Home

Product Manual

image

Contents

1. Art 2301N 4 Entrances Switch DESCRIPTION This unit is required for systems with 2 or more entrances 4 maximum The Art 2301N has 4 inputs IN1 IN4 each with adjustable amplification L low M medium and H high to compensate for different door station distances The AUX input enables a second 2301N device to be connected to expand the system up to 8 entrances When connecting 2x2301N the polarity of the bus between the Art 2301N s must be observed When connect ing 2x2301N s the BUS output of the first exchanger must be linked to the AUX input of the second exchanger and then onto the apartments The polari ties are not relevant if there is only one 2301N The power supply inputs are PS1and PS2 The Art 2321 P with its jumper set to V2 should be used For systems with up to 4 entrances and 50 video hones only one power supply is required connected to PS1 For larger systems connect a power supply to each of the two inputs PS1 amp PS2 When 2x2301N the 2x2321 P power supplies only connect to the 2301N at which the AUX connection is used The one supplying the apart ments CONNECTION TERMINALS AND JUMPERS Terminal Jumper Description a gt BUS Output observe the polarities only when linked to the AUX input of a second 2301N AUX Auxiliary BUS input to carr
2. 20 FOUR WAY DISTRIBUTION Che se 20 RI I TT 21 TWO WAY PASSIVE DISTRIBUTION BOX 55i E iaia 21 23 nome T 22 BUS BOOSTER AND VIDEO SIGNALANPLIFIER ii EM E 22 IPA feel 23 ENTRANCES EXCHANGER FOR VX2300 DIGITAL SYSTEMS leali 23 ART 2305 24 EXTENSION RELAY FOR VX2300 DIGITAL SYSTEMS 21 24 ART 2 380 P 25 INTERFACE 2 WIRE TO AUDIO a taba ase o ceste aaa ilaele 25 ART 2321 2321 P emm 27 POWERSUPPLES 2 2 lilla E O E elba 27 Yl Te 2S 22 e 28 POWER SUPPLY CONVERTER FROM BUS LINE TO 12 lilla ii ile ile ii ii oad lil i il 28 GENERAL DIRECTIONS FOR INSTALLATION 29 NVNVIDEX Two Wire Videokit ESVK Series Art 4333 Speaker unit with built in camera 5S A h O I Balance E O f 27 tor Ros O NA CE O 0 VN 96
3. FQ POLO Art 4333 1 4333 1 color BUTTONS LAYOUT Art 4333 1 4333 1 color Art 4333 1D 4333 1D color PrtCode ESVK_ENG_1 6 doc Pag 4 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series FRONT LEDS SIGNALLING DESCRIPTION Description When illuminated indicates that it is not possible to make a call because a call or a conversation is in progress from the out door station from which you are calling or from another outdoor station on systems with multiple entrances The LED will be off when the system is in stand by If illuminated indicates that the call from the outdoor station is in progress The LED will switch OFF when the call is an swered or after the programmed number of rings If illuminated indicates that it is possible to speak because the call has been answered The LED will switch OFF at the end of a conversation or at the end of the conversation time PROGRAMMING The programming consists of the following settings Unit ID 1 8 Door Opening Time 3 or 6 seconds Conversation Time 1 or 2 minutes The settings are carried out trough the 6 way dip switch reference j on figure 2 accessible from the rear side of the module The switch 6 is not used SIGNALS ON SYSTEM CONNECTION TERMINALS locally and not from the BUS To use the electric lock with capacitor discharge make a short between and
4. orr orr on oF o fo _ oF Orr o or on o fo fo 0 Si Dee a LU Pe E HH E i ne The table above shows how to set the address of the device Considering that ON 1 and OFF 0 multiply each digit for the relevant decimal weight then sum the values obtained to get the address E g as highlighted in the table OFF ON OFF OFF ON in binary is equal to 0100101 then multiplying each digit for the relevant decimal weight you obtain the address that is 37 Note The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127 SW2 PRIVACY DURATION TIME SW2 PRIVACY DURATION TIME O Privacy Mode Privacy Duration switch 1 switches 2 3 NE cs e _ ee ed A The privacy duration time is set by switches 2 and 3 After the privacy service is en OFF abled it is disable when the set time expires or the relevant button is pressed again TZ dii No privacy time expiration the privacy service is enabled or disabled only by the ee eo e relevant button SI a The Priv terminal works as an open collector output to signal the status of the privacy service When the service is enabled the Priv output shorts to ground This mode must be set when the Art 2380 is connected in parallel with the same address to one or more inter coms videophones Make a link between terminals Priv and 2 ON PrtCode ESVK 1 6 Pag
5. ideoki Easy V 2 AD SP 2 Wire Videokit O S N 62 si O LLI Index DI O 3 WAR TG 33 ana ARR RRARRASA SERE RSRARRRARSARR ERRARE ERAS siete 4 SPEAKER UNIT WITH BUILTIN CAMERA Scc tata ih tiet haic oro ie oret hail piani 4 ART PL a caw beedstenaecdeeecuudussusasduenwcdeddaeseuedwensdunddsweunsdlemedsuddstasneeeuasedudssseweesdeeeseuddele sucdseecuudessscuadseuee 6 WHICH X 6 PART u rH em 7 DIGITAL INTERCOM FOR VX2300 2 WIRE SYSTEM 7 canale reati 9 DIGITAL VIDEOPHONE FORVX2300 2 WIRESYSTEMN lil 9 qm o m 12 HANDS FREE VIDEOMONITOR FOR 2 00 scd 12 ART S18B 16 HANDS FREE INTERCOM FOR VX 2300 5 iacit 16 ARTS T oaa a LTD CCELI
6. After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on Art 2321 IRA 5 BALANCE e nun 123456 Art 4333 1D _ _ Push to Exit PAR 12Vac DO CESVK 2IECLIPSE CESVK 2SIECLIPSE Two way Easy Videokit Titolo Data modifica CESVK 2 ECLIPSE CESVK 2S ECLIPSE Easy Videokit bifamiliare 18 07 2008 Videx Electronics S p A Nees VX Via del Lavoro 1 63020 Monte Giberto AP Dari Marco Ron GONI Phone 39 0734 631669 Fax 39 0734 631669 Note pe esvk008 dwa PrtCode ESVK_ENG_1 6 doc Pag 33 44 25 11 2009 Rev 1 6 www videx it info videx it CESVK ESVK 1 WITH VIDEO DISTRIBUTORS ART 318 317 BUTTON EXPANSION MODULE ART 125 AND ADDITIONAL VIDEOPHONES To videophones 6 and 7 Ai videocitofoni 6 e 7 ck SW3 OOO 1234 ON SW3 SW2 W123 4 1 23 4 ON ON sw2 OOOO 41234 ON Art 3980 Art 3980 c 2 Y Se me SWI SWI 12345678 2 00000 OU U U U U L 12345678 ON 2 DOE Y Ll Extension N 1 Videophone N 5 Extension N 1 2 Q 0 2 Di Videophone N 4 Local Bell Local Bell L Art 3381 CO cO CO O C1 A C5 N SW2 2 gt e gt 2 e gt gt Di VN HOOT 1234 8123 4 ese SW3 1234567
7. O O O O O 0 O O O 0 00 O 0 0 0 oOo O 000000060 00000000 i s 1 O o o O O O O O O 0 0 0 00 0 0 00 0 0 O O O O 0 0 0 O O 0 0 0 O O 0 o 0 O O O O O O O 0 0 0 000 0 0 0 0 O O O O O 0 0 000 0000000 0 DESCRIPTION PUSH BUTTONS LEDS AND CONTROLS FIG 1 Bus Relay Button to Activate bus relay board Art 2305 To activate a bus relay press as many times as the address value of the relay Answer button On an incoming call operation of this button allows the user to answer and converse with the visitor LED 2 will illumi nate Camera recall button Press as many times as the DEVICE N of the door station to switch on Switch off button With the system switched on momentary operation of the button will switch the unit off The intercom will also auto matically switch off after a time delay if the button is not pressed LED 2 will switch off Simplex button Pressing and holding the button for more than 3 seconds will switch the intercom into SIMPLEX speech mode Press and hold the button to speak to the caller LED 2 will flash rapidly release the button to listen LED 2 will flash slowly If the button is not pressed for 10 seconds the intercom will switch off The intercom will revert to duplex speech when another call is made Privacy on off button If the unit is switched on press and keep pressed this button for more than 3 seconds to enable disable the service The relative LED W
8. C then connect the electric lock between terminals and GND UNIT SPECIFICATION Housing Mounting One 4000 Series Module 4000 Series Modular System Push Buttons Yes from 0 to 2 call buttons according to the model Programming Yes carried out by the 6 way dip switch located on the rear of the module Controls Microphone and Loudspeaker volume trimmers plus balance trimmer Front plate Finishes Mirror stainless steel standard and Anodized aluminium add a after the product code Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK ENG 1 6 Pag 5 44 25 11 2009 Rev 1 6 VXIVIDEX
9. all other settings are carried out on the two dip switch banks SW1 SW3 on the rear side of the video monitor The BUS termination depends on the position of JP1 on the con nection board Except for when programming the number of rings it is necessary to temporarily remove the power supply from the unit after making pro gramming changes NUMBER OF RINGS PRIVACY DURATION AND MELODY SELECTION First of all make a recall to switch on the unit then proceed with the programming operation To alter the number of rings and select the melody the in tercom must be in program mode This is achieved by pressing the two following buttons at the same time left button of the volume control and the right button of the call tone volume control see Fig 1 When the programming mode is entered LED 1 Fig 1 starts flashing This will automatically reset after 20 seconds of idle time Number of rings When in the programming mode press and hold the button LED 1 will stop flashing and LED 3 Fig 1 will start to flash showing the number of rings each flash 1 ring i e 6 flashes 6 rings Once the value of rings has been reached release the button Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Privacy duration When in the programming mode press and hold the KK button LED 1 will stop flashing and LED 3 Fig 1 will start to flash showing the number
