IntesisBox PA-RC-KNX

image

Contents

1. ueeeeeeeeeeeennen nn nn Immer 13 4 1 8 Enable object Error Text Code 14byte seeeeeeeeenmmm e 14 4 2 Mode Configuration dialog ccccccccccceee eee eee eee eee eee e eee e eee e nena eee eeeeeeeeeeeeeeenennnegs 14 4 2 1 Indoor Unit has HEAT MOGCxcccccascincecaiasadeserssetisartiasaieidesdsieteiarsiaraaaiiantes 14 4 2 2 When mode is AUTO Status objs report actual operating status 15 4 2 3 Enable use of Heat Cool bit type Obi sese eee 15 4 2 4 Enable PID Compat Scaling Mode Objects ccesesseeeeenmm mmm nnn 15 4 2 5 Enable use of object for Mode cece ccceccseeuseeueeeseeueeuteeuseuueeuteenseuueenns 16 4 2 6 Enable use of bit type Mode objects for control eeeeee eere 17 4 2 7 Enable use of bit type Mode objects for status eeeeeennnnnnnnne 17 4 2 8 Enable use of Text object for Mode sssesssesssseenn nennen nnn nnn 17 4 3 Special Modes Configuration dialog seeeeeeeeeeseeee nnns 18 4 3 1 Enable use of POWER mode sssseeeeeeeenn m enhn nnnm n nnn ann 19 4 3 2 Enable use or ECONOMY mode cu iive va dA Ya o CUN E c aii cae XOXU GRE Pea ar A 20 4 3 3 Enable use of ADDITIONAL HEATING mode eeeeeen menn 20 4 3 4 Enable use of ADDITIONAL COOLING mode eene HH 21 4 4 Fan Speed Configuration dialog orar o ee ac je a C c Xi C ci Cj C X 22 4 4 1 When fan
2. o If set to no the objects will not be shown o If set to yes the Status_ Fan Speed objects for Speed 1 Speed 2 and Speed 3 will appear When a Fan Speed is enabled a 1 value is returned through its bit type object 4 4 6 Enable use of Text object for Fan Speed This parameter shows hides the Status_ Fan Speed Text communication object E 68 Status Fan Speed Text DPT 16 001 14byte ASCII String o If set to no the object will not be shown o If set to yes the Status_ Fan Speed Text object will appear Also in the parameters will be shown five text fields one for each Fan Speed that will let modify the text string displayed by the Status_ Fan Speed Text when changing a fan speed gt String when fan speed is AUTO AUTO gt String when fan speed is 1 SPEED 1 gt String when fan speed is 2 SPEED 2 gt String when fan speed is 3 SPEED 3 Figure 4 14 Parameter detail 4 5 Vanes Up Down Configuration dialog Device 1 1 1 PA RC Interface General Indoor unit has U D Vanes Yes lt Mode Configuration see docum for your indoor unit Special Modes Configuration Fan Speed Configuration Available AUTOs in Indoor Unit 3 E see docum for your indoor unit l Vanes Up Down Configuration Temperature Configuration DPT object type for Vanes Up Down Enumerated DPT 5 010 x Scene Configuration annan Switch Off Timeouts Configuration Enable use of object for Vanes U D
3. e When a O value is sent to the Contro communication object Additional Heating Mode will be disabled and the Status object will return this value A Important This mode will ALWAYS turn on the indoor unit in Heat mode gt Action time for this mode minutes Duration of Additional Heating Mode in minutes once started gt Setpoint temp for this mode C Setpoint temperature that will be applied while in Additional Heating Mode gt Fan Speed for this mode Fan Speed that will be set in the unit while in Additional Heating Mode 4 3 4 Enable use of ADDITIONAL COOLING mode This parameter shows hides the Control Start Additional Cool Mode and Status_ Additional Cool Mode communication objects The Additional Heating Mode lets change the Setpoint Temperature and the Fan Speed within a given period of time S 38 Control Additional Cool DPT 1 010 1bit 0 Stop 1 Start a 86 Status_ Additional Cool DPT 1 001 1bit 0 Off1 On o If set to no the objects will not be shown o If set to yes the Control Start Additional Cool Mode and Status Additional Cool Mode objects and new parameters will appear e When a 1 value is sent to the Control communication object Additional Cooling Mode will be enabled and the Status object will return this value e When a O value is sent to the Control communication object Additional Cooling Mode will be disabled and the Status object will return this value A Important
4. IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 3 1 Enable use of POWER mode This parameter shows hides the Contro _ Power Mode and Status Power Mode communication objects The Power Mode lets change the Setpoint Temperature and the Fan Speed within a given period of time a 35 Control Power Mode DPT_1 010 1bit 0 Stop 1 Start a 83 Status Power Mode DPT 1 001 Lbit 0 Off1 On o If set to no the objects will not be shown o If set to yes the Control Power Mode and Status Power Mode objects and new parameters will appear Enable use of POWER mode yes lt dd Action time for this mode minutes 2 0 permanent unlimited gt Setpoint delta increase HEAT or 20 C decrease COOL in Celsius 4 Fanspeed for this mode SPEED 3 if avail S Figure 4 10 Parameter detail e When a 1 value is sent to the Contro communication object Power Mode will be enabled and the Status object will return this value e When a 0 value is sent to the Contro communication object Power Mode will be disabled and the Status J object will return this value A Important This mode will ONLY work if the indoor unit is both turned on and in a Heat Cool Auto Heat or Auto Cool Mode Action time for this mode minutes Duration of Power Mode in minutes once started Setpoint delta incre
5. 0 Decrease l Increase DPT 1 007 gt Does sequence include No AUTO vanes Up Down gt Rollover Vanes at upper lower limit Yes when controlling with obj mn Figure 4 17 Parameter detail gt DPT type for Vane Up Down obj This parameter lets choose between the datapoints O Up 1 Down DPT 1 008 and O Decrease 1 Increase DPT 1 007 for the Contro Vanes U D object Intesis Software S L All rights reserved URL http www intesis com 27 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Does sequence include AUTO vanes Up Down This parameter lets choose if AUTO function is included yes or not no in the sequence when using Control Vanes U D object as shown in the discontinuous segment at the picture below gt Roll over Vanes at upper lower limit This parameter lets choose if roll over will be enabled yes or disabled no for the Control Vanes U D object Only if Roll over is enabled elie ee ee ee ee NE n RIRACRR O tB Only if Roll over is enabled Up Increase Down Decrease If Available 4 5 5 Enable Vanes U D Man Auto objects for control and status This parameter shows hides Control Vanes U D Man
6. emos rw mme pue D jesemmimeme 0 emos rm mee ume fw ewucmm 00 0 49 Speed 1 50 82 Speed 2 11 Control Fan Speed 3 Speeds 1 byte DPT Scaling 5 001 WIT 83 100 Speed 3 Intesis Software S L All rights reserved URL http www intesis com 54 60 This information is subject to change without notice n tes i SS E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL software tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Control Fan Speed 3 Speeds 1 byte DPT Enumerated 5 010 WIT Control_ Fan Speed 1 bit DPT_Step 1 00 Control_ Fan Speed 1 bit DPT_UpDown 1 00 1002 1002 1002 EIN pu 1008 1 byte DPT_Scaling seo 1002 1002 1002 E a 1 Speed 1 2 Speed 2 3 Speed 3 0 Manual 1 Auto 1 Set Fan Speed 1 1 Set Fan Speed 2 1 Set Fan Speed 3 0 Decrease 1 Increase Gaia MANES UPD POS Pos3 88 100 Pos4 Control_ Vanes U D 4 pos 1 byte 1 Posi 2 Pos2 3 Pos3 DPT Enumerated 0 Manual 1 Auto 0 Manual 1 Auto2 0 Manual 1 Auto3 1 Set Position 1 i 0960 3796 Pos1 38 62 Pos2 6396 879 1 Set Position 2 Control Vanes U D Pos3 1 Set Position 3 1 bit DPT Bool Control Vanes U D Pos4 1 bit DPT Bool 1 002 wil 1 Set Position 4 Control Vanes U D 1 bit DPT_Step 1 007 ETE 0 Decrease 1 Increase Intesis Sof
7. o value and viceversa o Forthe long operation the binary input will send an increase step after a decrease step and viceversa A Important Note that the first long operation in toggle depends on the last short operation meaning that after a 1 value will be sent a decrease step and after a O0 value will be sent an increase step A Important The time period between a short and a long operation is defined in the parameter Short long operation limit x100ms Increasing step This parameter lets select the increasing step value in that will be sent for a long operation gt Decreasing step This parameter lets select the decreasing step value in that will be sent for a long operation gt Short long operation limit x100ms This parameter lets introduce the time period difference for the short and the long operation gt Cycl send period in long oper x100ms This parameter lets configure a time in seconds for the cyclical sending of a long operation o When Shutter Blind is selected the communication objects and new parameters for the Input x will appear as shown below Intesis Software S L All rights reserved URL http www intesis com 45 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC
8. 60 u This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng o When Enumerated DPT 5 010 is selected Contro Fan Speed and Status Fan Speed communication objects for this DPT will appear 82 11 Control Fan Speed 3 Speeds DPT 5 010 1byte Speed values 1 2 3 82 63 Status Fan Speed 3 Speeds DPT 5 010 1byte Speed Values 1 2 3 The first fan speed will be selected if a 1 is sent to the Contro _ object The second one will be selected sending a 2 the third one will be selected sending a 3 The Status_ object will always return the value for the fan speed selected A Important If a O value is sent to the Control object the minimum fan speed will be selected If a value bigger than 3 is sent to the Control object then the maximum fan speed will be selected o When Scaling DPT 5 001 is selected Contro Fan Speed and Status Fan Speed communication objects for this DPT will appear B 11 Control Fan Speed 3 Speeds DPT 5 001 1byte Thresholds 50 and 63 a 63 Status Fan Speed 3 Speeds DPT 5 001 1byte 3325 67 and 100 The next table shows the range of values that can be sent through the Contro object and the value returned by the Status object Fan Speed 1 Fan Speed 2 Fan
9. FS FSM User s manual r0 eng SH 93 Status_In3 Shut Blind Step DPT_1 023 1bit 0 Step Up 1 Step Down CE 94 Status In3 Shut Blind Move DPT 1 023 1bit 0 Move Up 1 Move Down Function Shutter B lind gt Send telegram after No action bus recovery gt Operation Toggle Up Down gt Method Step Move Step gt Short long operation limit 10 xLOOms LS gt Vanes adjustment time 10 x100ms a Figure 4 43 Parameter detail gt Send telegram after bus recovery This parameter lets select if the Binary Input x will send a telegram or not after a bus recovery and the type of telegram sent if enabled e When No action is selected no telegram will be sent after a bus recovery e When Move Up is selected the binary input will send a telegram with a o value after a bus recovery Also a new parameter will appear see below e When Move Down is selected the binary input will send a telegram with a 1 value after a bus recovery Also a new parameter will appear see below dd gt Sending delay after 10 bus recovery seconds Figure 4 44 Parameter detail Sending delay after a bus recovery seconds This parameter lets configure a delay in seconds that will be applied after a bus recovery and after which a telegram will be sent Operation This parameter lets select the value that the Binary Input x will send on a rising ed
10. No L Binary Input 1 Configuration Enable Vanes U D Man Auto objects No i m fi Binary Input 2 Configuration for Control and Status Binary Input 3 Configuration Binary Input 4 Configuration Enable use of bit type Vanes U D objects No for Control oe Enable use of bit type Vanes U D objects No for Status rr ULL c amp G C CCOCLLLAEMMMPPMPPDAAw e qm 0 UA Enable use of Text object for Vanes U D No x Figure 4 15 Vanes Up Down Configuration dialog All the parameters in this section are related with the Vanes Up Down properties and communication objects Intesis Software S L All rights reserved URL http www intesis com 25 60 u This information is subject to change without notice n te Sx i amp E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 5 1 Indoor unit has U D Vanes This parameter lets choose if the unit has Up Down Vanes available or not Indoor unit has U D Vanes Yes see docum for your indoor unit rp oe Figure 4 16 Parameter detail o If set to no all the parameters and communication objects for the Up Down Vanes will not be shown o If set to yes all the parameters and communication objects if enabled in the parameters dialog for the Up Down Vanes will be shown A Important Read the documentation of your indoor unit
