Home

Divar MR Operating Manual

image

Contents

1. GEREN Fh Pi WS i Rey fle YE bale hole Fs Fa Divar MR Digital Video Recorder Type numbers DVR 8K DVR 16K DVR 8L DVR 16L en Operation Manual_en Digital Video Recorder Table of contents 1i 1 19 2 1 De 2 3 2 4 Zio Sl 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 SA 312 23 3 14 3 15 3 16 cm lg 216 319 3 20 oud 3 22 3 23 3 24 4 4 1 5 3 1 52 Re Safety Important safety instructions Safety precautions Important Notices Introduction Features Accessories Front panel Back panel Remote Control Connections and settings Basic connection overview Camera connections Monitor connections Connecting the RS 232C COM 1 Port CCTV keyboard connections Network connection Connecting the USB device Connecting a RS 422 485 device Connecting the BIPHASE port Connecting the ALARM I O port System operation Selecting the main monitor type General explanation of the live screen on the main monitor Selecting live screen mode PTZ camera control Viewing System Information Viewing the System Log List Configuration Menu Camera settings Schedule settings Display settings Event settings Network settings System settings Recording Instant Recording Search and playback Playback Search Functions available during playback Bosch Security Systems User Manual Table of contents en 1 KR KRW W g 10 11 i3 14 17 17 18 18 18 19 19 19 20 21 22 23 24
2. FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 21 3 9 Connecting the BIPHASE port The Biphase port is used for connecting cameras that use Bosch Biphase communications to control camera positioning Five Biphase outputs are provided for dome camera and pan tilt and zoom control The screw terminal connection board supplied with the unit simplifies all Biphase connections to the unit Maximum cable length per Biphase output is 1 5 kilometers 0 9 miles Maximum number of controllable cameras is 4 per Biphase output SHIELD ICTRL 1 SHIELD CTRL 2 gt SHIELD ICTRL 3 gt SHIELD ICTRL 4 gt SHIELD ICTRL 5 gt SHIELD O 0 OO 0 0 00 O00 SDKSSDOVGSOSNVseSeD9S Figure 3 3 Biphase port connector BIPHASE port 15 pole D type socket Biphase control ch 3 minus 7 System ground cable shield Shield codes 1 1 1 Biphase control ch 4 plus System ground cable shield O 1 2 5 Shield a Table 3 2 Biphase pin configuration 1 i oa ce 4 4 al sod Biphase control ch 5 plus System ground cable shield Bosch Security Systems User Manual FO1U 1 0 2007 12 22 en Connections and settings Digital Video Recorder 3 10 3 10 1 3 10 2 Connecting the ALARM I O port Alarm inputs and outputs are supplied via a 25 pole D type socket The screw terminal inpu
3. The Divar MR Alarm Notifier and Divar MR Archive player programs will be installed with the Control Center installation 6 3 Connecting to the DVR 6 3 1 Register the Site Name You should register a site name to control DVR by the Control Center 1 Double Click the Divar MR Control Center icon to start the Control Center The menu is displayed 2 Select Tools gt Connection Information Bosch Security Systems User Manual FO1U 1 0 2007 12 82 en Control Center Digital Video Recorder The connection list menu is displayed Connection List Figure 6 1 Connection list window 3 Select Add and the connection setup menu is displayed Connection Setup Figure 6 2 Connection setup window 4 Enter the site name IP address and port Site Name Enter the description of the site IP Address Enter the IP Address or URL of the DVR Port Enter the Port number of the DVR If it isn t entered the port number is set by default 5 Select OK Connection List 192 168 0 16 Figure 6 3 Connection list window 6 Select OK to confirm the settings The registered site name is displayed FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 83 Note In the case of entering the server name instead of the IP Address set up the DDNS configuration properly in the server 6 3 2 User log on i Select the registered site name and right click t
4. 6 6 Search mode You can search the data of a selected site name in the remote setup tab via the network 6 6 1 Using the Date Time Search function Use to search a recorded picture by specifying date hour and minute E Pv ic J aS m o a o A S o oa ee eee i S Lire al Pre ere kere nai A on et an S Figure 6 14 The Date Time search window 1 Select the date time search tab 2 Click the date icon and select the day the selectable days are displayed in blue color 3 Select the channel window you want to view Bosch Security Systems User Manual FO1U 1 0 2007 12 92 en Control Center Digital Video Recorder Check this box when you want to view from all camera channel es CO Displays selected camera number Figure 6 15 Camera channel select window 4 Use the timeline and time input column to search recorded data 00 00 o1 02 03 04 05 06 OF 08 09 19 11 12 13 14 15 16 17 18 19 20 21 22 23 Figure 6 16 Recorded data search window 9 Playback the searched data using the playback control buttons n SS SSS SSS ee ar 4 m i Figure 6 17 The playback control buttons 6 6 2 Using the Event search function Search a recorded picture by date and event type Yi irern mme dP a Figure 6 18 The Event search window ae Select the event search tab 2 Click the date icon and select the day The selectable days are displayed in blue color Select the camera
5. Pre alarm recording up to 1 minute Motion event recording and preview test function of motion sensitivity Recording image rate amp quality adjustment per individual camera Powerful record scheduling Instant playback in live mode Perfect audio video synchronization Automatic backup by schedule Image authentication Watermark Three USB 2 0 ports for backup interface Setup configuration export import with USB memory stick or network Easy system software update with USB memory stick or network Control Center PC software can manage max 100 DVR Max five clients can access one DVR server simultaneously Network bandwidth throttle Automatically adjust a bandwidth according to network speed status of unit Remote alarm notification via PC software or e mail Time and date sync from NTP server Daylight saving mode Bosch Security Systems User Manual FO1U 1 0 2007 12 10 en Introduction Digital Video Recorder Covert camera protection e User management User level control PTZ Control For more details see 8 2 4 Supported PTZ camera list Dome camera telemetry control Dome OSD control Note Model DVR 16L 16 Channel is used for the description operation and details provided in this operation manual 2 2 Accessories DA Remote Control AAA Type Batteries for Remote Rack Mount Bracket Control Mouse Divar MR PC software Screws for rack mount bracket Power plugs
6. Pre event Specify the pre event recording time that records the situation until the input has been detected Off 5 10 20 30 40 50 sec or 1 min Post event Specify the post event recording time that records the situation after the input has been detected 10 20 30 40 50 sec or 1 2 3 5 10 min Note Pre event times given are only a rough guide Actual times are dependent upon resolution quality and frame rate settings as well as the number of channels selected for pre event recording FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 41 3 19 7 Motion recording Settings concerning motion recording me wy Camera Move Vide adj Select PTZ E3 Exit Cantinuows Ree m Camera Motion Age instant Rec m E mi Input Ree Move Ch Aesolution Quality Frame rain P e 3 Poseront gr Viden format Sos Pons ors fo a a msi fromai airs On f ioe M oiii Grom Nome i DPS fod f lOs ec CT BEIA BE r Figure 3 21 Motion recording setup menu Ch Displays the channel number Resolution Selects the recording resolution Quality Selects the recording picture quality Lowest Low Normal High or Best Frame rate Selects the frame rate The frame rate is the number of recorded frames per second According to resolution the frame rate is set automatically If you wish to set O refer to the below table 352 Resolu
7. The Alarm Notifier icon is displayed in the system tray on the bottom right of the screen Figure 7 1 The Alarm Notifier icon in the system tray 2 Whenever a notification function occurs a message box is displayed on the bottom right of the screen The message box is displayed for 5 seconds Subject Event report 11 06 2007 14 25 37 8666 Motion detected From 192 168 0 16 went message received From Your DVR system Event time 11 06 2007 14 25 37 Event type Motion detected Camera channel 13 Figure 7 2 The message box window Check the message Click the message box within 5 seconds to display the Divar MR Alarm Notifier Received Messages window or Right click the mouse on the program icon in the system tray and select the Check Message Box option to display the Divar MR Alarm Notifier Received Messages window 5 You can check all the subjects of received messages 6 Click the gaj button to close the Divar MR Alarm Notifier Received Messages window Bosch Security Systems User Manual FO1U 1 0 2007 12 106 1 2 en Additional programs Main Screen of Alarm Notifier program Diva H Alar Molier 4Beceied iessayes CSS OSSSSSSOSSOCCCOS PSOOSSSSSSOSOSSOSSSSSOHSOOCOCCOS Kt E I Everk rpt 11 08 2007 14 25 43 141 Motion detactad C Everk reput 11 06 2007 14 25 43 5113 Hotin detected D Everk report 11406
8. e Video loss On Sends an e mail when a video signal from the camera has stopped because of a cable disconnection or malfunction of a camera Off Not used Power on off On Sends an e mail when power is on or off Off Not used FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 57 3 23 4 Mail TEP SIP DONS Motiication Emergency Figure 3 43 Mail setup menu Notification On Notifies the user by e mail of unit operating information according to notification settings Off The notification function is not used The mail options are dimmed SMTP server Enter the SMTP Server address using the virtual keyboard If notification is set to On and the SMTP server option is empty the SMTP port no user name and password options are dimmed and the options are not set SMTP port no Enter the SMTP port number using the virtual keyboard Typically the port used for SMTP is 25 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1 65535 User name Enter the user name using the virtual keyboard Password Enter the password using the virtual keyboard TLS Set to On when using the TLS Transport Layer Security function By default TLS is Off e Mail address 1 3 Enter the mail address using the virtual keyboard You can input up to 3 e mai
9. pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced radio TV technician for help Intentional or unintentional modifications not expressly approved by the party responsible for com pliance shall not be made Any such modifications could void the user s authority to operate the equipment If necessary the user should consult the dealer or an experienced radio television tech nician for corrective action The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Proble
10. 29 27 28 3l 32 33 35 43 49 51 54 59 71 71 73 13 13 19 FO1U 1 0 2007 12 2 5 4 6 1 6 2 6 3 6 4 6 5 6 6 6 7 7 1 ee Lo 7 4 8 1 8 2 8 3 8 4 8 5 8 6 8 7 FO1U 1 0 2007 12 en Table of contents EXPORT Control Center PC minimum Requirements Control Center installation Connecting to the DVR Main screen of DVR Control Center Program Live Mode Search mode Remote Setup mode Additional programs Alarm Notifier program Main Screen of Alarm Notifier program Archive Player program Web Viewer program REFERENCE Troubleshooting Recommended devices Time zones Factory default configuration settings Recording Time Table 500GB HDD Recording Time Table 160GB HDD Specifications User Manual Digital Video Recorder 19 81 81 81 81 84 86 91 Ja 105 105 106 108 111 115 115 118 120 124 124 126 129 Bosch Security Systems Digital Video Recorder Safety en 3 1 Safety 1 1 Important safety instructions Read follow and retain for future reference all of the following safety instructions Heed all warnings on the unit and in the operating instructions before operating the unit a Cleaning Unplug the unit from the outlet before cleaning Follow any instructions provided with the unit Generally using a dry cloth for cleaning is sufficient but a moist fluff free cloth or leather shammy may also be used Do not use liquid cleaners or aerosol
11. DVD RW and DVD RW discs have to be initialized before using You can format the external media with the backup tab in the setup menu User Manual Bosch Security Systems Digital Video Recorder Control Center en 81 6 Control Center Control Center is the network program of the DVR 8K DVR 8L and DVR 16K DVR 16L This manual is written based on DVR 16L 16 channels The description pictures may differ from your OS Operating System type The pictures used in this manual are based on Windows XP Note Do not use other applications with this Control Center program This can cause memory shortage and Client program malfunction 6 1 PC minimum Requirements E OS Operating System Windows 2000 or above DirectX 8 1 or above CPU Intel Pentium IIl or above AMD Athlon with 800 MHz or above RAM 512 MB or above Graphics Card AGP VGA with 64 MB Video RAM or above Recommended PC Requirements e OS Windows XP e CPU Intel Pentium IV e RAM 512 MB e Graphics Card AGP VGA with 128 MB Video RAM 6 2 Control Center installation il Insert the Divar MR PC software CD which will be started automatically If the disc does not run automatically on your PC open the Divar MR PC software CD and install the program manually 2 Run the install file and install the programs to your computer following the InstallShield Wizard displayed 3 After installation finishes you will find the programs in the start menu of the computer Note
12. DVR 8K DVR 16K DVR 8L DVR 16L DVR 8L DVR 16L 30 25 77 62 39 31 74 59 37 30 20 20 89 71 44 36 85 68 42 34 High 58 46 79 63 32 74 108 87 352x288 30 25 48 39 24 19 47 38 24 19 20 20 58 46 29 23 56 45 28 22 Best 15 18 75 75 704x288 3 3 T 15 15 115 92 57 46 108 86 54 43 1 5 7 5 154 123 77 62 142 114 fajsor High 173 138 86 69 158 126 79 63 190 152 95 76 172 137 86 69 295 236 148 118 254 203 127 101 15 15 67 53 33 27 64 51 32 26 L102 101 80 50 40 95 76 48 38 Best ay he 3 3 1 1 126 101 63 51 118 95 59 47 138 111 69 55 129 103 64 51 238 191 119 95 210 168 105 84 Bosch Security Systems User Manual FO1U 1 0 2007 12 128 en Reference Digital Video Recorder Recording Time Hr Resolution IPS Video Video Audio Quality NTSC PAL NTSC PAL NTSC PAL NTSC PAL DVR 8K DVR 16K DVR 8K DVR 16K DVR 8L DVR 16L DVR 8L DVR 16L 7 5 7 5 137 110 68 55 127 102 64 51 55 177 141 88 71 161 129 80 64 Lowest 3 3 205 164 103 82 184 148 92 74 4 14 363 290 181 145 302 242 151 121 7 5 7 5 125 100 62 50 117 93 58 47 i 5 5 148 118 74 59 137 109 68 55 OW 3 3 162 130 81 65 149 119 74 60 aft 252 201 126 101 221 177 110 88 7 5 7 5 90 72 45 36 85 68 43 34 704x480 55 97 77 48 39 92 73 46 37 Normal 704x576 3 3 107 86 54 43 101 81 51 40 5 9 3 3 1 1 5 5 3 3 1 1 5 5 3 3 1 1 73 59 34 27 14 35 3 3 70 56 35 2
13. View all the channels in sequence You cannot use sequence mode with the 16 multiscreen view Information Display Window Displays current date and time user information and the remaining HDD status of the selected site name 2007 11 06 13 15 54 User Administrator Normal 99 Overwriting Event 35 S Overwriting Figure 6 6 Information Display Window Bosch Security Systems User Manual FO1U 1 0 2007 12 86 en Control Center Digital Video Recorder 6 5 Live Mode 6 5 1 Using the Camera View E Select the Camera View tab in the live mode PR Select the registered site name and double click the left mouse button or click the plus mark of the registered site name 3 Select Cameras and double click the left mouse button or click the plus mark FY Divar MR Control Center Gel Cameras GH Input In Figure 6 7 Divar MR Control Center Window 4 Select the channel number you want to view 5 Click the channel number and drag and drop to live window position If you select Cameras and drag and drop to a live window then all channels are displayed 6 Live image is displayed in the selected window moti nT oof a eee ce eae a l Figure 6 8 Camera View window e Repeat steps 3 5 to set the other live windows Note Configuration of camera view is set the first time only This configuration setup is memorized for the next time and displayed as it is FO1U 1 0 2007 12 User Manua
14. A BNC Type Connector Connect to main monitor or display device VGA Connect a VGA monitor USB Ports Connect optional extension USB devices e g mouse memory stick Remote Control O O A gt A 3 g E O p O Jo m 7 O z m Z Cc Y Q O U gt n m gt D O lt x g gt J A v gt cS o m on O v D m O lt 5 A 7 R Y NV 3 Q O Q OC QO 8 TZ TOUR f4ese Q a SET CLEAR MOVE PRESET BOSCH Figure 2 4 Remote control FO1U 1 0 2007 12 LOCK Displays the lock menu to change user type or disable system operation ACK Cancels alarm activation and returns the system to the condition before the alarm was activated Display the monitor A control menu to set the screen mode to full 4 6 8 9 or 16 screens Display the monitor B control menu to allow spot monitor control N Press to see different multiscreen modes View all channels in sequence ESC Use to return to previous level or to exit menu system without saving MENU Displays the setup menu Arrow Buttons lt gt A V Selects or moves between the menu options User Manual Bosch Security Systems Digital Video Recorder Introduction en 15 ENTER Confirms menu selections or go to full screen of a selected camera in multiscreen Pressing
