Home

sunny 512 dmx controller manual

image

Contents

1. Now the above scenes are running simultaneously Oo Pw N Tips In the step 3 of example 2 if press SINGLE key to make SINGLE indicating light on perform step 4 to run scene A10 and scene A02 will close automatically Running chase Running chase the screen will display CHASE TRIGGER STEP SPEED A08 AUTO 1 100 Chase number Current chase step Trigger mode Speed ratio Example 3 Running chase A08 1 Press SINGLE key of CHASE to make SINGLE indicating light on it is in the single chase running mode 2 Press 7 key to choose A as the current district Press 3 key to run chase A08 Example 4 Run A04 A13 B07 C10 chases at the same time 1 Press _SINGIE key of CHASE to make SINGLE indicating light off It is in the multi chase running mode Press A key to choose A as the current district Press 4 key to run chase A04 Press 73 key to run chase A13 Press 3 key to choose B as the current district afk oN 275 Sunny 512 User s Manual 6 Press 7 key to run chase B07 7 Press key to choose C as the current district 8 Press TO key to run chase C10 Now the above 4 chases are running simultaneously Tips If the chosen chase is empty without CHASE Step i ty Check the various operating parameters of multi chases running simultaneously When multi chases are running the last parameters are displayed in the screen In example4 the parameters of last chase C10 are
2. When the key is pressed the corresponding indicating light is on and indicates that the section is current section If current section is A press scene number key and A01 A16 scene can be operated If the indicating light of not current section is on it indicates that there are scenes are running in that section SINGLE Single scene key Set for each section respectively The key is used to switch the following states When SINGLE light is on the current section only can run a scenes When SINGLE light is off the current section can run multi scenes at the same time Scene number key Cooperating with scene section key 16 scene keys can operate A01 A16 B01 B16 C01 C16 48 scenes Using SINGLE key single scene or multi scenes can be operated CHASE Sunny512 console can save 48 chases in 3 saving section with 16 chases each A P E kev When the key is pressed the corresponding indicating light is on and indicates that the section is current section If current section is A press scene number key and A01 A16 chase can be operated If the indicating light of not current section is on it indicates that there are chases are running in that section Sunny 512 User s Manual SINGLE Single chase key The key is used to switch the following states When SINGLE light is on the c
3. CHASE N a gt gt cm w SELECT 1 gt o o Go o SCANNER CLEAR Clear key Clear all states chosen by scanner keys and quit manual operation Section key When the indicating light is on 1 16 scanner can be chosen from number keyboard 17 32 Section key When the indicating light is on 17 32 scanner can be chosen from number keyboard FOTO Scanner hold key When the indicating light is on it is a scanner hold state Multi scanner can be manual operated Scanner number key Press these keys the corresponding indicating lights are on and indicate the scanners are in manual operating states Sunny 512 User s Manual Press again there are two states HOLD light is off the scanner can t be operated manually HOLD light is on the scanner is in a hold state CHANNELS In manual state 16 channel slides can set the channel value of the chosen scanner CHANNELS must cooperate with SCANNER SCENE Sunny512 console can save 48 scenes in 3 saving section with 16 scenes each B Scene section key
4. SUNNY 349 User Manual Sunny 512 User s Manual AVALITES Sunny 512 scanner console is specially designed to control the various scanners To adopt double CPU work in coordination high speed MCU proceed the precise control to achieve 16Bit X Y movement Up to 32 scanners may be connected with a maximum of 16 channels each Multi scenes and multi chase programs can be operated at the same time and 32 scanners can be selected simultaneously It is equipped with two groups of DMX 512 signals and is adapted for wide range of power voltage The edit mode and running mode of the console are convenient and flexible So it is easy to edit and to handle Sunny 512 is the best suit for art show theater dancing and acting Features DMX512 1990 standard 512 DMX control channels 2 output with optical isolated withstand 2000Vrms Independent slot structure which is easy to change Up to 32 scanners may be connected with a maximum of 16 channels each A large backlight LCD to display operation parameters 16 sliders for channel 1 slider for speed control 1600 chase steps 48 chases up to 100 steps each Each step contains its speed and cross time can be set respectively Trigger mode selectable Music synchronously and manual speed Cooperating with the chase speed slider the time of the program step can be changed from 0 03s to 180s 48 scanner scenes can be used directly 4 cha
