RS-232 Remote Control Software and Protocol USER`S MANUAL

image

Contents

1. po sa ULTRA RS 232 Remote Control Software and Protocol USER S MANUAL m Le CS Communications Specialties Inc WORLD HEADQUARTERS 55 Cabot Court Hauppauge NY 11788 USA TEL 631 273 0404 FAX 631 273 1638 WWW http Awww commspecial com EMAIL info commspecial com Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 TEL 65 6391 8790 FAX 65 6396 0138 EMAIL csiasia commspecial com Copyright 1999 P N 101677 Rev D Scan Do Ultra RS 232 Remote Control User s Manual 5 Included With This Product You Should Have r de ske eg 2 SDUltra The Windows Control Program 3 Connecting tothe RS 232 Remote 4 RS 232 Remote Control Protocol 5 2 3 5 Floppy Diskettes with SDUltra Win 3 1x program 2 3 5 Floppy Diskettes with SDUltra Win 95 NT program 1 RS 232 Remote Control User s Manual INTRODUCTION Communications Specialties Inc 55 Cabot Court Hauppauge NY 11788 USA TEL 631 273 0404 FAX 631 273 1638 WWW http www commspecial com EMAIL info commspecial com Communications Specialties Pte Ltd 180B Bencoolen Street 05 01 The Bencoolen Singapore 189648 TEL 65 6837 8790 FAX 65 6333 0501 WWW www commspecial com EMAIL csiasia commspecial com hank you for using the RS 232 Remote Control interface for T Scan Do Ultra an
2. 4 Click OK 5 Follow the instructions on the computer screen to complete the installation 1 Place the disk labelledSDUltra Win 95 NT Disk 1 in the drive of your PC 2 Click onStart icon 3 Click ontheRun icon 3 In the box for Open enter a setup 4 Click OK 5 Follow the instructions on the computer screen to complete the installation Operating SDUltrais very easy Just select the function you want from the Main menu or Main screen An extensive Help menu system is also available Scan Do Ultra RS 232 Remote Control User s Manual Page 2 CONNECTING TO THE RS 232 REMOTE CONTROL PORT The Remote Control RS 232 port on the rear oftheScan Do Ultra is astandard RS 232 9 pin port ADB 9 male to DB 9 female cable was provided withScan Do Ultrato connecta standard PC port to Ultra The configuration of the port is designed so that astandard straight through wiring DB 9 male to DB 9 female cable can be used to connect the port to a standard 9 pin serial port ona PC compatible The pin out for the Remote Control port is as follows DB 9 Remote Control Port Function 1 DCD RXD TXD DTR GND DSR RTS CTS No connection The baud rate and handshaking is determined by the settings for baud rate and handshaking established from the front panel of Scan Do Ultra Ifnothing has been selected thedefaultis 4800 baud No parity 8 bits 2 Stop bits No handshaking SDUItra has an extensi
3. BRIGHT NTSC BRIGHT NTSC CONTRAST NTSC CONTRAST NTSC CONTRAST NTSC COLOR NTSC COLOR NTSC COLOR NTSC HUE NTSC HUE NTSC HUE Scan Do Ultra RS 232 Remote Control User s Manual Page 6 LEVEL 3 COMMANDS RECOGNIZED IF NOT FREEZE Continued PAL BRIGHT PAL BRIGHT PAL BRIGHT PAL CONTRAST PAL CONTRAST PAL CONTRAST PAL COLOR PAL COLOR PAL COLOR RGB BRIGHT RGB BRIGHT RGB BRIGHT RGB CONTRAST RGB CONTRAST RGB CONTRAST RGB BALANCER RGBBALANCER RGBBALANCE G RGBBALANCE G RGB BALANCEB BALANCEB YUV BRIGHT YUV BRIGHT YUV BRIGHT YUV CONTRAST YUV CONTRAST YUV CONTRAST YUV COLOR YUV COLOR YUV COLOR Scan Do Ultra RS 232 Remote Control User s Manual Page 7 LEVEL 3 COMMANDS RECOGNIZED IF NOT IN FREEZE MODE Continued SAVE 1 SAVE 2 SAVE 3 SAVE 4 SAVE 5 RECALI 1 RECALL 2 RECALI 3 RECALL 4 RECALL 5 ZOOM 100 ZOOM ZOOM SIZE H SIZE H SIZE V SIZE V MOVE H MOVE H MOVE V MOVE V AUTOSET Note The AUTOSET command is notavailable from the front panel of Scan Do Ultra This command initiates an acquisition sequence which determines the input computer video s sync timing and sizes the image on the output screen ina 1 1 zoomratio Scan Do Ultra RS 232 Remote Control User s Manual Page 8
