Home

ADAM-5000 Series Manual.book

image

Contents

1. LED Q000000000000000 6 jumpers Q000000 Figure 6 12 Jumper Location on the ADAM 5080 Module 0000000000000000 00000000 TTL Input Level Isolated Input Level Figure 6 13 TTL Isolated Input Level Selection Table 6 1 ADAM 5080 Technical Specifications Channel 4 Input Frequency 0 3 1000 Hz max Frequency mode 5000 Hz max Counter mode Input Level Isolated or TTL level Minimum Pulse Width 500 u sec Frequency mode 100 u sec Counter mode Minimum Input Current 2mA Isolated Isolated Input Level Logic Level 0 1 Vw Logic Level 1 3 5 V to 30 V TTL Input Level Logic Level 0 0 V to 0 8 V Logic Level 1 2 3 to 5 V Isolated Voltage 1000 Vrus Mode Counter Up Down Bi direction Frequency Programmable Digital Noise 8 65000 u sec Filter 61 ADAM 5000 Series User Manual ADAM 5081 4 ch High Speed Counter Frequency Mode Selection Users can select Bi direction Up Down Counter or Frequency option as shown below Note This high speed module is only for ADAM 5550 Series and ADAM 5000 485 ADAM 5000E B BD 50 5024 fj 51 5013 b 5215018 Jf 53 5081 oma F Hr Alam Off LO Alam Off foooee Hl Alam Off LO Alam Off ooo O Hr Alam iX On LO Alam Off ooo O Hr Alam Ofi LO Alam Off Figure 6 14 Counter Frequency Mode Note All four channels of ADAM 5081 will oper
2. 16 DI ADAM 5051S 0 ITT x O OZ WLWOU AZOGODRD o o009000009 0000090000 N A LI Figure 4 9 ADAM 5051S Module Front View ADAM 5000 Series User Manual 36 Application Wiring 5 V Internal l External S I I Protection Circuit s Bi direction I DI Channel Figure 4 10 ADAM 5051S Module Wiring Diagram Table 4 3 Technical Specifications of ADAM 5051S Point 16 4 channel group Digital Input Logic Level 0 3 V max Logic Level 1 10 to 50 V Optical Isolation 2500 Voc Opto isolator response time 25 us Over voltage Protection 70 Voc Power Consumption 0 8 W LED Indicator On when active I O Connector Type 21 pin plug terminal 37 ADAM 5000 Series User Manual 4 1 4 ADAM 5052 8 ch Isolated Digital Input Module ADAM 5052 provides eight fully independent isolated channels All have 5000 Vrms isolation to prevent ground loop effects and to pre vent damage from power surges on the input lines ADAM 5052 a 8 Dl ADAM 5052 NZ IS 7 EJ EJ EJ EJ EJ CI i EJ CJ i CJ E al EJ El SE c gt c A j U Figure 4 11 ADAM 5052 Module Front View Application Wiring Points 3K Q Internal Logic
3. Off Clear L Latch Status START C STOP TEXT ka zj Clear Counter Digital filter scale 8765000 00050 us O Off Gear Counter Iritial value 0000000010 Alarm Type Alarm Limit DO Map Slot Channel High Latch 0000000050 7 Enable i IE Low Latch X Disable Update COM 2 3600 bps Polling current data 2001 9 19 AM 03 53 Figure 6 11 Digital Output Mapping High Alarm State Set Alarm state to Latch or Disable High Alarm Limit Set Alarm limit from O to 4 294 967 295 High Alarm Output Mode Enable or Disable D O Mapping High Alarm Output Slot Users can select D O Modules such as ADAM 5050 ADAM 5055 ADAM 5056 ADAM 5060 ADAM 5068 High Alarm Output Channel Select Alarm Output Channel 6 Clear Latch Alarm Users can select Enable or Disable option When selecting Enable the latch will be relieved and the alarm state will return to normal Once the alarm state returns to normal the Clear Latch Alarm will return to Disable A RNA S TTL Isolated Input Level According to your need you can select either TTL or Isolated Input Level by set ting the configuration for the jumpers Select the proper jumper settings for either TTL or Isolated Input according to Figure 53 Please note that you Must configure all six jumpers to the correct con figuration for proper function ADAM 5000 Series User Manual 60
4. 0s422444n nennen 6 Table 1 4 Technical Specifications of ADAM 5017 7 1 2 3 ADAM 5017P 8 ch Al with independent Input 7 Figure 1 7 ADAM 5017P Module Front View 8 Figure 1 8 Millivolt and Volt Input 8 Figure 1 9 Process Current Input eeeeeaaaee aaa nn ren rer 8 Table 1 5 Technical Specifications of ADAM 5017P 9 1 2 4 ADAM 5017H 8 ch High Speed Analog Input Module 9 Figure 1 10ADAM 5017H Module Front View 1221111 9 Figure 1 11Millivolt and Volt Input 10 Figure 1 12Process Current Input e esssaaaa aaa anna 10 Figure 1 13Locations of Jumpers e e eeee aaa aaa 10 Table 1 6 Technical Specifications of ADAM 5017H 11 Table 1 7 ADAM 5017H Input Signal Ranges 11 1 2 5 ADAM 5017UH 8 ch Ultra High Speed Analog Input Module 12 Figure 1 14ADAM 5017UH Module Front View 12 Figure 1 15Millivolt and Volt Input 12 Figure 1 16Process Current Input eseseaaa nnnnnennn nenn 12 Figure 1 17Locations of RC Filter Jumper Setting 13 Figure 1 18Locations of RC Filter Jumper Setting 13 Table 1 8 Technical Specifications of ADAM 5017UH 14 Table 1 9 ADAM 5017UH Input Sgnal Ranges 14 1 2 6 ADAM 5018 7 ch Thermocouple Inpu
5. I O Connector Type 21 pin plug terminal ADAM 5056 D 16 ch Digital Output Module w LED The ADAM 5056 features sixteen digital output channels The digital outputs are open collector transistor switches that you can control from the ADAM 5000 main unit You also can use the switches to control solid state relays ADAM 5056 DU Ss A 16 DO O ADAM 5056 1 OOOOOOOOO00000000 Figure 4 17 ADAM 5056 Module Frontal View 41 ADAM 5000 Series User Manual Application Wiring VSS Internal Logic SSR AC R2 limit current to 100 mA Collector Vss Power Ground Power Ground Figure 4 18 Digital Output with SSR ADAM 5050 5056 There are 16 point digital input and 16 point digital output modules in the ADAM 5000 series The addition of these solid state digital I O devices allows these mod ules to control or monitor the interfaces between high power DC or AC lines and TTL logic signals A command from the host converts these signals into logic levels suitable for the solid state I O devices Table 4 7 Technical Specifications of ADAM 5056 Points 16 Digital Output Open collector to 30 V 100 mA max load Power Dissipation 450 mW Power Consumption 0 25 W ADAM 5000 Series User Manual 42 4 1 8 ADAM 5056S 16 ch Isolated Digital Output Module with LED The ADAM 5056S provides 16 isolated digital output channels for critical environments need individual channel isolat
6. Table 1 6 Technical Specifications of ADAM 5017H Analog Input Channels 8 differential ADC Resolution 12 bits plus sign bit Type of ADC Successive approximation Isolation Voltage 3000 Voc Sampling Rate 100 Hz Input Impedance 2MQ voltage input 1200 current input Signal Input Bandwidth 1000 Hz for both voltage inputs and current inputs Analog Signal Range 15 V max Analog Signal Range for 15 V max any two measured Pins Power Requirements 10 to 30 VDC non regulated Power Consumption 1 8 W Accuracy 0 1 or better Table 1 7 ADAM 5017H Input Signal Ranges Input With Offset Offset Gain Gain Error Offset Drift Gain Display Range Over Error Error Error 10 Drift Resolution ranging 25 C 10 to 25 C To 70 C 70 C Voltage 0 10V O 11V 41 LSB 2 LSB 1 LSB 2 LSB 117 uV C 50 ppm 2 7 mV Inputs C 0 5V 10 55VI 1LSB 2LSB 1 5 2 LSB 116 uV C 50 ppm 1 3 mV LSB C 0 2 5V 0 2 75 1LSB 2LSB 1 5 2LSB 20 V C 55 ppm 0 67 mV V LSB C 0 1V 0 1 LSB 2 5 2 LSB 2 5 LSB 20 uV C 60 ppm 0 34 mV 1 375 V LSB C 0 500 0 5LSB 3 LSB 3 5 LSB 20uV C 67 ppm 0 16 mV mV 687 5 C mV 10V 11 V 1LSB 2LSB 1 LSB 2 LSB 17uV C 50 ppm 2 7 mV C 5V 0 5 5 1LSB 2LSB 1 5 2 LSB 17 VPC 50 ppm 1 3 mV V LSB C 25V 0 1 LSB 2 LSB 1 5 2 LSB 20 uV C 55 ppm 0 6
7. User Manual ADAM 5000 Series I O Modules DVANTECH eAutomation Copyright The documentation and the software included with this product are copyrighted 2008 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of t
8. 1 07h 4 20 mA 1 Note You can substitute 2 5 V for 20 mA if you remove the current conversion E resistor for that channel However the calibration accuracy will be lim ited to 0 1 due to the resistor s tolerance ADAM 5000 Series User Manual 28 3 1 2 Analog Output Module Calibration The output current of analog output modules can be calibrated by using a low calibra tion value and a high calibration value The analog output modules can be configured for one of two ranges 0 20 mA and 4 20 mA Since the low limit of the 0 20 mA range 0 mA is internally an absolute reference no power or immeasurably small power just two levels are needed for calibration 4 mA and 20 mA 1 2 Apply power to the ADAM 5000 system including the analog output module for about 30 minutes Assure that the module is correctly installed and that its configuration is accord ing to your specifications and that it matches the output range you want to cali brate You can do this by using the ADAM utility software Connect either a 5 digit mA meter or voltmeter with a shunt resistor 250 ohms 01 and 10 ppm to the screw terminals of the module Figure 3 2 Output Module Calibration Issue the Analog Data Out command to the module with an output value of4 mA Check the actual output value at the modules terminals If this does not equal 4 mA use the Trim option in the Calibrate submenu to change the actual out put Trim the
9. 28 Table 3 4 Calibration Voltage of ADAM 5017UH 28 Analog Output Module Calibration uee ener renee 29 Figure 3 2 Output Module Calibration 29 Chapter 4 Digital Input Output Modules 31 4 1 Digital Input Output Modules sssese eee ee ae aa aaa LEE nn 32 4 1 1 ADAM 5050 16 ch Universal Digital I O Module 32 Figure 4 1 DIP Switch Setting for Digital I O Channel 32 Figure 4 2 ADAM 5050 Module Frontal View 32 Figure 4 3 Dry Contact Signal Input ADAM 5050 33 Figure 4 4 Wet Contact Signal Input ADAM 5050 33 Figure 4 5 Digital Output with SSR ADAM 5050 5056 33 Table 4 1 Technical Specifications of ADAM 5050 34 4 1 2 ADAM 5051 D 16 ch Digital Input Module 34 Figure 4 6 ADAM 5051 Module Frontal View 34 Figure 4 7 TTL Input ADAM 5051 5051D 35 Figure 4 8 Contact Closure Input ADAM 5051 5051D 35 4 1 5 4 1 7 4 1 10 Table 4 2 Technical Specifications of ADAM 5051 5051D 36 ADAM 5051S 16 ch Isolated Digital Input Module with LED 36 Figure 4 9 ADAM 5051S Module Front View 36 Figure 4 10ADAM 5051S Module Wiring Diagram