5. ate will run continually 16 Addenda Table 1 Explanations to display contents Display contents X H X L PRO RAN TA CHASE xxx Step is empty VIEIVIOR Y OVER OVW Sunny 512 User s Manual Explanations X axis coarse channel high 8Bit channel X axis fine channel low 8Bit channel Y axis coarse channel high 8Bit channel Y axis fine channel low 8Bit channel For 8Bit scanner only X Y coarse channel can be used So the X Y fine channel must be set to no Abbreviation of CHANNEL The chase step with is the last step of the current chase Use key can switch the display contents The parameter in the is the current adjustable item Its value can be change by modulation wheel Chase edit state The chase with this number is empty the chase number is replaced by xxx There is no space in memory Ags Table 2 Sunny 512 User s Manual Control channel data of the ordinary scanner Scanner model nt nt Golden scanner SGM GALILEO II SGM GALILEO Trackspot Bond scanner Martin Roboscan Pro 1200 XR Protocol 1 Martin scanner 1200XR Martin Roboscan Pro 518 Mode 3 Martin Scanner 518 Martin Roboscan Pro 218 Mode 3 Martin scanner 218 FAL ITALSCAN HMI 1200 Fly eagle scanner CLAY PAKY GOLDEN SCAN HPE Channel Control type Color Disc2 Dimmer Strobe 6 TUL I Ban ee Tr sn Rotation Gobo Select Gobo Rotation Color Select cee eee Gob
6. chases are running there are scene or chase running on the section Sie Sunny 512 User s Manual Cautions Danger there is high voltage inside the equipment avoid getting an electric shock Caution please don t open the equipment There is no part that can be repaired by the user Using the equipment the power supply must be connected to the earth line to ensure the safety When console and scanner are working don t plug or pull out DMX512 data cable with the power on This will destroy the port electric components of the console Don t splash any liquid to the scanner console This will shatter the inside components of the console and make functions failure Scanner console is precision electric equipment Please pay attention to moistureproof protection and dustproof protection And please clean the control panel in schedule with non chemical cleanser Contents Contents in the package Sunny 512 scanner console 1 Users Manual 1 QC card 1 Power supply line 1 Connect to scanner Sunny 512 console has 2 optical isolated DMX512 signal independent drive device So there are 2 DMX512 XLR D3F The connection of the output socket and the data cable as following Foot No Data cable 1 Screen net 2 Signal 3 Signal In the end of DMX512 data cable a 120 amp matching resister must be connected to the end of the cable to improve the signal transmission quality 1202 Cable terminal impedance matchi
7. displayed in the screen If the parameters of some chases are want to be change the chase must be set as current chase and the chase is display in the screen For instance in example 4 here the parameters of last chase c10 are displayed in the screen If the parameters of BO7 are wanted to be seen just press E 7 press key and hold then press key This method does not affect the current chase running Adjust chase speed The operating speed of the current chase can be change by moving SPEED slider chase step time value x speed ratio real running time of the current chase step Using the method of checking operating parameters of multi chases running simultaneously make a chase to be current chase one by one Then set its chase speed The music trigger of a chase Press MUSIC key to make MUSIC indicating light on It indicates that the current chase is in the music in phase trigger state In this state the chase step time and the gradual change ratio Cross don t work Run Environment Press SETETT key then press 7 E number key to make the corresponding indicating light on The chase scene and manual operating included in this environment will reappear Every corresponding indicating lights are on Example 5 Run Environment 1 1 Press SELECT key 2 Press T_Jnumber key Press SELECT key again and press the number key which light is on The corresponding environment is closed Then the original st
8. e speed slider Push the slider to FAST chase runs faster Push the slider to SLOW chase runs slower The changeable range is 300 30 When SPEED is 100 chase step runs on the set time and the set cross time When the higher speed is needed SPEED should be adjusted to smaller than 100 The fast is 1 3 of the standard speed when SPEED is 30 When the slower speed is needed SPEED should be adjusted to larger than 100 The slowest is one third of the standard speed when the SPEED is 300 DAME LAMP 12V work lamp socket The power of the lamp is smaller than 6W POWER POWER Power switch of the whole equipment Sunny 512 User s Manual Introduction to the rear Pireu m muxar Dagi PRIX 4 maam en DRIFT Y peor I Power Power DMX512 output RN input Work lamp fuse input fuse Explanation There are 2 optical isolated DMX512 output sockets which have the same signals Audio signal input socket is a 1 4 mono socket with 10 10dB input level When the plug is connected music trigger signal comes from audio input signal When the plug is pull out music trigger signal comes from the environment sound picked by the inside microphone Please use the standard fuse The standard is printed on the backboard The power supply must be connected to the earth line to ensure the safety Sunny 512 User s Manual Set X Y channels for scanners Sunny 512 scanner cons
