1. BNC P105 lt J102 P104 SS e Qe eegqgeoeegegded e 1 pio TOTr 90Td Figure 2 4 VG4 A PSU1 or VG4 A PSU2 Power Supply Box Connected to Pipe Interface Board VG4 A PSU1 VG4 A PSU2 Pipe Interface Board 1 120 VAC 230 VAC Powerin 7 P101 Connector 2 P101 Connector 8 P107 Connector 3 Ground Connection 9 24 VAC Power In to AutoDome 4 Transformer 10 Earth Ground 5 24 VAC Power Out 11 24 VAC Power In to AutoDome 6 P107 Connector 12 24 VAC Power In to Heater 13 124 VAC Power In to Heater 14 AutoDome Power 15 Heater Power NOTICE Fiber Optic Models require that the Biphase control wires be routed from the Power Supply Box P106 connector out to the Pipe Interface Board P105 connector F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 15 2 4 2 Wiring the Power Supply Box 1 Route the high voltage 115 230 VAC lines through the conduit fitting on the left side of the box NOTICE The Power Supply Box with transformer comes with a barrier that separates the high voltag
2. NOTICE Fasteners are not supplied with the Roof Parapet Mount Kit since it depends on the material to which it is attached The material must accommodate a minimum pull out strength of 275 kg 600 Ibs For example 19 mm 3 4 inch minimum for plywood Fasteners can include bolts studs or lag bolts All fasteners must be made of corrosion resistant stainless steel with a diameter of 10 mm 3 8 inch All bolts must fully extend through the mounting surface and be secured with a flat washer lock washer and a nut All studs must be anchored to concrete or welded to a steel backing plate Anchor bolts can be used for blind structures where there is no access to the rear 3 Apply a weatherproof sealant around each fastener hole at the mounting surface 4 Attach the Parapet Wall Bracket using at least six 6 stainless steel fasteners three 3 on each side the bracket has eight 8 holes Be careful not to over tighten the fasteners because it may strip the threads If attaching the parapet mount to a flat roof attach the optional LTC 9230 01 Roof Mount Plate to the roof and then attach the Parapet Wall Bracket to the Roof Mount Plate 5 Insert the Parapet Pipe Arm into the mounting bracket until it bottoms in the bracket F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 19
3. 24 V to AutoDome VA Watts 14 AWG 2 5 mm 16 AWG 1 5 mm 18 AWG 1 0 mm AutoDome 100 Indoor 14 7 5 248 m 813 ft 156 m 512 ft 98 m 322 ft AutoDome 100 Outdoor 47 43 5 74 m 242 ft 46 m 152 ft 29 m 96 ft AutoDome 600 Indoor 27 15 129 m 422 ft 81m 265 ft 51 m 167 ft AutoDome 600 Outdoor 55 51 63 m 207 ft 40 m 130 ft 25 m 82 ft AutoDome 700 Indoor 35 19 99 m 325 ft 62 m 205 ft 39 m 129 ft AutoDome 700 Outdoor 60 55 58 m 190 ft 36 m 119 ft 23 m 75 ft 1 Standard heater module Add Add 16 W if using VG4 SHTR XT kit 2 Standard heater module The VG4 SHTR XT kit is not applicable to VG5 700 Series AutoDomes Video and Control Cables Using Coaxial Cable to Transmit Video and Control CAUTION 600 Series AutoDome If you are using coaxial cable to transmit video and data between the AutoDome and the head end you must use the coax cable with ferrite included in the AutoDome packaging You must connect the incoming coax cable from the head end to the jack female end on the ferrite cable and connect the plug end male connector of the ferrite cable to the AutoDome s coax connector Coaxial cable terminated with BNC connectors is the most common method for transmitting composite video Bilinx control data can also be sent over the same cable Bilinx is a Bosch 2 way communication protocol that allows remote control configuration and updates over a vide
4. Data Interface Ethernet Data Rate 10 100 Mbps IEEE 802 3 Compliant Full Duplex or Half Duplex Electrical Port Full Duplex Optical Port Fiber Type MMF 50 125 um MMF For 50 125 um fiber subtract 4 dB from the specified optical budget value Must meet or exceed fiber standard ITU T G 651 Fiber Type SMF 8 10 125 um SMF Must meet or exceed fiber standard ITU T G 652 Maximum Distance 60 km 37 3 miles Requirement Media converter receiver CNFE2MC IN at controller end of system Terminal Connection Duplex LC or Single SC Control only Cables Controlling the AutoDome via Biphase Shielded 2 wire half duplex multi drop 5000 ft cable limit Biphase is the standard Bosch protocol used to send Pan Tilt Zoom control over 2 wire shielded twisted pair STP terminated with a 100 O terminal resistor The AutoDome has a 100 Q termination resistor between the Biphase C and C terminals CAUTION The Biphase shield must be connected to the head end only Cable Type STP Shielded Twisted Pair Distance 1524 m 5000 ft Belden 8760 recommended Transmission Rate 31 25 KHz Gage 1 02 mm 18 AWG Termination 100 Q Terminal Connector Screw terminals Voltage 4 Vp p Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 30 en Cable and Wire Standards AutoDome Roof Parapet Mount The figure below illustrates the connections necessary for Biphas
5. AutoDome Roof Parapet Mount Alarms and Relay Connections en 37 4 Alarms and Relay Connections 4 1 Alarm Inputs The AutoDome provides seven alarm inputs Each input can be activated by dry contact devices such as pressure pads passive infrared detectors door contacts and similar devices The table below summarizes the size and distance wires Wire Size Maximum Distance AWG mm feet meters 22 0 644 500 152 4 18 1 024 800 243 8 Table 4 1 Alarm wire guide You wire alarms either Normally Open N O or Normally Closed N C and must program the alarm inputs N O the default or N C through the AutoDome main menu The AutoDome incorporates two 2 types of alarms Non supervised and Supervised In addition to transmitting an alarm condition a supervised alarm also transmits a tamper condition Depending on how the alarm is configured a short or a break in the alarm s circuit can trigger the tamper signal 4 2 Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through the AutoDome main menu to either Normally Open Supervised N O S or Normally Closed Supervised N C S NOTICE Only Alarms 1 and 2 pins 5 or 6 can be configured for supervision Once a supervised alarm is programmed it does not need to be enabled to indicate a tamper condition 4 2 1 Co
