1. The product should only be used in dry indoor areas Never use the product immediately after it has been brought from a cold room into a warm one The condensation that forms could damage the device Allow the device to reach room temperature before switching it on This may take several hours Only then should the product be installed connected to the supply voltage and put into operation Never touch the remote switch or the connected devices cables with wet or damp hands Make sure that the insulation of the entire product is neither damaged nor destroyed Always check the product for damage before using it If you detect any damage do NOT connect the product to the supply voltage Life threatening danger If the product is not operated for a longer period disconnect the product from the supply voltage Avoid the following adverse ambient conditions at the installation location or during transport Moisture or excessive air humidity Extreme cold or heat Dust or flammable gases vapours or solvents Strong vibrations Strong magnetic fields such as those found near machines or loudspeakers Operation of the remote switch is only permitted if itis installed in an approved installation box The device is completely maintenance free For this reason you should never open it Please let a professional workshop carry out the necessary maintenance and repairs 16 14 Tips and notes Ranges and interference T
2. General information Programming the timer c Starting the timer process d Prematurely switching off the timer process e Deactivating the timer function f Deactivating the programmed timer ov a Assigning further addresses address types b Deleting addresses and address types Resetting to the delivery state Handling Tips and notes Disposal Brief operating instructions ie Declaration of conformity DOG c scessessecssseeseestecsesecneeseesteesteeneesecneesteseeateeeee 1 Prescribed use The flush mounted remote switch FS20 SU 3 is only suitable for use with the FS20 wireless control system It must be operated in a flush mounted socket A consumer load connected to the remote switch please see the technical specifications and features can be wirelessly switched on or off via the wireless control system s transmitters Another feature is the integrated programmable timer function Any use other than the one described above may damage the product and can also increase the risk of short circuit fire electric shock etc No part of the product may be modified or adapted The device may only be operated when its casing is fully closed All the safety instructions and installation notes in this manual must be observed without fail 2 Scope of delivery Remote switch User manual 3 Explanation of icons The icon with a lightning flash in a triangle is used to al
3. control it later by remote control co Check that all connections are securely fixed to the installation terminals Connection for 230 V lamps or other 230 V consumer loads ER L i 230 VIAC 1 LL NN Connection for rma halogen transformer 2 with 12 V 3 halogen lamps L 230 V AC S OJO ole tv 1 LL NN 4 1 Input connection to the supply voltage 230 V AC 50 Hz L black N blue 2 Buttons with cables red cable with wire end sleeves do not shorten extension possible using the terminal strips or socket terminals 3 Light bulb 230 V AC 4 halogen transformer with 12 V downstream lamps d Insert the remote switch into the installation box and then install the button if you are using a deep installation box Otherwise the installation box in which the remote switch is installed must be closed with a suitable cover 8 Initial operation and programming a Initial operation Switch on the electric circuit in which the remote switch and the lamp or the standard halogen transformer with the 12 V lamps or other consumer loads are installed Test whether the remote switch works using the connected button Press the button briefly gt Lamp consumer load on Press the button briefly again Lamp consumer load off IS Please note In order to be able to control the remote switch from a remote control programming to at least one address type from t
4. may lead to the destruction of the device a fire or an electrical accident Note the varying maximum load capacity Only use approved installation cables Flexible cables are not permitted in fixed installations The only exceptions are the control cables that are soldered to the device and that are fitted in the factory with wire end sleeves to ensure correct wiring If you need to lengthen the control cables you must use suitable terminal strips Do not shorten the control cables The product may only be used in dry indoor areas The accident prevention regulations established by the Employer s Liability Insurance Association for electrical equipment and facilities must be adhered to in commercial facilities Consult a skilled technician if you have doubts about the mode of operation safety or connection of the device Handle the product with care knocks blows or even a fall from a low height can damage it 7 Preparing for operation installation Before assembling and using the device make sure you take note of all the safety and assembly instructions in this user manual Only people who are appropriately trained are permitted to carry out work on voltage carrying parts If you are not appropriately trained please consult a qualified electrician who is authorised to carry out such work Any incorrect work carried out on the supply voltage may lead to a fatal electric shock Not only do you endanger your life you also
