Home
ioMirror E3210 User`s Manual
Contents
1. a General Settings 0 Ethernet Configurations EX 1 OSettings DI Channels J DO Channels FGI ioMirror Settings ES System Management ra Accessible IP Settings i Network Connection LCM G Change Password Load Factory Default Save Restart On the Save Restart page you may save all configuration changes and reboot the I O server with the new configuration 3 gt Total Solution for Industrial Device Networking 3 Main Menu 3210 I Overview ac Basic Settings Network Settings sabi n if Warning Reboot will disconnect both serial and Ethernet connections and data maybe lost i r I General Settings Save Restart The configuration has been changed Please click to reboot with new configuration E Ethernet Configurations G 1 0 Settings ea DI Channels DO Channels a ioMirror Settings ae System Management ea Accessible IP Settings 5 Network Connection P LCM A Change Password A Load Factory Default 299955 85955005 564055080 0 5508 050080 3 9 4 IoMirrorAdmin and toEventLog Two Windows utilities ioMirrorAdmin and ioEventLog are included to help you manage your ioMirror server over the network The following topics are covered in this chapter O Overview O Installation O ioMirrorAdmin Searching for ioMirror Servers gt Wiring Guide gt ioMirror Configuration gt Firmware Update gt Restart System gt Reset to Default O oE
2. e any device connected to the alarm port will be activated e an error message is sent to the ioEventLog Under Alarm Settings you can enable or disable the alarm You can also specify where and how to send error messages with ioEventLog Server I P and TCP port no Module to Module and Channel to Channel modes Module to Module mode is used if you wish for all DI channels to be mapped to another ioMirror s DO channels Simply enter the destination IP address Channel to Channel mode is used if you wish to individually map DI channels to separate or multiple ioMirror servers For each DI channel enter the mapping destination s using Remote Module IP Address and Remote DO Channel If your ioMirror will also be receiving signals from another ioMirror server enter the mapping source for each channel using Acceptable Remote Module IP Address 3 6 ioMirror E3210 Using the Web Console Total Solution for Industrial Device Networking amp Main Menu E3210 o la i ioMirror Settings 9 Overview 1 Basic Settings HE Network Settings ES ioMirror ings ei I O Settings Common Settings Alarm Settings E ioMirror Settings Interval time 20 20 600000 ms Enable Alarm Ai System Management ae a LCM TCP Port no ioEventLog Server IP 192 168 19 60 fa Change Password r Load Factory Default Og Save Restart Time out 5 1 6000 sec TCP Portno 4040 O Module to Module mode Remote Module IP Channel to
3. 27 28 29 30 31 TI Today 5 10 2007 PEx Event type Event Date Time Source Name Source IP Destination IP Warm Start On Line Off Line On Line Off Line On Line Off Line On Line Off Line 1 6 2000 6 20 38 1 6 2000 6 20 41 1 6 2000 6 19 19 1 6 2000 6 19 19 1 6 2000 6 19 22 1 6 2000 6 19 22 1 6 2000 6 19 42 1 6 2000 6 19 42 1 6 2000 6 20 2 1 6 2000 6 20 2 10 alarm event s Clearing the Log 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 253 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 192 168 127 254 If you wish to clear the log you can select Clear from the Log menu This will clear all events for the current day The cleared events will not be saved in that day s logs After the logs are cleared new events will be displayed and recorded as usual 4 7 A LCD Display Kit The ioMirror supports an optional detachable LCD display kit also known as the LCM for easier field maintenance The LCD display kit is hot pluggable and can be used to configure the network settings or display other settings Controls The up and down buttons navigate between the current options The right and left buttons enter and exit the submenus The center button is used when modifying settings or restarti
4. e Remote signal display e Signal splitting e System monitoring e Tank level pump and valve control monitoring e Power station signal monitoring e Telecom machine room monitoring e Security signal display for factory office or public building 1 2 ioMirror E3210 Introduction Features High speed mirroring of digital I O signals over Ethernet The ioMirror E3210 transmits digital I O signals over Ethernet at very high speeds with less than 20 ms latency in a local area 100Mbps network The extremely low latency makes ioMirror E3210 an excellent choice for transmitting low and middle speed signals such as liquid level or optical sensor input e Easiest setup for digital output signals driven by remote input The ioMirrorAdmin utility for Windows makes it easy to configure input to output mapping both locally and remotely Basic Configuration is provided for module to module mapping Advanced Configuration is provided for more flexible channel to channel mapping and allows one digital input signal to be mapped to multiple digital outputs Remote configuration can also be completed using a web browser interface e Designed to use existing Ethernet infrastructure saving time and wiring cost With a high speed Ethernet infrastructure already in place there is no longer any reason to go through the expense and effort of laying down additional I O wiring Modern Ethernet fiber optic lines or WLAN can provide high speed connectivity
