Home

User Manual

image

Contents

1. dosage rate see chart e lf ithe setting is not correct adjust unit to the correct setting Note For The Blend Center the dilution pin color determines the dosage rate The MixRite and Large Volume units use the adjustable blue sleeve as shown above right page 1 of 4 Proper Dosing continued 2 Water Supply pH Check to Confirm Proper Dosing Check the pH of your water Product Dosage Setting option 1 Setting option 2 Prepare a hand mix sample Add the correct oml L volume of liquid concentrate to L of water ener ae according to the chart to the right and mix then check the pH of the solution 16 ml L 20 ml L Interpretation o Ifthe pH values from the two measurements are within 0 1 pH units the unit is dosing properly o Ifthe pH of the sample from the unit lt the pH of hand mixed sample Over dosing o If the pH of the sample from the unit gt the pH of hand mixed sample Under dosing Proper Maintenance To maintain a clean properly operating system if is best to flush the system with fresh water at the end of each day One of the following procedures should be performed once a month 1 CLEAR SOLUTIONS Floralife Crystal Clear flower food 300 Clear 200 storage and transport treatment Clear ULTRA 200 storage and transport concentrate treatment and Special Blend 300 for pure water and for hard water q Insert the tube end that normally goes into the concentrate tank into a cle
2. through For service or repairs contact DEMA at 1 800 325 3362 Floralife a division of Smithers Oasis Company Flora 751 Thunderbolt Drive Walterboro SC 29488 800 323 3689 843 538 3839 www floralife com The Art of Flower Care Africa Asia Australia Central America Europe North America South America page 4 of 4
3. As the owner of a Floralife Dosing System you ll want to use the following information to keep your dosing unit at its optimum for a long life and for better quality product output The following procedures should help give you the answers you ll need Floralife features one of the three units shown fo the right The instructions given in this manual apply to all of these systems with a few exceptions that are listed A The correct dose of flower food maximizes flower life for maximum customer satisfaction When hand measuring each dose of flower food one offen approximates Severely underdosed solution could actually reduce flower life 7 and reduce customer satisfaction A No A Floralife Dosing Unit is adjustable It will leave the factory set at 1 You y can adjust this according to the product used PN A Yes The machine is covered under a 12 month manufacturer s warranty WIKIAN We recommend to use a professional plumber for installation Detailed installation ta instructions are included in the dispensing unit box No electrical hook up is required p The suggested water pressure by manufacturer is 3 120 psi for the MixRite and 15 125 psi for The Blend Center Also it is best if your water is contaminant free Liquid Products 1 Setting Check e First double check to make sure the setting on the dosing injector is correctly Suggested Products and Settings set to the recommendations for the product s
4. an plastic container filled with 1 gallon of Floralife D C D Caution Please follow all labeled safety precautions on D C D label set the dosing injector to the 1 ratio Run 1 quart of D C D through the dosing system properly discard the dispensed solution and let it set overnight minimum of 8 hours Wipe the unit clean with a warm wet cloth to remove any existing residues The next morning remove the tube from the Floralife D C D container and flush the tube with clean water Place the tube into the flower food concentrate Set the dosing injector to the correct setting based upon the flower food used See chart on page or label instructions Let the injector system flush any remaining D C D through the system until the flower food solution comes through the dispensing unit approximately 1 2 minutes Resume the use of the injector system with Floralife flower food for flower processing pia page 2 of 4 Proper Maintenance continued 2 NONCLEAR SOLUTIONS Floralife 200 storage and al M transport treatment and ULTRA 200 storage and transport concentrate treatment a Insert the tube end that normally goes into the concentrate tank into a clean plastic container filled with 1 gallon of Floralife HydraFlor 100 hydrating treatment for cut flowers set the dosing injector to the 0 5 ratio Run quart of HydraFlor 100 through the injector A d system properly discard the dispens
5. ed solution and let it set overnight minimum of 8 hours d Wipe the unit clean with a warm wet cloth fo remove any existing residues e The next morning remove the tube from the Floralife HydraFlor 100 container and insert it into a clean plastic container filled with 1 quart of D C D Run this through the dosing system Caution Please follow all labeled safety precautions on the D C D label f Remove the tube from the Floralife D C D container and flush the tube with clean water g Once done place the tube into the flower food concentrate Set the dosing unit to the correct setting based upon the flower food used see chart on M page 1 or label instructions T x h Let the injector system flush any remaining D C D through the system until the flower food solution comes through the dispensing unit approximately 1 2 minutes J y i Resume the use of the injector system with Floralife food for flower processing Special Note the above procedure must be done as a two step process DO NOT MIX Floralife HydraFlor 100 and Floralife D C D to make a single solution Be sure fo clean your dispensing system regularly page 3 of 4 Troubleshooting How often do need to clean my dosing system Why isn t any liquid being drawn up from the Floralife Flower Food concentrate bucket The concentrate solution bucket is filling up with water Only a small stream of water is coming