1. User s Manual amp Operating Instructions Model Numbers MH 150T DFV MH 220T DFV HEATER SHOWN WITHOUT SAFETY GUARD PLEASE ATTACH SAFETY GUARD BEFORE USING HEATER CONSUMER READ AND SAVE THESE INSTRUCTIONS PONT di GENERAL HAZARD WARNING READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING STARTING OR SERVICING THE HEATER Be sure to comply with the instructions and warnings provided with this heater Failure to comply can result in fire or explosion that can cause property loss bodily injury or loss of life Only persons who can follow and understand these instructions should operate or service this heater If you need heater info such as an operating manual labels etcetera contact Pinnacle Products International at 800 641 6996 yf AM cu NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvented portable heater that uses air Oxygen from within the area in which it is used Failure to provide adequate combustion and ventilation air will result in asphyxiation carbon monoxide poisoning bodily injury or death Refer to Ventilation on Page 6 For Replacment Parts Visit www PartsFor com 70 400 0200 14 MAG TER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Table Of Con
2. plugged in it can start at anytime in accordance with the thermostat setting Dual Fusion Forced Air Heater User s Manual MAG TER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Specifications MH 220T DFV Pump Pressure PSI 71 111 56 93 Volts AC Hz 120VAC 60 Hz 120VAC 60 Hz Specifications subject to change without notice Features Models MH 150T DFV MH 220T DFV Front Safety Shell Control Panel Guard Rear Guard Rear Handle Power Cord Front Handle Wheel Fuel Gauge Fuel Cap Fuel Tank Drain Plug Figure 1 2014 Pinnacle Products International Inc 3 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Model MH 150T DFV MH 220T DFV Remove the heater and all packaging Tools Needed materials from the shipping carton Phillips Head Screw Driver 8 mm open end wrench 19 mm open end wrench DA Tip Use a power screwdriver and locking wrench for easier assembly Tip Be sure to remove the axle from the side of the Styrofoam packaging What s In The Box Safety Guard 1 Axle Nuts 2 Spacers 2 Spare Drain Plug 1 Front Handle Rear Handle Missing Parts Please Call 800 641 6996 For Assistance 2014 Pinnacle Products International Inc 4 Dual Fusion Forced Air He
3. with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Not For Indoor Use Indoor use permitted only for the temporary heating of buildings under construction alteration or repair CARBON MONOXIDE POISONING PUCES AY LEAD TO DEATH Refer to Safety Information on pages 1 2 for information about Carbon Monoxide Poisoning ALWAYS provide a fresh air opening in the heated space of at least three square feet 2 800 sq cm for each 100 00 Btu Hr of heater output Provide a larger opening if more heaters are being used Minimum Ventilation Opening Needed MH 150T DFV MH 220T DFV O it 6 5 ft 3 60 cm 5990 cm Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation Starting the Heater Iqnition Control Panel 1 Fill the tank with kerosene or other approved fuel until needle on fuel gauge points to F 2 Replace fuel cap and tighten firmly 3 Connect the heater to a three prong grounded power source You must use a three prong grounded extension cord that is at least 6 feet long and is a minimum of 14 AWG rating 4 Press the power button to power on the heater 5 Select BTU output setting using BTU HI LO buttons 6 Select desired temperature using temperature HI LO buttons 7 The heater will ignite once the temperature setting is higher than the ambient t
4. 8 EE 7 D ir 2014 Pinnacle Products International Inc 10 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Troubleshooting Guide Locating Your Serial Number Your serial number can be found on a white label on the right side cover of your heater It will begin with 2 digits the letter H followed by 6 digits For Example 13H123456 Have your Serial Number ready before calling customer service at 800 641 6996 Possible Cause Heater Ignites but main PCB shuts off after a short period of time LED display shows E1 Heater will not operate or motor runs for a short time LED display shows E1 Fan does not operate when heater is plugged in and power switch is in the ON position LED display shows E1 or E2 Poor combustion and or excess soot production Heater does not turn on and the lamp is not lit 2014 Pinnacle Products International Inc 11 Dirty input output or lint filter Dirty fuel filter Nozzle is dirty Photocell lens is dirty Photocell not installed properly Photocell is defective Improper electrical connection between main PCB and photocell No kerosene in the fuel tank Corroded spark plug or incorrect plug gap Dirty fuel filter Dirty nozzle Moisture in fuel tank Improper electrical connection between transformer and circuit
