1. User Manual Off Grid Pure Sine Wave Inverter WI100 240 CNO1 V _ Tt Derr Please Read This User Manual Carefully Prior to Installation and Operation of This Product 2012 V1 0 C Pure Sine Wave Inverter User Manual WI100 240 CNO01 Notice 1 2 3 4 5 6 7 a Battery reverse connection is forbidden a Connection to utility is forbidden the inverter must be separately wiring Battery virtual connection or damage is one main factor of malfunction Please check battery voltage and connection status weekly clear rust on positive negative terminal in time use lead terminal if available If the apparatus alarms should identify the reasons and repair before re use Immediate restarting shall be forbidden In order to ensure the safe and normal work the total power of load should not exceed the rated output capacity If the load is inductive load such as refrigerator generator washer water pump etc user should use inverter capacity 5 6 times as load power and load should be switched on one by one Do not switch them on frequently If the malfunction is not easy to eliminate or reason unclear please write down the phenomenon in detailed record and contact manufacturer for help in time Three phase inverter can not connect to single phase load Installation Environment 1 2 3 4 5 6 1 The inverter should be put indoor where is well ventilated Avoid exposing the a
2. ad and wiring remove the short circuit hazard or damaged load then restart the inverter again Improper installation Installation should be in well ventilated areas Over temperature The vents are blocked Make the area around fan cover clean protection Something wrong with the fan Contact manufacturer Inverter switch is in OFF Turn on the inverter position LCD displays HIGH BATTERY LOWBATTERY OVERLOAD HIGH TEMPERATURE No AC output Please refer to the above corresponding solution 7 Guarantee and Liability One year warranty is available for our product from the date of delivery If the product is out of warranty or damaged by transportation inappropriate operation human factors force majeure no guarantee 1s made Pure Sine Wave Inverter User Manual WI100 240 CNO01 Appendix Appendix I Copper Wire Over Current Capacity Wire Diameter mm7 Over current Capacity A Wire Diameter mm7 Over current Capacity A
3. drive load lt Optional light control and time control function According to illumination intensity the inverter can control output without manual operation This function is available with our matched controller 4 Installation Flow Step 1 Check the package and then check the controller for damage after unpacking Damaged inverter cannot be installed in the system Note Wire connection diagram please refer to Appendix Step 2 Make sure the IVT SWITCH in the position of OFF Step 3 Connect battery to BATTERY terminals with copper wire Though the inverter has anti reverse connection protection function but wrong polarity of battery shall be forbidden Note Copper wire diameter please refer to Appendix I Step 4 Connect load to AC OUTPUT socket or terminals Step 5 Turn on IVT switch if necessary and AC load works the green IVT LED light will turn on Then the inverters work and supply alternating current to the AC OUTPUT Step 6 If the inverter has the by pass function connect Utility grid to AC INPUT socket or terminals of the inverter When battery is over discharge the inverter will intelligently switch to utility grid and supply power for driving load Step 7 Check all the connections to be correct and firm Pure Sine Wave Inverter User Manual WI100 240 CNO1 5 Technical Data Input over voltage protection Battery under voltage protection Protectio
4. n Functions Battery anti reverse connection protection Output overload protection Output short circuit protection Over temperature protection In order to serve our customers better our company can adjust parameter configuration according to customer s requirement Pure Sine Wave Inverter User Manual WI100 240 CN01 6 Troubleshooting Battery wire connection loose Check connection reconnect battery cables firmly 1 Check battery voltage until battery voltage reaches to inverter Battery voltage is lower than working voltage aca has no inverter working voltage 2 Check battery connection please reconnect correctly or display increase battery banks LCD wiring connection loose Open inverter box reconnect LCD wiring Input over voltage LCD display HIGH BATTERY please disconnect all the Battery is over voltage i protection wirings first and then re connect them Battery over LCD displays LOW BATTERY After battery voltage rises up discharge Battery is under voltage to the over discharge recovery voltage the inverter will recover protection automatically LCD displays OVER LOAD constantly Turn off the inverter Over load Load power exceeds inverter and check the load deduce some loads then restart the inverter protection rated output capacity again LCD displays OVER LOAD flashing Turn off the inverter Load short circuit Short circuit on the AC LOAD check lo
5. pparatus under direct sunshine exposure rain moist acid mist and dust Allow at least 20 inches 0 5 m distance from battery Ambient Temperature is 20 55 C Ambient Humidity is 35 85 RH no condensing If the apparatus is used in the area of altitude higher than 1000m output power should be lower 5 for usage accordingly with every 1000m increasing A Do not install the equipment in a compartment with flammable liquids such as gasoline or explosive vapors Be ware of flame and spark Product Introduction Off grid pure sine wave inverter is intelligent equipment which can transform the direct current to stable alternating current The apparatus is used to supply for Traffic inconvenience the harsh environment of the mountain area a pasturing area border islands and other areas without electricity The apparatus has decent appearance easy operation and visual indication of LCD with the perfect protection function high charging efficiency and low no load loss l CE Pure Sine Wave Inverter User Manual WI100 240 CNO01 2 Model Specification Feature Optional Fuction Rated Output Voltage Rated Battery Voltage Rated Output Capacity Product Name eo az e Wv ma a o vA ov sheienise m asm ea ane avn Tmovsmuemew o Dy coaer IKVA 230V Single phase Ea 04 Dry contact 60Hz _ Ey Ea x 2KVA 240V Single phase 3KVA 220V Three phase Horizontal Type 60Hz 380V Three phase 2 D soo
6. vtinee phase f oo E sisvtireephase oo E G WI100 240 CNO1 indicates rated output capacity 10kVA rated battery voltage 240V and rated output voltage 380V 300 three phase normal optional function output frequency 50Hz 3 Performance Description lt Reliability Intelligentized modularized simple structure design with powerful function and stable performance the high quality components and the strict production process make the inverter suitable for severe environment It also has reliable performance and long lifespan lt Pure Sine Wave Output Compared with square wave and modified sine wave the inverter has stronger load capacity The apparatus can drive inductive load and any other AC load within the required power lt LCD Display The LCD display battery voltage AC output voltage and status parameters Remark If inverter output capacity lt IkVA AC output voltage will not display High Efficiency Transformer Isolation Power frequency toroidal transformer which ensures high efficiency and 2 CE Pure Sine Wave Inverter User Manual WI100 240 CNO01 low no load loss of the inverter lt Perfect Protection Function Battery over voltage over discharge anti reverse protection output over load short circuit over temperature protection lightning protection etc lt Optional by pass function When the battery is over discharge the inverter will intelligently switch to Utility grid to