Home
Precautions for replacing QnUD(E)(H)CPU with QnUDVCPU
Contents
1. Issue No FA A 0147 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU Q04UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU Page 2 7 1 PRECAUTIONS FOR REPLACEMENT 1 System configuration Ooo em Precaution O Replacement method RS 232 port Applicable products and software Multiple CPU system Current consumption There is no RS 232 port e A programming tool that was available for the QnUD E H CPU can no longer be used or needs to be upgraded The use of GX Developer is not supported in the system after replacement e Some GOTs and intelligent function modules that were available for the QnUD E H CPU can no longer be used or need to be upgraded Scan time is shortened in the High speed Universal model QCPU because operations are performed at higher speed When used in a multiple CPU system the High speed Universal model QCPU accesses to the control modules frequently As a result the processing time in other CPU modules may increase The current consumption increases Use a USB or Ethernet port To communicate with an RS 232 interface use the QJ71C24N R2 in the system e Upgrade the version of GX Works2 to the one compatible with the QnUDVCPU e Replace the GOT and intelligent function modules to those compatible with the QnUDVCPU Check the processing timings of other CPU modules and adjust the access fr
2. File transfer function FTP server from the password registration function to the file password 32 function For this reason the keyword set subcommand that sets displays clears the file access password is no longer supported Use the FTP commands passwd rd and passwd wr that set display clear the read write passwords of the file password 32 function 1 This applies when the QnUDE H CPU is replaced with the High speed Universal model QCPU 6 Functions QnUCPU User s Manual Communication via Built in Ethernet Port Replacement method Security function Latch data backup to standard ROM Battery life prolonging function The security function that limits accesses to the files in the CPU module has been enhanced from the password registration function to the file password 32 function If an extended SRAM cassette is used and the memory capacity of the standard RAM drive 3 is larger than that of the standard ROM data cannot be backed up using this function The battery life prolonging function is no longer supported Without the use of the function the battery life is as same as that of the QNUD E H CPU Use the file password 32 function instead of the password registration function Deselect the Backup all files in the internal of standard RAM checkbox in the PLC System tab of the PLC parameter dialog box The switch setting parameters are ignored and the following operatio
3. in an SD memory card or the FREAD FWRITE instructions e Store the file in the standard RAM e If the size of the sampling trace file exceeds the standard RAM capacity consider the use of an extended SRAM cassette Specify an SD memory card as a backup destination or restoration source a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Section 3 25 in the QnUCPU User s Manual Function Explanation Program Fundamentals Section 6 2 in the QnUCPU User s Manual Function Explanation Program Fundamentals Section 4 7 1 in the QnUCPU User s Manual Function Explanation Program Fundamentals e Section 3 25 in the QnUCPU User s Manual Function Explanation rogram Fundamentals e MELSEC Q L rogramming Manual Common Instruction Section 3 14 2 in the QnUCPU User s Manual Function Explanation Program Fundamentals Section 3 31 in the QnUCPU User s Manual Function Explanation Program Fundamentals TECHNICAL BULLETIN Issue No FA A 0147 Title Precautions for replacing QnNUD E H CPU with QnNUDVCPU Date of Issue February 2013 Page 5 7 Relevant Models QO3UDVCPU Q04UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU 5 Built in Ethernet port communications Ooo o oem Precaution O Replacement method The security function has been enhanced