5. Channel mode Mirror lt local DI gt To lt remote DO gt Mirrored From lt acceptable remote Modules IP gt Local DI Remote Local DO rer Remote Module IP Address DO Ene Acceptable Remote Module IP Address Channel 0 0 1 1 System Management Accessible I P Settings Total Solution for Industrial Device Networking J Main Menu E3210 3 Accessible IP Settings am Overview P q Basic Settings E Network Settings gm General Settings C Enable the accessible IP list Disable will not allow all IP s connection request No Active IP Address Netmask E N 1 L _ J Ethernet Configurations E I O Settings O P1 DI Channels 3 O 3 DO Channels a ioMirror Settings 53 System Management A Accessible IP Settings da At adore te nm m ne On the Accessible IP Settings page you may control who has configuration access to the ioMirror by entering the permitted IP Address and Netmask When the accessible IP list is enabled only network hosts on the list may configure the ioMirror Use the accessible IP list as follows To grant access to a specific I P address use Netmask 255 255 255 255 To grant access to hosts on a specific subnet use a non trivial Netmask such as 255 255 255 0 To grant access to any network host disable the accessible IP list You may use the following sample entries for reference Desired Hosts IP Address Netmask gt 192 168 1 120 192 168 1 120 255 2
6. to 6431 38433 to 0x20FO 72 word Get all DI channels SAFE MODE status 38504 8432 to 8503 38505 to 0x2138 48 word Get all DO channels SAFE MODE status 38553 8504 to 8552 4xxxx Read Write Registers Functions 3 6 16 40001 0x0000 1word Alarm Enable 1 Enable0 Disable 40002 0x0001 ioMirror Alarm Timeout time Function 8 0x7008 28680 B 2 C Used Network Port Numbers IoMirror E3210 Network Port Usage Port Tye Usage ss 80 TP WebSever SS Modbus Communication 68 UDP BOOTPC 68 UDPP CCP 4045 4040 ioEventLog 4800 Auto search D Factory Default Settings The factory default configuration for the ioMirror E3210 is as follows Netmask 25525250 _ DI mode au DO mode w DO alarm status Off Password NONE NONE Location NONE off Pinouts and Cable Wiring The following topics are covered in this appendix O Port Pinout Diagrams gt Ethernet Port Pinouts O Digital I O Structure gt Digital Input Structure gt Digital Output Structure gt Alarm Output Structure ioMirror E3210 Pinouts and Cable Wiring Port Pinout Diagrams Ethernet Port Pinouts Digital I O Structure Digital Input Structure BV Isolated DI COM DIO DI 1 ioMirror E3210 Pinouts and Cable Wiring Digital Output Structure 5V Isolated Low side Switch ps DO O E DO I J el GND 3V Isolated Darlinton pair Alarm ut UND Ee E 3
7. 00 1 4 90 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 192 168 19 88 4107 400 40 an 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 192 168 19 85 4107 4100 40 NE 4 2 ioMirror E3210 ioMirrorAdmin and ioEventLog ioMirrorAdmin Searching for ioMirror Servers ioMirrorAdmin is designed for network operation You will need to find your ioMirror unit on the network to use any of ioMirrorAdmin s functions In the System menu select Auto Scan Remote I O Server This opens a search window which automatically searches the network for ioMirror servers Auto Searching for ioMirror E3210 1 1 0 server s were found I tt I 05ewer IP Address Port MAC Address Unit ID Description E3210 192 168 127 253 00 90 E8 11 54 4F ioMirror E3210 BDI 8D0 RRSESRSSERRRRB Search for I O mirror modules When the search is completed you will see a list of all ioMirrors If your ioMirror server is not located make sure that your computer and your ioMirror server are in the same subnet AOXA
8. 55 255 255 192 168 1 1 to 192 168 1 254 192 168 1 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 1 255 255 255 128 3 7 ioMirror E3210 Network Connection Using the Web Console On the Network Connection page you may view each TCP connection which can make it easier to manage devices and mappings You also can check which ioMirror units are disconnected for easy debugging The connecting protocol for each connection is indicated under Connection Type Web HTTP indicates a web console connection to the ioMirror ioMirror TCP indicates a connection to another ioMirror unit For ioMirror connections Direction is used to indicate whether digital input signals are being transmitted to the remote unit or being received from the remote unit 3 Main Menu 3210 a Overview Ea Basic Settings Network Connection Total connection s Bey Network Settings EH 1 0 Settings EEE z ped IP Address Direction Connection Type 3 ioMirror Settings E 192 168 16 141 Web HTTP Tal System Management 192 168 19 81 To ioMirror TCP I Accessible IP Settings Change Password a Load Factory Default 3 Save Restart LCM Total Solution for Industrial Device Networking On the LCM page you can check the status of the optional LCD display kit If it is installed successfully the statu