6. 6 Remove the End Cap from the front of the arm and feed the video control and power wires up through the bottom of the pipe arm and out the front end er Figure 2 7 Parapet Mount 1 End Cap with O ring 2 Parapet Pipe Arm 3 1 4 20 SS Cap Screw 4 Down Pipe 5 10 24 SS Pan Head Screw 7 Fold the video control and power wires back at the front end of the arm and route them down and out through the Down Pipe Then replace the End Cap 8 Wrap at least five layers of Teflon tape around the Down Pipe threads 9 Apply the supplied thread sealant to the Down Pipe threads Make sure all surfaces are clean and dry Apply a bead of sealant completely around the leading threads of the male fitting Force the adhesive into the threads to thoroughly fill all voids 10 Thread the Dome Cap onto the down pipe and tighten securely See the illustration below WARNING You must thread the Dome Cap onto the Down Pipe until it is tight Failure to do so can result in damage serious injury or death Figure 2 8 Attach Dome Cap 1 Thread Sealant or tape 2 Dome Cap Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 20 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 11 Runa bead of RTV Silicon sealant around the down pipe Dome Cap interface to seal any gaps between the down pipe and the Dome Cap 12 Proceed to Section 2 6 Wire the Pipe Interface Boa
7. Fiber Optic kits available for AutoDome 100 and 600 Series cameras transmit both video and Biphase control over an analog singlemode or multimode fiber Multimode Fiber Type 50 125 um 62 5 125 um low loss multimode glass fiber Maximum Distance 4 km 2 5 miles Minimum Bandwidth 20 MHz Video 850 nm Control 1300 nm Requirement Bosch LTC 4629 Fiber Receiver at controller end of system Terminal Connector ST Singlemode Fiber Type 9 125 um low loss single glass fiber Maximum Distance 69 km 43 miles Minimum Bandwidth 20 MHz Video 1310 nm Control 1550 nm Requirement Single mode fiber receiver at controller end of system Terminal Connector ST F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Cable and Wire Standards en 29 3 3 5 3 4 3 4 1 Using a Fiber Optic Ethernet Media Converter to Transmit Video and Control The fiber optic media converter kit available for AutoDome 700 Series cameras is designed to transmit 10 100 Mbps Ethernet signals over fiber optic cable using 10 100 Mbps Small Form factor Pluggable SFP modules The SFP modules are available as multi mode fiber MMF or single mode fiber SMF models with a single SC connector or dual fiber with an LC connector Refer to the VG4 SFPSCKT Fiber Optic Media Converter Installation Guide Ethernet Media Converter
8. If not avoided this will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low risk Indicates a potentially hazardous situation If not avoided this could result in property damage or risk of damage to the unit OBB D NOTICE This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property 1 2 Important safety instructions Read follow and retain for future reference all of the following safety instructions Heed all warnings on the unit and in the operating instructions before operating the unit 1 Cleaning Unplug the unit from the outlet before cleaning Follow any instructions provided with the unit Generally using a dry cloth for cleaning is sufficient but a moist fluff free cloth or leather shammy may also be used Do not use liquid cleaners or aerosol cleaners 2 Water Do not use this unit near water for example near a bathtub washbow l sink laundry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as a wet location To reduce the risk of fire or electrical shock do not expose this unit to rain or moisture 3 Object and liquid entry Never push objects of any kind into this unit through openin
9. This chapter details how to install an AutoDome roof parapet mount Any variations to the installation procedures are noted Note You may need to purchase additional mounting accessories for roof mount applications Refer to Section 2 1 2 Optional Mounting Accessories page 9 The VGA ROOF MOUNT mounts are stationary mounts intended for rooftop parapet vertical walls They are made of light weight aluminum with a corrosion resistant finish and are used for all Bosch AutoDome Cameras up to a rated load of 29 kg 64 Ib These mounts can be fitted to the inside or outside of parapet walls and can swivel for ease of positioning and for servicing the AutoDome Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 10 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 1 5 2 2 Tools Required 5mm Allen wrench supplied Small straight blade screwdrivers 2 5 mm 0 1 in 3 1 mm 1 8 in Medium straight blade screwdriver No 1 and No 2 Phillips screwdrivers Socket wrench and 9 16 in socket Pipe Wrench Barrel connector if installing a fiber optic model Pre installation Check List 1 Determine the location and distance for the power supply box based on its voltage and current consumption Refer to Section 3 Cable and Wire Standards page 26 for wiring information and distances 2 Use only UL listed liquid tight strain reliefs for conduits to the Power S
10. THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Bosch notices Video loss Video loss is inherent to digital video recording therefore Bosch Security Systems cannot be held liable for any damage that results from missing video information To minimize the risk of lost digital information Bosch Security Systems recommends multiple redundant recording systems and a procedure to back up all analog and digital information Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly Note This manual has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between the user guide and the product described More information For more information please contact the nearest Bosch Security Systems location or visit www boschsecurity com F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount I
11. supply only 1 Analog AutoDome Attach a BNC connector to the video coax cable and connect it to its mating connector J102 on the Pipe Interface Board 2 Analog AutoDome If using UTP for video attach an RJ45 connector plug to the UTP cable and connect the plug to its mating connector J101 on the Pipe Interface Board WARNING Do not connect the RJ45 connector unless using UTP video This connection causes video distortion 3 IP AutoDome Attach an RJ45 connector plug to the Ethernet cable and connect the plug to its mating connector J101 on the Pipe Interface Board WARNING Do not connect the RJ45 connector unless using UTP video or Ethernet This connection causes video distortion 4 Attach the control data in out wires to their respective terminals on the P105 connector on the Pipe Interface Board Refer to Figure 2 9 Page 20 for an illustration of these connections 5 Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board If this model has a heater connect the 24 VAC heater power wires to connector P107 CAUTION To protect the AutoDome from damage due to cold temperatures ensure that you connect the gt Bb Bb D 24 VAC heater power wires to the P101 connector 6 To connect alarm inputs and outputs attach the supplied 6 pin Alarms In and the 4 pin Alarms Out connector plugs with flying leads to the appropriate alarm wires Then connect the plugs to their mating
