Home

Weather Center

image

Contents

1. 1 Display unit 2 3 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Power adapter 6 Instruction Manual IMPORTANT service PRODUCT REGISTRATION SUPPORT to receive year warranty protection Products www AcuRite com Register a Product Features amp Benefits 3 in SENSOR 5 Mounting Hardware Includes anchors and screws Qty Diameter Length 1 Temperature amp Humidity Sensors internal 4 4 1 2 Release Lever for Battery Access 1 8 1 4 or 3 8 3 Mounting Point 6 Mounting Bracket 4 Wind Speed Anemometer 7 A B C Switch not shown ID code that must match display s A B C switch to ensure units synchronize Features amp Benefits DISPLAY UNIT 1 Current Outdoor Temperature Arrow icon indicates the direction the temperature is trending 2 Seasonal Information Wind chill will show when temperatures are below 40 F 4 C Dew Point when temperature is 41 79 F 5 26 C and Heat Index when temperature is over 80 F 27 C 3 Average Wind Speed Based on all wind speed readings from the past 2 minutes 4 Current Wind Speed 5 Learning Mode Icon Disappears after weather forecast self calibration is complete 6 12 to 24 Hour Weather Forecast Self Calibrating Forecasting pulls data from your sensor to generate your personal forecast 7 Humidity Level Indicator Indicates a high or low indoor humidity 21 level 8 Current Indoo
2. button When display is powered with the power adapter backlight remains on at 100 brightness Press Q button once to dim to 60 brightness press again to dim to 30 press a 3rd time to enter AUTO DIM mode AUTO DIM appears below time AUTO DIM MODE Automatically adjusts display brightness based on time of day amp year MARCH 11 NOVEMBER 4 6 00 a m 9 00 p m 100 brightness 9 01 p m 5 59 a m 30 brightness NOVEMBER 5 MARCH 10 7 30 a m 7 00 p m 100 brightness 7 01 p m 7 29 a m 30 brightness Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product mo Display Unit Placement ae Place the display unit in a dry area free of dirt and dust To ensure accurate temperature measurement place out of direct sunlight and away from heat sources or vents Display unit stands upright for tabletop use Jo 3 in 1 Sensor Placement The 3 in 1 sensor is designed to remain outdoors all year long 7 Choose an open location with no obstructions above or around the sensor for most accurate measurements Important Placement Guidelines Display unit and sensor must be within 330 feet 100 m of each other MAXIMIZE WIRELESS RANGE Place units away from large metallic items thick walls metal surfaces or other objects that m
3. expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty We recommend that you visit Us at of fitness for a particular purpose Chaney expressly disclaims www AcuRite com for the fastest way to register all liability for special consequential or incidental damages your roduct However product registration does whether arising in tort or by contract from any breach of this need toten Your or inal robl warranty Some states do not allow the exclusion or limitation BO j of incidental or consequential damages so the above limitation of purchase in order to obtain warranty benefits or exclusion may not apply to you Chaney further disclaims all liability from personal injury relating to its products to the extent Chaney Instrument Co warrants that all products it permitted by law By acceptance of any of Chaney s products manufactures to be of good material and workmanship and to be the purchaser assumes all liability for the consequences arising free of defects when properly installed and operated for a period from their use or misuse No person firm or corporation is of one year from the date of purchase Remedy for breach of authorized to assume for Chaney any other liability in connection this warranty is limited to repair or replacement of the defective with the sale of its products Furthermore no person firm or item s Any product which under normal use and SOV
4. ANC LJ gt 2 IT Instruction Manual Weather Center model 01604 A CONTENTS Unpacking Instructions 2 3 in 1 Sensor Installation 10 Package 2 Using the Weather Center 11 Product 2 13 Features amp Benefits 3 1 3 amp 15 Features amp Benefits Display AS 15 Pee ea 6 Intelli Time Battery 16 3 in Sensor 6 17 Display Unit 7 17 Set Time Date amp Units 8 Customer 5 18 Placement Guidelines Warnan ene 18 Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com SAVE THIS MANUAL FOR FUTURE REFERENCE ACUDIeITE Congratulations on your new AcuRite product To ensure the best possible product performance please read this manual in its entirety and retain it for future reference Unpacking Instructions Remove the protective film that is applied to the LCD screen prior fo using this product Locate the tab and peel off to remove Package Contents