9. 9 88 192 165 19 58 192 165 19 58 192 165 19 58 192 165 19 55 192 165 19 58 AAA 1 1n a Destination IP 192 168 19 85 192 165 13 85 192 168 19 35 192 168 19 35 192 168 15 65 192 168 13 95 192 165 13 85 192 165 13 55 192 169 195 985 192 165 13 85 192 165 13 85 192 166 195 385 192 168 19 35 192 168 15 85 192 168 13 95 192 165 13 85 192 165 13 85 192 165 13 85 192 165 13 85 192 165 13 55 AMA 1 1n Ae The Alarm Listen Port is the TCP port number that will be monitored for status events You can modify this setting as necessary to receive signals through a firewall It will need to match the settings for the ioMirror server that is being monitored The Log Directory is where the log files will be stored The default directory is C Program Files Moxa ioMirror log A separate log file is created for each day with file names assigned automatically You can also select the Color for each event type in the log 4 6 ioMirror E3210 ioMirrorAdmin and ioEventLog Opening Log Files You can view previously saved logs by selecting Open from the Log menu You will be prompted for the date that you wish to view MOXA ioEventLog Sele System Log Help A Event Date Time Source Name ER IP Destination IP ere Event type Bk lt Date of Log File Select date of log file to view EE May 2007 Sun Mon Tue Wed Thu Fri 1 2 3 4 6 7 9 dp 13 14 15 16 17 18 20 21 22 23 24 2
10. Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 www moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents 1 Introdutaibhsrsaaaarqaaacaaaadrcaua de 1 1 A 1 2 FRUE 1 3 INSTITUTE POMPEII MST OT 1 4 ETIIETTCE NEO eg 1 4 Fer OPE NetWork seede ededadd NAG 1 4 MEN NNN 1 4 Package NE vr 1 5 PTE 1 5 EAN ee 1 5 Digital ANPU essu ea aia dada ata da diia ta Deia daa ia da datada de aaa da 1 5 ee Ke RE APPS er ree ner reer ren rar rer ren rr er rer ern ree rare 1 5 AIN PO E EE OOT TET OT eb dass 1 5 STEINENE O 1 6 FOWE orreee stated hth lth s ng oh hh hh hh ah hah hah hah hak had e adh s a b6 05 66 tt titi 1 6 Environmental naa AA ee E AA d0 0u dada 1 6 C FUNCIONS enn O 1 6 PECES SONES in NANA A O rere errr US 1 6 PAYSical Dimensions UNG NL 1 6 HiOI OWOFO V GV Vai eee er ee ee er ee ee re er ed ot dt detal lc ll lr ne eer 1 8 PASSION ies NN 1 8 A OS a ai an 1 9 Z Hardware IHStEGIIBRLIOIH rticrccsrtrtrcrsrcrarsrercrrrtrersesrtrsesEszesmrsessessza ssiisisisassadidii sssiaisxsifasssisssigasdasgiisasisiasiai 2 1 COMMECTING TREHI AWA Cs 60 6n gui ti n Ki n cote cm PASSE 2 2 CONNCEUNO ENEA P
11. CD Display KIERA A AAA AA EAS A 1 CONTEOL 2 A 1 VE O 1 1 EE ER EO EE Er A 1 Modbus TCP Address Mapping siii stasis vce cats ete cdecuuedcuudedededaresnaiwendds B 1 OMF Or PS 10 MOS MANN o B 1 Ooo Read Write Coils Funelions AL 5 15 dana B 1 Loox Read Only CoS RUNCUON 2 sre cuc bu r e deddaaaeeaadas B 1 J000 Read ON REG SEP FUNTONES B 2 4xxxx Read Write Registers Functions 3 6 1 ng HT K Ko K rr B 2 ON 2 ed 0 O PE TE 1 11 1 1 I EE Tce B 2 Used Network Port NUMDEES lt Aaaa ADARA Aaa ara REDARE Aaaa anaa C 1 lOMIPCOF E32 IO NEW OK Port SG Cay a c c pate ng 6n n n 20 nen eati ca reder C 1 Factory Default Settings en D 1 PINGUES and Cable WIIIHDssairiiirdriiirirrriririr tri ri zin zasa66516640686665X150X1Y0SYKEVIEYEREWVVEXYXEKEWEWIRERENT E 1 Port PIO UE DIAO ANTS A E E EE E ETE EA EE E 2 Ethenner POT PIMOUUS an a ele ekhi da dela 44184 dadedatadadedaaden E 2 DO J Ss TC TS gc a el el te soi el E se nance aha snGcchds dodanie ceded tuah cnc cate E 2 DIOGENES TET Ed E 2 por ESTEN E 3 PET TTS AT tc ntateiadubotatadadatedotadadabotedatadeladadedstedeladadadel a t wu le E 3 1 Introduction The ioMirror E3210 is a peer to peer Ethernet I O server that acts as a cable replacement solution for connecting digital input sensors to PLC controller or DCS systems Typical applications involve using a pair of ioMirror servers one on each end of the connection The following topics are c
12. IOMirror E3210 User s Manual Third Edition May 2014 www moxa com product 2014 Moxa Inc All rights reserved IOMirror E3210 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Trademarks 2014 Moxa Inc All rights reserved The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact I nformation Moxa
13. In the web console the left panel is the navigation panel and contains an expandable menu tree for navigating among the various settings and categories Click on an item in the navigation panel to jump to that page For example if you click on Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You can enter configuration changes directly on the page Click on the Submit button at the bottom of the page after making configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your changes will not be retained Submitted changes will not take effect until they are saved and the unit is restarted You may save and restart the server in one step by clicking on the Save Restart button after you submit a change If you need to make several changes before restarting you may save your changes without restarting by selecting Save Restart in the navigation panel If you restart the unit without saving your configuration you will lose all configuration changes that have been submitted 3 2 ioMirror E3210 Using the Web Console Quick Reference The following is a quick reference guide to the pages in the ioMirror s web console Details for each page are presented later in this chapter Overview Show model name serial number etc Basic Settings Set time time ser