11. Scene x Value for Mode This parameter lets choose the mode of the indoor unit when the scene is executed The following options are available AUTO HEAT if available COOL FAN DRY or unchanged NVI gt Scene x Value for Fan Speed This parameter lets choose the fan speed of the indoor unit when the scene is executed The following options are available FAN SPEED 1 FAN SPEED 2 FAN SPEED 3 or unchanged NVI gt Scene x Value for Vane U D if available This parameter lets choose the vane position of the indoor unit when the scene is executed The following options are available VANES U D POS 1 VANES U D POS 2 VANES U D POS 3 VANES U D POS 4 VANES U D SWING or unchanged gt Scene x Value for Setp Temp C This parameter lets choose the setpoint temperature of the indoor unit when the scene is executed The following options are available from 16 C to 31 C both included or unchanged gt Scene x Value for Remote Lock This parameter lets choose the remote controller status of the indoor unit when the scene is executed The following options are available locked unlocked or unchanged A Important If any preset value is configured as unchanged the execution of this scene will not change current status of this feature in the AC unit A Impo
12. electronic control PA RC KNX 1i Bus A B connection Two wire cable Max 200 m PA RC KNX 1i with Panasonic RC Binary inputs for potential free Remote Controller contacts IntesisBox KNX TP 1 EIB bus AC Indoor Unit KNX I IN2 1 AC Unit A I I MEM M L LL LLL LLL B I L I Internal I I j electronic I l control Bus A B connection I Two wire cable a SIL i B i I an m mm e e e e mm m mm mm m l I 4 rs rp E De ee ag hag ne ek et Ee tet I Max 200 m Figure 2 2 PA RC KNX 1i connection diagrams Intesis Software S L All rights reserved URL http www intesis com 8 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 3 Configuration and setup This is a fully compatible KNX device which must be configured and setup using standard KNX tool ETS ETS database for this device can be downloaded from http www intesis com down eib PA RC KNX 1i zip Please consult the README txt file located inside the downloaded zip file to find instructions on how to install the database A Important Do not forget to select the correct settings of AC indoor unit being connected to the PA RC KNX 1i This is in Parameters of the device in ETS Intesis Software S L All rights
13. 100 Speed 3 1 00 67 Status_ Fan Speed 3 1 bit DPT_Bool Status_ Fan Speed Text 14 byte DPT String 8859 1 1 00 16 001 1 byte DPT Scaling 5 001 1 byte Status Vanes U D 4 pos 25 Posi 50 Pos2 75 Pos3 100 Pos4 Status Vanes U D 4 pos DPT Enumerated 1 Posi 2 Pos2 3 Pos3 4 Pos4 Intesis Software S L All rights reserved This information is subject to change without notice t URL http www intesis com IntesisBox is a registered trademark of Intesis Software SL n es IS E 1 002 0 Manual 1 Auto T 0 Manual 1 Auto2 W 0 Manual 1 Auto3 EU 1 Position 1 58 60 Email info intesis com tel 34 938047134 software IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Status Vanes U D Pos2 1 bit DPT Bool 1 002 R 1 Position 2 Status Vanes U D Pos3 1 bit DPT Bool 1 002 XN 1 Position 3 om Status Vanes U D Text 14 byte DPT String 8859 1 16 001 ASCII String Status Filter Status 1 bit DPT Bool r fo No Alarm 1 Alarm Status_ Error Alarm 1 bit DTP_Alarm 1 005 2 a No Alarm 1 Alarm Status_ Error Code 2 byte Enumerated R T No Error Any other see user s manual NM Status Error Text code 14 byte DPT String 8859 1 16 001 R r 0 Off 1 On 3 char MH Error Empty none Suns forro Kem xr o 8 Status Econo Mode 1 bit DPT Switch 1 001 Status Additional Heat 1 bit DPT Switch 001 Statu
14. 60 B This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 5 6 Enable use of bit type Vane U D objects for Control This parameter shows hides the bit type Control Vanes U D objects B 21 Control Vanes U D Pos 1 DPT 1 002 1bit 1 Set Position 1 B 22 Control Vanes U D Pos 2 DPT 1 002 1bit 1 Set Position 2 LE 23 Control Vanes U D Pos 3 DPT 1 00 1bit 1 Set Position 3 B 24 Control Vanes U D Pos 4 DPT_1 002 1bit 1 Set Position 4 o If set to no the objects will not be shown o If set to yes the Control Vanes U D objects for each Position will appear To activate a Vanes Position by using these objects a 1 value has to be sent 4 5 7 Enable use of bit tyoe Vane U D objects for Status This parameter shows hides the bit type Status Vanes U D objects B 735tatus Vanes U D Pos 1 DFT_1 002 1bit 1 Vanes in Position 1 gl 74 Status Vanes U D Pos 2 DPT 1 00 1bit 1 Vanes in Position Z B 75 Status Vanes U D Pos 3 DPT 1 002 1bit 1 Vanes in Position 3 B 76 Status Vanes U D Pos 4 DPT 1 002 Lbit 1 Vanes in Position 4 o If set to no the objects will not be shown o If set to yes the Status Vanes U D objects for each Position will appear When a Vanes Position is enabled a 1 v
15. If set to yes the Control Ambient Temperature object will appear Meant to be enabled when you want the temperature provided by a KNX sensor to be the reference ambient temperature for the air conditioner Then the following formula applies for calculation of real Control Setpoint Temperature sent to the AC unit AC Setp Temp KNX Setp Temp KNX Amb Temp KNX Setp Temp 2 AC Setp Temp AC indoor unit setpoint temperature KNX Amb Temp Ambient temperature provided from KNX KNX Setp Temp Setpoint temperature provided from KNX As an example consider the following situation User wants 19 C KNX Setp Temp User sensor a KNX sensor reads 21 C KNX Amb Temp In this example the final setpoint temperature that DK AC KNX 1i will send out to the indoor unit shown in AC Setp Temp will become 19 C 21 C 199C 2 189 C This is the setpoint that will actually be requested to Daikin unit This formula will be applied as soon as the Control_ Setpoint Temperature and Control Ambient Temperature objects are written at least once from the KNX installation After that they are kept always consistent Note that this formula will always drive the AC indoor unit demand in the right direction regardless of the operation mode Heat Cool or Auto 4 7 Scene Configuration dialog Device 1 1 1 PA RC Interface General Enabl f Yes
16. Off is selected the binary input will send a 1 value after a 0 value and viceversa e When No action is selected the binary input will not perform any action gt Value on falling edge This parameter lets select the value that the Binary Input x will send on a falling edge contact deactivated e When On is selected the binary input will always send telegrams with a 1 value e When Off is selected the binary input will always send telegrams with a o value e When Toggle On Off is selected the binary input will send a 1 value after a 0 value and viceversa e When No action is selected the binary input will not perform any action gt Cyclical sending This parameter lets enable disable cyclical sending when a determined condition is met e When When output value is On is selected everytime a 1 value is sent it will be sent cyclically Also a new parameter will appear see below e When When output value is Off is selected everytime a O value is sent it will be sent cyclically Also a new parameter will appear see below e When Always is selected the binary input will send any value cyclically Also a new parameter will appear see below e When Never is selected cyclical sending will be disabled gt Period for cyclical sending seconds This parameter lets configure a time in seconds for the cyclical sending Intesis
17. Speed 3 Control 0 49 50 82 83 100 A Important Read the documentation of your indoor unit to check how many fan speeds are available 4 4 3 Enable use of object for Fan Speed This parameter shows hides the Control Fan Speed communication object which lets increase decrease the indoor unit fan speed by using two different datapoint types a 16 Control Fan Speed DPT_1 007 1bit 0 Decrease 1 Increase o If set to no the object will not be shown o If set to yes the Control Fan Speed object and a new parameter will appear Intesis Software S L All rights reserved URL http www intesis com 23 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Enable use of object for Fan Speed Yes gt DPT type for Fan Speed object Decrease 1 Increase DPT 1 007 C gt Rollover Speed at upper lower limit Yes when controlling with obj Figure 4 13 Parameter detail gt DPT type for Fan Speed Object This parameter lets choose between the datapoints O Up 1 Down DPT 1 008 and O Decrease 1 Increase DPT 1 007 for the Contro Fan Speed object gt Roll over Speed at upper lower limit This parameter lets choose if roll over will be
18. This mode will ALWAYS turn on the indoor unit in Cool mode Action time for this mode minutes Duration of Additional Cooling Mode in minutes once started Setpoint temp for this mode 9C Setpoint temperature that will be applied while in Additional Cooling Mode Intesis Software S L All rights reserved u URL http www intesis com 21 60 This information is subject to change without notice n te Sx i em E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Fan Speed for this mode Fan Speed that will be set in the unit while in Additional Cooling Mode 44 Fan Speed Configuration dialog Device 1 1 1 PA RC Interface General When fan is AUTO Status objs report No x a actual operating status speed1 2 Special Modes Configuration Fan Speed Configuration DPT object type for fanspeed Enumerated DPT_5 010 Vanes Up Down Configuration Enable use of object for Fan Speed No Temperature Configuration REN Enable Fan Speed Man Auto objects No Switch Off Timeouts Configuration for Control and Status Binary Input 1 Configuration Binary Input 2 Configuration Enable use of bit type Fan Speed objects No v for Control a Binary Input 3 Configuration Binary Input 4 Configuration Enable use of bit type Fan Speed objects No x fo
19. be performed A Important The T1 time have to be defined in the Short long operation limit x100ms parameter Also the T2 time have to be defined in the Vanes adjustment time x100ms parameter Short long operation limit x100ms This parameter lets introduce the time period difference for the short and the long operation T1 time gt Vanes adjustment time x100ms This parameter lets introduce the time period for the vanes adjustment blind movement T2 time o When Value is selected the communication objects and new parameters for the Input x will appear as shown below Fd 95Status lnd Value DPT 5 010 1byte 1 byte unsigned value gt Function Value 4 gt Send telegram after Fixed value bus recovery l gt Sending delay after 10 bus recovery seconds gt DPT to be sent DPT 5 010 Lbyte gt Value on raising edge 234 when contact activated Figure 4 45 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 47 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Send telegram after bus recovery This parameter lets select if the Binary Input x will send a telegram or not after a bus recovery and the type o
20. com IntesisBox is a registered trademark of Intesis Software SL software tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Control Store Scene3 1 bit DPT Bool 1 002 1 Store Scene O s eremum Dim omm 1 H emet am tee omes some emese 0000 s eermesesee im omms rooe wli ieee 0 e eo seats see omms sor TIRI saenl some TIRI 00 m eo ccatesanet tee omms sor wfe ieee 00 saenl TIRI SH HTHH wlr Joemer om 0 mner Tae um IR S i orreen H DH ons onsets io omes H IH vere er T E ates oii bere soe oree rons fw r pemmmrmere 0 wem s sma owor re mem que mfr jemam 0000 sae ies orca 2030s a r avast 3c 9 eec e s sone me vom al ef eae 00000 Intesis Software S L All rights reserved URL http www intesis com 57 60 This information is subject to change without notice n tes i S E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL software tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 58 Status Mode Heat 1 bit DPT_Bool 1 002 16 001 Status_ Fan Speed 3 Speeds 1 byte DPT_Scaling 5 00 Status_ Fan Speed 3 Speeds 1 byte DPT_Enumerated 5 01 R Status_ Fan Speed Manual Auto 1 bit DPT_Bool R Status_ Fan Speed 1 1 bit DPT_Bool 1 00 R Status_ Fan Speed 2 1 bit DPT_Bool 1 00 R 33 Speed 1 67 Speed 2