5. ICE IS corporation is authorized to modify or waive the terms of this proven to breach the warranty contained herein within ONE YEAR paragraph and the preceding paragraph unless done in writing from date of sale will upon examination by Chaney and at its and signed by a duly authorized agent of Chaney This warranty sole option be repaired or replaced by Chaney Transportation gives you specific legal rights and you may also have other rights costs and charges for returned goods shall be paid for by which vary from state to state the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warranty will For in warranty claims not be breached and Chaney will give no credit for products Chaney Instrument Co 965 Wells St Lake Geneva WI 53147 AC 20 Weather Temperature Weather Kitchen Clocks Stations amp Humidity Alert Radio Thermometers amp Timers Its more than accurate It S ACUO RITE AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copyrights Printed in China are the property of their respective owners AcuRite uses patented technology 01604 INST 070314 Visit www AcuRite com patents f
6. ay limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electronic devices TV computer microwave radio etc LOCATE AWAY FROM HEAT SOURCES Position sensor away from heaters air conditioners chimneys exhaust vents asphalt and concrete surfaces that radiate heat LOCATE AWAY FROM HUMIDITY SOURCES Avoid installing the sensor near pools spas or other bodies of water Water sources may impact humidity accuracy LOCATE AWAY FROM SPRINKLER HEADS DO NOT install the sensor where it will be sprayed by a sprinkler system This may force water inside the sensor LOCATE AWAY FROM WIND OBSTRUCTIONS DO NOT mount the sensor with obstructions around it Consider a location that is a wide open area with few structures around to ensure accurate wind speed measurement Visit us online to view installation photos and video or learn more about AcuRite technology www dAcuRite com 3in1 View ve 3 in 1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at a minimum height of 5 feet 1 5 meters off the ground in an open area Higher is better for wind measurements the National Weather Service recommends 33 feet high MOUNTING OPTIONS The included mounting bracket is designed to screw directly onto wooden posts or surfaces that 2 x4 or larger The sensor can also be mounted directly to 3 4 steel or PVC pipe available at hardware Top Mount Sid
7. e Mount stores and home centers LEVEL INSTALLATION Use a bubble level not included to ensure level installation for accurate wind measurement Top or Side Mount 1 Insert the mounting base into the hole on the bottom of the sensor MOUNTING 2 Use one of the screws included in the hardware bag to fasten the lower sensor housing to the mounting base 3 Fasten mounting base to a post or railing using 2 screws Do not install during electrical storms Do not place pipe or sensor near electrical lines or Pipe Mount electrical equipment 1 Insert pipe or similar item all the way into the hole on the bottom of the sensor Note Mounting base is not used 2 Use one of the screws included in the hardware bag to fasten the lower sensor housing securely to the pipe The 3 in 1 sensor is now ready to use Basic Setup is Complete The 3 in 1 sensor will now synchronize with the display unit It may take a few minutes for synchronization to complete If both or one of the units appear to be functioning improperly please refer to the troubleshooting section OPERATION Using The Weather Center Learning Mode Self Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period called Learning Mode to determine your altitude After 14 days the Learning Mode icon disappears from the display screen At this point the self calibrated pressure is tuned in to you
8. ecords automatically clear at 12 00am midnight every day To manually clear all of today s LOW recorded values press and hold the button for 2 seconds Dashes display to confirm you have cleared the LOW records To manually clear all of today s HIGH recorded values press and hold the button for 2 seconds Dashes display to confirm you have cleared the HIGH records Press the 4 button to cycle through the all time high and low recorded values one record is shown at a time for outdoor and indoor temperature and humidity Located near the clock a date and time stamp are shown for when each value was recorded You will automatically exit all time records if no buttons are pressed for 5 seconds To manually clear all time LOW record press and hold the button for 2 seconds while viewing the record you wish to clear Dashes display to confirm you have cleared the record To manually clear an all time HIGH record press and hold the 4 button for 2 seconds while viewing the record you wish to clear Dashes display to confirm you have cleared the record 12 Troubleshooting Relocate the display unit and or the 3 in 1 sensor The units must be within 330 ft 100 m of each other Make sure both units are placed at least feet 9 away from electronics that may interfere with the wireless communication such as TVs microwaves computers etc Use standard alkaline batteries o
