1. Press and to select the desired language press again to save the selection m Battery model setting Press for battery model setting Press again for battery model selection Press and to select the battery model consistent with the real one press again to save the selection m Charge current setting Press for charge current setting Press again for charge current selection Press and to select the desired charge current press again to save the selection m Freguency setting Press for freguency setting Press again for freguency selection Press and to select the desired freguency press again to save the selection m Output mode setting Press for output mode setting Press again for output mode selection Press and to select the output mode press again to save the selection Attentions 1 Normal mode Normal output 2 Eco mode The output voltage is reduced by 20V to save energy under the precondition that the final output voltage of the machine is normal This mode is mainly applicable to road lighting and indoor outdoor lighting 3 Power saving mode When the load is above 200W the machine remains normal output When the load is below 150W the machine stops the output and after 1 minute starts the output when the machine again detects that the load is below 150W it stops the output 1 e cyclic output This mode is mainly applicable to refrig
2. The battery voltage is low indicator lights are on when the machine is at empty load and exceptional none is on when the machine is at any load Battery under None of the battery capacity indicator lights The battery voltage is low voltage indicator is on when the machine is at empty load and light is any of them blinks when the machine is at ceptional any load 8 4 Warranty Beijing Multifit Electrical Technology Co Ltd provides after sales service of the inverter under the precondition of the following 1 The warranty scope covers the inverter only 2 If any fault or damage occurs to the inverter in normal use Beijing Multifit Electrical Technology Co Ltd is responsible for repair for free within 15 months after the selling and responsible for paid repair after the 15 months 3 The paid repair also covers any of the following situations within 15 months after the selling e Inverter damage caused by not following the operation steps stated in the User Manual e Inverter damage caused by wrong wiring etc e Inverter damage caused by applying the inverter to improper function e Inverter damage due to transportation e Inverter damage caused by running the inverter in adverse working conditions stated in the User Manual e Inverter damage caused by the installation or application range nonconforming to the related international standards e Inverter damage due to unusual natural environment BeiJin
3. 0A 50A Charge Current Indicator Light 4 2 4 Parameter setting on LED control panel m Setting of eco mode Press Save for 5 seconds and then the machine turns to eco mode and Saving indicator light is on all the time press Save again for 5 seconds and then the machine turns to normal mode and Saving indicator light is off This setting is invalid when the machine is powered by mains supply m Setting of charge current The user chooses the proper charge current according to the power grid environment and battery capacity when the machine is powered by mains supply The default charge current is 10A press Charge for 5 seconds and then the machine increases the charge current and the corresponding charge current indicator light is on all the time press Charge again for 5 seconds and then the machine increases the charge current again and the corresponding charge current indicator light is on all the time This setting is invalid when the machine is powered by battery supply Note 25 50 75 and 100 are invalid when the machine is powered by mains supply and they respectively indicate the battery level when the machine is powered by battery supply 4 2 3 LCD control panel Startup Shutdown Page Up Page Down u Function Selection u Back 4 2 4 Parameter setting on LCD control panel m Language setting Press for language setting Press again for language selection
4. Preface Thank you for using the pure sine wave inverter of Beijing Multifit Electrical Technology Co Ltd This User Manual is about the functions and operation process of the inverter Please read this User Manual carefully before operation for correctly using the inverter and keep this User Manual properly for future reference in case of any problem Attentions m This User Manual is subject to change without notice and the latest version prevails m In case of any different understanding of this User Manual the interpretation from Technology Department of Beijing Multifit Electrical Technology Co Ltd prevails m Any copying or rearranging of any part or whole of this User Manual without the written permission from Beijing Multifit Electrical Technology Co Ltd is considered as serious infringement Table of Contents Chapter I Overview 1 1 Product verification 1 2 Safety precautions 1 3 Use precautions Chapter II Product Specification 2 Application range 2 2 Types 2 3 Technical specifications 2 4 Description of external structure 2 5 Overall dimensions 2 6 Installation dimensions 2 7 Optional accessories Chapter III Installation and Wiring of Inverter 3 1 Environmental conditions for installation 3 2 Wiring precautions Chapter IV Operation Guide of Inverter 4 1 Operation 4 2 Parameters Chapter V Performance and Parameters of Inverter 5 Capacity calculation 5 2 Performance and parameters Ch