21. com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng The Status_ object will always return the value for the vane position selected A Important If a O value is sent to the Control object the Position 1 will be selected If a value bigger than 4 is sent to the Control_ object then the higher Position will be selected o When Scaling DPT 5 001 is selected Contro Vane Up Down and Status Vane Up Down communication objects for this DPT will appear LE 17 Control Vanes U D 4 Pos DPT 5 001 1byte Thresholds 36 63 and 88 LE 69 Status Vanes U D 4 Pos DPT 5 001 1byte 25 50 75 and 100 The next table shows the range of values that can be sent through the Contro object and the value returned by the Status object 0 37 38 62 63 87 88 100 4 5 4 Enable use of object for Vanes U D Control_ Status _ This parameter shows hides the Control_ Vane Up Down communication object which lets change the indoor unit vane position by using two different datapoint types B 25 Control Vanes U D DPT 1 007 1bit 0 Decrease 1 Increase o If set to no the object will not be shown o If set to yes the Control Vanes U D object and a new parameter will appear Enable use of object for Vanes U D Yes gt DPT type for Vanes U D object
22. for the Control Setpoint Temperature object will be the default 160C for the lower limit and 31 C for the upper limit o If set to yes it is possible to define temperature limits for the Control Setpoint Temperature object gt Control Set Temp Lower limit 9C This parameter lets to define the lower limit for the setpoint temperature gt Control Set Temp Upper limit 9C This parameter lets to define the upper limit for the setpoint temperature A Important If a setpoint temperature above the upper defined limit or below the lower defined limit is sent through the Control_ Setpoint Temperature object it will be ALWAYS applied the limit defined A Important When limits are enabled any setpoint temperature sent to the AC even through scenes special modes etc will be limited 4 6 4 Ambient temp ref is provided from KNX This parameter shows hides the Contro Ambient Temperature communication object which lets use an ambient temperature reference provided by a KNX device Intesis Software S L All rights reserved u URL http www intesis com 31 60 This information is subject to change without notice n te Sx i em E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng a 28 Control Ambient Temperature DPT 5 001 2byte C o If set to no the object will not be shown o
23. info intesis com i a software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134
24. is AUTO Status objs report actual operating status speed1 2 22 4 4 2 DPT object type for fanspeed eeeeeeeeeee nnnm mr 22 4 4 3 Enable use of object for Fan Speed cene nnm nnn 23 4 4 4 Enable use of bit type Fan Speed objects for Control 24 4 4 5 Enable use of bit type Fan Speed objects for Status eese 24 4 4 6 Enable use of Text object for Fan Speed eeeeeeennmmm mmn 25 4 5 Vanes Up Down Configuration dialog csssssseeeeeeen nennen 25 4 5 1 Indoor unit has U D Vanes ecsassaupuravt dE FUP ENDE EPICURUS PR Rd FUP 26 4 5 2 Available AUTOS i Indoor TTT 26 4 5 3 DPT object type for Vanes Up Down cs ss sss es e es e s e ce e e eee eee 26 4 5 4 Enable use of object for Vanes U D ccccccsceeeeeeeeeeeeeeeeeeeeeeeeeegeeeenennegs 27 4 5 5 Enable Vanes U D Man Auto objects for control and status 28 4 5 6 Enable use of bit type Vane U D objects for Control esee 29 4 5 7 Enable use of bit type Vane U D objects for Status eeeeeeeee 29 4 5 8 Enable use of Text object for Vane U D sssseeeeeenn mmn nne 29 4 6 Temperature Configuration dialog ssseeeeeeeeeee e nnn nnns 30 4 6 1 Periodic sending of Status AC Set eee 30 4 6 2 Enable use of object for Setpoint Temp ss ee x e e x e e x e K x e K K e K Ke 30 4 6 3 En
25. obj for Setpoint Temp No Vanes Up Down Configuration Temperature Configuration Enable limits on Control Setpoint obj INO et Scene Configuration Ambient temp ref is provided from KNX No x Switch Off Timeouts Configuration carefully read User Guide if enabled Binary Input 1 Configuration Binary Input 2 Configuration Binary Input 3 Configuration Binary Input 4 Configuration Figure 4 20 Default Temperature Configuration dialog All the parameters in this section are related with the Temperature properties and communication objects 4 6 1 Periodic sending of Status AC Setp This parameter lets change the interval of time in seconds from O to 255 at the end of which the AC setpoint temperature is sent to the KNX bus For a O value the AC setpoint temperature will ONLY be sent on change The AC setpoint temperature is sent through the communication object Status AC Setpoint Temp B 78 Status AC Setpoint Temp DPT_9 001 2byte C 40 Periodic sending of Status AC Setp 295 in seconds 0 No periodic sending Figure 4 21 Parameter detail A Important In case the ambient temperature is provided from KNX the setpoint temperature returned from this object will be the one resulting from the formula shown in the section 4 6 4 Ambient temp ref is provided from KNX 4 6 2 Enable use of object for Setpoint Temp This parameter shows hides the Control Setpoint Temp communicat
26. reserved URL http www intesis com 9 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 ETS Parameters When imported to the ETS software for the first time the gateway shows the following default parameter configuration Device 1 1 1 PA RC Interface General i l T Download latest database entry for this http www intesis com ues RS is product and its User Manual fram Special Modes Configuration 220 SSS Fan Speed Configuration send READs for Control objects on bus Yes M TE Ue T recovery T amp U flags must be active Temperature Configuration gt Delay before sending READs sec 10 Ga Scene Configuration Switch Off Timeouts Configuratior Scene to load on bus recovery startup none Binary Input 1 Configuration needs to define vals for that scene Buches aaa Disallow control from remote controller No Binary Input 3 Configuration HERR Binary Input 4 Configuration gt Enable comm obj Ctrl Remote Lock No Enable func Control Lock Control Obj No Enable func Operating Hours Counter No Enable use of objects for Filter No for Contral and Status Enable object Error Code 2byte No Enable object Error Text Code 14byte No 3 ASCII char Error Code Figu
27. the scene parameters and communication objects will be shown To execute a scene through the byte type object a value from O to 4 has to be sent correponding each one to a different scene i e 0 Scene 1 4 Scene 5 4 7 2 Scenes can be stored from KNX bus This parameter shows hides the Control Save Exec Scene and all the Control Store Scene if enabled communication objects B 39 Control Save Exec Scene DPT 18 001 Lbyte 0 4 Execl 5 128 152 Savel 5 2 45 Control Store Scene 1 DPT 1 002 1bit 1 Store Scene 1 B 46 Control Store Scene 2 DPT 1 002 1brt 1 Store Scene 2 a 47 Control Store Scene 3 DPT 1 002 1bit 1 Store Scene 3 B 48 Control Store Scene 4 DPT_1 002 1brt 1 Store Scene 4 27 49 Control Store Scene 5 DPT 1 002 1brt 1 Store Scene 5 o If set to no the communication objects will not be shown o If set to yes the communication objects and a new parameter will appear To store a scene through the byte type object a value from 128 to 132 has to be sent to the object correponding each one to a different scene i e 128 Scene 1 132 Scene 5 Scenes can be stored from KMX bus yes gt Enable use of bit objects yes lt for storing scenes from bus zc Figure 4 26 Parameter detail Enable use of bit objects for storing scenes from bus If set to no the objects will not be shown If set to yes the Control St
28. timeout to switch off the indoor unit 27 30 Control Switch Off Timeout DPT 1 010 1bit 0 Stop 1 Start 2 30 Control Window Contact Status DPT 1 009 Lbit Q Open l Closed o If set to no the object will not be shown o If set to yes the Control Switch Off Timeout object and new parameters will appear If a 1 value is sent to this object and the indoor unit is already turned on the switch off timeout will begin If a O value is sent to this object the switch off timeout will stop Enable use of Open Window Switch off yes timeout function j gt AC switch off timeout min ho g gt DPT for Window Switch off timeout Open 1 Closed Window DPT 1 009 gt Reload last On Off val once window no is closed p gt Disallow On Off operation while yes window is Open Figure 4 31 Parameter detail AC switch off timeout min This parameter lets select how much time in minutes to wait before switching off the indoor unit Intesis Software S L All rights reserved URL http www intesis com 36 60 u This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt DPT for Window Switch off timeout This parameter lets choose between the datapoints O Open 1 Closed Win
29. x Mode Configuration aoea ars Special Modes Configuration Scenes can be stored from KNX bus No Fan Speed Configuration Vanes Up Down Configuration Enable use of bit objects No x Temperature Configuration for scene execution Scene Configuration Scene 1 preset No Switch Off Timeouts Configuration Binary Input 1 Configuration Scene 2 preset No Binary Input 2 Configuration Binary Input 3 Configuration Scene 3 preset No M Binary Input 4 Configuration Scene 4 preset No Scene 5 preset No Figure 4 24 Parameter detail All the parameters in this section are related with the Scene properties and communication objects A scene contains values of On Off Mode Fan speed Vane position Setpoint Temperature and Remote Controller Disablement Intesis Software S L All rights reserved URL http www intesis com 32 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 7 1 Enable use of scenes This parameter shows hides the scene configuration parameters and communication objects LEN 39 Control Execute Scene DPT 18 001 l1byte 0 4 Execute Scene 1 5 Enable use of scenes yes Figure 4 25 Parameter detail o If set to no the scene parameters and communication objects will not be shown o If set to yes
30. Auto y Status Vanes U D Man Auto communication objects These objects can be different depending on the number of Auto s available in the indoor unit a 18 Control Vanes U D Man Auto DPT 1 002 Lbit 0 Manual 1 Auto B 19 Control Vanes U D Man Auto DPT 1 002 1bit 0 Manual 1 Auto2 B 20 Control Vanes U D Man Auto3 DPT 1 002 1bit 0 Manual 1 Auto3 B 70 Status Vanes U D Man Auto DPT 1 002 1bit 0 Manual 1 Auto B 71 Status_ Vanes U D Man Auto2 DPT 1 002 1bit 0 Manual 1 Auto 2 B 72 Status Vanes U D Man Auto3 DPT 1 002 1brt 0 Manual 1 Auto3 o If set to no the object will not be shown o If set to yes the Control_ Lamas U D Man Auto 2 3 y Status_ Lamas U D Man Auto 2 3 objects will appear e When a 1 value is sent to the Control_ communication object Vanes Up Down will be in Auto mode and the Status_ object will return this value e When a 0 value is sent to the Control_ communication object Vanes Up Down will be in Manual mode and the Status_ object will return this value A Important When activating Auto Mode in the indoor unit this one will choose the best position available for the Vanes Up Down This position will not be shown either in the KNX bus or in the remote controller A Important Read the documentation of your indoor unit to check how many AUTO modes are available Intesis Software S L All rights reserved URL http www intesis com 28