9. is device must accept any interference received including interference that may cause undesired operation of the device 17 Customer Support AcuRite customer support is committed to providing you with best in class service For assistance please have the model number of this product available and contact us in any of the following ways O 877 221 1252 info chaney inst com 24 7 support at www AcuURite com gt Installation Videos gt Register your Product gt Instruction Manuals gt Support User Forum gt Replacement Parts gt Submit Feedback amp Ideas IMPORTANT receve warranty service PRODUCT REGISTRATION n SUPRORT to receive year warranty protection i See 1 www AcuRite com Register a Product Limited One Year Warranty At AcuRite we proudly uphold our commitment it manufactures which have received normal wear and tear been damaged including by acts of nature tampered abused to quality technology Chaney Instrument Co improperly installed damaged In shipping or repaired or altered warrants that all products it manufactures to be of by others than authorized representatives of Chaney good material and workmanship and to be free of defects when properly installed and operated for a The above described warranty is expressly in lieu of all other warranties express or implied and all other warranties are period of one year from the date of purchase hereby
10. ix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals 7 Set the Time Date amp Units Press the button located on the front of the display unit to enter SET MODE Once in set mode the preference you are currently setting will blink on the display To adjust the currently selected flashing item press and release the or y buttons press and HOLD to fast adjust To save your adjustments press and release the 4 button again to adjust the next preference The preference set order is as follows TIME ZONE DST Daylight Savings Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR TEMPERATURE UNITS F or C PRESSURE UNITS inHg or hPa WIND UNITS MPH or KPH You will automatically exit SET MODE if no buttons are pressed for 10 seconds Enter setup mode at any time by pressing the button If you live in an area that observes Daylight Savings Time DST should be set to ON even if it is not currently Daylight Savings Time Display Backlight Settings This weather station s color display features three different lighting settings High 100 brightness Medium 60 brightness and Low 30 brightness Using battery power alone the backlight is available momentarily for 10 seconds by pressing the Y
11. ng Mode calibrates for a total of 33 days 13 Troubleshooting e Make sure both the display unit and 3 in 1 sensor are placed away from any heat sources or vents see page 9 e Make sure both units are positioned away from moisture sources see page 9 e Make sure 3 in 1 sensor is mounted at least 5 ft off of the ground Calibrate indoor and outdoor temperature and humidity see page 15 Inaccurate temperature or humidity e What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high or more Make sure to compare data using a sensor positioned at the ting height Inaccurate wind same mounting heig Check location of the sensor Ensure it s mounted readings minimum of 5 ft in the air with no obstructions around it within several feet eEnsure wind cups are spinning freely If they hesitate or stop try lubricating with graphite powder or spray lubricant Check that the batteries are installed correctly Batteries may need to be replaced e Reset the display by pressing the RESET button located on the back of the display unit in the battery compartment Date and time will need to be entered after a reset Display screen not working Inaccurate barometric It may take up to 14 days for the pressure to calibrate to y TOSS UP pressure your location The unit lost power or batteries were changed and the time is not correct The Intelli Time bat
12. nt NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and If not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two confitions 1 This device may not cause interference and 2 Th