5. apter VI Battery Management of Inverter 6 1 Battery model selection 6 2 Battery insertion Chapter VII Monitoring Chapter VIII Maintenance 8 1 Daily maintenance 8 2 Periodic maintenance 8 3 Fault diagnosis and handling 8 4 Warranty Chapter I Overview 1 1 Product verification Before unpacking please check whether the packing container is damaged due to the transportation After unpacking please check whether the inverter and accessories are in normal conditions and whether the rated values on the nameplate are consistent with that in your order requirements In case of any exception please contact the supplier or Beijing Multifit Electrical Technology Co Ltd 1 2 Safety precautions oe ate ra jE jj ea Warning danger Attentions 1 Do not install the inverter which is damaged or short of any part 2 Hold the bottom of it when carrying the machine for fear that the main body might drop down to injure anyone 3 Do not place any liquid on above the machine for fear that the liquid might spill onto the machine 1 3 Use precautions 24 f FB Warning electric shock Dangers 1 Make sure that the power is shut off before wiring 2 Have an electrical technician wire the machine up 3 Have the grounding terminal reliably grounded 4 Do not touch any terminal by hand 5 Make sure that the battery polarity is correct gt XE ri HEX Warning danger Attentions 1 Make sure that the voltage of
6. atic over temperature protection m Overload protection When the actual load is 50 over the rated load the machine enables 10s overload protection when the actual load is 100 over the rated load the machine enable 1s overload protection m Output short circuit protection When the output short circuit occurs the machine enables short circuit occurs within 0 1s m Self check and report In case of any exception in running the machine automatically analyzes the reason and gives out audible visual alarm m Cycle by cycle current limiting The cycle by cycle current limiting prevents the damage caused by high current switching loading unloading short circuit or impulse Chapter VI Battery Management of Inverter 6 1 Battery model selection Battery supply duration calculation The battery supply duration mainly depends on the factors such as load capacity battery capacity ambient temperature battery end of discharge voltage etc Generally to calculate the battery supply duration it is a way to calculate the battery discharge current and then look up the discharge time in the battery discharge curve The battery discharge current can be calculated according to the empirical formula discharge current Inverter capacity VA x power factor average battery discharge voltage x efficiency When to calculate the actual load discharge time it only needs to replace the above inverter capacity with the actual load capacity T
7. ely shutting down system safely and automatically sending alarm comprehensively such as autodialing to send call alarm autodialing to send mobile phone message alarm and sending E mail alarm etc so the user need not worry about that the mains supply failure may cause any loss to any system or archive The system is capable of necessary emergency handling instantly and also capable to record the information of the recent days In addition the Windows NT service function of PowerManagerll enables program execution before the user logs on to the computer so the system can automatically monitor and manage the inverter without any administrator Supported operating systems This version of PowerManagerll supports Windows operating systems only including MS Windows 98 MS Windows Me MS Windows 2000 MS Windows XP MS Windows 2003 MS Windows Vista it me RE Warning danger Attentions If the user has any question please refer to the monitoring help there is detailed description available Chapter VIII Maintenance 8 1 Daily maintenance Different faults may occur to the inverter due to the changes of working environment such as the influence by temperature humidity smog etc as well as the aging of the internal components Therefore it is necessary to daily check and periodically maintain the inverter during storage and use Whether the sound or vibration of the machine is exceptional Whet