31. Communication object and parameter detail gt Enable comm obj Ctrl Remote Lock If set to no the object will not be shown If set to yes the Control Lock Remote Control object will appear e When a 1 value is sent to this communication object the remote controller is locked To be unlocked a O value must be sent The gateway remembers the last value received even if a KNX bus reset failure happens A Important If an initial scene is enabled and it has as Value for Remote Lock unchanged or unlocked this would unlock the remote controller because the initial scene has priority over the Control Lock Remote Control communication object 4 1 4 Enable func Control Lock Control Obj This parameter shows hide the Control Lock Control Obj communication object which depending on the sent value locks or unlocks ALL the Contro communication objects except itself B 34 Control Lock Control Objects DPT_1 002 Ibit 0 Unlocked 1 Locked o If set to no the object will not be shown o If set to yes the Control Lock Control Objects object will appear e When a 1 value is sent to this communication object all the Control objects will be locked To unlock a O value must be sent as the gateway remembers the last value received even if a KNX bus reset failure happens 4 1 5 Enable func Operating Hours Counter This parameter shows hides the Status Operation Hour Counter communication object which
32. IntesisBox PA HC KNX 11 o User s Manual Issue Date 03 04 2012 rO eng software IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Intesis Software S L All Rights Reserved Information in this document is subject to change without notice The software described in this document is furnished under a license agreement or nondisclosure agreement The software may be used only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Intesis Software S L Intesis Software S L Mila Fontanals 1 bis 1 08700 Igualada opain TRADEMARKS All trademarks and trade names used in this document are acknowledged to be the copyright of their respective holders Intesis Software S L All rights reserved URL http www intesis com 2 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Gateway for integration of Panasonic air conditioners into KNX TP 1 EIB control systems Compatible with FS and FSM Series air conditioners commercialized by Pan
33. L HEATING mode No v Temperature Configuration Scene Configuration Enable use of ADDITIONAL COOLING mode No Switch Off Timeouts Configuration Binary Input 1 Configuration Binary Input 2 Configuration Binary Input 3 Configuration Binary Input 4 Configuration Figure 4 9 Default Special Modes Configuration dialog The Special Modes can be parameterized through the ETS parameters dialog and they can be used to give extra functionality A Important When executing any of the Special Modes the real state of the indoor unit will NOT be shown in KNX A Important When the predefined time for the Special Mode is finished or a O value is sent to stop it the previous state will be recovered A Important If a value concerning On Off Mode Fan Speed or Setpoint Temperature is received from KNX while any Special Mode is running 1 the Special Mode will stop and the previous state will be recovered The value received will be also applied then A Important If a value concerning On Off Mode Fan Speed or Setpoint Temperature is modified through the remote controller the Special Mode will stop WITHOUT recovering the previous state Then the real indoor unit state will be shown in KNX including the new value received through the remote controller Intesis Software S L All rights reserved URL http www intesis com 18 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel
34. Software S L All rights reserved URL http www intesis com 43 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Period for cyclical sending 2 seconds Figure 4 40 Parameter detail o When Dimming is selected the communication objects and new parameters for the Input x will appear as shown below 821 91 5tatus In2 Dimming On Off DPT 1 001 1bit 0 Of 1 On B 92 Status In2 Dimming Steps DFT_3 007 Abit Dimming step gt Function Dimming gt Send telegram after No action bus recovery gt Mode for short long operation Toggle On Off Increase decrease gt Increasing step 100 lt Decreasing step 100 Short long operation limit 10 x100ms i gt Cyclical sending period x100ms o ra x 0 No cyclical sending Figure 4 41 Parameter detail gt Send telegram after bus recovery This parameter lets select if the Binary Input x will send a telegram or not after a bus recovery and the type of telegram sent if enabled e When No action is selected no telegram will be sent after a bus recovery e When On is selected the binary input will send a telegram with a 1 value after a bus recovery Also a new param
35. a decrease HEAT or increase COOL 9C This parameter lets configure the delta temperature increase or decrease that will be applied when the timeout has elapsed A Important When there is occupancy again after the application of a delta the same delta will be applied inversely i e In a room with AC in cool mode and 25 C setpoint temperature a 2 C delta is applied after the occupancy timeout setting the setpoint at 27 C because there is no occupancy in the room If the setpoint is raised to 299C during that period when the room is occupied again a 20C delta will be applied and the final setpoint temperature will then be 279C Enable secondary timeout If set to no nothing will be applied If set to yes a new timeout will be enabled and two new parameters will appear gt Timeout to apply action 2 icu E gt Action after timeout Apply Preset Delta i elapsed ESSE 2 gt Temp delta dec HEAT 20 C M or inc COOL 9C Figure 4 34 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 38 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Timeout to apply action minutes This parameter lets choose how much time to wait in minutes before executing t
36. aETaTEXQURU PRO DUNETPESTVETPPCQPEL UIT PT OPE 41 4 9 4 Disabling Ble ON RENI TE RTT TUUM 41 4 9 5 PUNCO ON m rr 42 B DO CCl CACO S acca ERTTETOTEL EI T TTE E E TEE TTD 50 6 AC Unit Types compatiDIlItV issuasdauuidubdarpiiasidauwERWbNd Kad q dU d Ed Aur R tea e Iby d iPad 51 fi PrO CO a I T UU UT TU 52 Appendix A Communication Objects Table ssseeeeeessee nennen nnne nnne nnns 54 Intesis Software S L All rights reserved URL http www intesis com 5 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 1 Presentation PA RC KNX 1i allows a complete and natural integration of PANASONIC air conditioners with KNX control systems Compatible with FS and FSM Series air conditioners commercialized by Panasonic Main features e Reduced dimensions quick installation e Multiple objects for control and status bit byte characters with KNX standard datapoint types e Status objects for every control available e Timeout for Open Window and Occupancy Sleep function also available e Control of the AC unit based in the ambient temperature read by the own AC unit or in the ambient temperature read by any KNX thermostat e AC unit can be controlled s
37. able limits on Control Setpoint obj cc e e e cece eee 31 4 6 4 Ambient temp ref is provided from KNX sss eee ee 31 A7 Sehe 6 een eUI c lt 15 er a eT Sehr ttt tt a 32 4 7 1 PENADIS SCO SOONG S vrcacmecurimonncestosniasatnaiasiieneasertecninestaumacanesssneriuaiaentas 33 4 7 2 Scenes can be stored from KNX DUS cs eee 33 Intesis Software S L All rights reserved URL http www intesis com 4 60 This information is subject to change without notice n te Sx em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 7 3 Enable use of bit objects for scene execution cceeeeeeeeeeeeeeeeeeeeeeeueeuaaeas 34 4 7 4 Scene X e n seasrcatarioreorecsdecateratns PUXTOKUUMARI EON TANANA KAASAN AAT AAA 34 4 8 Switch Off Timeouts Configuration dialog seeeeeeeeeeee nnn 36 4 8 1 Enable use of Open Window Switch off timeout function xx x xe e x e x x e cece eee es 36 4 8 2 Enable use of Occupancy function esseeeeeeeeeee enne nnn 37 4 8 3 Enable use of SLEEP timeout sxs e x e e x e e x e e K e e eee 40 4 9 Binary Input x Configuration dialog ccccccceee eee ee eee ee eens eeeeeeeeeeeeeeeeeeeeennnees 40 4 9 1 Enable use Of Input X sse 41 4 9 2 Genie inus eC 41 4 9 3 Debotulice TING aussexsaapsiacuiaiddqeses 259 dRET PE E
38. ait before switching off the AC unit 4 9 Binary Input x Configuration dialog Device 1 1 1 PA RC Interface garan Enable use of Input 1 Y t es v Mode Configuration Sarre dera n Special Modes Configuration Contact type NO Normally Open x Fan Speed Configuration GE A Vanes Up Down Configuration Debounce time 50 ms M Temperature Configuration UE T e Scene Configuration gt Disabling function Do N Switch Off Timeouts Configuration gt Function Switching Binary Input 1 Configuration Binary Input 2 Configuration gt Send telegram after Binary Input 3 Configuration bus recovery Binary Input 4 Configuration EU E MM REA Value on raising edge No action contact activated gt Value on falling edge No action contact deactivated EE gt Cyclical sending Never Figure 4 37 Binary Input Configuration dialog Intesis Software S L All rights reserved URL http www intesis com 40 60 u This information is subject to change without notice n te Sx i amp E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng All the parameters in this section are related with the binary inputs properties and communication objects 4 9 1 E
39. alue is returned through its bit type object 4 5 8 Enable use of Text object for Vane U D This parameter shows hides the Status Vanes U D Text communication object E 77 Status Vanes U D Text DPT 15 001 l4byte ASCII String o If set to no the object will not be shown o If set to yes the Status Vanes U D Text object will appear Also in the parameters will be shown seven text fields five for the Vane Position and one for the Auto function and another one for the Swing function that will let modify the text string displayed by the Status Vanes U D Text when changing a vane position String when vanes U D in AUTO U D AUTO String when vanes U D in POS 1 U D POS 1 String when vanes U D in POS 2 U D POS 2 String when vanes U D in POS 3 U D POS 3 String when vanes U D in POS 4 U D POS 4 Figure 4 19 Parameter detail Intesis Software S L All rights reserved a URL http www intesis com 29 60 This information is subject to change without notice n te Sx i em E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 6 Temperature Configuration dialog Device 1 1 1 PA RC Interface General Le Periodic sending of Status AC Setp 0 Mode Confi ti xu um en EE in seconds O No periodic sending Special Modes Configuration 4 Fan Speed Configuration Enable use of
40. and also monitor if there is a filter alarm E 29 Control Reset Filter DPT 1 015 1bit 1 Reset filter Fad 79 Status Filter Status DPT 1 005 1bit 0 No alarm 1 Alarm o If set to no the object will not be shown o If set to yes the Control Reset Filter y Status Filter Status objects will appear e The Status object will show a 0 value when there s no filter alarm and a 1 value when the filter is full Once the filter is cleaned the alarm can be reset by sending a 1 value to the Contro Reset Filter object 4 1 7 Enable object Error Code 2byte This parameter shows hides the Status Error Code communication object which shows the indoor unit errors if occurred in numeric format SH 81 Status Error Code 2byte 0 No error Any other see man o If set to no the object will not be shown o If set to yes the Status Error Code 2byte object will appear e This object can be read and also sends the indoor unit error if occurred in numeric format If a 0 value is shown that means no error Intesis Software S L All rights reserved URL http www intesis com 13 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 1 8 Enable object Error Text Code 14byte This parameter shows
41. ase HEAT or decrease COOL in Celsius Number of degrees Celsius that will increase in Heat Mode or decrease in Cool Mode while in Power Mode Fan Speed for this mode Fan Speed that will be set in the unit while in Power Mode Intesis Software S L All rights reserved URL http www intesis com 19 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 3 2 Enable use of ECONOMY mode This parameter shows hides the Control Econo Mode and Status Econo Mode communication objects The Econo Mode lets change the Setpoint Temperature and the Fan Speed within a given period of time a 36 Control Econo Mode DPT_1 010 1bit 0 Stop l1 Start a 84 Status Econo Mode DPT 1 001 1bit 0 Off 1 On o If set to no the objects will not be shown o If set to yes the Contro Econo Mode and Status Econo Mode objects and new parameters will appear e When a 1 value is sent to the Contro communication object EconoMode will be enabled and the Status object will return this value e When a O value is sent to the Contro communication object EconoMode will be disabled and the Status object will return this value A Important This mode will ONLY work if the indoor unit is both turned on and in a Heat Coo