12. AutoDome Roof Parapet Mount VGA ROOF MOUNT BOSCH en Installation Guide AutoDome Roof Parapet Mount Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 1 1 Safety precautions 5 1 2 Important safety instructions 5 1 3 Important Notices 7 1 4 UL certification 7 1 5 Bosch notices 8 2 Installing the Roof Parapet Mount 9 2 1 Unpacking 9 2 1 1 Parts List 9 2 1 2 Optional Mounting Accessories 9 24 3 Optional Power Supplies 9 2 1 4 Description 9 2 15 Tools Required 10 2 2 Pre installation Check List 10 2 3 Mount Power Supply Box 11 2 3 1 Attach Cover Door 12 2 4 Route Wires and Attach Connectors 13 2 4 1 Methods for Routing Wires 13 2 4 2 Wiring the Power Supply Box 15 2 4 3 Power Supply Box Connections 16 2 5 Installing the Roof Parapet Mount 17 2 6 Wire the Pipe Interface Board 20 2 6 1 Wiring for Multiple AutoDomes 21 2 6 2 Connecting Wires to the Pipe Interface Board 22 2 7 Attach Pendant to Pipe and Tighten 24 3 Cable and Wire Standards 26 3 1 Power 26 3 2 Wire Distance Guide for Pendant 26 3 3 Video and Control Cables 26 3 3 1 Using Coaxial Cable to Transmit Video and Control 26 3 3 2 Using UTP to Transmit Video and Control 27 3 3 3 Using Ethernet to Transmit Video and Control 28 3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control 28 3 3 5 Using a Fiber Optic Ethernet Media Converter to Transmit Video and Control 29 3 4 Control only Cables 29 3 4 1 Controlling the AutoDome
13. Closed Normal Short Tamper F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Alarms and Relay Connections en 39 4 3 Configuring Non supervised Alarms inputs 1 through 7 You can configure alarms 3 through 7 as non supervised Normally Open N O or Normally Closed N C alarms 4 3 1 Configuring a Normally Open Non supervised Alarm 1 Connect the alarm to the appropriate input 1 through 7 and ground at the AutoDome Figure 4 3 N O Normally Open Non supervised Connections 1 Dry Contact 3 Dome Connector 2 Alarm Inputs 1 to 7 4 Ground 2 From the AutoDome main menu select Alarm Setup gt Inputs Setup and set Alarm Input to N O See the table below for contact and condition details AutoDome Programmed N O Circuit Alarm Indication Open Normal Closed Alarm 4 3 2 Configuring a Normally Closed Non supervised Alarm 1 Connect the alarm to the appropriate input 1 through 7 and ground at the AutoDome Figure 4 4 N C Normally Closed Non supervised Connections 1 Dry Contact 3 Dome Connector 2 Alarm Inputs ito7 4 Ground 2 From the AutoDome main menu select Alarm Setup gt Inputs Setup and set Alarm Input to N C See the table below for contact and condition details AutoDome Programmed N C Circuit Alarm Indication Open Alarm Closed Norm
14. Line Input Specifications Max Input Voltage 5 5 Vpp Impedance 9KO Sample Rate 8 K Hz 16 Bit mono Shield Bare copper braid 95 coverage Internal gain level adjustment is available Wire Specifications Wire Type Coax recommended Distance 10 m 33 ft Gage 22 AWG to Biphase connector P105 P106 Shield Bare copper braid 95 coverage Center conductor Stranded bare copper NOTICE Separate the audio cables from the AC power lines to avoid noise Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 36 en Cable and Wire Standards AutoDome Roof Parapet Mount Audio Connections 1 Remove the 100 Q termination resistor from the Biphase terminals 2 Connect the audio line level source to the Biphase C input terminal 3 Connect the audio signal ground to the Biphase C input terminal The following figure illustrates the connections for audio over an IP network Figure 3 10 Connections for audio over an Ethernet network 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 P105 P106 Connector 3 Earth Ground 9 Audio Out 4 RxD 5 TxD 6 Signal Ground NOTICE Refer to the VG5 700 Series AutoDome User Manual for configuring and using audio over an IP Ethernet network F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc
15. P107 24 VAC Power to Dome Dome Earth Heater Heater Dome Plug 24 VAC 24 VAC Ground 24 VAC 24 VAC 1 Applicable to VG5 600 and 100 Series AutoDomes only Table 2 1 Power Box Connections 2 5 Installing the Roof Parapet Mount This section details the installation steps for the Roof Parapet Mount Figure 2 5 Parapet Roof Mount 1 Determine the wall location on the roof for the AutoDome and use the Parapet wall mount bracket as a template to mark the hole locations NOTICE Allow enough room below the Parapet Mount Bracket to route the video control and alarm wires up through the Parapet arm In certain installations you may have to lift the Parapet arm for the AutoDome to clear the top of the wall when it is swung into position Provide enough slack in the wires to rotate the pipe arm over the roof and back when camera maintenance is required Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 18 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 Prepare the mounting surface for the type of fastener by drilling holes for the mounting anchors as required Figure 2 6 Parapet Wall Mount Bracket and Roof Mount Plate 1 Pipearm 4 Apply sealant around each fastener hole Parapet Wall Bracket 5 Roof Mount Plate 3 3 8 16 SS Hex Head Bolt supplied 6 Use a minimum of six 6 fasteners not supplied Eight 8 fastener holes shown N
16. al Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 40 en Alarms and Relay Connections AutoDome Roof Parapet Mount 4 4 Alarm Outputs The AutoDome incorporates two 2 types of alarm outputs a dry contact relay and three 3 open collector outputs or transistor outputs 4 4 1 Configuring a Dry Contact Relay The dry contact relay acts like an on off switch It has a maximum voltage rating of 2A 30 DC 1 Connect the appropriate stripped wire to the AutoDome COM connector 2 Connect the appropriate stripped wire to the N O or N C connector depending on your requirement 4 4 2 Configuring an Open Collector Output Outputs 1 2 and 3 are open collector types These outputs must be connected to a positive voltage between 5 and 32 V to complete the circuit with a maximum voltage rating of 32 VDC 150 ma 1 Connect the appropriate stripped wire to the open connector 1 2 or 3 of the transistor 2 Connect the appropriate stripped wire to the ground GND connector F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc Bosch Security Systems Inc 850 Greenfield Road Lancaster PA 17601 U S A www boschsecurity com Bosch Security Systems Inc 2011