8. erator and air conditioner m Power supply priority setting Press for power supply priority setting Press again for power supply priority mode selection Press and to select the power supply priority mode press selection m Battery under voltage protection point settin Press for battery under voltage protection point setting again to save the Power Conversion enter Nr VZ Sro O C Press again for battery under voltage protection point selection Power Conversion Center wm eror Press and to select the desired battery under voltage protection point press again to save the selection gt um ra LEER E Warning danger Attentions 12V battery under voltage protection point 11V 10 5V 10V 9 5 V 24V battery under voltage protection point 22V 21V 20V 19 V 36V battery under voltage protection point 33V 31 5V 30V 28 5 V 48V battery under voltage protection point 44V 42V 40V 38 V m Battery capacity setting Press for battery capacity setting ann unt Power Conversion C enter wo M eoo Press again for battery capacity selection Power Conversion enter V vm Sooo Press and to select the battery capacity consistent with the real one press again to save the selection Chapter V Performance and Parameters of Inverter 5 1 Capacity calculation An electrical appliance whic
9. et an electrical shock Chapter VII Monitoring 53180 134 CELA TIROL Kc SEV flc BMW i i S o 60 120180240 300 BYPASS 1N 220 OUT 220 pov Sach EE Faith AE Q sess sers Queierrz wrs ruske O 5Bk rs ba Tuum BBR Tal richcomm HS PS SK IIA WRX Versionl 0 10 37 26 System View Control Help AA A FE As rit d tic AL PY Ui HE Aij CH FEL Input Voltage Battery Internal Output Voltage ME Capacity Temperature iE Frequency Load BATE TH EIE FY HL Yt FL JE JE UPS 1E JEMN EBS Eguipment Normal Mains i Normal UPS Non test Non bypass Wiring Supply Normal Status Status Battery Voltage SEG S Event Information TT AR Manufacturer UPS 5K 11A Version 1 0 Richcomm Introduction PowerManagerll system software to monitor inverter is applicable to local monitoring and network agent monitoring via COM port and USB port It clearly displays figures and graphs of the real time input output voltage frequency load temperature battery capacity and other data to help the user monitor the power supply quality It also sends control instructions to the inverter to control the latter to help the user manage the power more efficiently Moreover by preset control instructions 1t controls the inverter at a fixed time in case of mains supply failure or low battery potential it gives full play to the unmanned monitoring function by automatically saving information safely and accurat
10. g Multifit Electrical Technology Co Ltd Head Office Address Room812 Block B 3 Rongjingdong Street Beijing Economic amp Technological development Zone 100176 BeiJing China Factory Address No 15 KeChuang street Beijing Economic amp Technological Development Zone 100176 BeiJing China Tel 86 10 87227420 Email multifit multifitele com web Http www multifitele com
11. h is a load in a circuit is usually marked with the values of rated power rated current power factor and other parameters However there is much difference among different types of loads but there must not be much difference between the actual total power of the loads and the rated power of the machine so the total actual power should be the sum of active power of all the loads but not the simple sum of the rated power of all the loads Because mostly the loads are household electrical appliances and their power factor values are between 0 65 to 0 7 the total actual power can be the sum of the rated power of all the loads as for the loads of other types such as printer etc the active power must be the rated power multiplied by a certain factor according to the starting power and then is added to the sum On the basis of the total capacity of all the loads the inverter capacity can be determined according to the formula inverter capacity gt total capacity of loads gt 0 8 that is to say the total capacity of all the loads must be less than 80 of the rated capacity of the inverter because the impulse current of load startup and the future need for expansion must be taken into consideration Not all electrical equipment needs an inverter vice verse an inverter is not applicable to all electrical equipment A user to choose a load of an inverter must take into consideration the sizes features and importance of the load as well as the inf
12. he user can determine the proper battery model on the basis of the calculated battery supply duration according to the above formula Charging Three step charging respectively constant current charging constant voltage charging and pulse charging renders the battery always ready The charge current is adjustable so the use can choose the proper current to charge the battery 6 2 Battery insertion 24 fh FE Warning electric shock Caution m When inserting amp connecting the battery if the battery acid comes into contact with skin or clothing please instantly wash the skin or clothing by clean water and soap if it comes into contact with eyes please instantly flush the eyes by cold water for at least 20 minutes and instantly send the injured one to hospital for treatment To prevent danger the operator must wear safety goggles and safety clothing when operating on battery in particular the operator must keep the tools and jewelry away from the batter when operating for fear that any accident might be incurred When connecting the inverter with the battery please make sure that the battery polarity is correct for fear that the inverter might be damaged or accident might be incurred m Please do not replace the battery connecting wire without permission because nonconforming wire or nonstandard wire may cause damage to the inverter Please shut the power off and then connect the power grid for fear that one might g