10. ADAM 5095 DTE Pin Wiring Pin ADAM 5095 DTE DB9 M Pin Signal DTE Pin Signal 7 CAN H CAN H 3 GND GND 2 CAN L CAN L Maximum Bit Rate vs Bus Length For a Controller Area Network the maximum possible bus length depends on the bit rate The bit rate can always be slower than the maximum possible speed for a given bus length Conversely the bus length can be shorter than the maximum possible bus length for a given transmission speed Table 7 9 Maximum Bit rate vs Bus Length Bit Rate Bus Length 1M bps 25m 800k bps 50m 500k bps 100m 250k bps 250m 125k bps 500m 50k bps 1000m 20k bps 2500m 10k bps 5000m 79 ADAM 5000 Series User Manual ADAM 5000 Series User Manual 80 Chapter 8 Storage Modules 8 1 Storage Modules 8 1 1 Compatible ADAM 5000 Series Main Units The ADAM 5030 is a 2 slot SD storage module to be implemented with the following Advantech ADAM 5000 series main units ADAM 5030 SD Storage Module The ADAM 5030 storage module provides 2 slot of SD cards When you insert the SD card into the ADAM 5030 please remove the name plate first Please be careful to remove it If you remove it with great exertion it may be damaged ADAM 5030 Diagram 2SD 2USB O ADAM 5030 Figure 8 1 ADAM 5030 Module Frontal View Table 8 1 Technical Specifications of ADAM 5030 USB Type USB Rev 2 0 Compliant USB Numb
11. Get your host PC ready and run the ADAM 5510 Utility Software Step 2 Install the ADAM 5090 Module and power on your ADAM 5510 main unit Step 3 Download the executable program to the main unit Step 4 Monitor the ADAM 5090 Module s current status from the PC through the util ity software A basic example program for the ADAM 5090 main IInstall the port you would like to use Here we install slot 0 port 1 port_install 1 I Here we install slot 2 port 2 port_install 22 Select working port Here we select slot 0 port 1 port_select 1 Set port data format Here we set the data format of port 1 as lengh 8 parity 0 stop_bit 1 N81 port_set_format 1 8 0 1 Set port speed Here we set communication speed of port 1 as 115200 bps L is necessary port_set_speed 1 115200L Enable Port FIFO Here we enable 128 byte FIFO for port 73 ADAM 5000 Series User Manual port enable fifo 1 After these above settings are enabled you can apply any other function library to implement your program A receive and transmit example program for the ADAM 5090 main int err_value char character port_installed 1 port enable fifo 1 check whether error has been received or not err_value port_rx_error 1 Ilif error detected print out the message if err_value printf n Rx Error The LSR Value 02X Err_value licheck whether FIFO receives data or no
12. 0 30 Voc Ea Figure 4 12 Isolation Digital Input ADAM 5052 Table 4 4 Technical Specifications of ADAM 5052 8 Differential Digital input Logic level 0 1 V max Resistance 3 k 0 5 W Logic level 1 3 5 to 30 V Isolation voltage 5000 V Rus Power consumption 0 4 W ADAM 5000 Series User Manual 4 1 5 ADAM 5053S 32 ch Isolated Digital Input Module The ADAM 5053S provides 32 isolated digital input channels for critical environ ments need individual channel isolating protection Different from other ADAM 5000 I O modules ADAM 5053S designed with 40 pin flat cable wiring terminal 32 DI ADAM 5053S Channel 0 Figure 4 13 ADAM 5053S Module Front View Application Wiring T COM 1 Ly SU a a ean Te Fee ICncncncH chchCnch gt I OL 03 05 07 LD 15 7 9 11 13 15 17 1 CHChCHCh ChchChich 00 02 D D6 08 10 12 14 COM 1 ADAM 50538 Digital Input Wiring J OR DI Chanae kK ap Aa 10V 30V m Figure 4 14 ADAM 5053S Module Wiring Diagram Table 4 5 ADAM 5053S Technical Specifications Point 32 Digital Input Logic Level 0 5 V max Logic Level 1 19 to 35 V Optical Isolation 2500 VDC Opto isolator response time 25 us Over voltage Protection 35 VDC Power Consumption 1 W max I O Connector Type 40 pin flat cable wiring terminal 39 ADAM 5000 Series User Manual 4 1 6 A
13. 19 ADAM 5018 Module Front View Application Wiring T C Figure 1 20 Thermocouple Input 15 ADAM 5000 Series User Manual Table 1 10 Technical Specifications of ADAM 5018 Analog Input Channels Seven differential Input Type mV V MA Thermocouple Input Range 15 mV 50 mV 100 mV 500 mV 1 V 2 5 V and 20 mA T C Type and J 0 to 760 C Temperature Range K 0 to 1370 C T 100 to 400 C E 0 to 1400 C R 500 to 1750 C S 500 to 1750 C B 500 to 1800 C Isolation Voltage 3000 VDC Sampling Rate 10 samples sec total Input Impedance 2MQ Bandwidth 13 1 Hz Q 50 Hz 15 72 Hz 60 Hz Accuracy 0 1 or better Zero Drift 0 3 uV C Span Drift 25 PPM C CMR 50 60 Hz 92 dB min Power Consumption 1 2W 1 2 7 ADAM 5018P 7 ch Thermocouple Input Module The ADAM 5018P is a 16 bit 8 channel Thermocouple Independent input module that provides programmable input ranges on all channels It accepts Various Thermo couple inputs Type J K T E R S B and provides data to the host computer in engineering units C In order to satisfy various temperature requirements in one module each analog channel is allowed to configure an individual range for several applications ES RS R ND 7 TC O ADAM 5018P 1 w jg vi ej c vi kj v2 5 V2 8 Fr OFS z v3 8 va g CI va lg J V5 o 7 vs g vr loy
14. 2 Printed in Taiwan April 2013 ADAM 5000 Series User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FM This equipment has passed the FM certification According to the National Fire Pro tection Association work sites are classified into different classes divisions and groups based on hazard considerations This equipment is compliant with the speci fications of Class I Division 2 Groups A B C and D indoor hazards Technical Support and Assistance 1 Visit the Advantech web site at www advantech co
15. 37 Table 4 3 Technical Specifications of ADAM 5051S 37 ADAM 5052 8 ch Isolated Digital Input Module 38 Figure 4 11ADAM 5052 Module Front View 38 Figure 4 121solation Digital Input ADAM 5052 38 Table 4 4 Technical Specifications of ADAM 50322 38 ADAM 5053S 32 ch Isolated Digital Input Module 39 Figure 4 13ADAM 5053S Module Front View 39 Figure 4 14ADAM 5053S Module Wiring Diagram 39 Table 4 5 ADAM 5053S Technical Specifications 39 ADAM 5055S 16 ch Isolated Digital I O Module with LED 40 Figure 4 15ADAM 5055S Module Front View 40 Figure 4 16ADAM 5055S Module Wiring Diagram 40 Table 4 6 Technical Specifications of ADAM 5055S 41 ADAM 5056 D 16 ch Digital Output Module w LED 41 Figure 4 17ADAM 5056 Module Frontal View 41 Figure 4 18Digital Output with SSR ADAM 5050 5056 42 Table 4 7 Technical Specifications of ADAM 5056 42 ADAM 5056S 16 ch Isolated Digital Output Module with LED 43 Figure 4 19ADAM 5056S Module Front View 43 Figure 4 20ADAM 5056S Module Wiring Diagram 44 Table 4 8 Technical Specifications of ADAM 5056S 44 ADAM 5056S0 16 ch Isolat
16. O to 600 C A 0 00385 440 Ohms 60 Ohms 24 Pt 100 to 100 C A 0 00392 140 Ohms 60 Ohms 25 Pt O to 100 C A 0 00392 140 Ohms 60 Ohms 26 Pt O to 200 C A 0 00392 200 Ohms 60 Ohms 27 Pt O to 600 C A 0 00392 440 Ohms 60 Ohms 28 Ni 80 to 100 C 200 Ohms 60 Ohms 29 Ni O to 100 C 200 Ohms 60 Ohms 5 ADAM 5000 Series User Manual 1 2 2 ADAM 5017 8 ch Analog Input Module The ADAM 5017 is a 16 bit 8 channel analog differential input module that provides program mable input ranges on all channels It accepts mill volt inputs 150mV 500mV voltage inputs 1V 5V and 10V and current input 20 mA The module provides data to the host computer in engineering units mV V or mA This module is an extremely cost effective solu tion for industrial measurement and monitoring applications Its opto isolated inputs provide 3 000 Voc of isolation between the analog input and the module protecting the module and peripherals from damage due to high input line volt age Additionally the module uses analog multiplexers with active over voltage protection The active protection circuitry assures that signal fidelity is maintained even under fault conditions that would destroy other multiplex ers This module can withstand an input voltage surge of 70 Vp p with 15 V supplies The jumpers of ADAM 5017 are designed for current input ADAM 5017 DAODAODLODADDADD Figure 1 4 ADAM 5017 Module Front View Application Wi
17. initial value Furthermore if users want to check the counter value to see if it is higher or lower than the Max Min value they can use the ReadOverflowFlag library to gain readout of the over flow value Getting the Totalizer Value If users want to get the actual counter value a formula such as follows can facilitate an easy calculation from the initial counter value overflow value and current counter value Viol Vini Vmin or Vmax 1 x Vv Vini Vcur Viol totalizer value Vini initial counter value V min min counter value 0 fixed value Vmax max counter value 2 4 294 967 295 fixed value Vvf overflow value Vcur current counter value Example If the initial value 10 overflow value 4 min value 0 current counter value 3 the totalizer value could be Totalizer value 10 O 1 x 4 10 3 51 59 ADAM 5000 Series User Manual Features Digital Output Mapping If users want to use Digital Output function ADAM utility is available for setting specif ically which module channel or slot to receive the alarm signals 5 x File Tools Help o ale a ANS PC r ADAM 5080 Channel 0 g COM1 E COM2 Filii 00 5000 cz 50 5024 r General Setting 51 5013 i 52 5018 Input Range Erdiection counter 53 5080 Data Format Fe CHO CH1 CH 2 Channel Setting CH 3 Reading GOA H Alam L Alam Clear H Latch Bor
