ADEMCO 5881EN Series INSTALLATION AND SETUP GUIDE UL
Contents
1. be generated when the receiver s front cover is removed d Affix the receiver s Summary of Connections label to the inside of the housing cover HOLES FOR ANTENNAS AND GROUNDING LUGS CABINET CIRCUIT BOARD l a BOARD P SUPPORTING SLOTS MOUNTING T CLIP RECEIVER CIRCUIT BOARD See Detail D DETAIL A SIDE VIEW OF BOARD SUPPORTING SLOTS CONTROL CIRCUIT BOARD MOUNTING CLIP DETAIL B SIDE VIEW OF MOUNTING CLIP DETAIL C SIDE VIEW ZS OF MOUNTING we CLIP ANTENNA MOUNT 2 PLACES DETAIL D ANTENNA AND GROUNDING LUG INSTALLATION ob AF mount vo Figure 1 Installing the Receiver Board in the Control s Cabinet Setting the DIP switches All Receivers a Set the receiver s DIP switch 2 through 4 to identify the receiver s address refer to the DIP switch chart in the Summary of Connections Diagram on back cover b Verify that DIP switch 1 is in the OFF position c Set DIP switch 5 according to the following chart DIP SWITCH 5 For Set to Commercial Fire Applications ON Non commercial Fire Applications OFF NOTES e If multiple receivers are used on one control DIP switch 5 must be set to the same position on all receivers e DIP switch 5 reduces sensitivity during supervision message reception For commercial fire applications DIP switch 5 must be i
2. the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Finally smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits children playing with matches or arson Depending on the nature of the fire and or location of the smoke detectors the detector even if it operates as anticipated may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death e Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can re
3. 0 C Interface Wiring RED 12VDC input Aux Power GREEN Data Out to Control YELLOW Data In from Control BLACK Ground Range 200ft 60m nominal indoors from wireless transmitters the actual range to be determined with the security system in the Test mode Receiver Sensitivity amp Noise Rejection Receiver sensitivity and noise rejection are dynamically adjusted to match ambient conditions Unacceptably high noise levels or low signal levels are indicated at the control panel For test procedure refer to the Installation amp Setup Guide for the control panel with which this device is used NFPA 72 Compliant TO THE INSTALLER Regular maintenance and inspection at least annually by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts Recommendations must be included for a specific program of frequent testing at least weekly to insure the system s operation at all times WARNING LIMITATIONS OF THIS WIRELESS ALARM SYSTEM While this System is an advanced wireless security system it does not offer guaranteed protection against burglary fire or other emergency Any alarm system whether commercial or residen
4. ATIONS NOTE WHEN CIRCUIT BOARD IS TERMINALS SEE RECEIVER S INSTRUCTIONS MOUNTED IN CONTROL S CABINET GROUNDING LUGS 2 PROVIDED Ma SND seidw MUST BE INSERTED IN LEFT HAND aD Le SaaS EA CH RECENER TERMINALS OF ANTENNA BLOCKS fy h A BLACK MUST BE ON INDIVIDUAL AND SECURED TO CABINET SEE Gs e len senes ES GREEN HOME RUN DIP SWITCH 5 RECEIVER S AND CONTROL S saoiel ON FOR USE IN COMMERCIAL FIRE APPLICATIONS INSTRUCTIONS WHEN BOARD IS aia WIRING SEE THE RECEIVER S INSTRUCTIONS MOUNTED IN A SEPARATE MOUNTING HOLES E OPENING OFF USE IN NON COMMERCIAL FIRE INSTALLATIONS CABINET COMMERCIAL FIRE DIP SWITCH WHITE AREAS SWITCH HANDLES APPLICATION DO NOT USE THE EENG Hii FEGE SOCKET POSITION 2 4 DETERMINE RECEIVER S ADDRESS GROUNDING LUGS FRONT OF PC BOARD CONSULT CONTROL S INSTRUCTIONS FOR ADDRESS TO USE TO RELEASE CIRCUIT BOARD 9 i H 9 DIP SWITCH BELOW SHOWN SET FOR ADDRESS 0 BEND BACK BOTTOM TABS 2 FOR E 2 ZZ e RECEIVER ADDRESS SETTINGS COUN GL FINE APPLICATION akor metoa ONSE EE me OE SUPPLIED WITH INSULATING aii INTERFERENCE SEE ia FRONT AND 775 7 GEETEXT ABOVE WASHERS BENEATH THE HEADS GREEN LED NORMALLY OFF INDICATORLER REAR TAMPER 2 on J J n fon TO MOUNT BOARD IN SEPARATE ONE SHORT FLASH RF MESSAGE DECODED 5881ENHC ONLY i ONE LONGER FLASH COMMAND RECEIVED FROM CONTROL ERUN S FOUR FLASHES ENCRYPTED TRANSMITTER SUCCESSFULLY ENROLLED MUST BE IN OFF POSITION 5881EN SOC V7
5. C STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment FCC CLASS B STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e f using an indoor antenna have a quality outdoor antenna installed e Reorient the receiving antenna until interference is reduced or eliminated e Move the radio or television receiver away from the receiver control e Move the an
