Contents
1. 4 4 Door opening method setting 4 4 1 Card open Press 3 o 4 4 2 Card Password open Press 4 4 3 Card or Password open Factory default Press 4 5 Unlock time setting Press 4 0 99 Note The lock time range 0 to 99 seconds the factory default is 5 seconds 4 6 Alarm time setting Press 5 O 3 Note The alarm time ranges from 0 3 minutes the factory default is 1 minute 4 7 Magnetic Alarm Function setting 4 7 1 Shielding of the function factory default Press 6 0 4 7 2 Open the function Press 6 1 Open the function two possibilities 4 7 2 1 If the door is not closed properly for 1 minute the built in buzzer alarm will sound off 4 7 2 2 f the doors are unlock for 20 seconds after the doors are opened or if the doors are forced to open the built in buzzer alarm will soud off 4 8 Security mode setting 4 8 1 Normal mode factory default Press 7 0 4 8 2 Lock mode Press The system will lock and alarm after a ten minute continuous brush of an invalid keycard The system will also alarm after a continuous entry of a wrong password 6 2 Close door alarm tips Close the door or swipe card Valid card or input Administrator password Can stop alarm 7 Acousto optic instructions Operation Red Light Green Light Buzzer Note state Standby A Off Buttons Di SUCCESS Off On Di Failure DiDiDi P oi ou DI pes gt Set condition On On eee Slow flash Off Di U
2. magnetic switch another end connected GND Power supply 9 28V input 8 AC amp DC Red DC input 9 AC amp DC Black Power supply 9 28V input DC input Relay normally on end 1o Ne Mug Connected positive electric lock 11 COM Purple Relay Public end Connected GND 12 NC orange Relay Public end Connected negative electric lock 13 GND wa AC input for machines minus 01 U09 SS 99 y Figure 3 EniryVue AC 500 Keypad User Manual ENTRY VUE EM Metal Password Access Controller 8 3 2 Access Control Power Supply Cabling diagram Figure 4 Pink Wathet Blue vaio far me fo Door magnetic Brown switch Positive electronic lock Black BELL_A BELL _B ae O 0 ae ia 4 O o ct k _ OPEN ale f ee ne i electronic 5 on cee s oD I 01 U09 ssa00e piomMssedTe ap V ACTO shiedld ing HSNd layers Figure 4 9 Packing list Name MEAE Quantity Note neues specification If there is any problem please return the product to the Bask pees GAR 3008 i factory for maintenance Before installing the product on the wall please check the wiring User manual GAR 3008 l or line tube carefully to prevent accidents such as broken wiring Used for caused by drilling Please use saftey goggles when drilling or when Tapping screws 4mmx28 mm 4 in talictiog lixed fixing the line clip Used fo
3. card Metal Password Access Controller According to the model it respectively supports EM HID MIFARE three cards it is one of the most advanced stand alone access controllers It is designed with unique metal exterior dexterity keyboard panel operation built in high grade microprocessors strong anti interference ability Safety and reliability are extremely high it can provide powerful security for 2 000 users It contains strong functions such as low power consumption luminous keyboard independent passwords wiegand output output short circuit protection door magnetic alarm prevent demolition alarm exit button doorbell interface level of security Settings etc The product is widely used in homes offices residential areas and other public places 4 Administrator operation Restore factory settings Disconnect the power supply and open the back cover use the equipped two feet short circuit the inserting pin plugged into the machine rear Two short circuit seat then the machine buzzes then take short circuit namely the inserting pin for initialization of SUCCESS Figure 1 O He A Bi 6 OS oh Wie RESET Figure 1 Note restore factory Settings will not delete user data Enter administrator operation status Press Administrator password Administrator the defaultpassword 999999 Entry Vue AC 500 Keypad User Manual EM Metal Password Acce
4. Entry Vue AC 500 Keypad User Manual EM Metal Password Access Controller 2 Features TE Be Please read this manual carefully before Installation Low power consumption less than 30mA standby current Luminous keyboard keyboard can be operated at night User capacity support 2 000 users Independent password open the door with password which is irrelevant to the access card User modified password Users can revise the door password Search speed charge less than 0 1 S Output short circuit protection electric lock or alarm output circuit within 100 uS when shut down automatically output Wiegand output With Wiegand output interface Wg26 card number or Wg4 buttons output Usable keyboard delete card number After card is lost usable keyboard delete card thoroughly eliminate safety lapses The demolition alarm Illegal dismantling machine built in alarm sound buzzer The bell button and interface key and circuit segregation external any the doorbell 3 Technical parameters Work Voltage AC amp DC9 28V Static Current lt 30mA Reading Range 3 8cm Capacity 2000 users Ambient Temperature 25 C 60 C Ambient Humidity 10 90 Electricity lock output lt 3A Alarm output 20A Output short circuit protection time lt 100uS Open time 0 99 seconds adjustable Size 120 80 25mm 1 Product Profile ENTRY VY video interco UE stems The product is Contact less inductive