5. Exploded View 2014 Pinnacle Products International Inc 12 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Parts List Item Description MH 150T DFV MH 220T DFV 6 PowrPCBCase 70 027 1250 70 027 1250 8 _ Nozde 700 015 1000 70 015 1010 9 Air Dispenser 70 063 1000 70 063 1000 Intake Fuel Line 2014 Pinnacle Products International Inc 13 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR A WHILE CONNECTED TO A POWER SOURCE Parts List Item Description MH 150T DFV MH 220T DFV Front Handle 170 043 1002 170 043 1102 l 2014 Pinnacle Products International Inc 14 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Products International Inc warrants this heater to the original retail purchaser only to be free from defects in material and workmanship for a period of one 1 year from the date of initial purchase This product must be properly installed maintained and operated in accordance with the instructions provided Pinnacle Products International Inc requires reasonable proof of your date of purchase from an authorized retailer or distributor Therefore you should keep your sales slip i
6. Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims al warranties for products that are purchased from sellers other than authorized dealers or distributors AFTER THE PERIOD OF THE ONE 1 YEAR EXPRESS WARRANTY EXPIRES Pinnacle Products International Inc DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION FURTHER Pinnacle Products International Inc SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FRO ANY SPECIAL INDIRECT PUNITIVE INCIDENTAL OR CONSEQUENTIAL DAMAGES Pinnacle Products International Inc assumes no responsibility for any defects caused by third parties This Limited Warranty gives the purchaser specific legal rights a purchaser may have other rights depending upon where he or she lives Some states do not allow the exclusion or limitation of special incidental or consequential damages or limitations on how long a warranty lasts so the above exclusion and limitations may not apply to you Pinnacle Products International Inc does not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on Pinnacle Products International Inc Always be sure to specify the model number and
7. ater User s Manual GN MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Models MH 150T DFV MH 220T DFV 1 Insert axle through holes in wheel support 2 Slide then spacer onto axle 3 Slide wheel onto axle with the air valve facing out and hold in place with the axle nuts See Figure 2 Handle Safety Guard Wheel Support Frame Tire Place heater on wheel support frame and line up holes on the fuel tank lip Figure 3 Wheel Support Frame 5 Attach front handle with 4 long screws 50 mm and 4 nuts through the second and third hole from the front on both sides of the tank lip and wheel support frame and tighten firmly 6 Insert 2 short screws 30 mm through the first hole the front of in the tank lip and tighten firmly Make certain all 6 screws are secure 7 Attach rear handle with 4 long screws 50 mm and 4 nuts through the first and second hole from the rear on both sides of the tank lip and wheel support frame and tighten firmly 2014 Pinnacle Products International Inc 5 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Operation Fueling The Heater Kerosene 1 K For optimal performance of this heater it is strongly suggested that 1 K kerosene be used 1 K kerosene has been refined to virtually eliminate con
8. board Ignitor wire not connected to spark plug Defective ignitor Thermostat is set too low Broken electrical connection between main PCB and motor Dirty input output or lint filter Dirty fuel filter Poor quality of fuel PSI is too high or too low Temperature limit sensor has overheated No electrical power Fuse is blown Improper electrical connection between temperature limit sensor and circuit board Clean replace air or lint filter Clean replace fuel filter Clean replace Nozzle Clean replace photocell Adjust photocell position Replace photocell Check wiring connections Fill tank with fresh kerosene Clean replace spark plug Clean replace fuel filter Clean replace nozzle Rinse fuel tank with clean fresh kerosene Inspect all electrical connections Re attach ignitor wire to spark plug Replace ignitor Rotate thermostat to a higher setting Inspect all electrical connections Clean replace air or lint filter Clean replace fuel filter Flush fuel tank and refuel heater Use proper pressure Push power switch to OFF and allow heater to cool for 10 minutes Restart heater Check power cords for proper connection and test the power supply Check replace the fuse Inspect all electrical connections Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE
9. emperature in the space TIP If the heater does not ignite the thermostat may be set too low Increase the temperature to a higher setting until the heater ignites TIP If the heater does not ignite press power button to power off the heater check steps 1 3 above and press power a button to power ON the heater NOTE If if the heater still does not ignite Figure 4 refer to Troubleshooting Guide on page 11 Stopping Restarting Heater To stop the heater move the power switch to the Off position and unplug the power cord Torestart the heater wait 10 seconds and follow ignition steps 2014 Pinnacle Products International Inc 7 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Maintenance Long Term Storage Service 1 Drain fuel through the drain plug in the bottom of the fuel tank 2 To remove the drain plug pull the plug grip DO NOT TAMPER WITH THE UNIT HAVE downward and remove the seal head from the A COMPETENT SERVICEMAN MAKE ANY drain hole in the tank See Figure 5 NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operating conditions and will void your warranty i TIP To order OEM parts call 800 641 6996 Drain Plug We suggest following a maintenance schedule as follows FUEL FUEL TANK Dra