17. al use an isolation transformer available separately from Bosch CAUTION Connecting System ground to Safety ground may result in ground loops that can disrupt the CCTV system 1 4 UL certification Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualty hazards as outlined in UL s Standard s for Safety for Closed Circuit Television Equipment UL 2044 UL Certification does not cover the performance or reliability of the security or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 8 en Important Safety Instructions AutoDome Roof Parapet Mount 1 5 Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualty hazards as outlined in UL s Standard s for Safety for Information Technology Equipment UL 60950 1 UL Certification does not cover the performance or reliability of the security or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING
18. ay Output P104 AWG 26 16 3 Normally Closed 2 Common 1 Normally Open 9 Dome Power P101 AWG 18 14 3 Dome 24 VAC 2 Earth Ground 1 Dome 24 VAC 10 Heater Power P107 AWG 18 14 2 Heater 24 VAC 1 Heater 24 VAC 11 RJ45 Ethernet or UTP Video J101 Ethernet for VG5 700 Series only 12 To AutoDome 2 6 1 Wiring for Multiple AutoDomes To wire multiple AutoDomes in a series or daisy chaining you must apply a terminating resistor to the last dome of the series The Interface Board is supplied with a 100 Q terminating resistor located between the Biphase terminals C and C pins 1 and 2 of the P105 control connector see item 5 in Figure 2 9 above Remove the resistor from all but the last AutoDome Interface Board The maximum number of AutoDomes that can be daisy chained is four 4 If using the RS485 protocol for control switch the terminating resistor from the Biphase C and C terminals to the RxD and TxD terminals pins 4 and 5 of the P105 control connector for the last dome refer to item 6 in Figure 2 9 above Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 22 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 6 2 Connecting Wires to the Pipe Interface Board The Pipe Interface Board contains all of the connectors for control data image and power wires Follow the procedures below to make the proper connections WARNING Use a 24 VAC Class 2 power
19. box Then release the bottom hinge pin from the Hinge Pin Stop to complete attaching the Cover Door to the Power Supply Box NOTICE After all wiring is complete close the cover door and tighten the two 2 captive screws on the cover door to 10 12 N m 90 105 in lbs to ensure the Power Supply Box is watertight F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 13 2 4 Route Wires and Attach Connectors NOTICE AutoDome power supply boxes are sold separately Skip the following section if your application does not utilize one of these power supplies VG4 A PSUO VG4 A PSU1 or VG4 A PSU2 Power wires must be routed to the left front side of the Power Supply Box through a separate conduit All video control and alarm wires must be routed through a second conduit to the right side of the box Refer to Section 3 Cable and Wire Standards page 26 for methods of transmitting video and data and for wire specifications WARNING External interconnecting cables are to be installed in accordance to NEC ANSI NFPA7O for US application and Canadian Electrical Code Part CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation A readily ac
20. cessible 2 pole disconnect device with a contact separation of at least 3 mm must be incorporated 2 4 1 Methods for Routing Wires There are two possible methods to route the video control and alarm wires One is to route the video control and alarm wires through the conduit fitting on the right front side of the Power Supply Box and out to the AutoDome Interface Board XF103 H 54321 Figure 2 3 VG4 A PSU1 or VG4 A PSU2 Power Supply Box 1 120 VAC 230 VAC Power In 5 Coax UTP Video or Ethernet Wire Ethernet for VG5 700 Series only 2 P101 Connector 6 Control Wire 3 Ground Connection 7 24 VAC Power Out 4 Transformer 8 P107 Connector Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 14 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount The second method is to bypass the Power Supply Box and route the video control and alarm wires directly to the Interface Board You connect only the power wires inside the Power Supply Box XF101 XF103 H 54321
21. connectors P103 and P102 on the Pipe Interface Board e PIN NOOO BP WNPE 2 9 o z H gt a gt iS 2 z s OAoORWNHE Figure 2 10 Alarm and Relay Connector Plugs F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 23 1 4 pin Alarm Connector 2 6 pin Alarm In Connector 3 7 pin Relay Connector P102 P103 P104 Pin Description Pin Description Pin Description 1 Alarm Out 1 1 jAlarm In 3 1 Alarm Out 4 Normally Open 2 Alarm Out 2 2 Alarm In4 2 Alarm Out 4 COM 3 Alarm Out 3 3 Alarm In 5 3 Alarm Out 4 Normally Closed 4 Alarm Ground 4 Alarm In 6 4 Earth Ground 5 Alarm In 7 5 Analog Alarm 1 6 Alarm Ground 6 Analog Alarm 2 7 Ground 7 To connect supervised alarms and relays attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board see Figure 2 10 above In addition refer to Section 4 Alarms and Relay Connections page 37 for more details on wiring alarms and relays Note There is a slot located at the top of the Interface Board to tie the wires to the circuit board with a cable tie 8 Insert the Pipe Interface Board into the down pipe and fasten the three 3 retaining screws to secure the board to the Dome Cap CAUTION Be careful not to s
22. e side on the left from the low voltage 24 VAC side on the right 2 Cut and trim the high voltage 115 230 VAC power and ground wires with sufficient slack to reach their connector terminal in the box but not so long as to be pinched by or to obstruct closing the Cover Door 3 Attach the supplied 3 pin Power Plug to the incoming high voltage power wires in the box Refer to connector P101 in Table 2 1 Page 17 4 Analog AutoDome If you are using UTP for video route the UTP cable out to where the AutoDome will be mounted Refer to Section 3 Cable and Wire Standards page 26 for fiber optic specifications 5 IP AutoDome Route the Ethernet cable out to where the AutoDome will be mounted Refer to Section 3 Cable and Wire Standards page 26 for specifications 6 Route the low power 24 VAC wires from the right side of the Power Supply Box out to where the AutoDome will be mounted Attach the supplied 5 pin 24 VAC Dome plug to the wire ends inside the box Refer to connector P107 in Table 2 1 Page 17 NOTICE All video control and alarm wires either pass through the Power Supply Box or by pass it and connect directly to the Pipe Interface Board Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 16 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 4 3 Power Supply Box Connections The following figure is a detailed illustration of the Roof or Pipe Mount Power Supp