4. TECHNICAL BULLETIN Issue No FA A 0147 Page 1 7 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU Q04UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU Thank you for your continued support of Mitsubishi programmable controllers MELSEC Q series This bulletin provides precautions for replacing the QnUD E H CPU with QnUDVCPU Note that the reference manuals or the references described in this bulletin are information as of February 2013 GENERIC TERMS Generic term A generic term for the QO3UDVCPU Q04UDVCPU Q06UDVCPU QI3UDVCPU and High speed Universal model QCPU Q26UDVCPU A generic term for the QO3UDCPU Q04UDHCPU Q06UDHCPU QIOUDHCPU QI3UDHCPU 1UD H CPU asian Q20UDHCPU and Q26UDHCPU A generic term for the QO3UDECPU Q04UDEHCPU QO6UDEHCPU QIOUDEHCPU QnUDE H CPU Q13UDEHCPU Q20UDEHCPU Q26UDEHCPU QS0UDEHCPU and Q100UDEHCPU A generic term for the QO3UDCPU Q03UDECPU Q04UDHCPU Q04UDEHCPU QO06UDHCPU QnUD E H CPU QO6UDEHCPU Q10UDHCPU Q10UDEHCPU Q13UDHCPU Q13UDEHCPU Q20UDHCPU Q20UDEHCPU Q26UDHCPU Q26UDEHCPU Q50UDEHCPU and Q100UDEHCPU A generic term for the QO3UDVCPU Q04UDVCPU Q06UDVCPU QI3UDVCPU and Q26UDVCPU QnUDVCPU aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN
5. eed Universal model QCPU does not operate normally when the Web server module on which GX RemoteService I is installed is used 2 The High speed Universal model QCPU does not operate normally when an incompatible module version is used b Personal computer boards Dedicated software package version CC Link IE Field Network interface board Q81BD J71GF11 T2 1 03D or later e Q81BD J71GP21 SX e Q81BD J71GP21S SX CC Link IE Controller Network interface board 1 15R or later e Q80BD J71GP21 SX e Q80BD J71GP21S SX e Q80BD J71LP21 25 SI QSI H PCF optical S J71LP21S 25 MELSECNET H cable i Q81BDJ71LP21 25 o J71LP21 25 25B or later interface board GI optical cable Q80BD J71LP21G Coaxial cable Q80BD J71BR11 e Q80BD J61BT11N CC Link system master local interface board 1 12N or later e Q81BD J61BT11 1 No restrictions on the board itself c GOT GT Works3 OS version e GT160 0 e GTISO O GOT1000 e GT140 0 1 64S or later GT110 O0 GT100 O 1 No restrictions on GOT itself a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No FA A 0147 Page 7 7 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU QO4UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU d Networ
6. equency of the High speed Universal model QCPU using timers or the constant scan function Select a power supply module according to the total current consumption in the system 1 This applies when the QnUD H CPU is replaced with the High speed Universal model QCPU Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Chapter 2 QCPU User s Manual Multiple CPU System QCPU User s Manual Hardware Design Maintenance and Inspection TECHNICAL BULLETIN Issue No FA A 0147 Page 3 7 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU QO4UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU 2 Program Ooo o oeme Precaution O Replacement method If index modifications mentioned on the instructions left are frequently used in the program the program size may exceed the storage capacity of the replaced CPU module After the program controller type is changed check the program size using the confirm memory size function If the The number of steps increases by one program size exceeds the storage capacity when take the following actions or change the e Index modification is performed F j MELSEC Q L CPU module to that with larger program Number of steps e A leading or trailing edge instruction is Programmin
7. function with memory card A memory card SRAM card ATA card or Flash card cannot be specified as a transfer source Specify an SD memory card as a transfer source Section 2 11 in the QnUCPU User s Manual Function Explanation Program Fundamentals A device comment file cannot be stored in Store the file in the standard RAM an SRAM card A device comment file cannot be stored in Store the file in an SD memory card an ATA card nor Flash card An initial device value file cannot be stored in an SRAM card An initial device value file cannot be Store the file in an SD memory card stored in an ATA card nor Flash card A local device file cannot be stored in an SRAM card A file register file cannot be stored in an SRAM card A file register file cannot be stored in a Flash card Sequence programs only can read file register data in a Flash card A sampling trace file cannot be stored in an SRAM card A memory card cannot be specified as a backup destination or restoration source Store the file in the standard RAM or standard ROM e Store the file in the standard RAM e If the size of the local device file exceeds the standard RAM capacity consider the use of an extended SRAM cassette e Store the file in the standard RAM e If the size of the file register file exceeds the standard RAM capacity consider the use of an extended SRAM cassette Use the initial device value file