42. asonic Application s Program Version 1 0 Order Code PA RC KNX 1i Intesis Software S L All rights reserved URL http www intesis com 3 60 e This information is subject to change without notice n te Sx i em E Email info intesis com ftw t IntesisBox is a registered trademark of Intesis Software SL sohware el 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng INDEX 1 PESCON c 6 2 CONOCIO oare E 7 2 1 PA RC KNX 1i without Panasonic Remote Controller ccc e e e e e ee 7 2 2 PA RC KNX 1i with Panasonic Remote Controller sse e ee x e e e eee 7 3 Configuration and SETUP 25 0neectaceesicsstantantnnenteesatansiataernaaniseeasentaseisiacesanmieteseneiasas 9 4 ET In S gectetadecatatacesanedadotanydceauntotedyeaestnaeucesdadutarsdaagecondadsequedasseneedan enue 10 4 1 GAFA lO E 11 4 1 1 Send READs for Control objects on bus recovery xe ee ee ee 11 4 1 2 Scene to load on bus recovery startup csssssseeeeeenn nnnm 11 4 1 3 Disallow control from remote controller eeeeeeeee enn 11 4 1 4 Enable func Control Lock Control Obj sssssseeeeeennnn mmn 12 4 1 5 Enable func Operating Hours Counter csxe e e e e e e ee 12 4 1 6 Enable use of objects TOF Filter 2csseciau tes Susie iw QE ari d aaa RR ur ia RR ta RR 13 4 1 7 Enable object Error Code 2byte
43. at will be activated on a rising edge This scene MUST be defined in the Scene Configuration dialog as a preset Intesis Software S L All rights reserved a URL http www intesis com 48 60 This information is subject to change without notice n te Sx i E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng o When Occupancy internal is selected the binary input x will have the same behavior as configured in the parameter Enable use of Occupancy function inside the Switch Off Timeouts Configuration dialog gt Function Occupancy internal lt Figure 4 49 Parameter detail o When Window Contact internal is selected the binary input x will have the same behavior as configured in the parameter Enable use of Open Window Switch off timeout function inside the Switch Off Timeouts Configuration dialog Function Window Contact internal Figure 4 50 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 49 60 u This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 5 Specifications Dimensions 70X70X28
44. counts the number of operating hours for the PA RC KNX 1i B 87 Status Operation Hour Counter DPT 7 001 2byte Number of operating hours o If set to no the object will not be shown Intesis Software S L All rights reserved URL http www intesis com 12 60 B This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng o If set to yes the Status Operation Hour Counter object will appear e This object can be read and sends its status every time an hour is counted The gateway keeps that count in memory and the status is sent also after a KNX bus reset failure Although this object is marked as a Status_ object it also can be written to update the counter when needed To reset the counter Should be written a O value A Important This object comes by default without the write W flag activated If is necessary to write on it this flag must be activated A Important This object will also return its status every time a value is written only if it s different from the existing one A Important If the stored value is O hours the gateway will not send the status to KNx 4 1 6 Enable use of objects for Filter This parameter shows hides Control Reset Filter and Status Filter Status that lets reset the filter status
45. ct 4 7 4 Scene x preset This parameter lets define a preset for a scene the following description is valid for all the scenes scene 1 preset yes scene will NOT be modifiable from KNX bus lt Figure 4 28 Parameter detail o If set to no the preset for the scene x will be disabled o If set to yes the preset will be enabled When a scene is executed the values configured in the preset will be aplied A Important If a scene s preset is enabled will not be possible to modify store the scene from the KNX bus gt Scene 1 Value for On Off ON gt Scene 1 Value for Mode COOL gt Scene 1 Value for Fan Speed FAN SPEED AUTO gt Scene 1 Value for Vanes U D unchanged if available gt Scene 1 Value for Setpoint Temp 18 0 DC gt Scene 1 Value for Remote Lock Locked remote not allowed Figure 4 29 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 34 60 u This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Scene x Value for On Off This parameter lets choose the power of the indoor unit when the scene is executed The following options are available ON OFF or unchanged gt
46. d on bus recovery startup This parameter executes a selected scene on bus recovery or startup only if the selected scene has an enabled preset or values previously saved from KNX bus see Scene Configuration dialog If the gateway is disconnected from the indoor unit the scene will not be applied even when connecting to the indoor unit again Scene to load on bus recovery startup scene 2 needs to define vals for that scene gua Figure 4 4 Parameter detail 4 1 3 Disallow control from remote controller This parameter allows 1 Having the remote controller always locked or 2 Decide through a new communication object if the RC is locked or not o If set to yes all the actions performed through the remote controller will be disabled Intesis Software S L All rights reserved URL http www intesis com 11 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng o If set to no the remote controller will work as usually It also appears a new parameter and the communication object Control Lock Remote Control e 33 Control Lock Remote Control DPT 1 002 Lbit 0 Unlocked 1 Locked Disallow control from remote controller no gt Enable comm obj Ctrl Remote Lock yes Figure 4 5
47. dow DPT 1 009 and O Stop 1 Start Timeout DPT 1 010 for the Control Switch Off Timeout gt Disallow On Off operation while window is Open If set to no On Off commands while the window is open will be accepted e Ifa 1 value is sent to the Control Switch Off Timeout object the switch off timeout period will begin again e If a O value is sent to the Control Switch Off Timeout object no action will be performed If set to yes On Off commands while the window is open will be saved but not applied These commands will be used in the next parameter if set to yes Reload last On Off val once window is closed If set to no once the switch off timeout is stopped any value will be reloaded If set to yes once the switch off timeout is stopped the last On Off value sent will be reloaded e If a 1 value is sent to the Control Switch Off Timeout object after the timeout period the indoor unit will turn on e If a O value is sent to the Control Switch Off Timeout after the timeout period no action will be performed 4 8 2 Enable use of Occupancy function This parameter shows hides the Contro Occupancy communication object which lets apply different parameters to the indoor unit depending on the presence no presence in the room 27 31 Control Occupancy DPT 1 018 1bit 0 Not Occupied 1 Occupied o If set to no the object will not be shown o If set to yes the Control Occupancy object and
48. e 1 Disable is selected the input can be disabled using the value 1 and enabled using the value 0 O Intesis Software S L All rights reserved URL http www intesis com 41 60 e This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 9 5 Function This parameter lets choose the function that will have the binary input There are 7 different functions available Switching Dimming Shutter Blind Value Execute Scene internal Occupancy internal and Window Contact internal o When Switching is selected the communication object and new parameters for the Input x will appear as shown below B 89 Status Inl Switching DPT_1 001 1bit 0 Off1 On Function Switching gt Send telegram after No action bus recovery i oo Value on raising edge Toggle On Off 7 contact activated m LZ gt Value on falling edge No action contact deactivated gt Cyclical sending Never 7 Figure 4 38 Parameter detail Send telegram after bus recovery This parameter lets select if the Binary Input x will send a telegram or not after a bus recovery and the type of telegram sent if enabled e When No action is selected no telegram will be sent aft
49. e objects for Auto Heat Cool Fan and Dry will appear When enabled a mode will return a 1 through its bit type object 4 2 8 Enable use of Text object for Mode This parameter shows hides the Status Mode Text communication object Intesis Software S L All rights reserved URL http www intesis com 17 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng S 62 Status Mode Text DPT 16 001 14byte ASCII String o If set to no the object will not be shown o If set to yes the Status_ Mode Text object will appear Also in the parameters will be shown five text fields one for each mode that will let modify the text string displayed by the Status_ Mode Text when changing mode gt String when mode is AUTO AUTO gt String when mode is HEAT HEAT if available gt String when mode is COOL COOL gt String when mode is FAN FAN gt String when mode is DRY DRY Figure 4 8 Parameter detail 4 3 Special Modes Configuration dialog Device 1 1 1 PA RC Interface General Enable use of POWER mode No x Mode Configuration Special Modes Configuration Enable use of ECONOMY mode No X Fan Speed Configuration ee Vanes Up Down Configuration Enable use of ADDITIONA
50. enabled yes or disabled no for the Control Fan Speed object Only if Roll over is enabled gt AUTO FSi gt FS2 AE FS3 Only if Roll over is enabled Up Increase Down Decrease 4 4 4 Enable use of bit tyoe Fan Speed objects for Control This parameter shows hides the bit type Control_ Fan Speed objects B 13 Control Fan Speed 1 DPT 1 002 1bit 1 Set Fan Speed 1 gl 14 Control Fan Speed 2 DPT 1 002 1bit 1 Set Fan Speed 2 B 15 Control Fan Speed 3 DPT 1 002 1bit 1 Set Fan Speed 3 o If set to no the objects will not be shown o If set to yes the Control Fan Speed objects for Speed 1 Speed 2 and Speed 3 will appear To activate a Fan Speed by using these objects a 1 value has to be sent 4 4 5 Enable use of bit type Fan Speed objects for Status This parameter shows hides the bit type Status Fan Speed objects B 65 Status Fan Speed 1 DPT 1 002 1bit 1 Fan in Speed 1 a 66 Status Fan Speed 2 DPT 1 002 1bit 1 Fan in Speed 2 B 67 Status Fan Speed 3 DPT 1 002 1bit 1 Fan in Speed 3 Intesis Software S L All rights reserved URL http www intesis com 24 60 u This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng
51. er a bus recovery e When Current status is selected the binary input will send a telegram with its current status after a bus recovery Also a new parameter will appear see below e When On is selected the binary input will send a telegram with a 1 value after a bus recovery Also a new parameter will appear see below e When Off is selected the binary input will send a telegram with a O value after a bus recovery Also a new parameter will appear see below dd gt Sending delay after 10 bus recovery seconds Figure 4 39 Parameter detail Sending delay after a bus recovery seconds This parameter lets configure a delay in seconds that will be applied after a bus recovery and after which a telegram will be sent O Intesis Software S L All rights reserved URL http www intesis com 42 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Value on rising edge This parameter lets select the value that the Binary Input x will send on a rising edge contact activated e When On is selected the binary input will always send telegrams with a 1 value e When Off is selected the binary input will always send telegrams with a O value e When Toggle On
