1. 5 2 2 Measure There are 5 items Spot Line Area Rect Parameters and Save Setting in Measure menu NY Line ra ect Lt Rect aC Parameters Measure Sub menu Spot Measure 19 Press or button to select or deselect Selected spot is check marked Up to 4 spots can be selected at the same time Fusion Aisa Spot Target Selection Spot Measure Measure result on upper right LCD corner is temperature reading at location marked with Up to 4 spots can be selected Spot Measure Atiribute Press Hotkey button 2 until spot marker is flashing in yellow and then press Up Down w Left O and Right 2 buttons to move spot location to different directions press Enter button to enter Attribute Menu to set the emissivity and reference point After 2 seconds with no operation system will exit to real time Infrared view screen 20 Spot Measure Attribute Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current spot as reference point If selected all measure result will be relative value to this spot temperature Line Measure There are 2 line measure options vertical and horizontal Horizontal Line Measure Horizontal Line Measure Horizontal line is temperature sampling line and upper right LCD corner displays temperature measurement reading on vertical cursor line intersection After using HotKey button 2 select line
2. a BANG 1 o de 3 4 Point measure i 15 Ti and i indicates temperature value of point 1 2 3 and 4 respectively 13 10 11 Imaging mode Infrared visual fusion PIP and Superpose can be switched by pressing the or button Line measure the temperature value in the crossing of measure line and cursor line Area measure measure points within the area maximum minimum or average temperature is optional 12 18 Lower or upper limit temperature the lower and upper limit 13 14 15 16 17 19 temperature of the color code at the same time Storage medium IN indicates built in FLASH SD means SD card enter the Main menu Setup System Setup Storage Medium to adjust the storage medium USB symbol USBO means file transmission USB1 means video transmission enter the Main menu Setup System Setup USB to switch Color Code color palette Any kind of color code is available in the palette Time Display it displays the default date and time Battery condition indicates current battery power condition Temperature unit there are three options 1 K enter the Main Menu Image Analysis Setup Temp unit to switch 5 2 Main Menu Menu and sub menu items 14 Enter the Main Menu Long press Enter button when not in Hotkey mode to enter main menu as shown below not if press Enter button too long instead of enter main menu triggers manual rectif
3. The quality administration system of this product during the process of R amp D and production has been approved in accordance with ISO9001 standard 3 Compatibility with Previous Versions This IRSee Software version supports all file and data created by any IRSee Software version 4 Compatibility with Infrared Camera This Software supports all JPEG format image recorded by Infrared Camera I Software Installation Welcome to Use IRSee software 1 Introduction The IRSee Report version has a friendly user interface 4 methods for measure analysis and the function to save analysis report in Word PDF Excel and other formats 2 System Requirements The files of the IRSee software consist of IR image visual image and graphic file all of which are far bigger than normal text files thus the following standards of the computer hardware configuration should be met 2 1 Hardware Requirements CPU PENTIUM Dual Core 2 0GHz processor or faster 1Gbytes or more system memory 20G or bigger hard disk 1440x900 or higher resolution screen 2 2 Operating System IRSee Software is compatible with Microsoft Windows 2000 XP Vista Windows 7 It provides a multi language version for users 3 Software Installation The instructions of IRSee software installation and necessary precautions before using this software will be given in detail hereinafter Please follow the instructions when installing IRSee softwar
4. Uncooled Focal Plane Infrared Cameras IRSee Report Software User Manual Table of Content I Software Installation 2 amaanaaanawawnnawanaaawanasananwnasasanaananana 1 NA ligo eie AA AA 1 2 System Requirements sesse ee ee ee ee ee ee 1 2 1 Hardware Configuration ees esse esse ee ee ee ge ee 1 2 2 Operating System ee ee ee Re ee Re 1 3 Software InstallatiON ese ee ke RR RA Re Re ee 1 4 Uninstall Software sees ee Re ee RR RA Re Re gee 3 EES EE OE EO Ne 3 IT Function Description ee ee ee Re Re Re Re ee ge 5 1 Image Import and Export ees ee esse ee ee ee ee ee ee ee ee ee ee 5 1 1 Image IMpPOnt aasa 5 1 2 Image EXDOR iese eg BANAL cede pai 5 Ese RE AE OE OE EE ER 6 2 1 Quick Access Toolbar i ese ee ee Re ee 6 2 2 le AE RE HE ER AE OE RE TE 7 2 3 Measuring Temperature Zone esse eke ee 17 2 4 Histogram Area ees ee ee ee ee ee ee Re ee ee ee ee ee 24 2 5 Line Profile Measurement Area sesse ee ee 26 2 6 Color Code Area ie ves Ek Ese DE EE BRA EES ee ge EES RA Ed di Ee 27 2 7 Label OR RR N EEN EE 28 2 8 Visible Light ee ee Re ee Re ee ee 30 1 Limited Liability Software does not guarantee the quality performance or applicability of any hidden special purpose The contents of this manual will be updated because of device upgrade or other various reasons Our company reserves the right to edit this manual without further notice 2 Quality Assurance
5. 2 2 6 USB Direct Transmission 15 2 2 6 1 Connection Click the Ribbon Settings gt gt USB Direct Trans ME USBPlayer DER Device disenabled or play error Connect a device set to USB Direct Trans mode for the device Click the device iron on PC software interface gt gt Open the device gt gt Play 2 2 6 2 Video Click the device gt gt Record Savein Desktop my Documents g 9 My Computer My Recent My Network Places Documents 9 19 me Dist IR Analysis Software DIRSee Report ami00727 2M111009 CJ MyDrivers photo neo CJUVSee Report Desktop My Documents ig My Computer My Network Save as type x Select a video path gt gt Input the name of the video file 2 2 6 3 Stop the video Click File gt gt Stop Recording 16 2 2 6 4 Pause Stop and Close Direct trans Click the Pause Stop and Close buttons under the File menu respectively to stop the current operation 2 2 6 5 Print Screen Click the Print Screen button and save the printed image into the Picture folder under the installation directory and name it by a time format 2 2 7 Panel It is mainly used for showing hiding each area a user can adjust the size and position of each display area as needed and then click the Save Settings to save the current settings and click the Reload Default Settings to recover 2 3 Measuring Temperature Zone The functional options in
6. 2 2 Direct Charging It is available to charge the built in battery with the adapter it is about 5 hours to fully charge a run out battery The indicator indicates orange in charging and remains green when fully charged 2 3 Attention for Using Battery Charger 3 Battery Charging can only be conducted inside of a house Do not short circuit the battery Do not put the battery in high temperature environment 26000 Never disassemble the battery or put it into fire which may cause explosion Do not try to modify the battery or the charger Li lon battery has no memory effect charging can be conducted at any time Please remove the charger from AD socket as soon as charging is completed Panel Function Summary In this manual long press means Long press button down for about 2 seconds and press or short press means press and release 3 1 Main Control Panel 1 Power LED Light After infrared camera is turned on the indicator functions as a power indicator in green functions as a charging indicator in orange indicating the battery is being charged now 2 HotKey button 1 Press to automatically focus and Long press to turn on off LED light 3 HotKey button 2 Press to switch between measured objects point line and area and fusion zone setting range of thermal superposing temperature color code temperature upper and lower limits and Long press to turn on off the laser 4 5 6