9. en two chase steps The range of the value is 0 100 For instance in the current step Time 10 Cross 60 express that the current step will use 1 second and use 40 of this 1 second as stay time 60 as gradual change treatment time for moving to the next step Process of chase edit 1 Press EDIT CHASE key PROGRAM CHASE Please select a chase 2 Choose the chase number which will be edited For instance if want to edit chase PROGRAM CHASE C15 press C7 key in CHASE then CAEC Ed press 75 key if the chase is empty the screen will display 3 Press ADD key to add a step Current step Pchase Total Step Step Time Cross gt C15 1 1 5 0 A A Current edit Current sit sion Default 0 number is last step Default 5 Unit 0 1s 4 Use modulation wheel 4 to change the items such as STEP TIME and CROSS Use modulation wheel AV to set the value of the current item 5 Set the channel values of various scanners in the current step manually Use key to change the setting state of chase step the various channel values of manual operating scanners and the setting state of X Y 6 Repeat step 3 5 to edit next chase step 7 Press EDIT CHASE key to end edit Tips When ADD key is pressed to add a chase step the values such as the channel values of all scanners the values of TIME and CROSS are copied to the new added chase step automatically So just change some items to make a new chase step If the cu
10. modulation wheel the corresponding X Y slider is locked The X Y position of a scanner must be set by modulation wheel In the manual mode of a scanner slider and modulation wheel can change the value of the corresponding channel The screen displays the value of these channels When the scanner key is pressed the X Y current appears at the right part of the screen Turn the modulation wheel the values of X Y can be changed 10 Sunny 512 User s Manual Move 1 8 channel slider the screen displays CH 2 3 4 5 6 7 8XI20 123 58204 32 12 0 0 0 891 Move 9 16 channel slider the screen displays 5 0 Y 891 Note the values of channel and X Y depend on the slider position and the X Y modulation wheel value In a moment of slider moving the value display will disappear until the next moving Manual operation of single scanner __ 1 Press f HOLD key to make the indicating light off 2 Choose scanner press scanner number key cooperate with 1 16 Jand 732 keys the indicating light is on 3 Use CHANNELS sliders to set the channel values use modulation wheel 4 and AV to adjust X Y position Manual operation of the same kind multi scanners 1 Press HOLD key to make the indicating light off 2 Choose scanner according to the 2 step of Manual operation of single scanner multi scanners can be chosen Note only the scanners with the same X Y channel can be chosen at the same time 3 Use CHANNELS sliders to se
11. n multi scenes running simultaneously c Chase operation up to 4 chase running simultaneously After pressing SAVE TO ENV key a If no environment program in current Save the Current Environment to environment the screen displays as Ok gt left figure b If the current includes the environment program the number of the environment is displayed If ENTER7 SWITCH key is pressed the current environment will cover the contents of the original environment If it is needed to save to another number then Press SETETT key Press 7 75 key PresfENTER 7 SWITCH key to conform Tips To save the environment it is not needed to pres SELECT key first To run environment it is needed to press SELECT key first and then press number key a s Sunny 512 User s Manual Running Running scene Example 1 Single running scene A01 1 Close running scene B and C one by one 2 Press A key to choose A as the current district 3 Press key to make SINGLE indicating light on A district is in the single scene running mode 4 Press 7 key to run scene A01 Example 2 Run A02 A10 B15 C07 scenes at the same time 1 Press A key to choose A as the current district Press SINGLE key to make SINGLE indicating light off It is in the multi scene running mode Press key to run scene A02 Press 77 key to run scene A10 Press key 75 key to run scene B15 Press C key 7_ key to run scene C07
12. nce using simultaneously running scene BO2 and C07 as basic choose 3 scanners manually and set the light beam to some position then save the combination to scene C01 So run C01 can recur this light art pattern combination Copy of Scene Example Copy scene A01 to scene C10 1 Pres A key in SCENE then press _T key Then the console run A01 scene 2 PresfSAVE TO SCENE key press C key in SCENE then press 77 key and key Chase Edit Sunny512 console can save 48 chases A chase is a buildup of some chase steps The concept of chase step is very similar to the scene A chase step is made up of the aggregation of each channel value of various scanners the step time and the graduate change parameter Cross The total capability ofthe chase step is 1600 Each chase can have up to 100 step In each step of a chase the step time and the gradual change parameter Cross can be set independently The standard operating speed of a chase is decided by the step time and the gradual change parameter Cross of a step The speed can be adjusted from 1 3 to 3 times as the standard speed by SPEED slider Sunny 512 User s Manual Step time value The value defines the interval time between the current to the next step The unit is 0 1s The changeable range of Time is 1 600 It means that the minimum time of a step is 0 1s and the maximum is 60s Cross value The value defines the time ratio of the gradual change treatment betwe