52. esent and connected to the A B bus this one have ALWAYS to be set up as Master e To check if the RC is in Master or Slave mode it has a switch on the back This switch should always be placed in MASTER position Figure 2 1 Panasonic RC PCB backside M S switch Disconnect mains power from the AC unit and use a 2 wire cable with a diameter of 0 75mm to 1 25mm for the connection of PA RC KNX 1i Panasonic remote controller and its corresponding indoor unit Screw the suitably peeled cable ends in the corresponding X Y terminals of each device as summarized in the Figure 2 2 Maximum A B bus length is 200 meter Cable has no polarity Connection of the PA RC KNX 1i to the KNX bus Disconnect power of the KNX bus Connect the PA RC KNX 1i to the KNX TP 1 EIB bus using the KNX standard connector red grey of the PA RC KNX 1i respect polarity Reconnect power of the KNX bus and mains power of the AC unit Intesis Software S L All rights reserved URL http www intesis com 7 60 u This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Connection diagrams PA RC KNX 1i without Panasonic RC Binary inputs for potential free contacts IntesisBox r i i KNX TP 1 died REPRE NS m EIB bus Internal
53. eter will appear see below e When Off is selected the binary input will send a telegram with a 0 value after a bus recovery Also a new parameter will appear see below gt Sending delay after 10 bus recovery seconds Figure 4 42 Parameter detail gt Sending delay after a bus recovery seconds This parameter lets configure a delay in seconds that will be applied after a bus recovery and after which a telegram will be sent Intesis Software S L All rights reserved URL http www intesis com 44 60 u This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Mode for short long operation This parameter lets select the value that the Binary Input x will send on a rising edge contact activated for a short and a long operation e When On increase is selected the binary input will always send telegrams with a 1 value for a short operation and an increase step for a long operation e When Off decrease is selected the binary input will always send telegrams with a O value for a short operation and an decrease step for a long operation e When Toggle On Off increase decrease is selected o For the short operation the binary input will send a 1 value after a
54. f telegram sent if enabled e When No action is selected no telegram will be sent after a bus recovery e When Fixed value is selected the binary input will send a telegram with the same value configured in the Value on rising edge parameter Also a new parameter will appear see below dd Sending delay after 10 bus recovery seconds Figure 4 46 Parameter detail Sending delay after a bus recovery seconds This parameter lets configure a delay in seconds that will be applied after a bus recovery and after which a telegram will be sent gt DPT to be sent This parameter lets select the DPT type for the value that will be defined in the next parameter This value will be sent on a rising edge contact activated DPT to be sent DPT 12 001 4byte Figure 4 47 Parameter detail gt Value on rising edge when contact activated This parameter lets define a value for the DTP type configured in the DPT to be sent parameter This value will be sent on a rising edge contact activated o When Execute Scene internal is selected the binary input x will activate the scene defined in the next parameter on a rising edge contact activated gt Function Execute scene internal gt Scene when contact is activated Scene l needs to be defined a Figure 4 48 Parameter detail gt Scene when contact is activated This parameter lets choose the scene th
55. ge contact activated e When Up is selected the binary input will always send telegrams with a o e When Down is selected the binary input will always send telegrams with a 1 value Intesis Software S L All rights reserved URL http www intesis com 46 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng e When Toggle Up Down is selected the binary input will send a O value after a 1 value and viceversa Method This parameter lets select the working method for the shutter blind e When Step Move Step is selected On a rising edge contact activated a step stop telegram will be sent and will begin a time called T1 If a falling edge occurs contact deactivated during the T1 no action will be performed If the rising edge is maintained longer than T1 a move telegram will be sent and will start a time called T2 If a falling edge occurs during the T2 a step stop telegram will be sent If a falling edge occurs after T2 no action will be performed e When Move Step is selected On a rising edge a move telegram will be sent and will begin the T2 time If a falling edge occurs during the T2 a step stop telegram will be sent If a falling edge occurs after T2 no action will
56. he action specified in the next parameter Action after timeout elapsed gt Action after timeout elapsed When Switch Off is selected once the timeouthas elapsed the indoor unit will turn off When Apply Preset Delta is selected once the timeout configured is extinguished a delta temperature will be applied decreasing the setpoint when in Heat mode or increasing the setpoint when in Cool mode Also new parameters will appear gt Temp delta decrease HEAT or increase COOL C This parameter lets configure the delta temperature that will be applied when the timeout is extinguished A Important When there is occupancy again after the application of a delta the same delta will be applied inversely as explained above gt Disallow On Off operation while not Occupied If set to no On Off commands while the window is open will be accepted e Ifa 1 value is sent to the Contro Occupancy object the switch off timeout period will begin again e If a O value is sent to the Control Occupancy object no action will be performed If set to yes On Off commands while not occupied will be saved but not applied These commands will be used in the next parameter if set to yes gt Reload last On Off value yes when Occupied gt Disallow On Off operation while yes not Occupied Figure 4 35 Parameter detail Reload last On Off value when Occupied If set to no once the switch off
57. hides the Status_ Error Text Code communication object which shows the indoor unit errors if occurred in text format E 82 Status Error Text Code DPT 16 001 14byte 3 char MH Error Empty None o If set to no the object will not be shown o If set to yes the Status_ Error Text Code object will appear e This object can be read and also sends the indoor unit error if occurred in text format The errors shown have the same format as at the remote controller and at the error list from the indoor unit manufacturer If the object s value is empty that means no error 4 2 Mode Configuration dialog Device 1 1 1 PA RC Interface General Ind it has HEAT mod No x Mode Configuration eee ba see docum for your indoor unit Special Modes Configuration Fan Speed Configuration When mode is AUTO Status_ objs report No v Vanes Up Down Configuration actual operating status HEAT COOL Temperature Configuration Enable PID Compat Scaling Mode objects No M Scene Configuration for Control Switch Off Ti ts Confi ti witc imeouts Configuration ple use of object for Mode Yes Binary Input 1 Configuration Binary Input 2 Configuration gt DPT type for Mode Object 0 Decrease 1 Increase DPT 1 007 v Binary Input 3 Configuration Binary Input 4 Configuration Enable use of bit type Mode objects No 7 for Control Enable use of bit type Mode objects No x f
58. imultaneously by the wired remote control of the AC unit and by KNX e Total Control and Monitoring of the AC unit from KNX including monitoring of AC unit s state of internal variables running hours counter for filter maintenance control and error indication and error code e Up to 5 scenes can be saved and executed from KNX fixing the desired combination of Operation Mode Set Temperature Fan Speed Vane Position and Remote Controller Lock in any moment by using a simple switching e Four binary inputs for potential free contacts provide the possibility to integrate many types of external devices Also configurable from ETS they can be used for switching dimming shutter blind control and more Intesis Software S L All rights reserved URL http www intesis com 6 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 2 Connection Connection of the PA RC KNX 1i to the AC indoor unit 2 1 PA RC KNX 1i without Panasonic Remote Controller The PA RC KNX 1i can be connected directly to the A B bus of the indoor unit no Panasonic remote controller RC from now on also connected in the A B bus See connection diagram below 2 2 PA RC KNX 1i with Panasonic Remote Controller If a Panasonic remote controller RC is pr
59. indoor side 2701 Sepa ann DANE SSOnnecuon Emor Indoor outdoor unit connection wire indoor side F27 Indoor outdoor unit connection cable and 2701 Indoor outdoor unit disconnection problem connection terminals or outdoor unit power supplies outdoor side 2701 Indoor outdoor unit connection error Indoor outdoor unit connection wire outdoor problem side Total capacity for the number of indoor units is 3001 System problem insufficient or over Check the total capacity and the number of indoor units F30 Check the main power supply terminal board 3001 Open phase or reversed phase of supply connections or switch over any two of the power supply wires 3101 Suction pressure protection Insufficient refrigerant or valve operation closed F31 3101 High pressure cut off Check the Refrigeration system 3101 4 way valve problem Check the 4 way valve or lead wire Intesis Software S L All rights reserved URL http www intesis com 52 60 u This information is subject to change without notice n te x i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL bannig 34 938047134 Indoor gateway connection wire IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Refrigerant system problem Valve operation closed or refrigerant system Compressor overcurrent protection Open phase or lock in compressor Compressor discharge temp protection Insufficient refrigerant Outdo
60. ion object which lets change the indoor unit setpoint temperature by using two different datapoint types B 27 Control Setpoint Temp DPT 1 007 1bit 0 Decrease 1 Increase o If set to no the object will not be shown o If set to yes the Control Setpoint Temp object and a new parameter will appear Enable use of obj for Setp Temp yes gt DPT type for Setp Temp object Up 1 Down DPT 1 008 Figure 4 22 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 30 60 u This information is subject to change without notice n te Sx i E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt DPT type for Setp Temp object This parameter lets choose between the datapoints O Up 1 Down DPT 1 008 and O Decrease 1 Increase DPT 1 007 for the Control Setpoint Temp object Lower limit 16 C 17 C gt 30 C 31 C Upper limit Up Increase Down Decrease 4 6 3 Enable limits on Control Setpoint obj This parameter enables to define temperature limits for the Control Setpoint Temperature object Enable limits on Control_ Setpoint obj Yes gt Lower limit C 19 0 ec gt Upper limit 2C 28 0 C Figure 4 23 Parameter detail o If set to no the setpoint temperature limits
61. is Software S L All rights reserved URL http www intesis com 10 60 u This information is subject to change without notice n te Sx LS E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL sowe 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 1 General dialog Inside this parameter s dialog it is possible to activate or change the parameters shown in the Figure 4 1 The first field shows the URL where to download the database and the user manual for the product 4 1 1 Send HEADS for Control objects on bus recovery When this parameter is enabled PA RC KNX 1i will send READ telegrams for the group addresses associated on its Control objects on bus recovery or application reset start up o If set to no the gateway will not perform any action o If set to yes all Contro objects with both Transmit T and Update U flags enabled will send READs and their values will be updated with the response when received 4 7 send READs for Control objects on bus yes recovery T and U flags must be active gt Delay before sending READs sec 30 Figure 4 3 Parameter detail gt Delay before sending READs sec With this parameter a delay can be configured between O and 30 seconds for the READs sent by the Contro _ objects This is to give time enough to other KNX devices on the bus to start up before sending the READs 4 1 2 Scene to loa