18. module until the mA meter indicates exactly 4 mA or in case of a voltage meter with shunt resistor the meter indicates exactly 1 V When calibrating for 20 mA using a voltage meter and shunt resistor the correct voltage should be 5V Issue the 4 mA Calibration command to indicate that the output is calibrated and to store the calibration parameters in the module s EEPROM Execute an Analog Data Out command with an output value of 20 mA The module s output will be approximately 20 mA Execute the Trim Calibration command as often as necessary until the output cur rent is equal to exactly 20 mA Execute the 20 mA Calibration command to indicate that the present output is exactly 20 mA The analog output module will store its calibration parameters in the unit s EEPROM 29 ADAM 5000 Series User Manual ADAM 5000 Series User Manual 30 Digital Input Output Modules 4 1 Digital Input Output Modules 4 1 1 ADAM 5050 16 ch Universal Digital I O Module The ADAM 5050 features sixteen digital input output channels Each channel can be independently configured to be an input or an output channel by the setting of its DIP switch The digital outputs are open collector transistor switches that can be controlled from the ADAM 5000 The switches can also be used to control solid state relays which in turn can control heaters pumps and power equipment The ADAM 5000 can use the module s digital inputs to determine the state of limit or saf
19. operate in Counter Mode Features Counter Mode Up Down Counting The Up Down Counter Function offers two types of counting Up Counting increas ingly and Down Counting decreasingly Up Counting when COA and COA sense any input signals the counter counts up Down Counting when COB and COB sense any input signals the counter counts down On receiving Up and Down signal simultaneously the counter will not perform each specific counting accordingly but will remain at the previous counting value since these simultaneous signals won t have any effect on counting values ADAM 5000 Series User Manual 56 COA COA COB D COB D Figure 6 5 Wiring for Up Down Counting If you need only one type of counting connect COA and COA for Up Counting only or connect COB and COB for Down JE Counting only Bi direction Counting For implementing Bi direction Counting you need to connect COB D and COB D to implement the control function for Up Down Counting Up Counting when the input sig nal is within logic level 1 the counter value increases COA COA CoB D CoB D Figure 6 6 Wiring for Bi direction Counting Down Counting when the input signal is within logic level 0 the counter value decreases Note Ifusers select TTL mode and don t connect COB COB the counter a value will increase If users select Isolated mode and don t connect B COB COB the counter value
20. output by switching the jumper and the maximum current output is 400mA 71 ADAM 5000 Series User Manual I O Slots and I O Ports Numbering The ADAM 5090 module provides four RS 232 ports for communication with target devices The ports are numbered 1 through 4 For programming the definition of port number depends on the slot number and port number For example the second port on the ADAM 5090 in slot 1 is defined to port 12 Jumper Settings This section tells you how to set the jumpers to configure your ADAM 5090 module There are four jumpers on the PC Board User can choose RI signal or 5V output for each port by setting these jumpers system default is RI signal The following figure shows the location of the jumpers Port Port2 Port3 Port4 Figure 7 3 Jumper Locations on the CPU Card Ji J2 J3 J 2 2 2 2 i e Le R 5V Output RI Signal Default Figure 7 4 Jumper Settings ADAM 5000 Series User Manual 72 LED Status of the ADAM 5090 Module There are two LEDs for each port on the front panel ofthe ADAM 5090 to display spe cific communication status M Green LED RX Data Receiving Status the LED indicator is on when the port is receiving data m OrangeLED TX Data Transmitting Status the LED indicator is on when the port is transmitting data Configuring Your ADAM 5090 Module This section explains how to configure an ADAM 5090 module before implementing it into your application Quick Start Step 1
21. will decrease Features Frequency Mode If users want to select frequency mode they can only utilize Up Counting type and can only connect to COA and COA 57 ADAM 5000 Series User Manual COA COA C0B D CoB D Figure 6 7 Wiring for Frequency Mode Features Alarm Setting According to your application purposes you can run the utility program to set different limit values for High Low Alarm Figure 6 8 Setting Alarm Limit Setting Initial Counter Value In order to utilize the alarm users have to set a high alarm limit value and or a low alarm limit value and a initial value to fulfill the requirements for a basic alarm setting ADAM 5000 Series User Manual 58 Max value Sending High alarm High alarm limi Initial value endi la e eels Low alarm limit w Min value Figure 6 9 Sending Alarm Signal Recommended Settings Max value Initial value Sending High alarm High alram Initial value Sending low alarm Low alarm limit value Min value Figure 6 10 Sending Alarm Signal Not Recommended Overflow Value Overflow value is the number of times the counter value exceeds the Max Min val ues you specified When the counter value exceeds Maxi mum value the overflow value increases when the counter value goes under Minimum value the overflow value decreases Besides when the counter value runs beyond the range of Max Min value it will continue counting from the
22. x File Tools Help ol aaia el Sl r ADAM 5081 Channel 0 Aiii 00 5000 EH 50 5024 General Setting EH 1 5013 f E 2 5018 Input Range Bidirection counter E A Da a Format Hex CH 1 z CH 2 Channel Setting CH 3 k Reading oa Hz sm L Alam Clear H Latch Off Off Clear L Latch Status START STOP TEXT Clear Counter Digital filter scale 8765000 00050 us Off est Counter Initial value 0000000010 Alarm Type Alarm Limit DO Map Slot Channel High flach 000000006 au Low jLatch z Update COM 2 3600 bps Polling current data 2001 8719 AM 08 53 Figure 6 21 Digital Output Mapping High Alarm State Set Alarm state to Latch or Disable High Alarm Limit Set Alarm limit from O to 4 294 967 295 High Alarm Output Mode Enable or Disable D O Mapping High Alarm Output Slot Users can select D O Modules such as ADAM 5050 ADAM 5055 ADAM 5056 ADAM 5060 ADAM 5068 for the alarm signal to be sent through High Alarm Output Channel Select Alarm Output Channel 6 Clear Latch Alarm Users can select Enable or Disable option When selecting Enable the latch will be relieved and the alarm state will return to normal Once the alarm state returns to normal the Clear Latch Alarm will return to Disable AUN S M TTL Isolated Input Level According to your need you can select either TTL or Isolated Input Level by set ting the configuration for the jumpers S
23. 0 W 51 ADAM 5000 Series User Manual ADAM 5069 Relay Output Module The ADAM 5069 relay output module provides 8 relay channels of Form A Switches can be used to control the relays Considered to user friendly the ADAM 5069 also built with LED indicator for status reading easily And it also provides a choice to clear or keep output status when reset by adjusting a jumper Specifications Number of Output Channel 8FormA Contact Rating AC 250VQ5A DC 30VQ5A Breakdown Voltage 750 VAC 50 60 Hz Insulation Resistance 1000M Q500VDC LED Indicator On Active Off Non active Power Consumption 0 25W typical 2 2W Max Isolation Resistance 4000 VRMS Relay response Time On 5 ms Off 5 6 ms Clear or Keep Relay Status when reset selectable by jumper 8 Power Relay O ADAM 5069 O00000000500000 Figure 5 5 ADAM 5069 Module Front View Wiring ADAM 5000 Series User Manual 52 Counter Frequency Modules 6 1 Counter Frequency Modules Compatible ADAM 5000 Series Main Units ADAM 5080 is a 4 channel counter frequency module designed to be implemented within the following Advantech ADAM 5000 series main units ADAM 5000 485 ADAM 5510 ADAM 5511 ADAM 5510M ADAM 5510E ADAM 5510 TCP ADAM 5510E TCP Note Please make sure that the ADAM 5080 counter frequency module is E properly inserted into the compatible main units 6 1 1 ADAM 5080 4 ch Counter Frequency Module With AD
24. 017H 8 ch High Speed Analog Input Module ADAM 5017H is an 8 ch analog differential input module that provides programmable input ranges on each channel The module provides data to the host microprocessor in engineering units mV V or mA or two s complement format Its sampling rate depends on the data format received up to 100 Hz total Each input channel has 3000 VDC of optical isolation between the outside analog input line and the module protecting the module and peripherals from high input line voltages Additionally the module uses analog multiplexers with active over voltage protection The active pro tection circuitry assures that signal fidelity is maintained even under fault conditions that would destroy other multiplexers The analog inputs can withstand a constant 70 Vp p input with 15V supplies ADAM 5017H O ADAM 5017H J lt 22222223 E 00000000000000 PZP i Figure 1 10 ADAM 5017H Module Front View 9 ADAM 5000 Series User Manual Application Wiring Figure 1 12 Process Current Input JP2 e o o e eje o eje ee ES Peje mp FR gt JP1 29092000 ao GG 009009006 aoaocoocoeae EEE Figure 1 13 Locations of Jumpers Note To maintain measurement accuracy pleases short channels not in use E ADAM 5000 Series User Manual 10
25. 1 Table 3 2 Calibration Voltage ADAM 5017H Module Input Range Input Range Span Calibration Code Hex Voltage 5017H 00h 10 V 10 V 01h 0 10V 10 V 02h 5 V 5 V 03h 0 5V 5 V 04h 2 5 V 2 5 V 05h 0 2 5V 2 5 V 06h 1 V 1 V 07h 0 1V 1 V 08h 500 mV 500 mV 09h 0 500 mV 500 mV Oah 4 20 mA 1 Obh 0 20 mA 1 Note You can substitute 2 5 V for 20 mA if you remove the current conversion resistor for that channel However the calibration accuracy will be lim ited to 0 1 due to the resistor s tolerance B 27 ADAM 5000 Series User Manual Table 3 3 Calibration Voltage of ADAM 5018P Module Input Range Input Range Span Calibration Code Hex Voltage 5018P 00h 15 mV 15 mV 01h 50 mV 50 mV 02h 100 mV 100 mV 03h 500 mV 500 mV 04h 1 mV 1V 05h 2 5 V 2 5 V 06h 20 mV 20 mA 1 07h 4 20 mA 16 mA 1 OEh J thermocouple 0 to 1370 C 50 mV OFh K thermocouple 0 to 1370 C 50 mV 10h T thermocouple 100 to 400 C 22 mV 11h E thermocouple 0 to 1000 C 80 mV 12h R thermocouple 500 to 1750 C 22 mV 13h S thermocouple 500 to 1800 C 22 mV 14h B thermocouple 500 to 1800 C 152 mV Table 3 4 Calibration Voltage of ADAM 5017UH Module Input Range Code Input Range Span Calibration Hex Voltage 5017H 08h 10 V 10 V 48h 0 10V 10 V 46h 0 20 mA