7. Type New UFPA micro bolometer IR Resolution 170 175 160x120 Detector 390 395 384x288 Pixel Spacing 25um 170 175 21 1670 1 m Standard Lens 530 398 21 1670 4 m 170 175 Wide angle 42 3270 1 m Optional Lens Telelens 10 871 m P 390 395 Wide angle 38 2870 3 m Telelens 11 8 571 2 m Spatial 170 175 2 3mrad Resolution 390 395 1 2mrad Thermal 170 175 0 050 300 Image Sensitivity 390 395 0 0650 3011 Quality Frame ie 50 60Hz Focusing Auto Motor 470 175 9 1 continuous stepping zoom ska within 1 4 multiples Digital Zoom gt 0 1 continuous stepping zoom 390 395 png R within 1 8 multiples Spectral Range 8 14um visible camera 2Mpixel spotlight YES display 3 5 Color 270 tiltable LCD Display Thermal visual thermal fusion Image modes Pa F picture in picture thumbnail gallery 170 390 20 C 100 C Temperature 20 C 250 C Standard Range 75 395 200 C 600 C Optional A 200 C 1200 C Optional B Acc rac 2 Cor 2 reading range select the Measure y bigger value Measure Auto Manual rectification 4 spots 3 areas available under real time mode max min and average temp line Mes oie Mode measure isothermal display temp differenda measure and temp alarm sound color Color Palette 12 Colors selectable including iron red rainbow black white and white black etc Image Setup Auto Manual adjust contrast brightness System Setup Date Time Temperature Unit C F K 10 Lan
8. Move a point Move the mouse to a point to be moved 18 et When the mouse status changes to left click to select the point Move the mouse Delete a point Select a measurement point to be deleted Click the x button to delete the current measured object 2 3 3 Line Analysis Create a line Arbitrary line Click the wal Create button to pop up a menu Click the Arbitrary Line button Set a starting point of the line in the thermal image to be analyzed Left hold and drag the mouse to the terminal point of the line Vertical Line Click the E create button to pop up a menu Click the a Vertical Line button Set the vertical coordinates of starting point of the line in the thermal image to be analyzed Left hold and drag the mouse to the vertical coordinates of terminal point of the line Horizontal Line Click the El create button to pop up a menu Click the Horizontal Line button Set the horizontal coordinates of starting point of the line in the thermal image to be analyzed 19 Left hold and drag the mouse to the horizontal coordinates of terminal point of the line Move and change a line Move Move the mouse to the position of a line to be moved When the state of mouse becomes left click to select it And then move it Change the positions of starting point terminal point Move the mouse to the position of the line to be moved When the state of mo
9. Select the starting point of the polygon in the thermal image to be analyzed Move the mouse and left click to add other vertices of polygon 21 22 Right click to stop adding the vertexes to create a polygon f the number of vertexes is equal to or more than 50 the system can stop adding automatically Move and Drag a Polygon Move Move the mouse into the polygon to be analyzed When the state of mouse becomes click to select it Move the mouse Zoom in out Move the mouse into the polygon to be modified When the state of mouse becomes a click to select it Move the mouse to a vertex to be modified JL When the state of mouse becomes click to select it Move the mouse to change the position of the vertex thus to modify the polygon Delete a Polygon Select the polygon to be deleted Click the xi button to delete the current temperature measurement object Add an ellipse Click the Bada Area button to pop up a menu Click the Ellipse Select the starting point of the ellipse in the thermal image to be analyzed Drag the mouse to create an elliptical analysis area Move and Drag an Ellipse Move Move the mouse into the ellipse to be moved When the state of mouse ME a click to select it Move the mouse Zoomin out Move the mouse into the ellipse to be modified When the state of mouse Becomes click to select it Move the mouse to the eigh
10. or Right 2 to switch to Monitor in the Display Device then get thermal image in the Monitor Converter cable Video cable Insert Converter cable to Multifunctional interface for audio output or video output then insert Common earphone to Converter cable finally tune voice annotation according to 4 5 5 Operation Menu 5 1 Display Summary All items can be selected by short pressing HotKey 2 button 12 Note Long press Hotkey 2 button will turn on off laser sight The selected item is flashing in yellow color If no operation in 2 seconds after selection Hotkey mode will exit automatically SO MAY Real time Thermal Image Interface Auto focus Press Hotkey 1 button for auto focus Area Measure Box 3 areas can be selected in area measure box enter the Main Menu Measure Rect to operate AF Area objects need focused can be displayed in the area to achieve Auto focusing effect Horizontal measuring line Horizontal sampling line Enter the Main Menu Measure Line to select the function Temperature distribution curve sample temperature distribution curve of the measure line Point measure cursor 4 measure points can be selected Enable the Main Menu Measure Spot to operate Symbol for 1 8X digital zoom display the multiple of digital zoom under the real time measurement mode or the preview mode click the 4 or w key to change infrared images step by step in the multiple of 0 1
11. 0 390 temp range is only from 20 C to 100 C IR Lens For 170 175 infrared camera there are 3 options 11mm standard lens 5 5mm wide angle lens and 22mm telephoto lens For 390 395 infrared camera there are 3 options 21 5mm standard lens 11mm wide angle lens and 40mm telephoto lens Press or button to select correct IR lens for best measurement result after installing optional IR lens for example if remove wide angle lens telephoto lens from device the device is with standard lens please set 11mm or 21 5mm A The camera may need 20 seconds to readjust a new lens before it can work properly Temp Unit Press or gt to select Temperature Unit from O 0 and K 0 9 5 0 32 K 273 15 0 Ambient Temp For more accurate measure result set Ambient Temp to correct environmental temperature Press Cor gt once to change Ambient 34 Temp 0 10 Long press or gt wil change Ambient Temp in 10 interval Reference Set reference spot or area to display measure results as relative value Ref Temp Press or 2 once to change Ref Temp 0 10 Long press Cor will change Ref Temp in 11 interval This option is only active when set Ref Temp as reference Image Reverse Press Enter button to reverse palette for thermal image display Press Enter again to switch back Clear Screen Press Enter button to clear all items at thermal image area L amp S Auto Manual Mode Press Enter button to s
12. 23 60 C 2 5 1 Show hide grid lines Click the E Grid button to switch the grid display and hide mode 2 5 2 Set the background color Click the g background color button to pop up color selection dialog box Select a background color Click the OK button to confirm the background color 2 5 3 Save the line profile measurement image Click the H button to pop up the file selection dialog box Select an image format Check set the path to save the image Click the Save button to save the line profile measurement image 2 5 4 Settings Click the Va button to select the line profile as customized 26 2 6 Color Code Area Pallete pun 38 36 ME n 39 6 S 32 30 a 163 3 5 28 26 24 22 20 It is available to adjust the type of color code 12 kinds of color bars are available A User can also adjust the maximum or minimum temperature and isothermal upper and lower limits any out of range temperature can not be supported If the dew point is selected the corresponding color code of below the dew point temperature will be unified 2 6 1 Default maximum or minimum temperature and upper and lower limits of isothermal color Click the button to reload default settings 2 6 2 Adjust upper and lower temperature Method 1 e Move the mouse tom gt the upper and lower temperature on left side of the color bar te When the mouse s status turns please
13. 7 Direction buttons Up 4 Down ww Left O and Right 2 keys have different usages in different modes In main menu direction buttons are used for moving selected items or changing slide bar value In real time Infrared view mode directions buttons provide one click access In Fusion or Superpose imaging mode press Right gt to make better overlaying between visual and infrared images Press Left O and Right 2 to select preview images Press Left O to freeze Infrared image and press again to unfreeze Press Up 4 or Down w to switch between normal view and 1 8x zoom continuous After press Hotkey button 2 in area measure in yellow flashing Select measured spots press Up 4 Down w Left O and Right 3 button to move the spot in the same direction Select the measure line and sampling line press Up 4 Down W Left O and Right gt button to move the line in the same direction Select area box in move menu press Up 4 Down w Left O and Right gt buttons to move area box and in size menu press Up and Down to resize the vertical direction area box press Left O and Right gt buttons to resize horizontal area box Select Fusion area in fusion imaging mode press Up 4 Down MA Left O and Right gt buttons to move infrared image area at same direction press Up 4 Down w buttons to resize vertical fusion area and press Left O an