10. every 100 000 Btu Hr heater rating Refer to Ventilation on page 6 for further instructions 2014 Pinnacle Products International Inc WARNING RISK OF ELECTRIC SHOCK ALWAYS use only the electrical power voltage and frequency specified on the model plate of the heater ALWAYS use only three prong grounded outlet and extension cord ALWAYS use only 14 AWG or better extension cord ALWAYS unplug the heater when not in use ALWAYS install the heater so that it is not directly exposed to water spray rain dripping water or wind RISK OF BURNS FIRE AND WARNING EXPLOSION NEVER use fuels such as gasoline benzine paint thinners or other oil compounds in this heater NEVER refill the heater s fuel tank while the heater is operating or still hot This heater is EXTREMELY HOT while in operation NEVER block air inlet rear or air outlet front NEVER use duct work in front or rear of heater NEVER move or handle heater while still hot NEVER transport heater with fuel in tank NEVER use with an external fuel tank AWARNING CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN ANIMALS CLOTHING AND COMBUSTIBLES AWAY FROM HEATER Keep all combustible materials away from this heater Minimum Clearance From Combustibles MH 150T DFV MH 220T DFV En Sides _ Front _ ALWAYS locate heater on a stable and level surface If your heater is equipped with a thermostat once it is
11. in Plug Grip Flush tank every 200 hours of operation or as needed Pull Down gym TIP Follow the long term storage 3 Using a small amount of kerosene rinse and instructions to flush the tank swirl the Kerosene inside of the fuel tank empty the tank fully DO NOT flush with water use fresh 1 K kerosene only 4 Toreplace the drain plug push the drain head fully into the drain hole and secure by pushing the seal cap fully into the head hole See Figure 6 Drain Plug Fuel Tank Seal Head Head Flange Seal Cap 7 CE a Figure 6 IMPORTANT Never store leftover kerosene between seasons using old fuel can damage heater 2014 Pinnacle Products International Inc 8 Dual Fusion Forced Air Heater User s Manual MASTER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Maintenance Service Continued SPARK PLUG FAN BLADES Blades should be cleaned at least once per heating season depending on conditions Remove all accumulated dust and dirt with a damp cloth taking care not to bend any of the fan blades Be sure the blades are dry before re starting the heater For fan assembly removal see Figure 7 Siroco Fan Set Screw Motor Shaft Fan Blade FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean 1 K Kerosene Contaminated fuel could make cleaning the fuel filter necessary immediate
12. ly NOTE To remove the filter from models turn filter 90 counter clockwise See Figure 8 Fuel Filter Fuel Tank Figure 8 2014 Pinnacle Products International Inc Clean and re gap every 600 hours of operation or replace as needed After removing the spark plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5mm See Figure 9 Gap 3 5 mm Ignitor Wire Spark Plug Burner Head Figure 9 PHOTOCELL The photocell should be cleaned using a cotton swab dipped in alcohol or water at least once per heating season or more depending on conditions See Figure 10 CD FE Photocell lens Photocell Wire Figure 10 Dual Fusion Forced Air Heater User s Manual MAG TER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Maintenance NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary immediately To clean dirt from nozzle blow compressed air through nozzle front It may be necessary to soak the nozzle in 1 K kerosene to loosen any dirt particles Nozzle Face il K NN A Z CEN Aq gt Blue SG mue J Limit Control B Yellow Ignitor Wh iN A Sn ie P Sol Igniter Motor Condensor Power Pump gn O LR gt ER Le a Le LU 1 O EL Cc TNR2 AC 250V 3A I gt 4 ok R1 rues RY2 RY3 RY1 co ce EB dT P 6 JP3 CN
13. nvoice or cancelled check from the original purchase This Limited Warranty shall be limited to the repair or replacement of parts which prove defective under normal use and service within the warranty period and which Pinnacle Products International Inc shall determine at its reasonable discretion This warranty does not apply to products purchased for rental use This Limited Warranty does not cover any failures or operating difficulties due to normal wear and tear accident abuse misuse alteration misapplication improper installation or improper maintenance and service by you or any third part Failure to perform normal and routine maintenance on the heater shipping damage damage related to insects birds or animals of any kind and damage due to weather conditions are also not covered In addition the Limited Warranty does not cover damage to the finish such as scratches dents discoloration rust or other weather damage after purchase All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser Upon receipt of damaged item Pinnacle Products International Inc will examine the item and determine if defective Pinnacle Products International Inc will repair or replace and return the item freight pre paid lf Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This