26. 22 22 33 33 66 66 133 33 266 66 533 33 Communication Backup Function With the ADAM 5090 you can implement dual communication channels between your PC and the ADAM system Even when one of the two communication channels is down your system can still function through the alternative communication channel This dual communication channels can be implemented by application software ADAM 5090 Module Diagram 4 RS232 Q ADAM 5090 Porti Port2 Port3 Port4 Figure 7 1 ADAM 5090 Module ADAM 5000 Series User Manual 70 ADAM 5090 Application Wiring RJ 48 ORO RS 232 Device Communication Cable 3 2 00 R 3g 00 x 00 oo CEER Figure 7 2 ADAM 5090 Application Wiring Table 7 2 Pin Mapping PIN Name RJ 48 DB9 IDCD RX TX IDTR GND IDSR IRTS ICTS RI or 5V GND gt l lolo Solo ron xolo nola ron Table 7 3 ADAM 5090 Technical Specifications Function Provides communication ports for the ADAM 5510 to integrate other devices with communication function into your system Electrical Interface 4 ports RS 232 Communication Rates 4800 9600 19200 38400 115200bps FIFO 128 bytes per UART Tx Rx Indicator Tx Orange Rx Green Power Required 100mA 5Voc Default in RI mode User can define the communication ports with 5VDC
27. 65 Figure 6 20Sending Alarm Signal Not Recommended 65 Figure 6 21Digital Output Mapping ss0222444sene ns nnnennnen nn 66 Figure 6 22 Jumper Location on the ADAM 5081 Module 67 Figure 6 23TTL Isolated Input Level Select 67 Table 6 2 ADAM 5081 Technical Specifications 67 Serial Modules 1 1 O9 serlal M dules rasen ky Aa ak 70 7 1 1 ADAM 5090 4 port RS 232 Communication Module 70 Table 7 1 Baud Rate SettingS eeeeeuaaa aaa aaa sene 70 Figure 7 1 ADAM 5090 Module essuuaaaa nnnnnnn nenn 70 Figure 7 2 ADAM 5090 Application Wiring 71 Table 7 2 Pin Mapping eee ee ee ea aaa aaa aaa aaa eaanaaanaa 71 Table 7 3 ADAM 5090 Technical Specifications 71 Figure 7 3 Jumper Locations on the CPU Card 72 Figure 7 4 Jumper Settings u u u dcsseeenseesekeeessnnnesnsn sneen sene nnnnee 72 7 1 2 ADAM 5091 4 port RS 232 Communication Module 75 Table 7 4 Baud Rate SettingS eeeeuaaaa aaa aiaea 75 Figure 7 5 ADAM 5091 Module ssssueeaa aaa aaaaaaaaci 75 Figure 7 6 ADAM 5091 Application Wiring 76 Table 7 5 PIN Mapping see e eee ea aaa aaa aaa aaa nennen 76 Table 7 6 ADAM 5091 Technical Spe
28. 7 mV 2 75 V LSB C 1V 0 1LSB 2 5 2 LSB 2 5 LSB 20 uV C 60 ppm 0 34 mV 1 375 V LSB C 500 mV 0 5 LSB 3 LSB 3 5 LSB 20 uV C 67 ppm 0 16 mV 687 5 C mV Current 0 20 mA 22mA 1LSB 1LSB 1 5 2 LSB nA C ppm C 5 3 u Inputs LSB 4 20 mA 22 mA 1LSB 1LSB 15 2 LSB nA C ppm C 5 3 u LSB 11 ADAM 5000 Series User Manual 1 2 5 ADAM 5017UH 8 ch Ultra High Speed Analog Input Module The ADAM 5017UH is a 12 bit plus sign bit 8 channel analog differential input module that pro vides programmable input ranges on each channel It accepts voltage inputs 10 V and 0 10 V and current inputs 0 20 mA and 4 20 mA The module provides data to the host microprocessor in engineering units mV V or mA or two s complement format Its sampling rate depends on the data format received up to 200k Hz total Space is reserved for 125 ohm 0 1 10 ppm resistors See Figure 9 Each input channel has 3000 Voc of optical isolation between the outside analog input line and the module protecting the module and peripherals from high input line voltages Additionally the module uses analog multiplexers with active overvoltage pro tection The active protection circuitry assures that signal fidelity is maintained even under fault conditions that would destroy other multiplexers The analog inputs can withstand a con stant 70 Vp p input with 15V supplies The jumpers of ADAM 5017UH a
29. AM 5080 4 Channel Counter Frequency Module users can select either counter or frequency mode for data output ADAM 5080 offers users a variety of very flexible and versatile applications such as below Counter Mode or Frequency Mode If you want to measure the number of input signals for totalizer function you may use counter mode to measure quantities such as movement and flow quantity Alternatively you can also select frequency mode to calculate the instantaneous differential of quantities such as rotating speed frequency or flow rate and present them in specific engineering formats Up Down or Bi direction Function When operating in counter mode you can choose either the Up Down function or the Bi direction function for different application purposes The counter will count up or down according to your applications This counting function helps users obtain the most accurate data Alarm Setting Function While in counter mode you can set alarm status Disable and Latch If you want to disable it you can select Disable If Latch status is selected it means the Alarm status will be latched whenever the alarm is being triggered Once the alarm status being latched it will thereafter stay in that triggered state Users will have to issue a Clear Alarm Status command to return the latched alarm status back to normal Users can designate the high limit value and low limit value to regulate your alarm behavior through the utility
30. Backup Function With the ADAM 5091 you can implement dual communication channels between your PC and the ADAM system Even when one of the two communication channels is down your system can still function through the alternative communication channel This dual communication channels can be implemented by application software ADAM 5091 Module Diagram 4 RS232 ADAM 5091 o Porti O Port2 o Port3 o Port4 Figure 7 5 ADAM 5091 Module 75 ADAM 5000 Series User Manual ADAM 5091 Application Wiring RJ 48 GOES RS 232 Device Communication Cable Figure 7 6 ADAM 5091 Application Wiring PIN Mapping Table 7 5 PIN Mapping PIN Name RJ 48 DB9 DCD RX TX DTR GND DSR IRTS ICTS RI or 5V GND a jojo Nlola A w p x iojlo uvlo a Alw p Table 7 6 ADAM 5091 Technical Specifications Function Provides communication ports for the ADAM 5550 to integrate other devices with communication function into your system Electrical Interface 4 ports RS 232 Communication Rates 4800 9600 19200 38400 115200bps FIFO 128 bytes per UART Tx Rx Indicator Tx Green Rx Red Power Required 100mA Q 5Voc Default in RI mode ADAM 5000 Series User Manual 76 I O Slots and I O Port Numbering The ADAM 5091 module provides four RS 232 ports for communication with target devices For more in
31. Chapter 5 Relay Output Modules 5 1 Relay Output Modules 5 1 1 ADAM 5060 Relay Output Module The ADAM 5060 relay output module is a low cost alternative to SSR modules It pro vides 6 relay channels two of Form A and fourof Form C ADAM 5060 6 Relay O ADAM 5060 maa w Figure 5 1 ADAM 5060 Module Frontal View Application Wiring NO Form A Cc NO NC NO Form C C Figure 5 2 Relay Output Table 5 1 Technical Specifications of ADAM 5060 Points 6 two Form A and four Form C Contact rating AC 125 V 0 6A 250 V 0 3 A DC 30VQ 2A 110VQ0 6A Breakdown voltage 500 Vac 50 60 Hz Relay on time typical 3 ms Relay off time typical 1ms Total switching time 10 ms Insulation resistance 1000 M min 500 Voc Power consumption 0 7 W ADAM 5000 Series User Manual 50 ADAM 5068 Relay Output Module The ADAM 5068 relay output module provides 8 relay channels of Form A Switches can be used to control the solid state relays ADAM 5068 8 Relay O ADAM 5068 Figure 5 3 ADAM 5068 Module Front View Application Wiring NO Form A C MO Figure 5 4 Relay Output Table 5 2 Technical Specifications of ADAM 5068 Points 8 Form A Contact Rating AC 120 V 0 5ADC 30V 1A Breakdown Voltage 500 Vac 50 60 Hz Relay On Time typical 7 msec Relay Off Time typical 3 msec Total Switching Time 10 msec Power Consumption 2
32. Configuration EH 1000 50 ADAM g wA 501760 Save Lo Ea 5017 81 wa WB 5017862 a 5017UH63 iil ra 50184 zo sm ii 24 15015455 CIC calibratio 1 Lg Others i i EJ ADAM4500_5510Series CIC temperature Input CIC offset 99 9 99 9C Apply Note Zero calibration and span calibration must be completed before CJC calibration To calibrate CJC the thermocouple attached to ADAM 5018 and a standard thermometer should be used to measure a standard known temperature such as the freezing point of pure water The amount of offset between the ADAM 5018 and the standard thermome ter is then used in the ADAM utility to complete CJC calibration ADAM 5000 Series User Manual 26 Table 3 1 Calibration Voltage of ADAM 5017 5018 Module Input Range Input Range Span Calibration Code Hex Voltage 5018 00h 15 mV 15 mV 01h 50 mV 50 mV 02h 100 mV 100 mV 03h 500 mV 500 mV 04h 1 mV 1 V 05h 2 5 V 2 5 V 06h 20 mV 20 mA 1 OEh J thermocouple 0 to 1370 C 50 mV OFh K thermocouple 0 to 1370 C 50 mV 10h T thermocouple 100 to 400 C 22 mV 11h E thermocouple 0 to 1000 C 80 mV 12h R thermocouple 500 to 1750 C 22 mV 13h S thermocouple 500 to 1800 C 22 mV 14h B thermocouple 500 to 1800 C 152 mV 5017 07h Not used 08h C 10 V 10 V 09h 5 V 5 V OAh 1 V 1 V OBh 500 mV 500 mV OCh 150 mV 150 mV ODh 20 mA 20 mV
33. DAM 5055S 16 ch Isolated Digital I O Module with LED The ADAM 5055S provides 8 isolated digital input and 8 isolated output channels for crit ical environments need individual channel isolating protection Different from other ADAM 5000 I O modules ADAM 5055S designed with 21 pins plug terminal Sy 16 DIO ADAM 5055S GNDO DOO DO1 D02 D03 D04 DOS DO6 DO7 COMO COM 1 DIO DI1 DI2 DI3 COM 2 DI4 DI5 DI6 DI7 N A Sl See Figure 4 15 ADAM 5055S Module Front View ADAM 5055S Application Wiring 5 V Internal External l 5 V DI Channel Circuit Figure 4 16 ADAM 5055S Module Wiring Diagram ADAM 5000 Series User Manual 40 4 1 7 Table 4 6 Technical Specifications of ADAM 5055S Points 16 Digital Output 8 8 channel group Open collector to 40 V 200 mA max load per channel Optical Isolation 2500 Voc Opto isolator response time 125 us Supply Voltage 5 40 Voc Digital Input 8 4 ch group Dry Contact Logic Level 0 open Logic Level 1 close to GND Wet Contact Logic Level 0 3 V max Logic Level 1 10 to 50 V Dry Contact amp Wet contact Selectable Optical Isolation 2500 Voc Opto isolator response time 25 us Over voltage Protect 70 Voc Power Consumption 0 68 W LED Indicator On when active