23. e operation Figure 3 2 Connections for Biphase Operation 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 Head End Biphase 3 Earth Ground 9 P105 P106 Connector 4 RxD 10 C Biphase 5 TxD 11 C Biphase 6 Signal Ground 12 Shield In a daisy chain configuration where multiple domes are connected in series the 100 Q resistor must be removed from all but the last dome You can daisy chain a maximum of four 4 AutoDomes Figure 3 3 Connections for a Daisy Chain Configuration 1 C Biphase 9 Dome 3 2 C Biphase 10 Dome 2 3 Earth Ground 11 Dome 1 4 RxD 12 Head End Biphase 5 TxD 13 C Biphase 6 Signal Ground 14 C Biphase 7 Last Dome Data In Out 15 Shield 8 P105 P106 Connector OOO F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Cable and Wire Standards en 31 3 4 2 Controlling the AutoDome via the RS232 Protocol 3 wire full duplex single ended 50 ft cable limit RS232 is acommon single ended communication protocol used for control Data transmission via 3 wires TDX RXD common is from one transmitter to one receiver at relatively slow baud rates up to 57 6 Kbaud and short distances up to 50 ft NOTICE After making the wire connections for RS232 operation reposition the slide switch located on the CPU Mod
24. feature cable compensation or Pre Comp which extends the normal range of control from the head end WARNING Do not connect the RJ45 connector unless using UTP video Cable Compensation Maximum Distance Cable Type Pre comp OFF Pre comp ON CAT5 UTP 229 m 750 ft 450 m 1500 ft Terminal Connector RJ45 Requirement Coax to UTP Converter The following figure illustrates the connections necessary to transmit video and control over a UTP cable 1 amp 2 Figure 3 1 Video and Control over UTP 1 Head End Video 3 Pins 2 Coax 4 AutoDome Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 28 en Cable and Wire Standards AutoDome Roof Parapet Mount 3 3 3 Using Ethernet to Transmit Video and Control CAUTION Ethernet connections must be made to non exposed indoor networks only The AutoDome VG5 700 series connects to a 10 Base T 100 Base TX network either directly or via a switch Both video and control are transmitted over a standard TCP IP network using the built in Web server Cable Type CAT 5E or CAT 6 Ethernet Maximum Distance 100 m 328 ft Bandwidth 10 Base T 100 Base TX Terminal Connector RJ45 Female WARNING Do not connect a coaxial cable while the RJ45 Ethernet cable is connected 3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control
25. gs as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 4 Power cord and plug protection Protect the plug and power cord from foot traffic being pinched by items placed upon or against them at electrical outlets and its exit from the unit For units intended to operate with 230 VAC 50 Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 5 Power disconnect Units have power supplied to the unit whenever the power cord is inserted into the power source The power cord plug is the main power disconnect device for switching off the voltage for all units Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 6 en Important Safety Instructions AutoDome Roof Parapet Mount 10 11 12 Power sources Operate the unit only from the type of power source indicated on the label Before proceeding be sure to disconnect the power from the cable to be installed into the unit For battery powered units refer to the operating instructions For external power supplied units use only the recommended or approved power supplies For limited power source units this power source must comply with EN60950 Substitutions may damage the unit or cause fire or shoc
26. ion of service or repairs to the unit to ensure proper operating condition Installation Install in accordance with the manufacturer s instructions and in accordance with applicable local codes Attachments changes or modifications Only use attachments accessories specified by the manufacturer Any change or modification of the equipment not expressly approved by Bosch could void the warranty or in the case of an authorization agreement authority to operate the equipment F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Important Safety Instructions en 7 1 3 Important Notices U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode Disposal Your Bosch product was developed and manufactured with high quality material and components that can be recycled and reused This symbol means that electronic and electrical appliances which have reached the end of their working life must be collected and disposed of separately from household waste material Separate collecting systems are usually in place for disused electronic and electrical products Please dispose of the
27. k For 24 VAC units voltage applied to the unit s power input should not exceed 10 or 28 VAC User supplied wiring must comply with local electrical codes Class 2 power levels Do not ground the supply at the terminals or at the unit s power supply terminals If unsure of the type of power supply to use contact your dealer or local power company Servicing Do not attempt to service this unit yourself Opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage requiring service Unplug the unit from the main AC power source and refer servicing to qualified service personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user correctly follows the operating instructions Replacement parts Be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substitutions may cause fire electrical shock or other hazards Safety check Safety checks should be performed upon complet
