Home

Owl Intuition-lc Manual

image

Contents

1. Le with you alongside the Network OWL until Step F Six You should NOT fit the Sensors at this time so lat ie Te INSERT 3 x AA BATTERY STEP TWO Power up Network OWL e Ensure antenna is screwed finger tight onto brass connector on side of the Network OWL e Select UK or Euro adaptor as required Fit to the power supply and rotate T until it latches into place e Plug the power supply into the mains and insert the DC jack connector into the base of the Network OWL e The green LED will flash rapidly After about 30 seconds the blue LED will start a steady flash aN indicating that it is in Pairing Mode E ae ee ely move to Step Three 5 S GREEN LED we BLUE LED CHECK FINGER LE TIGHT PLUG IN DC POWER CONNECTOR 2 2 Save Energy Limited 2012 STEP THREE Pair Transmitter to the Network OWL Ensure the Transmitter is next to the Network OWL hN Press the small Check button in the Transmitter 1 ECE 6 battery compartment until the red LED on the ee front starts flashing The Transmitter is now in Check Mode and the io 3 red LED on the front will start flashing every 2 seconds for 30 seconds The pairing process will now take place and the blue LED will start flashing a fraction of a second after the red LED flashes H e When the Transmitter Check Mode finishes if the pairing was
2. digits UK only enter just the first part of your postcode eg For RG24 9LR just enter RG24 Town Letters Outside UK only enter the name of the nearest Town or City to where this OWL Intuition system is physically installed System Type Select from list Intuition Ic STEP EIGHT Log in to your OWL Intuition account You can now log in to your OWL Intuition account with your new username and password at https www owlintuition com IMPORTANT Before progressing please check the signal strength of the radio signal between your Transmitter and Network OWL Also it is recommended that you enter your own Tariff details which can be accessed by pressing the Settings gear wheels icon on the Electric ity widget a auil Signal strength indicator Settings icon If the signal strength is only 1 or 2 bars to reduce the chance of intermittent inconsistent data reception it is suggested that you reposition the Network OWL so that it is physically closer to the Transmitter The Network OWL should ideally be hung on the wall in a free area as far from large metal objects as possible Position the antenna in a vertical orientation If necessary you can replace the Ethernet cable with a longer cable up to 100 meters long If installing a long Ethernet cable is a problem you can use a Powerline Range Extender or Wireless Range Extender please search for these common products online 2 Save Energy Limited 20
3. Graphs Graphical views of historic Electricity Usage for each individual phase Status amp Settings e None Overview Widget Electricity Yesterday Maximum Minimum and Average recorded consumption rates kW CO2e Calculated CO2 emissions in kg s for Yesterday Last Week and Last 30 Days Adjusted for any Solar PV electrical energy generated and consumed Solar Yesterday Maximum and Average recorded Solar PV generation rates kW together with the amount of electrical energy kWh Imported from the Grid Consumption Generated Imported 2 Save Energy Limited 2012 11 Solar Financials Financial value of electricity generated Yesterday Last Week Last 30 Days and Since PV system was installed News Widget News and interesting articles relating to OWL products company news and energy saving in general Your OWL Intuition Ic system should now be set up and ready to help save energy CO2 emissions and money Please check out the other products in our OWL Intuition range such as heating controls that extend the capability of your Intuition system Customer Support If you have any further questions please check our frequently asked questions at http www theowl com faqs html You can also email us at customer services theowl com please ensure you state your Network OWL MAC ID 2 Save Energy Limited operate a policy of continuous development and improvement therefore the content of this document is