13. or both the display unit and the sensor in order for the units to synchronize 1 Remove the battery compartment cover EE Plug in Power Adapter 2 Insert 3 x AAA alkaline batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover Plug in Power Adapter For the best performance plug in the power adapter as the main power source for this product A B C Switch set to match sensor Install Backup Batteries optional 3 AAA batteries O O IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage Power adapter is recommended as the ower source fo enjoy the full undionality of this produc PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT m
14. or details
15. r Temperature Arrow icon indicates the direction the temperature is trending 9 Today Icon 24 23 AN AMAW N gt Indicates viewing high low records since midnight 10 Moon Phase 11 All Time Icon Indicates viewing All Time records 12 3 Icon Indicates SET mode 13 Backlight Button 14 Intelli Time Clock Automatically updates itself for Daylight Saving Time 15 AUTO DIM Mode Indicator page 8 16 Display Low Battery Indicator 17 Date 18 Current Indoor Humidity Arrow icon indicates the direction the humidity is trending 19 Storm Indicator Indicates a rapid drop in pressure and probable storms 20 Barometric Pressure Arrow icon indicates the direction the pressure is trending Peak Wind Speed Highest speed from past 60 minutes 22 Current Outdoor Humidity Arrow icon indicates the direction the humidity is trending 23 Outdoor Sensor Signal Strength 24 Sensor Low Battery Indicator 4 Features amp Benefits BACK OF DISPLAY UNIT 2 3 4 amp Button for setup preferences i Button for setup preferences Button for setup preferences 44 Button Press to access all time high and low records 9 Battery Compartment Plug in for Power Adapter A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize Reset Button Full reset to factory defaults Power Adapter Battery Compartment Cover not shown 3 IN 1 Sensor Se
16. r lithium batteries in sensor when temperature is below 4 F 20 C Do not use No outdoor sensor heavy duty or rechargeable batteries NOTE It may take reception up to 20 minutes for display unit and sensor to synchronize after batteries are replaced no bars Synchronize the units 1 Bring both the sensor and display unit indoors and remove at least one battery from each Make sure the A B C switch on both units match Reinstall the battery in the outdoor sensor Reinstall battery into the display unit Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Flashing of the outdoor temperature may be an indication of Outdoor wireless interference Make sure the A B C switch in the battery compartments of both the display unit and sensor are switched to the same letter You may choose A B or C but both units must match to sync up Sometimes changing to a different channel can help temperature is flashing or showing dashes e Weather Forecast icon predicts conditions for the next 12 to 24 hours not current conditions e Has Learning Mode icon disappeared from the display unit Learning Mode must complete before forecast and Inaccurate forecast pressure will be accurate Allow unit to run continuously for 33 days Battery removal or resetting the display unit will restart Learning Mode After 14 days forecast should be fairly accurate however Learni
17. r location and the unit is ready for superior weather prediction Weather Forecast AcuRite s patented Self Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location RAIN SNOW SNOW LIGHT RAIN CLOUDY PARTLY MIX LIKELY LIKELY LIKELY CLOUDY windy DKN e rey 55 L444 Lightning Stormy View the complete list of icons at www AcuRite com acurite icons Subtle variations in barometric pressure greatly impact the weather This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING Track the phases of the moon conveyed through simple lunar phase icons N N N a V A Y p T A d i NEW WAXING 1ST FULL 3RD WANING CRESCENT QUARTER QUARTER CRESCENT Wind Speed The Wind Speed area of the display features the CURRENT speed as well as the AVERAGE and PEAK wind speeds AVERAGE wind speeds are based on all wind speed readings from the last 2 minutes PEAK wind speed is the highest speed recorded from the past 60 minutes High amp Low Records Today s high and low records are displayed for indoor and outdoor temperature humidity and wind speed Today s r