10. 0191 224 1559 Greece office VIDEX HELLAS Electronics 48 Filolaou Str 11633 Athens Phone 30 210 7521028 7521998 Fax 30 210 7560712 www videx gr e mail videx videx gr Danish office VIDEX DANMARK Hammershusgade 15 DK 2100 Copenhagen Phone 45 39 29 80 00 Fax 45 39 27 77 75 www Vvidex cdk
11. Programming Yes carried out by the dip switches inside the intercom Controls Call tone volume and privacy ON OFF switch Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all l prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribuito member states of the EU with no restrictions liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK ENG 1 6 Pag 8 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 3381 Digital videophone for VX2300 2 Wire System 00000 00000 e 00000 e 00000 se 00000 00000 DOOR OPEN 00000 00000 DESCRIPTION Intelligent videophone with 4 flat screen B amp W monitor with door open and camera recall push buttons bus relay enable button service button pri va
12. SPECIFICATION Housing Mounting 9 Module A Type DIN box Art 2321 15 Module A Type DIN box Art 2321 P DIN Bar or directly to the wall Push Buttons N A Programming N A Controls Voltage amplification 3 levels Power Supply 230Vac Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC EMC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 27 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 2322 Power supply converter from BUS line to 12 Vdc DESCRIPTION When this unit is connected to the BUS line it generates a 12Vdc 100mA power source This unit can be used to supply peripherals such as the Art 4800 without the need for an additional power supply Pl
13. Title Titolo Notes e Videx Electronics S p A Via del Lavoro 1 63020 Monte Giberto AP Phone 39 0734 631669 Fax 39 0734 631669 Note www videx it info videx it PrtCode ESVK ENG 1 6 Pag 30 44 12345678 1123411234 ON Due eee ON Extension N Videophone N 1 SW3 SW2 SWI1 Art 2321 BUS 123456 Push to Exit 25 11 2009 Local Bell N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on IRA BALANCE i 12Vac EL SE ine LIE 08 04 2009 Autore Marco Rongoni esvk001 dwa Rev 1 6 CESVK 1 ECLIPSE ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT Be Art 5488 W123 4 01 23 4 ON Extension N Videophone N 1 N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is
14. 25 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Switches Status Intercommunication Mode Extension 3 2 1 switch 1 switches 2 3 Intercommunication allowed between videophones same unit address inside the HC same flat To call an extension pick up the handset then press the door open button n valu 4 OFF as many times as the extension value is Eg extension 2 two times 3 three times OFF etc If there are more videophones intercoms connected in parallel one at least must be set with switches 2 and 3 to OFF Intercommunication allowed between videophones different unit address inside dif ferent flats To call an extension pick up the handset then press the door open but ton as many times as the address value is Eg extension 10 ten times 12 twelve times etc SIGNALS ON CONNECTION TERMINALS Signal Description LEM BUS connection terminals Speech line in Speech line out Speech ground Call output GND Ground 5 Active low input door open command Auxiliary active low input 2 When active 0V switches the status of privacy service Auxiliary active low input 1 When active 0V the relay with address 1 of the Art 2305 if installed in the system will activate 12Vout 12Vdc Output With SW2 4 OFF it works as an open collector output that signals the privacy service status Internal link to ground when the privacy Priv service is active With SW2 5 ON required se
15. 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 20 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 31 8 Two way passive distribution box OY YY BUS BUS OUT1 OUT2 Art 318 BL BUS BUS Close IN OUT Open DESCRIPTION The unit distributes the bus signal to 2 outputs linked to videophones or intercoms It is a passive distributor so there is no possibility to adjust the video amplification The device is suitable for small systems with a maximum distance between door panel and the last monitor of 70 metres CONNECTION TERMINALS AND JUMPERS Terminal Jumper Description BUS IN Bus input terminals BUS OUT Bus output terminals to next distrbutor BUS OUT 1 Videophone Intercom bus output 1 BUS OUT 2 Videophone Intercom bus output 2 BL Close Open bus output jumper If the distributor is the last move to close otherwise leave open SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push Buttons N A Programming N A Controls N A Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 2
16. Art 125 Connect to PTE terminal of Art 4333 Collegare al morsetto PTE dell Art 4333 Red Rosso Connect to 1C terminal of Art 4842 4843 4844 or 4845 Collegare al morsetto 1C dell Art 4842 4843 4844 o 4845 Connect to terminal 1 of the button expansion module Collegare al morsetto 1 del modulo d espansione pulsantiera Connect to terminal 2 of the button expansion module Collegare al morsetto 2 del modulo d espansione pulsantiera Connect to terminal 3 of the button expansion module Collegare al morsetto 3 del modulo d espansione pulsantiera Connect to terminal 4 of the button expansion module Collegare al morsetto 4 del modulo d espansione pulsantiera Connect to terminal 5 of the button expansion module Collegare al morsetto 5 del modulo d espansione pulsantiera DESCRIPTION This module must be used in combination with speaker units Art 4333 with firmware release 2 0 or higher The module in combination with standard 4000 series button expansion modules Art 4842 4843 4844 and 4845 allows to add up to 5 call buttons to the call buttons built in the speaker unit to reach a maximum of 7 call buttons To supply the LED of the button expansion modules make the connection as shown in figure 1 UNIT SPECIFICATION Housing Mounting 5 resistors module fix to button expansion module Push Buttons N A Programming N A Controls N A Power Supply N A Working Temperature 10 50 C CUSTOMER SUPPORT INF
17. BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all l prodotto marchiato CE a dimostrazione della sua conformit pu essere distribuito member states of the EU with no restrictions liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 11 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 5488 Hands Free Videomonitor for VX2300 o o Oo 0 0 o Oo o 0 o 0 o O 0 o o n 9 9 DESCRIPTION An intelligent Hands free surface or flush mounting video monitor employing a colour 3 5 active matrix LCD display with push buttons for door open intercommunicating call a
18. CESVK 1 ECLIPSE with additional intercom 19 07 2008 Titolo Data modifica I CESVK 1 ECLIPSE con citofono addizionale 08 04 2009 e Videx Electronics S p A Notes Hm adis WX Via del Lavoro 1 63020 Monte Giberto ap The bus termination of the videomonitor is open because is closed on the intercom that is connected on the bus after the videomonitor Marco Rongoni Phone 39 0734 631669 Fax 39 0734 631669 Note Cod File 7 www videx it info videx it La terminazione del bus sul videocitofono aperta perch chiusa sul citofono che collegato al bus dopo dei videocitofono esvk004 dwg ESVK 1 1S WITH ADDITIONAL VIDEOPHONE Li og Q E 5 Y Y 9 9 NE E 3 56 z 36 9 e ie 5 5 5 o lt a sE E Dik T Close i pe Close 42 eo it da N zZ O Extension N 1 Extension 2 Videophone N 1 Videophone N 1 bees E Se eg P Pn eee aot e Local Bell Local Bell N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system
19. L Videophone N 1 N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the Art 2324 programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on Art 2322 O BALANCE e L 12Vac D SE Title Data creazione Foglio CESVK 1 ECLIPSE plus codelock Art 4800 11 11 2009 1 1 Titolo Data modifica 11 11 2009 6 Videx Electronics S p A Notes Autore Via del Lavoro 1 63020 Monte Giberto AP e Phone 39 0734 631669 Fax 39 0734 631669 Marco Rongoni www videx it info videx it Note Cod File esvk013a dwg My VIDEX Factory Office VIDEX ELECTRONICS S p A Via del lavoro 1 63020 MONTEGIBERTO AP ITALY Phone 39 0734 631669 Fax 39 0734 632475 www videx it e mail info videx it Main UK office VIDEX SECURITY LTD 1 Osprey Trinity Park Trinity Way London E4 8TD Phone 44 0870 3001240 Fax 44 0208 5235825 www videx security com e mail info videx security com Northern UK office VIDEX SECURITY LTD Unit 4 7 Chillingham Industrial Estate Chapman Street NEWCASTLE UPON TYNE NE6 2XX Phone 44 0870 3001240 Tech Line 44 0191 224 3174 Fax 44