14. Laboratory Eguipment Manufacturer EN www mrclab com CE iNet CS Operation Manual for Infrared Cameras IR CAM B 70 I 75 B 90 I 95 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC VER 01 3 12 To Our Customer Dear Customer Thank you for choosing this Infrared Camera Please read this user manual carefully before first use Also please keep in a safe place for reference in the future Please operate with the recommended instructions in user manual We reserve the right to change this user manual without further notice AWARNING DO NOT OPEN OR EXCHANGE PARTS REPAIR ONLY CAN BE CONDUCTED BY STUFF NOTICE In order not to cause malfunction or even damage the device please do not direct the lens towards strong high temperature radiation source such as the sun whether the power is on or off Avoid violent shock and impact during operation or transport Storage temperature is between 400C and 600C The device must be kept in original packing case during transport Typical storage place is cool dry ventilated and without strong electromagnetic field Keep the lens surface off grease or any chemical substance which would damage the lens Close the lid after operation Please regularly backup data on PC to prevent potential data loss and format the internal FLASH memory duly to make it operate pr
15. Li 23 50 C 33 85 C 17 80 C Rol 0 95 26 30 C 34 128C 17 66 C lt gt SHX o Emissior Beme Details Typ des Objekts Linie H chste Temperatur 33 85 C Niedrigste Temperatur 0 17 80 C Durchschnittliche Temperatur 23 50 C 2 7 1 Set the color of measured object e Select a measured object in the label list e Click the button to set a color for currently selected object e Select customize a color e Click the OK button to conform the color of measured object 2 7 2 Add remarks for measured object e Select a measured object in the label list e Add Remarks in the Remarks edit box 0 512 characters available e Click the R Upload Current Settings button to add remarks 2 7 3 Change emissivity of measured object e Select a measured object in the label list e Adjust the scroll bar of emissivity 2 7 4 Remove a measured object e Select a measured object in the label list e Click the X button to delete the currently selected object 2 7 5 Add detailed Information in Image remarks 29 If any object in the label is not selected it is available to input information Etikette Name Emission Durchsc H chste T 8 Niedrigste Te Bemerkungen LL 23 50C 33 85 C 17 80 C Ral 0 96 26 30 C 34 12 C 17 66 C a lie Emissior 0 ons Details Typ des Objekts Linie H chste Temperatur 33 85 C Niedrigste Temperatur 00 17 80C Durchschnittliche Temperat
16. On the upper right LCD corner i xx displays the spot measurement result For better accuracy long press l button to perform manual rectify Select Area Rect Measurement to measure max min and average temperature within a rectangle box It is recommended to press button to freeze thermal image first and then apply different and detailed analysis Press lt button one more time to unfreeze When measure result is outside standard temperature range screen display changes to indicate either below or above temperature range E g 175 395 is with 20 250 C then the Camera Will Display gt 250 0 C or lt 20 0 C to Prompt Users 4 4 Infrared Image and Voice Annotation Each thermal image can save up to 40 seconds voice annotation data Image and voice annotation can later be reviewed on PC by bundled IRSee software To save infrared image press the Shutter button while accessing the target image then a Voice dialog box appears select Cancel then press the Enter key the image file has been saved select the Record then press the Enter key both image and voice files have been saved In main menu press the Enter key to File gt Save provides the same function _ Select Cancel during voice recording to exit 4 5 Infrared Image Playback Press the Enter button to enter the main menu Select the Main Menu File Manage and then select the file directory and file name the thumbnail image
17. Ratio Due to long time usage of device the sensitivity of IR detector may decrease In such case it is necessary to adjust ratio value to get more accurate temperature reading During calibration if temperature reading is higher than actual target temperature change ratio value lower and vise versa Press or once to change ratio value 0 01 Long press lt or gt will change ratio value in 0 1 intervals Adjust Temp Under certain condition it is necessary to adjust temperature reading by a 25 pre define value Normally this option should be left unchanged Press lt or once to change 0 10 Long press or gt will change this value in 10 interval Save Setting All parameter changes must be saved before power off device Otherwise changes will not be saved for next power on 5 2 3 Image There are 5 items Image Setup Analysis Setup Image Reverse Clear Screen and L amp S Auto Manual in Image Menu r Infrared 250 IN USB1 114 11 11 1435 10 ag T a Image sub menu Image Setup 26 mre eb WA ed Image Setup Sub menu Alarm Switch Press or turns on or off the alarm function If the Alarm Switch is on when target subject within area box has surface temperature over Alarm Temp device will alarm with buzzer sound and mark the high temperature location as Alarm Color if Alarm Color is set Alarm Temp When Alarm Switch is off this option is disabled When Alarm Switch is o
18. area 32
19. ce feature Display Device Select between LCD display and external monitor device Only one video output device can be selected at one time the other one will be disabled EO If accidentally selected external monitor device and LCD display is disabled power off and power on device to get LCD display back Screen Save Set the number of minutes without operation to trigger disabling LCD display to save power Select between 5min 10min 30min and None Power Save Set the number of minutes without operation to trigger power off completely Select between 10min 20min 30min and None USB File Transmission and Video Transmission press lt or gt button to switch options If select File transmission device is used as a U disk to export delete or format the data saved on the built in FLASH or SD card to PC If select Video device is used to transmit the real time video images to PC via IRSee software After set up IRSee Report Suite and USB device condition to video mode the USB device can be used as a camera for infrared and visible light For example click the video connection key and after a while the video conversation will be achieved via MSN Skype QQ etc when the video source is only from Thermal Imaging Camera If the sources are two or more please choose TIUSB among device names and the device names can pop up after pressed video connection key Storage Medium Storage Medium includes Internal a
20. ctual number of corresponding measured points It is available to click the button to switch 2 4 2 Gradient Solid Color Display If the gradient histogram display mode is enabled the system can automatically select corresponding color to fill the histogram in accordance with the temperature If the solid color display mode is enabled the system will fill histogram with red it is available to click the button to switch 2 4 3 Enable Disenable Grid If the grid is enabled it is available to draw grid dashed lines on the histogram background if disenabled it s unavailable to draw it is available to click the EE button to switch 2 4 4 Save a Histogram Click the Eisave Images button to pop up the file selection dialog box Select the image format Check set the path to save the image Click the Save button to save the current histogram 2 4 5 Set the Background Color Click the o Background Color button to pop up color selection dialog box Select a background color Click the OK button to confirm the background color 2 4 6 Show Hide the Out of Range Column Click the button to show or hide any column out of temperature range of color code bar composed of points 25 2 4 7 Reset Click the bad Reset button to reload the default state to the histogram 2 5 Line Profile Measurement Area nme H chste Temperatur 33 85 C Niedrigste Temperatur 17 80 C Durchschnittliche Temperatur