13. her the heat of the machine is exceptional Whether the ambient temperature is too high Whether the load value is different from usual Whether the running of the cooling fan is exceptional 8 2 Periodic maintenance m To periodically check whether all the wiring of the inverter is reliable whether the line is well insulated and whether the line is damaged in particular to check whether there is overheat sign or other potential danger to the battery and input output terminal of the inverter and whether the fan of the inverter is in good condition To periodically conduct battery charging discharging test to activate the performance of the battery and prolong the service life of the battery The battery life depends on the ambient temperature and the discharge cycle times When the ambient temperature is about 20 C the average battery life is about 3 to 5 years when the ambient temperature is over 30 C the battery life is shortened accordingly For a new battery the capacity usually increases after few charging discharging cycles then remains stable and finally decreases after several hundred charging discharging cycles When the ambient temperature is within 20 C to 25 C it is recommended to charge and discharge a new battery for 2 to 3 times within the first two months and to charge and discharge it every 1 or 2 months later m To periodically clean the cooling fan properly itm RE Warning danger Attentions m Make
14. ine maintains output for 3s to 7s when the load is over 200 the machine maintains output for 1s shuts down and gives out long alarm sounds DC Input Input 12V 24V 48V Battery Voltage Battery 10V 16V 20V 32V 40V 64V Voltage Range AC Input Input 160 270VAC 95VAC 140VAC Voltage Range Input 45 55Hz 55 65Hz Freguency Range Factor Output As same as that of mains supply Voltage Accurac Freguency Accurac 13 7V 27 5V 55V Voltage 10A 20A 30A 30A 50A Current Time Protection Over temperature protection overload protection short circuit protection battery Function under voltage protection battery over voltage protection Machine lt 40Db 1mter Noise Working 20 50 C Ambient Temperatur e Working 5 90 no droplet condensed Ambient Humidit Working lt 1 500M Ambient Height 2 4 Description of external structure LCD control panel of inverter Battery terminals of inverter Connecting terminals of inverter 2 5 Overall dimensions 2 2 0 8 CPU Control Pure sine wave output High efficiency amp Saving ISKVACSKVA 2 6 Installation dimensions smm B J C O 0 SKVA IKVA 175mm 1 SKVA 2KVA 2 5KVA SKVA 2 4 1 Description of external structure ES nnn gg ii ISO 9001 Certification LED control panel of inverter BATTERY r Q a E o BATTERY SWITCH Battery terminal
15. le of AC110V Input Output Wires Model 500VA 1 000VA 2 000VA 3 000VA 4 000VA 5 000VA Wire 110VAC 110VAC 110VAC 110VA 110VAC 110VAC L OUT gt 1 Ont Configuration Table of AC220V Input Output Wires Mode 500VA 1 000VA 2 000VA 3 000VA 4 000VA 5 000VA 6 000VA 8 000VA 1 220VAC 220VAC 220VAC 220VA 220VAC 220VAC 220VAC 220VAC Wire 24m 8m E Configuration Table of Input Wires to Batte Mode 500VA 1 000VA 2 000VA 3 000VA 4 000VA 5 000VA 6 000VA 8 000VA l D C 2 8m l m 2m E lt 24V 4m Sm l m 16m 25m 35m Chapter IV Operation Guide of Inverter 4 1 Operation Startup when all wiring is in normal condition press On for 5 seconds and then the machine starts up Shutdown Press Off for 5 seconds and then the machine shuts down 4 2 Parameter setting 4 2 1 LED control panel m On Off Startup Shutdown m Save Eco Mode m Charge Charge Current Selection m Mains Mains Supply Indicator Light m Battery Battery Supply Indicator Light m Output Output Indicator Light m Fault Fault Indicator Light m Saving Eco Mode Indicator Light m UNDER VOITAGE Battery Under voltage Over voltage Indicator Light m CHARGING Battery Charging Indicator Light m 10A 10A Charge Current Indicator Light m 30A 30A Charge Current Indicator Light m 5
16. luence by harmful power on the load Loads are generally classified into linear loads including resistive inductive and capacitive loads and non liner loads containing rectifier circuits such loads are also called rectifier loads including computers and the peripheral equipment An inverter is applicable to resistive loads and capacitive rectifier loads The startup of inductive or capacitive loads causes an impulse current even the normal running of a computer or any other rectifier load leads to the current peak factor being 2 to 3 that is to say the current peak value is 2 to 3 times of the effective current value Therefore a user to choose an inverter must take account of such feature and leave a margin to the inverter As for the inductive loads with small power factors such as air conditioner etc the starting current is very high which may be 5 to 7 times of the rated current and the startup is very frequent so the ordinary small or medium inverter is not applicable unless enough margin has been left 5 2 Performance and parameters m Battery under voltage Over voltage protection oo Battry Under Battery Under voltage Protection voltage Alarming voltage Protection Point Point Point 10 5V 16V 32V 64V m Over temperature protection When the internal temperature of the inverter reaches 35 C the fan begins working to dissipate heat when the internal temperature reaches 100 C the machine enables autom