5. card are unrelated input a four digit code but not 1234 Delete user 4 3 1 Delete swipe card Press 2 Reading card Reading card E 4 3 2 Delete Designated card Number Press 2 4 3 3 Delete Designated ID Number Eight card number Eight card number L Press 2 ID No 4 3 4 Delete all Press 5 User operations ID No we 20000 Card modify password Reading card Old password New password L Repeat the new password H User ID number modify password ID No Old password L New password Repeat the new password Note applicable to a card or card less users if the user password is 1234 must use card to modify Card open Reading card A Press 5 2 Press 5 3 5 4 Press 5 9 Password open User password doors open doors open Card Password open Reading card User password doors open 6 Remove alarm operation 6 1 Swipe Valid card stop alarm or press Administrator password External alarm and built in buzzer alarm at the same time ENTRY V video intercom Ws UE stems
6. nlock Off On Di Alarm Fast flashing Off Alarm sound EntryVue AC 500 Keypad User Manual EM Metal Password Access Controller 8 2 8 Installation method lead wire description and Cabling diagram 8 1 Installation method 8 1 1 When installing on the wall take notice of the apreture size of drill to fit the connecting holes or installed two exisiting junction boxs plus connection Figure 2 Figure 2 8 1 2 Put the lead wire from bottom shell of the outlet hole connect the cables needed Unused lines are wrapped with insulating tape to prevent short circuit 8 1 3 When complete Install the front cover to the back cover tighten the screws stabilize the front cover and back cover 8 3 Cabling diagram 8 3 1 Ordinary power supply Cabling diagram Figure 3 ow FL ee aren Yelor Pa NO TIT T01 7U09 SS900e promssedTe yoy P B Positive A Blue p i electronic i _ Negative na NC Orange electronic lock Lead wire description ENTRY WUE video intercom stems Ine Marks Color Function description sequence 1 BELL_A Pink Doorbell button one end 2 BELL B Pale The doorbell button to the blue _ other end 3 DO Green WG output line DO 4 D1 White WG output line D1 Alarm negative alarm positive i APARM Crey connected 12V Exit button one end Exit button i OPEN Yelow the other end connected GND Magnetic switch one end 7 D_IN Brown
7. r Specifications will likely be different after product upgrades Stopper P 6mmx30 mm 4 installation fixed no prior notice will be made Star screwdriver 20mmx 0mm Secial Used between the front Star screws 3mmx mm cover and back cover for a fixed LED 1N4007
8. ss Controller 4 1 Modify administrator password Press 0 The new password Repeat he new password Note the administration password is between 6 8 numbers please be careful when entering 4 2 Add user 4 2 1 Add multiple cards 4 2 2 4 2 3 4 2 4 4 2 5 4 3 Press 1 Add designated card Number Press 1 Reading card Reading card L Eight card number Eight card number L Automatically adding the user ID automatically generated by this machine the range is 1 2000 and search from small to large Add designated ID Number swipe card Press 1 ID number Reading card ID number Reading card ne mia Add designated ID number and card number Press 1 ID number Eight card number ID number Eight card number al Note input ID digits of 1 4 digits The range is 1 2000 numbers such as 1 01 001 0001 ID number all expressed 1 Adding card user will automatically generate a default password 1234 but this password can not open the door the password is only for a user to change to a new password Add designated ID number and password Press 1 ID No password ID No password we E Note applicable to number card users password and
Download Pdf Manuals
Related Search
Related Contents
photo mechanic from camerabits Bedienungsanleitung DE Craftsman 358.79105 Trimmer User Manual Verona - OMRON Industrial Automation Canon 5128B001 Digital Camera User Manual "user manual" CE EMC TEST REPORT Highgrade A6041 Optima i.q. EAF-700/EAF-750 Faucet Installation Instruction Copyright © All rights reserved.