20. Made in Italy 123456 BE d S 4333 0 STEEL a 4333 1 ALI O x 2 25565592959 0000000000 5595666966 M v Q Fig 2 DESCRIPTION Speaker unit module with built in B amp W camera with autoiris lens comprised of IR illumination LEDs According to the speaker unit version it includes one or two call push buttons The module is available also in colour camera version where the illumination LEDs are white light The unit circuitry incorporates The transmitting amplifier with condenser microphone and volume control The receiving amplifier with volume control audio balance circuit with the BALANCE control enslavement relay to enable the electric lock 3 contacts common normally open and normally closed It can work also as capacitor discharge to supply directly the electric lock The call buttons from 1 to a maximum of 2 depending on the module version The illumination LEDs for the card name holder The camera comprised of illumination LEDs Module Details Camera with illumination LEDs Loudspeaker Card name holder Call push button 1 or 2 according to the model Operation LEDs Microphone Microphone volume control Balance Control Loudspeaker volume control Dip switch to carry out the following programming Door station ID switches from 1 to 3 Door opening time switch 4 Conversation time switch 5 k System connection terminals AVAILABLE MODULE VERSIONS
21. necessary to restart the system power off then power on Art 4333 1 to Art 5488 i Art 2321 Push to Exit Title CESVK 1 ECLIPSE Titolo Notes e Videx Electronics S p A Via del Lavoro 1 63020 Monte Giberto AP Phone 39 0734 631669 Fax 39 0734 631669 ms www videx it info videx it PrtCode ESVK ENG 1 6 Pag 31 44 25 11 2009 INS e a lx I IX y_ A C cO 00 NI DI N Z 2 2 Z 2 2 2 P Meno 123456 IRA O BALANCE e AE 12Vac Q SE 08 04 2009 modifica 08 04 2009 Rongoni Cod File esvk002 dwo Rev 1 6 1 9 07 2008 ESVK 2 TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT 90 SW3 20000000 SW2 2 Art 3980 S E _ Close R m Extension N 1 Videophone N 1 Local Bell L Art 2321 2 Art 4333 1D papur m Push to Exit IRA BALANCE Extension N 1 Videophone N 2 I I I I ST il Sul I Z LO I M I z Q O e e c t lt E E co A I LO P 1H Close x I co I CN I Z LO I I I L Local Bell iz nd N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripris
22. power Art 2321 off then power on O BALANCE Art 4333 1 I pig 12Vac QD SE 09 04 2009 1 1 23 10 2009 i no Via del Lavoro 1 63020 Monte Giberto AP Marco Rongoni www videx it info videx it SDesv kO 1 0 i dw O CESVK 1 1S ECLIPSE WITH ADDITIONAL VIDEOMONITOR N oO A N Co Extension N 1 Videophone N 1 H SM Art 4333 1 Local Bell a e to Art 9400 Art 2321 IX LX D X tn co NI DI VI A gt N c 2 2 2 2 2 2 STRA O BALANCE Art5488 Ta aT i DI 3 13 4S gu 5i i 15 6 is 7 2 i 8 ag 0 19 DI ES g Cm to Art 5488 Co Local Bell Extension N 2 Videophone N 1 Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on d 2Vac SE ata creazione Foglio 29 07 2009 11 11 2009 Marco Rongoni Cod File esvk011a dwa ESVK 1 1S PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPL
23. the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 23 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 2305 Extension Relay for VX2300 digital systems 87 50 65 00 N ouA ui 99 999 TTT TTT TI Art 2305 x ER LO o dp 2 0 0 Fig 1 Fig 2 DESCRIPTION This unit can be connected directly to the bus and has two operating modes general purpose extension relay and apartment extension relay for addi tional sounders As general purpose extension relay the built in relays are controlled by the relevant button of the intercom or videophone while as ex tension sounder relay relay one will operate on each ring and relay two will operate for the duration of the call CONNECTION TERMINALS amp DIP SWITCHES Description Input Output bus connection terminals Input Output bus connection terminals Relay 2 common contact Relay 2 normal
24. until the videophone h unlocks from the mounting plate SPECIFICATION Housing Mounting 5000 Series Videophones mounting plate plus connection board Push buttons Yes 6 Programming Yes carried out by the dip switches located on the rear of the videophone Controls Loudspeake and call tone volume brightness and hue Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 15 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 51 88 Hands Free Intercom for VX2300 go m x o o o o o 0000000 o o o o 0 O 0 0 O O O S o
25. 14 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series VIDEOMONITOR WALL MOUNTING INSTRUCTIONS Cables must be fed through the opening Fig 2A of the mounting plate which should be fitted approximately 135cm from finished floor level as shown in Fig 1 Place the mounting plate c against the wall feeding the wire group d through opening e of the mounting plate and mark the fixing holes a Fig 2A Drill the fixing holes a insert the wall plugs b then with the cables threaded through opening fix the mounting plate to the wall with the 4 screws provided Fig 2A Hook the pcb connection board g to the mounting plate cas shown in Fig2B and connect the wires using the screwdriver provided to the terminals as shown in the diagram provided Once the wires are connected hook the videophone h to the Mounting plate c as shown in Fig 3 e Connect the Plug I on the ribbon cable from the videophone to the plug T on the PCB connection board g Place the videophone h against the 4 hooks on the mounting plate in line with the 4 openings on the rear side of the videophone Fig 4 and push down as suggested by the pointers in Fig 3 the videophone will lock into place To remove the videophone hold it firmly and push the unit in an upward direction
26. 24 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 21 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 231 5 BUS booster and video signal amplifier AMPLIFICATION DESCRIPTION The Art 2315 restores the voltage levels of the BUS line and amplifies the video signal 3 levels H high M medium and L low The BUS line must be interrupted and connected to the BUS IN input then the signal from the BUS OUT will be amplified Connect to the PS input a power supply Art 2321 We suggest the use of the BUS booster in installations which are not using the VIDEX CM2 cable and it is necessary to reach large cables distances i e Using CAT5 distances greater than 70m CONNECTION TE
27. 59 lt DO Ea Ee 2000 20 2345678 DOZ Extension N 1 Videophone N 1 De I I I I I I I I I I I I I I I I I I I I I I I I I L Local Bell N B 0009 O 22202050 200 N Art 3980 20 00000000 Local Bell Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on gt Art 4333 1D Push to Exit Title ESVK CESVK 2 with additional door station and entrances exchanger Titolo IESVK CESVK 2 con posto esterno addizionale e scambiatore di ingressi Note Phone 39 0734 631669 Fax 39 0734 631669 Art 2321 IRA O BALANCE i JA 12Vac EL SE Art 2301N 3 Art 4333 1D IN4 Fare attenzione alle polarit della connessione tra alimentatore e scambiatore Take care to the polarity between the power supply and the exchanger IRA O BALANCE EM 12Vac EL SE 23 10 2008 25 11 2009 222 VN Via del Lavoro 1 63020 Monte Giberto AP Marco Rongoni www videx it inf
28. 8 ON Art 3980 Bus Termination SWI to Art 5408 Local Bell ILL 8 9Gg8rvrg2 l Extension N 1 Videophone N 1 Extension N 1 Videophone N 3 p Local Bell N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi Art 2321 e 3 e BUS N After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on Art 4333 1 I 12Vac p SE 1 5KOhm 1W 1 Title Data creazione Foglio ESVK Videokit with button expansion module video distributors and additional videophones 08 04 2009 Titolo Data modifica 1 1 ESVK Videokit con modulo d espansione pulsantiera distributori video e videocitofoni addizionali 22 04 2009 Via del Lavoro 1 63020 Monte Giberto Marco Rongoni Phone 39 0734 631669 Fax 39 0734 631669 Note Cod File esvk009 dwag PrtCode ESVK_ENG_1 6 doc Pag 34 44 25 11 2009 Rev 1 6 www videx it info videx it CESVK ESVK 2 WITH ADDITIONAL DOOR STATION AND ENTRANCES EXCHANGER TWO ENTRANCES SYSTEM 2 QI 20 2 0 DOE Q 20 g O o
29. F 0 multi i LJ on M orr ply each digit for the relevant decimal weight then sum values obtained to get the address E g as highlighted 11234567 ON ON in the table OFF ON OFF OFF ON OFF ON in binary is equal to 0100101 then multiplying each digit for the relevant decimal weight you obtain the address that is 37 SW1 eis Status 2 Binary Code Decimal Weight Ad 6 5 4 3 2 OFF O OFF OFF OFF OFF OFF OFF OFF 0 OFF ON OFF OFF ON OFF ON lov on on jov On on Jr v Tiu ae Note The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127 BUS TERMINATION SW1 8 The factory preset for this switch is ON termination enabled In case of more units intercoms videophones or video monitors in a parallel connection bus wires are connected to the terminals of the first unit then from this to the second and so on up to 4 units max switch 8 must be set to ON only for the last unit in the chain while on all other units must be set to OFF bus termination disabled This switch establishes the intercommunication mode in OFF position default intercommunication is between units in the same apartment same addresses but different extension in ON position the intercommunication is between units in different apartments different addresses On installations where there are m