8. g Manual memory used as Common Instruction e Move parameters and device comments to the standard ROM Reduce the reserved area for online e Bit devices are used as word data by specifying digits using K1 K2 K3 K5 K6 or K7 or by specifying a device change number of other than multiples of 16 ses the le repister extended data register and extended link register within 64K words because the number of steps decreases by one when used in that way 3 Parameter size Replacement method PSI e Delete unnecessary files and free some The parameter size increases because the space Parameter size built in Ethernet port setting parameters are added e Move the parameter file to another memory area 1 This applies when the QnUD H CPU is replaced with the High speed Universal model QCPU a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No FA A 0147 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU Q04UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU Page 4 7 4 Drive and file P oeme Precaution S O Replacement method Boot file setting Device comment Initial device value Local device File register Sampling trace CPU module change
9. k modules and serial communication modules e QJ71LP21 25 e QJ71LP21S 25 MELSECNET H module e QJ71LP21G Some restrictions depending on use conditions e QJ71LP21GE e QJ71BR11 C24N Serial communication module C24N R2 Serial number first five digits 10042 or later C24N R4 1 The serial number first five digits of the MELSECNET H module must be 10042 or later if all conditions 1 to 4 described below are satisfied 1 A multiple CPU system including Built in Ethernet port QCPU is configured 2 A programming tool or GOT is connected to an Ethernet port of Built in Ethernet port QCPU 3 A programming tool or GOT accesses the CPU module on another station via the MELSECNET H module controlled by another CPU 4 The access target on another station is A QnA series CPU module 2 CPU modules that can configure a multiple CPU system with the Universal model QCPU CPU modules that can configure a multiple CPU system with the Universal model QCPU are shown below CPU module Applicable version e Q172DCPU Q173DCPU i QI72DCPU S1 Use only the multiple CPU high speed Motion CPU No restrictions main base unit Q3LDB as a main base e Q173DCPU S1 e Q172DSCPU e Q173DSCPU PC CPU module ppc cpussymsy wa o O e Q06CCPU V N A e Q06CCPU V B C Controller module e QI2DCCPU V Serial number first five digits e Q24DHCCPU V 14122 or later e Q02CPU QO2ZHCPU High Performance model QCPU QO6HCPU Function ver
10. ns are performed e Data held by the battery are not cleared nor deleted e The bits b0 and b1 of SD119 Battery life prolonging factor are fixed to 0 Section 3 19 in the QnUCPU User s Manual Function Explanation Program Fundamentals Section 3 29 4 in the QnUCPU User s Manual Function Explanation Program Fundamentals e Section 3 26 in the QnUCPU User s Manual Function Explanation Program Fundamentals e QCPU User s Manual Hardware Design Maintenance and Inspection a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN TECHNICAL BULLETIN Issue No FA A 0147 Page 6 7 Title Precautions for replacing QnUD E H CPU with QnUDVCPU Date of Issue February 2013 Relevant Models QO3UDVCPU QO4UDVCPU QO6UDVCPU Q13UDVCPU Q26UDVCPU 2 APPLICABLE PRODUCTS AND SOFTWARE 1 Products need to be replaced for the compatibility with the High speed Universal model QCPU The following tables show products need to be replaced for the compatibility with the High speed Universal model QCPU As for devices not listed in the tables below replacement is not required a Communication modules Web server module QJ71WS96 14122 or later MES interface module QJ71MES96 14122 or later High speed data logger module QD81DL96 14122 or later 1 The High sp
11. sion B or later e QI2HCPU e Q25HCPU e Q02PHCPU e Q06PHCPU mp Process CPU No restrictions e QI2PHCPU e Q25PHCPU unit REVISIONS Version Print Date Revision February 2013 First edition aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN