Home
HPS 749-R -ITA-
Contents
1. door Shock sensor Sense the broke of the door s window Ignition protection Sense the ignition of the car Ultrasonic Optional Sense the moving in the passenger compartment PIN code The PIN code is for that the user can switch off the alarm if the remote control or the alarm get wrong or the battery discharged In all boxes of the alarms can be found an envelop which contains a secret PIN code Only the user can open this envelop All alarms have different PIN code We suggest for the user as for the perfect safety to change the original set PIN code for a new own one Please follow the next instructions in the followings chapters If you have got any further problem in conncetion of the PIN code please look for only your importeur Open only by the USER The code is a 3 figures number from firm is 1 2 3 and must be composed with the ignition key of the vehicle by following this procedure With the alarm armed open the driver s door with key The alarm will trigger 1 Within 30 seconds after opening the door turn on and off the ignition key of the vehicle for 3 times If the operation is correct the LED of the dashboard switches on for 5 seconds IGNITION KEY Signalling LED With the alarm armed On Off On Off On off LED on open the The alarm switches on CDL of the vehicle O m the LED for 5 seconds The alarme will sound and within 30 seconds 1st time 2nd time 3rd time 2 When the LED switches ON 5 seco
2. USER MANUAL Hrs 840 PTL H Working ALARM System RMING Push the CLOSING button of the remote control The arming will be confirmed by Blinker flashings based on the lock features of the vehicle 2 beeps if it is programmed Switching on of the LED on the dashboard fixed light for 5 seconds Activation of electric engine immobilization if it is connected Activation of modules output windows lifter ultrasonic sensors etc The CDL close the doors Atarm System DISARMING Push the OPENING button of the remote control The disarming will be confirmed by 1 beep if it is programmed Switching off of the LED on the dashboard Deactivation of electric engine immobilization Deactivation of modules output windows lifter ultrasonic sensors etc The CDL open the doors Neutral Time and Status of Alert Once the signalling of arming is over the alarm will stay for 5 seconds into neutral time condition signalled by the fixed light of the LED After 5 seconds another flashing of the blinkers and the flashing of the LED of the dashboard will indicate that the system supervises the vehicle and is ready to signal the alarms Alarm In case of attempt to brake in the system will emit an optic acoustic signal flashing of the blinkers and sound of the horn or a sound of the siren if installed for 30 seconds repeated To stop the alarm signalling push the OPENING button of the remote control Exclusion
3. ces hydro jet or similar it is necessary to protect the alarm before starting the washing procedure In case of infiltrations of water caused by using the hydro jet the warranty will be automatically annulled GENERAL MAINTENANCE all the repairing operations to the alarm must be done by PATROL LINE centres tampering by non authorized staff can compromise the reliability of the device and the safety when the vehicle is going Note PATROLLINE KFT 8000 Sz kesfeh rvar Kir lysor 32 Hungary PATROLI LINE Tel Fax 36 22 317 367 503 078 E mail info riasztocentrum hu E E E Web www canbusriaszto hu www patrolline ro www autoalarmcanbus cz www patrolline eu
4. is phase LED flashing it is not possible to arm the alarm through the remote control of the vehicle To enable again the normal working of the alarm while the LED is flashing turn on and off the ignition key of the vehicle for 3 times IGNITION KEY signalling LED On Off On Off On off With the LED flashing The led stops turn on and off the Lp 0 O O 0 p flashing i kd ist time 2nd time 3rd time If the operation is correct after the third figure the LED will stop flashing From this moment the alarm will start its normal working Changing the Unlocking Code This operation permits to customize the emergency code from 1 2 3 to 2 1 2 to the one wanted by following this procedure Through the ignition key compose the old pin code as described in the previous paragraph IGNITION KEY On Off On Off On Off signalling LED With the alarm off manni BO OQ OQO amp ignition key 3 times e or 5 seconds 1st time 2nd time 3rd time To change the PIN code follow the next procedure 1 With the alarm armed turn on the ignition key 3 times then turn off the ignition key The LED switches on fixed for 5 seconds 2 When the LED switches on 5 seconds turn on the ignition key The LED starts flashing 3 Count the flashings of the LED After the first flashing turn off the ignition key the first figure of the PID code is 1 The LED switches on fixed for 5 seconds LED on for Turn on the maun starts Tur