15. AP ERDI ol 2 L6BU0 16 wo 92 1UE 0 16 j3 LEGO be e172 LAO 1G ejat IERD 16 9192 168 0 06 oo He LGU BG 2007 11 06 13 2259 e2071 1 04 Lew eiT ol AaS o2007 1 108 13 22 58 oR LLM ESE en L 13 225 e2007 1106 13 2203 emt Lite Mee Sant lad 13 2 Ps02 ex007 L1406 12200 So Lia ee eet LAA 15 545 eo LL 15 5038 elUt L1alg Poca eiT LL 555 eJ007 11 07 5 5728 e2007 1102 TEA e2007 Li 15 57 2007 1102 15 57 20 eZ00T L LE 19 5720 2007 11 02 15 56 53 enteb lg n eo DOC 1 Lof 15 56 e2007 L 02 15 56 35 err Lie Pore Fs a COSC CC COCO oo Tdo oo doo Tooo o oo 5 FOOHCCHEMEOOHEHCHEHHOHHOHOHHHHHEMOHHOHHOHHHHHHLEOEEO S ITYEEKYFEYEFYYIEYNFYYEEYYYYYYEYYEECEEYTIYYYEYYYYYKY Digital Video Recorder ER eS RR AS RR en RS RRR EE RSE SSS SESESERSESE SS EESSESESSEESSSESEERESSEES gt WC CCC CCC COO COCO CO OOOO OCC OOOO OC POSS OOS HSSHSSSSHSHSSSSHSOSSHSSSSSSSSHSOSSOSOSOOSSSOSSSOSOSSOOeS PIFI Je 4 ag Figure 7 3 Main Screen of Emergency Agent Displays message type Displays IP Address Displays received date and time Displays the port settings window Displays the search window Refreshes the received message on the list Detailed view of the received message Deletes the selected message from the list OONOOEeaYSE Closes the Divar MR Alarm Notifier Received Messages window FO1U 1 0 2007 12 User Manual Bosch
16. Moves the yellow cell box to another cell zone ENTER Selects or cancels the motion detection area at the current cell position Press ESC to exit the settings You can select the motion detection area by using the mouse To select the area Drag amp drop a cell to the right to select the motion detection area To cancel area Drag amp drop a cell point of a selected cell area to the left to cancel the motion detection area Note In situations where illumination is low and the outline of object is not clear enough to see regardless of sensitivity Motion Event might not activate You must check Motion Event before setting FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 53 3 22 3 Alarm acknowledgement i input Migoiiun Figure 3 39 Alarm acknowledgement setup menu Alarm ackn Manual Use the ACK button on the remote control or wt button on the front panel to stop alarm Post event time The alarm is stopped after the programmed post event time Bosch Security Systems User Manual FO1U 1 0 2007 12 54 en Connections and settings Digital Video Recorder 3 23 Network settings 3 23 1 TCP IP DONS Motimeatian Mail Emergency Remote client port m HTTP port mo Bandwidth limit Figure 3 40 TCP IP setup menu DHCP DHCP stands for Dynamic Host Configuration Protocol On Network settings of this unit are
17. RW DVD RW HDD RS 485 RS 422 Serial I F RS 232C D SUB9 1 connector 5 outputs Ethernet 10 100BaseT RJ 45 Network iia er ial Up to120 IPS 352x240 Bandwidth Control Yes Password Protection Yes Security Image Authentication Yes Display Bosch Security Systems User Manual FO1U 1 0 2007 12 130 en Reference Digital Video Recorder Max 80 W with 1x HDD Max 120 W with 4x HDD Dimension WxDxH Net Weight with 4x HDD 0 C 40 C 32 OF 104 F 0 RH 80 RH 128 ohm max Bi phase 40V 1 5 Km 0 9 miles FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 131 Bosch Security Systems User Manual FO1U 1 0 2007 12 132 en Reference Digital Video Recorder FO1U 1 0 2007 12 User Manual Bosch Security Systems Bosch Security Systems www boschsecurity com Bosch Security Systems 2007 PO WU 0 2100s P N MFL40426644
18. Security Systems Digital Video Recorder Additional programs en 107 7 2 1 Port setting Alarm Notifier pork Mo 9002 1025 65535 cancel_ Figure 7 4 Port setting window ile Click the F button The option window is displayed 2 Enter the port number of the emergency agent listening port The factory default port is 9002 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1025 65535 3 Click the OK button to exit 7 2 3 Message search Message search W Event search W Date search EVENT DATE Motion Oo detection L Video loss dmin Pw O Changed Disk Full O Power on off uj 62007 l Hard disk m damaged C alarm on mt cancel Figure 7 5 Message search window 1 Click the EJ button The message search window is displayed 2 Select the search method e Event search Search by selected type of event for the message e Date search Search by selected date 3 Click the Search button The search message is displayed on the Divar MR Alarm Notifier Received Messages window Bosch Security Systems User Manual FO1U 1 0 2007 12 108 en Additional programs Digital Video Recorder 7 2 4 Delete the message from the list L Select the message s you want to delete 2 Click the ka button The confirmation window is displayed I re vou sure
19. You can register a bookmark only in the single channel playback e You can not register a bookmark during instant playback 5 3 Functions available during playback System Remote Front panel Control Bar Control p STOP 2 Pause playback 5 Press repeatedly to select the required a scan speed PP PPP PP PP PP PPP or dd ddd ddd dd e A Press repeatedly to play frame by frame in pause mode Press to play reverse or normal playback wns Press MARK at a desired point to be ar ME er marked during playback Up to 15 points can be marked Notes e You can play back the backup or export data in normal speed only e If you use the reverse frame skip function a frame may be skipped e Multi channel play works only in the date time search function 5 4 EXPORT This unit can manually copy recorded images and audio from built in HDD to the external recording devices Bosch Security Systems User Manual FO1U 1 0 2007 12 80 en Search and playback Channel Start Date Time End Date Time Digital Video Recorder LDVD GSA H55N a ee ee ee oe 9 10 11 12 13 14 15 1 2007 7 117 06 15 2007 f 11 08 Figure 5 11 Export menu window Press COPY or click EE The export menu window appears FO1U 1 0 2007 12 Select a target device to export Select the channel number s Set the start date time and end date time to copy Press COPY or Click icon to start exporting The exported
20. booting will commence The BOSCH logo image will be displayed on the main monitor during the system booting 2 When booting is complete the login window will be displayed Select a user ID by using the mouse or arrow then the ENTER button on the remote control or front panel Please select a user name and enter a password _ ADMINISTRATOR a SS ee ollie Sloe oar tyre l l Bie DE FGA TT KIL MNO Figure 3 5 Login window ADMINISTRATOR Unlimited operation of the unit Advanced User Use of the limited functions of the system the setup configuration is not allowed to change Normal User Use of the limited functions of the system multiscreen monitor and live image view are available 3 Enter the password by using the virtual keyboard Initial password is 000000 4 Press LOCK or click the OK LOCK icon You can see the live screen and operate the system Bosch Security Systems User Manual FO1U 1 0 2007 12 24 en Connections and settings Digital Video Recorder It is not possible to connect the VGA monitor and the composite monitor simultaneously Consequently the user is obliged to choose either the composite monitor or the VGA monitor When set to composite monitor there is no VGA output When set to VGA monitor there is no composite output Monitor B is unaffected by the monitor setting This DVR is based on a VGA monitor using OSD We recommend using the VGA monitor with this unit If you use a
21. channel number Resolution Selects the recording resolution Quality Selects the recording picture quality Lowest Low Normal High or Best Frame rate Selects the frame rate The frame rate is the number of recorded frames per second According to resolution the frame rate is set automatically If you wish to set manually refer to the below table 352 240 1 3 5 1 0 15 20 30 NTSC Table 3 8 Frame rate table Bosch Security Systems User Manual FO1U 1 0 2007 12 3 19 6 Input recording Settings concerning input recording Camera Camera ase Mowe Video adj Enter FACS PT EJ Exit Cartinuous Aeg Camera Input Aar Vee ie lta oS Ts ip a l lretant Aas Mation Rae Ch Mesut Guairy Frume raie Prevent Post evert Move Eder Bile Video format ESO CET EA CT E E Prev E Sri homai f MIPS fof L Wace ES OET BEE B a EERUN ENN E Figure 3 20 Input recording setup menu Ch Displays the channel number Resolution Selects the recording resolution Quality Selects the recording picture quality Lowest Low Normal High or Best Frame rate Selects the frame rate The frame rate is the number of recorded frames per second According to resolution the frame rate is set automatically If you wish to set O refer to the below table 352 Resolution _ 1 3 5 1 0 15 20 30 NTSC o orm issen Table 3 9 Frame rate table
22. cleaners 2 Heat Sources Do not install the unit near any heat sources such as radiators heaters stoves or other equipment including amplifiers that produce heat 3 Ventilation Any openings in the unit enclosure are provided for ventilation to prevent over heating and ensure reliable operation Do not block or cover these openings Do not place the unit in an enclosure unless proper ventilation is provided or the manufacturer s instructions have been adhered to 4 Water Do not use this unit near water for example near a bathtub washbowl sink laun dry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as a wet location To reduce the risk of fire or electrical shock do not expose this unit to rain or moisture 5 Object and liquid entry Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or elec trical shock Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 6 Lightning For added protection during a lightning storm or when leaving this unit unattend ed and unused for long periods unplug the unit from the wall outlet and disconnect the cable system This will prevent damage to the unit from lightning and power line surges Fa Controls adjustment Adjust only those controls specified in
23. core Daylight saving Figure 3 45 Date Time setup menu e Date Enter the current date Time Enter the current time 24 HR or 12 HR e Date format Select the date display format Time format Select the time display format Time zone Select your Time zone for more details see 8 3 Time zones Daylight saving Set to On to use the daylight saving function Daylight saving start Select the Daylight saving start time Daylight saving end Select the Daylight saving end time Bosch Security Systems User Manual FO1U 1 0 2007 12 60 en Connections and settings Digital Video Recorder 3 24 2 NTP Undate Configuration Hard disk Backup vatem Figure 3 46 NTP setup menu NTP Set to On when using the NTP Network Time Protocol server for time adjustment If the NTP is set to Off the time settings should be entered manually and the Time server Private time server Sync interval and NTP test options are deactivated Time server For most cases select public The DVR will obtain the average time among 5 public servers time nist gov time a nist gov time b nist gov ntp nasa gov clock isc org Private time server Enter the private time server s IP address or host name using the virtual keyboard Sync interval You can set synchronized intervals with the NTP time server to 1 day 1 hour 1 month and 1 week NTP test Select NTP test to test the NTP server FO
24. data will be authorized by the unit before saving and it can only be played back with the Archive player Notes You can also use the COPY button on the front panel for export func tion DVR 16K DVR 16L Press ALT and then COPY button DVR 8K DVR 8L Press COPY button only You can export the recorded data only in the live mode If you use the external USB memory device the external USB memory device has to be formatted on this unit Check the export device before you proceed Export can not be executed while the backup is in progress You can view the exported data with the supplied Archive player soft ware When you export the recorded data the audio data will also be export ed When you export the recorded data the Archive player program will also be exported in the ArchivePlayer folder of the device The exported data file name is made automatically as the Channel name_export date_ export time exp type Do not remove the USB device while the export is in progress it may cause a malfunction If you reuse the removed device you must format the media by using erase media options The warning message appears for the conditions listed below When the start date time and end date time are the same value When the start date time is later than the end date time The export media does not have enough space When you set the time for data that does not exist An external media has to be formatted on this unit to prevent a malfunc tion
25. i o Motion Rec eo imal 0 Figure 3 16 Video adjustment setup menu Channel Selects the desired channel to adjust Brightness Adjust the brightness value from OO to 100 for the selected channel Contrast Adjust the contrast value from OO to 100 for the selected channel Color Adjust the color value from 00 to 100 for the selected channel FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 37 3 19 3 PTZ Settings for the PTZ cameras connected via the data port of the biphase connecter or RS 422 485 terminal Cameti Ta Camera Wieden mdj Continocus Aeg istant Aaz input Aee Motion Fae Viden formai Figure 3 17 PTZ setup menu Camera Selects the desired camera to set the connected PTZ camera COM port Selects the connected data port of the biphase connecter or RS 422 485 terminal on the rear panel Control ID Selects the PTZ camera ID from 00 to 255 Make the same settings as the PTZ camera Protocol Selects the protocol supported by PTZ camera Baud rate Selects the communication speed 1200 2400 4800 9600 19200 or 38400 PTZ test After the PTZ setting you can test the pan tilt function for the selected PTZ camera You can see the test screen from the preview windows on the right side of the PTZ test option lt gt Test the pan direction A F Test the til
26. or 200 Language Select the language for Control Center program e Tools Connection Infomation To register a site name e Help Control Center Information Displays Control Center Version Information 2 Mode Selection Icons e Live Mode 2e Camera View You can see the surveillance camera s images in the window s and the camera information Pan Tilt Zoom You can control the PTZ cameras Log View Displays system log list e Search Mode si You can search the recorded data as shown below FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 85 Date Time Search See 6 6 1 Using the Date Time Search function Event Search See 6 6 2 Using the Event Search function Bookmark Search See 6 6 3 Using the Bookmark Search function Smart Search See 6 6 4 Using the Smart Search function j e Remote Setup Mode You can set the configuration of the unit Camera Display See 6 7 1 Camera Display setup Schedule See 6 7 2 Schedule setup Event See 6 7 3 Event setup Network See 6 7 4 Network setup System See 6 7 5 System setup Screen Mode Selection Icons PERS EEEE E EEEE When the icon is clicked the screen will be changed to multiscreen view If the icon is clicked again the screen will be changed by sequence You can view the live window s in full screen view To return to the normal screen right click the mouse Sequence Icon
27. playback KIH Select the required scanning speed A Starts instant playback in selected channel j Stop playback Live Screen Displays the current surveillance live screen Displays the current date and time Note Digital Video Recorder Displays the lock menu to change the user type or disable system operation w Displays the screen division selection window for the monitor A E Displays the screen division selection window for the monitor B Click at a desired point to be marked during playback Up to 15 points can be Click the right button on the mouse to display remove the system control bar displayed on screen User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 27 3 14 Selecting live screen mode 3 14 1 Monitor A You can select the live screen mode to display a full 4 view 6 view 8 view 9 view or 16 view screens on the main monitor ae Press A button or click the e icon in the system control bar The screen mode select menu of monitor A is displayed on the monitor A 2 Select screen mode 5 E 9 410 11 12 13 44 15 16 EEEEEREEREEEEREEREEREEEEENEEN ENN EE EEEEEREEMEEREEEMEEREEEEEEEEEEEEEENEH XE EE Figure 3 9 The screen mode select menu of monitor A Selected channel of the monitor A Channel buttons Press the 1 to 16 channel button to see the current camera images in selected live screens
28. sec 70 sec 80 sec or 90 sec 3 21 3 Monitor B Event popup Figure 3 36 Monitor B setup menu FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 51 Seq dwell time You can set the camera sequence time to 2 sec 5 sec 10 sec 20 sec 30 sec 40 sec 50 sec 60 sec 70 sec 80 sec or 90 sec Event popup Displays an event popup on the monitor B if motion input or all motion or input occur 3 22 Event settings 3 22 1 Input Fucr am se a e A Motin Selec Em gcin Cami Amlay QUID Figure 3 37 Input setup menu In Displays the number of inputs Input type The input state can be set to either N O Normally Open or N C Normally Closed Camera Select the connected camera channel to the input Relay output Select the relay output number for the selected input Bosch Security Systems User Manual FO1U 1 0 2007 12 52 en Connections and settings Digital Video Recorder 3 22 2 Motion Sanaitrvity Halay output Ares Figure 3 38 Motion setup menu Camera Select the camera to set motion detection Sensitivity Set the level of sensitivity for the created motion detection area Sensitivity can be set from level O1 to 10 or Off Relay output Select the number of the output relay when motion is detected Area Select the desired motion detection area on the preview window screen lt 4 gt A Y