30. ION SETTINGS Switches Status Intercommunication Mode Videophone i Extension switch 1 switches 2 3 Intercommunication between videophones in the same apartment To call an exten sion pick up the handset then press the door open button as many times as the ex tension Eg extension 2 two times 3 three times etc Each intercom videophone must have a different extension address the master address must always be set ie in a 3 intercom videophone installation one the _inter com videophone must have the extension address 1 while the others must have different addresses included from 2 to 4 Intercommunication between videophones in different apartments To call an exten sion pick up the handset then press the door open button as many times as the ad dress Eg extension 10 ten times 12 twelve times etc Slave Mode switch 4 for Extensions 2 3 and 4 KENNEN OFF Factory preset during a call the slave videophones will only ring while the master will also show the video picture The picture will only appear on the slave when answered During a call the videophone will ring and show the video picture in this case the videophone must be powered locally using an Art 2321 and connecting BUS to Vin 9 and BUS to 10 NOTE Extension 1 is mandatory On systems with more than one device in an apartment each device must have a unique extension ID On installations where there are more than one intercom videop
31. IVACY DURATION TIME 3s 2 switch 1 switches 2 3 3 2 The privacy duration time is set by switches 2 and 3 When enabled the privacy ser OFF vice will be disabled when the set time expires or the switch is moved back to off N Pe SW3 INTERCOMMUNICA TION SETTINGS mm 2 FSE switches 2 3 ON F F Intercommunication allowed between videophones same unit address inside the 1 master same flat To call an extension pick up the handset then press the door open button OFF ON as many times as the extension value Eg extension 2 two times 3 three times etc 2 Slave N No privacy time expiration the privacy service is enabled or disabled only by the slide switch OFF Each intercom videophone in the same apartment must have a different exten 3 slave sion address the master address must always be set except when one of the intercom videophone is set for apartment intercommunication i e in a 3 inter com videophone installation one of the intercom videophone must have the 4 Slave extension address 1 while the others must have different addresses Intercommunication allowed between videophones different apartment To call an OFF OFF ON extension pick up the handset then press the door open button as many times as the address value Eg extension 10 ten times 12 twelve times etc On installations where there are more than one intercom videophone in the same apartment and intercommunicatio
32. ORMATION PrtCode ESVK All Countries Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 The product is CE marked demonstrating its conformity and is for distribution within all member states of the EU with no restrictions This product follows the provisions of the European Directives 89 336 EEC amp 92 31 EEC 73 23 EEC LVD and 93 68 EEC CE marking ENG 1 6 doc Pag 6 44 25 11 2009 Two Wire Videokit ESVK Series Call expansion module Connect to GND terminal of Art 4333 Collegare al morsetto GND dell Art 4333 IRA BALANCE Art 4333 1 Art 4845 1 5KOhm 1W UK Customers VIDEX Security LTD www videx security com Tech Line 0191 224 3174 Fax 0191 224 1559 Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui to liberamente all interno dei paesi membri dell unione europea EU Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD e 93 68 EEC Marcatura CE Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 31 81 Digital intercom for VX2300 2 Wire System 85 BARA BARA REA NO NO NO MS 2 5 E LMS DESCRIPTION Intelligent intercom with door open intercommunicating call push button key bus relay Art 2305 activation button dot privacy ON OFF switch door open and privacy on LEDs an
33. RMINALS AND JUMPERS Terminal Jumper Description BUS IN BUS line input BUS OUT BUS line output Power supply input use Art 2321 AMPLIFICATION Video signal amplification 3 levels high medium and low SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push Buttons N A Programming N A Controls Video signal amplification 3 levels Power Supply Requires local 2321 PSU Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 22 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 2301 Entrances exchanger for VX2300 digital systems THY O OFT
34. Y TO THE CODELOCK 200 I I I l l x S Puls 5 CN 42 N z QI IS S S N I o e Es I gt o lt I 5 5 E c E Ee 5 gi Local Bell I Close L I n n N I Extension I L Videophone N 1 Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on Art 2321 Art 2322 ELA BALANCE Oa A ON 123456 Art 4333 1 JRH 12Vac QO SE Art 4800 Title Data creazione Foglio 11 11 2009 1 1 Titolo Data modifica 11 11 2009 6 Videx Electronics S p A Via del Lavoro 1 63020 Monte Giberto AP e Phone 39 0734 631669 Fax 39 0734 631669 Marco Rongoni esvk012a dwa www videx it info videx it CESVK 1 1S ECLIPSE PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK Bell Art 5488 Bi 2 13 I 2 14 is Lom 2 tg loss bd vi gi 22 M E I CN I I I Ts I I I eo to Art 9400 22 Extension N Local I I I
35. consists of the following settings Number of Rings Melody selection Unit address 1 127 switches 1 to 7 of SW1 Bus Termination open or close switch 8 of SW1 Intercommunication mode between apartments or within apartment switch 1 of SW3 Extension address 1 4 switches 2 3 of SW3 Slave mode switch 4 of SW3 Privacy duration switches 1 2 and 3 of SW2 The programming of the number of rings and melody are carried out through the videomonitor push buttons all other settings are carried out on the three dip switch banks SW1 SW2 SW3 the rear side of the video monitor Except the number of rings programming it is necessary to remove temporary the power supply after making any other programmin changes NUMBER OF RINGS AND MELODY SELECTION First of all make a camera recall to switch on the unit then proceed with the programming operation To alter the number of rings and select the melody the videomonitor must be in program mode This is achieved by operating the two following buttons at the same time left button of the volume control and the right button of the colour intensity control see Fig 1A 8 small buttons towards the bottom of the face plate far left button and far right button together When the programming mode is entered LED 1 Fig 1A starts flashing This will automatically reset after 20 seconds of idle time Number of rings When the programming mode press and hol
36. cy ON OFF button plus privacy on and door open LEDs Controls 3 levels of call tone volume both main and local plus contrast and brightness The videophone is available also in colour version Art 3481 which uses a 3 5 active matrix LCD monitor To reduce bus current all apartment devices are in a sleep mode when not used In case a user forgot to replace the handset each operation must be executed within 10 seconds of lifting the handset otherwise the handset returns to its sleep state To then perform an operation it would be necessary to hang up the handset and pick it upagain PUSH BUTTONS LEDS AND CONTROLS FIG 1 Door open push button Intercommunicating call For an intercommunicating call pick up the handset and press as many times as the extension or address value to call see SW3 Intercommunication Settings Camera recall push button Pick up the handset and press as many times as the DEVICE of the door station to switch on If the door station uses the Art 4303N plus the Art 4330N pressing this button during a conversation switches the video signal coming from the camera module to the video signal coming from the camera module input for external camera C Activate bus relay board Art 2305 push button To activate a bus relay pick up the handset and press as many times as the address value of the relay d Service push button ood e Privacy ON OFF push button The privacy duration time can be program
37. d call tone volume control 3 levels To reduce bus current all apartment devices are in a sleep mode when not used In case a user forgot to replace the handset each operation must be executed within 10 seconds of lifting the handset otherwise the handset re turns to its sleep state To then perform an operation it would be necessary to hang up the handset and pick it up again PUSH BUTTONS LEDS AND CONTROLS FIG 1 Door open push button Intercommunicating call For an intercommunicating call pick up the handset and press as many times as the extension or address value to call see SW3 Intercommunication Settings Activate bus relay board Art 2305 push button To activate a bus relay pick up the handset and press as many times as the address value of the relay Door Open LED Switched ON if the door is open Its operation depends on additional connections Privacy ON LED Switched ON when the privacy service is active Privacy ON OFF switch The privacy duration time can be programmed If the intercom is programmed for a specific privacy duration after the service is enabled to ON red LED ON the service will automatically turn off when the time expires Call tone volume control 3 levels DIP SWITCHES AND JUMPERS FIG 2 SW1 Switches from 1 to 7 are used for unit address from 1 to 127 binary coded Last switch 8 is not used Switches 1 2 and 3 are used to set privacy duration time Switch 4 is not used Switches 1 2 and 3 are used