4. available will be posted into your Inbox A green numbered badge will appear next to this menu bar item when you have unread messages For maximum benefit please read these messages as soon after they appear as possible Shop Clicking this menu bar item will open a new tab within your web browser and display the home page of the OWL online shop Logout When you have finished using your OWL Intuition account please Logout by clicking this menu bar item Please note you can only log in one web browser at a time If you log in a second time then the first connection will be logged out If you or the browser refreshes the page you will have to log in again Weather Current weather conditions for your home building location are displayed The location is defined by the part postcode or Town you gave during your OWL Intuition account setup Future OWL Intuition products will use current and forecast weather to dynamically optimise energy saving System Status In normal circumstances providing your broadband Internet connection is working the System should always show as being Online with a recent last updated time Widgets General Information There are normally 3 Widgets visible whenever you are logged into your OWL Intuition account You can view any additional Widgets you may have by scrolling them with the arrows to the left and right of the screen In general the top section of each Widget provides you with appropriate
5. eN must go through Step Seven he the Web Dashboard Create i N Al Account process again but Y ticking Account Exists RESET E BUTTON S q PLUG IN ETHERNET CABLE STEP FOUR Connect Network OWL to the Internet Plug the Ethernet cable into the base of the Network OWL and a spare LAN port on your existing broadband Internet router Ensure the connector latches with an audible click at both ends and that there is activity on the green amp yellow LEDs above the Ethernet connector Ensure so far as possible that there are no large metal objects in the radio direct path between installed locations of the Network OWL and the Transmitter The wireless range is up to 30 metres free space Walls and large objects will reduce this range Note The table below describes the meanings of the LEDs visible on the front face of the Network OWL Network OWL LED Meanings Steady flash following power up N OWL is in pairing mode Flash every 12 to 60 seconds Data received from paired Transmitter Off for longer than 60 seconds N OWL is not paired or Transmitter is out of radio range Green Rapid flashing N OWL is starting up Green Single blip N OWL is running Green Double blip N OWL is running amp Connected to LAN DHCP IP address allocated Green Triple blip N OWL is running amp Connected to LAN DHCP IP address allocated amp Connected to OWL servers N OWL Online Green S
6. high level sum mary information Trend arrows appear where appropriate next to data values if you hover your mouse point over the arrow a summary of the change will appear in a pop up Above the Widget title bar is one or more action icons that provide access to more detailed information and control options If you 2 Save Energy Limited 2012 9 hover your mouse over one of these action icons a description of its function will appear If appropriate the grey Widget title bar has a gear wheels icon on the right Clicking this icon will pop up a window that will allow you to con figure this part of the OWL Intuition system to match your specific installation Be sure to click the Save button before closing the window Widgets Graphs When you click on a Graphs action icon a double size graph panel will ap pear next to the Widget Graph selections Typically a graph will show relevant data for the last 7 days You can select a shorter or longer Time Frame 1 day 1 Week 1 Month 3 Months 6 Months or All by clicking the appropriate button at the top of the graph Select an appropriate Group By None Day Week Month Year then chose the data you wish to Display Energy or Cost Finally to update the graph with your new selections click on the Reload button Please note that not all permutations are possible and invalid options are greyed out Hover over analysis B
7. secure connection Click Create Account and fill in the information requested see following table for explanation of the information required Ensure you correctly select the system type as Intuition Ic Press the Create Account button Successful account creation and configuration will be confirmed Please keep a note of your details and press the Finish button Account Set Up Information Required Username Letters amp digits Choose a memorable account username a mini mum of 6 characters long Not case sensitive Password Letters amp digits Choose a memorable password a minimum of 6 characters long Password is case sensitive Email Valid email ad Enter the email address you wish us to be able dress to contact you on Network OWL 12 characters MAC ID can be found on back of the Network ID OWL and starts 443719 Enter the full 12 characters Country Select from list The country where this OWL Intuition system is physically installed Timezone Select from list The time zone where this OWL Intuition system is physically installed Use Daylight Tick Tick this box to enable automatic adjustment for Saving daylight saving Not available for all countries Currency Select from list Select the currency symbols to be used by this account 2 Save Energy Limited 2012 Voltage 100 to 260 Enter the normal voltage of the system being monitored Default is 230 volts Postcode Letters amp