29. the operating instructions Improper adjustment of other controls may cause damage to the unit Use of controls or adjustments or performance of procedures other than those specified may result in hazard ous radiation exposure 8 Overloading Do not overload outlets and extension cords This can cause fire or electrical shock 9 Power cord and plug protection Protect the plug and power cord from foot traffic being pinched by items placed upon or against them at electrical outlets and its exit from the unit For units intended to operate with 230 VAC 50 Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 10 Power disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source The power cord is the main power disconnect device for switching off the voltage for all units 11 Power sources Operate the unit only from the type of power source indicated on the label Before proceeding be sure to disconnect the power from the cable to be installed into the unit 12 Servicing Do not attempt to service this unit yourself Opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service per sonnel 13 Damage requiring service Unplug the unit from the main AC power source and refer servic ing to qualified service personnel when any
30. you observe any of the following symptoms e Some of the front panel LEDs do not light e The DVR does not operate normally You can reboot the DVR as follows e Turn off the DVR and turn it on again after a few seconds When the recorder does not work normally after rebooting contact the service center Bosch Security Systems User Manual FO1U 1 0 2007 12 118 en Reference Digital Video Recorder 8 2 Recommended devices 8 2 1 Supported USB Memory list No Maker Model Name Capacity USB Version 8 2 2 Supported CD DVD Media list maker on conw ovon ovonw ovos ovoeRW Note 8cm 1 4G mini DVD is not supported 8 2 3 Supported function list for device Instant Schedule Configuration Import backup backup Export CD DVD Note If you use a USB memory stick or USB HDD for configuration import export you must disconnect the other external USB devices FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder 8 2 4 Protocol Name BOSCH PELCO D PELCO P GANZ_DSCP GANZ_P360V1 LG_MULTIX LG SD168 KALATEL_ CYBERDOM SALATER PANASONIC_ CS850 PANASONIC SAMSUNG_SCC SAMSUNG Bosch Security Systems Reference en 119 Supported PTZ camera list ES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES User Manual FO1U 1 0 2007 12 120 en Referen
31. 1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 61 3 24 3 Beeper Update Conhiquration Hart gisk input beeper Moton Soeper Syatem tenet Figure 3 47 Beeper setup menu Button beeper On Makes a sound when using the buttons Off Turns off the button beep Input beeper On Makes a sound when a input is activated Off Turns off the input beeper Motion beeper On Makes a sound when a motion is detected Off Turns off the motion beeper System beeper On Makes a sound when a cooling fan is not activated or the HDD has a bad sector Off Turns off the system beeper Note The beeper is a low sound on this unit If you want to make a loud sound connect an external alarming device to the output connecter ext siren Bosch Security Systems User Manual FO1U 1 0 2007 12 62 en Connections and settings Digital Video Recorder 3 24 4 User You can register a new user with various access rights to the DVR or Control Center 2 Date Time NTP Bee per Undate Configuration Hard dist Backup Gvatem Figure 3 48 User setup menu No Displays the user number ID Enter the new user ID using the virtual keyboard Level Select the level of the new user Password Enter or change the password for the user using the virtual keyboard You can use the password with number special character or ch
32. 2007 14 25 07 be Mobion detected D Everk mpat 1106 2007 4 25 37 R08 Hotin detected C Evet repat 11 06 2007 14 40 967 Motor debectad C Evert repot 11 200 Laaa G Motion detected C Evert mpat 11 08 2007 422448287 Motion debarbed T Evert repork 11408 2007 14224 46 259 Molim debected 1 fEverk repot 11 02 2007 1701 40 140 Mobon detected Everk repat 11 02 2007 F501 46 1 12 Motion detected j Everk rpk 11 02 2007 170147089 Holin debeched Everk report 11 02 2007 1700 77 00 Hoton detected I Evert repet 1102 2007 17 00 35 2208 Motion detara Everk report 11 02 2007 7200 16 84 Motion detected Everk report 11 08 2007 L700 16 742 Mobon detected 1I Everk repet 11 02 2000 Pott 10 636 Minton detertad Evek reset 1102 2007 LPs 10 6LF Holin debetbed Erant report 11 02 2009 L002 10 991 Mobon detected C Evert report 1 02 2007 16 59 419 566 Mohon detected T Evert report 11 02 2007 Lecve 49 5c Moton detected Eri repat 11 02 2007 16 99 449 540 hinhin daterte Everk raiat 11 02 2007 16 59 24 9805 Holin detected T Event report 11 02 2007 1 Gco9 24 400 Mobon detected Evert report 11 e 2i 14 25 42 272 Motion detected we 168 0 58 O82 LOD 2 LEAL 16 92 168 0 16 12 LGU IG ea LBRO I 192 1680 16 192 16H 0 06 192 168A 192 166 0 16 oe 22 LEU ol te ERD ool 92 1680 1 oof 32 LOU EG wolf LBRO 16 ol 32 LGB i5 ool FE LOUD BG ol
33. 8 68 54 34 27 102 82 51 41 97 77 48 39 Note This recording time table is for reference only The recording time can be different depending on your surveillance environment FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 129 8 7 Specifications 6 1 Input Composite video 0 5 2Vpp 75 ohm automatic termination Loop Through ooe eee Video Mon A CVBS 1 0Vpp 0 1V 75 Q Output i Mon A VGA Analog RGB 800x600 Mon B CVBS 1 0Vpp 0 1V 75 Q ee ee ee ee Input f Line In 30KQ Audio Output Line 100 KQO Ooo 8 O O Input Opto coupled alarm input Max 5V Output 1A 30V DC 0 3A 125V AC Pre Alarm Recording Up to 60 sec Up to 240 IPS 352x240 Up to 480 IPS 352x240 NTSC Up to 120 IPS 704x240 Up to 240 IPS 704x240 5 di Up to 60 IPS 704x480 Up to 120 IPS 704x480 ecorain i Up to 200 IPS 352x288 Up to 400 IPS 352x288 PAL Up to 100 IPS 704x288 Up to 200 IPS 704x288 Up to 50 IPS 704x576 Up to 100 IPS 704x576 7 h Playback Function FF FB Frame Advance earc Search Mode Date Time Event Motion Input Bookmark Smart NTSC 240 IPS 480 IPS Real time per each channel Real time per each channel PAL 200 IPS 400 IPS Real time per each channel Real time per each channel Multiscreen Mode 1 4 9 1 5 1 4 9 16 1 5 1 7 pike Max Capacity 2TB Up to 4 HDDs a USB 2 0 x3 Network USB Memory CD
34. 85 2703 2162 1352 1081 J5 e pl 241 193 770 216 350 280 Low 5 13 el 7 5 6 963 770 481 385 1048 838 524 419 1185 948 593 474 979 784 490 392 il 1926 1541 963 770 1436 1149 718 574 30 25 321 257 160 128 304 243 152 121 20 20 342 274 171 137 323 258 161 129 15 12 5 550 440 275 220 501 401 251 201 Normal 352x240 352x288 FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 125 Recording Time Hr VideotAudio NTSC PAL Video NTSC PAL Resolution IPS Quality NTSC PAL oo NTSC PAL DVR 8L DVR 16L DVR 8L DVR 16L 704x240 Norma Bosch Security Systems User Manual FO1U 1 0 2007 12 126 en Reference Digital Video Recorder IPS NTSC PAL Resolution NTSC PAL NTSC PAL NTSC PAL DVR 8K DVR 16K DVR 8K DVR 16K DVR 8L DVR 16L DVR 8L DVR 16L LOL 220 176 110 88 212 169 106 85 High Recording Time Hr Video VideotAudio Quality 126 104 138 114 106 85 151 124 8 6 Recording Time Table 160GB HDD Recording Time Hr Resolution IPS Video Video Audio NTSC PAL Quality NTSC PAL NTSC PAL NTSC PAL DVR 8K DVR 16K DVR 16K DVR 8L DVR i6L DVR 8L DVR 16L 80 64 352x288 T FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 127 Recording Time Hr Resolution IPS Video Video Audio NTSC PAL Quality NTSC PAL NTSC PAL NTSC PAL DVR 8K DVR 16K
35. Connection board for Alarm I O and Biphase Figure 2 1 Accessories FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder 2 3 Introduction en 11 Front panel DVR 16K DVR 16L lt E 0 ZNA 3 3 i INFO FOCUS FO Owe 6008 mwwm YE ZNA pl COPY 0 be 2 z xX J E Sees Serer weeccccecercccccerccsccsoeesccsoeeee eeoscocococooocoooo ococococsooocooooo LOCK ZOOM YE MOVE ie eqete ics es ae S eecccreccccccceltecescceecceoeee eeeeccccesecccccs 2 2 2 4 5 z 2 gt SET o C eocscccore Figure 2 2 Front panel L FUGEVE Bl Bosch Security Systems Arrow Buttons lt gt A VY Select or move between the menu options ENTER Confirms menu selections Function Buttons Displays the setup menu Display the monitor A control menu to set the screen mode to full 4 6 8 9 or 16 screens Set the video output signal to VGA mode Display the monitor B control menu Set the video output signal to MON A mode Switches the unit to PTZ mode to control the connected PTZ camera Press to see different multiscreen modes View all channels in sequence Displays the search menu Starts or stops instant recording of the selected camera y
36. IS To manually adjust the iris of a camera PRESET Displays selected preset numbers To input the preset number Table 6 1 Virtual remote control button table Notes e If someone is controlling a PTZ camera using the DVR you cannot use the PTZ function and vice versa e You can not use the PTZ function when you log in with a normal user ID To Register preset positions iy 2 3 FO1U 1 0 2007 12 Move the camera to the point you wish by using the A W lt gt Click the SET icon Select preset the number you wish to register Click the The position and its numbers are memorized icon Repeat steps 1 4 to add additional positions User Manual Bosch Security Systems Digital Video Recorder Control Center en 89 Note The preset range is available from O to 255 on this unit However the actual preset range differs depending on the PTZ cameras Changing to a picture in a preset position The following function is available only with cameras equipped with the preset function The preset function makes the PTZ camera move to the programmed preset position It is necessary to program preset positions for the PTZ camera beforehand 1 Click the MOVE icon 2 Use number icons to enter the memorized preset position s index number Click the icon l The camera moves to the preset position and the picture from the camera in that position appears on the monitor To clear the preset posi
37. NULL Alarm on O Motion detect Off Disk full O Admin PW changed O Video loss O Power on off O Notification Off SMTP server NULL SMTP port no User name Password TLS Mail address 1 Mail address 2 NULL Mail address 3 NULL Notification Off IP address NULL Port no 9002 100 Mbps DDNS NULL Network Notification H mh Gana Bana hh ah NO NULL NULL O NULL Mail Emergency 5 O P 02 N JA JA IA JAN JA JAN JA JIN JAN AN JIA JAN IAN JAN JAN IAN JA IN N A A FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 123 Oo me o oo Beeper Cow 0 YS b 0 w v User Update import configuration YS C Factory defaults SY eves o o C Time range date o0 ws Timerange start 0O Ys C Time rangeend o0 Bosch Security Systems User Manual FO1U 1 0 2007 12 124 en Reference Digital Video Recorder Recording Time Hr Video Video Audio NTSC PAL NTSC PAL DVR 8K DVR 16K DVR 8K DVR 16K 8 5 Recording Time Table 500GB HDD DVR 8L DVR 16L Resolution Qualit IPS NTSC PAL y NTSC PAL DVR 8L DVR 16L 501 401 251 201 275 720 285 228 518 415 259 207 116 853 Lowest 726 581 363 290 7 5 6 1185 948 593 474 979 784 490 392 1427 1141 713 571 1139 911 569 455 1313 1051 657 525 1828 1462 914 731 444 355 222 177 493 395 247 197 623 498 312 249 823 658 411 329 884 707 442 354 5 1712 1370 856 6
38. Use to increase the options value Click the icon on the bottom of the on screen display with the left mouse button to h display a setup menu 2 Click the desired menu icon with the left mouse button to display the submenu g Click the desired submenu item with the left mouse button 4 Set the selected options value B Click the Exit icon to exit setup menu If the save message appears click OK with the left mouse button to save the settings 3 18 2 Setting the menu using the front panel buttons or remote control but tons o Arrow Buttons A VW lt 4 P Use these buttons to select the menu options or adjust the options value ENTER Select the option or confirm the setting ESC Return to the previous menu or level 1 Press SETUP im to display the setup menu we Use lt P gt to select the desired menu icon d Use A F to select the desired submenu item then press ENTER to display the setting options 4 Use A W lt 4 gt to select the desired option then press ENTER to set the value D Use lt P gt to select the desired setting then press ENTER to confirm your selection 6 Press ESC to exit the Setup menu If the Save message appears press ENTER to save the settings Note When you operate the function menu by using the remote control and front panel buttons both buttons are operated in the same way to control the function menu To use other functions of number buttons on the front panel as shown
39. VE Moves the PTZ camera to the preset position e 16 TOUR Tours all registered preset positions in the PTZ camera Shuttle Ring Fast forward or reverse picture search when the dial is rotated 6 JOG Dial Allows a forward or reverse frame search In pause mode plays recorded images frame by frame through rotation Increases or decreases the options value ESC Use to return to previous level or to exit menu system without saving E Playback Control Buttons I Pauses playback dq Reverse search the recorded images lt gt Playback or reverse playback of recorded images gt gt Forward search the recorded images W Stops playback E _siIndicators Lights when the DVR is powered amp Blinks when the HDD is accessed Lights when the alarm is active Lights when a network cable is connected USB Port Connect an external USB device for back up or playback Remote Sensor Point the remote control here ALT Activate if you use the Sub function of the channel button FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Introduction en 13 2 4 Back panel DVR 16K DVR 16L POPC OTTSC HOSES CETTTC SOLS OOTTT OSLO OHO TTTEOOO OHS CTTSO OTOL SETTER ES COHTTOS SOOO HTTTOOO ESOS ECTS OHO SO OOTESOS SOOO TESOSOSOTOTSTE SOHO SO esT ESOS SOOO ST OSS OOSOTETSCO SOOT OSTEO TS 66 6 6 666606666060660s 0 00000 00007 L cocoocoocococooccocoococooooooo
40. ancel the selected area Select the all area Figure 6 22 The sensitivity level setting window Selected area within red box 2007 LLOER IAA 27 Figure 6 23 Selected motion area T Click the search icon The smart search data is displayed FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 95 Charme Seach Lis BPEL dijas aiiha adhe Tenet 14d bo Genedl itn Figure 6 24 The searched data list 8 Select the channel from the list 9 You can play the searched data using the playback control buttons 6 7 Remote Setup mode You can set the DVR of a selected site name in the remote setup tab via the network 6 7 1 Camera Display setup Figure 6 25 The Camera Display setup window Bosch Security Systems User Manual FO1U 1 0 2007 12 96 en Control Center Digital Video Recorder Camera Setting Figure 6 26 The Camera setting window FO1U 1 0 2007 12 Select a channel for settings If you want to block a channel from other users mark up the convert option Enter the new channel name Select input audio channel Set the PTZ control options COM port Select the connected data port of the RS 422 485 terminal on the rear panel Control ID Select the PTZ camera ID from O to 255 Make the same settings as the PTZ camera Protocol Select the protocol supported by PTZ camera Baud rate Select the communication speed 1200 2400 4800 9600 19200
41. aracters minimum length 4 maximum length 8 Note Remember the password If you forget the password please contact an authorized service center or the dealer you purchased the system FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 63 3 24 5 Update The update feature allows you to upgrade DVR software and add upgrade PTZ protocols In this case the current DVR settings are not deleted or replaced during the update process Date Time MTF Beeper UTET Configuration Haft izk Mathod Backup oyatem Uodate Figure 3 49 Update setup menu L Select one of the following e Select System firmware to upgrade DVR system software e Select PTZ protocol to update the DVR protocols 2 Choose the media from which to perform the update e USB Select USB and then insert the USB drive into the DVR All USB devices must be disconnected before you can use the USB drive e Network Select Network and then do the following a Select the update server settings box The virtual keyboard is displayed b Enter the update server IP address The DVR network settings must be configured and you must know the update server s IP address Select Update to start the update process Select OK to begin the update process or click Cancel to stop and exit After the update process is completed the system displays the Restart the system dialog box 5 Click OK to restart
42. below Le 2 Press ALT The button indicator turns green Select the function button you want All the operation explanations are based on using the remote control FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en Camera settings Camera The camera name covert and input audio channel settings are configured ii Move Video anj Enter Select PT7 E tati Contintows Ree r a ale GAMES instant Aec Le ai r Ta Jp 3 inaut Fee Motion Ane th Covert Augio Video format Camera i FF aC CS 2 ie 7 GS J or f 0 4 a a i a 6 Ez a a re a Figure 3 15 Camera setup menu Ch Displays the channel number Name Enter the camera name using up to 12 characters 4 gt A V Select a character ENTER Confirms your selection ESC Exits the virtual keyboard menu Covert You can set the camera conditions to prevent operation by other users Audio You can hear from the selected input audio channel 35 Bosch Security Systems User Manual FO1U 1 0 2007 12 36 en Connections and settings Digital Video Recorder 3 19 2 Video adjustment Adjust the brightness contrast and color settings of each camera channel You can see the settings screen from the preview windows Camera i b Move fides Enie Select PTZ Exit Continuous Rec Camera Video adj instant Aec Input Hee Camera t O O sdY amera