14. OWO anae e E A E EA a e OS 2 2 Grounding NE URN ainame acre asa E E E E OAE E E 2 2 Connecting tothe NOMWOKK errien aaa EEE E A Geeks daa 2 2 Connecting thel DEV 2 2 e O AAA A AEA Aa 2 3 Stac OFr Dy Nae IE ae 2 3 Factory IDETAUIE S STUNG Sinatra 2 3 Modyo l PAET ere 2 4 3 Using the Web COHSOIE irriiriiririiiiii21i1201621112111216171206 yE5EiSand5x yEanglraviivteigtlgssdeesidiessds4des4dssidgigdsssii 3 1 NEMNE 3 2 Opening the Neb CO SOI users 3 2 NES fe CT 3 2 QUIE RRSP MO NN ae 3 3 PSN 3 3 NetWork SENSE 3 4 General SENOS EE A A aa Nae een ait 3 4 Ethernet CON ENN 3 4 OS Ar 3 5 PLENEN SEN ua 3 5 DO Channel SENI S A O dear 3 5 I MIIfT I SENO STENENE EE EEE de cae nal he anes ale han tata 3 6 SEN MENE ENE 3 7 ACCeSSIDIE IELTS ii A42 3 7 NERE NNN 3 8 L NT eee 3 8 Chone NE 3 9 Eoad Factory DEM eee 3 9 Save RNA 0091000017 3 9 4 10MirtrorAdmin SH IOEVEH HDLOO c 2272222222202222222222222270022c acta 4 1 NNN NNN NNN 4 2 MANN 4 2 Te ul de ee EE EE EE OE EE Ree 4 3 Searching Tor WO MITO SEN ES Jenin 4 3 WING CUGE inre A A A LUMP Chere rere rere rere rere ene here reer ere re ener ene ney er 4 4 ONIO CONOUG A UON aeinn b ri A SES 4 4 EMNE UDG GLC Lavere 4 5 RE 1 3 22222212 1 22 2 1 1 4 44 4 4 5 PSS EO DETSE rres an a aE E EEE E ER EATE EREE RE TREE EA aa aani 4 5 DEVERIA vi ae a A A A AA a adeciaareaaeas 4 5 BESIC FUNN SNE 4 5 COME Need T 4 6 OPNE ENN 4 7 ES 0 KN P 4 7 E
15. Total Solution for Industrial Device Networking 3 Main Menu E3210 al Overview 1 Basic Settings General Settings I O Server Settings El Network Settings li Sa GA Server Name GI General Settings 1 Ethernet Configurations Server Location E 1 O Settings DNS Server 1 255 255 255 255 6 DI Channels DNS Server 2 1255 255 255 255 DO Channels 3 ioMirror Settings ag System Management al Aceaceihla IM Cattinac Ethernet Configurations On the Ethernet Configurations page you may assign the IP address subnet mask and gateway for your ioMirror server You may also configure the IP address to be dynamically assigned by DHCP DHCP BOOTP or BOOTP Total Solution for Industrial Device Networking 3 Main Menu E3210 29 Overview Ga Basic Settings Ethernet Configurations Ethernet Parameters Eb Network Settings Tu IP Configuration Static x General Settings AA 2 EfhemetConfiaurationg P Address 122 1081983 El I O Settings Subnet Mask 255 255 255 0 gen DI Channels Gateway 0 000 C1 DO Channels G1 ioMirror Settings i Submit EX System Management Submit 3 4 ioMirror E3210 Using the Web Console I O Settings DI Channels Settings On the DI Channel Settings page you may view the status of each DI digital input channel Click a channel to modify the digital input filter 3 Total Solution for Indu
16. c 1 open Logic 0 O to 3 VDC Logic 1 10 to 30 VDC DI COM to DI 3K VDC 2 KVrms 8 points 1 COM 8 points sink type Digital Output 24 VDC nominal Max 200 mA per channel 2K VDC 2 KVrms 8 points 1 COM Over voltage protection 50 VDC Over current limit 600 mA typical Over temperature shutdown 160 C min 1 point sink type 24 VDC nominal Max 200 mA 3K VDC 2 KVrms 1 5 ioMirror E3210 Introduction Software Utilities ioMirrorAdmin for Windows Configuration Web browser ioMirrorAdmin Power Power Input 24 VDC nominal 12 min to 48 VDC max Power Consumption 3 26 W 24 VDC typical DO Power 24 VDC nominal up to 48 VDC Wiring I O cable max 14 AWG Environmental Operating Temperature 10 to 60 C Storage Temperature 40 to 85 C Altitude Up to 2000 m Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes Certifications Shock Free fall Vibration CE Class A Level 3 Criteria B FCC Part 15 CISPR EN55022 Class A UL508 EC61000 6 2 EC61000 6 4 Accessories LCD Display Kit Hot pluggable attachment for IP display DI DO status 16 x 2 character display Backlit screen 5 buttons Physical Dimensions Units mm _ EE COC Y yr Y ioMirror E3210 Introduction 121 8 ir 1 7 ioMirror E3210 Introduction Hardware Overview 24 VDC power input TB1 Power Ready Serial LEDs Reset RJ45 Ether
17. c Settings O Network Settings gt General Settings gt Ethernet Configurations O 1 O Settings gt DI Channels Settings gt DO Channel Settings O ioMirror Settings a System Management gt Accessible IP Settings gt Network Connection LCM Change Password Load Factory Default n n n Save Restart ioMirror E3210 Using the Web Console Overview Opening the Web Console Use a standard web browser such as Microsoft Internet Explorer to open the web console Simply point the browser to your ioMirror s IP address For initial configuration use the ioMirror default IP address of 192 168 127 254 The web console should appear as below Total Solution for Industrial Device Networking 3 Main Menu E3210 Overview el Basic Settings Network Settings Welcome to ioMirror Series ioMirror Ethernet I O Server Pi Model Name E3210 1 General Settings E 00000 J Ethernet Configurations Firmware Version V1 0 Build07040215 B I O Settings Ethernet IP Address 192 168 19 85 Ethernet MAC Address 00 90 e8 0d 0e 85 DI Channels 3 DO Channels a ioMirror Settings Accessible IP Settings E Network Connection E LOM T Change Password i Load Factory Default Save Restart The main page of the web console displays detailed information about your ioMirror unit including module name serial number firmware version IP address and MAC address Navigation