8. 12 7 INFORMATION amp TROUBLE SHOOTING TIPS Unless the Transmitter is in Check Mode the red LED does not flash in order to prolong battery life Check that the blue LED on the Network OWL flashes every 12 seconds if the monitored electricity supply consumption is varying or every 60 seconds when at a steady state If the blue LED does not flash then the Transmitter signal is not being received or the Transmitter Pairing has been lost Disconnect the Transmit ter s Sensors and move it near to the Network OWL to confirm radio range is not an issue For wireless range testing you can make the Transmitter send its signal every 2 seconds for 30 seconds by pressing the Check button in the battery compartment for 10 seconds The red LED will flash with each transmission the Network OWL blue LED will flash to confirm the signal has been received Network OWL Ethernet port LEDs have the following meanings Green link ok up Yellow data activity 2 Save Energy Limited 2012 WEB BROWSER INTERFACE All versions Overview Designed to be clear and easy to use you are encouraged to explore the vari ous information panels called Widgets that you have available The Widgets available will vary depending upon the system options you have purchased Clicking on the arrows on the left and right of the screen will scroll between your Widgets if required Messages OWL Intuition system messages and EcoNudge when
9. 22 are opened outbound Without this the Network OWL will not be able to connect to the OWL servers and your Intuition system will not function STEP SIX Install Transmitter and attach Sensors OWL Transmitter Transmitter Number Wire Colour IEE Colour Socket i Brown Red 1 tet Ea 2 Centre Industrial 3 Right epa Fuse Box me Distribution Board a Ring Mains gH Lights Ii Machines etc A J ezm P3 L3 ES Sensor Neutral P1 L1 P2 L2 P3 L3 Utility Meter Blue Brown Black Grey Alternative lt A 4 Sensor Locations Electricity Grid Intuition Ic Transmitter amp Sensors 2 Save Energy Limited 2012 5 Locate the supply cables between your electricity meter and mains distri bution board fuse box See diagram above Using the latch clamp the 3 Sensors around the insulated Live cables go ing into the meter as per the table in the diagram Live cables either side of meter is acceptable The Sensors must be a loose fit onto the cables Plug the Sensors into the associated Transmitter socket The Transmitter should be hung on the wall in a free area as far from large metal objects as possible STEP SEVEN Create Intuition online account Using the web browser on your computer open up the following page https www owlintuition com this is a
10. Getting started with OWL Utuition tc Electricity consumption monitoring three phase for larger homes and light commercial premises OVERVIEW The OWL Intuition Ic electricity monitoring system comprises of three major components e Electricity monitoring Sensor clamps and wireless Transmitter e Internet interface Network OWL wireless gateway e User interface A web browser or smart phone app IN THE BOX a gt i 4 ONNL gt NY N J y Network OWL gateway with external antenna 3 x plug in large Transmitter unit Sensor clamps 3 channel lt 17mm cable lt 200A j Plug top mains power supply 100 240V AC 5V DC 2 Save Energy Limited 2012 with Dead Euro adaptors 1 3 x AA alkaline battery BEFORE YOU START Please locate and check that you have a spare LAN port available on the back of your broadband Internet router You will need to plug in the supplied Ethernet cable If all of the ports are in use you can add more connections by purchasing an Ethernet Switch Hub You will also need a spare mains socket available close by for the supplied Plug top mains power supply STEP ONE Insert batteries into the Transmitter Slide back cover off of the Transmitter and insert the batteries into the unit Keep the Transmitter PART ci CMR180i MADE IN CHINA Eu
11. ingle long flash Connecting to OWL log servers Green Double long flash Uploading logged data to OWL servers STEP FIVE Wait 2 mins for Network OWL to come online Once the Ethernet cable has been connected you should see the green LED quickly progress from single blips to double blips It will now normally take up to 2 minutes for the Network OWL to securely connect to the OWL servers indicated by a triple blip on the green LED Do not progress to Step Six until the Network OWL is online IMPORTANT Internet Connection Notes The Network OWL can normally connect to the OWL servers when plugged into a normal domestic broadband router which has a default security configuration If the Network OWL does not connect within 5 minutes a Ensure that your Internet connection is working by connecting to a 2 Save Energy Limited 2012 familiar site using your web browser b Check Ethernet cable connections remove cable and refit a few times at both ends to remove any dust on the connections c Try rebooting your broadband router by powering down for 10 seconds and then power back up Allow 5 minutes for everything to re establish itself IMPORTANT Note for business users e If you wish to use a Network OWL connected to a business commercial LAN then please note that it is usual for the internal IT Security Department to restrict which Internet ports are open for use e You will need to ensure that ports numbered 5004 and 52