6. Honeywell N7635 3V4 11 08 Rev C ADEMCO 5881EN Series RF Receiver INSTALLATION AND SETUP GUIDE INTRODUCTION The 5881EN Series of RF receivers is designed for use with control panels that support an RF receiver connection via the keypad terminals The receiver recognizes alarm status and keypad control messages from wireless transmitters operating at 345MHz One or two individually identified receivers can be employed depending on the control used Connection of multiple receivers to a control can provide redundant coverage or extend coverage in large areas These receivers feature a Spatial Diversity System that virtually eliminates the possibility of nulls and dead spots within the coverage area The 5881EN series of receivers use ADEMCO s High Security technology and can be used in commercial fire installations Additionally the 5881ENHC receiver contains front and back tamper that permits its use in commercial burglary and fire installations For 5881ENHC Receivers e In commercial fire applications the receiver can only be used with control panels that are approved for use in Commercial Fire Installations When the 5881ENHC is used in commercial fire applications DIP switch 5 must be in the ON position e In commercial burglary applications the 5881ENHC can UL only be used with control panels that are approved for use in Commercial Burglary Installations e In commercial fire applications a keypad must be con
7. In both cases avoid mounting the receiver antennas against a metal surface NOTE You may only mount the 5881ENHC its own plastic housing If you attempt to mount the 5881ENHC in the control s cabinet the receiver constantly reports a tamper condition 1 Remove the receiver s cover by inserting a screwdriver blade in the slot at the center of the cover s lower edge 2 If the receiver is to be mounted within the control s cabinet refer to Figure 1 a Remove the receiver s circuit board from its base by bending back the two flexible plastic tabs that hold the board s lower edge b In the control s cabinet unfasten and move the control circuit board downward if already installed c Hang two mounting clips provided with the receiver on the raised cabinet tabs as shown in Detail B of Figure 1 d Insert the top of the receiver board between the rows of slots at the top of the cabinet as shown in Detail A e Position the base of the receiver board onto the mounting clips and secure to the cabinet with the supplied screws See Detail B f Hang two mounting clips supplied with the control board on the raised cabinet tabs as shown in Detail C in Figure 1 g Insert the top of the control board into the slots of the mounting clips secured in step e above h Position the lower end of the control board into place on the mounting clips and secure both to the cabinet with the two supplied screws i Insert both groundin
8. Summary of Connections Diagram For the latest warranty information please go to http www security honeywell com hsc resources wa Honeywell 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2009 Honeywell International Inc www security honeywell com N7635 3V4 11 08 Rev C
9. and Fig 2 2 Thread the ECP wire through the conduit and feed through the opening at the side of the box rear 3 Remove the circuit board from the 5881EN case and discard case Install the circuit board into the 5800BOX and secure using the 4 screws provided Install each antenna refer to Installation Step 6 4 Connect the ECP terminals as shown 5 Insert slots on top of box cover into hinges on top of box back and secure using 2 cover securing screws 5800 SERIES CONTROL WIRELESS PANEL TRANSMITTERS EGP TO BURGLARY DEVICES Fa isolator e j KEYPAD 2 WAY TERMINALS TRANSMISSION CONTROL BOARD 2 WAY WIRELESS KEYPAD e g 5804BD TO FIRE DEVICES 5881ENHC OF 5800RL 2 WAY TRANSCEIVER RELAY MODULE SOLER OES Figure 4 Mounting UL Commercial Fire Applications NOTE For UL 864 Fire installations ECP Isolator PN ECP ISO is required sasaHc oo2vo ENCRYPTED KEYS The receiver can support up to 16 encrypted wireless transmitters keys at one time If the number on the receiver microprocessor is WAK 4406 4 or higher the receiver provides you with the capability to check space available and or delete encrypted keys using the procedures below The GREEN LED located on the receiver s circuit board may be used to determine how many more encrypted keys may be enrolled into the receiver This LED is also used to indicate when encrypted keys may be deleted To d
10. duce their detection ability Passive Infrared Detectors sense changes in temperature however as the ambient temperature of the protected area approaches the temperature range of 90 to 105 F 32 to 40 C the detection performance can decrease e Alarm warning devices such as sirens bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors If warning devices are located on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedrooms Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo radio air conditioner or other appliance or by passing traffic Finally alarm warning devices however loud may not warn hearing impaired people e Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service Telephone lines are also subject to compromise by sophisticated intruders e Even if the system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not respond appropriately e This equipment like other electrical devices is subject to component failure Even though this equipment is designed to last as long as 20 years the electronic compone
