison intends to make them available outside the territories served by its sales companies or distributors O5L2144
2. the unit because it takes 10 minutes to reposition If the unit still does not start after 10 minutes please ask your local distributor service station to repair 7 When the dehumidifier is operating it s a normal situation that the working compressor may cause some heat and bring the ambient temperature up 8 When the product is defrosting the related indicating light will illuminate And during the defrosting the compressor will stop but the motor will keep working DRAINING INSTRUCTION Draining water can storage in the water tank or be continuous drained by PVC tube The PVC tube is not included in the product USAGE OF WATER TANK When dehumidifying the condensing water may be drained to water tank And the unit will stop working with indicating light illuminating when the water tank is full of water please pour out the water that time 1 Take out the water tank as Fig 01 and pour out the water 2 Put the water tank back 3 Then the unit will follow the setting humidity to work automatically CONTINUOUS DRAINAGE 1 Before continuous draining water please a f I take out the water tank and plug a I i U DOOM fl I Mli Aii l draining tube to draining hole See Fig W 02 Then put the water tank back iF f A a 2 Draining tube should place lower than s Le a the draining hole to let water flow out FILTER REMOVAL 1 Take out
3. Front housing might be damaged power cord and wire is broken the unit is dropped or break down 4 Please ask professional service agent to repair the product 4 Improper repair might cause damage to users 5 Disconnect the appliance from power supply before moving or cleaning the product and also when the product is not in used Humidity control switch 6 Please operate the product with specified electricity voltage Air Inlet Back housing 7 Please use this product only for household appliance and follow Drain hole the designed purpose l 5 AO Ue 8 Do not put any stuff on the product Water tank 9 In order to avoid water leakage please clean the water tank 6 before moving the product 10 Do not incline the product or leaking water may damage the 7 product 11 This appliance is not intended for use by persons including 8 children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been supervised or given instruction concerning use of the appliance by a person responsible for their safety Children Display panel should be supervised to ensure that they do not play with the Water tank full indicator Operation indicator 12 Please keep the product from the wall or other barriers in a Defrost indicator appliance minimum distance of 50 cm Dry forgoodi EdISON 13 Please install the appliance following the country wiring laws
4. IONS ED 16B Specification Power Supply 220 240V 50Hz Power Input 410W Rated Current Net Weight Moisture Removal 30 C RH80 Dimension W x D x H mm Applicable temperature Water Tank Capacity CE N 842 2006 R134a is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol Its total global warming potential GWP is 1300 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible hazards to the environment or human health from uncontrolled waste disposal please recycle it to prove the sustainable reuse of material lL resources Please ask return and collection systems or contact the retailer where the product was purchased to return your used device they can recycle products Edison Dry for good Naav Solutions Inc NSIl reserves the right to change specifications or other product information without notice This publication could include technical inaccuracies or typographical errors NSI PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdications do not allow disclaimer of express or implied warranties therefore this disclaimer may not aoplv to vou Copy right C E ne4z2006 Naav Solutions Inc 2012 All Rights Reserved R134a Kyoto Covered Reference in this publication to
5. USER S GUIDE 5 Thank you for selecting our products Please follow guideline in US R S MAN UAL this user s manual for maximizing dehumidification efficiency and longer lifetime PRODUCT REGISTRATION Record Model No and Serial No of this dehumidifier in space provided below for future service and maintenance Important Keep a copy of your bill of sales and warranty card for future service If service is performed it is in your best interest to obtain and keep all receipts CONTENT Safety Information Operating Instruction Display Panel Description Operating Instruction Warning Draining Instruction Usage of Water Tank Continous Drainage Filter Removal Maintenance Instruction Warrantee Policy Specifications m pungu Operate dehumidifier only as instructed in this user s manual Ed ISON Dehu Mm id ifier these instructions are not meant to cover every possible conditions and situations that may occur Common sense and general caution must be used when installing operating andmaintaining any Model ED 16B appliance SAFETY INFORMATION PRODUCT INTRODUCTION 1 Please read the manual carefully before the first time using this product and storage the unit in safe place to avoid electricity 1 Display panel 2 leakage flaming or person injure Air outlet 1 3 2 Do not put this product in the water or any other liquids Handel 3 Stop using this appliance in below situations or the product
6. ae TRN OPERATING INSTRUCTION STARTING THE UNIT 1 First please rotate the humidity switch in a leftward direction to the end which is the OFF position 2 Plug in the dehumidifier 3 Rotate the humidity switch in a leftward direction to turn on the unit The humidity will decrease every time you rotate the switch to left side and it will enter continuous humidifying mode when you rotate it to the end TURNING OFF THE UNIT 1 Please rotate the humidity switch in a rightward direction to the end and then the unit will be turned off 2 If the dehumidifier is not in use for a long time please disconnect the power cord plug from the outlet WARNING 1 When operating the dehumidifier please do not set the humidity higher than ambient humidity 2 When indicating light illuminates please pour the water out of the tank and put it back Then the product will resume working 3 When the product shut down please wait at least 3 minutes before restarting the unit to prevent damaging the compressor 4 The value on the calibration shows the relative humidity 5 The applicable operating temperature range for this unit is 5 32 C 6 lf the dehumidifier can t start the indicating light does not illuminate or the dehumidifier shut down unreasonably please make sure whether the plug is connected firmly to power supply If the plug and power supply are in normal condition please wait for 10 minutes before restart
7. the water tank before remove the filter 2 Pulling out the filter with handles of filter 3 Wash the filter with cool water cooler than 40 C every two weeks and put filter back after it air dried naturally MAINTENANCE INSTRUCTION 1 The unit is not allowed to be placed on surface which is soft or not flat to avoid the unit cause noise vibration and water or electricity leakage when operating 2 Never insert any slim rod or hard stuff into the unit to avoid the damage of the unit 3 Please disconnect the power cord to the power supply when you turn off the unit or intend to stop using for long time don t do 4 In order to improve the performance of dehumidifier please keep the unit in open place away from barriers which may block the air DO NOT BLOCK AIR GRILL 5 Please wash the filter with cool water cooler than 40 C but not gasoline or alcohol every two weeks and put filter back after it air dried naturally WARRANTY POLICY The warranty period is 12 months from the date of purchasing The warranty is limited to free replacement and shippingof any faulty part or manufacturing errors All claims mustbe supported by evidence that the failure has occurredwithin the warranty period and that the unit has been operatedwithin the designed parameters specified All warranty claims must specify the model serial number These details are printed on the unit identification plate SPECIFICAT