14. ons should use or service this heater AWARNING DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT AWARNING CALIFORNIA RESIDENTS This product contains chemicals including lead known to the State of California to cause birth defects or other reproductive harm Wash hands after handling MASSACHUSETTS RESIDENTS Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation Use of this heating device in Massachusetts requires local fire department permit M G L C 148 Section 10A NEW YORK CITY RESIDENTS The New York City Fire Code prohibits the storage handling and use of kerosene fueled heaters for space heating Any person violating that provision may be punished by a fine up to 10 000 and a term of imprisonment of up to 6 months THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION ma Look for this icon throughout the manual for helpful tips on how to assemble use and clean your DFV Heater 2014 Pinnacle Products International Inc 1 Dual Fusion Forced Air Heater User s Manual MAGS TER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR o WHILE CONNECTED TO A POWER SOURCE Safety Information RISK OF INDOOR AIR A WARNING POLLUTION The products described in this manual are kerosene direct fired forced air heaters Kerosene f
15. orced air heaters are primarily intended for use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 combustion efficiency but does produce small amounts of carbon monoxide CARBON MONOXIDE POISONING ACER AY LEAD TO DEATH Carbon monoxide is toxic Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation Failure to provide proper ventilation in accordance with the instructions in this manual can result in death People with breathing problems should consult a physician before using this heater Early signs of carbon monoxide poisoning resemble the flu Symptoms of improper ventilation carbon monoxide poisoning are Headache Dizziness Nausea Dry Mouth Sore Throat Burning of Nose and Eyes If you experience any of these symptoms GET FRESH AIR AT ONCE Have your heater serviced and check for proper ventilation Some people are more affected by carbon monoxide than others These include pregnant women those with heart or lung problems anemia or those under the influence of alcohol or at high altitudes Not For Indoor Use Indoor use permitted only for the temporary heating of buildings under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outside air for
16. serial number when making any claim with Pinnacle Products International Inc For your convenience use the space provided below to list this information Register Your Product Online at http www masterindustrialproducts com Product_Registration php Locating Your Serial Number Your serial number can be found on a white label on the right side cover of your heater It will begin with 2 digits the letter H followed by 6 digits For Example 13H123456 Have your Serial Number ready before calling customer service at 800 641 6996 Model Serial Date of Purchase 2014 Pinnacle Products International Inc 15 Dual Fusion Forced Air Heater User s Manual ae PINNACLE INTERNATIONAL 2014 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com
17. taminants such as sulfur which can cause a rotten egg odor during the operation of the heater Using diesel fuel can cause excess soot production Do not use Bio Diesel as this fuel will damage your heater s seals and filter CSA certified for use with 1 K kerosene no 1 amp no 2 diesel JP8 Jet A Fuel no 1 and no 2 fuel oil DO NOT use any fuel that is not approved above NEVER REFUEL THIS HEATER PAANS WHILE IT IS HOT OR OPERATING FIRE OR EXPLOSION COULD RESULT NEVER FILL THE FUEL TANK A CAUTION INDOORS ALWAYS FILL THE TANK OUTDOORS BE SURE THAT THE HEATER IS ON LEVEL GROUND WHEN FUELING AND NEVER OVERFILL THE TANK DO NOT USE GASOLINE OR AWARNING CRANKCASE DRAININGS NEVER use fuel such as benzene alcohol white glass camp stove fuel paint thinners or other oil compounds in this heater THESE ARE VOLATILE FUELS THAT CAN CAUSE A FIRE OR EXPLOSION NEVER store kerosene in the living space Kerosene should be stored in a well ventilated area outside the living area NEVER store kerosene in direct sunlight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER 2014 Pinnacle Products International Inc NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene in a red container Red is associated
18. tents Safety Information 1 2 Wiring Diagram neu ee YW LI FF Lu neud 10 Features and Specifications 3 Troubleshooting Guide 11 PROS CMMI M EF RF NR 4 5 Exploded View 12 Operation 6 7 Parts r RH Y OO OI ARENA 13 14 Md iau eion WM _ ee Sa DOI a Wy FM EFENFF FD Y HN er 15 Sla gG EN de ee ee 8 Safety Information AWARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instructions Never use the heater in spaces which contain products such as gasoline solvents paint thinners dust particles volatile or airborne combustibles or any unknown chemicals This is an unvented portable heater It uses air Oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to Ventilation on page 6 Bulk fuel storage should be a minimum of 25 feet from heater DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS Failure to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosions burns asphyxiation or carbon monoxide poisoning Only persons who can read and understand these instructi