43. ce Digital Video Recorder 8 3 Time zones Timezone name Timezone Timezone DST Abbreviation Eniwetok Kwajalein 12 00 Midway Island Samoa 11 00 10 00 09 00 08 00 Pacific Time US and Canada Tijuana 08 00 07 00 Mountain Time US and Canada Chihuahua La Paz MST 07 00 06 00 Mazatlan Arizona Central Time US and Canada Saskatchewan pen E Guadalajara Mexico City Monterrey Central America A pe Sachs Eastern Time US and Canada Indiana East Bogota EST 05 00 04 00 Lima Quito Atlantic Time Canada Caracas La Paz Santiago 04 00 Newfoundland 03 30 02 30 Brasilia Buenos Aires Georgetown Greenland 03 00 Mid Atlantic 02 00 Azores Cape Verde Islands 01 00 Greenwich Mean Time Dublin Edinburgh Lisbon GMT 01 00 London Casablanca Monrovia Amsterdam Belgrade Bratislava Budapest Ljubljana Prague Sarajevo Skopje Warsaw Zagreb Brussels AMS 01 00 02 00 Copenhagen Madrid Paris Berlin Bern Rome Stockholm Vienna West Central Africa 03 00 03 00 Helsinki Riga Israel Kyiv Sofia Tallinn Vilnius 03 00 04 00 04 00 04 30 Aea na Colombo Astana Sri Jayawardenepura ADC Perth Singapore Taipei Beijing Chongqing Hong Kong SST SAR Urumqi Kuala Lumpur Irkutsk Ulaan Bataar 12 00 FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 121 8 4 Factory default configuration settings Factory DVR 16K DVR 8K 1st level 2
44. change the monitor type the system will be rebooted automatically 3 13 General explanation of the live screen on the main monitor Main monitor screen sake M pum x 4 zy u a Ei ZENE XE x4 COSCO CCOCSCSSOCOSOOOOOOOOOCOOOOCOSOOOSOSSOOCOCOCOCOOO izp i _ it kann ia i P ee i 7 i OO 8 2 8 6 8 8 Oo 6 6 x s ge te one oa TJ Figure 3 8 Main monitor screen Bosch Security Systems User Manual FO1U 1 0 2007 12 26 en Connections and settings Hi o g D amp FO1U 1 0 2007 12 Channel Number Displays the channel number Camera Name Displays the edited camera name Recording status icon Displays the recording status e Red Dot icon indicates Instant recording e Yellow Running man icon indicates motion detection recording e Red Alarm bell icon indicates input triggered recording Selected Channel Displays the selected channel with yellow box System Control Bar Displays the setup menu Displays the search menu Displays the PTZ remote control window Displays the system log list window Displays the system information window ee ey Turns the alarm off marked P i h i i Display copy export menu Displays the remaining HDD status N Normal partition Used size total size E Event partition Used size total size Pause
45. channel for event search Select the event type Click the search icon FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 93 The event list is displayed 6 Select the event from the event list T You can play the searched data using the playback control buttons 6 6 3 Using the Bookmark search function Search the desired picture with a registered bookmark using the bookmark function BEER gt Mp Salacted Curae Figure 6 19 The Bookmark search window 1 Select the bookmark search tab 2 Click the search icon All bookmark data is displayed in the list Select the data in the list Play the searched data using the playback control buttons 6 6 4 Using the Smart search function Picture recorded via motion detection can be searched by specifying the motion detection conditions Figure 6 20 The Smart search window Bosch Security Systems User Manual FO1U 1 0 2007 12 94 en Control Center Digital Video Recorder 1 Select the Smart Search tab 2 Click the date icon and select the day The selectable days are displayed in blue color Select the camera channel Select the start time using the timeline OO O1 O24 03 OF OF 06 OF OF iQ 11 l2 13 14 15 16 17 16 19 20 21 22 23 Figure 6 21 Selected start time Dy Select the end time 6 Select the motion sensitivity level and motion area on the display window using the mouse C
46. ckup iL oS a SS a FO1U 1 0 2007 12 Connect the USB device for backup You cannot use the CD or DVD writer for daily or weekly backup Select Weekly or Daily on the schedule options Select the backup device Enter the date and or time to start backup on the schedule start option Enter the day of week and or time on the Time Range Start option Enter the day of week and or time on the Time Range End option Select Estimation size icon and press ENTER Check the size of selected data and free space of USB device If the USB device does not have enough space change the USB device of enough space or erase the connected USB device Note You cannot stop the backup while in progress The warning message will appear for the conditions listed below When the start time and end time setting are wrong A media does not have enough space When you set the time for data that does not exist When the selected USB device is disconnected The estimated size of backup data is only the approximate size Be sure to allocate sufficient space on the media to accommodate the backup task You can check the backup status on the system control bar The scheduled backup will not start if there is an export or a search of the external USB device in progress After the export or backup search is finished scheduled backup will be restarted When you set the schedule backup the backup data size is estimated from the recording settings of
47. composite monitor the OSD quality may lower to read it User access rights User Level administrator Advanced User Normal User Table 3 4 User access rights 3 12 Selecting the main monitor type You can select the main monitor type to display the main screen during power on 3 12 1 Using the VGA monitor 1 Connect the VGA monitor to the VGA connector on the back of the DVR 2 Turn on the VGA monitor 3 Press and hold the A button on the front panel until the beep sounds to display the main screen The DVR will restart and then the VGA monitor is set as a main monitor N a ees Seis ie seeeeee ees peewee st eerereeree F See Figure 3 6 The A button on the front panel 3 12 2 CCTV composite video type monitor 1 Connect the CCTV monitor to the MON A connector on the back of the DVR 2 Turn on the CCTV monitor om Press and hold the B button on the front panel until the beep sounds to display the FO1U 1 0 2007 12 main screen The DVR will restart and the CCTV monitor is then set as main monitor User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 25 oS ARE AA ae wee eee pe eeee2eoee ie BOSCH P oe gt 00000 Figure 3 7 The B button on the front panel Note You can select the monitor type by using the A or B button at any time If you
48. configured automatically by the DHCP server If you set to ON the IP Address Subnet Mask Gateway Primary DNS and Secondary DNS options are dimmed and these options can not be set Off Enter the network settings manually IP address Enter an IP address using the virtual keyboard Subnet mask Enter a subnet mask address using the virtual keyboard Gateway Enter the gateway address using the virtual keyboard Primary DNS Enter the Main DNS server address using the virtual keyboard Secondary DNS Enter the Sub DNS server address using the virtual keyboard Remote client port no Enter the remote client port number using the virtual keyboard You can watch the live surveillance image over the network with the Control Center program The factory default port for transmission of video and audio data is 9001 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1025 65535 HTTP port no Enter the HTTP port number using the virtual keyboard You can watch the live surveillance image over the network with a web browser Typically the TCP port used by HTTP is 80 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 80 or 1025 65535 Bandwidth limit Enter the Bandwidth to adjust the data traffic Note When you change the Remote client port or HTTP port number all co
49. confirm it Select the Update icon then press ENTER The search result is displayed in the time table of the search menu oe ee Use the channel buttons on the front panel to select the channel s you want to play back f Press lt gt or Click the Play gt icon to start playback The picture s is are displayed in the main monitor Figure 5 5 Playback showing system control bar 8 Press STOP W to stop playback and return to the search menu 9 Press SEARCH or ESC to exit the menu Bosch Security Systems User Manual FO1U 1 0 2007 12 76 en Search and playback Digital Video Recorder Notes e Recorded data shown on the time graph will be displayed in different colors depending on the recording type Green Continuous Instant recording Red Input recording Blue Motion detection recording Gray No recording e Use the ZOOM button to view the detailed time by 6 hour intervals 5 2 3 Event Search Search a recorded picture by date and type of event INTERNAL MDD Figure 5 6 Event search menu 1 Select the Event Search menu 2 Set the year month day and time A W lt 4 Moves to the previous or next column or changes the setting at the current position ENTER Selects the column or confirms the setting Select the channel for event search using ENTER Use A W lt P to select the Event type then press ENTER Select the Search icon then press ENTER The event lis
50. corder FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 115 8 REFERENCE 8 1 Troubleshooting Check the following guide for the possible cause of a problem before contacting service Symptoms Resolutions The system power does not turn on The system power is turned on but no video data is displayed on the monitor The camera numbers are displayed on the screen but the camera images are not displayed The camera video is shown on the screen but the system does not record the video It is impossible to search through the recorded video Bosch Security Systems Check that the power cable is connected correctly Check that the input voltage is correct If the system power does not turn on even if the power cable is connected correctly please contact the service center Check that the monitor power cable is connected properly Make sure the monitor is turned on Check the video output cable of the DVR is properly connected to the monitor Check the selected monitor type see 3 12 Selecting the main monitor type Unplug the power cable and plug in again Check that the camera video output is connected to the DVR system correctly Check that the power cable on the camera is connected correctly Check the video cable connection from the camera to the DVR system Turn off the DVR system and turn it on again Check the recording mode in the reco
51. ct and set the operational conditions by using the buttons on the front panel the remote control or using a USB Mouse connected to the unit Only administrator level users have permission to access the Setup menu and configure the DVR Cameta pec TO S SSSSSSSSSCOSSOCOCOSE Te a oy jer gt a o gt a T w Videa adj r Pl Continuous Rer instant Aeg input Aez Motron Rec PSS SSSSSSOSSSOOSSOSOSOSOOOEOEOSO SE Video fonnal rest tte Me ee oe Fria o aa ee seterectel 5j Dele oe ieee eee De Ch Namo Covert RET Camera 0I OOO OOOO O Camera Oo oo O r Of j 0 of o E of f o Camera EI O O O i O a al m M x o lal lal o lal o o o o lal o lal lal CE a ee T r K TTT TCT TTT eet Figure 3 14 DVR setup menu oof E Eni Displays the selected main menu title Displays the main menu icons Displays the submenu options Displays the help menu Displays the selected submenu title Displays the detail options for selected submenu User Manual PSSOSOSOSOSSSSOSSOSOSOSOSOOSOOSCOCOCCOCO SS Bosch Security Systems FO1U 1 0 2007 12 34 en Connections and settings Digital Video Recorder 3 18 1 Using a mouse to set a menu Use the left and right mouse buttons to set the menu e Left button Use to select a required item or decrease the options value e Right button
52. ction Select the items for updating PTZ Protocol Set to PTZ Protocol update System firmware Set to System software update Method Select the update method USB Update from USB memory stick Network Update from the update server Update server Enter the IP address of the update server Note If you can not update from the update server check the TCP IP options and the IP address of the update server User settings Add User You can add user im Click the Add button User Setting window is displayed 2 Enter the User ID and Password 3 Enter the password again to verify A Select the user level and then click OK to confirm your selection Edit the registered User You can change the User ID password or user level 1 Choose the user ID and then click the Edit button 2 Change the ID Password or User level then click OK to confirm your selection Delete registered User ip Choose the user ID you want to delete 2 Click the Delete button FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Additional programs en 105 7 Additional programs 7 1 Alarm Notifier program If you set the notification in the emergency option to On the system sends a message according to the settings of the notification options in the setup menu See 3 23 3 Notification dls Double click the Divar MR Alarm Notifier icon to start the emergency agent program
53. ction 60 Permanently connected equipment Incorporate a readily accessible disconnect device in the build ing installation wiring Pluggable equipment Install the socket outlet near the equipment so it is easily accessible Power disconnect Units have power supplied whenever the power cord is inserted into the power source The power cord is the main power disconnect for all units Rack mount Ventilation Do not place this unit in a built in installation or rack without proper ventilation or adhering to the manufacturer s instructions The equipment must not exceed its maximum operating temperature requirements Mechanical loading Properly mount the equipment in a rack to prevent a hazardous condi tion due to uneven mechanical loading SELV All the input output ports are Safety Extra Low Voltage SELV circuits SELV circuits should only be connected to other SELV circuits Video loss Video loss is inherent to digital video recording therefore Bosch Security Systems can not be held liable for any damage that results from missing video information To minimize the risk of lost digital information Bosch Security Systems recommends multiple redundant recording sys tems and a procedure to back up all analog and digital information FCC amp ICES Information residential applications U S A and Canadian Models Only This equipment has been tested and found to comply with the limits for a Class B digital device
54. daily The backup data will be automatically saved according to the setting Device Select a backup device Schedule start Set the schedule start date a day of the week and time Time range date Enter the backup time range Enter the date you want to backup Time range start Enter the start day of the week or time Time range end Enter the end day of the week or time Estimate size Displays the size of backup data and the free space of external devices Start backup To start backup Erase media To erase the media User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 67 Notes e The backup function is not supported on the external USB CD ROM drive e Backup to external USB HDD is supported with maximum 250 GB e Use the recommended external USB devices for preventing malfunction See 8 2 1 Supported USB memory list e The CD R DVD R or DVD R discs cannot be formatted e An external media has to be formatted on this unit to prevent malfunc tion e DVD RW and DVD RW discs have to be initialized before using e You cannot use the Estimate size Start backup and Erase media options in backup progressing e Do not remove the USB device while the backup is in progress it may cause a malfunction If you reuse the removed device you must format the media by using Erase media options e If you format the external media by using a PC with FAT32 the media may not be used on thi
55. damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance Bosch Security Systems User Manual FO1U 1 0 2007 12 4 en Safety 14 15 16 LT Digital Video Recorder _ unit does not operate normally when the user correctly follows the operating instruc tions Replacement parts Be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substi tutions could void the warranty and cause fire electrical shock or other hazards Safety check Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operating condition Installation Install in accordance with the manufacturer s instructions and in accordance with applicable local codes Attachments changes or modifications Only use attachments accessories specified by the manufacturer Any change or modification of the equipment not expressly approved by Bosch could void the warrantee or in the case of an authorization agreement authority to operate the equipment 1 2 Safety precautions DANGER High ris