17. s of inverter Connecting terminals of inverter 2 5 1 Overall dimensions s e Aue CE ISO 9001 Certification 2 6 1 Installation dimensions Model A B J oJ 0 5KVA 5KVA 2 4 2 Description of external structure LCD control panel of inverter Battery terminals of inverter Connecting terminals of inverter 2 5 2 Overall dimensions 2 7 Optional accessories m RS232 monitoring product communication line m USB monitoring product communication line m Battery cable m Input output cable m Remote LCD monitoring panel Chapter III Installation and Wiring of Inverter 3 1 Environmental conditions for installation m The machine must be installed in a well ventilated place m The ambient temperature must be within 20 C to 50 C m The ambient humidity must be lower than 95 RH to ensure there is no droplet condensed m The machine must not be installed in the place where there is corrosive or explosive gas 3 2 Wiring precautions lim ra Hx x Warning danger Attentions m Make sure that the power is shut off before wiring m Make sure that the AC voltage is as same as the required voltage of the machine before wiring m Make sure that the battery voltage is as same as the required voltage of the machine before wiring m Make sure that the battery polarity is correct before wiring Please choose the wire with proper diameter from the wire configuration tables below Configuration Tab
18. sure that all power is shut off before replacing the cooling fan m Make sure that any tool should not touch any battery terminal or radiator when dismounting the cooling fan m Directly blow away the dust in the machine if there is too much dust there m Have an electrical technician replace the battery and deliver the replaced battery to recycler for treatment Inverter Maintenance Record Table Maintenance Maintenance Content Maintainer Signature Time 8 3 Fault diagnosis and handling Machine cannot be After the user presses On the inverter The battery connection is started does not respond incorrect or the battery switch is not closed Machine cannot be After the user presses On the buzzer The pressing duration is too normally started gives out a sound and then the machine short The pressing must last shuts down for 5 seconds at least After the user presses On the buzzer There is output short circuit or sounds all the time and the fault indicator the actual load is 15096 of the light is on all the time rated load After the user presses On the buzzer The battery over voltage under sounds all the time and the battery under voltage protection is enabled voltage indicator light is on all the time Machine is The inverter only runs with light load The power line is loose protected when with heavy load Battery capacity All the battery capacity indicator lights are
19. the AC circuit is as same as the rated voltage of the inverter 2 Do not disconnect any terminal while the machine is powered on and running 3 Do not touch the battery switch while the battery is being charged at a high current 4 Do not clog the ventilation hole of the machine 5 Do not wipe the machine casing by wet cloth Chapter II Product Specification 2 1 Application range m Important computer systems in securities exchanges bank hospitals etc m Fire protection lighting monitoring and other systems in buildings m Transportation systems covering lighting systems in expressways tunnels metros airports etc m Production experimental and other equipment which must not be powered off m Household electrical appliances 2 2 Types m Household inverter m Solar inverter m Pure inverter 2 3 Technical specifications 500VA 1 000V 2 000V 3 000V 4 000V 5 000V 6 000V 8 000VA m A A A A A 350W 700W 1 400W 2 100W 2 800W 3 500W 4 200W 5 600W Power Maximum 1 6A 32A 6 44 9 5A 12 7A 15 9A 19 1A 25 5A Output 32A 6 4A 12 8A 19A 25 4A 31 84 382A 50 9A Current 220VAC 1 110VAC 1 Voltage 50Hz 0 5 60Hz 0 5 Freguency Output Pure sine wave Waveform Distortion lt 3 Degree Inversion 80 85 Efficiency Overload When the load is 120 to 160 of the rated load the machine maintains output for Capacity 7s to 10s when the load is 160 to 200 the mach
Download Pdf Manuals
Related Search
Related Contents
SILABO DE INSTALACIONES I. DATOS GENERALES 1.1. Facultad “アルビクス” ビデオ/オーディオ コンバータ AD-80F ANNO 2015: LA RINASCITA DELL`UMANITA` Artwizz SeeJacket Leather Apri - Documentazione tecnica TP-LINK TL-WR1043ND router Massive Wall light 55360/47/90 User`s Manual Model 461995 Laser Photo / Contact Tachometer Mode d`emploi des indicateurs Copyright © All rights reserved.