34. Frequency Module 54 Figure 6 1 ADAM 5080 Module esssuaaaaaa asa saaaaaacci 55 Figure 6 2 Isolated Input Level sseaaaa aaa aaaaaaaai 55 Figure 6 3 TTL Input Level 5 su2ee esssuaeaea aaa naeaaiena 55 Figure 6 4 Counter Frequency Mode 1 2 1 56 Figure 6 5 Wiring for Up Down Counting 4sees nennen 57 Figure 6 6 Wiring for Bi direction Counting 57 Figure 6 7 Wiring for Frequency Mode n 58 Figure 6 8 Setting Alarm Limit eee aaa aaa aaa anna 58 Figure 6 9 Sending Alarm Signal Recommended Settings 59 Figure 6 10Sending Alarm Signal Not Recommended 59 Figure 6 11Digital Output Mapping 0224444Henes sn nnnnnnen nn 60 Figure 6 12Jumper Location on the ADAM 5080 Module 61 Figure 6 13TTL Isolated Input Level Selection 61 Table 6 1 ADAM 5080 Technical Specifications 61 Figure 6 14 Counter Frequency Mode 1 62 Figure 6 15Wiring for Up Down Counting ser sn 63 Figure 6 16Wiring for Bi direction Counting re 63 Figure 6 17Wiring for Frequency Mode 221111422 64 Figure 6 18Setting Alarm Limit uueeea nennen snnnnnnen nn 64 Figure 6 19Sending Alarm Signal Recommended Settings
35. M 5090 4 port RS232 Non isolated ADAM 5091 4 port RS232 with Share Interrupt Non isolated ADAM 5095 2 port CAN Isolated Storage ADAM 5030 2 slot SD Storage Module Motion ADAM 5202 2 port AMONet Master Module ADAM 5000 Series User Manual 1 2 Analog Input Modules Analog input modules use an A D converter to convert sensor voltage current ther mocouple or RTD signals into digital data The digital data is then translated into engi neering units The analog input modules protect your equipment from ground loops and power surges by providing opto isolation of the A D input and transformer based isolation up to 3 000 Voc 1 2 1 ADAM 5013 3 ch RTD Input Module The ADAM 5013 is a 16 bit 3 channel RTD input module that features programmable input ranges on all channels This module is an extremely cost effective solution for industrial mea surement and monitoring applications Its opto isolated inputs provide 3 000 Vbc of isolation between the analog input and the module protecting the module and peripherals from dam age due to high input line voltage Note Due to the conversion time required by the A D converter the initializa N tion time of each ADAM 5013 module is 5 seconds Thus the total initial ization time will be about 20 seconds if all 4 I O slots in an ADAM 5000 main unit contain ADAM 5013 modules R ZOE 3 RTD O ADAM 5013 1 EXCO SEND SEND EXCO AGND EXC1 SEN1 SEN1 EXC1 AGND EXC2 SEN2
36. M utility software to help in this Connect the correct reference self resistance between the screw terminals of the ADAM 5013 as shown in the following wiring diagram Table 2 below shows the correct values of the span and zero calibration resistances to be connected Ref erence resistances used can be from a precision resistance decade box or from discrete resistors with the values 60 140 200 and 440 ohms Resistance Decade Box Figure 1 3 Applying Calibration Resistance First with the correct zero offset calibration resistance connected as shown above issue a Zero Calibration command to the module using the Calibrate option in the ADAM utility software Second with the correct span resistance connected as shown above issue a Span Calibration command to the module using the Calibrate option in the ADAM utility software Note that the module zero calibration must be completed prior to the span calibration Note Ifthe above procedure is ineffective the user must first issue an RTD R Self Calibration command aaSi2 to the module and then complete steps 4 and 5 after self calibration is complete Table 1 3 Calibration Resistances of ADAM 5013 Input Range Input Range Span Calibration Zero Calibration Code Hex Resistance Resistance 20 Pt 100 to 100 C A 0 00385 140 Ohms 60 Ohms 21 Pt O to 100 C A 0 00385 140 Ohms 60 Ohms 22 Pt O to 200 C A 0 00385 200 Ohms 60 Ohms 23 Pt
37. ROLLED ENVIRONMENT CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein ADAM 5000 Series User Manual iv Chapter Chapter Chapter 1 1 1 1 2 2 2 1 3 3 1 Overview sussasosanonanananacanaczazazazanczcnawa 1 Introduetion eee ae odzie darek aa 2 Table 1 1 Supported I O Module List en 2 Analog Input Modules e 0 ALA na 3 1 2 1 ADAM 5013 3 ch RTD Input Module s 21 1 22 3 Figure 1 1 ADAM 5013 Module Front View 3 Figure 1 2 RTD Inputs eeeueee esse nenn 4 Table 1 2 Technical Specifications of ADAM 5013 4 Figure 1 3 Applying Calibration Resistance 5 Table 1 3 Calibration Resistances of ADAM 5013 5 1 2 2 ADAM 5017 8 ch Analog Input Module s 422111 241 6 Figure 1 4 ADAM 5017 Module Front View nen 6 Figure 1 5 Millivolt and Volt Input 22440044s nennen 6 Figure 1 6 Process Current Input
38. SEN2 EXC2 AGND LI f OO J IM L IOOD I i IOODODDI LJ BBDBDDBSBH PPBHBDBDDBDHDHDD 16 Figure 1 1 ADAM 5013 Module Front View 3 ADAM 5000 Series User Manual Application Wiring EXC0 SENO SENO Exco A GND Figure 1 2 RTD Inputs Technical Specifications of ADAM 5013 Table 1 2 Technical Specifications of ADAM 5013 Analog input channels 3 Input type Ptor Ni RTD RTD type and temperature range Pt 100 to 100 C a 0 00385 Pt 0 to 100 C a 0 00385 Pt 0 to 200 C a 0 00385 Pt 0 to 600 C a 0 00385 Pt 100 to 100 C a 0 00392 Pt 0 to 100 C a 0 00392 Pt 0 to 200 C a 0 00392 Pt 0 to 600 C a 0 00392 Ni 80 to 100 C Ni 0 to 100 C Isolation voltage 3000 Voc Sampling rate 10 samples sec total Input impedance 2 M Bandwidth 13 1 Hz 50 Hz 15 72 Hz 60 Hz Input connections 2 3 or 4 wire Accuracy 0 1 or better Zero drift 0 015 C C Span drift 0 01 CPC CMR 50 60 Hz 150 dB NMR 50 60 Hz 100 dB Power consumption 1 2 W ADAM 5000 Series User Manual 4 ADAM 5013 RTD Input Resistance Calibration 1 2 Apply power to the module and let it warm up for about 30 minutes Make sure that the module is correctly installed and is properly con figured for the input range you want to calibrate You can use the ADA
39. ate simultaneously in the mode TE you have selected i e If you switch the ADAM 5081 to Counter Mode all four channels will operate in Counter Mode ADAM 5000 Series User Manual 62 Features Counter Mode Up Down Counting The Up Down Counter Function offers two types of counting Up Counting increas ingly and Down Counting decreasingly Up Counting when COA and COA sense any input signals the counter counts up Down Counting when COB and COB sense any in put signals the counter counts down On receiving Up and Down signal simultaneously the counter will not perform each specific counting accordingly but will remain at the previous counting value since these simultaneous signals won t have any effect on counting values k COA COA C0B D COB D Figure 6 15 Wiring for Up Down Counting Note Ifyou need only one type of counting connect COA and COA for Up N Counting only or connect COB and COB JE Counting only Bi direction Counting for Down For implementing Bi direction Counting you need to connect COB D and COB D to implement the control function for Up Down Counting Up Counting when the input sig nal is within logic level 1 the counter value increases COA COA C0B D C0B D Figure 6 16 Wiring for Bi direction Counting Down Counting when the input signal is within logic decreases 63 level 0 the counter value ADAM 5000 Serie
40. cifications 76 7 1 3 ADAM 5095 2 port CAN Serial Communication Module with isolation protection Only for B version of ADAM 5550 Series 77 Figure 7 7 ADAM 5095 Module e eseaueaaaa aaa aaaaaaaach 77 Table 7 7 CAN Serial Port Pin Assignment CAN1 CAN2 78 vii ADAM 5000 Series User Manual Table 7 8 ADAM 5095 DTE Pin Wiring 79 Table 7 9 Maximum Bit rate vs Bus Length 79 Chapter 8 Storage Modules 1 OF 8 1 Storage MOdUlES u nennen 82 8 1 1 Compatible ADAM 5000 Series Main Units 2 212121111 82 Figure 8 1 ADAM 5030 Module Frontal View 82 Table 8 1 Technical Specifications of ADAM 5030 82 Chapter 9 Motion Modules 83 9 1 Motion MOdUlES eela ee en A 84 9 1 1 ADAM 5202 4 port AMONet Master Module 84 Figure 9 1 ADAM 5202 Module Front View 84 Table 9 1 Technical Specifications of ADAM 5202 84 ADAM 5000 Series User Manual viii Chapter 1 Overview 1 1 Introduction This manual will discuss in detail the specifications functions and application wiring of the ADAM 5000 series of I O modules To organize an ADAM 5510 Series Controller you need to select I O modules to interface the main unit with field devices o
41. dule Front View Application Wiring 45 ADAM 5000 Series User Manual External Internal 5 40 Vpc Figure 4 22 ADAM 5056SO Module Wiring Diagram Table 4 9 Technical Specifications of ADAM 5056SO Points 16 8 ch group Digital Output Open collector to 40 V 200 mA max load per channel Optical Isolation 2500 VDC Opto isolator response time 125 us Supply Voltage 5 40 VDC Power consumption 0 6 W LED Indicator On when active I O Connector Type 21 pin plug terminal ADAM 5000 Series User Manual 46 4 1 10 ADAM 5057S 32 ch Isolated Digital Output Module The ADAM 5057S provides 32 isolated digital output channels for critical environ ments need individual channel isolating protection Different from other ADAM 5000 I O modules ADAM 5057S designed with 40 pin flat cable wiring terminal 32 DO ADAM 50575 Chonnel 0 1 23 45 6 7 Yee Gnat 8 9 Figure 4 23 ADAM 5057S Module Front View Application Wiring Figure 4 24 ADAM 5057S Module Wiring Diagram Table 4 10 ADAM 5057S Technical Specification Points 32 Digital Output Contact with ADAM 3920R Optical Isolation 2500 VDC Contact Rating 10 A 250VAC 10 A 30VDC Power Input 24 VDC Power consumption 1 W max Relay Type SPST Form A I O Connector Type 40 pin flat cable wiring terminal 47 ADAM 5000 Series User Manual ADAM 5000 Series User Manual 48