18. er The following topics are covered in this chapter O Connecting the Hardware gt gt gt gt Connecting the Power Grounding the Unit Connecting to the Network Connecting the I O Device Setting the IP Address gt gt gt Static or Dynamic IP Factory Default Settings Modifying IP Address ioMirror E3210 Hardware Installation Connecting the Hardware Connecting the Power Connect your 12 to 30 VDC power supply to the ioMirror s terminal block If power is properly supplied the Power LED will light up red until the system is ready Grounding the Unit Connect your grounding line to the wall mount sockets or DIN rail Connecting to the Network For initial installation connect the ioMirror to the same LAN as your host computer through an Ethernet switch or hub Alternatively you can use a straight through Ethernet cable to connect the ioMirror directly to the host computer Connecting the I O Device DI Dry Contact PIN11 DI Wet Contact 2 2 ioMirror E3210 Hardware Installation DO Pin 15 Pin 24 O O O O O O O O O O D D D oO D D O O O O 2 0 1 2 3 4 5 6 T T E Alarm Output 2 v OND Setting the IP Address Static or Dynamic IP The oMirror E3210 supports both static and dynamic IP addresses You may need to consult with your network administrator to determine how IP addresses are assigned in your network environment For a static I P envi
19. ess up or down to navigate through the different I O channels without having to go back to the previous menu Select this option to enter an IP address to ping If you get a timeout error it indicates that the unit cannot reach that IP address Otherwise the display will show the response time e ip address e ping ip Enter this submenu to display the restart now submenu Enter the restart now submenu to display the restart option Press the center button to modify this option then select enable to save changes and reboot the ioMirror server The disable option has no effect Configuration changes that are made through the LCD display kit will not take effect until the unit has been A 2 Modbus TCP Address Mappings IoMirror E3210 Modbus Mapping Oxxxx Read Write Coils Functions 1 5 15 1xxxx Read Only Coils Function 2 10004 0x0003 CH3 DI Value 0 OFF 1 ON ioMirror E3210 Modbus TCP Address Mappings 3xxxx Read Only Registers Function 4 34097 0x1000 1 word Vendor ID 0x1393 4096 34098 Ox1001 1 word Unit ID Ethernet 1 4097 34099 0x1002 1 word Product Code 0x2210 4098 38193 to 0x2000 72 word Get all DI channels CURRENT status 38264 8192 to 8283 38265 to 0x2048 48 word Get all DO channels CURRENT status 38312 8264 to 8311 38313 to 0x2078 72 word Get all DI channels POWER ON status 38384 8312 to 8383 38385 to 0x20CO0 48 word Get all DO channels POWER ON status 38432 8384
20. h event the following information is provided The log can be sorted by any of these fields e event type e event date and time 4 5 ioMirror E3210 e iOMirror source name e iOMirror source IP e joMirror destination IP System 11 ti n 03 07 07 15 2i 25 B lie Jr 18 16 10 14 z0 2a 1z Ds OG AA cam E A Log Event type On Line On Line On Line Off Line On Line On Line On Line On Line On Line On Line On Line Off Line Off Line Off Line Off Line Off Line Off Line Off Line Off Line Off Line 1 Configuration In the System menu select Settings to configure ioEventLog Alarm Listen Par Part Log Director Director C Program Files Moxa sioh rors elit log Screen Colo Event Type Cold Start Warm Start Off Line On Line Event Date Time 14122000 0 1 20 17172000 0 1 20 1 7 2000 01 20 17772000 0 1 20 1772000 01 20 1772000 0 1 20 17172000 0 1 20 17172000 0 1 20 17172000 0 1 20 17172000 0 1 20 17172000 0 1 20 1 7 2000 0 1 20 1272000 01 20 1772000 01 20 1272000 0 1 20 17172000 0 1 20 17172000 0 1 20 17172000 0 1 20 14742000 0 1 20 17172000 0 1 20 410597 JAA T Color Source Name ioMirrorAdmin and ioEventLog Source IP 192 168 19 58 192 168 19 58 192 168 19 58 192 168 19 88 192 168 19 88 192 165 19 58 192 165 13 58 192 165 19 58 192 165 19 58 192 165 19 58 132 168 15 58 192 168 19 88 192 168 19 88 192 168 1
21. ic A A Fie System Sort Help pe g lS Host 192 168 127 1 tia IO Mirror 192 168 127 253 192 168 127 253 ioMirror E3210 BDI 8D0 0 00 00 48 FF 06 34 19 4 3 ioMirror E3210 ioMirrorAdmin and ioEventLog Wiring Guide To view the ioMirror wiring guide select Wiring Guide from the Help menu E3210 Ethernet Peer to Peer O 8 Digital input and 8 Digital output System Overview Ethernet pin assignment OA OOO iT LL NNN SE TA LEA 3 RX 6 RX E3210 Wiring Example 1 Digital Input Dry Contact afal e aja E 2 o 1232 53 4 5 ES ft Dl dl Woo 1d ioMirror Configuration The ioMirror s web console can be opened within ioMirrorAdmin Select the desired unit in the left panel The unit s web console will appear in the right panel Please refer to Chapter 3 for information on using the web console 3 Hon 192 169 127 1 kj t a oHe cR 192168127253 aE gt Total Solution for industrial Device Networking Welcome to ioMirror Serias Ethernet Peer To Peer 1 0 Server Model Name E3210 C 1 0 Settings Serial Number 00053 Og iomirror Settings Firmware version V1 2 Build07121011 HG System Management Ethernet IP Address 192 168 127 253 LEM Ethernet MAC Address 00 90 e8 11 54 af 2 Change Password I Load Factory Default I Save Restart 00012 Fe ORR 4 4 ioMirror E3210 ioMirrorAdmin and ioEventLog Firmware Update The ioM