21. d Right 2 buttons to resize horizontal fusion area Select and set thermal superposing temperature range in thermal superposing imaging mode press Up 4 and Down w buttons to select slide bar and press the Left O and Right gt keys to set the superposing temperature upper or lower limit as well as the temperature values above or below the superposing temperature Select Color Palette or temperature measurement limit Press Left O and Right gt to change Color Palette and Press Up 4 and Down W buttons to change temperature limit 8 sd Menu Enter button This button has different functions under different conditions 1 In real time Infrared view mode press this button to open the main menu 2 In the menu mode press the key to confirm operation 3 In real time Infrared view mode long press this button to manually rectify measurement result LCD screen will display the word rectifying 4 In image viewing mode long press this button to exit LO After auto rectifying if device has abnormal noise long press sel button to perform manual rectifying usually solves such issues 9 10 Manual Focus T W button Press T W button to manually focus to get better thermal image when auto focus thermal image is not good enough 11 12 CW CCW imaging mode switch Press the button to switch image models among infrared visible fusion superpose and picture in picture P I P 13 Shutter key P
22. e application Place software CD ROM into CD drive and run setup exe in the CD root directory The default route is C Program Files IRSee Report You can change directory when installing Note users who are operating Vista please close user account control to prevent warning Step A Running the Setup exe access the software installation 1 Weke ia Des trv a ath Wu asd han ISa nepar Te stall well mat kali weet al Ste Pao owe pa camaae NG omma chet Met Step B Click the Next button the system indicates the installation path please adjust or change as needed hete Dramaban on teen KA EE ENE EF LA Tang rd mad Ian Papa o te amang Na Te recta tm Mo kn oh Moed Tag wal ie n wed ia O heer a med ote hier Step C Click the Next button continuously until the software installation is completed The system will enter the encoder installation automatically Step D Click and follow the default installation settings until the installation is completed fe Setup ffdshow Completing the ffdshow Setup Wizard Setup has finished installing ffdshow on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup C Run video decoder configuration C Run DXVA video decoder configuration C Run VFW configuration 4 Uninstall Software Please select the Delete button if want to reinstall the software 5 Starting up Software The following icon appears on Windows de
23. e ee ee Ge 21 Horizontal Line Measure 21 Vertical Line Measure sesse see 22 Area Rect Measure uu 23 Parameters anan 24 EMISSIVIIY SESSE SE aan 25 DISTANCE RE a aaa N 25 AdjustRatiO a ES EE EE ation deeds 25 Adjust TOMP esse sesse se eke ee Ge Ee ke 25 Save Selde ee a 26 b 2 8 IMa des EES DE Ee Ee tates ee ee EE De Dee ie eed 26 IMAGE SelUP SE EE ENS 26 Alarm Switch una 27 Alarm Temp nestane ete ke 27 Alarm COIOF ee ee ee Re Re Re 27 Isotherm Color on eceececseeteeseeeeeseteeeesees 27 Isotherm Temp i iese sesse se ee se Re ke Ge ee 27 Hot SuperpositiON eesse sesse ese sk se ee 28 Thermal Superposition Attribute 29 FUSIONS sed Renee NAK ee ee Re ee de eed 30 Alarm Color si ESE is ERGE GE Ee Ee 33 Analysis Setup ME Re Nee Se ee 33 Temp Range sees ese se ee ee se Re ke 34 IR LENS Anal onda toned nad 34 Ambient Tempe sesse sesse se se ee ee 34 Reference see Re Re RA ee Re 35 Ref Temps decent ies ES es Ee Sek Re 35 Image Reverse esse se se se ee se Re Ge ee Ge ee 35 Clear Screen u s 35 L amp S Auto Manual Mode asana 35 5 2A SETUP Sen EER sateen GE OG EG ED 35 System Setup ees ee Re Re Re ee 36 Language sesse se sesse se ee Se GR Se ee Se ee 36 Auto RECTIFY ese sesse ee ee ee ee 36 KUTO SANGA ocean eines EE RE GE EED 36 el EE EE PAT 36 TransparenCe i sesse sesse see se Re se ee 37 Display Device
24. guages available namely Chinese simplified amp traditional English Italian Japanese Russian French German Korean Spanish and Measure Portuguese Emissivity Rectification Adjustable from 0 01 to 1 0 Ambient Temp Auto according to background Rectification temperature input ae re Auto according to distance relative Correction humidity ambient temperature input Dew point Available only for 170 and 390 alarm Storage Media 175 Up to over 700 images Built in Memory 395 Up to over 500 images A 175 Up to over 5600 images 2G Micro SD i 395 Up to over 4000 images Storage Storage Mode Auto Manual single frame image storage File Type JPEG with 14 bits measure data i 40 Seconds voice recording voice Annotation per image built in microphone USB USB File download video transmission Laser Director Class 2 1mW 635nm Red Battery Type Rechargeable Li lon Battery Battery Operating 3 Hours Under normal temperature Power Time Supply Charging type Intelligent charger Power Save Included External Power 5V 5 DC Operating Operation DAT 3 Condition Temperature eve Storage NG Temperature EE ee 44 Humidity lt 90 non condensing Protection Grade IP50 Weight 480g Physical o OWH 128x62x154mm 8 Technical Support For common mistakes and issues during operation please refer the following form If is
25. ine t Naa na maa de MEE SIT sonnoh lampa shana O E mia ske amns dana SEEC nand ole ed celine miin salem n Remark 13 NO File Date Measuring Time 8 P155218 JPG 2011 11 22 15 52 18 Et UERSS SUNY se Emissivity 0 96 Remark pir 1780c 2380c 2922c k R1 oes 1663c 1839c 3412c Histogram Profile line EE teh kahapon aterm EE EE Bae wt sz sg 14 2 2 5 2 Edit Report If a report is to be closed the system will prompt whether to save the report or not AA The report is being edited out save the report Cancel Click the OK button Savein Desktop Mosa my Documents 4 My Computer My Recent My Network Places Documents 9 19 Dist IEIR Analysis Software OIRSee Report Moor Tom11t009 O MyDrivers E photo THEO CJUv5ee Report Desktop My Documents My Computer File name My Network Sawaastype F Input and select the saving path and file name and then click the Save button Click the report in Ribbon gt gt Edit Report see 9 Dekon A My Documents 9 My Computer MyRecent My Network Places Documents 38 19 Disk1 CDIR Analysis Software CDIRSee Report Moor Com111009 CDMyorivers photo TED 2UvSee Report Desktop My Documents My Computer File name My Network Saveasiype HY Select a saved report to reopen and edit it
26. is the same as Shutter button Record amp Play The Voice menu is used for recording playing back save and cancel operations The J icon indicates voice annotation data with current thermal image If voice annotation already exists press Record will record new voice annotation and erase previously saved one Press Cancel first to stop recording then press Save to save 17 kid lht d BG AWIN Record Play Save Canca Voice Annotation Delete Enter the delete menu a dialog box pops up prompt select the Ok option and press the Enter key to delete the thermal image Infrared sy OD Delete saved thermal image Long press the Enter key to exit the preview mode Format Format the built in FLASH or SD card When Press Enter button to Main Menu Setup System Setup Storage Medium to select the Internal then format the built in FLASH to select the SD to format the SD card After the option is selected a dialog box pops up prompt whether to format the disk press the Ok option to immediately format saved data press Cancel option to exit 18 Format saved thermal image 4 Once FLASH or SD card is formatted all saved data will be permanently deleted please ensure that the data has been transferred to PC before format CO Ifthe system fails to save images please search and kill viruses and if no virus is found please backup data before formatting