42. e to the mod ule s VO and VO terminals See Tables 5 2 and 5 3 for reference voltages for each range H A Voltage Source Figure 3 1 Applying Calibration Voltage ADAM 5000 Series User Manual 24 4 Enable Calibration Function in Setup menu File Tools Setup Help Favorites Group Refresh COM and LAN Node Add COM Port Tree Nodes Show TreeView Enable Calibration Function Save Load Configuration 5 Use a precision voltage source to apply a span calibration voltage to the mod ule s V0 and VO terminals 6 Click Zero and apply the voltage as pop out windows to the Ch 0 and click File Tools Setup Help OM lt s gt ajw ADAM 5017UH MODBUS r Save Load Configuration Save Load 10 0 0 99 EH 10 0 0 50 ADAM QB 501750 zj 3 5017481 5017H 82 Please apply oo mv to the Ch 0 of the module Press Apply button to do the calibration 5017 81 5017H82 501884 50184485 Please apply foo to the Ch 0 of the module Press Apply button to do the calibration 25 ADAM 5000 Series User Manual 7 Click Span and apply the voltage as pop out windows to the Ch 0 and click Apply File Tools Setup Help BAS FPP ale gt gi Serial ADAM 5018 MODBUS EX Ethemet i Eur 10 0 0 99 r Save Load
43. ed Digital Output Module with LED 44 Figure 4 21ADAM 5056SO Module Front View 45 Figure 4 22ADAM 5056SO Module Wiring Diagram 46 Table 4 9 Technical Specifications of ADAM 5056S0 46 ADAM 5057S 32 ch Isolated Digital Output Module 47 Figure 4 23ADAM 5057S Module Front View 47 Figure 4 24ADAM 5057S Module Wiring Diagram 47 Table 4 10 ADAM 5057S Technical Specification 47 Chapter 5 Relay Output Modules 49 5 1 Relay Output Modules eeueeeee eee aaa aaa aaa aaa aaa aaa aaa 50 5 1 1 ADAM 5000 Series User Manual ADAM 5060 Relay Output Module uusrs4240sn nennen 50 vi Chapter Chapter 6 6 1 7 7 1 Figure 5 1 ADAM 5060 Module Frontal View 50 Figure 5 2 Relay Output eeeeee eee aaa aaa aaa aaa aan 50 Table 5 1 Technical Specifications of ADAM 5060 50 Figure 5 3 ADAM 5068 Module Front View 51 Figure 5 4 Relay Output 51 Table 5 2 Technical Specifications of ADAM 5068 51 Figure 5 5 ADAM 5069 Module Front View Wiring 52 Counter Frequency Modules 53 Counter Frequency Modules eeuueee eee aa aaa aaa aaa aaa ennen s serne 54 6 1 1 ADAM 5080 4 ch Counter
44. elect the proper jumper settings for either TTL or Isolated Input according to Figure 63 Please note that you must configure all six jumpers to the correct con figuration for proper function ADAM 5000 Series User Manual 66 LED 6 jumpers O O O O O O O O Figure 6 22 Jumper Location on the ADAM 5081 Module 0000000000000000 OOOO DOOOODDOOO TTL Input Level Isolated Input Level Figure 6 23 TTL Isolated Input Level Select Table 6 2 ADAM 5081 Technical Specifications Channel 4 Input Frequency 5 Hz 1 MHz max Frequency mode 1 MHz max Counter mode Input Level Isolated or TTL level Minimum Pulse Width 1 u sec Frequency mode 1 u sec Counter mode Minimum Input Current 2mA Isolated Isolated Input Level Logic Level 0 3 Vw Logic Level 1 10 V to 30 V TTL Input Level Logic Level 0 0 V to 0 8 V Logic Level 1 2 3 to5 V Isolated Voltage 2500 Vans Mode Counter Up Down Bi direction up A B Phase Frequency Programmable Digital Noise 1 65000 u sec Filter 67 ADAM 5000 Series User Manual VCC I I I I I Cx I O i Cx K 10 30V x l Van O i Cx l O cx LI l Internal External nternal External Isolated input TTL input IVCC DO Optional Internal External Isolated DO output Add a di
45. er 2 Storage Type SD Secure Digital Card Storage Number 2 Operating Temperature 0 60 32 140 Certification CE Power Consumption 3 W Max Max Storage 1G Max x 2 Format FAT16 Surge Protection 10kW Hot Swap Yes ADAM 5000 Series User Manual 82 Chapter 9 Motion Modules 9 1 9 1 1 Motion Modules ADAM 5202 4 port AMONet Master Module The ADAM 5202 provides 4 port AMONet Master Module When you insert the SD card into the ADAM 5202 please remove the name plate first Please be careful to remove it If you remove it with great exertion it may be damaged ADAM 5202 Diagram Figure 9 1 ADAM 5202 Module Front View Table 9 1 Technical Specifications of ADAM 5202 Certifications CE Power Consumption 0 5 W Max Connectors RJ 45 LED Indictors Active Error Each Port Number of Rings 2 Transmission Speed 2 5 5 10 or 20 Mbps with automatic data flow control Serial Interface Half duplex RS 485 with transformer isolation Cable Type CAT5 UTP STP Ethernet cable Surge Protection 10 KV Communication Max 100 m 20 Mbps 32 slave modules 50 m 20 Mbps 64 slave modules Distance Communication Slave 2 Rings with Max 128 1 Ring with 64 slaves Module Number Operating Temperature 0 50 C 32 122 F ADAM 5000 Series User Manual
46. ety switches or to receive remote digital signals Warning A channel may be destroyed if it is subjected to an input signal while it is configured to be an output channel Dip Switch Key ON Digital Output FF Digital Input Figure 4 1 DIP Switch Setting for Digital I O Channel ADAM 5050 v1 v2 V3 V4 V5 V6 ADAM 5050 AG Sy Sif Si Sy Sy Sy Si Si Si Ss 16 UDIO O Si Si Si Figure 4 2 ADAM 5050 Module Frontal View ADAM 5000 Series User Manual 32 Application Wiring 5V 5V l rq A SEI Internal Logic TX L Figure 4 3 Dry Contact Signal Input ADAM 5050 we H 5V 5V Logic level 0 2V max Logic level 1 4V to 30V S ip 9 S Internal Logic E Figure 4 4 Wet Contact Signal Input ADAM 5050 u Ew Vss Internal Logic S S R2 limits current to 100 mA Open Collector rza amp o Vss Power Power Ground Ground Figure 4 5 Digital Output with SSR ADAM 5050 5056 33 ADAM 5000 Series User Manual Table 4 1 Technical Specifications of ADAM 5050 Points 16 Channel Setting Bitwise selectable by DIP switch Digital Input Dry Contact Logic Level 0 close to GND Logic Level 1 open Wet Contact Logic Level 0 2 V max Logic Le
47. formation about the number of slot and COM port you may refer to the section of ADAM 5091 COM port configuration in ADAM 5550KW series Manual LED Status of the ADAM 5091 Module There are two LEDs for each port on the front panel ofthe ADAM 5091 to display spe cific communication status M a Red LED RX Data Receiving Status the LED indicator is on when the port is receiving data m b GeenLED TX Data Transmitting Status the LED indicator is on when the port is transmitting data ADAM 5095 2 port CAN Serial Communication Module with isolation protection Only for B version of ADAM 5550 Series ADAM 5095 is a special purpose communication module that offers the connectivity of the Controller Area Network CAN With its built in CAN controllers the ADAM 5095 provides bus arbitration and error detection with an automatic transmission repeat function This drastically reduces the chance of data loss and ensures system reliability The on board CAN controllers are located at different positions in the mem ory and you can run both CAN controllers independently at the same time With high compatibility the ADAM 5095 can be used in diverse systems ADAM 5095 Diagram 2CAN O ADAM 5095 Port1 OO Rx Port2 KOOR Figure 7 7 ADAM 5095 Module 77 ADAM 5000 Series User Manual CAN Serial Port Pin Assignment Table 7 7 CAN Serial Port Pin Assignment CAN1 CAN2 Pin CAN Signal Definition
48. his warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Part No XXXXXXXXXX Edition
49. i cations lts high common mode provides 200 VDC protecting the module and peripherals from damage due to high input line volt age Additionally the module uses analog multiplexers with active over voltage protection The active protection circuitry assures that signal fidelity is maintained even under fault conditions that would destroy other multiplexers This module can withstand an input voltage surge of 60 VDC 7 ADAM 5000 Series User Manual ADAM 5017P DSO0000S0000000 0 Figure 1 7 ADAM 5017P Module Front View Application Wiring Figure 1 9 Process Current Input Note To keep measurement accuracy please short the channels that are not N in use ja ADAM 5000 Series User Manual 8 1 2 4 Table 1 5 Technical Specifications of ADAM 5017P Analog Input Channels Eight differential and independent Input Type mV V uni polar and bipolar mA Input Range 150 mV 500 mV 1 V 5 V 10 V 0 150mV 0 500mV 0 1V 0 5V 0 10V 0 15V and 20 mA and 4 20mA High common mode 200 VDC Sampling Rate 10 samples sec total Resolution 16 bits Over Voltage 60 VDC Input Impedance 800KQ voltage input 1200 current input Built in TVS ESD protection Yes Accuracy 0 1 or better Voltage mode 0 2 or better Current mode Zero Drift 6 uV PC Span Drift 25 PPM C CMR Q 50 60 Hz 92 dB min Power Consumption 1 25 W Max ADAM 5
50. i v6 ln a SEHR CIC jg k 6 NI Figure 1 21 ADAM 5018P Module Front View ADAM 5000 Series User Manual 16 Application Wiring T C Figure 1 22 Thermocouple Input Table 1 11 Technical Specifications of ADAM 5018P Analog Input Channels Seven differential amp independent thermocouple Input Type mV V mA Thermocouple Input Range 15 mV 50 mV 100 mV 500 mV 1 V 2 5 V and 20 mA T C Type and Temperature J 0 to 760 C Range K 0 to 1370 C T 100 to 400 C E 0 to 1400 C R 500 to 1750 C S 500 to 1750 C B 500 to 1800 C Isolation Voltage 3000 VDC Sampling Rate 10 samples sec Selected by Utility Input Impedance 2MQ voltage input 1200 current input Bandwidth 13 1 Hz 50 Hz 15 72 Hz 60 Hz Accuracy 0 1 or better Zero Drift 6 uV C Span Drift 25 PPM C CMR 50 60 Hz 92 dB min Power Consumption 0 5W 17 ADAM 5000 Series User Manual ADAM 5000 Series User Manual 18 Analog Output Modules 2 1 Analog Output Modules 2 1 1 ADAM 5024 4 ch Analog Output Module The ADAM 5024 is a 4 channel analog output module It receives its digital input through the RS 485 interface of the ADAM 5510 system module from the host computer The format of the data is engineering units It then uses the D A converter controlled by the system module to convert the digital data into output signals You can specify slew