56. e Player icon on the PC or Archive Player folder of the external USB device If you insert the exported data CD or DVD disc the Archive Player program run automatically The Archive Player window is displayed Select File F gt Open The open window is displayed Loni ri C Areheve plage ne fh cr EF hy Degi mi My Meshes Figure 7 8 The open window Select the root directory of the USB device and select the desired file An example of playable file format is Channel name_date_time exp Click the Open button The selected data is played back automatically Bosch Security Systems User Manual FO1U 1 0 2007 12 110 en Additional programs Digital Video Recorder Figure 7 9 The Archive Player window on Click the z button to stop playback FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Additional programs en 111 7 4 Web Viewer program 7 4 1 Logging into the Web Viewer ie Start the web browser 2 In the Address Box enter HTTP and the IP Address of the DVR Address 4 htp 192 168 0 16 o Press ENTER then the Web Viewer and the Remote log on menu will be displayed Remote log on Site Address 192168016 Fort 3001 User Type Password Cancel Figure 7 10 The Remote log on menu 4 Enter the User Type and Password 5 Click OK Notes e Ifthe web viewer is not displayed check the TCP IP settings of the DVR e If you connect
57. e network interface via DHCP Manually configure network The DVR may be manually configured by assigning an IP address subnet mask gateway DNS Connecting the USB device USB memory device Insert the memory device into the USB port The system automatically recognizes the device Using a USB memory device the system software can be easily upgraded USB backup device Connect the USB cable of the USB backup device to the USB port on the rear panel of the unit Example HDD or other external storage Mouse Connect the USB mouse for function control of the unit Bosch Security Systems User Manual FO1U 1 0 2007 12 20 en Connections and settings Digital Video Recorder 3 8 Connecting a RS 422 485 device Use this port to connect PTZ cameras or DVRs for example when the PTZ camera is connected Connect the PTZ serial communication lines to the RS 422 485 terminal Notes e When connecting lines connect the TX of the DVR to RX of the PTZ unit and TX of the DVR to RX of the PTZ unit correctly e Recommended initial data are 9600 Baud Rate 8 Data bits 1 Stop bit and No parity e When connecting PTZ cameras to DVRs it is necessary to set the setup menu for this unit according to the RS 485 settings of the camera and DVRs PTZ Units RS 422 485 TYPE Figure 3 2 RS 422 485 connections ae 1X4 DATA RX DATA Data Reception RX DATA Data Reception Table 3 1 RS 422 485 connections
58. e schedule Input Motion record is not set e HDD partition according to a recording type Normal Partition It is the space in the HDD that stores the continu ous and instant recorded data Once the normal partition is set to 0 the event partition is 100 you can not record the continuous or instant recordings Event Partition It is the space on the HDD that stores input and motion recorded data Once the event partition is set to 0 you can not record the alarm and motion recording e Priority of record Instant record gt Input record gt Motion record gt Continuous record User Manual Bosch Security Systems Digital Video Recorder Search and playback en 73 5 Search and playback 5 1 Playback It is possible to play a recorded image without stopping recording I Select a channel you want to playback 2 Press lt P gt to play a recorded image of the previous 2 minutes of recording The playback image will be displayed on the selected channel window n nN i h ae a Po ee Fa i o A PE 7 s Figure 5 1 Playback window 000000000099 I i Ee tia p6e0 6000o eeeeeeeeeds a Ee z4 A D N i ba i Z To bz a A i 3 Press W STOP to stop the playback Note The playback window is fixed and only in selected channel 5 2 Search The various search functions of this unit can be used to go to the beginning of the desired p
59. elected The camera position image will be switched on the active monitor 2 You can stop the tour by pressing the TOUR button or clicking the TOUR icon 3 15 6 Setup for PTZ cameras You can adapt the camera to your requirements by setting up the respective items in menus IR Click the SETUP icon The setup menu appears in the selected window of the main monitor 2 Use arrows ZOOM and ENTER buttons to set the options Notes e Refer to the manuals of the PTZ camera for more details e Some PTZ cameras may not operate correctly with this unit e You cannot control the other functions when the PTZ virtual remote con trol is displayed 3 16 Viewing System Information To view system information 1 Press INFO or click the INFO icon in the system control bar The system information window is displayed on the main monitor System Information System Model Name Serial Number Video Format MAC Address Network IP S W Version Micam Version Kernel Version Hard Disk Disk 1 Disk 2 Disk 3 Disk 4 Total Figure 3 12 System information window DVA T6L NTSC 02 04 AC ES 7 1 88 192 168 0 16 0 1 1 05 1 0 5 232 GB 237 GB NONE NONE 422 422 GB 2 Press INFO or click the Exit Info button to exit the window Bosch Security Systems User Manual FO1U 1 0 2007 12 32 en Connections and settings Digital Video Recorder 3 17 Viewing the System Log List To vi
60. ellow border Cancels alarm activation and returns the system to the condition before the alarm was activated User Manual FO1U 1 0 2007 12 12 en Introduction Digital Video Recorder Disc Tray DVR 8L and DVR 16L only Insert a disc here E Channel Buttons You can input a number with the channel buttons You can also use the channel buttons for sub function with ALT button The COPY IRIS SET CLEAR MOVE and TOUR buttons of 8 channel DVR are used for subfunction without ALT button e The LED in the button indicates the status as follows Off The current status is for live mode Red Recording mode Blinks when an event occurs e 1 OPEN Opens or closes the disc tray DVR 8L and DVR 16L only e 2 LOCK Displays the lock menu to change the user type or disable the system operation e 3 ZOOM 4 ZOOM Adjusts the zoom level of the PTZ camera e 5 LOG Displays or removes the System Log List e 6 INFO Displays or removes system information e 7 FOCUS 8 FOCUS Adjusts focus position of the PTZ camera e 9 COPY Copies the recording data to an external device e 10 MARK Sets the mark point for recording search You can set the mark point during the single channel playback of recorded data e 11 IRIS 12 IRIS Adjusts iris position of the PTZ camera e 13 SET Registers the PTZ camera s preset position e 14 CLEAR Deletes a memorized preset position of the PTZ camera e 15 MO
61. em ID of the DVR If you set the system ID to 0 you can control multiple DVR at the same time Bosch Security Systems User Manual FO1U 1 0 2007 12 16 en Introduction Digital Video Recorder FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 17 3 Connections and settings Precautions There are various ways to connect the unit depending on the camera and other equipment Please refer to the camera manual or the manuals for other devices as necessary for additional connection information Be sure to switch off the camera before installation and connection 3 1 Basic connection overview Ox aung oooo0oo0o0o0000 0000000000 Figure 3 1 Basic connection overview Bosch Security Systems User Manual FO1U 1 0 2007 12 18 3 2 3 3 3 4 en Connections and settings Digital Video Recorder Connect the cameras to the BNC loop through camera inputs automatically terminated Connect the Monitor DVR VCR or others to the video out BNC Connect the power cord to the unit E Connect an audio amplifier Connect a pan tilt zoom control unit via the supplied 15 pole D type connector board 6 Connect up to 16 alarm inputs or connect up to 8 alarm output rela
62. en the input is activated or motion has been detected 5 Select the next time cell block of schedule time cell blocks to confirm the schedule time Schedule Sun Edit EJ Prev Y 3 a E E 7 i E Lay copi H r i Exit Figure 3 25 Schedule setup menu 6 Press ENTER or click the left mouse button repeatedly to select gray to set the time for the end of the schedule The settings cell block is highlighted Schedule Sun re E gt rt hk mm mw Ff fF tf Th MM E cr Move Exit E Prev CLECECLCECCE i Ti mall La Ra Day copy cri i gm LA c py i E mig Figure 3 26 Schedule setup menu T Press MENU to confirm your settings The confirmation window is displayed 8 Select OK and press ENTER to save the new settings e Press ESC to exit the specific date selection menu FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 45 3 20 2 To set a recording schedule for an Exception days In addition to the weekly schedule up to 10 specific date time periods can be defined To configure the specific recording schedule select Specific Dates a Select the Exception days option Schedule ale ct Moue Select EA Eri Figure 3 27 Exception days setup menu 2 Select a cell block schedule Exception days ce Kinue Edit CES Pree p RR ol RT AT eal PE e Hina Hay Eog f Figure 3 28 Exce
63. era is properly connected Check that the selected channel to control the PTZ camera Check the user type The PTZ camera control is not available for a normal user FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Reference en 117 An e mail sent E mail reception failed without SMTP server setting from this product Make sure the network is correctly set was not received Make sure the mail address is input correctly Check the spam mail setting of the inputted mail address If you set the spam mail some mails are deleted automatically or classi fied in the spam mail box Some of SMTP mail services do not support e mails from private SMTP servers In this case use the public SMTP server E mail reception failed even if the SMTP server was set e When the Please check the SMTP information or internet cable mes sage is displayed Check the SMTP server address Check the SMTP port number Default setting is 25 Check the network settings When the Please check the authentication information message is dis played Check the user name Check the password The mail reception failed without error message Check the receiver s mail address Check that your e mail is not classified as spam on the receiver s mail setting The remote control Check the batteries in the remote control does not work properly Check the ID setting for the remote control See 3 24 9 System Note If
64. ew the system log list iz Press LOG or click the LOG icon in the system control bar The system log list window is displayed on the main monitor System Log List Admin Login Local 2007 11 06 14 33 11 Admin Logout Local 2007 11 05 14 38 59 Admin Login Local 2007 11 06 14 30 05 04 Admin Logout Remote 2007 11 06 14 28 58 Admin Login Remote 2007 11 06 14 77 43 Admin Logout Remote 2007 11 06 14 24 42 Admin Login Remote 2007 11 06 14 18 35 Admin Logout Local 2007 11 06 14 15 57 Admin Login Local 2007 11 06 11 27 20 Admin Logout Remote 2007 11 02 16 33 21 001 054 LOG Bsc Figure 3 13 System log window 2 Use lt P to see the previous or next log list 3 Press LOG or click the Exit LOG button to exit the window e The system log list No Log Message No Log Message 6 Advanced User Login Remote 29 HDD Added HDD4 8 Normal User Login Remote 31 HDD Removed HDD2 9 Normal User Logout Remote 32 HDD Removed HDD3 _ HDD Removed HDD4 HDD Formatted HDD2 HDD Changed HDD3 HDD Damaged HDD3 HDD Damaged HDD4 Table 3 6 System log list FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 33 3 18 Configuration Menu The features and options of the DVR are configured through the menu The operations of this unit can be set via a menu displayed on the main monitor You can sele
65. g is possible for normal partition of HDD when the normal partition of HDD has fully recorded Event partition Overwrite recording is possible for event partition of HDD when the event partition of HDD has fully recorded Off Do not use overwriting Disk full warning When the HDD has overflowed a warning message is displayed Event partition Set the space of event partition for event recording Auto delete Set the auto delete date Off 1 day 2 days 5 days 10 days 20 days 30 days 40 days 50 days or 60 days If you set the auto delete date the recorded data will be deleted except the data within the selected date period of time The Auto delete function is activated every 35 minutes Format Initializes the HDD Hard Disk Drive All data on the selected HDD will be erased Bosch Security Systems Notes If you change the value of event partition the current recorded data of HDD is deleted and the partition is reset The partitions will be formatted automatically and the system will be restarted User Manual FO1U 1 0 2007 12 66 en Connections and settings Digital Video Recorder 3 24 8 Backup Unsdate Configuration Hoard cigk Schedule Syatem Figure 3 52 Backup setup menu FO1U 1 0 2007 12 Partition selection Select a backup partition Schedule You can set the backup schedule Off All options are disabled Instant The backup data is saved manually Weekly or
66. he mouse 2 Select User Log on 3 Enter the user ID and enter the password ADMINISTRATOR Operates the unit without limitations Advanced User Uses the live and search mode functions Normal User Shows the live image only Remote log on Figure 6 4 Remote log on window 4 Select OK and the Divar MR Control Center main window is activated If someone is logged on to the DVR using the Admin ID you can not log on using the Admin ID o If you want to log off right click the mouse on the site name and select User log off e Up to 5 users can connect to the DVR system using the Control Center program as shown below Bosch Security Systems User Manual FO1U 1 0 2007 12 84 en Control Center Digital Video Recorder 6 4 Main screen of DVR Control Center Program Figure 6 5 Main screen of DVR Control Center Program 1 Program Menu e File Exit Exit the program e View OSD gt Channel Number Displays or removes the channel number in the channel window gt Site Name Displays or removes the site name in the channel window gt Camera Name Displays or removes the camera name in the channel window gt Playback Time Displays or removes the date time of playback data in the channel window gt Select All Displays all OSD options in the channel window Sequence Dwell Time Select the sequence to 5 seconds 10 seconds 15 seconds or 20 seconds Video Size Select the video size from 100 150
67. icture This unit is equipped with 4 search functions 5 2 1 Select source device This item is used to set the playback or search device 1 Press SEARCH button the search menu is displayed 2 Press ESC to move to the Title menu tab Bosch Security Systems User Manual FO1U 1 0 2007 12 74 5 2 2 en Search and playback Digital Video Recorder INTERNAL HDO N o N peeeeeee ee ee ee Figure 5 2 Search menu tab 3 Use lt gt to select INTERNAL HDD then press ENTER Figure 5 3 Source device select menu 4 Use lt P gt to select the desired source device e INTERNAL HDD Plays back or searches recorded contents of the internal HDD device e Source device Plays back or searches backup contents of the source device 5 Press ENTER to confirm your selection Notes e While the backup is in progress you can not search the data on the backup device e Do not remove the external USB device while the backup search is in progress from the USB device It may cause a malfunction Date time search Use to search recorded pictures by specifying date hour and minute FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Search and playback en 75 INTERNAL HOO Figure 5 4 Date time search menu Select the Date time search menu Use A 4 P to select the year month date hour or minute column then press ENTER Use lt gt to input the date or time Press ENTER to
68. inal You must set the configuration between the PTZ camera and the DVR I Z FO1U 1 0 2007 12 Select the PTZ camera channel on monitor A you want to control Press PTZ or click the PTZ icon in the system control bar PTZ virtual remote control is displayed on monitor A Use each item to control the PTZ camera User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 29 i wfo ye ye N N lo lal eN t o o ia 4 io pry h s Confirm the preset position Adjust the camera zoom ar mg Manually adjust the focus of a camera oO Manually adjust the iris of a camera Displays the Selected Preset Number Input the preset number Table 3 5 The PTZ virtual remote control button function table Bosch Security Systems User Manual FO1U 1 0 2007 12 30 en Connections and settings Digital Video Recorder 3 15 1 3 15 2 3 15 3 3 15 4 Preset settings Preset position is the function to program camera monitoring positions preset positions associated with position numbers By entering the position numbers you can move cameras to the preset positions Note To activate this function you need to register the preset positions of the PTZ camera To program preset positions dhs Move the camera to a point you wish by using the A W lt 4 gt Press SET or click the SET icon 2 3 Select the preset number you wish
69. ital Video Recorder Input recording settings 1 Click the Input Rec button The instant recording setting window appears Gi ss i EE DR RRR Figure 6 29 The Input recording setting window 2 Set each option using the mouse see 3 19 6 Input recording 3 Click the OK button to confirm the settings Motion recording settings 1 Click the Motion Rec button The instant recording setting window appears w x a Ba ba w k Figure 6 30 The Motion recording setting window 2 Set each option using the mouse see 3 19 7 Motion recording 3 Click the OK button to confirm the settings FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 99 6 7 2 Display settings Display Figure 6 31 The Display setting window 1 Set the OSD options 2 Set the monitor A option 3 Set the monitor B options Schedule setup S i Figure 6 32 The Schedule setup window L Select a day of the week a Mark up the desired recording option e No record Do not schedule recording e Continuous Recording starts automatically at the preset time e Input Recording starts automatically when an input is activated within a designated time e Motion Recording starts automatically when motion is detected within a designated time e Input Motion Recording starts automatically whe