5. only be supplied via the public power supply 230 V AC 50 Hz This product is not a toy Devices operated via the supply voltage should be kept out of the reach of children Therefore take particular care when children are around Do not leave packaging material lying around This may become a dangerous plaything in the hands of children To connect the device to the supply voltage as well as the consumer load or loads work must be carried out on the supply voltage or on live voltage carrying parts First of all switch off the electric circuit in which the wireless transmitter is to be included For this purpose switch off the respective circuit breaker or remove the mains fuse in the house distribution Make sure that nobody accidentally switches on the electrical circuit safety warning on the in house distributor mechanical block etc Then use a suitable measuring device to check whether the affected electric circuit is fully voltage free The same applies when replacing the fuse Operation of the remote switch is only permitted if it is correctly installed in an installation box The installation box must have a suitable cover Only people who are appropriately trained are permitted to carry out work on voltage carrying parts If you are not appropriately trained please consult a qualified electrician who is authorised to carry out such work Make sure you only load the product up to the capacity indicated An overload
6. switch switches off automatically All the programmed data is permanently stored in an integrated memory even when a power failure occurs The remote switch should be installed in a standard flush mounted socket or a flush mounted distributor When installed in a deep flush mounted box it can also be installed behind a flat installation switch button The maximum output load capacity of the remote switch is 1380 VA IS Please note This user manual refers primarily to operation using a remote control from the FS20 wireless control system with 2 buttons per channel When using other remote controls please refer to their respective user manuals 6 Safety instructions The product s guarantee becomes invalid if the product is damaged as a result of failure to observe these operating instructions We do not assume any liability for any resulting damages Nor do we assume liability for damage to property or personal injury caused by improper use or failure to observe the safety instructions In such cases the product s guarantee becomes invalid Do not use this product in hospitals or medical institutions Although the FS20 wireless control system only emits relatively weak radio signals these may cause life support systems to malfunction This may also be the case in other areas For safety and licensing CE reasons any unauthorised alterations to and or modification of the product are not permitted Voltage power may
7. the connected lamp or other consumer load can be switched on and off using a button connected to the remote switch Switching on off Briefly press the control button connected to the remote switch The consumer load s switch status changes each time you press the button on off on off etc IS Do not press the button for longer than a maximum of 5 seconds otherwise you will activate the programming mode 11 10 Timer function a General information The remote switch can also be used as a timer As soon as a switching time has been programmed 1 second to 270 minutes 4 hours 30 min the remote switch remains switched on for the programmed length of time after each power on command It switches off automatically after this time has elapsed IS Please note A remote control for the FS20 system is needed to program the timers Once a timer is programmed it can only be stopped by deactivating the timer functions b Programming the timer 1 Simultaneously press the button combination that is assigned to the remote switch on the remote control for one to three seconds 1 sec to 3 sec 2 The time measurement for the timer starts 3 Wait the desired amount of time and then press both buttons on the remote control again simultaneously for one to three seconds 1 sec to 3 sec The timer duration is now programmed IS Please note If the time measurement is not ended manually the timer programming mode will
8. OPERATING INSTRUCTIONS Version 01 13 CE Flush mounted remote switch FS20 SU 3 Item no 62 02 96 NRAD Introduction Dear customer Thank you for purchasing this product This product meets the requirements of both current European and national guidelines In order to preserve this condition and ensure the safe operation of the product we kindly ask you to carefully follow these operating instructions Please read the operating instructions completely and observe the safety and operation notes before using the product All company names and product names contained herein are trademarks of the respective owners All rights reserved Should you have any further questions please contact our technical advisory service Germany Tel no 49 9604 40 88 80 Fax no 49 9604 40 88 48 e mail tkb conrad de Mon to Thur 8 00am to 4 30pm Fri 8 00am to 2 00pm Table of contents S Or JS SA RIGA 12 13 14 15 16 17 Timer function Integrating the remote switch into the FS20 PUGS GO IS ccs cone nests oes sane E E E Scope of delivery Explanation of icons Technical specifications and features General information Safety instructions Preparing for operation installation Initial operation and programming Initial operation Programming peration Operation using the remote control Direct operation TM OTD