51. iA O Jo Ole CAN L GND CAN H OOO O JO O Termination Resistor Settings Terminal resistors are factory installed to allow for impedance matching These resis tors can be enabled by utilizing SW1 and SW2 for each port shown below The value of the resistor should equal the characteristic impedance of the signal wires approximately 120 ohms The following figure shows resistor placements Enable Termination Resistor for CAN1 and CAN2 Ports SW1 and SW2 CAN Port 1 CAN Port 2 v U N D k oobk OO O 10 3 BRICK Back Board o N I O Slots and I O Ports Numbering There re two PCI slots on the version B of ADAM 5550 series If only one ADAM 5095 module is used no mater which PCI slot is plugged the port number shown in the Utility would be CANT and CANZ If two ADAM 5095 modules are used the port number shown in the Utility would be CAN1 and CAN2 for the first PCI slot and CAN3 and CAN4 for the second PCI slot CAN Serial Port Wiring The CAN standard supports half duplex communication This means that just two wires are used to transmit and receive data DTE DTE DTE CANTransceiver CANTransceiver CANTransceiver CAN H CAN L CAN can L CAN H CAN L a u rn N rs VET NA en en ee MO OU DOC AX X A ADAM 5000 Series User Manual 78 Wiring connections are as follows Table 7 8
52. ies User Manual ADAM 5000 Series User Manual 22 Analog I O Module Calibration 3 1 3 1 1 Analog I O Module Calibration Analog input output modules are calibrated when you receive them However cali bration is sometimes required No screwdriver is necessary because calibration is done in software with calibration parameters stored in the ADAM 5000 analog I O module s onboard EEPROM The ADAM 5000 system comes with the ADAM utility software that supports calibration of analog input and analog output Besides the calibration that is carried out through software the modules incorporate automatic Zero Calibra tion and automatic Span Calibration at boot up or reset ADAM 5000 Series Analog Input Module Calibration Modules ADAM 5017 5017P 5017H 5017UH 5018 and 5018P Calibration Steps 1 2 File Tools Setup Help HA 7 gt mw Apply power to the ADAM 5000 system that the analog input module is plugged into and let it warm up for about 30 minutes Ensure that the module is correctly installed and is properly configured for the input range you want to calibrate You can do this with the ADAM utility soft ware Save Load Configuration Save Load 10 0 0 99 10 0 0 50 ADAM AR 501780 50174651 501 7H S2 501854 5018 85 Use a precision voltage source to apply a span calibration voltag
53. ing protection Different from other ADAM 5000 I O mod ules ADAM 5056S designed with 21 pins plug terminal ADAM 5056S RZ 16 DO O ADAM 5056S Figure 4 19 ADAM 5056S Module Front View 43 ADAM 5000 Series User Manual Application Wiring External Internal E1 5 40 Voc Figure 4 20 ADAM 5056S Module Wiring Diagram Table 4 8 Technical Specifications of ADAM 5056S Points 16 8 channel group Digital Output Open collector to 40 V 200 mA max load per channel Optical Isolation 2500 Voc Opto isolator response time 25 us Supply Voltage 5 40 Voc Power consumption 0 6 W LED Indicator On when active I O Connector Type 21 pin plug terminal 4 1 9 ADAM 5056SO 16 ch Isolated Digital Output Module with LED The ADAM 5056S0 provides 16 channels source type isolated digital output for criti cal environments need individual channel isolating protection Addition to the source output wiring all of the specification and command sets are the same with ADAM 5056S ADAM 5056SO ADAM 5000 Series User Manual 44 16 DO NA ADAM 5051SO DIO DI1 DI2 DI3 DI4 DI5 DI6 Figure 4 21 ADAM 5056SO Mo
54. m support where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software OS version application software etc A complete description of the problem The exact wording of any error messages Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage m To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components iii ADAM 5000 Series User Manual Safety Instructions 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Read these safety instructions carefully Keep this User Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equip ment and must be easily acce
55. nter value exceeds Maxi mum value the overflow value increases when the counter value goes under Minimum value the overflow value decreases Besides when the counter value runs beyond the range of Max Min value it will continue counting from the initial value Furthermore if users want to check the counter value to see if it is higher or lower than the Max Min value they can use the ReadOverflowFlag library to gain readout of the over flow value Getting the Totalizer Value If users want to get the actual counter value a formula such as follows can facilitate an easy calculation from the initial counter value overflow value and current counter value Viol Vini Vmin or Vmax 1 x Vvr Vini Vcur Viol totalizer value Vini initial counter value V min min counter value 0 fixed value Vmax max counter value 2 2 4 294 967 295 fixed value Vvf_ overflow value Vcur current counter value Example If the initial value 10 overflow value 4 min value 0 current counter value 3 the totalizer value could be Totalizer value 10 O 1 x 4 10 3 51 65 ADAM 5000 Series User Manual Features Digital Output Mapping If users want to use Digital Output function ADAM utility is available for setting specif ically which module channel or slot to receive the alarm signals amp ADAM 4000 5000 Series Setup Utility Program 5
56. ode if load is relay ADAM 5000 Series User Manual 68 Chapter f Serial Modules 7 1 Serial Modules Compatible ADAM 5000 Series Main Units The ADAM 5090 is a 4 port RS 232 communication module to be implemented with the following Advantech ADAM 5000 series main units ADAM 5510 with library Version V1 10 or above ADAM 5511 with library Version V1 10 or above 7 1 1 ADAM 5090 4 port RS 232 Communication Module Bi direction Communication The ADAM 5090 is equipped with four RS 232 ports which makes it especially suit able for bi direction communication It can simultaneously read data from other third party devices such as Bar Code and PLC as long as these devices are equipped with a RS 232 interface Furthermore the ADAM 5090 can issue commands to control other devices It is fully integrated with the ADAM 5000 ADAM 5500 and ADAM 4000 series and transmits data to each other through the RS 232 port The whole integrated system is an intelligent stand alone system and can connect and issue commands to control devices such as printers and PLCs in remote factory location The ADAM 5090 transmits and receives data by polling communication and each port can receive up to 128 bytes in the FIFO For continuous data longer than 128 bytes please refer to Table 20 for Baud Rate setting to avoid data loss Table 7 1 Baud Rate Settings Baud Rate bps 115200 57600 38400 19200 9600 14800 12400 Polling interval ms 11 11
57. program Digital Output Mapping Users can either run the utility program or issue a Set Alarm Connection command to designate a specific digital output module for the alarm signal to be sent through ADAM 5000 Series User Manual 54 ADAM 5080 Module Diagram Figure 6 1 ADAM 5080 Module ADAM 5080 Application Wiring Veg Internal Logic Figure 6 2 Isolated Input Level Figure 6 3 TTL Input Level 55 ADAM 5000 Series User Manual ADAM 5080 Counter Frequency Mode Selection Users can select Bi direction Up Down Counter or Frequency options as shown below ADAM 4000 5000 Series Setup Utility Program File Tools Help gt alul 5 S PC r ADAM 5080 gi COMI a COM2 fill 00 5000 E 50 5024 r General Setting 1 5013 URO m Y 52 5018 nput Range _ TBi direction counter H 53 5080 i Bi direction counter Dats Eoma Up Down counter Freguency Update r Data Area CHO Joooona HI Alam Off LO Alarm Off CHI 000064 HI Alarm Off LO Alam Off CH 2 000000 HI Alam On LO Alam Off CH 3 000000 HI Alarm Off LO Alarm Off COM 2 3600 bps Polling current data 2001 9719 AM 09 45 Figure 6 4 Counter Frequency Mode Note All four channels of ADAM 5080 will operate simultaneously in the mode N you have selected i e If you switch the ADAM 5080 to Counter Mode JE all four channels will
58. r processes that you have previously determined Advantech provides 23 types of ADAM 5000 I O modules for various applications so far Following table is the I O modules support list we provided for user s choice Table 1 1 Supported I O Module List Module Name Specification Reference Analog I O ADAM 5013 3 ch RTD input Isolated ADAM 5017 8 ch Al Isolated ADAM 5017P 8 ch Al with independent Input Isolated ADAM 5017H 8 ch High speed Al Isolated ADAM 5017UH 8 ch Ultra High speed Al Isolated ADAM 5018 7 ch Thermocouple input Isolated ADAM 5018P 7 ch Thermocouple input with Isolated independent Input ADAM 5024 4 ch AO Isolated Digital I O ADAM 5050 7 ch DI O Non isolated ADAM 5051 16 ch DI Non isolated ADAM 5051D 16 ch DI w LED Non isolated ADAM 5051S 16 ch Isolated DI w LED Isolated ADAM 5052 8 ch DI Isolated ADAM 5053S 32 ch Isolated DI Isolated ADAM 5055S 16 ch Isolated DI O w LED Isolated ADAM 5056 16 ch DO Non isolated ADAM 5056D 16 ch DO w LED Non isolated ADAM 5056S 16 ch Isolated DO w LED Isolated ADAM 5056SO 16 ch Iso DO w LED source Isolated ADAM 5057S 32 ch Isolated DO Isolated Relay Output ADAM 5060 6 ch Relay output Isolated ADAM 5068 8 ch Relay output Isolated ADAM 5069 8 ch Relay output Isolated Counter ADAM 5080 4 ch Counter Frequency Isolated Frequency ADAM 5081 4 ch High Speed Counter Frequency Isolated Serial I O ADA