27. left click to select Drag the mouse to the required temperature value position Method 2 Click the scroll bar on the arrow button to adjust upper and lower temperature each step is 0 1 27 2 6 3 Adjust upper and lower limits of isothermal color If the isothermal color is enabled a user can adjust the isothermal scope Method 1 Move the mouse to ne upper and lower temperature on right side of the color bar When the mouse s status turns please left click to select Drag the mouse to the required temperature value position Method 2 Click the scroll bar on the arrow button to adjust upper and lower limits each step is 0 1 2 6 4 Select a dew point When a dew point is selected all points which temperature is below the dew point will be colored in uniform 2 6 5 Set isothermal color and dew point color The default isothermal color is fluorescent green the default dew point color is blue and the dew point is prior selected Click the P Set Color button to pop up the color selection dialog box e Select customize the background color eClick the OK button to confirm the selected color 2 7 Label Area The Label Area indicates detailed information of measured objects when the measured object changes the object s label will change accordingly the structure of label area is as below 28 Etikete Name Emission Durchsc H chste T Niedrigste Te Bemerkungen
28. measure press 4 and button to adjust sampling line position and press lt and gt button to adjust cursor line position Press Enter button to enter Attribute Menu After 2 seconds with no operation system will exit to real time Infrared view screen 21 Attribute Horizontal Line Measure Attribute Vertical Line Measure Vertical Line Measure Vertical line is temperature sampling line and upper right LCD corner displays temperature measurement reading on horizontal cursor line intersection After using HotKey button 2 select line measure press lt and 3 button to adjust sampling line position and press 4 and ww button to adjust cursor line position Press Enter button to enter Attribute Menu After 2 seconds with no operation system will exit to real time Infrared view screen 22 7 11 09 05 4 09 27 21 Vertical Line Measure Attribute Area Rect Measure Press and button to select or deselect Selected Area is check marked Up to 3 areas can be selected Area Rect Measure Measure result on upper right LCD corner is the temperature 23 measurement result within the corresponding rectangle There are 3 measure types max min and average temperature Area Rect Measure Attribute Press the HotKey button 2 until area rectangle is flashing in yellow Press Enter button to enter Attribute Menu in which four parameters can be adjusted namely emissivity set reference measure type m
29. measuring area are shown below ila ger 1emperaturmessung HEaaoxKd The measurement objects can analyze the thermal images by the following three kinds of analysis methods point line and area 17 Line measurement analysis has three arbitrary line horizontal line vertical line and multiple line analysis is also available Area measurement analysis has below rectangular elliptical and polygonal analysis The system can analyze up to 20 spots objects a line analysis object 20 area analysis objects 10 polygonal objects and 10 elliptical objects simultaneously 2 3 1 Select Measured Objects The prior sequence of object selection is point line and area e When two or more objects are simultaneously selected the system can operate in accordance with the above prioritization e g if both a point object and a line object are simultaneously selected the point is more prior than line the point object will be prior selected If both an area object and a line object are simultaneously selected the line is more prior than the area the line object will be prior selected e ftwo or more areas are simultaneously selected the smaller area will prevail e g If Rectangle 1 and Rectangle 2 are simultaneously selected Rectangle 1 is smaller than Rectangle 2 Rectangle 1 will prevail 2 3 2 Point Analysis Create a point Click the Create button Move the mouse to a point to be analyzed and click it
30. mperature 39 Continued Parameters List of Default setti ng Items Parameters _Value function Languages English Automatic correction 150S Automatic storage 0s Video format PAL System Settings Menu Transparency Enabled Display Mode Screen Screen Auto close None USB File transmission mode storage media Flash Time Settings Time No change System Information Select to display system information such as serial number software version and production date etc Disc Information Select to display Disc Information as follows the dialog box can indicate the FLASH s used disc space and free space as well as used space free space of SD card 40 Disc Information 6 Building Thermal Imaging Summary As the quality of life improves and the low carbon life style becomes known higher demands are being set on buildings The features of our TI series IR camera make it possible to detect slight temperature difference and to analyze indoor humidity and leakage Hereinafter are images in Some cases Infrared The effect drawing of indoor humidity 41 42 The effect drawing of indoor pipe heat leakage Infrared a o 16 The effect drawing of indoor corner air leakage 7 Technical Specifications Continued Technical specifications
31. n Alarm Temp is the desired alarm temperature Press lt or once to change Alarm Temp 0 10 Long press or gt wil change Alarm Temp in 10 interval Default setting is 37 00 Alarm Color Alarm Color can select as Auto Black White Red Orange Yellow Green Blue Gray and Purple Default setting is Auto which is no color alarm Isotherm Color When this option is Auto there is no Isothermal display Otherwise target subject Infrared image will change to selected color when temperature is within the range of Isothermal Temp Isothermal Width 2 Default setting is Auto Isotherm Temp 27 Press or 2 once to change Isothermal Temp 0 10 Long press or gt will change Isothermal Temp in 10 interval Isotherm Width Adjust Isothermal Width to change the range of Isothermal Color display Press or 2 once to change Isothermal Width 0 11 Long press lt or gt will change Isothermal Width in 10 interval Default setting is 1 00 Hot Superposition Overlay infrared image partly on visual image which is convenient to identify and analyze infrared image There are 3 modes to setup target area to infrared image the other area to visual image Press or button to select Above Below Interval of thermal superposition Interval If select Interval type it is necessary to set the upper limit of interval and lower limit of interval Press lt or gt to change 0 11 Long press or gt
32. nd SD card press Cor gt button to switch options The capacity of Built in FLASH is 256M the capacity of 37 standard SD card is 2G and the disk format is FAT Device only identify FAT format SD card not any other format Time amp Date Set system date and time Press 4 or w button to select an item press Cor gt button to change its value and press Enter button to confirm If Li lon battery is removed for a long time it is necessary to reset system time and date IN USBI 11 11 11 1606 12 Time Setting Factory Default Restore factory default and rectify some improper settings 38 Parameters List of Default settings Items Parameters Value function Spot1 2 3 4 Disenabled area1 2 Disenabled Measured Target 9 area 3 enabled Measuring line None Emissivity 0 96 Distance 1 5 Measurement Humidity 60 Parameters Correction factor 1 00 Correction 0 0 C temperature Alarm Disenabled Alarm temperature 37 0 C Alarm color Auto isothermal color etc l Isothermal 37 0 C Image Settings temperature Isothermal height 10 C Thermal Interval superposition type Fusion Auto Dew point alarm Disenabled Temperature range 170 390 20 100 C 175 395 20 250 C 11mm 170 175 Lens 21 5mm 390 395 a ro Analysis Settings Temperature unit C Ambient temperature Manual male sine Disenabled measurement Reference 30 0 C te
33. ns out fast Ambient temperature is too low or too high The rechargeable battery is not fully charged Recharge the rechargeable battery The life of battery is almost over about 300 cycles of charge and discharge for the type of battery 2 Replace rechargeable battery ey ino thermal image displayed Lens cap is not open open the lens cap thermal image turns black amp white o Check if black and white color code is selected reload default settings 46 9 For reference purpose only Appendix Emissivity of Raw Material Material Surface Temp C Emissivity 2 Aluminum inoxidized 100 0 20 Oxidized 100 0 55 Brown polished 20 0 40 Brass Unpolished 38 0 22 Oxidized 100 0 61 Copper Oxidized badly 20 0 78 Oxidized 100 0 74 Iron Rusted 25 0 65 Cast iron Oxidized 200 0 64 inoxidized 100 0 21 Wrought Rough 25 0 94 Iron Polished 38 0 28 Nickel Oxidized 200 0 37 aa Oxidized 60 0 85 Steel 800 Oxidized 200 0 79 Brick 20 0 93 Concrete 20 0 92 Glass Smooth flat 20 0 94 White 100 0 92 Lacquer Natural Black 100 0 97 Smoky black 25 0 95 Carbon Candle smoke 20 0 95 Black lead rough 20 0 98 Paint 16 Color average 100 0 94 Paper White 20 0 93 Soil 20 0 90 Wood Polished 30 0 90 Water 30 0 96 Skin Human 32 0 98 Fine 21 0 90 china Rough 21 0 93 47