18. s a shelf life of several years To replace the Intelli Time battery 1 Locate the coin cell battery compartment door on the back of the display unit Unscrew and remove the compartment cover 2 Insert 1 x CR2032 coin cell battery into the battery compartment as shown Install battery with positive terminal facing OUT 3 Screw in the battery cover WARNING THIS PRODUCT CONTAINS A BUTTON CELL BATTERY IF SWALLOWED IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS SEEK MEDICAL ATTENTION IMMEDIATELY IF INGESTED 16 Specifications TEMPERATURE RANGE HUMIDITY RANGE WIND SPEED 99 9 _ 330 ft 100 m depending on home construction materials OPERATING FREQUENCY 433 mhz Display 5V 100mA power adapter 3 x AAA alkaline batteries Sensor 4 x AA alkaline or lithium batteries DATA REPORTING Wind Speed 18 second updates Outdoor temperature amp humidity 18 second updates Indoor temperature amp humidity 60 second updates FCC Information This device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to oper ate the equipme
19. tery needs to be replaced see page 16 Once the new battery is installed time and date will need to be set manually If your AcuRite product does not operate properly after trying the troubleshooting steps visit www AcuRite com or call 877 221 1252 for assistance 14 Care amp Maintenance Display Unit Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture Clean ventilation ports regularly with a gentle puff of air 3 in 1 Sensor Care Clean the Sensor Clean with a soft damp cloth Do not use caustic cleaners or abrasives Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 3 in 1 sensor To limit this problem spray sensor housing with a household insect repellent Note Insect repellent should not be sprayed on the internal components or into the sensor Consult insect repellent instructions prior to use Snow amp Freezing Weather The 3 in 1 sensor will not be damaged by freezing conditions Clean the Wind Anemometer Remove foreign matter from the outside of the sensor for free movement of the wind anemometer If needed use a small amount of spray lubricant clear silicone or graphite powder on the anemometer for improved movement Note Spray lubricant clear silicone or graphite powder should not be sprayed on the internal components or into the sensor Calibration The indoor outdoor temperature and humidit
20. tup Set the A B C Switch 1 The A B C switch is located inside the battery compartment It can be set to A B or C However you must 2 select the same letter choices for both the sensor and the display unit in order for the units to synchronize install or Replace Batteries 3 AcuRite recommends high quality alkaline or lithium batteries for the best product performance Heavy duty or rechargeable batteries are A not recommended The 3 in 1 sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the 3 in 1 sensor for temperatures below 4 F 20 C Press the release lever and pull off the lower housing of the sensor Remove the battery compartment cover Take note of the A B C switch setting inside the battery compartment Insert 4 x AA batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment Replace the battery cover and lower housing of the sensor A B C Switch NS set to match display unit 2 KA LITHIUM BATTERIES ALKALINE BATTERIES 6 40 F Install Batteries 4 AA batteries zoc 158 F 158 F Display Unit Setup Oo Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choices f
21. y readings and barometric pressure can be calibrated on the display unit to improve accuracy Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy 1 To access calibration mode press AND HOLD the 1 and buttons simultaneously for at least 5 seconds 2 To adjust the currently selected flashing item press and release the a or buttons to calibrate the data value higher or lower from the actual reading 3 To save your adjustments press and release the 4 button to adjust the next preference The gt lt icon will remain illuminated next to calibrated values The preference set order is as follows OUTDOOR TEMPERATURE OUTDOOR HUMIDITY INDOOR TEMPERATURE INDOOR HUMIDITY BAROMETRIC PRESSURE must be set to MANUAL mode to calibrate 15 change from AUTO to MANUAL pressure mode and vice versa press AND HOLD the 2 button for at least 10 seconds The display indicates the current pressure mode selected AUTO or MANUAL After 20 seconds of inactivity the display will save the adjustments and exit calibration mode Note Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged Replace Intelli Time Clock Battery Intelli Time technology is powered by a pre installed coin cell battery that stores the time and date settings The battery ha

Download Pdf Manuals

image

Related Search

Related Contents

USER MANUAL  USER'S GUIDE  Philips 816746 User's Manual  GBC ClickBind 15  T9 User Manual in English  Bedienungsanleitung  Bogen Loudspeaker AE-5 User's Manual  Minarc 150, 151 150 VRD 120 AU, 150 AU  VoiceOne - TC  

Copyright © All rights reserved.
Failed to retrieve file