28. ly Box which includes the fuse specifications G 2 se o los o Fels Ho s a 0 N 23 op o o 1 Ground Screw 5 Power In 2 Transformer 115 230 VAC Modes 6 In Out 1 2 in 15 mm NPS Fitting 3 In Out to Dome 7 Power In 3 4 in 20 mm NPS Fitting 4 24 VAC to Dome Interface Board 8 Control Data and Video In Out 3 4 in 20 mm NPS Fitting WARNING Fuse replacement by qualified service personnel only Replace with same type fuse Fuse Specifications Volts XF101 Mains XF102 Camera XF103 Heater 24 V T5 0A T2 0A T3 15A 115V T1 6A T2 0A T3 15A 230 V T 0 8A T2 0A T3 15A F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 17 The following table lists the Power Supply Box connectors No Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin5 Pin6 Ground Grounding Screw P101 115 230 VAC or 24 Line NC Neutral VAC Power In P105 Control to Dome C C Earth RXD TXD Signal Fiber Optic Biphase Biphase Ground RS 232 485 RS 232 485 Ground Model P106 Control In Out C C Earth RXD TXD Signal Optional Biphase Biphase Ground RS 232 485 RS 232 485 Ground
29. n the location of the AutoDome and the application CAUTION Select a rigid mounting location to prevent excessive vibration to the AutoDome camera F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 11 2 3 Mount Power Supply Box NOTICE AutoDome power supply boxes are sold separately Skip the following section if your application does not utilize one of these power supplies VG4 A PSUO VG4 A PSU1 or VG4 A PSU2 Before mounting the Power Supply Box decide if you will be wiring the box through the holes in the bottom or back of the box If wiring the box through the back move the two 2 seal plugs to the bottom holes before mounting Refer to Section 2 1 3 Optional Power Supplies page 9 for a list of compatible power supply boxes NOTICE Use 3 4 inch NPS 20 mm fittings for the holes on the bottom and back of the box Use 1 2 inch NPS 15 mm fittings for the side holes Figure 2 1 Wall Mount Power Supply with Optional Trim Skirt 1 Use the wall mount template supplied in the packaging box to locate the four 4 mounting holes for the Power Supply Box 2 Drill four 4 holes for the mounting anchors If installing outdoors apply a weatherproof sealant around each hole at the mounting surface 3 Place the Power Supply Box into the optional Trim Skirt 4 Secure the Power Supply Box to the wall u
30. nd on the green RxD wire enough to be able to connect these wires back into the P106 connector 6 Connect the blue ground wire to the C pin on the P106 connector 7 Connect the green RxD wire to the C pin on the P106 connector E J ab gt 24VAC SEAN la b LL 00 eh x ii N op 10 2101 paR ED 8 24V HAE 24 O ED d RF O Figure 3 8 Detail of P106 Connections 1 Green RxD wire connected to C 2 Blue Ground wire connected to C 8 Connect the fiber optic cable from the AutoDome to the LTC 4629 9 Close the door to the power supply unit F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Cable and Wire Standards en 35 10 Ensure that the VG5 AutoDome is set to receive RS232 commands Remove the bubble from the VG5 AutoDome housing Locate the protocol switch on the CPU board Ensure that the protocol switch is in the left position for RS232 operation Figure 3 9 Position of CPU Switch for RS232 Operation Switch Location LEDs Move Switch to the left for RS232 Operation BA OO N e CPU Module 11 Return the bubble to the AutoDome housing 12 Return power to the power supply box 3 6 Audio Cables The VG5 700 Series AutoDome is capable of receiving line input audio signals and transmitting it over a network The audio signal is transmitted one way and in sync with the video signals Audio
31. nfiguring a Normally Open Supervised Alarm 1 Install a 2 2 K end of line resistor in the alarm circuit 2 Connect the alarm wires to input 1 or 2 pin 5 or 6 and to the ground pin 7 at the AutoDome Figure 4 1 N O S Normally Open Supervised Connections 1 Dry Contact 3 Dome Connector 2 Alarm 1 or 2 only PinS5or6 4 Ground Pin 7 Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 38 en Alarms and Relay Connections AutoDome Roof Parapet Mount 3 From the AutoDome main menu select Alarms Setup gt Inputs Setup and set the Alarm Input to N O S See the table below for contact and condition details AutoDome Programmed N O S Contact Alarm Condition Open Normal Closed Alarm Cut or brake Tamper 4 2 2 Configuring a Normally Closed Supervised Alarm 1 Install a 2 2 K end of line resistor in the alarm circuit 2 Connect the alarm wires to input 1 or 2 pin 5 or 6 and to the ground pin 7 at the AutoDome Figure 4 2 N C S Normally Closed Supervised Connections 1 Dry Contact 3 Dome Connector 2 Alarm 1 or 2 only Pin 5 or 6 4 Ground Pin 7 3 From the AutoDome main menu select Alarm Setup gt Inputs Setup and set Alarm Input to N C S See the table below for contact and condition details AutoDome Programmed N C S Contact Alarm Condition Open Alarm
32. nstalling the Roof Parapet Mount en 9 2 2 1 2 1 1 2 1 2 2 1 3 2 1 4 Installing the Roof Parapet Mount Unpacking This equipment should be unpacked and handled with care If an item appears to have been damaged in shipment notify the shipper immediately Verify that all the parts listed in the product s Parts List below are included If any items are missing notify your Bosch Security Systems Sales or Customer Service Representative The original packing carton is the safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use Parts List The following table lists the parts included with this mounting package Part Numbers Parapet Roof Mount VGA ROOF MOUNT Optional Mounting Accessories The following table lists the optional parts you may need for attaching a Pendant Arm to a roof parapet mount Mounting Options Part Numbers Flat Roof Mount Adapter LTC 9230 01 Plpe Mount VG4 A 9543 Optional Power Supplies The roof parapet mounts do not come with an attached power supply The following table lists the optional power supplies that are compatible with VG5 Series AutoDomes Mounting Options Part Numbers 24 VAC no transformer NEMA rated with cover VG4 A PSUO 120 VAC transformer NEMA rated with cover VG4 A PSU1 230 VAC transformer NEMA rated with cover VG4 A PSU2 Description
33. o coax cable Bilinx is available on all VG5 100 and 600 Series AutoDomes VG5 Series AutoDomes feature cable compensation or Pre Comp which extends the range of video from the head end F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Cable and Wire Standards en 27 Cable Compensation Maximum Distances Video Only Bilinx Control Cable Type Pre comp OFF Pre comp ON Pre comp ON or OFF RG 59 U 300 m 1000 ft 600 m 2000 ft 300 m 1000 ft RG 6 U 450 m 1500 ft 900 m 3000 ft 450 m 1500 ft RG 11 U 600 m 2000 ft 1200 m 4000 ft 600 m 2000 ft Size O D between 4 6 mm 0 181 in and 7 9 mm 0 312 in Shield Copper braid 95 Central Conductor Standard copper center Terminal Connector BNC WARNING Cable compensation Pre Comp does not extend the range of Bilinx control Pre Comp is not available with VG5 700 Series AutoDomes 3 3 2 Using UTP to Transmit Video and Control Unshielded twisted pair UTP cable terminated with RJ45 male connectors are used to transmit composite video using pins 1 and 2 Typically a Coax to UTP cable converter is required at the head end of the system Bilinx control data can also be sent over the same two video wires 1 amp 2 Bilinx is a Bosch 2 way communication protocol that allows remote control configuration and updates over a passive UTP cable VG5 Series AutoDomes