38. d is for distribution within all member states of the EU with no restrictions This product follows the provisions of the European Directives 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking PrtCode ESVK ENG 1 6 Pag 19 44 25 11 2009 UK Customers VIDEX Security LTD www videx security com Tech Line 0191 224 3174 Fax 0191 224 1559 Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui to liberamente all interno dei paesi membri dell unione europea EU Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD e 93 68 EEC Marcatura CE Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 31 7 Four way distribution box Sy ES BUS OUT1 BUS OUT 2 BUS OUT3 BUS OUT 4 o Close O o Close o Close open lo B B3 B4 AMPLIFICATION T DESCRIPTION The unit distributes the bus signal to 4 outputs linked to videophones or intercoms The distributor has amplification levels low medium and high the amplification only effects the 4 outputs and not the loop through output The Art 317 also includes a bus isolation feature which isolates the Art 317 from the rest of the bus if there is a short on one of its outputs This prevents a short in an
39. d the 85 button LED 1 will stop flashing and LED 3 Fig 1A will start to flash showing the number of rings each flash 1 ring i e 6 flashes 6 rings Once the value of rings has been reached release the button Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Melody selection When in the programming mode press left or right call tone volume control buttons A press the left button to navigate backward or the right button to navigate forward in the melodies selection menu until the videomonitor plays the selected melody during the melody play the LED1 stops flash ing Before press again one of the two buttons to select previous left button or next right button melody wait for LED1 starts flashing again then press and hold pressed one button until the selected melody is played Once reached the required melody Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Notes The second melody increases its volume at each ring first ring starts at minimum volume level up to the maximum volume level on the last ring Are available 4 levels of volume if are set 6 rings the fourth the fifth and the sixth will be emitted at the maximum volume level VIDEOMONITOR ADDRESS SW1 1 7 The table above shows how to set the address of the videophone Considering that ON 1 and OF
40. ease note The peripherals must not require more than 100mA CONNECTION TERMINALS Terminal Jumper Description B US line inputs _ 12V 0V 12Vdc 100mA output SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push Buttons N A Programming N A Controls N A Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 28 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series General Directions for Installation CABLE TYPES AND CROSS SECTIONAL AREAS The VX2300 digital system can use several types of cables but depending on their specification w
41. ergised state if the call is cancelled or the user ends the call SPECIFICATION Housing Mounting 5 Module A Type DIN box DIN bar or directly to the wall Push Buttons N A Programming Yes carried out by the 8 way dip switch Controls N A Power Supply from the bus Working Temperature 10 50 C Dry contacts relay Max 24Vac dc 5A CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 C C The product is CE marked demonstrating its conformity and is for distribution within all prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 EEC amp 92 31 EEC EMC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 24 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 2380 Interface 2 Wire to 4 1 audio system 65 Art 2380 Interface 2 Wire bus to 4 1 audio system SW1 2345678 Fig 1 Fig 2 DESCRIPTION In
42. es for VX2300 digital system The 2321 can be used for systems with 1 entrance up to 20 users while the 2321 P is for systems with more than 1 entrance and up to 100 users CONNECTION TERMINALS AND JUMPERS Terminal Jumper Description Mains input BUS terminals BUS terminals only Art 2321 P Jumper to adjust the output voltage only Art 2321 P V1 Low V2 Medium V3 Maximum Set to maximum V3 when the unit is used together with 2301N otherwise leave in a low or medium position CONNECTION TO MAINS AND POWER SUPPLY MOUNTING INSTRACTIONS The system must be installed according to national rules in force in particular we recommend to Connect the system to the mains through an all pole circuit breaker which shall have contact separation of at least 3mm in each pole and shall discon nect all poles simultaneously The all pole circuit breaker shall be placed for easy access and the switch shall remain readily operable POWER SUPPLY INSTALLATION Remove the terminal side covers by unscrewing the retaining screws Fix the power supply to a DIN bar or directly to the wall using two expansion type screws Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams Check the connections and secure the wires into the terminals Replace the terminal covers and fix them using the relevant screws When all connections are made restore the mains
43. flat blade screwdriver connect the wires to the pcb connection board c as shown in Figure 4 according to the installation diagram provided Connect ribbon cable plug from the front plate into plug e on the pcb connection board as shown in Figure 5 Close the intercom by hooking the front plate g to the back plate h as described below Hook the top of the front plate g to the top of the back plate as shown by pointer A in Figure 6 Move the lower side of the front plate g towards the back plate h and press until the unit locks into the back plate of the intercom To open the intercom once installed firmly grasp the bottom sides of the front plate cover pull forward in an upward direction to separate the front cover from the back plate as in Figure 6 NB Please take care when opening to avoid damage remember that the ribbon cable connects the front plate to the back plate connector pcb SPECIFICATION Housing Mounting 5000 Series Intercoms direct wall mount Push buttons Yes 4 Programming Yes carried out by the dip switches located on the rear of the videophone Controls Loudspeaker and call tone volume Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 The product is CE marked demonstrating its conformity an
44. he video ON the video monitor will be switched on independently of the extension address in this case the video monitor must be supplied locally using a power supply Art 2321 and connecting respectively BUS to terminal 14 and BUS to terminal 11 of the pcb connection board provided with the Art 5980 If this switch is set to OFF default the privacy duration is defined by switches 2 and this switch is set to ON the privacy duration is unlimited and the service can be enabled or disabled only by the privacy button PRIVACY DURATION SW2 2 3 This set up requires that switch 1 is set to OFF VIDEOMONITOR CONNECTION BOARD ART 5980 565665966666 1008RoNA NNNONUOUOUUO SIGNAL ON CONNECTION TERMINALS Terminal Description Ground GND BUS1 Bus input BUS2 Businput S4 Terminal controlled by the S1 button close to GND until the button is pressed Auxiliary LED power supply input 12Vdc 2 Terminal controlled by the S2 button close to GND until the button is pressed GND Ground GND Ground LB Local bell input active low GND G LE LB o 5 Q n ly lee eu VAUX Auxiliary power supply input to be used when the switch 4 of SW3 is set to ON _ n O MIL M Alarm input not implemented yet se I TT PrtCode ESVK_ENG_1 6 doc Pag
45. hlighted in A 32567 the table OFF ON OFF OFF ON OFF ON in binary is equal to 0100101 then multiplying each digit for the rele vant decimal weight you obtain the address that is 37 SW1 TN er Binary Code Decimal Weight e 65 2 OFF OFF OFF OFF ON OFF OFF 0 OFF ON OFF OFF ON OFF ON l N AN ron D oN Pon ON MK ON po on Note The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127 Set switch 8 to OFF position INTERCOMMUNICATION MODE SW3 1 This switch establishes the intercommunication mode in OFF position default intercommunication is between units in the same apartment same addresses but different extension in ON position the intercommunication is between units in different apartments different addresses On installations where there are more than one intercom videophone in the same apartment and intercommunication between different apartments is required only one intercom videophone may be set with this function SW3 1 ON 5 3 2 SW3 3 OFF The other inter com videophones in the apartment must be set for local intercommunication with extension addresses 2 4 slaves From the inter com videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave extensions 2 4 will be able to intercommunicate with each othe
