Home
CPCI Rack – Single Euro with Conduction Cooling
Contents
1. MEN for PU2 PU3 PU4 PU5 PU6 and CCA Rack PSU controller on SMBus Software VxWorks This product is designed to work under VxWorks For details regarding supported unsupported board functions please refer to the corresponding software data sheets 13AD78 06 MDIS5 low level driver sources MEN for PU2 PU3 PU4 PUS PU6 and CCA Rack PSU controller on SMBus Software QNX This product is designed to work under QNX For details regarding supported unsupported board functions please refer to the corresponding software data sheets 13AD78 06 MDIS5 low level driver sources MEN for PU2 PU3 PU4 PUS PU6 and CCA Rack PSU controller on SMBus Software OS 9 This product is designed to work under OS 9 For details regarding supported unsupported board functions please refer to the corresponding software data sheets 13AD78 06 MDIS5 low level driver sources MEN for PU2 PU3 PU4 PUS PU6 and CCA Rack PSU controller on SMBus For operating systems not mentioned here contact MEN sales Documentation 20SYST016 3U CompactPCl CCA Rack User Manual CPCI Rack Data Sheet 2013 05 14 Page 5 Contact Information Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SA MEN Micro Inc Neuwieder Stra e 3 7 18 rue Ren Cassin 860 Penllyn Blue Bell Pike 90411 Nuremberg ZA de la Chatelaine Blue Bell PA 19422 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 Phone 33 0 450
2. 955 312 Fax 215 542 9577 Fax 33 0 450 955 211 info men de info men france fr sales menmicro com www men de www men france fr www menmicro com The date of issue stated in this data sheet refers to the Technical Data only Changes in ordering information given herein do not affect the date of issue All brand or product names are trademarks or registered trademarks of their respective holders MEN is not responsible for the results of any actions taken on the basis of information in the publication nor for any error in or omission from the publication MEN expressly disclaims all and any liability and responsibility to any person whether a reader of the publication or not in respect of anything and of the consequences of anything done or omitted to be done by any such person in reliance whether wholly or partially on the whole or any part of the contents of the publication The correct function of MEN products in mission critical and life critical applications is limited to the environmental specification given for each product in the technical user manual The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer Should the customer purchase or use MEN products for any unintended or unauthorized application the customer shall ind
3. for customized I O o 59 usable I O pins X4 for power supply Compliance with CompactPCI Spec 2 0 Rev 2 1 and IEC 61 076 4 101 connectors 3 slot o CPU system slot o Side card slot o Peripheral slot System slot on the left PSU 3U CCA Input 24VDC nominal 18 32V Output 5V 3 3V 35W Robust internal connection to rear panel outer connector X4 SMBus External I Os for key function Overtemperature shutdown 50 90 C adjustable by SMBus command Holdup time according to EN50155 Class S2 Temperature range operation o 40 C to 70 C with up to 85 C for 10 minutes according to class Tx EN50155 o Thermal resistance 0 4 K W Temperature range storage 40 85 C Relative humidity operation max 95 non condensing Relative humidity storage max 95 non condensing Shock according to EN 61373 Class B Vibration according to EN 61373 Class B F50C F11S in a special CCA version F12N in a special CCA version F14 in a special CCA version F15 in a special CCA version F17 in a special CCA version F18 in a special CCA version F19P in a special CCA version F21P in a special CCA version F22P in a special CCA version F75P in a special CCA version Page 3 Configuration amp Options Standard Configurations Article No 0701 0054 Options Slots I O Connectors PSU Mechanical Slots Size PSU Installation 1 system slot 1 side 200mm x 350mm x 9 36VDC 35W Horizon