34. rd page 20 NOTICE Use a guy wire to aid in stabilizing the Parapet Arm Replace the 1 4 inch cap screw with a threaded 1 4 inch stainless steel eye bolt not supplied Loop the guy wire through the eye bolt and attach both ends to anchor spots on the roof Refer to Figure 2 7 Page 19 2 6 Wire the Pipe Interface Board This section provides instructions for connecting wires and cables to the Pipe Interface Board as illustrated below Refer to Section 3 Cable and Wire Standards page 26 for cable and wiring recommendations and specifications HHH P105 J102 HE P104 A P Nea We ed eae Pia N fale age ge QDOOO Figure 2 9 Pipe Interface Board Connections F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 21 Ref Description Connector Wire Gauge Pin Description 1 Pipe Interface Module 2 Video Coax In J102 3 6 pin Connector Alarms In 3 7 P103 4 4 pin Connector Alarms Out 1 3 P102 5 100 Resistor P105 6 Data In Out P105 AWG 26 16 1 Biphase C 2 Biphase C 3 Earth Ground 4 RxD 5 TxD 6 Signal Ground 7 Alarms In EOLR Supervised 1 2 P104 AWG 26 16 7 Ground 6 Alarm 2 5 Alarm 1 4 Earth Ground 8 Rel
35. se units at an environmentally compatible recycling facility per European Directive 2002 96 EC Environmental statement Bosch has a strong commitment towards the environment This unit has been designed to respect the environment as much as possible Power lines An outdoor system should not be located in the vicinity of overhead power lines electrical lights or power circuits or where it may contact such power lines or circuits When installing an outdoor system extreme care should be taken to keep from touching power lines or circuits as this contact may be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems SELV All the input output ports are Safety Extra Low Voltage SELV circuits SELV circuits should only be connected to other SELV circuits Because the ISDN circuits are treated like telephone network voltage avoid connecting the SELV circuit to the Telephone Network Voltage TNV circuits System ground Safety ground System video ground is indicated by the symbol Safety power ground is indicated by the symbol The system ground is only used to comply with safety standards or installation practices in certain countries Bosch does not recommend connecting system ground to safety ground unless it is explicitly required However if the system ground and safety ground are connected and grounding loops are causing interference in the video sign
36. sing four 4 corrosion resistant stainless steel studs not included NOTICE A stud diameter of 6 4 mm 1 4 in or 8 mm 5 16 in able to withstand a 120 kg 265 Ib pull out force is recommended 5 Attach the 3 4 in 20 mm watertight pipe fittings not supplied to the holes of the Power Supply Box through which you will run the power video and control data wires Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 12 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 3 1 Attach Cover Door 1 Compress the bottom hinge pin by pushing the pin lever down and then rotate it behind the Hinge Pin Stop The power box Cover Door provides a Hinge Pin Stop to hold the bottom hinge open while attaching the door Figure 2 2 Align Cover Door Hinge to Power Box Power Supply Box 5 Hold Hinge Pin Open Cover Door 6 Open Position Align Top Hinge 7 Hinge Pin Stop Align Bottom Hinge 2 Open the top hinge by pushing its pin lever outward and holding it open Note Both Hinge Pins must be fully compressed to open unlock the female hinges of the Cover Door before proceeding to the next step 3 While holding the top hinge pin open position the Cover Door to the Power Supply Box AJOJ NM eB and align its hinges 4 When the hinges are aligned release the top hinge pin to engage its mating hinge on the power
37. t Installing the Roof Parapet Mount en 25 CAUTION If you feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over 5 Hold the housing firmly in position and alternately tighten the two 2 5 mm Allen head mounting screws from above to a torque value of 10 12 N m 90 105 in lbs CAUTION You must tighten the two mounting screws to a minimum torque of 10 12 N m 90 105 in lbs to ensure a proper seal between the arm and the housing 6 Rotate the arm to swing the AutoDome out from the roof and into position 7 Tighten the three 3 10 mm 3 8 inch stainless steel hex bolts on the bracket to lock the Parapet Arm in position Refer to Figure 2 12 Page 24 for an illustration CAUTION Do not over tighten the bolts The maximum torque is 34 N m 25 ft lb Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 26 en Cable and Wire Standards AutoDome Roof Parapet Mount 3 Cable and Wire Standards CAUTION Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes CAUTION All wires for installation applications must be routed through a grounded conduit 3 1 3 2 3 3 3 3 1 Power 115 230 VAC Copper Wire To comply with local codes Wire Distance Guide for Pendant
38. th an RS232 RS422 Controller An AutoDome with a fiber optic module is prewired to operate with Biphase signals only This section describes the procedures necessary to control a VG5 series AutoDome fitted with a fiber optic kit using an RS232 controller or a Pelco RS422 controller To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 controller you must run control wires from the controller to an LTC 4629 head end fiber optic module Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 34 en Cable and Wire Standards AutoDome Roof Parapet Mount 3 5 1 Connecting to an LTC 4629 Head End Data Video Transceiver 1 Connect the RS232 cable TxD from the controller to the RS232 RxD port pin 1 of the LTC 4629 2 Connect the ground wire of the controller to Pin 2 on the LTC 4629 3 5 2 Configuring the VG5 AutoDome 1 Disconnect the power to the VG4 power supply unit then open the unit 2 Remove the green Serial Communications wire from the P106 connector 3 Remove the 100 Q resistor across the C and C pins 4 Cut the five wires from the green Serial Communications wire mating connector Ensure that the insulation covers each wire to avoid wires from touching 5 Cut back the insulation on the blue ground wire a