62. l Auto Heat or Auto Cool Mode Action time for this mode minutes Duration of EconoMode in minutes once started Setpoint delta increase HEAT or decrease COOL in Celsius Number of degrees Celsius that will increase in Heat Mode or decrease in Cool Mode while in EconoMode Fan Speed for this mode Fan Speed that will be set in the unit while in EconoMode 4 3 3 Enable use of ADDITIONAL HEATING mode This parameter shows hides the Control Start Additional Heat Mode and Status Additional Heat Mode communication objects The Additional Heating Mode lets change the Setpoint Temperature and the Fan Speed within a given period of time a 37 Control Additional Heat DPT_1 010 1bit 0 Stop 1 Start a 85 Status Additional Heat DPT 1 001 1bit OffF 1 On o If set to no the objects will not be shown o If set to yes the Control Start Additional Heat Mode and Status Additional Heat Mode objects and new parameters will appear Intesis Software S L All rights reserved u URL http www intesis com 20 60 This information is subject to change without notice n te Sx i em E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng e When a 1 value is sent to the Contro _ communication object Additional Heating Mode will be enabled and the Status object will return this value
63. mm gt SSS Weight 70 00000000 Power suppl L PPY Supplied through KNX bus Voltage 13 15V Panasonic A B Bu MM OA LED indicators 1 x KNX programming 1 x KNX programming Push buttons 4 x Potential free binary inputs Signal cable length 5m uschielded may be extended up to 20m with twisted Binary inputs Compliant with the following standards IEC61000 4 2 level 4 15kV air discharge 8kV contact discharge MIL STD 883E Method 3015 7 class3B Configuration Configuration with ETS Operating pe Temperature From 25 C to 85 C Storage o o Temperature From 40 C to 85 C Isolation Voltage 2500V Compliant with RoHS directive 2002 95 CE CE conformity to EMC directive 2004 108 EC and Low voltage directive 2006 95 EC EN 61000 6 2 EN 61000 6 3 EN 60950 1 EN 50491 3 EN 50090 2 2 EN 50428 EN 60669 1 EN 60669 2 1 Certifications KNX bus Binary inputs connection 70 mm Programming LED Programming button AC Indoor unit A B bus connection Intesis Software S L All rights reserved URL http www intesis com 50 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 6 AC Unit Types compatibility A list of Panasonic indoor unit models compatible wi
64. nable use of Input x This parameter enables the use of the Input x and shows hides the Status Inx communication object s which will act as configured in the Function parameter e 89 Status Inl Switching DPT_1 001 1bit 0 Off 1 On a 91 Status In2 Switching DPT_1 001 1bit 0 Off 1 On B 93 Status In3 Switching DPT 1 001 1bit 0 Off1 On B 95 Status In4 Switching DPT 1 001 1bit 0 Off 1 On o If set to no the objects will not be shown o If set to yes the Status Inx object s and new parameters will appear 4 9 2 Contact type This parameter lets choose the behavior that will have the binary input depending on if the contact is normally open or normally closed o There are two possible options to configure the contact type NO Normally Open and NC Normally Closed 4 9 3 Debounce time This parameter lets choose a debounce time in milliseconds that will be applied to the contact 4 9 4 Disabling function This parameter shows hides the Control Disable Input x communication object which will let disable enable the input x B 50 Control Disable Input 1 DPT 1 003 1bit 0 Disable 1 Enable B 50 Control Disable Input 1 DPT 1 002 1bit 0 Enable 1 Disable o If set to no any object will be shown o When DPT 1 003 O Disable 1 Enable is selected the input can be disabled using the value O and enabled using the value 1 o When DPT 1 002 O Enabl
65. new parameters will appear If a 1 value is sent to this object no room occupancy the timeout will begin If a O value is sent to this object the timeout will stop Enable use of Occupancy function yes gt Timeout to apply action minutes 2 gt Action after timeout elapsed Apply Preset Delta Figure 4 32 Parameter detail Intesis Software S L All rights reserved URL http www intesis com 37 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng gt Timeout to apply action minutes This parameter lets choose how much time to wait in minutes before executing the action specified in the next parameter Action after timeout elapsed gt Action after timeout elapsed When Switch Off is selected once the timeout has elapsed the indoor unit will be turned off When Apply Preset Delta is selected once the timeout has elapsed a delta temperature will be applied in order to save energy decreasing the setpoint when in Heat mode or increasing the setpoint when in Cool mode Also new parameters will appear gt Temp delta decrease HEAT or 2 0 C increase COOL 9C nc AH eid Enable secondary timeout yes Figure 4 33 Parameter detail Temp delt
66. ning mode will only show Auto enabled o If set to yes when the indoor unit is set to Auto mode all the Status_ objects concerning mode will show the real mode which the machine is working Cool Heat Dry Fan In case of the bitfield objects also the Status Mode Auto will be shown enabled with a 1 value 4 2 3 Enable use of Heat Cool bit type obj This parameter shows hides the Contro and Status Mode Cool Heat communication objects 2 2 Control Mode Cool Heat DPT 1 100 1bit 0 Cool 1 Heat B 56 Status Mode Cool Heat DPT 1 100 1bit 0 Cool 1 Heat gt o If set to no the objects will not be shown o If set to yes the Control and Status Mode Cool Heat objects will appear e When a 1 value is sent to the Contro communication object Heat mode will be enabled in the indoor unit and the Status_ object will return this value e When a O value is sent to the Contro communication object Cool mode will be enabled in the indoor unit and the Status object will return this value 4 2 4 Enable PID Compat Scaling Mode Objects This parameter shows hides the Control Mode Cool amp On and Control Mode Heat amp On communication objects B 3 Control Mode Cool amp On DPT 5 001 1byte 0 0Off0 1 100 0n Cool B 4 Control Mode Heat amp On DPT 5 001 1byte 0 Off0 1 100 On Heat o If set to no the objects will not be shown o If set to yes the Control Mode Co
67. nual r0 eng The sequence followed when using this object is shown below AUTO HEAT COOL P 7 PE I 4 FAN aE DRY lt Up Increase Down Decrease If available A Important Read the documentation of your indoor unit to check if it has HEAT mode available 4 2 6 Enable use of bit type Mode objects for control This parameter shows hides the bit type Control Mode objects 2 5 Control Mode Auto DPT 1 002 1bit 1 Set AUTO mode LE 6 Control Mode Heat DPT 1 002 1bit 1 Set HEAT mode B 7 Control Mode Cool DPT 1 002 1bit 1 Set COOL mode B 8 Control Mode Fan DPT 1 002 1bit 1 Set FAN mode 2 9 Control Mode Dry DPT 1 002 1bit 1 Set DRY mode o If set to no the objects will not be shown o If set to yes the Control Mode objects for Auto Heat Cool Fan and Dry will appear To activate a mode by using these objects a 1 value has to be sent 4 2 Enable use of bit type Mode objects for status This parameter shows hides the bit type Status Mode objects B 57 Status_ Mode Auto DPT 1 002 1brt 1 AUTO mode is active B 58 Status Mode Heat DPT 1 002 Lbit 1 HEAT mode is active B 59 Status Mode Cool DPT 1 002 1bit 1 COOL mode is active B 60 Status Mode Fan DPT 1 002 1bit 1 FAN mode ts active 2 61 Status Mode Dry DPT 1 002 1bit 1 DRY mode is active o If set to no the objects will not be shown o If set to yes the Status Mod
68. ol amp On and Control Mode Heat amp On objects will appear e These objects provide compatibility with those KNX thermostats that control the demand of heating or cooling by using scaling percentage objects In Intesis Software S L All rights reserved URL http www intesis com 15 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng these thermostats the percentage demand is meant to be applied on a fluid valve of the heating cooling system e PA RC KNX 1i device does not provide individual control on the internal parts of the indoor unit as can be its compressor refrigerant valves etc Rather it provides the same level of control as a user remote controller e Objects Control Mode Cool amp On and Control_ Mode Heat amp On intend to bring compatibility between thermostats oriented to the control of custom heating cooling systems and ready made AC indoor units by applying the following logic e Whenever a non zero value gt 0 is received at Control Mode Cool amp On indoor unit will switch On in COOL mode e Whenever a non zero value gt 0 is received at Control Mode Heat amp On indoor unit will switch On in HEAT mode e Lastest updated object will define the operating mode e Indo
69. or Status Enable use of Text object for Mode No x Figure 4 6 Default Mode Configuration dialog All the parameters in this section are related with the different mode properties and communication objects B 1 Control Mode DPT 20 105 1byte 0 Aut 1 Hea 3 Coo 9 Fan 14 Dry The byte type communication object for Mode works with the DTP 20 105 Auto mode will be enabled with a O value Heat mode with a 1 value Cool mode with a 3 value Fan mode with a 9 value and Dry mode with a 14 value 4 2 1 Indoor unit has HEAT mode This parameter has to be used to indicate if the indoor unit has the heat mode available o If set to no the indoor unit doesn t have the heat mode available o If set to yes the infoor unit has the heat mode available Intesis Software S L All rights reserved URL http www intesis com 14 60 u This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng A Important Read the documentation of your indoor unit to check if it has HEAT mode available 4 2 2 When mode is AUTO Status objs report actual operating status This parameter shows the real status of the indoor unit when Auto mode is enabled o If set to no when the indoor unit is set to Auto mode all the Status_ objects concer
70. or heat exchanger outlet Outdoor heat exchanger outlet temperature temperature sensor problem sensor COND TEMP lead wire connector Compressor discharge temperature Compressor discharge temperature sensor DIS sensor problem T TEMP lead wire connector High pressure switch open circuit problem High pressure switch lead wire connector Low pressure sensor lead wire connector or Low pr i ow pressure sensor problem valve operation closed Current detector open circuit Outdoor unit current detector fault or connector Compressor internal protector worked Compressor fault or refrigeration system In case you detect an error code not listed contact your nearest Panasonic technical support service for more information on the error meaning Intesis Software S L All rights reserved URL http www intesis com 53 60 u This information is subject to change without notice n te Sx i LS E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Appendix A Communication Objects Table wire Lo feomaovor sae ome um wir jemem oo x emoce ies EIH es 3 ea ofan or a jeweceesaos rove orrs sm r mcomememm mema 8 eana sae mem some wir ae sena tee mem amma wir e eana am mem aw wir ae 70000000 sena ame mem Dum wir om 0000 eana ame mem Dum wir ow
71. or unit will switch off only when both objects become zero 0 or when an OFF is requested at object 0 On Off DPT 1 001 1bit Tm Important These objects function is only to send On Off and Cool Heat to the indoor unit The PID Inverter system is calculated by the indoor unit itself Please consider introducing an appropriate PID configuration to the external KNX thermostat to not interfere the indoor unit PID 4 2 5 Enable use of object for Mode This parameter shows hides the Control Mode communication object which lets change the indoor unit mode by using two different datapoint types LEN 10 Control Mode DPT 1 007 1bit 0 Decrease 1 Increase o If set to no the object will not be shown o If set to yes the Control Mode object and a new parameter will appear Enable use of object for Mode yes gt DPT type for Mode Object 0 Up 1 Down DPT 1 008 Figure 4 7 Parameter detail gt DPT type for Mode Object This parameter lets choose between the datapoints O Up 1 Down DPT 1 008 and O Decrease 1 Increase DPT 1 007 for the Control Mode object Intesis Software S L All rights reserved URL http www intesis com 16 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s ma