11. etermine how many more encrypted keys may be enrolled and or to delete enrolled encrypted keys 1 Remove power from the receiver and set DIP switch 1 to the ON position 2 Apply power to the receiver and watch the GREEN LED You will see one of the following indications a The GREEN LED blinks the number of spaces that are free for additional encrypted key enrollment and then goes to constantly ON b The GREEN LED is constantly ON indicating the receiver is full c The GREEN LED is OFF indicating no encrypted keys are enrolled 3 If you do not want to delete any enrolled encrypted keys advance to step 4 If you want to delete enrolled encrypted keys wait until the GREEN LED is constantly ON in step 2 a or 2 b above and then a Record the positions of DIP switches 1 through 5 b Set DIP switches 1 through 5 to the opposite positions of their current settings and wait a few moments c Set DIP switches 1 through 5 back to their original positions as recorded in step a All enrolled encrypted keys will be deleted 4 Place DIP switch 1 back into the OFF position to return to normal receiver operation SPECIFICATIONS Dimensions 7 3 8 W x 4 3 8 10 7 8 w antenna H x 1 7 16 D 188mm W x 112mm H 277mm w antenna x 37mm D 5800BOx 10 86 W x 5 41 11 9 w antenna H x 2 24 D 276mm W x 137 5mm H x 57mm D Input Voltage 12VDC from control s keypad terminals Current 60mA typical Operating Temperature 0 5
12. g lugs supplied with the receiver through the top of the cabinet into the left hand terminals of the antenna blocks located on the upper edge of the receiver board and secure them to the cabinet with the screws provided as shown in Detail D j Insert the receiver s antennas through the top of the cabinet into the blocks right hand terminals and tighten the screws k Affix the receiver s Summary of Connections label to the inside of the control s cabinet door l Discard the receiver s unused plastic cover and base 3 If the receiver is to be located remotely from the control in its own plastic enclosure not in a cabinet You will not need the circuit board mounting clips grounding lugs and screws included with the receiver a If concealed wiring is to be used route it through the rectangular opening at the rear of the base before mounting For surface wiring entry a thin breakaway area is provided along the base s right edge b Mount the receiver in the selected location For greatest security use all four mounting holes two key slot holes and two round holes provided in the plastic base c If installing a 5881ENHC install a flat head screw supplied in the case tamper tab as shown in Figure 2 When the receiver is pried from the wall the tamper tab will break off and remain on the wall This will activate a tamper switch in the receiver and cause generation of a tamper signal Note that this signal will also
13. n the ON position Insert the wiring plug with 4 flying leads into the mating socket on the receiver see Summary of Connections Diagram on back cover for socket location Connect the 4 wires to the control s corresponding keypad terminals see Interface Wiring in the SPECIFICATIONS section Install the antennas in the right hand terminals of the two terminal blocks at the upper edge of the circuit board one into each block s right hand terminal and tighten the screws to secure them Caution Avoid mounting the receiver antennas against a metal surface Replace the unit s front cover using the supplied screw to secure it Proceed with any programming of the control that may be necessary for RF operation and the installation of the system s wireless transmitters as described in the control s installation and setup guide and the transmitter s installation instructions NOTES e The receiver can support up to 16 high security encrypted wireless transmitters keys The total quantity of wireless keys encrypted and unencrypted that can be used is determined by the control panel e Wireless key buttons must be enrolled to zones in the control panel via zone programming first If the wireless key is to be used for arming and disarming the VISTA 40 and up a user number must then be assigned to the wireless key via user programming If it is not done in this order you will be unable to respond successfully to the RF b
14. nected to Keypad Port 2 in the control The keypad must be mounted on the control or within 3 feet of the control with the wiring encased in conduit e All power limited wiring must be separated from non power limited and high voltage wiring by 14 6 4mm Each receiver supports the number of zones shown below 5881ENM Up to 16 zones The number of zones that the 5881ENH receiver can support depends on the control with which it is used See the control panel s instructions for specific details If a receiver is connected to a system in which more than the permitted number of wireless zones have been programmed a SET UP ERROR message on alpha keypads or an E4 or E8 message on fixed word keypads will be displayed on the system s keypad and none of the zones will be protected The instruction manual that accompanies the control includes recommendations regarding receiver and transmitter locations the types of wireless zones that can be programmed e g ENTRY EXIT PERIMETER INTERIOR etc and the procedure for programming the receivers These receivers should not be installed in an area subject to environmental extremes of below freezing such as an unheated warehouse or extremely high temperatures such as an attic INSTALLATION With some controls a receiver may be mounted directly inside the control s cabinet receiver circuit board only without its plastic housing instead of remotely in its own housing