9. automatically be abandoned after 270 minutes 4 hours 30 min The timer is then programmed with a time of 270 minutes 4 hours 30 min c Starting the timer process There are two different ways to start the timer process Briefly press the control button connected to the remote switch Briefly press the right button of the assigned button combination on your remote control 12 d Prematurely switching off the timer process The remote switch can be prematurely and manually switched off at any time during the timer process There are two different ways in which to do this Briefly press the control button connected to the remote switch Briefly press the left button of the assigned button combination on the remote control e Deactivating the timer function Hold down the pair of buttons on your remote control assigned to the remote switch for 1 to 3 seconds simultaneously Now press the control button connected to the remote switch shortly Time programming mode is exited and the timer function is deactivated The remote switch can be used again in normal manual switching mode f Activating deactivating the programmed timer Ifyou do not wish to use the timer temporarily but intend to keep the programmed time the timer can be deactivated This puts the remote switch in normal manual switching mode When needed the timer can be used again without re programming the time Deactivating the timer Hold down the pa
10. endanger the life of others gt gt Only use approved installation cables for connecting the remote switch The installation location is amongst other things determined by two important factors Any cabling that may already exist Good radio reception We therefore recommend that you test the radio reception at the installation location It is very important to observe the order of the following steps during installation gt a First of all switch off the electrical circuit in which the remote switch is to be included For this purpose switch off the respective circuit breaker or remove the mains fuse in the house distribution Make sure that nobody accidentally switches on the electrical circuit safety warning on the in house distributor mechanical block etc gt Then use a suitable measuring device to check whether the affected electric circuit is fully voltage free b Strip the skinners of the power cable and the cable to the controlled consumer load to a length of 8 mm without damaging the bare wires Please note that no flexible wires are permitted in fixed installations The exceptions here are the control cables going to the control button Use without fail suitable wire end sleeves for the insulated multi wire conductors c Wire the remote switch with the installation cables as shown in the diagram below Connect the installation button for programming the remote switch even if you only intend to
11. ert you to potential personal injury hazards such as electric shock The icon with an exclamation mark in a triangle points to important instructions in this user manual that must be observed The hand symbol provides special information and advice on operating the device a gt 4 Technical specifications and features Operating voltage 230 V AC 50 Hz Power consumption 2 approx 0 5 W Breaking capacity 0 eee max 1380 VA 230 V AC 6 A 868 35 MHz up to 50 m in free field Reception frequency Range Dimensions 32 x 57 mm diameter Programmable timer duration 1 second to 270 minutes 4 hours 30 min Memory conservation also without power supply for instance during a power outage 5 General information In selecting the programmable flush mounted remote switch FS20 SU 3 you have purchased a versatile device that is easy to use and conveniently allows you to wirelessly switch electrical mains operated devices over long distances You can operate the remote switch via a button that can be connected to the device at distances of up to 50 m using the FS20 wireless control system s remote controls and using other remote switch transmitters Please also see section 14 In addition to the switch function a timer can also be programmed with a on time of between 1 second and 270 minutes 4 hours 30 min After this time has elapsed the remote
12. he FS20 address system is necessary The set up of the address type is carried out according to the user manual of the remote control transmitter The remote switch does not respond to radio commands in the delivery state b Programming After the function test program the remote switch to a specific channel of the remote control that is in use Press the control button connected to the remote switch for at least 5 seconds The remote switch is now in learning mode Press the required button on your remote control Once the remote switch has received the code the associated button combination on the remote control can be used to switch the consumer load connected to the remote switch e g a lamp See the above information under item a IS If required you can repeat these programming steps using another button on the remote control or another remote control channel To do this proceed again as described above 10 9 Operation a Using the remote control IS You can find detailed instructions regarding operation of the respective remote control transmitter in its accompanying user manual Here we only provide operating instructions for a remote control transmitter with two buttons per remote control channel Switching on Briefly press the right button of the programmed button combina tion Switching off Briefly press the left button of the programmed button combination b Direct operation If required