5. n off the The LED switches on 5 seconds a key ashing ignition key for 5 seconds 0 gt gt 000000 gt First fiqure 1 4 Before the LED switches off 5 seconds turn on the ignition key The LED starts flashing Once reached the flashings of the LED corresponding to the figure that must me memorized turn off the ignition key If the operation is correct after the third figure the alarm switches on the LED for 10 seconds confirming that the new PIN CODE has been memorized and replaced the previous one 5 Count the flashings of the LED After the second flashing turn off the ignition key the second figure of the PIN code is 2 LED on for Turn on the The LED starts Turn off the The LED switches on 5 seconds en key flashing ignition key for 5 seconds 5 000 0 gt 6 Second figure 2 6 Before the LED swicthing OFF 5 seconds turn on the ignition key The LED starts flashing 7 Count the flashings of the LED After the third falshing turn off the ignition key the third figure of the PIN code is 3 The LED swicthes on fixed for 5 seconds LED on for Turn on the The LED starts Turn offthe The LED switches on 5 seconds eer key flashing ignition key for 10 seconds Off New PIN 0 gt lt gt 00000 gt 0 0 gt Third fiqure 3 8 When the LED switches on 5 seconds turn on the ignition key The LED starts flashing 9 Count the flashings of the LED After the second flashing turn off the igniti
6. nds turn on the ignition key of the vehicle The LED of the dashboard starts flashing 3 Count the flashings of the LED After the first flashing turn off the ignition key first figure 1 of the firm code The LED switches on for 5 seconds LED on ne Turn on the The LED starts Tum offthe The LED on 5 seconds oe key flashing ignition key for 5 seconds 0 000 gt 05 First figure 1 4 Before the LED switches off 5 seconds turn on again the ignition key The LED of the dashboard starts flashing 5 Count the flashings of the LED After the second flashing turn off the ignition key second figure 2 of the firm code The LED switches on again for 5 seconds LED on for Turn on the The LED starts Turn offthe The LED switches on 5 seconds yea key flashing ignition key for 5 seconds 0 gt gt 000 gt 0 gt Second figure 2 6 Before the LED switches off 5 seconds turn on again the ignition key The LED of the dashboard starts flashing 7 Count the flashings of the LED After the third flashing turn off the ignition key third figure of the firm code The LED switches on again for 5 seconds LED on for Turn on the The LED starts Turn off the The alarm switches off 5 seconds ignition key flashing ignition key and the LED starts flashing 0 gt 5 gt 000 gt 0 gt 000 Third fiaure 3 At the end of the third figure if the code is correct the alarm disarm and the led start flashing During th
7. of the Siren Through the ignition key it is possible to exclude the functioning of the horn or the siren With the alarm disarmed CDL opened turn on and off the ignition key for 3 times and within 30 seconds push the original remote control to close the CDL of the vehicle From this moment the central unit will signal the attempt to brake in by the flashing of the blinkers only Warning The exclusion of the siren is valid for only one cause of trigger If you switch OFF the alarm with the remote control the alarm will be restored automatically in the original state and for the next switching ON it will react with beep and acoustic signals for every cause IGNITION KEY On Off On Off On Off Push the original remote With CDL open O O O control to close the doors LED off 1st time 2nd time 3rd time di Memory of Alarm If the central unit records one or more causes of alarm they are signalled when disarming through the LED To verify the type of alarm check the number of flashings of the LED with the table below N flashings of the LED Cause 2 SIREN TRUNK BUTTON i INSTALLED 3 ULTRASONIC SENSOR ALARM input BLUE RED wire 4 SHOCK SENSOR 5 DOORS OPENING sicnattep sy Can Bus 6 BONNET OPENING sicnattep sy Can Bus 7 EXTRA SENSORS ALARM input BLUE wire 8 IGNITION PROTECTION Safety function Door protection Door trunk and bonnet open sense Motor blokk Prevent the start of the motor of the
8. on key the first figure of the new PIN code is 2 The LED switches on for 5 seconds LED on for Turn on the The LED starts Turn off the The LED switches on 5 seconds ignition key flashing oe key for 5 seconds 0 gt 5 gt 000 gt 05 6 First fiqure 2 10 Before the LED switches off 5 seconds turn on the ignition key The LED starts flashing 11 Count the flashings of the LED After the first flashing turn off the ignition key the second figure of the new PIN code is 1 The LED switches on for 5 seconds LED on for Turn on the The LED starts Turn offthe The LED switches on 5 seconds sal key flashing ignition key for 5 seconds 0 lt 000 gt 05 Second figure 1 12 Before the LED switches off 5 seconds turn on the ignition key The LED starts flashing 13 Count the flashings of the LED After the second flashing turn off the ignition key the third figure of the new PIN code is 2 If the procedure is correct the LED switches on for 10 seconds LED on for Turn on the The LED starts Turn offthe The LED switches on 5 seconds on key flashing ignition key for 10 seconds 0 2 gt 000 0 6 Third fiqure 2 ALARM MAINTENANCE The alarms of our range are based on a very high technology and are characterized by an extreme reliability Using some shrewdness it is possible make them living longer and working better Venicie Wasuine in case the vehicle has to be washed with some high pressure devi
Download Pdf Manuals
Related Search
Related Contents
Brochure WV FX Series Export Inverter/Charger Programing Manual Installation Manual Manual del Propietario Manuel d`utilisation DATA-MANSHRT_GX110_ITL_Rev B.p65 CARE AND USE MANUAL Geovision GV-650B-04 video capture board 取扱説明書 Téléchargez le manuel de directives Copyright © All rights reserved.
Failed to retrieve file