34. of the stored image is displayed then press the Enter button to enter the viewing state When viewing thermal image press the Left O or Right 2 button to switch thermal image in the same folder 10 The J icon indicates voice annotation attached to current thermal image Press Enter button to enter File Voice then select Play to play back Long press the Enter button to return the real time imaging mode 4 6 Telephoto and Wide angle lens The device can be equipped with telephoto lens or wide angle lens Put lens in accord with the dots Figure 1 in line then turn lens in clockwise direction till to the two dots in line Figure 2 The dot on the lens The dot on the device front part Figure 1 The dot on the lens The dot on the device body Figure 2 Enter Image Analysis Setting IR Lens menu press the lt or button to adjust the corresponding lens 11 Operate Image Save and Image Playback according to the steps mentioned in 4 4 and 4 5 here in above 4 7 Connect to PC Connect device to PC using included USB cable it s available to to export delete and format the data saved in the built in FLASH memory or on the SD card 4 8 Video and Audio output Insert Converter cable to Multifunctional interface for audio output or video output connect Monitor to Converter cable using Video cable Enter Setup System Setup Display Device Press the Left 0
35. oolbar to pop up the customizing dialog box Left click the Customize button to pop up the Customize Keyboard dialog box Select a type on the upper left type edit box Select a button on the upper right command edit box Set the button shortcuts in the following two Edit Boxes and drop down menu Press the Assign button to save the settings 2 1 3 Position Adjustment of Quick Access Toolbar Right click the Ribbon to pop up a menu Left click the Ribbon Quick Access Toolbar Below and adjust its position 2 2 Ribbon The Ribbon is composed of File Parameters Audio Temperature Type Settings Report Wizard USB and Panel The property analysis interface consists of File Color Parameter Audio and Settings as shown below are P155218 ae ye Report Edt Navigation Report Re dT se LE DA Open Save Settings Windows Return to default setting j Emiss 96 ji ee Humidity 60 a 9 F Abient 2 7 K J Use 2 2 1 File 2 2 1 1 Open Click the File button to pop up a file selection dialog box Select and open a file to be analyzed in the dialog box 2 2 1 2 Save Method 1 Click the Save As F button to pop up a file selection dialog box Set select the file path name where the file is saved Save the image in the current active window Method 2 e Click the File and select the Mi Save All b
36. operly Table of Contents 1 Product SUMMaNy sissies eke ees ee SR kke 1 1 1 Standard ltem LUISA AGE 1 1 2 Optional hem let eN GER GENE Ge 2 2 Battery and Charger iese se se se ee ee se Ge Ge Re ee 2 2 1 Charging Battery SE Gm ee 3 2 2 Direct ChardINg paa Ge reses ee SEE Gee KG 3 2 3 Attention for Using Battery Charger 3 3 Panel Function Summary ul 1 sesse see ee se ee Re ee 3 3 1 Main Control Panel ee ese ie ee GE ee 4 3 2 Side VIEW ESE AA Se ge Re 7 3 3 Bottom VIEW ese see see se Re Re Ge Re Ge Re Re Ge ee 8 3 4 Left Side VIEW ESE GE EE Ge N 8 4 Quick Start Reference se ee ee Re ee 9 4 1 Battery Selling sisie esse Ee seek ke Ee Ee 9 4 2 Quick Operations ER Ge ke ee ed 9 4 3 Measure Target Temperature sesse sesse sesse 10 4 4 Infrared Image and Voice Annotation 10 4 5 Infrared Image Playback sesse se see see se ee 10 4 6 Telephoto and Wide angle lens 11 4 7 Connect to PO esse se Eed eN oek 12 4 8 Video and Audio OUTPUT sesse sesse ee ee Ge ee 12 5 Operation MENU ee ee ee Re Re Re ee 12 5 1 Display SUIER Gis Dae Reeds es GR 12 5 2 Main MENU sees ee se ee Ge Re Re Re Ge Ge Re Re Ge ee 14 EA EE ER EE EN 16 MELT EE OE NE N 16 Si EE 17 Record amp Play si ME ES ee ee ee 17 Delete sis ese NANA Rg ee Ee se eN 18 ai EE EE N 18 5 22 Measure ii kels EL ER ges ee Se ee Ee 19 sed Es SUE N 19 Line Measure iese see se ee ee S
37. ove size Infrared Attribute 31 IN USB1 114 11 11 14 27 25 Lo 31 Area Rect Measure Attribute Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current area as reference If selected all measure result will be relative value to this temperature Measure Type Select from max min and average Adjust Adjust rectangle position and size Parameters Change different settings to adjust temperature measurement accuracy Press and ww button to select different parameters and press lt and button to change value 24 N KEN NI a IN j USBI TT 14 29 22 a EE Parameter Sub menu Emissivity Emissivity varies based on target subject material surface temperature surface roughness measurement angle and etc Press lt or 2 once to change Emissivity by 0 01 Long press lt or gt will change Emissivity in 0 1 intervals Distance This value can be omitted if target subject is close to device less than 10m Otherwise set Distance value accordingly to get more accurate temperature reading Press or gt once to change Distance 0 1m Long press or gt will change Distance in 1m interval Humidity This value can be omitted if target is close to device less than 10m Otherwise set Humidity value according to environmental condition Press or 2 once to change Humidity 1 Long press or gt will change Humidity in 10 interval Adjust
38. pop up a file selection dialog box Select a file path and save the image in the current active window Method 3 Click the software icon on the top left corner Click the Save button to save the modified image on the current active window Method 4 Click the property analysis in Ribbon Click the Save button to save the modified image on the current active window 2 Modules As displayed on the software interface the software has the follows the Quick Access Toolbar Ribbon Measuring Temperature Zone Histogram Area Line Profile Measurement Area Color Code Area Label Area and Visible Area 2 1 Quick Access Toolbar Operate the Quick Access Toolbar to customize the buttons in the Ribbon and the file system the buttons function is consistent with the buttons shown in corresponding areas Customize Quick Access Toolbar New N Open O Save S More Commands Show Below the Ribbon Minimize the Ribbon 2 1 1 Customizing the Quick Access Toolbar Right click the Ribbon to pop up a menu Click the Customize Quick Access Toolbar to pop up customizing dialog box Select the area name in the command drop down box Select your required buttons from the left box and create to the right box Itis also available to remove buttons on the right editing box 2 1 2 Customizing Buttons Right click the Ribbon to pop up a menu 6 Left click Click the Customize Quick Access T
39. port for further analyze Click the Report Wizard to select the type of exported report as needed f Report Navigation ferns ETIESE ENE EE SEER Er templet style Standard style system Architecture style system Industry style system Power templates system Click Next to select an image or multiple images ETTER NO Infrared mage Actual maga File name P144956 JPG PI53133 1PG Iy RE Fie name P144955 1FG P153133 PG P1552186 FG Cancel Freviousstep Newstep preview Fill in related information in accordance with different types of report templates Preview 10 Company Address TelFax Contact Device name Device series Measuring object name Position of measuring point Measurement task Inspection Report Client Address TeliFax E mall Contact Device mode Lens 12 NO File Date Measuring Time 1 P144956 JPG 2011 11 13 14 49 57 Emissivity 0 96 Remark tif 202c sere msec LET 0 96 1843c 21780 7178C NG gt wine Histogram Profile line firn uat SES spadna ahit SEOSE aa aya aar aa MACE x x a v we m A x oa 8 Ng PI NG n ba k NO File Date Measuring Time 2 P153133 JPG 2011 11 14 15 31 33 yass juua Emissivity 0 96 Remark t eoe 2863c ese o ooo U Rot 096 1706c mm Histogram Profile l