12. subject to change without notice Document Version 1 5 October 2012 12 2 Save Energy Limited 2012
13. successful the blue LED will flash every time it receives data from the Transmitter PRESS every 12 to 60 seconds CHECK BUTTON Replace battery compartment cover o i feu D frum Fawr ums tavp IMPORTANT Pairing Notes amp Network OWL Factory Reset 2 Save Energy Limited 2012 If you don t complete the pairing process within 60 seconds of the Network OWL blue LED starting its steady flash restart the process by removing and re inserting the DC power jack You can quickly check for correct pairing at any time by pressing the Transmitter Check button until the red LED starts flashing if the Transmitter red LED and Network OWL blue LED flash together they are correctly paired If you remove change the Transmitter batteries you will need to remove the existing pairing from the Network OWL and pair the Transmitter again To clear ALL pairings in the Network OWL including other paired devices such as heating controls carry out a full Factory Reset as follows e Factory Reset the Network OWL by pressing the reset button while the power is on Carefully insert a paperclip into the small hole and hold the button pressed for a minimum of 10 seconds and release The green LED will flash rapidly E After about 30 seconds the blue LED will start a N steady flash indicating that it is in Pairing a i Mode After each Factory Reset you K
14. th trend information when available 10 2 Save Energy Limited 2012 Action icons available e Electricity Data Export Prompts for Start amp End dates up to 1 month apart Will then download a CSV file containing detailed data recorded for this period Download the Help file for full details e Electricity Graphs Graphical views of historic Electricity usage Status amp Settings e Transmitter Battery Displays Good or Replace Soon e Transmitter Signal Strength 1 bar poor to 4 bars good e Settings Tariff type Tariff standing charge Rate per kWh Solar Widget Live display of your current Solar PV electrical energy generation in Watts kW together with the current power you are exporting to the grid Also shows Solar PV electrical energy generated and exported for Today so far Yester day Last 7 Days and Last 30 Days with trend information when available Action icons available e Solar Graphs Graphical views of historic Generated Solar Power Exported Solar Power and Imported Electricity Status amp Settings e FITS Tariff settings Generation Tariff Export Tariff amp Assumed Export 3 Phase Electricity Widget Live display of your current overall electrical energy consumption in Watts kW for each of your 3 individual phases Also shows for each phase the elec trical energy used for Today so far Yesterday Last 7 Days and Last 30 Days Action icons available e 3 Phase Electricity
15. y moving your mouse pointer over the graph a pop up window will open showing detailed values for the focus points marked on the graph Where appropriate date and time information for the currently displayed focus points will also be shown Simply move the mouse pointer from left to right and the focus points and information window will automati cally update Zoom in If you want to take a closer look at the graph you can zoom in to the part that is of interest Move your mouse pointer to the start of the area of interest click and hold drag to the end of the area of interest and release The graph will automatically zoom in on the area selected Click the Reset zoom button when finished Print Download buttons If you want to keep a hard or soft copy of the displayed graph then use the Print or Download buttons located just above the graph on the right the CSV option here will download a file containing the data shown in the graph Closing the graph After you have finished viewing the graph simply press the X close icon on the Graph Widget title bar bottom right Electricity Widget Live display of your current overall electrical energy consumption in Watts kW together with the current overall cost per hour based upon your Tariff settings The cost figure is adjusted for Solar PV generated power if applica ble Also shows electrical energy used cost for Today so far Yesterday Last 7 Days and Last 30 Days wi