72. ore Scene objects for storing scenes will appear To store a scene by using these objects a 1 value has to be sent to the scene s object we want to store i e to store scene 4 a 1 has to be sent to the Control Store Scene 4 object Intesis Software S L All rights reserved URL http www intesis com 33 60 a This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 4 7 3 Enable use of bit objects for scene execution This parameter shows hides the Control Execute Scene bit type communication objects LE 45 Control Execute Scene 1 DPT 1 002 1bit 1 Execute Scene 1 LE 46 Control Execute Scene 2 DPT 1 002 1bit 1 Execute Scene 2 LE 47 Control Execute Scene 3 DPT 1 002 1bit 1 Execute Scene 3 B 48 Control Execute Scene 4 DPT 1 002 1bit 1 Execute Scene 4 B 49 Control Execute Scene 5 DPT_1 002 1bit 1 Execute Scene 5 Enable use of bit objects yes for scene execution nn Figure 4 27 Parameter detail o If set to no the communication objects will not be shown o If set to yes the communication objects will appear To execute a scene by using these objects a 1 value has to be sent to the scene s object we want to execute i e to execute scene 4 a 1 has to be sent to the Control Execute Scene 4 obje
73. r Status Enable use of Text object for Fan Speed No x Figure 4 11 Default Fan Speed Configuration dialog All the parameters in this section are related with the Fan Speed properties and communication objects 4 4 1 When fan is AUTO Status_ objs report actual operating status speed1 2 This parameter shows the real fan status of the indoor unit when Auto fan mode is enabled o If set to no when the indoor unit is set to fan Auto mode all the Status_ objects concerning fan will only show Auto enabled o If set to yes when the indoor unit is set to fan Auto mode all the Status_ objects concerning mode will show the real fan mode which the machine is working Speed 1 Speed 2 etc In case of the bitfield objects also the Status_ Fan Speed Manual Auto will be shown enabled with a 1 value When fan is AUTO Status objs report No actual operating status speed1 2 Figure 4 12 Parameter detail 4 4 2 DPT object type for fanspeed With this parameter is possible to change de DPT for the Control Fan Speed and Status Fan Speed byte type communication objects Datapoints Scaling DPT 5 001 and Enumerated DPT 5 010 can be selected A Important The communication objects shown in this section may be different depending on the number of fan speeds available although they all share the same communication object number Intesis Software S L All rights reserved URL http www intesis com 22
74. re 4 1 Default parameter configuration With this configuration it s possible to send On Off Control_ On Off change the AC Mode Control Mode the Fan Speed Control Fan Speed and also the Setpoint Temperature Control_ Setpoint Temperature The Status_ objects for the mentioned Control_ objects are also available to use if needed Also objects Status_ AC Return Temp and Status_ Error Alarm are shown 4 1111 PA RC Interface 270 Control On Off DPT 1 001 1bit 0 OfF1 On R 1 Control Mode DPT 20 105 1byte 0 Aut 1 Hea 3 Coo 9 Fan 14 Dry Fd 10 Control Mode DPT 1 007 bit 0 Decrease 1 Increase a 11 Control Fan Speed 3 Speeds DPT 5 010 1byte Speed values 1 2 3 R 17 Control_ Vanes U D 4 Pos DPT 5 010 1byte Position values 1 2 3 4 2726 Control Setpoint Temperature DPT 9 001 2byte C RI 39 Control Execute Scene DPT 18 001 1byte 0 4 Execute Scene 1 5 a 54 Status On Off DPT 1 001 1bit 0 Off 1 On 2 55 Status Mode DDT 20 105 1byte 0 Aut 1 Hea 3 Coo 9 Fanz14 Dry 2 63 Status Fan Speed 3 Speeds DPT 5 010 1byte Speed Values 1 2 3 a 69 Status Vanes U D 4 Pos DPT 5 010 1byte Position values 1 2 3 4 8778 Status AC Setpoint Temp DPT 3 001 2byte C R 80 Status_ Error Alarm DPT 1 005 1bit 0 No alarm 1 Alarm a 88 Status Current Scene DPT 17 001 1byte 0 4 Scene X 1 63 No Scene Figure 4 2 Default communication objects Intes
75. rtant When a scene is executed Status Current Scene object shows the number of this scene Any change in previous items does Status Current Scene show No Scene Only changes on items marked as unchanged will not disable current scene Intesis Software S L All rights reserved URL http www intesis com 35 60 B This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL ote 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 48 Switch Off Timeouts Configuration dialog Device 1 1 1 PA RC Interface General Enable use of Open Window Switch off No Mode Configuration See ee ee Special Modes Configuration Fan Speed Configuration Enable use of Occupancy function No 7 Vanes Up Down Configuration y RS Enable use of Sleep function No Temperature Configuration Scene Configuration Switch Off Timeouts Configuration Binary Input 1 Configuration Binary Input 2 Configuration Binary Input 3 Configuration Binary Input 4 Configuration Figure 4 30 Default Switch Off Timeouts Configuration dialog All the parameters in this section are related with the timeout properties and communication objects 4 8 1 Enable use of Open Window Switch off timeout function This parameter shows hides the Control Switch Off Timeout communication object which lets Start Stop a
76. s Additional Cool DPT Switch rl 0 Off 1 On Status_ Operation Hour Counter 2 byte DPT Value 2 Ucount 7 001 Yl Number of operating hours 88 Status_ Current Scene 1 byte DPT_SceneNumber 17 001 RI tf O to 4 Scene 1 to 5 63 No Scene Status_ Inx POP TT 1 bit DPT Switch 1 001 Wr 0 Off 1 On uiIe Status_ Status Inx Dimming On off On Off Abit DPT DPT Switch 1000 o Off 1 On Status Inx Shut Blind Step DPT ShutterBlinds 1 023 a 0 Step Up 1 Step Down Status Inx Status_ Inx Value 1 A byte DPT Value 1 Ucount 5 010 R r 1 byte unsigned value Intesis Software S L All rights reserved URL http www intesis com 59 60 This information is subject to change without notice M t Email info intesis com IntesisBox is a registered trademark of Intesis Software SL n esis E tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng ana mvae sene orvan z ocne nm fa wem eme zove orr vane came em r r wemenme eme rove mes wm e e emeeeem 0000 ona mcv sove or vanea ucne 1201 e r jeweemer Status_ Inx Dimming Step 1 bit DPT_Control_Dimm 3 007 au Dimming step Status Inx Shut Blind Move DPT ShutterBlinds 1 023 r fo Move up 1 movepown 000 0 Move Up 1 Move Down Intesis Software S L All rights reserved URL http www intesis com 60 60 This information is subject to change without notice n tes l E Email
77. th PA RC KNX 1i and their available features can be found in http www intesis com pdf IntesisBox PA RC xxx 1 AC Compatibility pdf Intesis Software S L All rights reserved URL http www intesis com 51 60 e This information is subject to change without notice n te Sx i em E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL sowe 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng 7 Error Codes Error code KNX RC Display object Location or problem Check location 65535 1 if Error in the communication of PA AC KNX 1i signed device with the AC unit Drain pump and drain pipe indoor unit F15 1501 Drain level Float switch problem Brac Sa Louver motor decorative panel connection EIS 100 Louver switch problem terminal or indoor unit louver motor connectors Indoor unit D C Fan motor or connection F17 1701 D C Fan motor problem temials Indoor temperature sensor lead wire or indoor 2001 Indoor temperature sensor problem unit connector F20 2010 Remote control thermistor problem Remote control thermistor F21 2101 Pipe temp sensor problem Pipe temperature sensor lead wire or indoor unit indoor unit connector F26 2601 Remote control transmission Remote control unit cable and connection problem terminals Indoor outdoor unit connection cable and 2701 Indoor outdoor unit disconnection problem connection terminals or indoor unit power supplies
78. timeout has elapsed any value will be reloaded If set to yes once the switch off timeout has elapsed the last On Off value will be reloaded Intesis Software S L All rights reserved u URL http www intesis com 39 60 This information is subject to change without notice n te Sx i em E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL ote tel 34 938047134 IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng e If a 1 value is sent to the Control Occupancy object after the timeout period the indoor unit will turn on e If a O value is sent to the Control Occupancy after the timeout period no action will be performed 4 8 3 Enable use of SLEEP timeout This parameter shows hides the Control Sleep Timeout communication object which lets start a timeout to automatically turn off the indoor unit B 32 Control Sleep Timeout DPT 1 010 1bit 0 Stop 1 Start o If set to no the object will not be shown o If set to yes the Control_ Sleep Timeout object and a new parameter will appear If a 1 value is sent to this object the switch off timeout will begin If a 0 value is sent to this object the switch off timeout will stop Enable use of SLEEP timeout yes gt Sleep function switch off timeout 1 minutes LT Figure 4 36 Parameter detail Timeout to apply action minutes This parameter lets select how much time in minutes to w
79. to check if Up Down Vanes are available 4 5 2 Available AUTOs in Indoor Unit This parameter lets choose if the indoor unit has only 1 AUTO mode or 3 different AUTO modes Available AUTOs in Indoor Unit i see docum for your indoor unit D Figura 4 17 Detalle del par metro A Important Read the documentation of your indoor unit to check how many AUTO modes are available 4 5 3 DPT object type for Vanes Up Down With this parameter is possible to change de DPT for the Contro Vanes U D and Status Vanes U D byte type communication objects Datapoints Scaling DPT 5 001 and Enumerated DPT 5 010 can be selected A Important The communication objects shown in this section may be different depending on the number of vanes position available although they all share the same communication object number o When Enumerated DPT 5 010 is selected Control_ Vanes U D and Status Vanes U D communication objects for this DPT will appear 2 17 Control Vanes U D 4 Pos DPT 5 010 1byte Position values 1 2 3 4 S 69 Status_ Vanes U D 4 Pos DPT 5 010 1byte Position values 1 2 3 4 To choose a vanes position values from 1 to 4 can be sent to the Control object Each value will correspond to the position i e Value 3 Position 3 Intesis Software S L All rights reserved URL http www intesis com 26 60 B This information is subject to change without notice n te Sx i em E Email info intesis
80. tware S L All rights reserved URL http www intesis com 55 60 This information is subject to change without notice M t Email info intesis com IntesisBox is a registered trademark of Intesis Software SL n esis E tel 34 938047134 k d IntesisBox KNX Panasonic AC FS FSM User s manual r0 eng Control Vanes U D 1 bit DPT UpDown 1 008 0 Up 1 Down W Um ems ime a coma suoma re comme roer u jeseemei eme 0 ampere U aaae ime fw ocw 0 ae emoon see momen sm wir eo ae emere am omes sos wir pemem o con winaon comessas soe srraeeee ime wi foroven emecsenormem soe mme ime wm jemermm 700000 x ewe am emos ims Jjocmomenicmuem m feoma seein am ome roio wrjemeesxe 000000 m feomarwatenatecome oam orreen ro wla Jememennsem o ewruecmeoues am omeo seer pr onus uses D feomarowervase am mmm so wir jemeeme 700000 arena re oreson roo wm jemersm 000 emeomeasn soe mme ro wIm jemersm 000000 cona naano soe mme roo w r jemersm 00000 0 to 4 Exec Scene 1 to 5 Control Save Exec Scene IE 128 to 132 Save Scene 1 to 5 Control Store Scenel DPT Bool 1 002 ETE 1 Store Scene Control Store Scene2 DPT Bool 1 002 fw 1 Store Scene Intesis Software S L All rights reserved URL http www intesis com 56 60 This information is subject to change without notice n tes i S E Email info intesis