46. hone in the same apartment and intercommunication between different apartments is required only one intercom videophone may be set with this function SW3 1 ON 5 3 2 SW3 3 OFF The other inter com videophones in the apartment must be set for local intercommunication with extension addresses 2 4 slaves From the inter com videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave extensions 2 4 will be able to intercommunicate with each other PrtCode ESVK 1 6 Pag 10 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series VIDEOPHONE CONNECTION BOARD ART 3980 As 3000 series videophones also this version uses the Art 3980 connection board 29995959999 Remove RI resistor Door open LED ground signal input Alarm input not implemented Contacts for S service push button Linked together when the button is Ground signal bell contacts di ee 316 he N OO E o 1 77 o oo oo _ _ _vwd o osa TTOe__a__ NN SPECIFICATION Housing Mounting 3000 Series Videophones mounting plate plus connection board Push buttons Yes 5 Programming Yes carried out by the dip switches located on the rear of the videophone Controls Call tone volume contrast and brightness Power Supply Supplied by the
47. ill allow different distances up 400 meters maximum We do not recommend the use of shielded cables because of the high eddy capacitance It is also not advised to double up on cables as this will also increase the capacitance The following table specifies values of resistance capacitance and maximum distances achievable for several types of cables capacitance and resistance values are referring to 100 metres of cable Cable Type Section Resistance Ohm Capacity nF Maximum Distance meters 200m VIDEX CM2 075 7 7 7 14132 8 200m 5 UTP CW1308 2 448 49 dm rr Std Telephone Cable Twowire 2 2 6 Two wire Between the power supply and the furthest door station or between the power supply and the furthest videophone In case of projects where it is necessary to reuse existing cables that could be cabled together with mains or other power cables check in advance the practicability of the system if the system cables are cabled together with mains or other power cables the system is directly exposed to electro magnetic interference that may cause noises on audio video and lost of functionality over digital communications In case of use of cables not in conformity with above specification it is possible to experience deterioration of digital and video signals We suggest to use twisted cables with maximum resistance of 10 Ohm 100m for each wire between the farthest door station and the farthest video
48. ill illuminate when the privacy service is enabled If the unit is switched off keep this button pressed together with the speak button until the privacy LED switches ON Intercommunicating call button For an intercommunicating call when the intercom is in stand by press as many times as the extension or address value to call Door open button During a call operation of this button will activate the door open relay NO1 NC1 COM1 LED 4 will illuminate if terminal 6 has been connected to a door contact Programming LED LED relating to the operation of the answer switch off camera recall simplex button LED relating to the operation of privacy button LED relating to the operation of door open button powered from the connection terminal 2 amp GND 1 on the connection board Loudspeaker volume control Call tone volume control PROGRAMMING The intercom setup consists of the following settings Number of Rings Privacy duration Melody selection Unit address 1 127 switches 1 to 7 of SW1 Intercommunication mode between apartments or within apartment switch 1 of SW3 Extension address 1 4 switches 2 3 of SW3 Bus Termination JP1 jumper on connection board PrtCode ESVK 1 6 Pag 16 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series The programming of the number of rings melody and privacy duration are carried out through the intercom push buttons
49. king the privacy on LED and remove the short between terminals 13 and 14 The number of LED flashes will be 1 for 3 rings or 2 for 6 rings Each time this operation is carried out the number of rings is switched between the values 3 and 6 SW1 VIDEOPHONE ADDRESS mangi peg E NN Binary Code Decimal Weight Address Ls s 4 s 2 a e z Js OFF o 0 oO OFF ON OFF 0 10 O OFF OFF OFF OFF ON ON o fo 0 Hos DE E E e p The table above shows how to set the address of the videophone Considering that ON 1 and OFF 0 multiply each digit for the relevant decimal weight then sum values obtained to get the address E g as highlighted in the table OFF ON OFF OFF ON OFF ON in binary is equal to 0100101 then multiplying each digit for the relevant decimal weight you obtain the address that is 37 Note The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127 SW2 PRIVACY DURATION TIME i Privacy Mode Privacy Duration SLAIS switch 1 switches 2 3 4 foo E E E S e 4 3 2 1 NE The privacy duration time is set by switches 2 and 3 When enabled the privacy ser OFF vice is disable when the time set expires or the relevant button is pressed again 4 hours E ON No privacy time expiration the privacy service is enabled or disabled only by the pri prc ee vacy button SW3 INTERCOMMUNICA T
50. ll is made Privacy on off button If the monitor is switched on press and keep pressed this button for more than 3 seconds to enable disable the service The relative LED will illuminate when the privacy service is enabled If the monitor is switched off keep this button pressed together with the speak button Until the privacy LED switches ON Camera select button With a conversation in progress press to switch from door station camera to external camera requires Art 4330N and external camera and viceversa Intercommunicating call button For an intercommunicating call when the videomonitor is in stand by press as many times as the ex tension or address value to call Door open button During a call operation of this button will activate the door open relay NO1 NC1 COM1 LED 4 will illuminate if terminal 6 has been connected to a door contact 1 LED for programming purposes 2 LED relating to the operation of the answer switch off camera recall simplex button 3 LED relating to the operation of privacy button LED ae ese to the operation of door open button powered from the connection terminal 6 of Art 5980 d Loudspeaker volume control eee volume control A Call tone volume control Brightness control 1 Colour intensity control PrtCode ESVK 1 6 Pag 12 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series PROGRAMMING The videomonitor setup
51. low input 6 Alarm input not implemented yet 7 bee SNC 8 BUS2_ Bus input _ CT T_T e eEe eme o RZ e r gt _ r9 9 00000 2222 10 BUS1 Bus input PrtCode ESVK 1 6 Pag 18 44 25 11 2009 Rev 1 6 VNVIDEX ART 5188 INTERCOM WALL MOUNTING INSTRUCTIONS Fig 4 Fig 5 Two Wire Videokit ESVK Series Fig 6 As shown in Fig 1 looking at the rear of the intercom insert the tip of a flat blade screwdriver into one of the two openings Fig 1A then slightly move the screwdriver in an upward direction to release the front from the back plate and opening the intercom unit Fig 1B Take care The back plate of the intercom houses the pcb connection board which is normally connected to the pcb in the front of the intercom by the ribbon cable the ribbon cable should not be connected when first opened Place the back plate of the intercom against the wall at approximately 135cm Fig 2 above finished floor level then mark the fixing holes taking into account that the cable group a must feed into the opening b Fig 3 As shown in figure 3 fix the back plate of the intercom to the wall feeding the cable group a through opening b Using a
52. ly open contact Relay 2 normally closed contact Relay 1 common contact Relay 1 normally open contact Relay 1 normally closed contact DIP SW 8 way dip switch to set the relay operating mode PROGRAMMING The operating mode is set by switch 8 as shown below Note After making changes to the dip switch settings it is necessary to disconnect it from the bus or power the system down and then reconnect before the changes will take affect GENERAL PURPOSE EXTENSION RELAY SWITCH 8 OFF When the unit is set as general purpose extension relay switches 1 to 6 are used to set the relays addresses and activation times Relay 1 2 Relay 1 Relay 2 Addresses Time m wm NE Switch 7 is not used For example if switch 1 is set to ON and switch 2 is set to OFF addresses 3 amp 4 pressing the dot button on the intercom or double dot on the vid eophone 3 times will operate relay one while pressing 4 times will operate relay two EXTENSION SOUNDER RELAY SWITCH 8 ON When the unit is set in this mode switches from 1 to 7 8 is not used but set to on are used to set the address of the unit the address of the unit is set to the same address as the videophone or intercom it that apartment refer to intercom videophone SW1 settings When the apartment is called relay 1 will operate 4 times once for each ring while relay 2 will energise for the duration of the call Approx 60 sec onds The relays revert to the de en