13. ng resister The set of the scanner address Sunny 512 User s Manual Sunny512 console distributes the DMX512 address of various scanners with the fixed space of 16 channels The reference is as following Avalites Binary Avalites Switc N CD O N N oO co Co o gt N pare N N Scanner No Avalites Binary Avalites Switc Scanner No CD Avalites N gt N O CD N N oO co oa N J CD CD N Binary Avalites Switc Since the first address set is different for various scanner manufacturer There are two ways to express 512 channels the first is 000 511 the second is 001 512 The above table is suitable for the product of the second way For the product of the first way we should subtract one from the above address and the first bit of the binary Avalites switch should be changed from 1 to 0 Sunny 512 User s Manual Introduction of the panel The panel is as following POWER BLACKSUT LAYP ee SCAN CLEAR HP THT HE SUNY 545 Sse
14. nnel 6 ZT z Y coarse channel 7 Y fine channel 8 ch Y L no Y L 8 The setting of 16Bit scanner Scanner a ae Scanner s number Setting the corresponding channel number is current item The setting of 8Bit scanner Scanners number Setting the corresponding channel number is current item Sunny 512 User s Manual For 16Bit scanner if the values of X H Y H are set and the values of X L Y L are set to no the 16Bit scanner will be running in 8Bit X Y resolution This will lost some characteristics of 16Bit scanner such as high precision of X Y orientation and the smoothness of the moving trace Auto correction to the wrong setting X L no Y L no must be set at the same time That just one is no is a mistake Sunny512 checks and corrects X L Y L to be no at the same time automatically Check the X Y setting of the scanners Use following ways to check Press SEX key the indicating light is on It is in setting scanner s X Y state Use scanner keyboard to choose scanner Check the X Y setting 1 2 3 Repeat step 2 to check X Y setting of all scanners 4 Press SET XY key to quit the edit state The manual mode The scanner s channel values such as intensity gobo X Y pattern and color can be set manually Usually the control contents of each channel of various scanners are different With the particular comprehension to the control contents of each channel of
15. nny 512 User s Manual DMX512 1990 512 32 16 16bit 2 2000VDC 40 character x 2 row 32 48 48 48 100 0 15 60s 0 100 1600 4 10 10dB audio line input inbuilt microphone 16 1 30 300 2 15 XLR D3F x 2 1 4 mono socket AC 90V 250V 50 60Hz 15W 0 40 C Waterproof dustproof 483mm x 400mm x 105mm 8kg Tel 86 020 36405709 FAX 86 020 36405709 Mobile 13610105629 http www xinhualight com http www xinhualight cn
16. o Rotation 8 DIMMER Color Select PAN TT Gobo i oo Dr motor Speed FS DT Srobe Fan Speed Lamp on off Reset Pure 2 Intensity ee D E 5 Rotating Gobo selection DS DI hm Pan Dimmer ERR Pit 1 Shutter Strobe SA Reset fixture SE e es le a ae 2 ec 5 sa I 5 Pan Od Oy AE wf OO IN AP ofp ny Cot ph 18 Technical specification Digital control mode DMX control channel amount Control scanner amount Control channel distribution of a scanner control resolution of a scanner optical isolated independent digital output drive module Electrical isolation of optical isolated independent digital output drive module LCD backlight screen BLACKOUT function Manual operation function Simultaneous manual operation ability Scanner scene Scene amount of simultaneous running scanners Scanner chase Maximum chase steps in a chase Chase step time Chase gradual change ratio Cross Total capability of chase steps Chase amount of simultaneous running scanners Music in phase chase Channel sliders Speed slider The ratio range of chase speed MODULATION WHEEL Environment Copy of scanner scene All scanner X Y channels can be controlled by modulation wheel Data auto save DMX signal output connector Audio signal input connector Power supply range Consume power Work temperature range Work environment Size Weight 19 Su