39. the slide switch on the main board to the camera head is positioned toward the LEDs default CAUTION Bosch recommends that multiple RS485 connections be arranged as a connected series of point to point multi dropped nodes as a line or as a bus It is not recommended to arrange RS485 connections as a Star ring or as a multiple connected network Star and ring topologies may cause signal reflections or excessively low or high termination impedance Wire Type 2 wire shielded twisted pair Distance 1219 m 4000 ft Maximum Baud Rate 57 6 kb Gage 0 511 mm 24 AWG Wire Impedance 120 W Slide Switch Toward LEDs factory default F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Cable and Wire Standards en 33 The following figure illustrates the connections for RS485 connections Figure 3 6 Connections for RS485 Operations 1 C Biphase T AutoDome Data In Out 2 C Biphase 8 P105 P106 Connector 3 Earth Ground 9 Head End RS485 4 RxD 10 Data 5 TxD 11 Data 6 Signal Ground 12 Ground SS Figure 3 7 Position of CPU Switch for RS485 Operation camera module not shown for clarity Switch Location LEDs RS485 CPU Module Note To access the CPU switch you must remove the bubble from the pendant housing AJOJ NM eR 3 5 Fiber Optic Module wi
40. trip the threads when tightening the Pipe Interface Board retaining screws Daa meas i Pe e Figure 2 11 Pipe Interface Board to Dome Cap Assembly 1 Interface Board 2 Retaining Screws 3 3 Pendant Mounting Screws 2 Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 24 en Installing the Roof Parapet Mount AutoDome Roof Parapet Mount 2 7 Attach Pendant to Pipe and Tighten 1 Before attaching the Pendant visually inspect the Pendant dome and the Interface Board connectors for any blocked pin holes and bent pins 2 Tilt the Pendant enough to place its mounting hook on top of the its housing over the recessed hinge pin of the Dome Cap Figure 2 12 Pendant to Roof Pipe Mount Attachment 1 Tilt Dome 2 Hook and drop 2a Dome Cap 2b Recessed Hinge Pin 2c Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mounting screws to a minimum torque of 10 12 N m 90 105 in lbs 3 Drop the Pendant down slightly to engage the dome hook and hinge pin of the Dome Cap allowing the dome to rotate around the hinge pin 4 Rotate the dome housing down to a vertical position and gently push upward to engage the connector on top of the dome housing F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Moun
41. ule to the camera head inward and away from the LEDs Wire Type 3 wire TXD RXD common Distance 15 m 50 ft Maximum Baud Rate 57 6 Kb Voltage 15V Termination 100 Q Slide Switch Away from LEDs factory default Figure 3 4 Connections for RS232 Operation 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 P105 P106 Connector 3 Earth Ground 9 Head End RS232 4 RxD 10 TxD 5 TxD 11 RxD 6 Signal Ground 12 Ground Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 32 en Cable and Wire Standards AutoDome Roof Parapet Mount 3 4 3 Figure 3 5 Position of CPU Switch for RS232 Operation camera module not shown for clarity Switch Location LEDs RS232 CPU Module AJ OO MD e Note To access the CPU switch you must remove the bubble from the pendant housing Controlling the AutoDome via the RS485 Protocol 2 wire shielded half duplex differential multi drop 32 nodes 4000 ft cable limit RS485 is capable of controlling a true multi drop network and is specified for up to 32 drivers and 32 receivers on a single 2 wire bus The AutoDome uses the 2 wire mode although RS485 can be connected in a 2 or 4 wire mode NOTICE The wire shield must be tied to signal at both ends if 2 wire twisted pair is used After connecting the wires for RS485 operation make sure
42. upply Box to ensure that water cannot enter the box You must use water tight conduits and fittings to meet NEMA 4 standards NOTICE Power and I O cabling must be routed separately inside different permanently earthed metal conduits 3 Install all rough wiring including power control video coax alarms I O relay I O and fiber optic cabling Refer to Section 3 Cable and Wire Standards page 26 for video and control protocol methods 4 Analog AutoDome If you plan to use the RS232 or RS485 protocol to control the AutoDome refer to Section 3 4 2 Controlling the AutoDome via the RS232 Protocol page 31 or Section 3 4 3 Controlling the AutoDome via the RS485 Protocol page 32 for instructions on configuring the AutoDome to accept these protocols WARNING External interconnecting cables are to be installed in accordance to NEC ANSI NFPA7O for US application and Canadian Electrical Code Part CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation A readily accessible 2 pole disconnect device with a contact separation of at least 3 mm must be incorporated 5 Choose the appropriate VG5 AutoDome model indoor or outdoor for the environment in which it will be used 6 Purchase the appropriate mounting hardware to use depending o
43. via Biphase 29 3 4 2 Controlling the AutoDome via the RS232 Protocol 31 3 4 3 Controlling the AutoDome via the RS485 Protocol 32 3 5 Fiber Optic Module with an RS232 RS422 Controller 33 3 5 1 Connecting to an LTC 4629 Head End Data Video Transceiver 34 3 5 2 Configuring the VG5 AutoDome 34 3 6 Audio Cables 35 Bosch Security Systems Inc Installation Guide F 01U 250 236 1 0 2011 08 4 en Table of Contents AutoDome Roof Parapet Mount 4 Alarms and Relay Connections 37 4 1 Alarm Inputs 37 4 2 Configuring Supervised Alarms inputs 1 and 2 37 4 2 1 Configuring a Normally Open Supervised Alarm 37 4 2 2 Configuring a Normally Closed Supervised Alarm 38 4 3 Configuring Non supervised Alarms inputs 1 through 7 39 4 3 1 Configuring a Normally Open Non supervised Alarm 39 4 3 2 Configuring a Normally Closed Non supervised Alarm 39 4 4 Alarm Outputs 40 4 4 1 Configuring a Dry Contact Relay 40 4 4 2 Configuring an Open Collector Output 40 F 01U 250 236 1 0 2011 08 Installation Guide Bosch Security Systems Inc AutoDome Roof Parapet Mount Important Safety Instructions en 5 1 1 1 Important Safety Instructions Read follow and retain all of the following safety instructions Heed all warnings on the unit and in the operating instructions before operation Safety precautions DANGER High risk This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product