59. rates and start up currents through the configuration software The ana log output can also be configured as current or voltage through the software utility The mod ule protects your equipment from ground loops and power surges by providing opto isolation of the D A output and transformer based isolation up to 500 VDC Slew Rate The slew rate is defined as the slope indicated the ascending or descending rate per second of the analog output from the present to the required ADAM 5024 4 AO gt gt gt Q gt 5 2 5 VA Be 5 5 5 WO S 5 Figure 2 1 ADAM 5024 Module Frontal View Application Wiring mA Output V Output Figure 2 2 Analog Output ADAM 5000 Series User Manual 20 Technical Specifications of ADAM 5024 Table 2 1 Technical Specifications of ADAM 5024 Analog Output Channels Four Output Type V mA Output Range 0 20mA 4 20mA 0 10V Isolation Voltage 3000 Vdc Output Impedance 0 5 Ohms Accuracy 0 1 of FSR for current output 0 2 of FSR for voltage output Zero Drift Voltage output 30 uV C Current output 0 2 A C Resolution 0 015 of FSR Span Temperature Coefficient 25 PPM C Programmable Output Slope 0 125 128 0 mA sec 0 0625 64 0 V sec Current Load Resistor 0 500 Ohms source Power Consumption 2 5W Max 21 ADAM 5000 Ser
60. re designed for current input ADAM 5017UH Figure 1 14 ADAM 5017UH Module Front View Application Wiring Figure 1 16 Process Current Input ADAM 5000 Series User Manual 12 AIN JP1 JP8 Enable Voltage default JP1 JP8 Disable Current Cn i I F3dB 2wRnCn Ren AIN Internal Field Side Figure 1 17 Locations of RC Filter Jumper Setting Chuje Sae SME eine e Vue ea oe mle ele Eee JP1 JP2 JP3 JP4 JP3 JP6 1P7 of JP8 R35 R36 R37 R38 R39 R40 R41 R42 c12 c13 c19 14 cls C16 c17 C18 JP1 8 1 Nu CH R42 amp C19 Figure 1 18 Locations of RC Filter Jumper Setting Note To maintain measurement accuracy please short channels not in use A 13 ADAM 5000 Series User Manual Table 1 8 Technical Specifications of ADAM 5017UH Analog Input Channels Eight differential Resolution 12 bits Input Type mV V mA Input Range 0 10V 10 V 4 20mA and 20 mA Isolation Voltage 3000 VDC Sampling Rate 200k samples sec single channel 50k samples sec 8 channel Analog Input Signal Limit 15 V max Max allowable voltage dif ference between two con nectors in a module 15 V max Input Impedance 2MQ voltage input 1202 current input Bandwidth 200kHz Accuracy 0 1 or better Low or high pass filter Configured by User CMR Q 50 60 Hz 92 dB min Power Requiremen
61. ring S I Ca ki S W mv v i Sy Figure 1 6 Process Current Input ADAM 5000 Series User Manual 6 1 2 3 Note To keep measurement accuracy please short the channels that are not in use Technical Specifications of ADAM 5017 Table 1 4 Technical Specifications of ADAM 5017 Analog Input Channels Eight differential Input Type mV V mA Input Range 150 mV 500 mV 1 V 5 V 10 V and 20 mA Isolation Voltage 3000 VDC Sampling Rate 10 samples sec total Analog Input Signal Limit 15 V max Max allowable voltage difference 15 V max between two connectors in a module Input Impedance 2MQ voltage input 1202 current input Bandwidth 13 1 Hz Q 50 Hz 15 72 Hz Q 60 Hz Accuracy 0 1 or better Zero Drift 1 5 V C Span Drift 25 PPM C CMR Q 50 60 Hz 92 dB min Power Requirements 10 to 30 VDC non regulated Power Consumption 1 2 W ADAM 5017P 8 ch Al with independent Input The ADAM 5017P is a 16 bit 8 channel analog differential input and independent configuration module It accepts mill volt inputs 150mV 500mv 0 150mV 0 500mV 0 1V 0 5V 0 10V 0 15V voltage inputs 1V 5V 10V and 20V and current input 20 mA 4 20mA The module provides data to the host computer in engineering units mV V supports uni poloar and bipolar or mA This module is an extremely cost effective solution for industrial measurement and monitoring appl
62. s User Manual Note Ifusers select TTL mode and don t connect COB COB the counter Ta value will increase If users select Isolated mode and don t connect COB COB the counter value will decrease Features Frequency Mode If users want to select frequency mode they can only utilize Up Counting type and can only connect to COA and COA COA CoA C0B D CoB D Figure 6 17 Wiring for Frequency Mode Features Alarm Setting According to your application purposes you can run the utility program to set different limit values for High Low Alarm 50 5024 51 5013 fan pomo ig a pomoca Figure 6 18 Setting Alarm Limit ADAM 5000 Series User Manual 64 Setting Initial Counter Value In order to utilize the alarm function users have to set ahigh alarm limit value and or a low alarm limit value and an initial value to fulfill the requirements for a basic alarm setting Max value Sending High alarm High alarm limit value Initial value Sending Low alarm NZ Low alarm limit value w Min value Figure 6 19 Sending Alarm Signal Recommended Settings Max value Initial value Sending High alarm High alram Initial value Sending low alarm Low alarm limit value Min value Figure 6 20 Sending Alarm Signal Not Recommended Overflow Value Overflow value is the number of times the counter value exceeds the Max Min val ues you specified When the cou
63. ssible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted Ifthe equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the user s manual The equipment has been dropped and damaged The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE INA CONT
64. t if data received read a character if port_rx_ready 1 character port_rx 1 check whether FIFO is empty or not if empty send a character if port_tx_empty 1 port_tx 1 character ADAM 5000 Series User Manual 74 7 1 2 ADAM 5091 4 port RS 232 Communication Module with share interrupt Only for ADAM 5550 Series Bi direction Communication The ADAM 5091 is equipped with four RS 232 ports with share interrupt which makes it especially suitable for bi direction communication It can simultaneously read data from other third party devices such as Bar Code and PLC as long as these devices are equipped with a RS 232 interface Furthermore the ADAM 5091 can issue commands to control other devices It is fully integrated with the ADAM 5550 and trans mits data to each other through the RS 232 port The whole integrated system is an intelligent stand alone system and can connect and issue commands to control devices such as printers and PLCs in remote factory location The ADAM 5091 transmits and receives data by sharing interrupt communication and each port can receive up to 128 bytes in the FIFO For continuous data longer than 128 bytes please refer to Table 27 for Baud Rate setting to avoid data loss Table 7 4 Baud Rate Settings Baud Rate bps 115200 57600 38400 19200 9600 14800 12400 Polling interval ms 11 11 22 22 33 33 66 66 133 33 266 66 533 33 Communication
65. t Module 15 Figure 1 19ADAM 5018 Module Front View 11112112 15 Figure 1 20 Thermocouple Input nenneneeeeeenenn 15 Table 1 10 Technical Specifications of ADAM 5018 16 1 2 7 ADAM 5018P 7 ch Thermocouple Input Module 16 Figure 1 21ADAM 5018P Module Front View 16 Figure 1 22Thermocouple Input se sees eee eee ea aeaaaaaaaaaa 17 Table 1 11 Technical Specifications of ADAM 5018P 17 Analog Output Modules 19 Analog Output Modules 2 4220 se ssseaseasa aneii 20 2 1 1 ADAM 5024 4 ch Analog Output Module 111121121 20 Figure 2 1 ADAM 5024 Module Frontal View 20 Figure 2 2 Analog Output e eeeeee eee ea aaa aaa aaa aaaaaac ca 20 Table 2 1 Technical Specifications of ADAM 5024 21 Analog I O Module Calibration 23 Analog I O Module Calibration 4444ss4 nennen nennen 24 3 1 1 ADAM 5000 Series Analog Input Module Calibration 24 Figure 3 1 Applying Calibration Voltage u 24 V ADAM 5000 Series User Manual Table 3 1 Calibration Voltage of ADAM 5017 5018 27 Table 3 2 Calibration Voltage ADAM 5017H 27 Table 3 3 Calibration Voltage of ADAM 5018P
66. ts 10 to 30 VDC non regulated Power Consumption 1 75 W typical 2 2W max Signal Input Bandwidth 200kHz for both voltage and current inputs Table 1 9 ADAM 5017UH Input Sgnal Ranges Input Range Offset Offset Error Gain Error Gain Error Display Error 10 to 70 C 25 C 10 to 70 C Resolution 25 C Voltage 0 10 V 1 LSB 2LSB 1 LSB 2 LSB 2 7 mV Inputs 40 V 1 LSB 2 LSB 1 LSB 2 LSB 2 7 mV Current 0 20 mA 1LSB 1LSB 1 5LSB 2 LSB 5 3 u Inputs 4 20mA 1LSB 1LSB 1 5LSB 2 LSB 5 3 u ADAM 5000 Series User Manual 14 1 2 6 ADAM 5018 7 ch Thermocouple Input Module The ADAM 5018 is a 16 bit 7 channel thermocouple input module that features pro grammable input ranges on all channels It accepts millivolt inputs 15 mV 50 mV 100 mV 500 mV voltage inputs 1 V 2 5 V current input 20 mA requires 125 ohms resistor and thermocouple input J K T R S E B The module forwards the data to the host computer in engineering units mV V mA or temperature C An external CJC on the plug in terminal is designed for accurate tem perature measurement ADAM 5018 Sn 7 T C O ADAM 5018 vo Sl vo sj VI Sy VI Sy V2 V2 Sy V3 si V3 Sy V4 S V4 ee V5 R V5 Sy V V6 s CJC S oaz HABEN CJC h 16 Figure 1
67. vel 1 4 V to 30 V Digital Output Open collector to 30 V 100mA max load Power Dissipation 450 mW Power Consumption 0 4 W 4 1 2 ADAM 5051 D 16 ch Digital Input Module The ADAM 5051 provides sixteen digital input channels The ADAM 5510 can use the module s digital inputs to determine the state of limit or safety switches or to receive remote digital signals ADAM 5051 5051D 16 DI ADAM 5051 Figure 4 6 ADAM 5051 Module Frontal View ADAM 5000 Series User Manual 34 Application Wiring 5VDC 30VDC gt 10K Digital TTL Input Input Internal Logic Power GND Figure 4 7 TTL Input ADAM 5051 5051D 5VDC 30VDC gt 10K Contact Digital Closure Input Internal Logic Power GND Figure 4 8 Contact Closure Input ADAM 5051 5051D 35 ADAM 5000 Series User Manual Table 4 2 Technical Specifications of ADAM 5051 5051D Points 16 Digital Input Logic level 0 1 V max Logic level 1 3 5 to 30 V Pull up current 0 5 mA 10 k resistor to 5 V Power Consumption 0 3 W Indicator ADAM 5051D only 4 1 3 ADAM 5051S 16 ch Isolated Digital Input Module with LED The ADAM 5051S provides 16 isolated digital input channels for critical environments need individual channel isolating protection Different from other ADAM 5000 I O mod ules ADAM 5051S designed with 21 pins plug terminal ADAM 5051S

Download Pdf Manuals

image

Related Search

Related Contents

DZR-45 - Teddington  Nyagua Version 4.0 User Manual  IWT-5000 User`s manual  取扱説明書 - ご家庭のお客さま/大阪ガス  Operating Instructions Spare Parts List SPECK “Pumpmeister  Limited Warranty Guide    Vapo Rapid 09-2014  Texte intégral PDF (565 ko)  

Copyright © All rights reserved.
Failed to retrieve file