17. ole can control the scanners with 8Bit or 16Bit X Y resolution Before Sunny scanner console uses modulation wheel to control the X Y position of any DMX512 standard scanner the address of every scanner must be set and the set control channel number of each scanner must be written to the console one by one X axis of 16Bit resolution scanner is controlled by two data channels Y axis is controlled by two data channels too So X Y is controlled by 4 data channels X axis coarse channel high 8Bit X axis fine channel low 8Bit y axis coarse channel high 8Bit and Y axis fine channel low 8Bit For 8Bit resolution scanner X Y is controlled by 2 data channels X axis coarse channel and y axis coarse channel The explanations of the display can be seen in append table 1 Setting operation of X Y From the Users Manual of the scanner whether the scanner is 8Bit X Y or 16Bit X Y and the attribute of the corresponding channel can be known 1 Press SET X Y key the indicating light is on It is in setting scanner s X Y state 2 Use scanner keyboard to choose scanner 3 Use modulation wheel 4 to choose edit item 4 Use modulation wheel AV to choose the value of the corresponding channel range 1 16 no 5 Repeat step 2 4 to set X Y of the other scanners 6 Press SET X Y key to quit the edit state For example Some 8Bit item value Some 16Bit scanner Item value Scanner XH 77 X coarse channel 5 XH 5 X 5 Y 7 x m X fine cha
18. ress environment number key the environment is saved to the number of environment SET X X Y set key Write the X Y control channel number of various scanners to the console then use modulation wheel to control the position of the various scanners DELETE Delete key When the chase is edited press the key to delete the current chase step Add key When the chase is edited press the key to add a new chase step after the current one If the current chase step is the last one of the chase the parameters of the current chase step are copied automatically to the new added chase step Sunny 512 User s Manual Enter Switch key In scene edit and environment edit itis ENTER key In chase edit it is SWITCH key gt lt gt AY Modulation wheel gt A SSN In edit chase 4 is used to change edit item A Vis used to set the value of the item In manual operation mode lt d is used to set the X position of JA Se ascanner AY is used to set the Y position N Other most Music trigger key E When the indicating light is on chase follows the music rhythm When the indicating light is off chase follows the set time multiplying the speed percentage set by SPEED slider BLACKOUT Blackout key Berl When the indicating light is blink console run an inside black scene automatically When the indicating light is off console is in the normal state SPEED chas
19. rrent chase is empty all channel values are set to 0 In the edit state use ENTER7 SWITCH key to switch between the chase setting state and manual setting state which set the various channel values and X Y values of scanner In different state the control object of the modulation wheel is different In chase setting state use modulation wheel AV to change the current step This can check the space pattern effect of every chase step and can change the channel values of some scanners in the current chase step immediately Press DELETE key to cancel the current chase step 13 Sunny 512 User s Manual Environment Edit The current manual operating state scene operating state and chase operating state are the operating environment If the current environment is saved it is very convenient to reuse this environment A complex environment like an environment some chases some scenes some manual operation can be saved as an environment It can be saved to cover the original environment number or saved as another environment number Sunny512 console can save 15 environment The environment can be chosen by keyboard directly To avoid mistake made by touching keyboard by accident it is needed to press SELECT key first and then press the environment number key to choose the environment Edit process 1 5 Base on the need to choose the following operating mode a Scanner manual operation b Scene operatio
20. ses 48 scenes operated at the same time At most 32 scanners can be selected simultaneously The X Y channels of different scanners can be controlled by modulation wheel 16Bit control for absolutely precise movement 15 environment programs to output the combination which are composed of different scenes chases and manual output quickly The music trigger source can be selected between audio line input or inside microphone Easy to edit and handle The Data auto saves High performance switching power supply with extremely low power harmonious distortion and wide range of voltage suit for the requirement of different country Explanation for Reading For reading convenience some signs and usual displays are specially defined as following xxx expresses a key like HOLD When the parameter is inside on display like 012 the parameter is the current choice Press x yy expresses press xx key first and hold then press yy key X Y control is named Pan Tilt also In the Manual it is X y the control of X axis Y axis When the key indicating light is on it indicates that the key has been pressed chosen or the function is effective When the indicating light is blink BLACKOUT EDIT function key emphasizes the function Scanner number key expresses that the computer is in a hold state Scene section key and chase section key indicate that when multi scenes and multi
