1. When desired room temperature is reached the main burner flame goes off but pilot flame stands alight No external power supply is needed to control of pilot flame main flame and thermoelectric safety features 20 Burner pressure atmaximumload mbar 1 2 z2 Heat intput at maximum load 3 0 4 Burner pressure at minimum load mbar 3 Jo o o e Heat intput at minimum load Net efficiency at max load 87 _ nN an nN aed a ii r 1 05 0 41 0 3 229 p n si co a Nozzle diameter main burner mm Nozzle diameter pilot burner mm f mth 0 322 0 127 0 505 240 242 60 150 172 Gas consumption at max load oO Flue gas temperature at max load Flue outletfair suction diameter Gas inlet size 22 23 5 with fan 30 31 5 with fan 630 220 Tjz 2 O 5 x z o 2 ae g gt 3 3 3 ake 3 605 ft ol Width Convection fan Available only for F models 230 50 Hz Only for F models 18 Only for F models Electrical properties Power consumption Delivery term Your heater is delivered in 2 packages 1 Heater pack which holds the Adarad convector this manual and wall fixing elements 2 Balanced flue kit pack Safety warnings A Before installation ensure that the local distribution conditions identification of the type of gas and pressure and the and the adjustment of the appliance are compatible Working surfaces of the convector a
2. S F Installation and User Manual C Distribuitor CALOR SRL Str Progresului nr 30 40 sector 5 Bucuresti tel 021 411 44 44 fax 021 411 36 14 www calorserv ro www calor ro Thank you for purchasing Adarad convector Please read this manual carefully before installation and operation of your appliance and keep it during the whole operation life Do not touch or interfere any part of the appliance other than those allowed The installation and service of this heater requires authorised and skilled staff For the installation of the heater and proper room selection this manual and mandatory regulations must be considered Adarad AC convector is a gas fired balanced flue room heater for independent use The heater must always be used with supplied telescopic flue kit in accordance with the instructions given in this manual As it does not use the air of your living room for the combustion a safe operation is ensured Thanks to its cast iron design your heater will perform a very long operation life with a silent combustion and high efficiency Some models are equipped with a convection fan which helps warm faster Convection fan is either switched on or off using the fan button on the control panel Adarad AC convector has an integrated multifunctional gas valve which modulates the gas flow according to desired room temperature between 13 and 38 oC The desired room tempearure is set by a thermostat knob on the control panel
3. USER INSTRUCTIONS Fan ON OFF switch optional Control panel The sketch on the right side shows the control panel of the heater e x You can reach the control panel by unlocking the button on the plastic cover on the a front panel During operation this cover is recommended to be kept locked Piezo The markings on the the thermostat knob refer to the following information ignitor Off position Ignition and pilot flame laseed Minimum setting of gas valve 4 6 intermediate warming 7 Maximum warming The working range of thermostat is from 13 to 38 C room temperature The adjustment of thermostat knob refers approximately to the following room temperatures Knob setting 1 2 3 4 5 6 7 Turning the appliance ON Starting from OFF position turn the knob to the pilot position Push the knob and ignite the pilot flame keeping the knob pressed for several seconds Release the knob after kept pressed for 10 seconds check that the pilot flame remains alight If it goes out repeat the ignition operation Room temperature setting Turn thermostat knob to set the main burner gas flow Stand by To keep the main burner of the stove closed and the pilot flame alight turn the knob from the selected temperature position to the pilot position Shut off the appliance Turn the knob to OFF position For seasonal shutdowns it is recommended to cut the gas supply to the appliance Switching fan on off OPTIONAL If your he
4. ater has an integrated convection fan you can either switch it on or off according to your desire Convection fan speeds the warming time up when in use increasing the efficiency of the heater at around 1 2 When the thermocouple thermoelectric safety device has cooled sufficiently pilot ligthing procedure may be repe ated After the appliance has been completely shut off re ignition is possible after about 1 minute to allow the thermo couple to cool If thermoelectric safety device actuating the flame is extinguished either intentionally or unintentionally no attemp should be made to relight the gas until at least 3 minutes have elapsed for safety reasons If the appliance goes off by any cause or stopped by turning main gate valve or governer off first set the thermostat knob to OFF position and wait for 5 minutes prior to re start Thermostat knob Maintenance and cleaning Your heater has no user servicible parts At the beginning of each heating season we would recommend to call for a service agent and request the following controls 1 Check of adequate gas supply from the net gas and combustion circuit soundness flue outlet terminal 2 Replacement of any material damaged lf needed you can clean the outer jacket of the convector with a piece of smooth cloth Never use sharp materials and cleaning solvents to clean the appliance Conversion to different gases Your appliance is adjusted at the factory for the local distribu
