1. i m D x D a n Leica FlexLine plus Quick Guide Version 2 0 English F when it has to be right eca Geosystems FlexLine plus Important Information about your Instrument 1 AW S Laser products Important Information about your Instrument Read and follow the User Manual on the accompanying USB stick before using the product or the accessories delivered with the product Keep for future reference e Measuring horizontal and vertical angles e Measuring distances e Visualising the aiming direction and vertical axis The instruments contain the following laser products Laser product Laser class EDM Electronic Distance Measurement module e measurements with reflectors Class 1 e measurements without reflectors Class 3R EGL Electronic Guide Light Exempt Group Laser plummet Class 2 optional laser product FlexLine plus Important Information about your Instrument CAUTION CAUTION e The classification for the EDM and Laser plummet is in accordance with IEC 60825 1 2007 03 e The classification for the EGL is in accordance with IEC 62471 2006 07 From a Safety perspective class 3R laser products should be treated as potentially hazardous Precautions 1 Prevent direct eye exposure to the beam 2 Do not direct the beam at other people From a Safety perspective class 2 laser products are not inherently safe for the eyes Prec
2. Instrument compo nents part 2 of 2 My Yi 07 ET ys aN 001947_002 n O P q r S FlexLine plus Instrument Components Focusing telescope image Eyepiece focusing graticule Battery cover Serial interface RS232 Foot screw Display Keyboard model may vary depending on instrument Stylus FlexLine plus Instrument Components Keyboard Color amp Touch keyboard I LL I 1 x IJK MNO POR 1 n 1 I a7 stu vwx vz I B 1I ABC DEF GHI LL 1 TSOX_139 Standard keyboard TSOX_011 10 Alphanumeric keyboard Fixed keys Navigation key ENTER key ESC key Function keys F1 to F4 Alphanumeric keypad Stylus Keys Description Page key Displays the next screen when several screens are avail able FNC Favourites key Quick access to measurement supporting functions User key 1 User key 2 Programmable with a function from the Favourites menu Navigation key Controls the focus bar within the screen and the entry bar within a field ENTER key Confirms an entry and continues to the next field Turns off the instrument when held for 3 seconds ESC key Quits a screen or edit mode without saving changes Returns to next higher level Function keys F1 to F4 that are assigned the variable functions displayed at the bottom of the screen Alphanumeric keys for entry of text
3. and numerical values FlexLine plus Instrument Components 11 FlexLine plus Instrument Components 12 Container contents a bcd i j a Battery charger b Diagonal eyepiece c Data cable USB RS232 d Clip on bubble e Holder for height meter f Flat prism g Mini prism pole h Height meter i Protective cover Lens hood Cleaning cloth j Data cable USB mini USB k Mini prism I Adjustment tools m Batteries n Flat or mini prism adapter o Leica industrial grade USB memory stick p Battery q Tip for mini prism pole r Counterweight diagonal eyepiece s Instrument t Manuals Optional 3 Technical Data Environmental Temperature specifications Operating temperature C Storage temperature C 20 to 50 40 to 70 Protection against water dust and sand IP55 IEC 60529 Humidity Max 95 non condensing The effects of condensation are to be effectively counteracted by periodically drying out the instrument FlexLine plus Technical Data 13 FlexLine plus Care and Transport 14 4 Care and transport Care and Transport e Carry the product in its original container or carry the tripod with its legs splayed across your shoulder to protect the product against shock and vibration e Periodically carry out test measurements and perform the field adjustments indi cated in the User Manual particularly after the produ
4. SB or auto detect communication icon For C amp T Tapping the icon opens the Interface Settings screen Displays the status of the battery For C amp T Tapping the icon opens the Info screen Displays that offset is active H Horizontal angle is set to left side angle measurement FlexLine plus Operation 17 FlexLine plus Operation 18 Main Menu a b a Quick Survey program to begin meas uring immediately AE i b To select and start programs ca FlexField c To manage jobs data codelists formats and USB memory stick files d To export and import data e To change EDM configurations communication parameters and re general instrument settings Transfer Brees f To access instrument related tools such as check and adjust personal Startup settings PIN code settings ae licence keys system memory infor mation and firmware upload ae Despite an automatic defragmentation the memory gets fragmented after a while Please format the internal memory periodically to maintain the instrument perfor mance Q Survey program Quick Survey Zu After switching on and setting up correctly the instrument is immediately ready for measuring 50 0000 g 66 6667 g Meas Dist Store Meas To start measurements and save the measured values Dist To start measurements and display the measured values Store To save the displayed values L Code To find enter codes Available on page 4 4 or Code Or o