22. ing sets the channel s output status when the I O server is in an alarm state The alarm is configured on the ioMirror Settings page After changing the DO channel settings do not forget to Save Restart your system 3 5 ioMirror E3210 Using the Web Console DO Channel 0 Settings Mode DO Status 1 Current Setting DO Off L2 Power On Setting DO Off 3 Alarm Status Setting DO Off Warning Be sure to Save Restart your setting ioMirror Settings On the ioMirror Settings page you may configure how I O signals will be transmitted over Ethernet and how the alarm will operate Under ioMirror Settings Interval time determines how often I O signals will be transmitted and accepts values between 20 and 600 000 ms TCP Port no determines the network port that is used for I O signal transmission You can modify this setting as necessary to transmit signals through a firewall Time out determines how long the ioMirror will wait for a network response before it will consider the connection broken Alarm Settings The ioMirror can serve as the input module to several remote output modules simultaneously At the same time it can also serve as the output module to other remote input modules The ioMirror s alarm is designed to activate if any of these connections to other ioMirror units is broken When the alarm is activated several things happen e all DO channels are reset to their Alarm status e the alarm LED flashes
23. irror firmware can be updated through ioMirrorAdmin Select the desired unit in the left panel In the right panel select the Firmware Update tab You may obtain the latest firmware by visiting the Moxa website File System Sort Help 8 ioMirror E3210 8DI 8DO Kol Web Console a Firmware Update E amp Host 192 168 127 1 E 42 ioMiror SaR 192 168 127 253 E E3210 Firmware File Path DAFWR_E3210 41 25 Build12053012 BETA 3kp Warning 1 The firmware download may take around 2 minutes 2 Disconnecting power or network cable during the time would lead to firmware corruption Es Step 2 2 PEPPER EN RESEEESE555 Total progress i PEPE JJRRRRRRRRRR Restart System You may restart any ioMirror server over the network Right click the desired unit in the left panel and select Restart System Reset to Default You may load the factory default settings for any ioMirror server on the network Right click the desired unit in the left panel and select Reset to Default ioEventLog Basic Functions ioEventLog is installed along with ioMirrorAdmin from the Document and Software CD It is designed to help you keep a record of ioMirror status events over the network The log is stored on the Windows PC and you will need to set up your ioMirror server to send status events to your PC s IP address The following events are monitored e cold start e warm start e off line e on line For eac
24. net CN1 KOM ie A ae e iso long G aii ERE I O status LED Label 1 Removable terminal block for I O points 3 81 mm max 14 AWG TB2 Please note that the LCD display module is an optional accessory Reset Button The reset button is used to load factory defaults Use a pointed object such as a straightened paper clip or toothpick to hold the reset button down for 5 seconds The Ready LED will turn red as the factory defaults are loaded and will change to green when the operation is complete Pin Assignments Ethernet CN1 Power TB1 eal V V FG 1 8 ioMirror E3210 Introduction I O TB2 Left to right Signal arn vo pur boo bor 002 003 vos pas vos bor bo ano LED Indicators Ethernet LEDs Live 10Mbps Ethernet connection Ethernet Live 100Mbps Ethernet connection Flashing Transmitting or receiving data System LEDs PWR Red System error Green ioMirror is functioning normally Off s Power error condition exists E3210 Peer to Peer I O I O LEDs 8 Digital input 8 Digital output DI 1 to 8 Status is on DO 1 to 8 Status is off A DI has lost connection with remote output module arm Flashing DO has lost connection with remote input module DO PWR Red DO power in 1 9 2 Hardware Installation This chapter explains how to install the ioMirror E3210 peer to peer Ethernet O serv
25. ng the server go to the previous item go to the next item exit the current submenu and return to the previous menu go up one level Right enter the selected submenu go down one level enter exit editing mode An e in the upper right hand corner of the display indicates that the parameter can be modified Press the center button to modify that parameter s settings Menu Options This is the default screen Enter this submenu to display information about the specific server you are viewing e serial number lt ioMirror E3210 gt nanie server location e3210 f w ver Icm f w ver model name Enter this submenu to display information and settings for the network ethernet link mac Address ip mode Static DHCP DHCP Bootp Bootp ip Address 192 168 127 254 netmask 255 255 255 0 lt ioMirror E3210 gt network gateway 0 0 0 0 dns Server 1 255 255 255 255 dns Server 2 255 255 255 255 ioMirror E3210 LCD Display Kit Display Explanation Actions lt ioMirror E3210 gt mirror lt ioMirror E3210 gt i o setting lt ioMirror E3210 gt ping lt ioMirror E3210 gt save restart ATTENTION restarted Enter this submenu to view and set the IP address of the remote output module This is only for ioMirrors that are operating in Module to Module mode e ME SMIP Enter this submenu to view I O channel status Here are examples of settings that you might see e di 00 on e di 07 0 Pr