13. he FS20 wireless control system works in the 868 MHz range which is also used by other radio services Therefore devices that operate on the same or neighbouring frequency may restrict both its operation and its range The specified range of up to 50 mis the free field range which means the range with visual contact between the transmitter and receiver In practice however walls ceilings etc between the transmitter and the receiver may affect and reduce the range Other causes of reduced ranges All types of high frequency interference Any buildings or vegetation Conductive metal parts that are located near the devices or within or near their transmission path for example radiators metallised insulation glass windows reinforced concrete ceilings etc Influence on the radiation pattern of antennas due to the distance from the transmitter or receiver to conductive surfaces or objects also to human bodies or the ground Broadband interference in urban areas that reduces the signal to noise ratio the signal is no longer recognised due to this noise Interference radiation resulting from insufficiently shielded electronic devices for example operating computers or similar IS Please note Do not position several radio receivers directly next to each other as these may interfere with each other minimum distance 0 2 m we recommend 0 5 m or more 17 15 Disposal When the product is no longer usable dispose of i
14. ir of buttons on your remote control assigned to the remote switch for 1 to 3 seconds simultaneously The control lamp of the remote switch starts flashing Hold down the left button of the pair of buttons assigned on your remote control for more than 0 4 seconds but less than 3 seconds Now the remote switch can be switched manually The timer is deactivated Re activating the timer Hold down the pair of buttons on your remote control assigned to the remote switch for 1 to 3 seconds simultaneously The control lamp of the remote switch starts flashing Hold down the right button of the pair of buttons assigned on your remote control for more than 0 4 seconds but less than 3 seconds Now the timer is activated again and can be started when switched on the next time 13 11 Integrating the remote switch into the FS20 address system The remote switch can be integrated into the address system of the FS20 wireless control system via the latter s addressing scheme using single addresses function groups local and global masters More detailed information on exactly how this address system is structured is provided in the user manual of each transmitter belonging to the FS20 wireless control system a Assigning further addresses address types Up to four address types can be assigned to the remote switch within the address system of the FS20 wireless control system This makes it possible for example to operate the re
15. is prohibited These operating instructions represent the technical status at the time of printing Changes in technology and equipment reserved Copyright 2013 by Conrad Electronic SE V4 0113 01
16. mote switch remotely from several transmitters with the same or different address types You can find more detailed information on the address system in the user manual of each remote control belonging to the FS20 wireless control system IS To assign several address types to the remote switch repeat the programming steps described in section 8 b You can create a list of up to four addresses or address types in the remote switch s memory b Deleting addresses and address types If you want to delete a reception channel from the saved list set the remote switch to the programming mode see section 8 b and press one of the buttons assigned to this remote switch on the respective remote control for longer than 0 4 seconds IS Afterwards the programming mode is automatically abandoned and the corresponding channel is deleted from the remote switch s address list 14 12 Resetting to the delivery state If required you can delete all the settings that are stored in the remote switch at once Proceed as follows Press the control button connected to the remote switch for at least 5 seconds The remote switch is now in programming mode also see section 8 b Press the control button again All stored addresses and the timer mode with its pro grammed timer duration are deleted or deactivated IS The remote switch no longer responds to any remote commands and must be programmed again see section 8 b 15 13 Handling
17. t in accordance with the applicable statutory regulations 16 Brief operating instructions Programming Press the button connected to the remote switch for at least 5 seconds Then press the required channel button on the remote control the button combination on the remote control now controls the remote switch Operation using the remote control Switching on Briefly press the right button of the channel occupied by the remote switch Switching off Briefly press the left button of the channel occupied by the remote switch Operation via control buttons Switching on Press the button briefly gt Consumer load on Switching off Press the button briefly again gt Consumer load off 18 17 Declaration of conformity DOC We Conrad Electronic Klaus Conrad Strake 1 D 92240 Hirschau Germany hereby de clare that this product complies with the fundamental requirements and other relevant regulations of directive 1999 5 EG IS You can find the declaration of conformity for this product at www conrad com 19 http www conrad com Legal Notice These operating instructions are a publication by Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau www conrad com All rights including translation reserved Reproduction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part
Download Pdf Manuals
Related Search
Related Contents
BACTEC MGIT 960 SEEDED CULTURE 「取扱説明書」をPDFにてご覧頂けます カタログ中の傘マークは安全注意輩項ですので必ず AVerMedia EH1004H digital video recorder ADM-5721-Electric Bicycle manual ( Universal Phonix HU530GFU mobile phone case D-series & E-series 「マスカット」は「東北電力生協」 と提携しています。 le rapport d`activité 2014 - Communauté de Communes Axe Sud Copyright © All rights reserved.