5. autions 1 Avoid staring into the beam 2 Avoid pointing the beam at other people FlexLine plus Important Information about your Instrument Locations of laser apertures 003248 002 LED beam red EGL LED beam yellow EGL Laser beam EDM Laser beam Laser plummet Exit for laser beam Laser plummet The product must not be disposed with household waste national regula ance with the essential requirements and other relevant provisions of tions applicable European Directives The declaration of conformity may be consulted at http www leica geosystems com ce Conformity to Hereby Leica Geosystems AG declares that the instrument is in compli Conformity to e FCC Part 15 applicable in US national regula e Hereby Leica Geosystems AG declares that the instrument with Communication tions side cover is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC and other applicable European Directives The declaration of conformity may be consulted at http www leica geosys tems com ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can C be placed on the market and be put into service without restrictions in any EEA Member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and operation FlexLin
6. ct has been dropped stored for long periods or transported The target line of the visible laser can drift during the product lifetime Inspect the target line visually on a regular base If necessary visit an authorised Leica Service Centre for adjustment 5 Operation S The battery must be charged before using it for the first time Turning on and off the instrument FlexLine plus Operation 15 FlexLine plus Operation Screen Meas Dist i S Title of screen Focus in screen Active field Status icons Fields Softkeys 50 0000 g 66 6667 o ses EPERE PETE Meas Dist Store e a Status icons b Title of screen c Focus in screen Active field d Fields e Softkeys gt Tapon an icon field or tab to run a function Icons Icon Description Le ce Displays the selected prism icon the EDM measurement A activity icon or the active laser pointer icon For C amp T Tapping FA the icon opens the EDM Settings screen Displays the telescope position face or face II or the compensator status on off or out of range For C amp T Tapping the icon opens the Level amp Plummet screen Displays the keypad mode numeric or alphanumeric The icon is displayed when an editable field is highlighted For C amp T Tapping the icon switches the keypad mode Displays the communication port icon RS232 Bluetooth or U
7. e plus Important Information about your Instrument 5 FlexLine plus Instrument Components 2 Instrument Components Instrument compo ab c d nents part 1 of 2 Ergofocus tele scope a b c d f g i Optical sight Detachable carrying handle with mounting screw Objective with integrated Electronic Distance Measurement EDM Exit for EDM laser beam Vertical drive On Off key Trigger key Horizontal drive Display Second keyboard identical to first keyboard Optional for TSO2 plus Instrument compo j k nents part 2 of 2 j Focusing telescope image k Eyepiece focusing graticule I Battery cover m Serial interface RS232 n Foot screw o Display p Keyboard 002725_002 FlexLine plus Instrument Components FlexLine plus Instrument Components Instrument compo nents part 1 of 2 Finefocus tele scope TSOX 009a a Compartment for USB memory stick and USB cable ports Bluetooth antenna Optical sight Detachable carrying handle with mounting screw Electronic Guide Light EGL Objective with integrated Electronic Distance Measurement EDM Exit for EDM laser beam Vertical drive On Off key Trigger key Horizontal drive Second keyboard identical to first keyboard Optional for TSO6 plus Optional for TS06 plus TSO9 plus 3
8. ight CET O ss C588 O cts ni Bae I oh a OF mm N ge aos SX Oo i o0 J lt n E s n gt n J UO G T mall N ei N Geosystems
9. n any page press the FNC Favourites key and select Coding Station To enter station data and set the station Set Hz To set the orientation to a user defined horizontal direction Hz 4 Hz To set the horizontal angle reading to the left anticlockwise or to the right clockwise FlexLine plus Operation 19 FlexLine plus Operation EDM Settings EDM mode 20 P Precise Fine measuring mode for highest precision measurements with prisms 1 5 mm 2 ppm P Precise amp Fast P Tracking Quick measuring mode with prisms with higher measuring speed and high accuracy 2 mm 2 ppm For continuous distance measurements with prisms 3 mm 2 ppm Tape For distance measurements using Retro reflective targets 3 mm 2 ppm P Long gt 4 0 km NP Precise For long range distance measurements with prisms 5 mm 2 ppm Available for instruments For distance measurements without prisms 2 mm 2 ppm gt 500 m 4 mm 2 ppm NP Tracking For continuous distance measurements without prisms 5 mm 3 ppm Prism type Round GPR Leica Const 0 0 mm Leica Const 17 5 mm Mini0 GMP111 0 Leica Const 0 0 mm Jp Mini SMP222 Leica Const 34 4 mm 360 GRZ4 Leica Const 23 1 mm 360 Mini GRZ101 Leica Const 30 0 mm Tape GZM Leica Const 34 4 mm Leica Const 34 4 mm User 1 For any prism modes the user can define two of their own Use
10. r 2 prisms Constants can be entered in mm in either Leica Const or Abs Const For example User prism constant 30 0 mm Leica Const 4 4 mm 34 4 30 4 4 Abs Const 30 0 mm FlexLine plus Operation 21 FlexLine plus Operation 22 Menu Tree FT Q Survey Programs Station Setup Survey Stakeout Tie Distance COGO Area amp DTM Volume Remote Height Traverse Reference Line Reference Arc Reference Plane Road 2D Road 3D Manage Job Fixpoints Meas Data Codes Formats Del Data USB Stick Transfer Export Import Settings I Work Regional Data Screen EDM Interface Tools Adjust Startup Info Licence PIN Load FW FlexLine plus Operation 23 Total Quality Management Our commitment to total customer satisfaction Re Leica Geosystems AG Heerbrugg Switzerland has been certified as being equipped with a quality system which 7 O IVI meets the International Standards of Quality Management and Quality Systems ISO standard 9001 and Environmental E iso 9001 1S0 14001 Management Systems ISO standard 14001 Ask your local Leica Geosystems dealer sales representative for more informa tion about our TQM program Leica Geosystems AG Heinrich Wild Strasse CH 9435 Heerbrugg Switzerland Phone 41 71 727 3131 www leica geosystems com when it has to be r