53. med g Door Open LED Switched ON if the door is open Its correct operation depend from correct connection terminals 1 and 18 Call tone volume control 3levels o Call tone volume control 3 levels Contrast control left decrease right increase Brightness control left decrease right increase DIP SWITCHES AND SWITCHES FIG 2 Switches from 1 to 7 are used for unit address from 1 to 127 binary coded Last switch 8 is not used Switches 1 2 and 3 are used to set privacy duration time Switch 4 is not used Switches 1 2 and 3 are used for intercommunication settings Switch 4 is used to set the slave mode SW Impedance terminator The standard position is close When more videophones are connected in parallel from a videophone to an other and so on until the last it must be set to open for all the videophones except for the last following the connection order PrtCode ESVK ENG 1 6 Pag 9 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series PROGRAMMING After each programming operation carried out through dip switches or jumpers it is necessary to temporary disconnect the videophone from the BUS or from the power supply if locally powered NUMBER OF RINGS The number of rings can be set to 3 factory preset or 6 To change the number of rings proceed as follow Unplug the flat cable from the pcb connection board Put in short the terminals 13 and 14 Plug in the flat cable chec
54. n between different apartments is required only one intercom videophone may be set with this function SW3 1 ON SW3 2 OFF SW3 3 OFF The other inter com videophones in the apartment must be set for local intercommunication with extension addresses 2 4 slaves From the inter com videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave extensions 2 4 will be able to intercommunicate with each other NUMBER OF RINGS The number of rings can be set to 3 factory preset or 6 To change the number of rings proceed as follow Disconnect the power supply from the system Short the terminals LB and GND Reconnect the power supply to the system checking the privacy on LED and then remove the short between terminals LB and GND The number of LED flashes will be 1 for 3 rings or 2 for 6 rings Each time this operation is carried out the number of rings is switched between the values 3 and 6 SIGNALS ON CONNECTION TERMINALS Description Bus contacts Door open LED ground signal input Door open LED power supply input 12Vdc Ground signal Groundsignal GND Ground signal AL AL Alarm input not implemented Local Bell contact put a push button between this terminal and the relevant GND terminal SPECIFICATION Housing Mounting 3000 Series Intercoms direct wall mounting Push Buttons Yes two
55. nswer camera recall privacy on off BUS relay activation and 2 service buttons plus 4 LED s associated with 4 main buttons In addition to the above the unit has controls for loudspeaker volume call tone volume brightness and hue with programmable number of rings privacy duration and intercommunication mode PUSH BUTTONS LEDS AND CONTROLS FIG 1 Service push button When pressed shorts terminal S1 to terminal GND ground Bus Relay Button to Activate bus relay board Art 2305 To activate a bus relay press as many times as the address value of the relay Answer button On an incoming call operation of this button allows the user to answer and converse with the visitor LED 2 will illumi nate Camera recall button Press as many times as the DEVICE N of the door station to switch on Switch off button With the system switched on monitor on momentary operation of the button will switch the video monitor off The videomonitor will also automatically switch off after a time delay if the button is not pressed LED 2 will switch off Simplex button Pressing and holding the button for more than 3 seconds will switch the videomonitor into SIMPLEX speech mode Press and hold the button to speak to the caller LED 2 will flash rapidly release the button to listen LED 2 will flash slowly If the but ton is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when another ca
56. o videx it PrtCode ESVK_ENG_1 6 doc Pag 35 44 25 11 2009 Cod File spesvk005 dwo Rev 1 6 ESVK 1 WITH 3 ADDITIONAL VIDEOPHONES AND RELATIVE POWER SUPPLIES ALL MONITORS SWITCHED ON DURING THE CALL Art 2321 SW3 2022222222 SW2 Art 3980 Art 3980 Termination Termination SWI SWI 12345678 12345678 Extension 1 Videophone N 1 Extension N 2 Videophone N 1 Local Bell Local Bell Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on Art 2321 Art 4333 1 123456 Push to Exit Title ESVK 1 with 3 additional videophones and 3 additional power supplies Titolo ESVK 1 con 3 videocitofoni addizionali e 3 alimentatori addizionali Videx Electronics S p A X Via del Lavoro 1 63020 Monte Giberto ap The additional power supplies are required to switch on all the videophones during the call Phone 39 0734 631669 Fax 39 0734 631669 Note Ao MM NOE www videx it info videx it Gli alimentatori addizionali sono richiesti per accendere contemporaneamente alla chiama
57. of times the button is pressed each flash 15 minutes i e 8 flashes 2 hours Once the duration required has been reached release the X button Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Melody selection When in the programming mode press left or right call tone volume control buttons A press the left button to navigate backward or the right button to navigate forward through the melodies selection menu After each press the melody will be played during the melody play the LED1 stops flash ing Before pressing again one of the two buttons to select previous left button or next right button melody wait for LED1 to start flashing again then press and hold one button until the selected melody is played Once the required melody is reached Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Notes The second melody increases its volume at each ring first ring starts at minimum volume level and adjusts up to the maximum volume level on the last ring There are 4 volume levels Rings after this will all play at full volume INTERCOM ADDRESS SW1 1 7 The table above shows how to set the address of the videophone Considering that ON 1 and OFF 0 multi ply each digit for the relevant decimal weight then add values obtained to get the address E g as hig
58. ore VN Via del Lavoro 1 63020 Monte Giberto ap Ne bus termination of the videomonitor is open because is closed on the intercom that is connected on the bus after the videomonitor Marco Rongoni Phone 39 0734 631669 Fax 39 0734 631669 Note Cod File www videx it info videx it La terminazione del bus sul videocitofono aperta perch chiusa sul citofono che collegato al bus dopo dei videocitofono esvk003 dwo PrtCode ESVK_ENG_1 6 doc Pag 37 44 25 11 2009 Rev 1 6 CESVK 1 1S ECLIPSE WITH ADDITIONAL INTERCOM Videophone N 1 Bell Intercom N 1 Art 5488 i on 2 u is lont A Loss Bir ous 18 219 0120 E 5 I X I I l 4 to ArL400 lt 2 ss Extension N 1 Local Extension N 2 I I I I I N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema Art 2321 ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on LY O BALANCE e A aba 123456 Art 4333 1 Push to Exit Bel 12Vac SE Title Data creazione Foglio
59. ore than one intercom videophone in the same apartment and intercommunication between different apartments is required only one intercom videophone may be set with this function SW3 1 ON 5 3 2 SW3 3 OFF The other inter com videophones in the apartment must be set for local intercommunication with extension addresses 2 4 slaves From the inter com videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave extensions 2 4 will be able to intercommunicate with each other PrtCode ESVK 1 6 Pag 13 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series EXTENSION NO SW3 2 3 If the intercommunication between apartments is enabled switch 1 of SW3 ON leave these two switches in default position both to OFF Otherwise if the intercommunication is between the same apartment switch 1 of SW3 OFF set the extension addresses starting always from 1 During the ex ternal call all video monitors in the same flat will ring but the video will be shown only from the videmononitor with extension address 1 1 default master OFF 2 slave OFF ON slave 4 slave SLAVE MODE SW3 4 This set up concerns the answering mode of the video monitor when there is more than one unit max 4 in the same apartment OFF default during a call only the video monitor with extension 1 master will show t
60. phone and maxi mum capacitance of 40nF this value must be computed considering all the cables used in the system the capacitance metres value is normally speci fied on the cable package or directly on the cable BUS DEVICES SETUP AND VIDEO DISTRIBUTION Any device on the system door station intercom videophone relay etc for which the programming is carried out through one or more dip switches to store the new setup must be disconnected from the power supply for 1 minute at least When have more than one device in the same apartment all the devices must be connected to the same video distributor Art 317 this means that you cannot use two video distributors Art 318 for one apartment where you have 4 videophones intercoms HOW TO CONNECT LOCAL POWER SUPPLY The drawing below shows how to connect a local power supply when required i e when you have 4 videophones with the same address that must be switched on at the same time In both cases switch 4 of SW3 must be set to the ON position NOTE OBSERVE CONNECTION POLARITIES AS SHOWN IN THE DIAGRAM BELOW Art 5488 2 0 Q QO 00000222 Z 0000000000 Art 3980 Termination W1234567 8 8123 4 41 234 a Ve eye Extension N 1 Extension N 1 Videophone N 1 Videophone N 1 Art 2321 Art 2321 PrtCode ESVK 1 6 Pag 29 44 25 11 2009 Rev 1 6 ESVK 1 ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT Termination Close L