4. CPCI Rack Single Euro with Conduction Cooling For standard 3U cards within CCA frames 3 slot 3U backplane System slot left horizontal installation Outline 200 mm x 350 mm x 145 mm 4 MIL C 38999 connectors 59 user I O pins PSU 18 32 V 35 W 40 to 70 85 C operating temperature IP65 compliant For 40 to 85 C 3U CCA versions of MEN SBCs F11S F12N F14 F15 F17 F18 F19P F21P F22P F75P and for F50C This enclosure for CompactPCl cards in 3U format allows to use standard boards that were designed for ventilated systems even in an environment which needs conductive cooling To do this all critical components are directly coupled to the housing to divert waste heat to the exterior wall This reduces the costs involved in the higher overhead of conduction cooling to the housing and no PCB space is lost on the boards for this cooling method This extremely robust enclosure is hermetically sealed against impacts from outside offers high vibration and shock resistance through the use of wedge locks as well as special connector types such as MIL C 38999 The standard front connectors of the boards are wired to four MIL C 38999 connectors three I O connectors CPCI Rack Data Sheet 2013 05 14 and one power supply connector at the rear side of the system inside the housing Both front and rear I O can be made available on these connectors and the pin out is always customized The standard CompactPCI boards a
5. emnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part In no case is MEN liable for the correct function of the technical installation where MEN products are a part of Copyright 2013 MEN Mikro Elektronik GmbH All rights reserved CPCI Rack Data Sheet 2013 05 14 Page 6
6. re fitted into a special CCA frame conduction cooled assembly and inserted into the system The system provides three CompactPCl slots for one CPU board with a side card and one I O board as well as a PSU slot with an H15 connector The distance between the slots on the backplane is greater than on standard backplanes The thermal resistance is 0 4 Kelvin Watt and the temperature class Tx for 40 W maximum performance for boards with an operating temperature of 40 to 85 C The enclosure is compliant with IP65 for protection against dust and humidity The system is suited for MEN boards F11S F12N F13 F14 F15 F17 F18 F19P F21P F22P F75P and F50C Page 1 Diagram X1 X4 Operational 1 Power Supply Q X2 X3 Operational 2 Maintenance Rear Panel CPCI Rack Data Sheet 2013 05 14 Peripheral Slot Side Card Slot System Slot PSU Slot Backplane o Li ee Page 2 Technical Data General System Characteristics Mechanical Specifications Connectors CompactPClI Backplane Power Supply Environmental Specifications Suited for MEN Boards CPCI Rack Data Sheet 2013 05 14 3 slots for 3U Eurocard boards in CCA frame Middle slot right of the system slot designed for a side card connected to the CPU board Conduction cooled 3U card horizontal Dimensions 200 mm x 350 mm x 145 mm Weight 4500g IP65 compliant 4 MIL C 38999 connectors X1 X4 X1 X3
7. tal card slot 1 peripheral 145mm slot Different number type of slots requires change of mechanical dimensions Individual signal routing to outer connectors Individual CCA frame Different outer connectors e g M12 Input voltage range 9 154V Wall mounting Connectors 4 MIL C 38999 Please note that some of these options may only be available for large volumes Please ask our sales staff for more information CPCI Rack Data Sheet 2013 05 14 Page 4 Ordering Information Standard CPCI Rack Models MEN delivers turn key systems completely installed hardware operating system accessories wired and tested Different rack sizes power supplies and backplanes on request For details please contact your local sales representative 0701 0054 CompactPCl rack for 3U cards in CCA frames 3 slots incl wide range PSU 24VDC 40 70 C 85 C qualified Tx IP65 Miscellaneous Accessories 0500 0131 Spare part four mating connectors for 0701 0054 according to MIL D38999 40 85 C Software Linux This product is designed to work under Linux See below for potentially available separate software packages from MEN 13AD78 06 MDIS5 low level driver sources MEN for PU2 PU3 PU4 PU5 PU6 and CCA Rack PSU controller on SMBus Software Windows This product is designed to work under Windows See below for potentially available separate software packages from MEN 13AD78 70 MDIS4 2004 MDIS5 Windows driver
Download Pdf Manuals
Related Search
Related Contents
入札公告 - NEXCO中日本 HP 15-f133wm PRORACER ZZ Pobierz i wydrukuj pełną wersję podręcznika () A 3000/3006/3100/3106 A 5000/5006/5100/5106 IT Vosstronics TransImp Q120U3 Advantys STB - LUCKINSlive Manual soportPC Copyright © All rights reserved.
Failed to retrieve file