40. ress the button to save the current image 3 2 Side View gs 14 Power ON OFF button Long press this button to power on off the device 15 Multifunctional interface for audio output or video output Please insert converter cable It can be connected to headphones to listen the playback audio notes as analog audio output interface It can be connected to the monitor to play videos as a video output interface 16 SD card interface MICRO 2G SD card can be inserted into the interface to expand storage volume 17 USB Interface Standard USB interface can be connected to the computer for data transmission 3 3 Bottom View 18 19 18 External DC In External DC requirement is DC 5V 19 Screw nut on tripod Size of screw nut on tripod 1 4 20 3 4 Left Side View 20 3 2 Color 270 tiltable LCD 4 Quick Start Reference 4 1 Battery Setting Insert and move in the lithium battery as indicated direction user can easily insert and move the battery f Battery Installation Battery Removal 4 2 Quick Operations Insert the battery correctly Long press Power button until the LED light is on and wait until system finishes initialization Slide IR Lens lid down point to target and adjust focus to get crisp thermal image Long press the sd button to rectify thermal image 4 3 Measure Target Temperature Point device to measurement target and press HotKey button 1 to auto focus
41. roportion press Cor gt to set Auto 1 2 1 4 3 4 mode Adjust select Size to confirm press 4 W lt gt buttons to adjust fusion box s size select Position to confirm press 4 W lt gt buttons to adjust fusion box s position After 2 seconds with no operation system will exit to real time Infrared view screen Dew point alarm available only for 170 390 32 Dew point alarm press or gt button to turn on off dew point alarm function If the Alarm Switch is on manually adjust the current ambient temperature and humidity the corresponding dew point temperature can be indicated on the lower left corner of screen if the dew point temperature value exceeds the preset temperature device will alarm with setting alarm color Alarm Color Alarm Color can select as Auto Black White Red Orange Yellow Green Blue Gray and Purple Default setting is Auto which is no color alarm Dew point temperature shown on lower left corner CO dew point temperature can be defined as a temperature of air cooled to saturation in the case that both the water vapor content and pressure in air are consistent which is related to ambient temperature and humidity Analysis Setup 33 Analysis Setup Sub menu Temp Range Select Temp range base on measure target temperature 175 395 standard Temp range is 20 C to 250 C extra temp range 200 C 600 C or temp range 200 C 1200 C is customized service 17
42. sesse se se se Re Re Ge ee 37 Screen Save u s 37 Power Save ee ee ee ee ee ee 37 Storage Medium ee ee ee Re RR ee Re Re 37 Time amp Date esse se RR ee Re RA ee ee 38 Factory Default iese see se ee se Re Re Ge ee 38 System Information 40 Disc Information sesse se ee Re Re 40 6 Building Thermal Imaging Summary 41 7 Technical Specifications 1 7 43 8 Technical Support sees se se ske Ge Ge RR ee Ge Ge 45 iii iv uP Product Summary The Infrared Camera equipped with Uncooled Focal Plane Array Micro bolometer produces crisp thermal image and accurate temperature reading to help increase system maintenance quality and efficiency in many industries The Infrared Camera is packed with advance features such as colored thermal images multi measurement methods real time video voice annotation sound and color alarm IR fusion Built in flash and SD card storages Typical Application Power Industry Monitor and diagnose the condition of electrical wire and equipment detect power leak and prevent system malfunction Petrochemical Industry oil pipeline check material interface detect heat leakage insulation structure and power equipment detect Fire Protection forest fire protection and latent fire source search self ignition prevention and detection of special material electric fire precaution detect Medical Application Accurately meas
43. sktop after installing IRSee software Double click the icon and startup IRSee interface Open an image by menu open or icon B in the ribbon Pu SeEGhe w ET n WE DEE RE BEE ST gt 2 PET TH oa so p Note IRSee software has 10 different working languages namely Chinese simplified amp traditional English Italian Japanese Russian French German Korean Spanish and Portuguese IRSee software has auto recognition language function with the operating system in PC the IRSee will be in English version the operating system is beyond mentioned languages in PC Il Function Description Image Import and Export 1 1 Image Import Method 1 Click the software icon on upper left corner to pop up the menu Click the Open button also available to select a recently opened image path in the image bar to pop up the file selection dialog box Select a file in the file selection dialog box single or multiple selections available Method 2 Click the Open button in the ribbon 1 2 Image Export It is available to export in accordance with the following methods after importing images Method 1 Click the Save As button on the software icon on the upper left corner to pop up a file selection dialog box Select a file path and save the image in the current active window Method 2 Click the property analysis in toolbar Click the Save As button to
44. sue cannot be resolved please contact our technical support department For simple problems arising during operation please refer to the following table If the problem cannot be settled please cut off the power and contact our technical department Problem Cause and Solution No battery or batteries are not installed correctly Install battery correctly Camera cannot be Battery power is used up powered on Change battery or recharge Save power mode power on after 5 seconds Device power off Battery power is used up automatically Change battery Ambient temperature is too high or low Battery is not fully charged recharge battery fully Battery may already reach end of life 300 usage cycles use new battery to charge Battery power is soon used up Lens lid is closed No thermal image Remove lens lid Thermal image is black and white Black amp white palette may be selected restore factory default 45 Failures Causes and Solutions The infrared camera can not start O The battery is uninstalled or improperly installed 2 Insert the battery or re install the battery The battery runs out 2 Replace or charge the battery infrared camera auto shutdown 2 Wait 5 seconds and then restart The infrared camera shuts down automatically The battery runs out 2 Replace the battery Battery power ru
45. t vertexes JL When the state of mouse becomes click to select it Move the mouse to change the size of the ellipse Delete an ellipse Select the ellipse to be deleted Click the xi button to delete the current temperature measurement object 2 3 5 Save Images Click the B Save Images button to pop up the file selection dialog box Select image formats Select set the file path Click the Save button to save the image the image does not contain any measured temperature data and is unavailable to be analyzed by software 2 3 6 Clear measured objects 23 Click the Q Clear Measured Objects button to clear all point line area analysis of measured targets 2 3 7 Fusion Infrared Click the ja button to switch between the fusion and infrared modes 2 3 8 Export Temperature Data Click the button to export all the points temperature in the whole thermal image to TXT file the temperature unit is Celsius 2 3 9 Audio The m option is an audio option under Temperature image module the selected iron indicates the image consists of playable audio the unselected iron indicates the image doesn t consist of any playable audio 2 4 Histogram Area Histogramm BEBE we 2 4 1 Relative absolute Scale If the relative scale is selected the vertical axis represents the percentage of the number of measured points if the absolute scale is selected the 24 vertical axis represents the a
46. to change in 10 interval Infrared image overlays visual image between two specified temperature Above if select Above type it shall adjust above temperature level Press or 2 to change 0 10 Long press Cor to change in 10 interval Infrared image overlays visual image above specified temperature 28 Below If select Below type it shall adjust below temperature level Press or gt to change 0 10 Long press Cor to change in 10 interval Infrared image overlays visual image below specified temperature Thermal Superposition Attribute In Superpose mode Press Hotkey button 2 the interval area is flashing in yellow then press Enter button to pop up dialog box it is available to adjust Superposition Type Upper limit of interval Lower limit of interval Above temperature Below temperature 29 Thermal Superposition Attribute Fusion Scaling infrared image overlaying visual image the fusion has 4 types automatic 1 2 Fusion 1 4 Fusion and 3 4 Fusion e a automatic 30 1 2 fusion 1 4 fusion 3 4 fusion 31 Fusion Attribute Under thermal fusion mode press Hotkey button 2 to switch until the word Fusion is flashing in yellow then Press Enter button to pop up dialog box to set Fusion Mixing Ratio Position Size After 2 seconds with no operation system will exit to real time Infrared view screen Fusion Attribute Mixing p