61. r EXTENSION NO SW3 2 3 If the intercommunication between apartments is enabled switch 1 of SW3 ON leave these two switches in default position both to OFF Otherwise if the intercommunication is between the same apartment switch 1 of SW3 OFF set the extension addresses starting always from 1 1 default master 2 slave 3 slave 4 slave Notes Set switch 4 to OFF position PrtCode ESVK 1 6 Pag 17 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series BUS LINE TERMINATION JP1 The factory preset for this jumper is A position termination enabled In case of more units intercoms videophones or video monitors in a parallel con nection bus wires are connected to the terminals of the first unit then from this to the second and so on up to 4 units max JP1 must be set to A position only for the last unit in the chain while on all other units must be set to B position bus termination disabled In case of units of different type video phones video monitor hands free or standard intercoms etc remains fixed the rule that the bus termination must be enabled only on the last unit in or der of connection INTERCOM CONNECTION BOARD 1 2 3 4 5 6 T 8 9 q c U A SIGNAL ON CONNECTION TERMINALS Terminal Description 1 GND Ground 2 LED Auxiliary LED 12Vdc Input 3 eci 4 ez ee l 5 Local bell active
62. ta tutti i videocitofoni PrtCode ESVK_ENG_1 6 doc Pag 36 44 25 11 2009 Art 2321 Termination Extension N 3 Videophone N 1 BALANCE Art 2321 Art 3980 Termination SWI SWI 812345078 ON 12345678 ON Extension N 4 Videophone N 1 Local Bell Lc Local Bell EI 12Vac_ p SE 19 07 2008 08 04 2009 Marco Rongoni Cod File esvk006 dwg Rev 1 6 CESVK ESVK 1 WITH ADDITIONAL INTERCOM e e 2 SW3 DOOD 0 0 2 2 SW2 41234 ON ON Art 3980 Termination SW1 Close 412345678 ON Extension N 1 Videophone N 1 Extension N 2 ___IntercomN 1 2 Local Bell fc i N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device Art 2321 connected to the system it is necessary to restart the system power off then power on 123456 n N lt Push to Exit AE 12Vac SE Title Data creazione Foglio ESVK 1 Videokit with additional intercom 19 07 2008 Titolo Data modifica ESVK 1 Videokit con citofono addizionale 08 04 2009 e Videx Electronics S p A Notes cen Aut
63. terface to connect 4 1 audio devices to the VX2300 2 Wire Bus For example the Art380 telephone interface or the Art275 PABX interface Using the items listed above 380 275 it is possible to use a conventional household telephone as a standard intercom The operating mode of the telephone depends on the connected device and on the connections made refer to the instructions of the Art 380 or Art275 DIP SWITCHES AND JUMPERS FIG 1 Switches from 1 to 7 are used for unit address from 1 to 127 binary coded Last switch 8 is not used Switches 1 2 and 3 are used to set privacy duration time Switch 4 is used to set the Priv signal operating mode Switches 1 2 and 3 are used for intercommunication settings Switch 4 is not used 517 Impedance terminator The jumper must be normally closed When more videophones intercoms are connected in parallel pe ripheral to another and so on until the last the jumper must be open for all the intercoms except for the last following the order of connec tion PROGRAMMING After each programming operation carried out through dip switches or jumpers it is necessary to temporary disconnect the device from the BUS or from the power supply if locally powered SW1 DEVICE ADDRESS Switches Status Binary Code Decimal Value 7 6 5 4 3 2 1 64 32 6 a 4 2 1 Code OFF OFF OFF OFF_ OFF JON o Jo 0 o 10 0 J o Jo o 1 O o 0 1 oF o
64. tinarla affinch le variazioni vengano recepite dai rispettivi dispositivi After each change on the programming of the door station videophone or any other device connected to the system it is necessary to restart the system power off then power on PER 2Vac SE Title Data creazione Foglio ESVK 2 ESVK 25 Two way Easy Videokit 19 07 2008 1 1 Titolo Data modifica ESVK 2 ESVK 25 Easy Videokit bifamiliare 18 07 2008 Videx Electronics S p A Ness Autore Via del Lavoro 1 63020 Monte Giberto AP RED Marco Rongoni Phone 439 0734 631669 Fax 39 0734 631669 Note Cod File www videx it info videx it esvk007 dw 9 PrtCode ESVK ENG 1 6 Pag 32 44 25 11 2009 Rev 1 6 CESVK 2 ECLIPSE TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT n 4 1 4 a Extension N 1 Videophone N 2 Extension N 1 Videophone N 1 Art 5488 ZE Art 5488 DI DI PEN I I 3 si 13 2 u 4 2 14 2 45 x 2 15 2 6 2 1 7 s d 2 ig 2 19 2 19 2 y 0 22 Q A pi I I to 1 2498 cm to ArL5400 Local Bell Co Local Bell N B Dopo ogni cambiamento nella programmazione del posto esterno del videocitofono o del rel necessario togliere l alimentazione al sistema e ripristinarla affinch le variazioni vengano recepite dai rispettivi dispositivi
65. to for intercommunication settings Switch 4 is not used Impedance terminator The jumper must be normally closed When more videophones intercoms are connected in parallel from a pe ripheral to another and so on until the last the jumper must be open for all the intercoms except for the last following the connection or PROGRAMMING SW1 INTERCOM ADDRESS After each programming operation carried out through dip switches or jumpers it is necessary to temporary disconnect the phone from the BUS or from 6 5 4 3 2 OFF OFF OFF OFF O o i Co i i i the power supply if locally powered Binary Code Decimal Value Decimal Code OFF OFF OFF OFF OFF 2 o fo OFF o fo OFF oF OFF oF o ON o fo DO e 10 10 AE The table above shows how to set the address of the phone Considering that ON 1 and OFF 0 multiply each digit for the relevant decimal weight then add values obtained to get the address E g as highlighted in the table OFF ON OFF OFF ON OFF ON in binary is equal to 0100101 then adding each digit for the relevant decimal weight you obtain the address 37 Note The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127 PrtCode ESVK ENG 1 6 Pag 7 44 25 11 2009 Rev 1 6 7 MIVIDEX Two Wire Videokit ESVK Series SW2 PR
66. tting when the Art 2380 is in a parallel same address connection with other devices it must be linked to terminal two SPECIFICATION Housing Mounting 9 Module A Type DIN box Push Buttons N A Programming Yes carried out through dip switches Controls N A Power Supply Supplied from the BUS Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all Il prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee 89 336 amp 92 31 EEC 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking 73 23 EEC LVD e 93 68 EEC Marcatura CE PrtCode ESVK 1 6 Pag 26 44 25 11 2009 Rev 1 6 NVNVIDEX Two Wire Videokit ESVK Series Art 2321 2321 P Power supplies for VX2300 Iz a z L3 Ra 001 385 DESCRIPTION These two units are specific power suppli
67. y one apartment compromising the whole system CONNECTION TERMINALS AND JUMPERS Description Bus input terminals Bus output terminals loop through to next distributor Videophone Intercom bus output 1 Videophone Intercom bus output 2 Videophone Intercom bus output 3 Videophone Intercom bus output 4 Close Open bus output jumper for BUS OUT 1 Move to close when BUS OUT 1 is not used B2 Close Open bus output jumper for BUS OUT 2 Move to close when BUS OUT 2 is not used Close Open bus output jumper for BUS OUT 3 Move to close when BUS OUT 3 is not used SPECIFICATION Housing Mounting Plastic box 70x110x30mm direct wall mounting Push Buttons N A Programming N A Controls Outputs amplification 3 levels Power Supply Supplied by the BUS line Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows the provisions of the European Directives Questo prodotto conforme alle direttive Europee
68. y out systems up to 8 entrances linking together two 2301N observe the polarities when connect ing the BUS output of the first exchanger to the AUX of the second BUS with AUX and BUS with AUX Door station input 1 the signal may be amplified by the relative jumper L Low M Medium and H High Door station input 2 the signal may be amplified by the relative jumper L Low M Medium and H High Door station input 3 the signal may be amplified by the relative jumper L Low M Medium and H High Door station input 4 the signal may be amplified by the relative jumper L Low M Medium and H High SPECIFICATION Housing Mounting 9 Module A Type DIN box DIN Bar or directly to the wall Push Buttons N A Programming N A Controls Signal amplification on 3 levels for each bus input Power Supply From specific power supply or from the bus Working Temperature 10 50 C CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A VIDEX Security LTD www videx it technical videx it www videx security com Tel 39 0734 631669 Tech Line 0191 224 3174 Fax 39 0734 632475 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution within all prodotto marchiato CE a dimostrazione della sua conformit e pu essere distribui member states of the EU with no restrictions to liberamente all interno dei paesi membri dell unione europea EU This product follows

Download Pdf Manuals