70. itive printed circuit boards Fuse rating For security protection of the device the branch circuit protection must be secured with a maximum fuse rating of 16A This must be in accordance with NEC800 CEC Section 60 Grounding and polarization This unit may be equipped with a polarized alternating current line plug a plug with one blade wider than the other blade This safety feature allows the plug to fit into the power outlet in only one way If unable to insert the plug fully into the outlet contact a locally certified electrician to replace the obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 pole grounding plug a plug with a third pin for earth grounding This safety feature allows the plug to fit into a grounded power outlet only If unable to insert the plug into the outlet contact a locally certified electrician to replace the obsolete outlet Do not defeat the safety purpose of the grounding plug Bosch Security Systems User Manual FO1U 1 0 2007 12 6 en Safety Digital Video Recorder Moving Disconnect the power before moving the unit Move the unit with care Excessive force or shock may damage the unit and the hard disk drives Outdoor signals The installation for outdoor signals especially regarding clearance from power and lightning conductors and transient protection must be in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Se
71. k This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in serious bodily injury or death CAUTION Medium risk Indicates a potentially hazardous situation If not avoided this may result in minor or moderate injury Alerts the user to important instructions accompanying the unit CAUTION Low risk without safety alert symbol Indicates a potentially hazardous situation if not avoided this may result in property damage or risk of damage to the unit NOTICE This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property Important Notices Accessories Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury and or serious damage to the unit Use only with the cart stand tripod bracket or table specified by the manufacturer When a cart is used use caution and care when moving the cart apparatus combination to avoid injury from tip over Quick stops excessive force or uneven surfaces may cause the cart unit combination to overturn Mount the unit per the manufac turer s instructions FO1U 1 0 2007 12 User Manual Bosch Securit
72. l Bosch Security Systems Digital Video Recorder Control Center en 87 6 5 2 Using the live window Playback of Recorded Data o ooo ee ececccr eo em Ol tos ov m 0 OF OS a Ic 11 i 13 mts 1a 1 aa ol 2 Ze oe Cea Pee A nE i ooo COTIT T ecco c cece ey q SSlCevreratiin Ty ass 5 bal Ii E Th ee eet oe on Figure 6 9 Camera View window L Select the camera s display window 2 Select the date The day is displayed in a blue text when recorded data exists 3 Select playback start time When using timeline to search a start time use the zoom in out icons for more detailed searches 4 step 4 Select playback speed and mute speaker icon Start playback using these control buttons Notes e If you don t want to play with sound click the speaker icon to mute e You can not use the playback function when you log in with the Normal User ID 6 5 3 Using the Pan Tilt Zoom function You can control the PTZ cameras via the network Figure 6 10 The Pan Tilt Zoom window Bosch Security Systems User Manual FO1U 1 0 2007 12 88 en Control Center Select the PTZ camera channel window in the camera view mode Select Pan Tilt Zoom tab Use virtual remote control buttons to control the PTZ camera O Digital Video Recorder To confirm the preset position and set a menu option in the PTZ camera To manually adjust the focus of a camera FOCUS To adjust the camera zoom ZOOM IR
73. l addresses E mail test Select E mail test to test sending an e mail Note The SMTP server SMTP port no user name or password settings are optional The DVR can send e mail directly without the use of an SMTP server or MTA message transfer agent In certain cases all e mail should be forwarded to a specific SMTP server Specify the server host name or IP address in such a case For more detail on SMTP setup ask your network administrator and or mail service provider Bosch Security Systems User Manual FO1U 1 0 2007 12 58 en Connections and settings Digital Video Recorder 3 23 5 Emergency Aotitication Mail Figure 3 44 Emergency setup menu Notification On Notifies the Alarm notifier program about unit operating information according to your notification settings Off Notification function is not used IP address Port no Enter the IP address port number of the Alarm notifier program using the virtual keyboard The factory default port for this function is 9002 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1025 65535 You can set up to 9 IP address port numbers FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 59 3 24 System settings 3 24 1 Date Time NTP Bee per User Update Configuration Hard diak Date format Timea format Time
74. list If you want to cancel the registered exception day select the exception day in the list and click the delete button FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 101 6 7 3 6 7 4 Event setup RHEGEOCRSRARREEREE Be Figure 6 35 The Event setup window 1 Set the event options e Input Displays the number of the ALARM I O port e Input type The alarm state can be set to either N O Normally Open or N C Normally Closed e Linked camera Select the connected camera channel with the ALARM I O port e Relay out Select the alarm output number of the RELAY OUT terminal for the output alarm signal 2 Setting Alarm ackn options e Alarm ackn Set the Manual or Post event time option to off Network setup Port giz Goi SO ao fos BOOS Goi Son Figure 6 36 The Network setup window TCP IP settings The DHCP IP address Subnet mask Gateway Primary DNS Secondary DNS and Remote client port no option settings are not available in the client program You can set these options in the system menu of the DVR Bosch Security Systems User Manual FO1U 1 0 2007 12 102 en Control Center Digital Video Recorder HTTP port no Enter the HTTP port number Bandwidth limit Enter the bandwidth to adjust the data traffic Mail settings Set the mail options Notification When you mark up the notification option no
75. ms This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualty hazards as outlined in UL s Standard s for Safety for Information Technology Equipment UL 60950 1 UL Certification does not cover the performance or reliability of the security or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Copyright This user guide is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Safety en T Trademarks All hardware and software product names used in this document are likely to be registered trade marks and must be treated accordingly NOTICE This operation manual has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for damage resulting directly
76. n input and motion detection occur within a designated time Select the channel to set the schedule Click the start time cell block and drag amp drop to select a time period cell block or Click the start time cell block of a channel and drag amp drop across the channels to select the time period block for multi channel setting at the same time The color of the cell blocks will change Bosch Security Systems User Manual FO1U 1 0 2007 12 100 en Control Center Digital Video Recorder Schedule Copy settings Figure 6 33 The Schedule copy setting window ile Select the source day to copy 2 Select the destination day from the day of the week weekday or weekend options 3 Click the copy button to copy the schedule data Exception day settings a eaaa Figure 6 34 The Exception day setting window I Mark up the exception day option Select the date to set the exception day schedule Mark up the desired recording option Select the channel to set the schedule woo p w Click the start time cell block and drag amp drop to select a time period cell block or Click the start time cell block of a channel and drag amp drop across the channels to select the time period block for multi channel setting at the same time The color of the cell block will change 6 Enter the name of the exception day Click the add button to add the special day settings The exception day is added to the
77. nd level 3rd level DVR 16L DVR BL Default Ch iame Camera 1 Camera 1 Camera Camera 16 Camera 8 Covert Off es Audio 01 08 None 01 04 None Yes nN Covert Y Audio O41 08 None 01 04 None _ Channel OtName Yes Camera Name me Control ID OO Yes Yes PTZtet o d A a S Continuous Rec camara 30 IPS NTSC 25 IPS PAL Yes o PEPES 352X240 NTSC 352X288 PAL Yes ee ee eee Yes eRe Yes a a shotion tex Yes PAL to EMEA APR NTSC to US p n sm Continuous Yes Mon Continuous Yes te Continuous Ves Wed Continuous Yes Schedule oth TT Continuous Ves oo o Continuous Yes Oo Sa o Continuous es Exceptiondays Continuous Yes Bosch Security Systems User Manual FO1U 1 0 2007 12 122 en Reference Digital Video Recorder Classification Detailed Items Default Setting Factory Language OSD Camera name sisplay Camera status Monitor A Seq dwell time Seq dwell time Monitor B a Event popup Off O Input type Camera Relay output Camera Sensitivity Relay output Area Alarm ackn DHCP IP address Subnet mask Gateway Primary DNS Secondary DNS Remote client port Input N JAN N IAN JA N N JAN IHN W N JIN V NININININ IN 01 16 01 08 None Event O01 Name Motion None O Alarm ackn Post event time O NULL NULL NULL NULL TCP IP NULL 9001 HTTP port no Bandwidth limit User name Password
78. nds an e mail when the administrator password has changed DDNS FO1U 1 0 2007 12 User ID Enter the DDNS registered user name Password Enter the user password in User ID Note The DDNS function is serviced using a TCP 8245 port by No IP http www no ip com In case the DVR is used in the network system with a firewall open the TCP 8245 port so that DDNS data can get into firewall For more detail on firewall setup ask your network administrator and or network service provider User Manual Bosch Security Systems Digital Video Recorder Control Center en 103 Emergency Notification Notify the Alarm Notifier about unit operating information according to your notification settings IP Address Port Enter the IP Address and port number of the Alarm Notifier program installed on the PC The factory default port for this function is 9002 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1025 65535 You can set up to 9 IP address and port numbers 6 7 5 System setup m rerai TH ET Figure 6 37 The System setup window Date Time settings Set the date time options e NTP Mark up when using the NTP Network Time Protocol server for time adjustment Date format Select the date display format o Time zone This option setting is not available in the Control Center program e Server Select your time ser
79. nected to this unit U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides informa tion regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode NOTICE This device is intended for use in public areas only U S federal law strictly prohibits surreptitious recording of oral communications components that can be recycled and reused This symbol means that electronic and electrical appli ances which have reached the end of their working life must be collected and disposed of sepa rately from household waste material Separate collecting systems are usually in place for disused electronic and electrical products Please dispose of these units at an environmentally compatible recycling facility per European Directive 2002 96 EC Environmental statement Bosch has a strong commitment towards the environment This unit has been designed to respect the environment as much as possible Electrostatic sensitive device Use proper CMOS MOS FET handling precautions to avoid electro Static discharge 7 Disposal Your Bosch product was developed and manufactured with high quality material and NOTE Wear required grounded wrist straps and observe proper ESD safety precautions when han dling the electrostatic sens
80. nnections with the Control Center programs or web browser will be disconnected FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 55 3 23 2 DDNS Dynamic Domain Name System Protification Mail Emergency Pasewerd Figure 3 41 DDNS setup menu User name Enter the DDNS registered user name using the virtual keyboard Password Enter the user password in User name using the virtual keyboard Note The DDNS function is serviced using a TCP 8245 port by No IP http www no ip com In case the DVR is used in the network system with a firewall open the TCP 8245 port so that DDNS data can get into firewall For more detail on firewall setup ask your network administrator and or network service provider Bosch Security Systems User Manual FO1U 1 0 2007 12 56 en Connections and settings Digital Video Recorder 3 23 3 Notification Mail Emergency Motion detect Drak full Admin PW changed Wideo loss Power on ctf Figure 3 42 Notification setup menu Alarm on On Sends an e mail when an input has been activated Off Not used Motion detect On Sends an e mail when motion detection has been activated Off Not used Disk full On Sends an e mail when the HDD has fully recorded Off Not used Admin PW changed On Sends an e mail when the administrator password has changed Off Not used
81. ntinuously or triggered by events input and motion detection The recording schedule screen displays one day of the week showing the schedule of all channels over a 24 hour period For each 1 hour cell block the recording method can be specified The recording method for each block is shown in color for easy viewing Schedule _ I Mowe Ente ETT Te EJ Exit Schedule Sun aes I cH mk mo Exception days S00 4 ou me od a Figure 3 23 Schedule setup menu To set the Recording Schedule for a typical day of the week 1 Select a day of the week Sun Mon Tue Wed Thu Fri or Sat 2 Select the desired channel to schedule recording 3 Select the time cell block for the start time Schedule Sun te la led oe cs Mowe Ente fal E3 Prev T a 5 E i 5 Figure 3 24 Schedule setup menu Bosch Security Systems User Manual FO1U 1 0 2007 12 4 Press ENTER or click the left mouse button to select a recording mode The color of the cell blocks will change automatically Gray No scheduled recording Green Continuous recording Recording starts automatically from the preset time Red Input event recording Recording starts automatically when the input is activated within a designated time Blue Motion event recording Recording starts automatically when motion is detected within a designated time Yellow Input Motion recording Recording starts automatically wh
82. o C KT i esee N aeeoe N aeoe la Du PH AT E ofe RS 422 485 KBD IN COM1 ETHERNET MONB MONA VGA USB Ho DW HHA E 100 240V 50 60Hz Load HO E gt EJOO ep miili RS 422 485 KBD IN COM1 ETHERNET MONB MONA VGA USB a E HH Be E Figure 2 3 Back panel VIDEO INPUT Connect the camera s video output to these BNC connectors LOOP OUT The signal from VIDEO INPUT connector is looped out to this connector Power Cord Inlet AC IN Connect the power plug 4 AUDIO OUT Connect the audio input signal of an external device BIPHASE Connect a pan tilt zoom control unit via the supplied 15 pole D type connector board 6 AUDIO IN Connect the audio output of an external device ALARM I O Connect up to 16 alarm inputs via the supplied 25 pin D type connector board Connect up to 8 alarm output relays via the supplied 25 pin D type connector board EJ RS 422 485 Terminals Connect RS422 485 compatible cameras 9 KBD IN Connect a Bosch CCTV keyboard unit to the KBD IN socket COM1 Use to connect to a host device equipped with RS 232C connector such as a personal computer ETHERNET Port Connect the ethernet 10 100Mbps network cable for controlling this unit via a PC network MON B BNC Type Connector Connect to spot monitor or display device Bosch Security Systems User Manual FO1U 1 0 2007 12 14 en Introduction 2 5 Digital Video Recorder MON
83. on the monitor A Screen mode e Full Screen Mode When you see the selected channel on the full screen e 4 6 8 9 and 16 view Mode Displays selected multi screens on the monitor A EJ Selected view mode Sequence Views the all channels in sequence 3 Select OK A and press ENTER to confirm your selection Note To display the screen you desire to watch in full screen mode double click the desired channel Bosch Security Systems User Manual FO1U 1 0 2007 12 28 en Connections and settings Digital Video Recorder 3 14 2 Monitor B You can select the live screen mode to full or 4 view screens on the monitor B Press B B button or click the icon in the system control bar The screen mode select menu of monitor B is displayed on the monitor A Select screen mode D O 0 0 0 Ei i e Pe 2 2 x ESC REIH Figure 3 10 The screen mode select menu of monitor B Selected channel of the monitor B Channel buttons Press a 1 to 16 channel button to see the current camera image on the monitor B Screen mode e Full Screen Mode When you see the selected channel on the full screen e 4view Mode Displays 4 view screens on the monitor B EJ Selected view mode Sequence View all channels in sequence Select OK B and press ENTER to confirm your selection 3 15 PTZ camera control You can control the cameras connected via the biphase port and data port RS 422 485 term