47. ur 23 50 C 2 8 Visible Light Sichbares Licht ELE 2 8 1 Open an Image This feature is available for any image that without visible light e Click the kam Open button to pop up the file selection dialog box e Select a file to be added from the dialog box 2 8 2 Save an image e Click the Pi save button to pop up the file selection dialog box e Select an image format e Check set the path where the image is saved e Save the visible light image 2 8 3 Delete an image 30 This feature is available for any image that without visible light Click the I Delete button to delete the currently added visible image 2 8 4 Flip an image This feature is available for any image that without visible light at A or button to flip an image clockwise or counterclockwise Sichtbares Licht eax Pra Click the 2 8 5 Fusion This feature is available for any image that with visible light Va Click the button to set an image e Set the transparency 31 Drag the lower left progress bar to adjust the fusion values between infrared image and visible image e Set infrared display range Drag the right two progress bars to adjust the infrared display range of interval or above upper or below lower limit Infrarot Anzeigebereich einstellen C zwischen O auBerhab i gt LI 600 0 200 0 Click the OK button to save the file the updated image is displayed on the measurement
48. ure human body temperature and analyze temperature field distribution Building Industry humidity air leakage and insulation defects detect Other Applications Civil engineering scientific research and railway etc 1 1 Standard Item List The infrared camera comes with the following standard items and accessories Name Quantity Infrared Camera 1 SET Li lon Battery 2PCS Charger 1 PC SD Card 1 PC SD Card Reader 1 PC USB Cable 1 PC Video Cable 1 PC Converter cable 1 pc User Manual 1 PC IRSee Software CD 1 PC Adapter 1 PC Transport Case 1 PC 1 2 Optional Item List Wide angle lens Telephoto lens 2 Battery and Charger It is recommended to charge battery immediately when device indicates low power please read more about battery installation and removal methods on Page 8 Device comes with two sets of Li lon battery and one battery charger It is strongly recommended to operate only with the included battery and charger Use any other brand charger or Li lon battery may cause fire or critical damage 2 1 Charging Battery Align the notch of the battery at the charger s mount press the battery downward gently along the triangular arrow and fit it to the end Connect the charger to an AC outlet during charging the red LED will be on and when charging is completed the green LED will be on instead EO It is about 4 hour s to completely charge one battery
49. use becomes left click to select the line Move the mouse to the position of starting point terminal point to be moved When the state of mouse becomes left click to select starting point terminal point Drag the mouse to the required position of starting point terminal point Delete a line Select the line measurement object to be deleted Click the xi button to delete the current temperature measurement object 2 3 4 Area Analysis It has three areas rectangle polygon and ellipse Create a rectangle eClick the Borste Area button to pop up a menu 20 eClick the Rectangle amp eSelect the starting point of the rectangle in the thermal image to be analyzed eDrag the mouse to create a rectangular analysis area Move and Drag a Rectangle Move Move the mouse into the rectangle target area When the state of mouse ER click to select it Move the mouse Zoom in out Move the mouse into the rectangle to be modified When the state of mouse pacomes click to select it Move the mouse to the eight vertexes of the rectangle JL When the state of mouse becomes click to select it Move the mouse to change the size of the rectangle Delete a rectangle eSelect the rectangle object to be deleted eClick the xi button to delete the current temperature measurement object Create a polygon Click the Eloreate Polygon to pop up a menu Click the Polygon of
50. utton to save all the modified images 2 2 2 Set 2 2 2 1 Emissivity adjustment Method 1 Please input a required emissivity value 1 100 in the Emissivity edit box Press the Enter key to confirm it Method 2 Click the Up and Down keys in the edit box to adjust and set an emissivity value 2 2 2 2 Humidity Adjustment ePlease input a required humidity value 1 100 in the humidity edit box ePress the Enter key to confirm 2 2 2 3 Distance Adjustment ePlease input a required distance value 1 100 unit meter in the distance edit box ePress the Enter key to confirm 2 2 2 4 Ambient Temperature Select the option to show the actual ambient temperature while the thermal image is being shot 2 2 2 5 Dew Point Temperature Select the option to show the dew point temperature 2 2 2 6 Cancel Changes Click the Cancel Changes button to recover the emissivity humidity ambient temperature or distance to its original state 2 2 3 Audio The buttons in audio area are available for the measured image consisting of audio information only Operate the option to play back the audio saved in images 2 2 4 Set Temperature Type This option is used to set the temperature display unit click C F or K to set the temperature unit to Celsius Fahrenheit or Kelvin respectively 2 2 5 Report Wizard 2 2 5 1 Report Wizard Report Wizard is used for creating a report the Report Edit is mainly used for editing a re
51. witch between auto and manual rectifying In manual rectifying mode upper left corner of LCD display shows L amp S and press or gt to adjust upper temp limit and lower temp limit 5 2 4 Setup There are 5 items in Setup menu System Setup Time amp Date Factory Default System Information and Disc Information System Setup OS Time ale D i AE AN 4 rag E y T Infor ration Setup Sub menu 35 System Setup There are 10 options in System Setup menu Language Auto Rectify Auto Save Video Transparence Display Device Screen Save Power Save USB and Storage Medium Press 4 and W button to switch selection press and gt button to adjust value active item is highlighted with red background System Setup Sub menu Language There are 11 different language options Simplified Chinese Traditional Chinese English Korean Japanese German French Russian Italian Portuguese and Spanish Auto Rectify Set the number of seconds to perform next auto rectify Set value between 1 and 3000 seconds Value 0 means disabling auto rectify feature Auto Save Set the number of seconds to perform next auto save Set value between 7 to 3600 seconds Value 0 means disabling auto save feature Press lt or once to change the value by 1 second Long press lt or gt will change the value in 10 intervals Video Select between PAL and NTSC 36 Transparence Set to enable or disable menu transparen
52. y 43 140 4_ Image o Setup Main Menu Using 4 or button to select menu item and selected item is highlighted with white background Press Enter or gt button to enter sub menu press lt button to return to the previous menu or exit The lt key is unavailable to switch under a sub menu consisting of left or right switchable options 15 5 2 1 File Using File menu to save playback and delete thermal image or add voice annotation or format disk File Sub menu Manage Select Manage to preview thermal image add or edit voice annotation or delete thermal image File Manage Folder is automatically created if not exist when saving thermal image Folder name is MYYMMDD and YYMMDD is year month and date For example Jan ond 2009 folder is M090102 All thermal images taken in this day is saved in this folder Thermal image file name is Phhmmss and 16 hhmmss is hour minute second according to system time For example P080502 in folder M090102 means the thermal image taken at 8 05 02 time in Jan 2 2009 In File Manage window press 4 and button to select items Press or gt button to switch folder or file when highlighted After selecting thermal image press Enter key to Open to view thermal image or press Enter key to delete it and press Exit to exit File Manage window P164111 1 6 Thermal Image preview Save Save real time thermal image The operation method