26. ork is reconnected without rebooting Modbus TCP support for SCADA systems V v Y WV 1 3 ioMirror E3210 Introduction Infrastructure Examples Ethernet Network Existing Ethernet Without Controller Input Moudule HETT HUH Up to 8 Inputs Up to 8 Outputs Fiber Optic Network er ere ii 4 Output Module AL Redundant Module 1 Fiber Line 2 10 100 MB Ethernet Wireless LAN PN gt R EDE Module Output Module Wireless LAN 1 4 ioMirror E3210 Introduction Package Checklist Standard Accessories e joMirror E3210 peer to peer Ethernet I O server e Document and Software CD Optional Accessories e LDP1602 ioMirror LCD display kit NOTE Notify your sales representative if any of the above items are missing or damaged Specifications LAN Interface Protocols Protection IP Address Digital Input Channels I O Mode Dry Contact Wet Contact Isolation Common Type Digital Output Channels I O Mode On state Voltage Output Current Rating Optical I solation Common Type Protection Alarm Port Channels On state Voltage Output Current Rating Optical I solation 10 100BaseTx with MDI MDIX RJ 45 DHCP BootP TCP UDP IP ICMP ARP HTTP SNTP ioMirror Modbus TCP up to 3 sockets 1 5 KV magnetic isolation Fixed dynamic DHCP Default 192 168 127 254 8 points source type dry contact or wet contact Digital Input Logic 0 close to GND Logi
27. overed in this chapter O Welcome O Features O Infrastructure Examples gt Ethernet Network gt Fiber Optic Network gt Wireless LAN O Package Checklist O Specifications LAN Digital Input Digital Output Alarm Port Software Power Environmental V v V v Y V V WV Certifications gt Accessories O Physical Dimensions Units mm O Hardware Overview gt Pin Assignments gt LED Indicators ioMirror E3210 Introduction Welcome The ioMirror E3210 is a cable replacement solution that connects digital input signals to digital outputs over an IP network It is equipped with 8 digital inputs 8 digital outputs and a 10 100Mbps Ethernet interface A pair of ioMirror servers can connect remote sensor signals to a PLC controller DCS systems or a display device over Ethernet eliminating the need to install additional signal wires Up to 8 digital input signals can be connected from one ioMirror to another with only 20 ms signal latency over a local area network A E Mo mil ur ii tto Ethernet tt oh Digital output igital input tt Digital output Industrial Business Automation Applications The ioMirror is a fast and easy way to connect input and output signals over IP networks It is ideal for non mission critical applications such as remote monitoring Maximum transmission distance can be achieved without programming and without a separate controller Potential applications include the following
28. ronment you can enter a specific IP address using ioMirrorAdmin or the web console In a dynamic IP environment BOOTP or DHCP you can use ioMirrorAdmin or the web console to specify the DHCP DHCP BOOTP or BOOTP server that will assign the ioMirror s IP address Factory Default Settings The factory default network settings are as follows e IP address 192 168 127 254 e Netmask 255 255 255 0 e Gateway None 2 3 ioMirror E3210 Hardware Installation Modifying IP Address There are several ways to modify the ioMirror s IP address ioMirrorAdmin is a Windows utility that can be used locally or on the network to configure the unit and upgrade the firmware Please refer to Chapter 4 for instructions on using ioMirrorAdmin The web console is a configuration tool that is opened using a standard web browser through a localor network connection Please refer to Chapter 3 for instructions on opening and using the web console The LCD display kit is an optional accessory that can be used on site for basic monitoring and configuration Please refer to Appendix A for instructions on using the LCD display kit 2 4 3 Using the Web Console The ioMirror can be configured using a standard web browser over a direct or network connection This chapter explains how to open and use the web console The following topics are covered in this chapter O Overview gt Opening the Web Console gt Navigation gt Quick Reference O Basi
29. s will show Attached and the firmware details will be displayed E Main Menu 3210 i LCM Module Information gm Overview a Basic Settings As i LCM Module ee LCM Module Not Found i re General Settings Firmware Version E Ethernet Configurations Firmware Release Date ci 1 0 Settings DI Channels mi DO Channels a ioMirror Settings 53 System Management a Accessible IP Settings G Network Connection 3 Change Password A 3 8 3 gt Total Solution for Industrial Device Networking ioMirror E3210 Using the Web Console Change Password On the Change Password page you may add or change the password Total Solution for Industrial Device Networking 3 Main Menu 3210 ae Overview ra Basic Settings E Network Settings gm General Settings Change Password Password Old password Ethernet Configurations New password E I O Settings Retype password a DI Channels DO Channels CI iomirror Settings as 2 Load Factory Default On the Load Factory Default page you may reset the ioMirror back to its factory default settings Total Solution for Industrial Device Networking amp Main Menu E3210 i Load Factory Default E Overview a Basic Settings This function will reset I O Server settings to their factory default values Be aware that previous settings will be Network Settings lost