84. or 38400 Set the motion options Sensitivity Set the sensitivity level for the created motion detection area Sensitivity can be set from O0 to 10 Relay output Select the number of the ALARM I O port for the output alarm signal when motion is detected Area Select the desired motion detection area on the preview window screen using the mouse Click the one point and drag amp drop the end point to select the motion area Notes e If you want to display the grid mark up the Show grid option e If you want to select the entire area click the Set all button or click the Clear all button to cancel the selected area User Manual Bosch Security Systems Digital Video Recorder Control Center en 97 Continuous recording settings 1 Click the Continuous Rec button The continuous recording setting window appears Figure 6 27 The Continuous recording setting window 2 Set each option using the mouse see 3 19 4 Continuous recording 3 Click the OK button to confirm the settings Instant recording settings 1 Click the Instant Rec button The instant recording setting window appears BREE BEESHOSRSRa a a M w e w Figure 6 28 The Instant recording setting window a Set each option using the mouse see 3 19 5 Instant recording 3 Click the OK button to confirm the settings Bosch Security Systems User Manual FO1U 1 0 2007 12 98 en Control Center Dig
85. or indirectly from faults incompleteness or discrepancies between the user guide and the product described More information For additional information please contact the Bosch Security Systems location nearest you or visit our web site at www boschsecurity com Bosch Security Systems User Manual FO1U 1 0 2007 12 8 en Safety Digital Video Recorder FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Introduction en 9 2 Introduction 2 1 Features Stable embedded Linux operating system Small file sizes with MPEG 4 compression Internal storage capacity to 2TB NTSC and PAL selectable video format Full realtime recording Up to 480IPS 352 X 240 DVR 16K DVR 16L NTSC Up to 400IPS 352 X 288 DVR 16K DVR 16L PAL Up to 240IPS 352 X 240 DVR 8K DVR 8L NTSC Up to 200IPS 352 X 288 DVR 8K DVR 8L PAL Various recording resolutions and quality levels ACIF 704x480 2CIF 704x240 CIF 352x240 NTSC ACIF 704x576 2CIF 704x288 CIF 352x288 PAL 5 step quality level Lowest Low Normal High Best Easy operation using various user interface amp user friendly GUI Optical mouse Full function IR remote controller Jog Shuttle Powerful multiplex functions Simultaneous live display recording playback network transmission back up Various search functions Date time search event search bookmark search smart search Event data protection by event partition recording
86. p through output is connected to an additional device the device s termination is set to 75 ohms and the monitor s termination is set to high impedance note that this is not necessary on devices with automatic termination Connecting the RS 232C COM 1 Port The serial RS232 console port connector is used to connect a PC to the unit for service purposes Use a null modem cable to connect the serial port of the PC to the unit This terminal is compliant with the RS 232C standard FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 19 3 5 3 6 3 6 1 3 6 2 3 6 3 3 7 3 7 1 3 7 2 3 7 3 CCTV keyboard connections The keyboard input connector is used to connect an external CCTV keyboard to the unit Connect the keyboard to the KBD IN connector For short distances up to 30m standard 6 core telecom flat cable can be used to supply power and signal connections for the keyboard For distances over 30m between keyboard and Divar MR the Keyboard Extension Kit LTC 8557 must be used This kit provides junction boxes cables and the appropriate power supply for the external keyboards The recommended cable type is Belden 9841 or equivalent Network connection LAN connection Connect the LAN port to an available 10 100 base T port with a straight ethernet cable not supplied Automatic network configuration The DVR can automatically obtain and configure th
87. pport either PAL or NTSC Depending on the camera s video format the video process can differ greatly therefore it can be difficult to recognize the video data if the video format setting is different from the camera s video format There is a lot of Check if the video signal output from the camera has a problem Ensure screen noise the camera is not damaged by trying another camera with a working accompanying the video output image Check if the video cable connection between the camera and the DVR is cut crosswired or shorted Check if there is a high voltage wire around the video cable connection between camera and DVR system It can cause interference and affect video quality Check that the video cable connection between the camera and the DVR system is the correct video cable When a normal power supplying cable is used instead of the video cable screen noise can be generated Check that the type of input in the camera setting is the same as with the connected input The connected input is not operating Check that the system is set to use the input in the recording schedule window in the recording setting menu Check that the input is properly connected to the ALARM I O Check that the system is set to use the PTZ camera in the camera setting menu The connected PTZ camera is not operating Check that the power cable of the PTZ camera is properly connected Check that the signal cable of the PTZ cam
88. ption days setup menu 3 Press the SET button or click the EI an icon on the exception days setting menu The specific date selection menu appears Bosch Security Systems User Manual FO1U 1 0 2007 12 46 en Connections and settings Digital Video Recorder schedule Exception days mg Fp E Minve Edit tat Prev z E E E F E E i e MC EBeeeeeeaee Lay copy Ch copy Exit Figure 3 29 Exception days setup menu 4 Enter the necessary information for year month and date lt gt A V Press to move the columns OK or Cancel buttons e lt gt or left right mouse button Changes the value at the current position 5 Use lt 4 gt A F to select OK button and press ENTER The virtual keyboard menu appears schedule Exception days re ar a Flew enter the aame of the aveptos day ors aes eb es ee E ATeCrPrEFGA TT k E MnO Pore Tv wey eS T E E 3 F 5 E Figure 3 30 Exception days setup menu 6 Enter the name of the exception day Use A 4 P gt to select a character then press ENTER to confirm your selection T Use A F to select the OK icon then press ENTER to fix the date of the special day and return to the special day menu screen 8 Select the schedule time and set the recording method for each channel FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder 3 20 3 3 20 4 Bosch Security Systems Use
89. r Manual Connections and settings en 47 Checking the Exception days schedule list Press INFO when the Exception days option is selected The exception days scheduled list appears i Schedule Exception days co i A if reer er Wn ya Tz D i i a es d Tog iiw Liri O Adi CEJ Oclete GA Et Day copi 7 a Ch oopy a Me Cant inp hi 1 Exit Fi ee a Pie ore Figure 3 31 Exception days scheduled list Select a exception day title on the list and press ENTER The title color turns orange Select the Edit icon press ENTER to edit the exception day or press CLEAR to delete the exception day schedule Press ESC to exit the exception day schedule list Note If the exception day recording schedule is duplicated with the other recordings only the exception day recording is possible Copying the recording schedule Copying from the scheduled data of the channel You can copy the schedule data of the channel to the other channel s within the selected day of the week Select the day of the week and press ENTER Select channel that you want to copy Press COPY then the channel selection menu appears FO1U 1 0 2007 12 48 en Connections and settings Digital Video Recorder 1 F 3 E q 7 g 5 10 DI T de Da hd Figure 3 32 Channel copy menu 4 Use lt gt to move to the left or right column then press ENTER to select the target channel s Yo
90. rd setting menu Check the HDD detection status in the System Information window If the HDD detection status is abnormal check the HDD formatting Check the recordable disk space in the HDD Check the overwrite option in the setup menu for overwrite recording Check if there is recorded video data for the time that you are trying to search on the table If there is no recorded video data check the recording mode in the record setting menu Check the HDD detection status in the system information window If the HDD detection status is abnormal check the HDD formatting Check the user type The search function is not available for a normal user User Manual FO1U 1 0 2007 12 116 en Reference Digital Video Recorder Symptoms Resolutions Audio data recorded with video data is not playing Check that the audio recording option is correctly set for the camera you wish to record audio Check that the speaker and audio line input on the rear of system are connected correctly Check that the connected speaker is working properly The colors of some If the camera connected to the system has a problem check that the camera videos are camera is not damaged by connecting another camera into a working strange or videos are video output displayed abnormally a Check video format setting of the unit is the same as the connected camera s video format Depending on your region the camera s video format can su
91. s unit Instant Backup Connect the backup USB device or insert a recordable disk to the disc driver for backup Select the partition you want to backup Select INSTANT from the schedule options Select the backup device Select the Time range date Time range start time and Time range end time for backup Select the Estimate size icon and press ENTER 2 ee Se YS Check the size of the selected data and free space If the device does not have enough space create space on the device or erase the previously stored data Select the Start backup icon and press ENTER to start backup Exit the setup menu You can check the backup status on the system control bar in backup progress gt haa Note You cannot stop the backup while in progress The warning message will appear for the conditions listed below When the start time and end time are the same value When the start time is later than the end time A media does not have enough space When you set the time for data that does not exist The disc burning is carried out by a single session closed format If you use the CD DVD writer device for backup the backup status will be displayed as shown below Bosch Security Systems User Manual FO1U 1 0 2007 12 68 en Connections and settings Digital Video Recorder Ist Status of making ISO image 2nd Status of writing E mN F EE sl LEE Back isin progress Daily Weekly ba
92. t direction Bosch Security Systems User Manual FO1U 1 0 2007 12 38 en Connections and settings 3 19 4 Continuous recording Settings concerning continues recording Camera J Camera ase Mowe Vielen adj Select PTZ E3 Exit Camera Continuous Ree j imstant Aes ie T ee a _ input Ree Motion Raz th Aendinien Quality Frame rain Vides format si M PS a TT AE TT es ETT Figure 3 18 Continuous recording setup menu Ch Displays the channel number Resolution Selects the recording resolution Digital Video Recorder Quality Selects the recording picture quality Lowest Low Normal High or Best Frame rate Selects the frame rate The frame rate is the number of recorded frames per second According to resolution the frame rate is set automatically If you wish to set manually refer to the below table 352 240 1 3 5 1 0 15 20 30 NTSC Table 3 7 Frame rate table FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 39 3 19 5 Instant recording Settings concerning instant recording Camera oa Camera Mowe Video adj Select PT FES Exit Cartinuouws Aag Camera Instant Age _ my i ge se input Ree Motion Rac th Anemie Quality Frama mir Video format 2 J E a ee l Norm 2 IFS Figure 3 19 Instant recording setup menu Ch Displays the
93. t menu appears ELAN AL WDD Tims Channel Ewen Tyge Figure 5 7 Event list FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Search and playback en 77 6 Select the recording data on the event list then press lt P click Play gt or double click the selected data to start playback The picture is displayed on the monitor A Press STOP W to stop playback and return to the event list menu 8 Press ESC repeatedly to exit the event search menu 5 2 4 Smart Search Pictures recorded via motion detection can be searched by specifying the motion detection conditions UCTE i stefTime CLhgrinel Start Tens ini Timer aemm Ara Figure 5 8 Smart search menu ie Select the Smart search menu 2 Set the channel number start time end time and sensitivity options lt gt A F Moves to the options or sets the selected option ENTER Selects option or confirms the setting Note The time between the start time and the end time is automatically set at 1hour 3 Select the Set in the Area option then press ENTER The picture from the selected camera is displayed 4 Set the motion mask setting The area switches between active and inactive each time you press ENTER Click the one point and drag amp drop the end point to the right to select the motion using the mouse Click the one point and drag amp drop the end point to the left to unselect the mo
94. t output connection board supplied with the unit simplifies all alarm connections to the unit Le ee ed eoeoeeeceeeeeee jelelelele O ALARMIO RS 422 485 KBD IN iA Relay 2 iB Relay 3 4A Relay 8 OO 00 00 OO 00 OO OD OO O00 00D Figure 3 4 Alarm I O port connector Connecting the Inputs Each alarm input line can be switched by a relay contact from devices such as pressure pads passive infra red detectors smoke detectors and similar devices Wire them as either N O Normally Open or N C Normally Closed You can configure the alarm inputs as N O or N C in the menu system The default is N O Connecting the Alarm Outputs The eight alarm output relays respond to input alarms and triggers You can configure the alarm outputs as N O or N C in the menu system The relays are active for the duration of the driving event Connect the application to the alarm output relays resistive loads only Do not exceed 1A 30V DC 0 3A 125V AC on an alarm output relay s contacts The contacts must not be used at AC line voltages ALARM I O 25 pole D type socket Alarm_in_10 10 Alarm input 10 FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 23 2 2 2 Table 3 3 Alarm I O pin configuration Relay1 A 1 1 1 1 1 1 1 1 2 2 2 2 2 3 11 System operation Default monitor setting is VGA L Turn on the unit System
95. the system setup ahs Select the desired channel for instant recording 2 Press the REC button on the remote control or press button on the front panel to start record The red dot is blinking on the selected channel screen of the main monitor sony NU each G lt a e MARK PAUSE STOP Lv J Le lt dil gt i a fa Cf REC Figure 4 1 Rec buttons 3 Press the REC button on the remote control or press button on the front panel to stop recording If you stop instant recording the recording mode will be changed into the scheduled recording mode and the red dot disappears Figure 4 2 Selected channel screen of the main monitor showing the red dot Bosch Security Systems User Manual FO1U 1 0 2007 12 72 en Recording FO1U 1 0 2007 12 Digital Video Recorder Notes e You can not record the Instant and Continuous recording under the fol lowing conditions A HDD is not formatted The channel has no video input for display Overwrite is set to Off or Event Partition and normal partition is full On the HDD setting the event partition is set to 100 e You can not record the Input and Motion recording under the following conditions AHDD is not formatted The channel has no video input for display Overwrite is set to Off or Normal Partition and event partition is full On the HDD setting the event partition is set to 0 Th
96. the DVR Bosch Security Systems User Manual FO1U 1 0 2007 12 64 en Connections and settings Digital Video Recorder 3 24 6 Configuration Update Hart oiak Expat configuration Backup Factory defaults s System Figure 3 50 Configuration setup menu Import configuration Import the DVRs configuration data from the USB memory stick Export configuration Export the configuration data from this DVR to the USB memory stick Factory defaults You can reset the DVR to its original factory settings Some options cannot be reset Video format Date Time Time zone Daylight saving Daylight saving start Daylight saving end User settings Event partition settings Notes e Configuration data import is available when the configuration data of a DVR is the same kind as this unit s data e If you use a USB memory stick for configuration export you must dis connect the other external USB devices FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder 3 24 7 Hard disk Disk full warming Evont partition Auto celete Format Connections and settings en 65 a hdove Enter eters ETF Exit a Update E Fa Configuration es Backup oyatem i igs Figure 3 51 Hard disk setup menu Overwrite All Overwrite recording is possible when the normal partition and event partition of HDD have fully recorded Normal partition Overwrite recordin