15. nts could fail at any time e The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance This alarm system should be tested weekly to make sure all sensors and transmitters are working properly The security console and remote keypad should be tested as well Limitations of this Wireless Alarm System Continued This system s wireless transmitters are designed to provide long battery life under normal operating conditions Longevity of batteries may be as much as 7 years depending on the environment usage and the specific wireless device being used External factors such as humidity high or low temperatures as well as large swings in temperature may all reduce the actual battery life in a given installation This wireless system however can identify a true low battery situation thus allowing time to arrange a change of battery to maintain protection for that given point within the system Installing an alarm system may make the owner eligible for a lower insurance rate but an alarm system is not a substitute for insurance Homeowners property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property We continue to develop new and improved protection devices Users of alarm systems owe it to themselves and their loved ones to learn about these developments FEDERAL COMMUNICATIONS COMMISSION FC
16. tenna leads away from any wire runs to the receiver control e Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits e Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT ICES 003 Class B Notice Avis NMB 003 Classe B This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada FCC IC STATEMENT This device complies with Part 15 of the FCC Rules and RSS 210 of IC Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme a la partie 15 des r gles de la FCC amp de RSS 210 des Industries Canada Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interferences nuisibles 2 Cet appareil doit accepter toute interference re ue y compris les interferences causant une reception ind sirable ANTENNAS ae USE MAX OF 220 ft 67m OF 22 0 64mm WIRE CIRCUIT OR 550 ft 168m OF 18 1mm WIRE FOR EACH RUN BOARD Se An 20 ft MAX IN COMMERCIAL FIRE INSTALL
17. tial is subject to compromise or failure to warn for a variety of reasons For example e Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device e Intrusion detectors e g passive infrared detectors smoke detectors and many other sensing devices will not work without power Battery operated devices will not work without batteries with dead batteries or if the batteries are not put in properly Devices powered solely by AC will not work if their AC power supply is cut off for any reason however briefly e Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver Even if the signal path has been recently checked during a weekly test blockage can occur if a metal object is moved into the path e A user may not be able to reach a panic or emergency button quickly enough e While smoke detectors have played a key role in reducing residential fire deaths in the United States they may not activate or provide early warning for a variety of reasons in as many as 35 of all fires according to data published by the Federal Emergency Management Agency Some of the reasons smoke detectors used in conjunction with this System may not work are as follows Smoke detectors may have been improperly installed and positioned Smoke detectors may not sense fires that start where smoke cannot reach
18. utton zone number prompt in user programming e If more than one receiver is being used and you are using encrypted wireless keys we recommend that you a enter the GO NO GO mode b disconnect one receiver c enroll all encrypted keys into the connected receiver d reconnect the disconnected receiver e exit the GO NO GO mode and then FRONT TAMPER REAR TAMPER 7 ECP CONNECTION SCREWS 4 TYP Z PLASTIC 7 CONDUIT y ENER ECURING ee SCREWS N K z Y 5883HC 001 VO Figure 3 5881ENHC UL Commercial Fire Installation f repeat a through e for the receiver that was disconnected e The RED LED located on the receiver s circuit board should be used as an indicator of strong local radio frequency interference If this LED is continuously illuminated the receiver should be relocated e After a successful enrollment of an encrypted key the GREEN LED blinks the number of spaces that are free for additional encrypted key enrollment 9 Replace the receiver s cover UL Commercial Fire Installation For UL864 Commercial Fire Installations you will need to purchase separately the 5800BOX in which the circuit board will be installed Follow the instructions below and refer to Figure 3 1 Mount the rear half of the 5800BOX directly to the wall in the selected location hinged side up Secure using the 4 screws provided and insert screw in tamper tab refer to Installation step 3c
Download Pdf Manuals
Related Search
Related Contents
Pegasus FS2AD202BNV Instructions / Assembly Rolls PARAMETRIC EQUALIZER, 4 BAND => Model RPQ160 Home Equalizer User Manual Muvit MUEAF0145 mobile phone case BAIER BSS 406M OMRON Audio-Technica ATH-ANC7B Becker Designed AR 3201 User's Manual OM, Gardena, Pompe pour fontaines d`intérieur/Pompe pour jets d Copyright © All rights reserved.