4. d Scan Do Ultra D Weare sure you will find itto be areliable and useful function with a wide array ofuses Like all the products from Communications Specialties the RS 232 Remote Control interface for Scan Do Ultra comes with our continuing commitment to provide support In order to assist us in this process please be sure to mail in your product registration card This will make it easier for us to notify you with any new product announcements or other information concerning our product line Should you need to contact us for support our office is open Monday through Friday from 8 30 AM to 5 00 PM Eastern Time We also offer comprehensive web site for your added convenience Thank you for choosing Scan Do Ultra As always we welcome your comments and suggestions Scan Do is a registered traderrark of Conmunications Specialties Inc Scan Do Ultra RS 232 Remote Control User s Manual Page 1 SDUltra THE WINDOWS CONTROL PROGRAM Installing SDUltra With Windows 3 1x Installing SDUltra With Windows 95 or NT This section describes the installation ofthe RS 232 Remote Con trol software called SDUltra which is provided on the enclosed disks in two versions A 16 bit version for Windows 3 1x A 32 bit version for Windows 95 and NT only 1 Place the disk labelledSDUltra Win 3 1x Disk I inthe A drive of your PC 2 From Program Manager in Windows 3 1x select File Run 3 Inthe box for Command Line enter a setup
5. or resetting This may be manually accom plished by sending the string 0000000000 ten zero s which would be recognized as an end of file marker INITIALIZATION STRING The Initialization String sent from Ultrais FF Scan Do Ultra Remote Control Ready BEL CR gt ERROR MESSAGES WHEN NOT IN DOWNLOAD MODE Error 1 Bad Syntax or ignored in standby Error 2 Bad Syntax or ignored in freeze Error 3 Bad syntax Scan Do Ultra RS 232 Remote Control User s Manual Page 4 STANDARD PROMPT FOR INPUT STRING CR gt LEVEL I COMMANDS RECOGNIZED EVEN IN STANDBY MODE STANDBY OFF STANDBY ON STANDBY DOWNLOAD VERSION BASE VERSION OPTION VERSION TEST PAT LEVEL 2 COMMANDS RECOGNIZED EVEN IN FREEZE MODE FREEZE ON FREEZE OFF FREEZE STATUS RESET ALL VF HF LINES LEVEL 3 COMMANDS RECOGNIZED IF NOT IN FREEZE MODE SOURCE 15 PIN SOURCE BNC SOURCE GENLOCK ON GENLOCK OFF GENLOCK PHASING H PHASING H PHASING SC PHASING SC Scan Do Ultra RS 232 Remote Control User s Manual Page 5 LEVEL 3 COMMANDS RECOGNIZED IF NOT IN FREEZE MODE Continued FORMAT FORMAT NTSC FORMAT PAL FORMAT VGA640 FORMAT MAC640 FORMAT VGA800 THRESHOLD THRESHOLD LOW THRESHOLD MEDIUM THRESHOLD HIGH LEVEL LEVEL LEVEL COMPONENT COMPONENT BETA COMPONENT M II COMPONENT RGBS COMPONENT RGSB TEST PAT TEST PAT OFF TEST PAT COLBAR TEST PAT GRYBAR TEST PAT HATCH TEST PAT CUSTOM NTSC BRIGHT NTSC
6. ve on line Help menu system to guide youin operation of the software Thefirsttime you launch SDUltra you musttell it what COM porton your PC the Scan Do Ultra is connected This is done by clicking onthe item Options on the Main menu and selecting a COM port Please note that a Scan Do Ultra must be connected to the PC and powered On for the SDUltra software to work Scan Do Ultra RS 232 Remote Control User s Manual Page 3 THE RS 232 REMOTE CONTROL PROTOCOL Upon reset or power up Scan Do Ultra will send an initialization string to the host Itis then ready to accept any commands below These commands must be in UPPERCASE ONLY These commands will do the same thing as ifthe user had pressed the appropriate buttons on the front panel of Ultra The front panel display will not be updated to reflect the command execution until the user re enters the corresponding submenu for the command after its execution Ifthe string sent to Ultra is not found to bea valid command a syntax error string is sent and the commandis flushed Ifaccepted the command string will be echoed back to the host on anew line and in parenthesis then followed by the input prompt gt on the next line The host should use CR to CRLF translation onthe inputin to the host but strip LFs on the output to Ultra The DOWNLOAD command is used to prepare for downloading code to Scan Do Ultra for test patterns There is no operational exit from the download mode except f