5. attached flue kit through the hole on the wall 5 Fix the flue terminal pos 4 onto the other en of the external pipe of flue kit via three self tapping screws supplied in the flue kit pack in such a way that when you finish the installation the flue terminal pos 4 should be levelled off with the outside wall surface You can adjust the total length of flue kit respectiveliy during this stage as well 6 When you finish the installation you should have the same view of the system as seen in the sketch on the right hand side below The space between the flue terminal pos 4 and outside wall surface must be selaed with silicon sealant The clearance between flue kit dia 150 mm and the circular hole for flue kit that you drilled on the wall must be sealed with silikon sealant plaster or cement OOR O AI RI SO ORRORE OIR DIR S Fy o y YN AR Ro y 6 Min 85 l l 4 i A LA i i i 630 L i O N C J If flue terminal is not arranged properly the performance of the heater may be attected in strong wind and rain Electrical installation only for versions with convection fan The versions supplied with convection fan should be connected to the mains with supplied original plug Please be sure that the supply you use for the heater matches with the electrical properties of the appliance This appliance must be earthed Check before starting
6. hould be insulated from the appliance Following clearances around heater must be ensured if surroundings are of combustible material Minimum distance from heater to side walls and upper items 30 cm Minimum distance from heater to the floor 7 cm 3 Curtains should not be kept closer than the minimum clearances specified above to the heater 4 Heater should not be positioned just between two side walls preventing warm air circulation around the heater 517 367 Installation Follow the procedure step by step 1 Drill a hole whose diameter not smaller than 150 cm for balanced flue kit To fix the heater drill four holes regarding the references on the sketch on the right Fit the plastic anchors supplied in the heater pack into these four holes 2 Flue kit is of telescopic design and you can adjust the total length of the flue in respect with thickness of the wall where the heater is insalled 3 Fix pos 2 of flue kit on corresponding holes on the heater air inlet chamber via pos 5 self tapping screws supplied in the heater pack After this attachment ensure that flue outlet ring dia 80 mm on the heater firmly and squarely fits into the internal pipe of the flue kit to prevent burnt gas leakage to fresh air side If you do not manage bad emissions during combustion will rise from the flue terminal to outside 4 Fit the heater onto wall fixing it via four pieces of anchor screws supplied in the heater pack driving the
7. re shown in the sketch on the right side As these surfaces become too hot during operation they must not be touched by hand Do not use the appliance if the flame inspection glass is damaged Do not use the convector without having the flue kit properly installed or if there is leakage on the flue system If balanced flue terminal outside neighbors a window please keep this window closed any time your heater is in operation If you feel gas leakage first turn the main gas valve in front of the heater off Do not switch any light and electrical appliance on or off Allow more fresh air circulation in the room call for service agent or local gas company Your heater should not be fired with any source other than installed pilot ignition system The terminal of the flue will reach excessive temperatures and then not be touched For this reason the flue outlet should not bepositioned to the walls in reach of people or should be protected z Ez I z z Q INSTALLATION INSTRUCTIONS Room arrangement Refer to the followings to find the proper place for heater installation 1 The hermetic flue kit of the heater must be installed through a wall next to outside where there is enough air circulation for combustion The flue terminal can not be routed to balconies ventillation or lighting clearances other rooms 2 If the heater is to be installed onto a combustible material such as wall paper his material s
8. ted natural gas at your location If needed the exchange from natural gas to LPG can only be carried out by registered service agent or authorised people from your local dealer Never interfere the setting of the appliance on your own Manufacturer s declaration of conformity We Adarad Dokum Urunleri Sanayi ve Ticaret AS located at Organize Sanayi Bolgesi 16400 Inegol Bursa Turkey TR declare under our sole responsibility that the Gas fired independent balanced flue space heater models Adarad AC2 AC3 AC4 AC5 AC2F AC3 F AC4F AC5SF to which this declaration relates is in conformity with the following standard s and normative document s Council Directive 90 396 EEC on the approximation of the laws of the Member States relating to appliances burning O gaseous fuels Harmonized normative EN 613 2000 on Independent gas fired convection heaters We declare that we have taken all necessary measures to ensure that the manufacturing process including final product inspection and testing results in homogeneity of production and conformity of the appliance with the type as described in the EC type examination cerfticate and with the requirements of above Directive with the type as described in the EC type examination cerfticate and with the requirements of above Directive Adarad Dokum Urunleri Sanayi ve Ticaret AS Rev November 2010 acafad Gas Fired Balanced Flue Heater Models AC2 AC2 F AC3 AC3 F AC4 AC4F AC5 AC
9. the heater if there is proper earthing on the mains Gas supply The design and installation of gas circuit to the appliance should be carried out by authorized staff licenced by local gas authority and in accordance with mandatory regulations The local gas supply company should always be contacted at the design stage to ensure an adequate supply is available Do not let unathorised people to interfere the existing gas supply setup in case of operation or gas pressure problems First consult your dealer or its contracted service agent If no problem on the appliance is found refer to local gas supply authority