97. the DVR for the first time the Security Warning window is displayed You must click Install on the Security Warning window to install the program for using the Web Viewer If you click Don t Install the Web Viewer program is not available Bosch Security Systems User Manual FO1U 1 0 2007 12 112 en Additional programs Digital Video Recorder 7 4 2 Using the Web Viewer You can control the live image using the Web Viewer Figure 7 11 The Web Viewer window Mode select icon Click to change the PTZ View mode Ee or Live View mode _ m a _ os a a a Live screen display window 7 4 3 Live screen control Left mouse button Select the channel If you want to set to full screen double click the selected channel To return to the previous screen double click again Right mouse button If you want to exit full screen mode right click the mouse to return to the normal screen FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Additional programs en 113 7 4 4 PTZ View control Click the e icon to change the PTZ view mode The PTZ virtual remote control is displayed Figure 7 12 The PTZ virtual remote control window Use virtual remote control buttons to control the PTZ camera For more details refer to 6 5 3 Using the Pan Tilt Zoom function Bosch Security Systems User Manual FO1U 1 0 2007 12 114 en Additional programs Digital Video Re
98. the Setup menu If the actual recorded data size is larger than the estimated recording data size the schedule backup may not be activated User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 69 3 24 9 System Date Time MTP Bee per User Undate Configuration Hard disk DVA IO E edit Backup Auto user logout Figure 3 53 System setup menu IR remote controller Select the IR remote ID for this unit 01 09 If you use multi systems set the IR remote ID for each DVR unit DVR ID Select the DVR ID for this unit 01 16 If you use multi systems set the DVR ID for each DVR unit Auto user logout Logout is automatical at fixed intervals You can set auto logout time to 5 min 10 min 30 min 60 min or Off Bosch Security Systems User Manual FO1U 1 0 2007 12 70 en Connections and settings Digital Video Recorder FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Recording en 71 4 Recording Images from a camera will be recorded on the built in hard disk Note External recording devices can be used as copy areas for images recorded on the hard disk It is impossible to record images on the external recording devices directly 4 1 Instant Recording Ensure all the cameras are connected and that time and date have been set correctly Before you start recording first SETUP the recording settings in the instant recording menu of
99. this key again to return from full screen to multiscreen COPY Copies the recorded data to an external device SEARCH Displays the search menu o MARK Sets the mark point for recording search You can set the mark point during the single channel playback of recorded data PAUSE ll Pauses playback e STOP W Stops playback o REC Starts or stops recording lt lt ll Reverse search Searches the recorded images in reverse sequence lt gt Playback or reverse playback of recorded images gt gt II Forward search Searches the recorded images in forward sequence Number Buttons 0 1 9 To select the PTZ preset number ID or channel INFO Displays or removes the system information window LOG Displays or removes the System Log List window PTZ Switches this unit to PTZ mode to control the connected PTZ camera TOUR Tours all registered preset positions in the PTZ camera ZOOM Adjusts the zoom level of the PTZ camera FOCUS Adjusts the focus of the PTZ camera IRIS Adjusts the iris of the PTZ camera PRESET SET Registers the PTZ camera s preset positions CLEAR Deletes a memorized preset position MOVE Moves the camera to the preset position ID Set the appropriate DVR system ID to operate via the IR Remote Controller when using multiple DVRs Press the ID button then press the number button within 2 seconds to select the syst
100. tify the user about unit operating information by e mail according to your notification settings TLS Mark up when using the TLS Transport Layer Security function SMTP server Enter the SMTP server address SMTP port no Enter the SMTP port number Typically the TCP port used for SMTP is 25 However in some cases it is better to change this port number for added flexibility or security If desired change the port number 1 65535 User name Enter the user name Password Enter the password Mail address 1 3 Enter the mail address You can input up to 3 e mail addresses Note The SMTP server SMTP port no User name or Password settings are optional The DVR can send e mail directly without the use of an SMTP server or an MTA message transfer agent In certain cases all e mail should be forwarded to a specific SMTP server Specify the server host name or IP address in such cases For more detail on SMTP setup ask your network administrator and or mail service provider Notification Set the notification options Alarm on Sends an e mail when an input has been activated Video loss Sends an e mail when a video signal from the camera has stopped because of a cable disconnection or malfunction of a camera Motion detect Sends an e mail when motion detection has occurred Power on off Sends an e mail when power is on or off Disk full Sends an e mail when the HDD has fully recorded Admin PW changed Se
101. tion _ 1 3 5 1 0 15 20 30 NTSC 704 240 1 3 0y 10 LD pom rem shes Table 3 10 Frame rate table Pre event Specify the pre event recording time that records the situation until motion has been detected Off 5 10 20 30 40 50 sec or 1 min Post event Specify the post event recording time that records the situation after motion has been detected 10 20 30 40 50 sec or 1 2 3 5 10 min Note Pre event times given are only a rough guide Actual times are dependent upon resolution quality and frame rate settings as well as the number of channels selected for pre event recording Bosch Security Systems User Manual FO1U 1 0 2007 12 3 19 8 Video format Selects the video format to NTSC or PAL according to your video system format iig Select the video format The confirmation message is displayed 2 Select OK and press ENTER After the HDD has been formatted the system will reboot Camera e Move Who mij Enter Select PT E3 Exit Continuous Ree Camera Video fonmat lretant Aes input Rer Move Ermia Edit Motion Aine Figure 3 22 Video format setup menu FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 43 3 20 3 20 1 Schedule settings The DVR can record according to a schedule set by the user It can also record manually regardless of date and time The recording can be made either co
102. tion You can delete a memorized preset position Ale Click the CLEAR icon 2 Use number icons to enter the memorized preset index number Click the icon The preset position will be deleted To tour the preset positions You can tour all preset positions 1 Click the TOUR icon All registered preset positions in the camera will be selected and the camera position image will be switched on to the active window 2 You can stop the tour by clicking the TOUR icon Setup for PTZ camera You can change the setting of PTZ camera using each item in the menu i Click the SETUP icon SETUP MENU appears in the windows 2 Use the arrow and J icons to set the options Note Refer to the manuals of the PTZ camera for more details Bosch Security Systems User Manual FO1U 1 0 2007 12 90 en Control Center Digital Video Recorder 6 5 4 Using the Log View function You can see the system log list of selected site names in the remote setup tab via the network ie Select the log view tab Log search menu appears Figure 6 11 The log search menu window 2 Click the date icon and select the day for the log search The selectable days are displayed in blue text color l 11 2007 Figure 6 12 The day select window 3 Click the search icon The system log is displayed in the list FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Control Center en 91
103. tion using the mouse The active areas are indicated in red Press ESC to exit the mask setting 6 Select Search then press ENTER The motion detect list menu is displayed Bosch Security Systems User Manual FO1U 1 0 2007 12 78 en Search and playback Digital Video Recorder INTERNAL HOD Chere Sturt Teme gt grr l WEF SCH aT Figure 5 9 Motion detect list 7 Select the recording data on the motion detect list then press lt P click Play gt or double click the selected data to start playback The picture is displayed in the main monitor Press STOP W to the stop playback and return to motion detect list menu Press ESC repeatedly to exit the smart search menu 5 2 5 Bookmark Search Search the desired picture with a bookmark registered by the bookmark function 1 Select Bookmark Search menu INTERNAL HOD Figure 5 10 Bookmark search menu 2 Select the recording data on the list then press lt P click Play gt or double click the selected data to start playback The picture is displayed in the main monitor Press STOP W to stop playback and return to the bookmark list menu Press ESC to exit the bookmark search menu FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Search and playback en 79 Notes e If you want to delete the bookmark on the list press the CLEAR button e Backup data can not be played back by a bookmark search e
104. to register 4 Press ENTER or click the 2 icon The position and its number are memorized 5 Repeat steps 1 4 to add additional positions Note Preset numbers from O to 255 are available on this unit but the actual preset range differs depending on PTZ cameras Changing to a preset position The following function is available only with cameras provided with the preset function The preset function makes the PTZ camera move to the programmed preset position It is necessary to program preset positions for the PTZ camera beforehand 1 Press the MOVE button or click the MOVE icon 2 Use number buttons to enter the memorized preset position s index number then press ENTER or click the a icon The camera moves to the preset position and the picture of the camera in that position appears on the monitor To clear the preset position You can clear a memorized preset position es Press the CLEAR button or Click the CLEAR icon 2 Use number buttons to enter the memorized preset index number then press ENTER or Click the W icon to clear the preset positions Note This function may not be available depending on PTZ cameras FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 31 3 15 5 To tour the preset positions You can tour all preset positions ig Press the TOUR button or Click the TOUR icon All registered preset positions in the camera will be s
105. u can cancel the selected channel by pressing ENTER 5 Use A F to select OK then press ENTER to confirm your selection Copying from the Scheduled Data of the day You can copy the scheduled day of the week to another day of the week weekday and weekend using the MARK button ie Select the day of week that you want to copy 2 Press MARK then the select date s menu appears py be ee ee de a LF E i m i Figure 3 33 Day copy menu 3 Use lt P gt to select the target date s 4 Use A F to select OK then press ENTER to confirm your selection FOLU 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Connections and settings en 49 3 21 Display settings 3 21 1 OSD Monitor A Monitor Camara nams Camara status Figure 3 34 OSD setup menu Language Select a language for the setup menu and information display Camera name On Displays the title of the camera Off Displays the live picture without the title of the camera Camera status On The current camera recording status is displayed Off Remove the current camera recording status Bosch Security Systems User Manual FO1U 1 0 2007 12 50 en Connections and settings Digital Video Recorder 3 21 2 Monitor A TERT Monitor E Figure 3 35 Monitor A setup menu Seq dwell time You can set the camera sequence time to 2 sec 5 sec 10 sec 20 sec 30 sec 40 sec 50 sec 60
106. ver The DVR will obtain the average time among 5 public servers time nist gov time a nist gov time b nist gov ntp nasa gov clock isc org Private time server Enter the private time server s IP address or host name Sync interval You can set synchronized interval with the NTP time server to 1 day 1 hour 1 week and 1 month Daylight saving Mark up when you use the daylight saving function Start Select the Daylight Saving start time End Select the Daylight Saving end time Hard Disk Overwrite Select the overwrite recording type Off Normal partition Event partition or All This function is possible when the selected HDD type has fully recorded o Disk full warning When the HDD has overflowed the warning message is displayed Event partition Sets the space of event partitions for event recording Bosch Security Systems User Manual FO1U 1 0 2007 12 104 en Control Center Digital Video Recorder Log Out Auto user logout Setting the logout time You can set the auto logout time to 5 minutes 10 minutes 30 minutes or 60 minutes Sound settings Select the beeper options Button beeper Makes a sound when using the buttons Input beeper Makes a sound when an input occurs o Motion beeper Makes a sound when motion is detected System beeper Makes a sound when a cooling fan is not activated or the HDD has bad sector Update settings Set the update options o Item Sele
107. vou want to delete the message s Yes flo Figure 7 6 The confirmation window 3 Click Yes to delete the message 7 3 Archive Player program You can playback from the archived data on the PC using this program The Archive Player program is saved automatically when you install the Control center program or archive the data 7 3 1 Main screen of Archive Player ear Me dhie pir Figure 7 7 The Archive Player window e Program Menu File F gt Open Open the archived file gt Print Print image in window of Archive Player FO1U 1 0 2007 12 User Manual Bosch Security Systems Digital Video Recorder Additional programs en 109 gt Exit Exit the program Lang L Select the language for Archive Player program Help H gt About Archive Player Displays Archive Player information Control Icons T Pauses playback Starts playback a Stops playback Watermark Setting Check the option Check watermark If the file which is in playback differs from the file that is originally recorded a warning window will appear Video Information File Name Displays the file name Video Format Displays the video type of the data Time Displays the recorded date and time of data Recording Mode Displays the save mode of the data continuous motion or other Camera Number Displays the camera channel number of recorded data 7 3 2 Playing data L Double Click the Divar MR Archiv
108. y Systems Digital Video Recorder Safety en 5 All pole power switch Incorporate an all pole power switch with a contact separation of at least 3 mm in each pole into the electrical installation of the building If it is needed to open the hous ing for servicing and or other activities use this all pole switch as the main disconnect device for switching off the voltage to the unit Battery replacement A lithium battery is located inside the unit enclosure To avoid danger of explosion replace the battery as per instructions Replace only with the same or equivalent type rec ommended by the manufacturer Dispose of the replaced battery in an environmentally friendly way Refer all servicing to qualified service personnel CAUTION Class Laser Product Invisible laser radiation when open Avoid exposure to beam This warning is applicable only to those models that contain an internal DVD burner which uses a certified Class laser Coax grounding Ground the cable system if connecting an outside cable system to the unit Connect outdoor equipment to the unit s inputs only after this unit has had its grounding plug connected to a grounded outlet or its ground terminal is properly connected to a ground source Disconnect the unit s input connectors from outdoor equipment before disconnecting the grounding plug or grounding terminal Follow proper safety precautions such as grounding for any outdoor device con
109. ys via the supplied 25 pin D type connector board Connect PTZ cameras or DVRS EJ Connect a Bosch CCTV keyboard unit to the KBD IN socket E Connect audio line input Connect to your network via the Ethernet port or use the RS232 connector to connect directly to a PC serial port for service purposes Connect monitor B to the BNC output MON B Connect monitor A to the BNC output MON A Connect a VGA monitor a y py pn ORO D Connect optional extension USB devices e g mouse memory stick Camera connections Connect cameras to the unit using 75 ohm video coaxial cables with BNC connectors There are two BNC connectors for each camera Either connector can receive a camera s signal This signal is looped through directly connected to the other connector so that you can send the camera s signal to other equipment The camera input connectors are auto terminating so you do not need to add a terminator to the output connector if no additional equipment is connected If the camera signal is looped through to additional equipment make sure that the end of the video line is terminated with a 75 ohm terminator Monitor connections Connect the unit to the monitors via 75 ohm video coaxial cables with BNC connectors The unit provides a 1Vpp CVBS signal If the monitor has a loop through connection and you are not using the loopthrough output then select the 75 ohm impedance setting on the monitor If the monitor s loo

Download Pdf Manuals

image

Related Search

Related Contents

Tristar BP-2965  Spectracide HG-96095 Instructions / Assembly  2015 International Owner`s Manual  Plantronics Audio 910 Bluetooth Headset  Caméras infrarouges hautes performances Ti400 - EURO  製品仕様書    memorial descritivo e especificações técnicasapêndice 1 ao anexo 4  IO テスト FITC 標識抗体 CD5 IOT1a 形状・構造等(キットの構成) 操作  オートブレーカ・漏電遮断器 外部操作ハンドル 取扱説明書の台紙色変更  