30. strial Device Networking SI Main Menu E3210 al Overview 1 Basic Settings DI Channel Settings E DI Channel Mode Status Filter Network snug BEGG DI Off 0 5 ms al General Settings DI 01 DI Off 0 5 ms E Ethernet Configurations DI 02 DI Off 0 5 ms og DI Channels DI 04 DI off 0 5 ms E DI 05 DI Off 0 5 ms I DO Channels DI 06 DI Off 0 5 ms 9 ioMirror Settings DI 07 DI Off 0 5 ms La Cuctam Mananamant The maximum digital input filter value is 65535 DI Channel 0 Settings Mode Filter DI El Note Filter unit 0 5ms range 1 65535 Warning Be sure to Save Restart your setting DO Channel Settings On the DO Channel Settings page you may configure each DO digital output channel by clicking on the channel 3 gt Total Solution for Industrial Device Networking Main Menu E3210 fan Overview an Basic Settings DO Channel Settings E DO Channel Mode Status XS Network Settings 66 06 DO Off i el General Settings DO 01 DO Off QJ Ethernet Configurations DO 02 DO Off E 1 0 Settings DO 03 DO Off 3 DI Channels DO 04 DO off EN DO 05 DO Off 9 DO Channels DO 06 Off I ioMirror Settings DO 07 DO Off The Current Setting sets the channel s current output status in order to test the DO connection The Power On Setting sets the channel s output status when the I O server is first powered The Alarm Status Sett
31. ventLog Basic Functions Yy Configuration Yy Opening Log Files Yy Clearing the Log ioMirror E3210 ioMirrorAdmin and ioEventLog Overview Two Windows utilities are provided with the ioMirror E3210 e joMirrorAdmin allows you to manage your unit over the network You can configure the unit upgrade the firmware or refer to the unit s wiring guide oEventLog receives and stores error messages from ioMirror units on the network Installation To install ioMirrorAdmin and ioEventLog run SETUP EXE from the Document and Software CD The installation wizard will guide you through the installation process When the installation process is complete you can open either utility through the Windows Start menu File System Sort Help 2 8 og O Mirror EE 192 168 127 253 HH Module Connection 192 168 127 253 ioMirror E3210 BDI 8D0 Refresh 0 00 00 48 TF 06 34 19 System Log Help Event Date Time On Line On Line 1 1 2000 0 1 20 Off Line 1 1 2000 0 1 20 On Line 1 1 2000 0 1 20 On Line 1 1 2000 0 1 20 On Line 14122000 0 1 20 On Line 1 1 2000 0 1 20 On Line 1 1 2000 0 1 20 On Line 14122000 0 1 20 On Line 1 1 2000 0 1 20 Off Line 1 1 2000 0 1 20 Off Line 14122000 0 1 20 Off Line 14122000 0 1 20 Off Line 11 2000 0 1 20 Off Line 1 1 2000 0 1 20 Off Line 14122000 0 1 20 Off Line 14172000 0 1 20 Off Line 1 1 2000 0 1 20 Off Line 1 1 2000 0 1 20 FAA 4747 90
32. ver Network Settings General Settings Set name location DNS Ethernet Configurations Set IP address netmask gateway I O Settings DI Channels Configure digital input channels DO Channels Configure digital output channels ioMirror Settings Configure channel module mapping alarm system System Management Accessible I P Settings Filter access by IP address Network Connection Show TCP connections from different hosts LCM Show LCM status Change Password Set password Load Factory Default Restore factory default settings Save Restart Save all changes and reboot Basic Settings On the Basic Settings page you may set the system time or provide the IP address of a time server for time synchronization 3 Total Solution for Industrial Device Networking 153 Main Menu E3210 ag Overview Y Basic Settinas Basic Settings JENS AS Time Settings Network Settings 5 z pm Gc er Time zone 24 hour GMT Greenwich Mean Time Dublin Edinburgh Lisbon London MEN eneral Settings a 8 Y end comunica Local time 2006 03 4129 20 47 40 Modify 3 I O Settings System Elapsed Time 2 22 59 i pi Channele Time server 3 DO Channels 4 ioMirror Settings FL Cuctam Mananamant 3 3 ioMirror E3210 Using the Web Console Network Settings General Settings On the General Settings page you may assign a server name and location to assist you in differentiating between different I O servers
33. with general input output signals carried by a pair of ioMirror I O servers Wiring plans are now easier than ever e No programming and no separate PLC or PC controller A separate PLC or PC controller is not required for ioMirror operation No ladder or C programming is required either All configuration can be done through ioMirrorAdmin or through the web console e Local sensor signals duplicated to up to sixteen locations Each digital input signal can be mapped to two IP destinations For example you may monitor the eight tank level signals by up to sixteen display panels at the same time Easy and flexible installation The Windows utility for installation and configuration is easy to use For basic module to module configuration you may simply assign the destination IP address for mapping For advanced configuration you can easily specify the mapping destination for each channel e Easy troubleshooting tools ioMirror connections are easily monitored and managed There are many tools and features that can alert you to a problem or show you the status of a connection gt Optional LCD display for local IP configuration gt Instant error status with special built in alarm port for 24 VDC alarm devices such as buzzer or LED tower Alarm and event log that records each connection and disconnection Windows utility that displays channel mappings and status for every oMirror server on the network Automatic recovery within seconds when netw