21. t the channel values Use modulation wheel to adjust X position Use modulation wheel to adjust Y position And the adjusted channel values are set to all chosen scanners at the same time Manual operation of the different kind of multi scanners For the manual operation of the different kind of scanners set one kind of the scanners and make these scanners in the hold state first Then choose another kind of the scanners to set This is also the usual operation method to set 1 scene The hold state of the scanner can be change to the choosing state by pressing its key to make the indicating light on 1 Press HOLD key to make the indicating light on 2 Choose scanner use the way of choosing single scanner or multi scanners to choose scanners Note only the scanners with the same X Y channel can be chosen at the same time 3 Use CHANNELS sliders to set the channel values Use modulation wheel 4 and AV to adjust X Y position 4 Press the corresponding number key of the chosen scanner to make the indicating light blink The set values of these scanners are in the hold state And the adjusted channel values are set to all chosen scanners at the same time 5 Repeat 2 4 steps to set other scanners manually Cancel the manual operation of scanner Press key the manual operation is canceled and the set values of the scanners can not be saved y p Sofie Sunny 512 User s Manual Scene Edit The appropriate values of channels s
22. uch as color intensity pattern X Y and so on of various scanners can make a needed light art pattern in the space scene Each scene is an aggregate of the set channels of the various scanners Sunny512 console can save 48 scanner scenes The saved scenes can be run at any moment Important tips For the simultaneous running of the multi scenes and multi chases the different values of the same channel which are produced at the same time are treated by HTP Technique So following setting is proposed 1 For all scenes which just include pattern effect controls such as color pattern and so on the values of X Y intensity and so on are set to 0 2 If chase just include the controls like X Y intensity and so on the values of the other channels are set to 0 Process of scene edit 1 According to the ways of manual operation choose scanner and set the various channel values and X Y position 2 Press SAVE TO SCENE key then press scene district key and scene number key In the end press key to confirm the save Example If you want to save the current scanner running states to A13 scene press SAVE TO SCENE key then press A key in SCENE and press T3_ key in the end press ENTERT SWITCH key Tips Scene edit can be done at any time After the various setting to multi scanners if the art pattern is what you want just perform the above step 2 The running states of all scanners can be saved to a scene number For insta
23. urrent section only can run a chase When SINGLE light is off the current section can run up to 4 chases at the same time The key is effective for 3 chase sections Chase number key Cooperating with chase section key 16 chase keys can operate A01 A16 BO1 B16 C01 C16 48 chases Using SINGLE l key single chase or multi chases can be operated ENVIRONMENT ENVIRONMENT SELECT 4 7 o o SELECT Environment choice key Press the key first then press the environment number key the environment can Ola be run or stopped 7 75 Environment number key At anytime only one environment can be chosen Edit SAVE TOSUENE Scene save key Save the current channel values of the scanners to a scene with EDIT SAVE TG EDIT SAVE TO HASE ENV JELETE ADD o some number Set the channel values of various scanners with manual operation or add some scenes then press the key first and press scene section key and scene number key The current channel values of the scanners are saved to the number of that section EDIT CHAS Chase edit key Press the key the indicating light blink It is in the chase edit state Press the key again the indicating light is off The edit result is saved and the edit state is quitted SAVE TUENY Environment save key Press the key then p
24. various scanners the scanner connected to the control net can be controlled with facility The control contents of each channel of ordinary scanners can be seen in the append tables In the edit state or running state it can be operated manually Manual operation is the highest priority operation The chosen scanner will be divorced from the running scene chase and environment automatically Manual operation is the basic operation Manual operation especially multi scanner manual operation can be saved as scene which is the basic operation of edit chase step Cooperated with 7 7 and 17 32 keys E 75 keys can make choice to 32 scanners When the number indicating light is on that scanner is in the chosen state It can be set by CHANNELS slider and modulation wheel CHANNELS 1 16 channel slider and modulation wheel The values of each channel of scanners can be set by 1 16 channel sliders X channel of a scanner is set by modulation wheel 4 Y channel is set by modulation wheel AY The set range of a slider is 0 255 Whether 8bit or 16Bit X Y scanner the set range of a modulation wheel is 0 999 It represents the moving range of X axis or Y axis For 16Bit scanner modulation wheel lt P controls X H and X L at the same time Modulation wheel AVY controls Y H and Y L at the same time For 8Bit scanner modulation wheel lt gt controls X H only Modulation wheel AV controls Y H only When the X Y channel is controlled by